• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 54
  • 4
  • 4
  • 4
  • 4
  • 4
  • 1
  • 1
  • Tagged with
  • 56
  • 56
  • 56
  • 54
  • 53
  • 37
  • 27
  • 25
  • 22
  • 16
  • 15
  • 15
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Desenvolvimento de métodos de preparo de amostras para posterior determinação de elementos traço em biodiesel por espectrometria de massa com setor eletromagnético com plasma indutivamente acoplado (SF-ICP-MS)

Barela, Pâmela Susin January 2017 (has links)
Neste trabalho, a decomposição por via úmida em sistema fechado assistida por radiação micro-ondas (MW-AD) e a decomposição por via úmida em sistema fechado assistida por radiação micro-ondas e ultravioleta (MW-UV) foram avaliadas para amostras comerciais de biodiesel para posterior determinação de Ba, Co, Cr, Cu, Mn, Mo, Ni, Pb, Sr, V e Zn por espectrometria de massa com setor eletromagnético com plasma indutivamente acoplado (SF-ICP-MS). A MW-AD empregando ácido diluído foi primeiramente avaliada sendo possível a decomposição de até 700 mg de biodiesel com HNO3 7 mol L-1 e 2 mL de H2O2 30% (m/m). As soluções finais apresentaram teor de carbono residual (RCC) de 8,7% e acidez residual (RA) de 4%. Posteriormente, com o objetivo de obter maior eficiência de decomposição, o método MW-UV foi avaliado para a decomposição de biodiesel. Com o emprego deste método até 950 mg de amostra foram decompostas com HNO3 7 mol L-1 e soluções finais com RCC de 17,4% e RA de 19,3% foram obtidas. As soluções finais, para ambos os métodos, foram adequadas para a determinação de elementos traço por SF-ICP-MS. Possíveis interferências na etapa de determinação dos analitos, causadas pela presença de carbono residual, foram estudadas através do emprego de padrão interno 115In e de ensaios de recuperação de analito para monitorar a formação de espécies poliatômicas no plasma. Os resultados obtidos mostraram a necessidade da utilização de padrão interno, sendo o instrumento operado no modo de baixa resolução para a determinação da maioria dos analitos, com exceção de 52Cr, para o qual o instrumento foi operado no modo de média resolução. A exatidão dos métodos propostos foi avaliada mediante a análise de material de referência certificado, obtendo-se resultados concordantes, com nível de confiança de 95% (teste t-student), com os valores certificados para a maioria dos elementos. Ensaios de adição de analito também foram feitos para a avaliação da exatidão e recuperações de 92 à 109% foram obtidas. Os limites de detecção (LD) obtidos para o método MW-UV foram inferiores aos obtidos para MW-AD, na faixa de 0,08 a 6,9 ng g-1 e 1,0 a 14 ng g-1, respectivamente. / In this work, the microwave-assisted digestion (MW-AD) and microwave-assisted ultraviolet digestion (MW-UV) were evaluated for commercial biodiesel samples for subsequent determination of Ba, Co, Cr, Cu, Mn, Mo, Ni, Pb, Sr, V and Zn by sector field inductively coupled plasma mass spectrometry (SF-ICP-MS). Using the MW-AD method with diluted acid up to 700 mg of biodiesel were digested with 7 mol L-1 HNO3 and 2 mL of 30% (w/w) H2O2. Final solutions presented residual carbon content (RCC) of 8.7% and residual acidity (RA) of 4%. In order to improve the digestion efficiency, the MW-UV method was evaluated for biodiesel digestion. Using MW-UV method up to 950 mg of sample were digested with 7 mol L-1 HNO3 and the final solutions with RCC of 17.4% and RA of 19.3% were obtained. The final solutions obtained for both methods were suitable for the determination of trace elements by SF-ICP-MS. Interferences in the determination step were studied using 115In as internal standard and analyte recovery to monitor the formation of polyatomic species in the plasma. The low resolution mode was used for the determination of almost of the analytes with the exception of 52Cr that was determine using medium resolution mode. Accuracy of the investigated methods were evaluated by analysis of certified reference material and the values obtained were in agreement with 95% confidence level (t-student test) with the certified values for all elements. Analyte recovery was also performed to evaluate the accuracy and recoveries of 92 to 109% were obtained. The limits of detection (LOD) obtained by the MW-UV method were lower than MW-AD method and are in the range of 0.08 to 6.9 ng g -1 and 1.0 to 14 ng g -1, respectively.
