• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1603
  • 689
  • 348
  • 186
  • 180
  • 93
  • 71
  • 54
  • 46
  • 32
  • 19
  • 18
  • 11
  • 10
  • 7
  • Tagged with
  • 3975
  • 574
  • 489
  • 467
  • 464
  • 428
  • 404
  • 399
  • 370
  • 360
  • 331
  • 315
  • 311
  • 306
  • 306
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1521

Estudo dos canais alveolares superiores e do canal infra-orbital por meio da tomografia computadorizada de feixe cônico / Study of the superior alveolar canals and infraorbital canal using cone beam computed tomography

Laura Ferreira Pinheiro Nicolielo 23 August 2013 (has links)
Para oferecer mais informações aos cirurgiões no planejamento de intervenções cirúrgicas maxilofaciais, o presente estudo teve como objetivo avaliar a presença, localização e tamanho dos canais alveolares superiores (CAS), anterior (CASA) e posterior (CASP), canal infra-orbital (CI) e forame infra-orbital (FI) em imagens de tomografia computadorizada de feixe cônico (TCFC) de 100 pacientes adultos (&#x2265; 20 anos), obtidas pelo aparelho i-CAT Classic®. Um examinador calibrado observou a presença dos CAS, CI e FI bilateralmente. Quando presentes, eram medidos comprimento (parte descendente, parte do assoalho da órbita e total), largura e altura do CI; altura, largura e distância ao rebordo inferior da órbita (RIO) do FI; distância da borda inferior dos CAS a crista do rebordo alveolar em 5 regiões: canino (CAN), primeiro pré-molar (1PM), segundo pré-molar (2PM), primeiro molar (1M) e segundo molar (2M); e os diâmetros dos CAS. Foram também observados a localização dos CAS em relação ao seio maxilar e a presença de reparos anatômicos como canal duplo/múltiplo, anastomose intra-óssea e extensão do CASA para a abertura piriforme. Associações entre homens e mulheres, lados direito e esquerdo e regiões foram investigadas para todas as medidas e visibilidade, utilizando separadamente os métodos estatísticos. A presença do CI e FI foi de 100%. A visibilidade do CASA/CASP foi de: 99%/0% (CAN), 99%/21% (1PM), 89%/41% (2PM), 46%/44% (1M) e 7%/61% (2M). As médias dos comprimentos da parte descendente, da parte do assoalho da órbita e total do CI foram de 8,82mm, 19,44mm e 28,35mm, respectivamente. Altura e largura médias do CI foram, respectivamente, 2,08mm e 3,91mm. As médias da altura, largura e distância ao RIO do FI foram: 4,43mm, 5,18mm e 7,52mm, respectivamente. As distâncias médias do CASA ao rebordo alveolar foram: 18,54mm (CAN), 25,47mm (1PM), 28,43mm (2PM), 30,78mm (1M) e 33,21mm (2M); e do CASP: 22,3mm (1PM), 17,65mm (2PM), 15,34mm (1M) e 16,87mm (2M). As médias dos diâmetros do CASA e do CASP foram 0,90mm e 0,83mm, respectivamente, sendo que 77,5% dos CASA e 82% dos CASP eram &#x2264; 1mm e 22,5% dos CASA e 18% dos CASP eram entre 1-2 mm. Em relação ao seio maxilar, 53% e 44% dos CASA foram encontrados no terço superior e médio, respectivamente, e 64% e 36% dos CASP foram encontrados no terço inferior e médio, respectivamente. Houve diferença estatisticamente significativa (p<0,05) entre homens e mulheres para o comprimento, altura e largura do CI; para a altura, largura e distância ao RIO do FI; e para as distâncias dos CAS ao rebordo alveolar. CASA duplo, anastomose intra-óssea e extensão do CASA para a abertura piriforme foram detectados em 24,5%, 38,5% e 84% dos casos, respectivamente. A localização da anastomose foi teve maior ocorrência entre o CAN e 1PM (43%). Os resultados sugerem que a TCFC seja uma ferramenta adequada para examinar os CAS, CI e FI no planejamento de procedimentos cirúrgicos do terço médio da face, a fim de evitar danos a estruturas neurovasculares importantes. / To provide more information to clinicians in planning maxillofacial surgical interventions, the present study evaluated the presence, location and size of the superior alveolar canals (SAC), anterior (ASAC) and posterior (PSAC), infraorbital canal (IC) and infra-orbital foramen (IF) in cone beam computed tomography (CBCT) of 100 adult patients (&#x2265; 20 years old), obtained by i-CAT Classic®. One calibrated examiner observed SAC, IC and IF presence, bilaterally. When present, were measured: length (descending part, orbital floor part and total), width and height of the IC, height, width and distance from the IF to the inferior orbital rim (IOR), distance from the lower border of SAC to the alveolar crest in 5 regions: canine (CAN), first premolar (1PM), second premolar (2PM), first molar (1M) and second molar (2M); and the diameters of SAC. It was also observed the location of SAC in relation to the maxillary sinus floor and the presence of anatomical landmarks such as doble/multiple canal, intraosseous anastomosis and ASAC extension to the piriform aperture. Associations between men and women, right and left sides and regions were investigated for all measurements and presence using statistical methods separately. The presence of the IC and IF was 100%. The presence of ASAC/PSAC was: 99%/0% (CAN), 99%/21% (1PM), 89%/41% (2PM), 46%/44% (1M) e 7%/61% (2M). The mean lengths of the IC descending part, IC orbital floor part and total lenght of the IC were 8.82mm, 19.44mm and 28.35mm, respectively. The mean height and width of the IC were, respectively, 2.08mm and 3.91mm. The mean height, width and distance to the IOR of IF were: 4.43mm, 5.18mm and 7.52mm, respectively. The mean distances of ASAC to the alveolar crest were: 18.54mm (CAN), 25.47mm (1PM), 28.43mm (2PM), 30.78mm (1M) and 33.21mm (2M); and of PSAC: 22.3mm (1PM), 17.65mm (2PM) 15.34mm (1M) and 16.87mm (2M). The mean diameters of ASAC and PSAC were 0.90mm and 0.83mm, respectively, and that, 77.5% of ASAC and 82% of PSAC were &#x2264; 1mm and 22.5% of ASAC and 18% of PSAC were between 1-2 mm. In relation to the maxillary sinus, 53% e 44% of the ASAC were found in the upper and middle third of maxillary sinuses, respectively, and 64% and 36% of the PSAC were found in lower and middle third, respectively. There was a statistically significant difference (p<0.05) between men and women for the length, height and width of the IC, for the height, width and distance to the IOR of IF, and for distances of SAC to the alveolar crest. Double ASAC, intraosseous anastomosis and ASAC extension to the piriform aperture were present in: 24.5%, 38.5% and 84% of the cases, respectively. The location of the anastomosis had more incidence between the CAN and 1PM (43%). The results suggest that CBCT is a suitable tool to evaluate the SAC, IC and IF, assisting surgeons in planning surgical procedures of the midface, in order to avoid damage to important neurovascular structures.
1522

