• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Reprodutibilidade da cinemática da escápula, úmero e tronco em adultos saudáveis, comparando as avaliações entre os avaliadores experiente e inexperiente / Reliability of scapula, humerus and trunk kinematics in healthy adults, comparing the evaluations between experienced and inexperienced evaluators

Gonçalves, Diogo Henrique Magalhães 07 December 2016 (has links)
Submitted by Nadir Basilio (nadirsb@uninove.br) on 2018-07-23T18:20:19Z No. of bitstreams: 1 Diogo Henrique Magalhães Gonçalves.pdf: 1521507 bytes, checksum: 0d42f8a3b94345ef905deb7a85a90628 (MD5) / Made available in DSpace on 2018-07-23T18:20:19Z (GMT). No. of bitstreams: 1 Diogo Henrique Magalhães Gonçalves.pdf: 1521507 bytes, checksum: 0d42f8a3b94345ef905deb7a85a90628 (MD5) Previous issue date: 2016-12-07 / The reproducibility of scapular kinematics has already been tested intra- and inter-sessions and intra- and inter-days, however, these evaluations were only performed by experienced evaluators and the majority of studies included only one evaluator. Thus, the comparison between evaluators with different levels of experience has not yet been explored, leaving doubts as to the accuracy of the evaluation results when performed by different evaluators. The objective of the present study was to evaluate the reproducibility inter and intra-rater, experienced and inexperienced, during flexion and abduction movements of the arm for the scapula, humerus, and trunk segments. Kinematic data were captured during flexion and abduction movements of the arm using a system of 8 cameras and a sampling frequency of 120 Hz. In total, twenty healthy volunteers were evaluated (10 men and 10 women), with an average age of 25.1 (1.1) years, who underwent 6 sessions of movement analysis. Each evaluator carried out three sessions, two sessions on the first day, with a three-hour interval between them, and the third session on the second day, twenty-four hours after the first day. For each session, 5 repetitions of each movement, unilateral abduction and flexion of the arm, were performed. Statistical analysis was performed by an independent evaluator and the Shapiro-Wilk test was used for data distribution. The reproducibility of the range of motion and angular values at angles of 30º, 60º, 90º, and 120º was verified through the intraclass correlation coefficient (ICC) and standard measurement error (SEM). The values obtained for the angles 30°, 60°, 90°, and 120° intra-day ranged from 0.67-0.98 and (0.58° to 5.64°) for the inexperienced evaluator and from 0.67° to 0.98° and (0.64° to 6.17°) for the experienced evaluator in the flexion movement. During the abduction movement the values obtained at angles of 30°, 60°, 90°, and 120° intra-day ranged from 0.75° to 0.96° and (0.51° to 4.93°) for the inexperienced evaluator and from 0.62° to 0.97° and (0.66° to 6.58°) for the experienced evaluator. The model presented good to excellent intra-day reproducibility for both evaluators in the flexion and abduction movements of the arm. Inter-day values in flexion varied from 0.41° to 0.88° and (0.64° to 6.17°) for the inexperienced evaluator and 0.72° to 0.95° and (0.67° to 4.31°) for the experienced evaluator. In the inter-day abduction movement, values ranged from 0.33° to 0.91° and (0.74° to 6.60°) for the inexperienced evaluator and 0.72° to 0.98° and (0.73° to 5.01°) for the experienced evaluator. The reproducibility of the inexperienced evaluator presented from weak to excellent in the arm flexion movement and poor to excellent in abduction of the arm. The reproducibility for the experienced evaluator was good to excellent for flexion and abduction of the arm between the scapula, humerus, and trunk segments in healthy adults. The results showed that there is no difference between evaluators in the intra-day evaluations; however, on an inter-day basis the experienced evaluator obtained better reproducibility results, demonstrating that a difference in levels of experience between evaluators is of fundamental importance to obtain reproducible results on different days. However, we emphasize the importance of performing further studies, with different movements and patients, performed by two or more evaluators. / A reprodutibilidade da cinemática escapular já foi testada intra e inter-sessões e intra e inter-dias, porém essas avaliações foram realizadas apenas por avaliadores experientes e a maioria dos estudos com apenas um avaliador. A comparação entre avaliadores com diferentes níveis de experiência ainda não foi explorada, deixando dúvidas quanto a precisão dos resultados da avaliação se realizadas por diferentes avaliadores. O objetivo do presente estudo foi avaliar a reprodutibilidade inter e intra-avaliadores, com diferentes níveis de experiência, nos movimentos de flexão e abdução do braço para os segmentos da escápula, úmero e tronco. As capturas dos dados de cinemática foram realizadas utilizando um sistema de 8 câmeras e frequência de amostragem de 120Hz durante os movimentos de flexão e abdução do braço. Foram avaliados 20 voluntários saudáveis (10 homens e 10 mulheres) com idade média de 25.1 (±1.1) anos, que foram submetidos à 6 sessões de análise do movimento. Cada avaliador realizou três sessões, duas sessões realizadas no primeiro dia com intervalo de três horas entre elas e a terceira sessão foi realizada no segundo dia, 48 horas após o primeiro dia. Para cada sessão foram realizadas 5 repetições de cada movimento, abdução e flexão unilateral do braço. A análise estatística foi realizada por um avaliador independente, para distribuição dos dados, foi utilizado o teste de Shapiro-Wilk, A reprodutibilidade da amplitude de movimento e dos valores angulares nos ângulos de 30º, 60º, 90º e 120º do braço foi verificada pelo coeficiente de correlação intraclasse (ICC) assim como o erro de medida padrão (SEM). Os valores obtidos nos ângulos de 30°, 60°, 90° e 120° intra-dia variaram de 0,67-0,98 e (0,58° à 5,64°) para o avaliador inexperiente e variaram de 0,67-0,98 e (0,64° à 6,17°) para o avaliador experiente, no movimento de flexão. Durante o movimento de abdução os valores obtidos nos ângulos de 30°, 60°, 90° e 120° intra-dia variaram de 0,75-0,96 e (0,51° à 4,93°) para o avaliador inexperiente e variaram de 0,62-0,97 e (0,66° à 6,58°) para o avaliador experiente. O modelo apresentou de boa a excelente reprodutibilidade, intra-dia para ambos os avaliadores nos movimentos de flexão e abdução do braço. Os valores obtidos inter-dias na flexão variaram de 0,41 a 0,88 e (0,64° a 6,17) para o avaliador inexperiente e de 0,72 a 0,95 e (0,67° a 4,31°) para o avaliador experiente. No movimento de abdução inter-dias os valores variaram de 0,33 a 0,91 e (0,74° a 6,60°) para o avaliador inexperiente e de 0,72 a 0,98 e (0,73° a 5,01°) para o avaliador experiente. Apresentando a reprodutibilidade do avaliador inexperiente de fraca a excelente no movimento de flexão do braço e pobre a excelente na abdução do braço. A reprodutibilidade para o avaliador experiente foi de boa a excelente para a flexão e abdução do braço entre os segmentos da escápula, úmero e tronco em adultos saudáveis. Mostrando que não há diferença entre avaliadores nas avaliações intra-dia, porém inter-dias o avaliador experiente obteve melhores resultados de reprodutibilidade, mostrando que a diferença de níveis de experiência entre os avaliadores é de fundamental importância para se ter resultados reprodutíveis em diferentes dias. Entretanto devemos ressaltar a importância de mais estudos serem realizados, com diferentes movimentos e pacientes, realizados por dois ou mais avaliadores.

Page generated in 0.4376 seconds