52

Desenvolvimento de métodos espectroanalíticos aplicados à documentoscopia, bens culturais e alimentos

BORBA, Flávia de S. L. 31 January 2012 (has links)
Submitted by Etelvina Domingos (etelvina.domingos@ufpe.br) on 2015-03-10T19:22:39Z No. of bitstreams: 2 tese_gravar_cd.pdf: 9826544 bytes, checksum: b8530b3e8f82a5777705f01c37bdaf7c (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-10T19:22:40Z (GMT). No. of bitstreams: 2 tese_gravar_cd.pdf: 9826544 bytes, checksum: b8530b3e8f82a5777705f01c37bdaf7c (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012 / CNPq / Esta tese é composta por três trabalhos. O primeiro trabalho trata do desenvolvimento de um método analítico não destrutivo para discriminar tintas de canetas azuis do tipo gel (3 marcas), esferográfica (5 marcas) e rollerball (2 marcas). Foram adquiridos espectros de infravermelho médio por reflectância total atenuada de círculos preenchidos com tinta em três tipos de papel A4, sendo duas marcas de papel branco (papel 1 e papel 2) e uma de papel reciclado (papel 3). O algoritmo Kennard-Stone foi utilizado para selecionar os espectros do papel 1 para compor os conjuntos de treinamento, validação e teste. Foram construídos dois modelos com a análise discriminante linear sendo um com as classes compostas pelo tipo e o outro pelas marcas das tintas. Um novo conjunto de teste composto pelos espectros obtidos no papel 2 e 3 foi utilizado para avaliar a influência do papel nas predições dos modelos. Foi obtido 100% de classificação correta em todos os conjuntos de teste, exceto na classificação por marca do papel 3, em que foi obtida 91,3% de classificação correta. Na segunda parte desta tese, a espectroscopia de emissão em plasma induzido por laser (LIBS) foi empregada para analisar sete tijolos antigos e dois fragmentos de pinturas rupestres pertencentes a dois sítios arqueológicos brasileiros, sendo um no estado do Piauí (Toca da Extrema II) e outro no estado do Rio Grande do Norte (Xique-xique). Um instrumento LIBS construído no laboratório (laser Nd:YAG, 1064 nm, 5,2 ns), contendo um policromador echelle, foi empregado para a aquisição dos espectros. Devido à complexidade dos espectros, a análise de componentes principais foi empregada para explorar o conjunto de dados. Os tijolos foram discriminados pelos seus teores de Ti, Zr, Sr e Fe. Estudos preliminares envolvendo uma pintura realizada sobre uma tela de madeira contendo diferentes camadas de material foram realizados para determinar a melhor energia do pulso de laser. Para cada fragmento de pintura, foram realizados 8 pulsos sucessivos em 16 locações diferentes, sendo 8 locações sobre a pintura e 8 sobre o substrato. Neste trabalho foi demonstrado que a utilização de técnicas multivariadas é indispensável devido à grande complexidade dos espectros obtidos durante estudo de profundidade de amostras arqueológicas. Finalmente, a terceira parte desta tese foi dedicada a avaliação do efeito de matriz na determinação da concentração de 20 elementos em suplemento alimentar, por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). Foram adquiridas em estabelecimentos comerciais, diferentes marcas de um suplemento alimentar inicialmente designado de “Ração Humana”, cuja composição é variada, mas pode conter cereais, farelos, fibras, farinhas, linhaça, gergelim, extrato de soja, levedo de cerveja, cacau em pó, gelatina em pó e guaraná em pó. Três procedimentos de decomposição foram avaliados: (1) decomposição assistida por microondas, (2) decomposição por combustão na mufla com aditivos e (3) decomposição por combustão na mufla sem aditivos. Os melhores resultados foram obtidos com a digestão por combustão na mufla sem aditivos. Com exceção do Mo, o nível de todos os elementos determinados de forma preliminar estão em concordância com os níveis reportados em produtos destinados à nutrição previamente descritos na literatura.