Interferência dos artefatos de imagem causados por acessórios ortodônticos metálicos em sobreposições de imagens de TCFC / Influence of streaking artifacts due to metallic orthodontic accessories in CBCT 3D model superimposition

Fernando Penteado Lopes da Silva 06 July 2012 (has links)
O objetivo deste estudo foi avaliar, de forma quantitativa e qualitativa, se artefatos de imagem causados por acessórios ortodônticos metálicos interferem em sobreposições tridimensionais (3D) de imagens de Tomografia Computadorizada de Feixe Cônico (TCFC). Dez crânios secos humanos foram submetidos a três aquisições tomográficas: sem acessórios ortodônticos (T1), com braquetes e tubos ortodônticos de aço inoxidável colados às superfícies vestibulares dos dentes superiores e inferiores (T2), e com fios ortodônticos de aço inoxidável inseridos nas canaletas dos referidos acessórios (T3). Os arquivos DICOM originais foram convertidos em arquivos de imagem Analyze, por meio do software Medsquare. O passo seguinte constituiu-se no registro rígido entre os pares de imagens T2-T1 e T3-T1, por meio do software Bioimage. Após o registro, foram então realizadas as sobreposições 3D entre os referidos pares de imagens, utilizando-se o software MeshValmet. Este software realiza uma codificação por mapas de cores, a partir das distâncias obtidas durante o processo de sobreposição. Distâncias positivas são codificadas com tonalidades de vermelho, enquanto que as negativas recebem tonalidades de azul. A ausência de deslocamento entre estruturas sobrepostas recebem o valor 0,0mmm sendo codificadas com a cor verde. As imagens referentes a T2 e T3 foram sobrepostas em relação à T1 no mesmo plano de espaço, para cada crânio da amostra. A partir das referidas sobreposições, foram calculadas as seguintes medidas: Distâncias Máxima, Mínima e Média, Distância Mean Square (MSD), Distância Root Mean Square (RMS) e Mediana. Estas quatro últimas caracterizaram-se como medidas de tendência central, e representaram a faixa de valores de maior concentração de dados. Os acessórios metálicos causaram artefatos de imagem principalmente nas imagens T2 e T3, porém os mesmos não comprometeram o processo de sobreposição das mesmas em relação à T1. As Distâncias Máximas foram comparadas à medida Diagonal (D), calculada a partir das dimensões dos acessórios ortodônticos e representativa dos mesmos (D=7,5mm). Nesta comparação, o teste t de Student não mostrou diferença significativa (p 0,05) indicando, de forma numérica, que os artefatos não se mostraram estatisticamente importantes em relação às dimensões dos corpos metálicos que os causaram. As medidas de tendência central foram então comparadas ao valor 0,0mm, o qual representa ausência total de deslocamento entre as imagens sobrepostas. Neste caso, o teste t também não evidenciou diferença significativa (p 0,05), indicando que a maior concentração de distâncias entre pontos em T2-T1 e T3-T1 localizou-se próxima ao referido valor. Somado a isso, a avaliação qualitativa propiciada pelas imagens corroborou tal constatação. Na comparação entre as medidas em T2-T1 e T3-T1, os coeficientes de Pearson mostraram alta correlação em relação às medidas de tendência central, como Distância Média (r=0.86), MSD (r=0.87), RMS (r=0.97) e Mediana (r=0.74). Mediante a avaliação quantitativa, complementada pela interpretação qualitativa dos dados, concluiu-se que os artefatos de imagem não comprometeram o procedimento de sobreposição de modelos 3D no presente estudo. / The aim of this study was to determine whether the artifacts caused by orthodontic metallic accessories interfere with the accuracy of three-dimensional (3D) Cone Beam Computed Tomography (CBCT) model superimposition. Ten dry human skulls were subjected to 3 CBCT scans: without orthodontic brackets (T1), with stainless steel brackets bonded (T2) and with orthodontic arch wires inserted into the bracket slots (T3). Individual 3D surface models were generated for the T1, T2 and T3 images, and the within-surface distances between T2-T1 and T3-T1 were computed. Superimposition error was calculated assuming CBCT image registration of T2 and T3 with respect to T1 using plain superimposition. The following measures were evaluated: Maximum, Mean and Mean Square Distance (MSD), Root MSD (RMS) and Median. The metallic accessories caused image artifacts primarily in T2 and T3 images which, however, did not compromise the 3D model superimposition. The maximum distances of artifacts image points were compared to the representative measure of orthodontic accessories (7.5mm), and Student t test showed no significant differences (p0.05) between both measures. When measures of T2-T1 and T3-T1 were compared, the Pearson coefficients showed a high correlation regarding the central tendency measures, as follows: Mean Distance (r=0.86), MSD (r=0.87), RMS (0.97) and Median (r=0.74). The statistical findings, which were complemented by qualitative image data obtained from this study, depicted that streaking artifacts did not affect the accuracy of CBCT 3D model superimposition of dry human skulls.
1523

