Spelling suggestions: "subject:"filtração.""
71 |
Comparação da infiltração apical entre canais obturados com guta-percha/AH Plus e o sistema Resilon/Epiphany quando submetidos a duas técnicas de obturação / Comparison of apical leakage between canals filled with gutta-percha/AH Plus and the Resilon/Epiphany System, when submitted to two filling techniquesVeríssimo, Denusa Moreira January 2007 (has links)
VERÍSSIMO, Denusa Moreira. Comparação da infiltração apical entre canais obturados com guta-percha/AH Plus e o sistema Resilon/Epiphany quando submetidos a duas técnicas de obturação. 2007. 109 f. Dissertação (Mestrado em Odontologia) - Universidade Federal do Ceará. Faculdade de Farmácia, Odontologia e Enfermagem, Fortaleza, 2007. / Submitted by denise santos (denise.santos@ufc.br) on 2011-12-08T11:54:38Z
No. of bitstreams: 1
2007_dis_dmveríssimo.pdf: 4142487 bytes, checksum: 55bbe546b889dd8b2532100208b590cf (MD5) / Approved for entry into archive by Eliene Nascimento(elienegvn@hotmail.com) on 2012-02-01T12:43:40Z (GMT) No. of bitstreams: 1
2007_dis_dmveríssimo.pdf: 4142487 bytes, checksum: 55bbe546b889dd8b2532100208b590cf (MD5) / Made available in DSpace on 2012-02-01T12:43:40Z (GMT). No. of bitstreams: 1
2007_dis_dmveríssimo.pdf: 4142487 bytes, checksum: 55bbe546b889dd8b2532100208b590cf (MD5)
Previous issue date: 2007 / The purpose of this study was to compare the level of apical leakage between canals filled with gutta-percha/AH Plus (GP) and the Resilon/Epiphany System (RES), when submitted to two filling techniques, and to observe, through the use of Optic Microscopy (OM), the adaptation of these materials to the dentinal walls in carried through transversal cuts to 4 mm of the apex. For the evaluation of leakage, seventy extracted human teeth were instrumented and randomly divided into 4 experimental groups in accordance with the material and technique used (lateral condensation and Hybrid technique - HT), and two control groups (positive and negative). After 7 days in an oven (37° C, humidity of 100%), the teeth were immersed in Indian ink and cleared. Leakage was measured by the NIH imageJ program. The exact Fisher test was used to make the comparison between the non-leakage percentages and the non-parametric Mann-Whitney test to measure the leakage when there was any. The value p<0.05 was considered to be statistically significant. With regard to the presence of leakage, there was no difference between the filling techniques (p>0.05), but there was a statistically significant difference when RES was compared with GP (p<0.05), which leaked more than RES. With RES, leakage was confined to the apical third and HT could be used to thermo-plasticize RES with satisfactory results. It was observed through the analysis in OM of 20 remaining teeth, filled in the same way that the experimental groups (5 teeth for each group), that the RES presented many areas mismatch between the material and the dentinal walls, what it would justify occurred leaking with this material. / O propósito deste estudo in vitro foi comparar o nível de infiltração apical entre guta-percha/AH Plus (GP) e Sistema Resilon/Epiphany (SRE) quando submetidos a duas técnicas de obturação, e observar, através do uso de Microscopia Óptica (MO), a adaptação destes materiais às paredes dentinárias em cortes transversais realizados a 4mm do ápice. Para a avaliação da infiltração, 70 raízes de dentes humanos extraídos foram instrumentadas e divididas aleatoriamente em quatro grupos experimentais de acordo com o material e técnica empregados (condensação lateral e técnica Híbrida-TH) e dois grupos controles (positivo e negativo). Após sete dias em estufa (37°C, umidade de 100%), as raízes foram imersas em tinta nanquim (7 dias) e diafanizadas. A infiltração linear foi medida através do programa NIH imageJ. Utilizou-se o teste exato de Fisher, para a comparação entre percentual de não-infiltração e teste não-paramétrico de Mann-Whitney, para testar o comprimento de infiltração, quando esta existiu. O valor de p<0,05 foi considerado ser estatisticamente significante. Na presença de infiltração, não houve diferença entre as técnicas de obturação empregadas (p>0,05), mas houve diferença estatisticamente significante quando o SRE foi comparado à GP (p<0,05), que apresentou maior infiltração. Concluiu-se que a infiltração com o SRE ficou confinada ao terço apical e a TH pode ser utilizada para termoplastificação do SRE com resultados satisfatórios. Observou-se através da análise em MO dos 20 dentes restantes, obturados da mesma forma que os grupos experimentais (cinco dentes para cada grupo), que o SRE apresentou muitas áreas de desadaptação entre o material e as paredes dentinárias, fato que justificaria a infiltração ocorrida com esse material.