53

[en] DEVELOPMENT OF CAPILLARY ELECTROPHORESIS BASED METHODS WITH DIFFERENT DETECTION APPROACHES FOR DETERMINATION OF ORGANOTINS, STROBILURINS AND AMINOGLYCOSIDES / [pt] DESENVOLVIMENTO DE MÉTODOS BASEADOS NA ELETROFORESE CAPILAR COM DIFERENTES ABORDAGENS DE DETECÇÃO PARA DETERMINAÇÃO DE ORGANOESTANHOS, ESTROBILURINAS E AMINOGLICOSÍDEOS

CABRINI FERRAZ DE SOUZA 02 July 2014 (has links)
[pt] Neste trabalho, métodos baseados em diferentes abordagens em eletroforese capilar (CE) foram propostos. No caso da determinação de compostos organoestanhos ou OTs (difenilestanho e monofenilestanho) em fluidos biológicos, foi usada abordagem de eletroforese capilar por zona (CZE) hifenada com a espectrometria de massas (do tipo quadrupolo) com fonte de plasma indutivamente acoplado (CE-ICP-MS). As condições de análise foram estudadas no modo univariado visando otimizar a composição da solução eletrolítica (tampão acetato 5,0 mmol L(-1), pH 2,8) e obter os parâmetros instrumentais (45 graus Celsius, mais 30 kV e 30 s de tempo de introdução hidrodinâmica de amostra). A solução de complementação foi uma solução aquosa 5,0 mmol L(-1) de NH4NO3 contendo 10 por cento metanol em volume e 1,0 Mg L(-1) de Cspositivo, com pH ajustado para 2,8 com tampão acetato. A vazão dessa solução foi mantida em 40 ML min(-1). Os OTs foram diluídos em solução de metanol:tampão acetato de sódio 50:50 por cento v/v ou apenas em tampão acetato de sódio pH 2,8. As condições de detecção do ICP-MS foram ajustadas em 1200 W, 15 L min(-1) de vazão de argônio para formação do plasma, 1 L min(-1) de vazão de argônio auxiliar. A vazão de argônio do nebulizador foi ajustada diariamente. Os isótopos de estanho 120Sn e 118Sn foram monitorados, assim como o 133Cspositivo para controlar a eficiência e estabilidade do processo de nebulização. A resposta linear do método ficou entre 0,050 a 2,0 mg L(-1) de Sn (0,42 a 17 Mmol L-(1)). Os limites de detecção (LOD) e de quantificação (LOQ) em termos de Sn foram de 15 Mg L(-1) (0,13 Mmol L(-1)) e 50 Mg L-1 (0,42 Mmol L(-1)), calculados utilizando a menor concentração dos picos dos analitos que podem ser diferenciados do sinal de fundo. A repetibilidade para o tempo de migração e área dos picos ficou próximo a 5 por cento. O método foi aplicado na análise de urina, sangue total e plasma fortificados com os OTs. Recuperações entre 75 e 95 por cento foram obtidas. No caso da determinação de sete pesticidas da classe das estrobilurinas (azoxistrobina, 9 dimoxistrobina, fluoxastrobina, picoxistrobina, piraclostrobina, trifloxistrobina e kresoxim-metil) em sopas infantis, foi usada a cromatografia eletrocinética capilar micelar (MEKC) com detecção fotométrica (no UV) com capilar de caminho óptico estendido. Um estudo multivariado, usando um planejamento 33 Box Behnken, indicou que a melhor separação para os pesticidas foi com solução aquosa de eletrólito composto por tampão tetraborato de sódio (5,1 mmol L(-1), pH 9,0) contendo 51 mmol L(-1) de dodecil sulfato de sódio (SDS) e 24 por cento acetonitrila (ACN) em volume. As condições instrumentais foram 25 C e mais 30 kV de diferença de potencial aplicada, 45 s de tempo de introdução hidrodinâmica de amostra e detecção em 210 nm. Para aumentar o poder de detecção, foi usada a concentração dos analitos no capilar. Para tal, as soluções de padrões e amostras foram dissolvidas em solução tampão tetraborato de sódio 45 mmol L(-1): acetonitrila 80:20 por cento v/v. As curvas analíticas apresentaram comportamento linear e os