Avaliação da morfologia craniofaciall de indivíduos com deformidades dentofaciais de classe III por meio de tomografias computadorizadas de feixe cônico / Evaluation of the craniofacial morphology of subjects with dentofacial Class III deformities using cone beam computed tomography

Hiroshi Miasiro Junior 03 April 2009 (has links)
A deformidade dentofacial de Classe III está associada a importantes alterações funcionais, psicológicas e estéticas. O objetivo neste trabalho foi avaliar a morfologia craniofacial de indivíduos adultos, com deformidades dentofaciais de Classe III comparando-os com um grupo de indivíduos com faces equilibradas com finalidade de diagnóstico e prognóstico ortodôntico e cirúrgico. Foram avaliados 50 indivíduos, os quais foram submetidos ao exame de tomografia computadorizada de feixe cônico (i- Cat®/ Cone beam 3-D Dental Imaging System, Imaging Sciences International, Hatfield, USA) com o propósito de avaliação e diagnóstico. A amostra foi dividida em dois grupos, sendo 25 indivíduos com equilíbrio das relações faciais e oclusão dentária excelente e 25 com maloclusão Classe III sendo que estes fazem parte da clínica de preparo ortodôntico para Cirurgia Ortognática da Faculdade de Odontologia da FOUSP. Após a obtenção dos arquivos digitais foram realizadas as reconstruções das imagens em três dimensões nos softwares Dolphin 3D® (Dolphin Imaging and Management Solutions, Chatsworth, CA EUA) e Maxilim® (Medicim- Medical Image Computing, Mechelen-Bélgica). Seqüencialmente foram demarcados pontos de referência anatômica e a seguir foram mensuradas grandezas lineares angulares e proporcionais que foram representadas, após avaliação estatística, por média e desvio padrão. Para determinação do erro do método foram calculadas as correlações intraclasses para avaliação da concordância e a fórmula de Dahlberg. Para comparação entre os grupos foi aplicada a Análise de Variância (ANOVA) com dois fatores, destinada a representar a oclusão e gênero. No caso de ocorrência de interação estatisticamente significativa foram realizadas comparações múltiplas de Tukey para verificar em qual dos gêneros dentro de cada grupo ocorreu diferença. O nível de significância adotado foi o de 5%. Com relação ao erro do método foi observada alta reprodutibilidade na avaliação intraoperador nos softwares Dolphin 3D® e Maxilim®. Na comparação cefalométrica 3D entre os grupos avaliados, foram observadas diferenças significativas (p<0,05), sendo que o grupo com deformidades dentofaciais Classe III demonstrou variações para o relacionamento entre altura e largura facial, associada ao aumento da porção inferior da face; rotação horária da mandíbula relacionada à maior inclinação do corpo e do ramo mandibular e pelo predomínio da altura facial anterior em relação à posterior; diminuição do comprimento e do ângulo da base craniana; compensação na altura alveolar da maxila; predominância da dimensão mandibular na configuração ânteroposterior do esqueleto facial e tendências compensatórias verticais que reduziram ao nível alveolar, os desequilíbrios esqueléticos estruturais. / Class III dentofacial deformity is associated with important functional, psychologic and aesthetics changes. The objective of this study was to evaluate the craniofacial morphology of adults, with Class III dentofacial deformity comparing them with a group of subjects with harmonious faces for diagnosis and prognosis in orthodontic and surgical cases. This study evaluated 50 subjects that were submitted to the cone beam computed tomography (i-Cat®/ Cone beam 3-D Dental Imaging System, Imaging Sciences International, Hatfield, USA) with the purpose of diagnosis. The sample was divided in two groups, one with 25 subjects with harmonious faces and excellent occlusion and another with 25 subjects with Class III malocclusion, that are in treatment in the orthodontic clinic for orthognathic surgery in the Faculty of Dentistry of University of São Paulo. After the digital archives were obtained, the 3D reconstruction of images were performed with the softwares Dolphin 3D® (Dolphin Imaging and Management Solutions, Chatsworth, CA EUA) and Maxilim® (Medicim- Medical Image Computing, Mechelen-Bélgica). After demarcation of the reference points, linear, angular and proportional measurements were made and represented in statistical analysis, by mean and standard deviation. To determine the error of method, intraclass correlations were calculated, and Dahlbergs formula was used. To compare both groups the Variance Analyses was applied (ANOVA) with two factors, representing occlusion and gender. When statistical significant differences were observed, Tukeys multiple comparison was performed to evaluate in which gender the variance happened. The level of significance adopted was 5%. The error of method showed high reproducibility for intra-operator evaluation in Dolphin 3D® and Maxilim® softwares. Cephalometric 3D evaluation of the groups, showed significant differences (p<0,05), and the group with Class III dentofacial deformity showed changes in the relationship of height and width, associated with an augmented height of the lower face; clock-wise rotation of the mandible related to an increase of the inclination of the mandible body and ramus and a greater anterior facial height in relation to the posterior facial height; decrease in the size and angulation of the cranial base; compensation in height of dentoalveolar maxilla; predominant mandibular size in anterior-posterior configuration of the facial skull and vertical dentoalveolar compensations that reduced to alveolar level the structural skeletal unbalance.
1524