|
72 |
Nanoinfiltração e manchamento superficial de facetas diretas de resina compostaDiaz, Sheila Francesca Rabanal January 2017 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2017. / Made available in DSpace on 2017-05-31T14:18:09Z (GMT). No. of bitstreams: 1
345988.pdf: 3518006 bytes, checksum: 67aafb150b62a10d71aaf83c5bbc7225 (MD5)
Previous issue date: 2017 / O objetivo do presente estudo in vitro foi comparar a adaptação em esmalte e dentina, o selamento marginal e o nível de manchamento superficial de 2 resinas compostas de diferentes percentuais de contração de polimerização (Charisma Diamond e Filtek Z350) em facetas diretas de resina composta depois de serem submetidas a pigmentação extrínseca e ciclagem térmica. Trinta e dois incisivos inferiores, preparados para receber facetas diretas de resina composta foram divididos aleatoriamente em 4 grupos (n= 8): os Grupos 1 e 3 foram restaurados com resina composta nanohíbrida de baixa contraçao de polimerizaçao e os grupos 2 e 4 foram restaurados com resina composta nanoparticulada (com contraçao de polimerizaçao normal). Com o objetivo de avaliar o nível de manchamento superficial, os Grupos 1 e 2 foram armazenados em vinho tinto por 14 dias a 37°C e foram registrados fotograficamente antes e após a pigmentação extrínseca. Os registros fotográficos foram anexados a questionários de avaliação, submetidos a 2 examinadores voluntários (cirurgiões-dentistas). A seguir, os espécimes dos 4 grupos foram submetidos a 5.000 ciclos térmicos, a nanoinfiltração foi observada usando microscopia eletrônica de varredura (MEV), no modo retroespalhado e com espectometria de energia dispersiva. a percentagem de nanoinfiltração de partículas de prata na interface dente/restauração foi calculada usando um programa de análise digital de imagens. Os resultados foram tabulados e analisados estatisticamente por ANOVA e pelos testes de Kruskal Wallis e Mann Withney, com nível de significância de a =0,05. Observou-se que houve diferença significativa entre a infiltração na margem cervical (dentina) e infiltração total nos quatro grupos, assim como, diferença significativa entre a margem incisal (esmalte) e na margem cervical (dentina) em todos os grupos. Foi observado absorção de prata na margem cervical em todos os grupos, com maior percentagem de infiltração encontrada no Grupo 1. Não houve diferença estatística significativa entre os grupos da margem incisal (esmalte). As facetas diretas de resina composta nanoparticulada apresentaram melhor selamento em esmalte e dentina quando comparados com resina composta nanohíbrida. A resistência ao manchamento superficial parece ser semelhante em ambos as resinas compostas. Oconsumo simulado de vinho causa manchamento superficial nas facetas de resina composta.<br> / Abstract : The aim of this in vitro study was to compare the adaptation to enamel and dentin, the marginal sealing and the level of surface staining of 2 composite resins of different percent polymerization shrinkage (Charisma Diamond and Filtek Z350) in direct composite laminate veneers after being subjected to extrinsic pigmentation and thermal cycling. Thirty-two mandibular incisors, prepared to receive direct composite laminate veneers, were randomly divided into 4 groups (n = 8): Groups 1 and 3 were restored with a nanohybrid composite resin and Groups 2 and 4 were restored with a nanoparticulate composite resin. In order to evaluate the degree of surface staining, Groups 1 and 2 were stored in red wine for 14 days at 37 °C and were photographed before and after extrinsic pigmentation. The photographic records were attached to 5 evaluation scores, submitted to 2 voluntary examiners (dental surgeons). The specimens of the four groups were sectioned and immersed into silver nitrate solution after aging with 5,000 thermocycles. Nanoleakage was observed using a scanning electron microscopy (SEM), in both backscattered electron mode and EDX spectrometry dispersive