valores de LOD ficaram entre 7,0 Mg L(-1) ou 18 nmol L(-1) (piraclostrobina) a 15 Mg L-1 ou 33 nmol L(-1) (fluoxastrobina). Os valores de LOQ ficaram entre 21 Mg L(-1) ou 54 nmol L(-1) (piraclostrobina) a 45 Mg L(-1) ou 98 nmol L(-1) (fluoxastrobina). A repetibilidade ficou entre 1,7 a 7,9 por cento para a área de pico e entre 0,25 a 0,71 por cento para o tempo de migração. A precisão intermediária, avaliada com análises realizadas em diferentes dias, apresentou valores entre 1,3 a 5,3 por cento para a área de pico e entre 0,06 a 0,90 por cento para o tempo de migração. O método foi aplicado na análise de sopas prontas infantis fortificadas com as estrobilurinas. Os pesticidas foram extraídos aplicando o método QuEChERS com ajuste de pH com tampão acetato e limpeza com extração em fase sólida dispersiva. Os resultados das análises obtidos com um método cromatográfico adaptado da literatura foram estatisticamente iguais aos alcançados com o método proposto. A CZE foi o modo de separação escolhido para mostrar o potencial da determinação indireta de aminoglicosídeos com medição de fluorescência de pontos quânticos (excitação com laser de diodo em 410 nm) amplificada na presença dos analitos. A fotoluminescência dos pontos quânticos (nanopartículas de CdTe modificados com ácido tioglicólico monodispersas em solução) foi mais intensa em solução tampão (pH 8,0) contendo entre 5 e 10 mmol L(-1) de tetraborato de sódio. A interação no capilar entre aminoglicosídeos (neomicina e canamicina) e os pontos quânticos provocou aumento de fotoluminescência dependente do pH do meio (indício de interação de natureza 10 eletrostática). Alguns parâmetros de mérito foram avaliados com uma faixa linear curta (0,1 a 1,0 mol L(-1) para canamicina e 0,03 a 0,5 mol L(-1) para neomicina). Os valores mínimos detectados de 0,1 Mmol L(-1) ou 58 Mg L(-1) (canamicina) e 0,03 Mmol L(-1) ou 27 Mg L(-1) (neomicina) mostram que essa é uma abordagem interessante para a determinação sensível de aminoglicosídeos. / [en] In this work, analytical methods based on different approaches using capillary electrophoresis (CE) have been proposed. For the determination of organotins or OTs (diphenyltin and monophenyltin) in biological fluids, the separation using capillary zone electrophoresis (CZE) was applied using tandem with inductively coupled plasma mass spectrometry (CE-ICP-MS). The conditions for the analysis were optimized in an unvaried way aiming to find the conditions for the electrolyte solution (acetate buffer, 5.0 mmol L (-1), pH 2.8) and the employed instrumental parameters (45C, 30 kV and 30 s of the time for hydrodynamic introduction of the sample). A complementary solution was composed by NH4NO3 5.0 mmol L(-1), 10 por cento v/v of methanol and 1.0 g L(-1) of Cspositive in acetate buffer with pH adjusted to 2.8. The flow of this solution was set to 40 ML min(-1). The OTs were diluted either in a methanol: acetate buffer 50:50 por cento v/v solution or only in sodium acetate buffer pH 2.8. The conditions for detection by ICP-MS were set to 1200 W, 15 L min(-1) for the Ar plasma flow and 1,0 L min(-1) for the auxiliary Ar. The nebulizer Ar flow was adjusted daily. The monitored tin isotopes were 120Sn 118Sn. The isotope 133Cs was also monitored in order to control the efficiency and stability of the nebulization. The method presented a linear response between 0.05 and 2.0 mg L(-1) (0.42 a 17 Mmol L(-1)) for Sn. The value for the limits of detection (LOD) and for the limits of quantification (LOQ) for Sn were 15 Mg L(-1) (0.13 Mmol L-1) e 50 Mg L(-1) (0.42 Mmol L(-1)), calculated based on the lowest concentration of the analyte peaks that can be differentiated from the background signal. The repeatability for migration time and peak area was approximately 5 per cent. The method was applied in the analysis of organotin fortified blood and urine samples with recoveries between 75 and 95 per cent. In the case of the determination of seven strobilurin class pesticides (azoxystrobin, dimoxystrobin, fluoxastrobin, picoxystrobin, pyraclostrobin, trifloxystrobin and kresoxim-methyl) in baby food (vegetable and fruit soups), 12 the micellar electrokinetic capillary chromatography (MEKC) was used using photometric detection (UV) in a capillary with extended optical path. A multivariate study, with 33 Box Behnken design, indicated the best composition for the electrolytic solution to separate the seven pesticides: a sodium tetraborate buffer (5.1 mmol L(-1), pH 9.0) solution containing 51 mmol L(-1) sodium dodecyl sulfate and acetonitrile (24 por cento in volume). The instrumental conditions were 25C, 30 kV of applied voltage, 45 s for hydrodynamic introduction of the sample and detection at 210 nm. To increase the detection power, the concentration of the analytes into the capillary was used by using the Normal Stacking Mode. For this purpose, the solutions of standards and samples were prepared in 45 mmol L(-1) sodium tetraborate buffer solution: acetonitrile 80:20 por cento v/v. The analytical curves presented a linear behavior and the LOD values were between 7.0 Mg L (-1) or 18 nmol L(-1) (pyraclostrobin) to 15 Mg L(-1) or 33 nmol L(-1) (fluoxastrobin). The LOQ values were between 21 Mg L(-1) or 54 nmol L(-1) (pyraclostrobin) a 45 Mg L(-1) ou 98 nmol L(-1) (fluoxastrobin). The repeatability was between 1.7 to 7.9 por cento for the peak area and between 0.25 to 0.71 por cento for the migration time. The intermediate precision, evaluated by the analysis performed in different days were between 1.3 to 5.3 por cento for the peak area and between 0.06 and 0.90 per cent for the migration time. The method was applied in the analysis of baby food spiked with strobilurin. Pesticides were extracted using the QuEChERS method with pH adjustment with acetate buffer and clean-up using the dispersive solid phase extraction. The analysis results were statistically identical to those obtained with a chromatographic method adapted from the literature. The CZE separation mode was chosen to evaluate the potential of the indirect determination of aminoglycosides through the amplified photoluminescence from quantum dots (excitation laser diode 410 nm) in the presence of the analytes. The photoluminescence from quantum dots (monodispersed CdTe nanoparticles modified with thioglycolic acid) was more intense in buffer solution (pH 8.0) containing between 5 and 10 mmol L(-1) sodium tetraborate. The interaction between aminoglycosides (kanamycin and neomycin) and quantum dots inside the capillary caused the increasing of fluorescence in a pH-dependent way (indicating the electrostatic nature for the interaction). A few figures of merit were evaluated with a short linear range (0.1) to 1.0 Mmol L(-1) for kanamycin and 0.03 to 0.5 Mmol L(-1) for neomycin). The 13 minimum values detected were 0.1 nmol L(-1) or 58 Mg L(-1) (kanamycin) and 0.03 nmol L(-1) or 27 Mg L(-1) (neomycin) showing that the proposed approach can be used to detect aminoglycosides in a relatively sensitive way.