Foraminas acessórias da região anterior da maxila em tomografia computadorizada de feixe cônico / Additional foraminas in anterior maxilla through cone beam computed tomography

Carla Renata Sanomiya Ikuta 27 October 2017 (has links)
Por meio do exame tridimensional de Tomografia computadorizada de feixe cônico (TCFC) é possível avaliar a área de interesse previamente aos procedimentos com maior precisão. As variações anatômicas são estruturas que devem ser consideradas para a realização de cirurgias, como a foramina acessória da região anterior da maxila (FARAM). O objetivo principal do presente estudo foi avaliar a FARAM, em 150 exames de TCFC, obtidas no aparelho ICat Classic®. Por meio do programa ICat Vision® foram mensuradas o diâmetro, a distância da FARAM ao forame incisivo (FARAM-FI), da FARAM ao rebordo alveolar vestibular (FARAM-RAV) e da FARAM a sutura intermaxilar (FARAM-SI). Também foi avaliada a trajetória dos canais ósseos formados a partir da FARAM. Nos pacientes dentados, foram localizados por meio da área dos dentes: incisivo central, incisivo lateral e caninos. Foi realizada a correlação entre a presença da FARAM e o gênero e a idade. Dos 150 exames, a FARAM estava presente em 21 exames (14%). Destes, dez pacientes eram edêntulos na região de interesse de estudo e não foi possível localizar a foramina em relação aos dentes. Nenhum exame apresentou a FARAM relacionada ao incisivo central, em sete estavam relacionadas ao incisivo lateral e em quatro estavam relacionadas ao canino. Nenhum exame apresentou a FARAM bilateralmente, sendo que treze foram localizadas no lado direito e oito do lado esquerdo. O diâmetro médio da FARAM foi de 1,57 ± 0,38 mm. As médias das distâncias de FARAM-RAV foi de 11,65 ± 3,34 mm, FARAM-FI foi de 8,86 ± 2,72 mm e FARAM-SI, foi de 6,37 ± 2,9 mm. A trajetória do canal ósseo mais comum foi ascendente/oblíqua em direção a região anterior do assoalho da cavidade nasal. A correlação entre a presença da FARAM e o gênero foi estaticamente significante para os homens (p=0,055) no teste do qui-quadrado. No entanto, não foi estatisticamente significante para a idade. / Through cone beam computed tomography (CBCT) is possible to evaluate the region of interest before surgical procedures in tridimensional view. Anatomical variations should be considered for performing surgeries, as the additional foraminas in anterior maxilla (AFAM). The main aim of the present study is evaluate AFAM in 150 CBCT exams, obtained through ICat Classic® device. In ICat Vision® software, the diameter, the distance from the AFAM to the incisive foramen (AFAM-IF), AFAM to the vestibular alveolar ridge (AFAM-VAR) and AFAM intermaxillary suture (AFAM-IS) were measured. It was also evaluated the trajectory of the bony canals related to AFAM. In dentate patients, AFAM was located through the teeth area: central incisor, lateral incisor and canines. The correlation between the presence of FARAM and gender and age was investigated. The AFAM was presented in 21 exams (14%). In the positive exams, 10 patients were edentulous in the region of study interest and it was not possible to locate the foramen in relation to the teeth. Any exam presented the AFAM related to the central incisor, in seven were related to the lateral incisor and in four were related to the canine. Any exam presented the AFAM bilaterally, of which thirteen were located on the right side and eight on the left side. The mean diameter of the AFAM was 1.57 ± 0.38 mm. The distance of the AFAM-VAR 11.65 ± 3.34 mm, AFAMIF was 8.86 ± 2.72 mm and AFAM-IS was 6.37 ± 2.9 mm. The most common bone canal trajectory was upward/ oblique to the anterior region of the floor of the nasal cavity. The correlation between the presence of AFAM and the gender was statically significant for males (p=0.055) in the chi-square test. However, it was not statistically significant for age.
1525

"Dipolos magnéticos da linha de transporte do feixe do microtron" / "Beam transport line dipole magnets of the Mirotron"