mode; the percentage distribution of silver particles at the restoration/tooth interface was calculated using a digital image analysis software. The results were plotted and analyzed statistically using one-way ANOVA, and Kruskal Wallis and Mann Whitney?s tests. The level of significance was set to a =.05. Statistically significant differences were observed between dentin infiltration and total infiltration in the four groups, as well as, significant differences between enamel and dentin in all groups. It was observed clear silver uptake at the cervical margin in the four groups, with the highest microleakage percentage found in Group 1. No significant differences were observed in enamel between the four Groups. Direct composite laminate veneers of nanoparticles resin, presented better enamel and dentine adaptation when compared with direct composite laminate veneers of nanohybrid resin. The resistance to surface staining seemed to be similar in both tested groups.
|
73 |
Características de infiltração de amostras do solo residual do granulito-gnaisse percolados por água e efluente tratado de esgotoBatista, Joaz de Souza 17 December 2009 (has links)
Submitted by LIVIA FREITAS (livia.freitas@ufba.br) on 2016-01-06T13:54:25Z
No. of bitstreams: 2
CAPA DA D[19]...pdf: 407376 bytes, checksum: 3f58e720b82a4b84337ea67649fca226 (MD5)
Dissertação dada como ok pelos examinadores 12_12_10.pdf: 3467757 bytes, checksum: 35c21af5fd30f058706293c68aa15fd4 (MD5) / Approved for entry into archive by LIVIA FREITAS (livia.freitas@ufba.br) on 2016-01-12T16:58:17Z (GMT) No. of bitstreams: 2
CAPA DA D[19]...pdf: 407376 bytes, checksum: 3f58e720b82a4b84337ea67649fca226 (MD5)
Dissertação dada como ok pelos examinadores 12_12_10.pdf: 3467757 bytes, checksum: 35c21af5fd30f058706293c68aa15fd4 (MD5) / Made available in DSpace on 2016-01-12T16:58:17Z (GMT). No. of bitstreams: 2
CAPA DA D[19]...pdf: 407376 bytes, checksum: 3f58e720b82a4b84337ea67649fca226 (MD5)
Dissertação dada como ok pelos examinadores 12_12_10.pdf: 3467757 bytes, checksum: 35c21af5fd30f058706293c68aa15fd4 (MD5) / Discorre-se sobre características de infiltração de amostras do horizonte I-C do solo residual do granulito-gnasse predominante no sítio urbano de Salvador – BA. O estudo avalia e compara as características do solo nos estados indeformado e compactado,obtidas em laboratório, em situações nas quais o fluido percolante é a água ou um efluente sanitário tratado. Um infiltrômetro foi desenvolvido adaptando-se os padrões da norma ASTM D 4874 (1995). Os ensaios foram executados estendendo a rotina usual do ensaio clássico de permeabilidade medindo-se a quantidade de água ou efluente tratado que percolava durante a fase de saturação dos corpos de prova (infiltração não saturada). Em seguida, após a saturação, os mesmos CP foram submetidos ao ensaio convencional
de permeabilidade (infiltração saturada). Numa terceira etapa, os CP foram expostos a
diferentes períodos de drenagem e posteriormente fatiados transversalmente,
determinando-se a umidade de cada fatia de modo a se obter o perfil de umidade ao
longo da altura de cada CP. A análise desses perfis permitiu verificar a ocorrência de
equalização da umidade e avaliar se o valor da umidade equalizada poderia ser associado à capacidade de campo (CC) do solo. Em adição, realizou-se um ensaio de colmatação, por um período de 10 meses, utilizando-se um corpo de prova indeformado percolado pelo efluente tratado. Os resultados indicaram que a amostra colmatou com o tempo. Os resultados dos ensaios de infiltração apresentaram-se coerentes com o fenômeno e os modelos teóricos referidos na literatura. As curvas de infiltração mostraram boa repetibilidade. A partir dos resultados obtidos nos ensaios de infiltração não saturada foi possível avaliar quantitativamente a constante “ ”, associada à sucção matricial do solo, parte integrante dos modelos propostos por Green-Ampt (1911) e Phillip (1954a). Foram obtidos valores variáveis e decrescentes para “ ”, da ordem de 24 a 259 cmca (centímetro de coluna de água) no início da infiltração (