54

Desenvolvimento de método para a determinação de irídio, paládio, platina e ródio por ICP OES em sílica mesoporosa para uso catalítico / Development of method for the determination of iridium, palladium, platinum and rhodium in mesoporosa silica for catalyst use by ICP OES

Sousa, Valeska Meirelles 10 July 2012 (has links)
O objetivo deste estudo foi avaliar parâmetros tais como, moagem, tamanho de partículas, homogeneidade, segregação, dissolução de amostras e amostragem de suspensão, visando o desenvolvimento de método para a determinação de Ir, Pd, Pt e Rh por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) em sílica mesoporosa para uso catalítico. Após a moagem em moinho eletrônico de almofariz e pistilo, a análise do tamanho e distribuição das partículas revelou que 89% das partículas apresentam tamanhos <100 &#181;m e 23% com tamanho <5 &#181;m. Na avaliação de segregação dos analitos na amostra, os resultados obtidos para amostra com moagem grosseira, indicaram que os elementos estão distribuídos de maneira heterogênea entre as frações. Entretanto, a moagem fina aumentou a homogeneidade e esta pode ser uma etapa importante e necessária no sentido de evitar segregação da amostra. A análise por difração e de Raios-X mostrou que não ocorreram reações mecanoquímicas durante a moagem e por fluorescência de Raios-X forneceu resultados discrepantes entre os laboratórios, o pode estar relacionado com a heterogeneidade que induziu erros de amostragem. A avaliação de desempenho do ICP OES foi feita a partir do estabelecimento de parâmetros de mérito como seletividade, repetibilidade, estabilidade, robutez e limite de detecção. Na otimização foram considerados os parâmetros potência, vazão de nebulização e vazão de gás auxiliar. Foi feito um estudo em solução aquosa e em meio da amostra para escolha das linhas de emissão dos elementos Ir, Pd, Pt, Rh e dos candidatos a padrões internos. Apesar dos bons resultados encontrados em solução aquosa, o aumento do sinal de fundo em meio da amostra restringiu a escolha dos comprimentos de onda. Para o estudo da dissolução das amostras foram avaliados quatro procedimentos em forno de micro-ondas com frasco fechado. Os melhores resultados foram obtidos com 150 mg de amostra, 6 mL de água régia e 210 ºC de aquecimento durante 60 min. As determinações por ICP OES usando padrões internos Ru para Pd, Yb para Pt e Dy para Rh foram aquelas que forneceram os resultados mais coerentes com aqueles obtidos por fluorescência de Raios-X. Nos estudos visando à introdução de amostra na forma de suspensão foram avaliados: a massa de amostra para o preparo da suspensão, o efeito da concentração de ácido nítrico e o uso de padrão interno na tentativa de corrigir erros de matriz. 60 mg de amostra com um volume final de 20 mL de ácido nítrico 0,5% (v v-1) foram os escolhidos. Entretanto, a determinação dos elementos via suspensão mostrou resultados muito inferiores aos valores de concentrações esperados. Irídio foi investigado somente para otimização de ICP OES porque a sílica mesoporosa para uso de catalisador automotivo tem não esse elemento em sua composição. / The aim of this study was to evaluate parameters such as grinding, particle size, homogeneity, segregation, sample dissolution and slurry sampling for method development for the determination of Ir, Pd, Pt and Rh in silica mesoporosa for catalyst using inductively coupled plasma optical emission spectrometry (ICP OES). After the grind in an electronic grider with mill and pistil, the analysis of the particle size distribution showed 89% of particles with sizes <100 &#181;m and 23% of particles with sizes <5&#181;m. The separation in different particle size fractions showed that the sample with coarse grind (as sent to the lab) is not homogenous for the elements in comparison with that submitted to grind. X-Ray Diffraction and X-Ray Fluorescence analysis did not showed chemical reactions during the grinding, however