Mauricio de Lima Lopes 03 May 2002 (has links)
Neste trabalho apresentamos o projeto, construção e testes de eletroímãs dipolares usados na linha de transporte do feixe do Microtron do IFUSP. Inicialmente são feitos estudos da contribuição do campo de borda dos eletroímãs na curvatura total do feixe e posteriormente esses valores foram usados para a definição de parâmetros de projeto. Foram construídos e caracterizados dois dipolos (30 e 45o) e ainda um eletroímã seletor (+/- 90o) com simetria azimutal. Os resultados obtidos nos testes realizados com os dipolos mostraram um desempenho adequado à operação do acelerador. Também é descrito um método para a simulação da trajetória de elétrons na presença de um campo magnético. / In this work we present the design, construction and testing of dipole magnets used on the beam line of IFUSP-Microtron. Initially we studied the fringe field of the magnets on the total beam bending, these values had been used for the definition of design parameters. It has been constructed two dipoles (30 and 45o) as well as a switch magnet (+/- 90o) with azimuthal symmetry. The tests results of the dipoles had shown an adequate performance to the accelerators operation. A method for the simulation of the electron path in the presence of a magnetic field is also described.
1526

Avaliação da influência do volume do campo de visão na determinação da densidade mineral em tomografia computadorizada de feixe cônico e tomografia computadorizada multislice

Rodrigues, Andréia Fialho 29 October 2013 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2017-07-04T10:50:47Z No. of bitstreams: 1 andreiafialhorodrigues.pdf: 1214952 bytes, checksum: 9f8b3461dead1f5e477600658f658442 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-08T14:15:16Z (GMT) No. of bitstreams: 1 andreiafialhorodrigues.pdf: 1214952 bytes, checksum: 9f8b3461dead1f5e477600658f658442 (MD5) / Made available in DSpace on 2017-08-08T14:15:16Z (GMT). No. of bitstreams: 1 andreiafialhorodrigues.pdf: 1214952 bytes, checksum: 9f8b3461dead1f5e477600658f658442 (MD5) Previous issue date: 2013-10-29 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / As imagens de tomografia computadorizada de feixe cônico (TCFC) têm sido utilizadas para a avaliação da qualidade óssea, entretanto algumas variáveis inerentes ao exame parecem influenciar os valores de densidade obtidos, sendo que a influência do volume do campo de visão (FOV) ainda não foi completamente explicada. O objetivo deste estudo foi determinar os efeitos do volume do FOV no valor da densidade em TCFC e tomografia computadorizada multislice (TCMS). Um objeto teste composto por três cilindros de acrílico contendo água destilada, gesso e óleo de motor foi construído e inserido em um cilindro de acrílico completamente preenchido com água destilada. O objeto teste foi escaneado com uma TCFC e com uma TCMS, utilizando três tamanhos de FOV: 8x8cm, 16x8cm e 16x13cm. A densidade de cada material foi avaliada em 40 regiões de interesse posicionadas nos cortes axiais. Nos exames de TCFC, houve diferença significativa entre os valores de densidade dos diferentes FOVs para os três materiais. Já nos exames de TCMS houve diferença significativa somente para o óleo. Os valores de densidade mostraram significante correlação entre os exames de TCFC e TCMS para o gesso em todos os FOVs. A água não apresentou correlação significante entre os exames de TCFC e TCMS com os FOVs utilizados. O óleo não apresentou correlação no FOV 8 x 8mm e apresentou uma baixa correlação nos FOVs 16 x 8mm e 16 x 13mm. Os valores de densidade determinados em imagens de TCFC sofreram interferência significativa pela variação do tamanho do FOV. Os valores de densidade obtidos em exames de TCMS apresentaram diferença estatisticamente significante somente para o óleo. / Computed tomography cone beam (CBCT) scans have been used to evaluate the quality of bone. The values of density seem to be influenced by some CBCT inherent variables. However, some variables inherent to CBCT seem to influence the values of density and the influence of FOV volume has not been completely elucidated. The aim of this study was to determine the effects of FOV size on density values in large-volume CBCT and MSCT images. A phantom made up of 3 cylinders containing distilled water, plaster and motor oil was constructed and inserted into an acrylic cylinder filled with distilled water. The phantom was scanned with a CBCT and MSCT device using 3 FOV sizes. Density of each material was evaluated in 40 regions of interest. In CBCT exams there was significant difference between the density values of different FOVs for the 3 materials. In the MSCT there was significant difference only for the oil. A significant correlation between CBCT and MSCT exams for the plaster in all of the FOVs was obtained. The water did not show significant correlation between CBCT and MSCT exams with the FOVs under study. The oil was not correlated in 8 x 8mm FOV and a low correlation of the FOVs 16 x 8mm and 16 x 13mm. The density values determined in CBCT images showed significant interference by varying the size of the FOV. The density values obtained in MSCT examinations showed a statistically significant difference only for oil.
1527

Influência de diferentes protocolos de aquisição da imagem de tomografia computadorizada de feixe cônico para visualização das estruturas periodontais e mensuração do nível ósseo : estudo in-vitro / Influence of different cone-beam CT image acquisition protocols in the visualization of periodontal structures and in the bone heigth determination : in-vitro study