i), e da ordem de 14 a 67 cmca quando a infiltração atingia a base do CP. Tais valores estão em conformidade com os referidos na literatura abrangida, a exemplo dos valores obtidos por Wang (1995)
em seus estudos experimentais. Os valores de possibilitaram a formulação da equação de infiltração do solo residual estudado, para qualquer carga hidráulica (Dp) atuante. O autor não tem conhecimento do valor de ter sido determinado precedemente para o solo residual predominante no sítio urbano de Salvador.
|
74 |
Propriedades geomecânicas de um solo compactado com vermiculita para fins de cobertura em aterro de resíduosVieira, Kristian Sales [UNESP] 26 February 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:15Z (GMT). No. of bitstreams: 0
Previous issue date: 2013-02-26Bitstream added on 2014-06-13T18:29:47Z : No. of bitstreams: 1
vieira_ks_me_bauru.pdf: 16912396 bytes, checksum: 7f7137cb4315617223caa084b8a92d39 (MD5) / A cobertura final de um aterro de resíduos se dá quando a última célula alcança sua cota mais alta. Os principais objetivos da cobertura final em aterros são: minimizar a infiltração de água de chuva, limitar a emissão descontrolada de gases proveniente da decomposição dos resíduos, suprimir a proliferação de vetores, fornecer uma superfície adequada para a revegetação e servir como o elemento central na recuperação do local. Esta pesquisa tem o propósito de analisar as características geotécnicas (mecânicas e hidráulicas) de um solo residual maduro de biotita gnaisse compactado como vermiculita expandida verificando a aplicabilidade desta mistura para construção de cobertura de aterros de resíduos. A vermiculita é um material inodoro, não abrasivo e não carcinogênico e suas propriedades de superfície, em especial a porosidade e carga superficial negativa, promovem a esta material alto poder de absorvente e carreador de nutrientes. Incialmente foram realizados ensaios de absorção de água e de secagem ao ar em amostras compactadas com diferentes porcentagens em volume de vermiculita acrescentada ao solo. Os resultados preliminares mostraram que a relação vermiculita/solo na razão de 40% em volume de solo compactado apresentou um melhor resultado para os testes realizados. A absorção de água atingiu 51% quando comparada ao solo natural (14%) e com relação à perda de massa esta mesma mistura apresentou uma estabilidade de 72 horas a umidade absorvida enquanto o solo natural após 24 horas de secagem ao ar a umidade inicial já havia sico alcançada. Também foram realizados ensaios complementares tais como curva característica, ensaio de compressão diametral e compressão simples, compressibilidade e adensamento, resistência ao cisalhamento direto, permeabilidade e ensaio de formação de trinca... / The final cover for a landfill of waste occurs when the last cell reaches its highest elevation, and he main objectives of this cover are: to minimize infiltration of rainwater, to limit the uncontrolled emission of gases of gases from the decomposition of waste, to suppress the proliferation of vectors, to provide a suitable surface for revegetation and serving as the central element in the recovery site. This study aims to analyze the geotechnical characteristics (mechanical and hydraulic) of soil residual biotite gneiss mature compacted with expanded vermiculite and to verify the applicability of this mixture for construction in waste landfill cover. Vermiculite is a odorless, non-abrasive, non-carcinogenic material, in addition their surface properties, in particular the porosoty and surface charge negative, make this material a high power of absorving and nutrient carrier. Initially, were performed tests by water absorption and drying compressed air in samples with different percentages by volume of vermiculite added to the soil. Preliminary results showed that the vermiculite/soil