a discrepancy between results of different laboratories. The performance of ICP OES was made by using figures of merit such as selectivity, repeatability, stability, robustness and limit of detection. In the optimization of ICP OES power supply, nebulizer flow rate and auxiliary gas flow rate were considered. Studies were conducted in aqueous and in the sample solution to choose emission wavelengths for Ir, Pd, Pt, Rh and internal standard candidates. Despite the good results obtained in aqueous solution, increasing the background signal in sample media restricted the choice of the emission wavelengths. For sample dissolution four procedures using microwave oven with closed-vessel were evaluated. The best results were obtained with 150 mg of the sample, 6 mL of aqua-regia and 210 ºC of heating, during 60 min. Determinations by ICP OES using internal standards Ru for Pd, Yb for Pt, and Dy for Rh were those who provided more consistent results in comparison with those obtained by x-ray fluorescence. For slurry sampling introduction sush parameters were evaluated: the mass of sample to prepare the slurry, the effect of the nitric acid concentration and the use of internal standard to correct matrix effects. 60 mg of the sample with a final volume of 20 mL of nitric acid 0.5% (v v-1) were chosen. However, the determination of Pd, Pt and Rh via suspension showed concentrations below to those expected, as determined by ICP OES in solution. Iridium was investigated only for ICP OES optimization because the silica mesoporosa for automobile catalyst use have not this element in its composition.
55

Desenvolvimento de método para a determinação de irídio, paládio, platina e ródio por ICP OES em sílica mesoporosa para uso catalítico / Development of method for the determination of iridium, palladium, platinum and rhodium in mesoporosa silica for catalyst use by ICP OES

Valeska Meirelles Sousa 10 July 2012 (has links)
O objetivo deste estudo foi avaliar parâmetros tais como, moagem, tamanho de partículas, homogeneidade, segregação, dissolução de amostras e amostragem de suspensão, visando o desenvolvimento de método para a determinação de Ir, Pd, Pt e Rh por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) em sílica mesoporosa para uso catalítico. Após a moagem em moinho eletrônico de almofariz e pistilo, a análise do tamanho e distribuição das partículas revelou que 89% das partículas apresentam tamanhos <100 &#181;m e 23% com tamanho <5 &#181;m. Na avaliação de segregação dos analitos na amostra, os resultados obtidos para amostra com moagem grosseira, indicaram que os elementos estão distribuídos de maneira heterogênea entre as frações. Entretanto, a moagem fina aumentou a homogeneidade e esta pode ser uma etapa importante e necessária no sentido de evitar segregação da amostra. A análise por difração e de Raios-X mostrou que não ocorreram reações mecanoquímicas durante a moagem e por fluorescência de Raios-X forneceu resultados discrepantes entre os laboratórios, o pode estar relacionado com a heterogeneidade que induziu erros de amostragem. A avaliação de desempenho do ICP OES foi feita a partir do estabelecimento de parâmetros de mérito como seletividade, repetibilidade, estabilidade, robutez e limite de detecção. Na otimização foram considerados os parâmetros potência, vazão de nebulização e vazão de gás auxiliar. Foi feito um estudo em solução aquosa e em meio da amostra para escolha das linhas de emissão dos elementos Ir, Pd, Pt, Rh e dos candidatos a padrões internos. Apesar dos bons resultados encontrados em solução aquosa, o aumento do sinal de fundo em meio da amostra restringiu a escolha dos comprimentos de onda. Para o estudo da dissolução das amostras foram avaliados quatro procedimentos em forno de micro-ondas com frasco fechado. Os melhores resultados foram obtidos com 150 mg de amostra, 6 mL de água régia e 210 ºC de aquecimento durante 60 min. As determinações por ICP OES usando padrões internos Ru para Pd, Yb para Pt e Dy para Rh foram aquelas que forneceram os resultados mais coerentes com aqueles obtidos por fluorescência de Raios-X. Nos estudos visando à introdução de amostra na forma de suspensão foram avaliados: a massa de amostra para o preparo da suspensão, o efeito da concentração de ácido nítrico e o uso de padrão interno na tentativa de corrigir erros de matriz. 