Macedo, Paulo de Tarso Silva de, 1989- 24 August 2018 (has links)
Orientador: Guilherme Monteiro Tosoni / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T18:16:43Z (GMT). No. of bitstreams: 1 Macedo_PaulodeTarsoSilvade_M.pdf: 1116393 bytes, checksum: 75612f26705c22bfdd039c815abb1367 (MD5) Previous issue date: 2014 / Resumo: O objetivo neste estudo foi avaliar a influência de diferentes protocolos de aquisição da imagem de Tomografia Computadorizada de Feixe Cônico (TCFC) na visualização das estruturas periodontais e na mensuração do nível ósseo alveolar. Inicialmente, foi realizada uma avaliação subjetiva sobre a qualidade de visualização das estruturas periodontais (cortical alveolar, espaço do ligamento periodontal e trabeculado ósseo) em imagens de TCFC, obtidas de crânios macerados com seis diferentes protocolos de aquisição, combinando-se tamanhos de voxel (0,20, 0,30 e 0,40mm) e graus de rotação (180 e 360º). As imagens foram avaliadas por três examinadores que atribuíram escores sobre a qualidade de visualização. Em seguida, realizou-se uma avaliação quantitativa, na qual o nível ósseo de 64 sítios apresentando perda óssea foi medido nas imagens de TCFC e nos crânios macerados. Após 30 dias, a amostra foi reexaminada. Para a avaliação qualitativa, o índice Kappa ponderado foi utilizado para avaliar as concordâncias intra- e interexaminador. As médias dos escores para cada uma das três estruturas periodontais, com cada protocolo de aquisição, foram comparadas utilizando-se a Análise de Variância (ANOVA) e Teste de Tukey. Para os dados quantitativos, o coeficiente de correlação intra-classe (ICC) foi aplicado para verificar as concordâncias intra- e interexaminador. A comparação entre as médias de erro dos diferentes protocolos também foi feita por meio da Análise de Variância (ANOVA) e teste de Tukey. O nível de significância adotado foi de 5%. De modo geral, o protocolo com menor tamanho de voxel e rotação completa do tubo apresentou escore significativamente melhor para a visualização das estruturas periodontais (p<0,0001). As concordâncias intra- e interexaminador também se mostraram fortes na avaliação quantitativa, com valores médios de ICC superiores a 0,90. As médias de erro dos protocolos que utilizaram voxel de 0,40 mm foram significativamente maiores que as dos outros protocolos (p<0,0001). Os protocolos que utilizam tamanhos de voxel de 0,20 e 0,30 mm, independente dos graus de rotação total (360º) ou parcial (180º), apresentaram a mesma acurácia na mensuração do nível ósseo alveolar. O grau de rotação não influenciou o resultado das mensurações do nível ósseo (p>0,05). Concluímos que, em relação à qualidade subjetiva da imagem, a combinação do menor tamanho de voxel (0,20 mm) com o grau de rotação total (360º) proporciona uma visualização significativamente melhor das estruturas periodontais. Do ponto de vista quantitativo, com relação à mensuração do nível ósseo alveolar, os tamanhos de voxel de 0,20 e 0,30 mm, independente dos graus de rotação total (360º) ou parcial (180º), apresentam a mesma acurácia / Abstract: The aim of this study was to assess the efficacy of cone-beam CT image acquisition protocols in the visualization of periodontal structures and periodontal bone height determination. First, subjective quality assessment of lamina dura delineation, trabecular bone and periodontal ligament space was performed using an ordinal scale ranging from 0 to 3 on CBCT scans obtained of dry skulls, with six different acquisition protocols, varying the voxel size (0.20, 0.30 and 0.40 mm) and degree of rotation (180 and 360º). In addition, a total of 64 sites, in the dry skulls, showing bone loss, were measured with a digital caliper (gold standard) and in the CBCT scans obtained with each protocol (quantitative analysis). The images were evaluated by 3 examiners. After 30 days, the total sample was re-evaluated. For subjective rating, weighted Kappa coefficients were calculated for intra- and inter-rater agreement. The mean scores of each structure in each of the protocols were compared by means of ANOVA one-way. Tukey¿s post hoc test was used to determine significant differences within protocols. For quantitative data, the intraclass correlation coefficients (ICC) was used to evaluate intra- and inter-examiner agreement; one-way ANOVA tested differences in mean errors for each acquisition protocol and Tukey¿s post hoc test was used to determine significant differences within protocols. The images acquired with lower voxel size and complete tube rotation (360º) were significantly superior in the visualization of lamina dura, trabecular bone and periodontal ligament space. ICC showed high intra- and inter-examiner agreement for all observations. There were significant differences (p<.0001) between the mean error (gold standard deviation) of periodontal bone level measurements of the 0.40 mm protocols, when compared with protocols using voxel sizes of 0.20 and 0.30 mm. The mean error of protocol that used 0.40 mm voxel size and half rotation (180º) was 0.57 mm, therefore, clinically significantly. Rotation arch did not influence the measurements of periodontal bone level. In conclusion, protocols that use 0.20 or 0.30 mm of voxel size, independently of the rotation arch, has the same accuracy in the measurement of periodontal bone height. The combination of smaller voxel (0.20 mm) with the complete tube rotation (360º) showed higher efficacy in the visibility of periodontal structures / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
1528