ratio of 40% by volume of compacted soil was better for the tests. The water absorption reached a value of 51% compared to the natural soil (14%) and with about the mass loss, that same mixture showed a stability of 72 hours of the absorved moisture while the natural soil, after 24 hours by drying the initial moisture content had already been achieved. Then, were conducted additional tests such as the characteristic curve, diametral compreension test, simply compressive compressibility and density, direct shear strength, permeability and formation tests crack. Considering the results presented, the use of expanded vermicule to the soil compacted presents itself as a alternative for a final landfill of waste cover
|
75 |
Avaliação da interface de cinco sistemas de implantes e seus respectivos abutments com auxílio do método de microscopia eletrônica de varreduraFujiwara, Carlos Alberto [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:42Z (GMT). No. of bitstreams: 0
Previous issue date: 2005Bitstream added on 2014-06-13T20:55:05Z : No. of bitstreams: 1
fujiwara_ca_me_araca.pdf: 1023210 bytes, checksum: d5bfe58a6ad917370b05a41403af9e6f (MD5) / Universidade Estadual Paulista (UNESP) / A adaptação entre a plataforma do implante e seu respectivo abutment deve ser precisa, isto é, sem nenhuma fenda, que é denominada microgap, entre as estruturas. A presença do microgap permite que microorganismos presentes na microbiota bucal migrem para o interior do implante, o que pode ocasionar problemas de natureza inflamatória e ou infecciosa, e, conseqüentemente, causar a perda do implante. Neste estudo utilizamos uma amostragem de 26 (vinte e seis) implantes e seus respectivos abutments provenientes de 5 (cinco) marcas comerciais diferentes: AS Tecnology, Conexão Sistema de Prótese, Neodent Implante Osteointegrado, Sterngold Implamed, e 3i Implant Innovation. Os abutments receberam um torque de 20Ncm. Os cortes longitudinais da interface implante/abutment foram mensurados em 6 (seis) locais com o auxílio da microscopia eletrônica de varredura. Os resultados das mensurações foram submetidos à análise estatística. Foi possível concluir que: 1) A seqüência dos grupos, em relação ao gap encontrado, do menor para o maior, foram: abutment cônico, abutment gold ucla, abutment mult unit. 2) O abutment cônico e o abutment mult unit apresentaram gaps menores que o abutment gold ucla. 3) O ponto interno apresentou gap menor em relação ao ponto médio, o qual foi menor que o ponto externo, portanto, as peças tenderam a convergir para o ponto interno. / The adaptation of the implant platform and its respective abutment must be precise, with no space denominated microgap, between the structures. The presence of a microgap allows microorganisms that are present in the buccal microbiology to migrate into the implant, what could cause inflammatory and/or infectious problems, and consequent loss of the implant. In this study, a sample of 26 (twenty six) implants and their respective abutments was taken: conic, multi unit, and the gold ucla - together with their respective fixing screws. The abutments received a manual torque of 20Ncm. After the manual preparation, the interface implant/abutment longitudinal cuts were measured on 6 (six) different points through an Scanning Electron Microscope (SEM). The results of such measurements were statistically analyzed, and according to the experimental conditions of this study, was possible to conclude: 1) The sequential groups of implants/abutments, in relation to the gap found, from the smaller to the biggest, were: a) conic abutment , b) gold ucla abutment , c) multi unit abutment. 2) The conic and the multi unit abutments showed smaller gaps than the gold ucla abutments. 3) The internal point showed a smaller gap than the middle point, and the middle point, in return, also showed a smaller gap in relation to the external point; therefore, the pieces tended to converge to the internal point.