60 mg de amostra com um volume final de 20 mL de ácido nítrico 0,5% (v v-1) foram os escolhidos. Entretanto, a determinação dos elementos via suspensão mostrou resultados muito inferiores aos valores de concentrações esperados. Irídio foi investigado somente para otimização de ICP OES porque a sílica mesoporosa para uso de catalisador automotivo tem não esse elemento em sua composição. / The aim of this study was to evaluate parameters such as grinding, particle size, homogeneity, segregation, sample dissolution and slurry sampling for method development for the determination of Ir, Pd, Pt and Rh in silica mesoporosa for catalyst using inductively coupled plasma optical emission spectrometry (ICP OES). After the grind in an electronic grider with mill and pistil, the analysis of the particle size distribution showed 89% of particles with sizes <100 &#181;m and 23% of particles with sizes <5&#181;m. The separation in different particle size fractions showed that the sample with coarse grind (as sent to the lab) is not homogenous for the elements in comparison with that submitted to grind. X-Ray Diffraction and X-Ray Fluorescence analysis did not showed chemical reactions during the grinding, however a discrepancy between results of different laboratories. The performance of ICP OES was made by using figures of merit such as selectivity, repeatability, stability, robustness and limit of detection. In the optimization of ICP OES power supply, nebulizer flow rate and auxiliary gas flow rate were considered. Studies were conducted in aqueous and in the sample solution to choose emission wavelengths for Ir, Pd, Pt, Rh and internal standard candidates. Despite the good results obtained in aqueous solution, increasing the background signal in sample media restricted the choice of the emission wavelengths. For sample dissolution four procedures using microwave oven with closed-vessel were evaluated. The best results were obtained with 150 mg of the sample, 6 mL of aqua-regia and 210 ºC of heating, during 60 min. Determinations by ICP OES using internal standards Ru for Pd, Yb for Pt, and Dy for Rh were those who provided more consistent results in comparison with those obtained by x-ray fluorescence. For slurry sampling introduction sush parameters were evaluated: the mass of sample to prepare the slurry, the effect of the nitric acid concentration and the use of internal standard to correct matrix effects. 60 mg of the sample with a final volume of 20 mL of nitric acid 0.5% (v v-1) were chosen. However, the determination of Pd, Pt and Rh via suspension showed concentrations below to those expected, as determined by ICP OES in solution. Iridium was investigated only for ICP OES optimization because the silica mesoporosa for automobile catalyst use have not this element in its composition.
56

Desenvolvimento e validação de métodos analíticos para a determinação de contaminantes em polietileno tereftalato e polietileno de alta densidade pós-consumo / Development and validation of analytical methods for the determination of contaminants in polyethylene terephthalate and high-density polyethylene post consumer

Dutra, Camila Braga 16 August 2018 (has links)
Orientadores: Felix Guillermo Reyes Reyes, Maria Teresa de Alvarenga Freire / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-16T23:01:27Z (GMT). No. of bitstreams: 1 Dutra_CamilaBraga_D.pdf: 1974104 bytes, checksum: 7a0aae96f3654e27fb7d553ee756e522 (MD5) Previous issue date: 2010 / Doutorado / Doutor em Ciência de Alimentos

Page generated in 0.073 seconds