Influência do grau de rotação do aparelho e do crânio na espessura da cortical óssea em imagens de tomografia de feixe cônico : Evaluation of the influence of the unit and skull rotation on cortical bone thickness in cone beam computed tomography images / Evaluation of the influence of the unit and skull rotation on cortical bone thickness in cone beam computed tomography images

Marchini, Monikelly do Carmo Nascimento, 1986- 24 August 2018 (has links)
Orientador: Solange Maria de Almeida Bóscolo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T18:23:38Z (GMT). No. of bitstreams: 1 Marchini_MonikellydoCarmoNascimento_D.pdf: 1392987 bytes, checksum: e5d4a72a80998af2c16e333f3dee6408 (MD5) Previous issue date: 2014 / Resumo: A tomografia computadorizada de feixe cônico (TCFC) tem sido uma ferramenta de auxílio no diagnóstico, com várias aplicações clínicas. Devido ao aumento das diversas possibilidades de aquisição da imagem, há uma grande necessidade de um constante ajuste da imagem para cada proposta de diagnóstico. A avaliação da cortical óssea é importante para os casos de planejamento de implante imediato e para os casos em que há a necessidade de movimentação ortodôntica extensa. Entretanto, alguns fatores de qualidade de imagem devem ser considerados para uma acurada visualização da cortical óssea. Assim, com o presente estudo avaliou a influência do grau de rotação do aparelho, 3600 e 1800, bem como a influência de diferentes posições do crânio na avaliação da espessura da cortical óssea em imagens de TCFC. Para tanto, foram utilizados 11 crânios de humanos nos quais foram selecionados 59 dentes da maxila e mandíbula para avaliação de suas corticais ósseas. As imagens foram adquiridas no aparelho de TCFC Accuitomo 170, com voxel de 0,16mm, em quatro diferentes aspectos com relação à rotação do aparelho e posição do crânio respectivamente (protocolo 1: 3600/00; protocolo 2: 1800/00; protocolo 3: 1800/900; protocolo 4: 1800/1800). Para a avaliação das imagens, a cortical óssea foi classificada em três grupos de acordo com a condição ou espessura (cortical ausente, cortical fina e cortical espessa). No total 472 imagens bidimensionais (2D), referentes a cortes sagitais, foram avaliadas por três radiologistas previamente calibrados. Para concordância intra e interobservador foi utilizado o teste kappa e para avaliação das espessuras das corticais ósseas em relação ao real e entre os diferentes tipos de imagem foi utilizado o teste de Wilcoxon Signed Ranks. O teste de Kappa ponderado foi utilizado para comparar as diferentes condições da espessura óssea nos quatro protocolos de imagem. O nível de significância estabelecido foi de 95% (?=0,05). Os resultados obtidos mostraram que a concordância intraobservador variou de quase perfeita (k=0,87) a moderada (k=0,50) e a concordância interobservador variou de substancial (k=0,79) a moderada (k=0,56). De acordo com os resultados obtidos, observou-se que apenas para o protocolo 1 na região da cortical lingual, não houve diferença estatística entre as imagens e o padrão-ouro. Quando avaliando a cortical lingual, os maiores valores de concordância foram observados no protocolo 3, quando esta era ausente (k=0,80) e fina (k=0,47), já para cortical lingual espessa, o mais concordante foi o protocolo 2 (k=0,60). Avaliando-se somente a cortical vestibular, quando esta era ausente, o protocolo 3 exibiu o maior valor de concordância (k=0,61), enquanto que o protocolo 4 foi o mais concordante para cortical vestibular fina (k=0,38) e o protocolo 2 para a cortical vestibular espessa (k=0,40). Concluiu-se que o diagnóstico da espessura da cortical óssea não apresenta concordância perfeita com as imagens de TCFC, exceto para a região da cortical lingual no protocolo 1. Houve uma maior dificuldade de diagnóstico para a cortical vestibular em relação a lingual. Além disso, quando a espessura é mais fina, mais difícil é o diagnóstico / Abstract: The cone beam computed tomography (CBCT) has been a complement tool in diagnosis of many clinical applications. Due to the increase of the various possibilities of imaging, there is a great need for an image adjustment for each proposal to be diagnosed. The evaluation of cortical bone is important for implants pos-extraction placement and in cases requiring extensive orthodontic movement. However, some factors of image quality should be considered for accurate visualization of cortical bone. Thus, this study aimed to evaluate the influence of the arc rotation (3600 and 1800), and the influence of different positions of the skull to assess the thickness of buccal and lingual cortical bone in CBCT images. For this, 59 teeth of 11 human skulls in both arcs were selected. Images were made on Accuitomo 170 CBCT. The voxel size used was 0.16 mm. Four different aspects of image regarding the rotation of the device and position of the skull were made respectively (protocol 1: 3600/00; protocol 2: 1800/00; protocol 3: 1800/900; protocol 4: 1800/1800). For evaluation of the images, the cortical bone was classified into three groups according to the condition or the thickness (absent cortical, thin cortical, and thick cortical). A total of 472 two-dimensional images (2D) in sagittal sections were evaluated by three radiologists previously calibrated. For intra- and interobserver agreement kappa test was used. Wilcoxon Signed Ranks test was used to assess the cortical bone thickness compared to the gold standard and among different protocols. Ponderate Kappa test was used to compare conditions of cortical bone among protocols. The significance level was set at 95% (?=0.05). The results showed that the intraobserver agreement ranged from almost perfect (k=0.87) to moderate (k=0.50) and interobserver agreement ranged from substantial (k=0.79) to moderate (k=0.56). According to the results obtained, the protocol 1 showed that no statistical difference between the images and the gold standard was found only in lingual cortical bone region. When evaluating lingual cortical, higher reliability values was found with protocol 3 for absent (k=0.80) and thin (k=0.47), while for thick cortical in lingual side, the more consistent was the protocol 2 (k=0.60). Evaluating only buccal cortical side, the protocol 3 obtained the best agreement value for absent, (k=0.61), while the protocol 4 was better for thin cortical in buccal side (k=0.38), and protocol 2 for thick cortical in buccal side (k=0.40). It was concluded that the diagnosis of cortical bone thickness do not show agreement with CBCT images, except for lingual cortical bone in the protocol 1. There was more difficult diagnosis in buccal cortical compared to lingual cortical side. In addition, when the thickness is thinner more difficult the diagnosis is / Doutorado / Radiologia Odontologica / Doutora em Radiologia Odontológica
1529

Estudo da influência dos parâmetros de soldagem MIG e da morfologia do cordão no comportamento à fadiga de juntas soldadas de um eixo traseiro veicular. / Influence of MIG welding parameters and bead morphology on the fatigue behavior of the twist-beam rear axle welded joints.

Hamilton Soares Moreira 17 October 2008 (has links)
Atualmente a maioria dos veículos de passeio, pequenos e médios, são equipados com eixo traseiro do tipo interdependente. Seu baixo custo de fabricação e instalação fácil faz dele o preferido pela indústria automotiva. Normalmente, o eixo traseiro interdependente é um conjunto soldado e sua fabricação requer um controle do processo e qualidade das juntas soldadas de alto nível, devido a uma característica típica de projeto: eixos traseiros interdependentes possuem tensões críticas nos seus cordões de solda. Neste estudo, foi avaliado o quanto alterações nos parâmetros de soldagem afetam a geometria da solda e esta, por sua vez, compromete a vida à fadiga de um eixo interdependente. Através da variação dos parâmetros primários de soldagem (corrente, tensão e velocidade de soldagem), foi criado duas classes de eixos: classe A - 22V; 235A; 9mm/seg e classe B - 29V, 302A; 15mm/seg. Estes eixos foram submetidos a um ensaio de torção com carga em amplitude constante e seus desempenhos foram medidos através da curva de vida à fadiga. A variação dos parâmetros de soldagem afetou a geometria do cordão de solda, provocando nos eixos da classe B o surgimento de defeitos como baixa penetração da solda e mordedura. O resultado da análise metalográfica indica que estes defeitos influenciaram na resistência à fadiga dos eixos. A fractografia das fraturas confirmou que as falhas ocorreram por fadiga. / Nowadays most of the light, small and medium vehicles are equipped with a twist beam rear axle. Its low-cost production and easy assembly makes it the favorite axle type for the automotive industries and suspension developers. Usually the twist beam rear axle is a welded assembly and its production request a process control and high-level quality of the welded joint, due to a typical project characteristic: twist beam rear axle have critical tensions in their welds beads. It was evaluated in this study, how much the alterations in the welding parameters affects the weld bead geometry and this, for its time, affects the fatigue life of the twist beam rear axle. Through the variation of the welding primary parameters (welding current, arc voltage and welding speed), it was manufactured two classes of the axles: class \"A\" - 22V; 235A; 9mm/seg and class \"B\" - 29V, 302A; 15mm/seg. These axles were submitted the constant amplitude fatigue torsion testing and your performance were measured through the fatigue life curve. The variation of the welding parameters affected the weld bead geometry, inducing on the class \"B\" axle, the appearance of defects as low weld penetration and undercut. The metalography investigation indicates that these defects influenced in the fatigue life resistance. The fractures fractography confirmed that the flaws happened for fatigue.
1530

Intelligent STL file correction

Van Niekerk, G.J. 05 September 2012 (has links)
M.Sc. / Layered Manufacturing (LM), also known as "Rapid Prototyping", is that process in terms of which a computer-designed model is created layer by layer with the aid of specific LM hardware. Telemanufacturing constitutes an extension of this technology that allows remote submission of manufacturing jobs or assignments across a communication medium, typically the Internet, to be built at the manufacturing bureau concerned. The de facto standard of LM is the STL file. Simply put, this file consists of a number of triangles that are used to describe an object in its entirety. This file format has several advantages over other known formats and allows easy 2D rendering. Unfortunately, however, the limitations of the latter format outweigh its advantages. Since the entire model is described in terms of a collection of triangles, the original geometry of the model is lost. As a result, a certain level of degradation will occur, especially around curvatures in the model. Although an increase in the number of triangles around such areas will enhance precision, it will also result in a much larger STL file. Triangles that get lost somewhere inside the file could also give rise to holes, orphaned surfaces and zero-width walls in the projected object. It is vital, therefore, that the manufacturing bureau verify the correctness of the entire file before it is built in order to prevent machine time and materials from being wasted. Instead of transmitting the entire file again, the bureau could attempt automatically to correct and repair less critical errors, thereby saving valuable resources and time.

Page generated in 0.0275 seconds