|
76 |
Infiltração marginal em cavidades de classe V. Efeito de sistema adesivo e preparo cavitárioAraújo, Taylane Soffener Berlanga de [UNESP] 15 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0
Previous issue date: 2005-12-15Bitstream added on 2014-06-13T19:01:40Z : No. of bitstreams: 1
araujo_tsb_dr_arafo.pdf: 876638 bytes, checksum: 4edaacd253f53829f5fdb7d87cab5c0b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo teve por objetivo analisar in vitro a influência de dois sistemas adesivos resinosos, sendo um autocondicionante de dois passos (Clearfil SE Bond 2) e um convencional também de dois passos (Master Bond), bem como o tratamento das margens cavitárias no controle da microinfiltração marginal. Preparos cavitários de classe V foram executados na face vestibular em 80 dentes anteriores bovinos previamente extraídos, divididos em oito grupos (n=10). O grau de infiltração marginal foi avaliado por penetração do agente traçador (Nitrato de Prata (AgNO3) a 50%) nas paredes incisal e cervical por meio de um Software-Image Tool, no qual se mede o grau de infiltração em micrômetros e, portanto, análise quantitativa, os resultados submetidos à Análise de Variância seguida do teste de Tukey para observação das diferenças, concluindo-se que: a) os sistemas adesivos apresentaram estatisticamente o mesmo comportamento; b) existe diferença estatisticamente significante entre as técnicas de preparos utilizados sendo que os preparos realizados nos Grupo I e Grupo II, bem como nos Grupos VII e VIII, apresentaram comportamento semelhante e os melhores resultados para redução da microinfiltração; c) os preparos do Grupo III e Grupo IV apresentaram maiores índices de microinfiltração marginal, no entanto, semelhantes aos Grupos V e VI; d) a região cervical apresentou maior nível de microinfiltração quando comparada com a região incisal. / This study aimed to analyse in vitro the influence of two resinous adhesive systems: one self-etching of two steps (Clearfil SE Bond 2) and one also conventional of two steps (Master Bond), as well as the treatment of the cavity margins in the marginal microleakage control. Cavity preparations of class V were carried out on the buccal surface of 80 bovine anterior teeth, previously extracted, divided into eight groups (n=10). The marginal leakage degree was evaluated by the penetration of the tracer agent (Silver Nitrate (AgNO3) at 50%); on the incisor and cervical walls through a Software-Image Tool that measures the leakage degree in micrometers and, therefore, quantitative analysis, which results were subjected to the Variance Analysis and afterwards to the Tukey's test in order to observe the differences it was possible to conclude that: a) the adhesive systems presented statistically the same behaviour; b) there is a statistically meaningful difference between the preparation techniques that were used and the preparations that were carried out in Group I and Group II, as well as Groups VII and VIII, that presented similar behaviour and the best results for the reduction of microleakage; c) the preparations of Group III and Group IV presented higher rates of marginal microleakage, however, they were similar to Groups V and VI; d) the cervical region presented higher level of microleakage comparing to the incisor region.
|
77 |
Análise comparativa da infiltração marginal em restaurações de classe II em resina composta com diferentes técnicas de inserçãoMacedo, Ricardo Prates [UNESP] 01 December 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0
Previous issue date: 2004-12-01Bitstream added on 2014-06-13T20:41:43Z : No. of bitstreams: 1
macedo_rp_dr_arafo.pdf: 474447 bytes, checksum: 4d9c167f257a4293018ed19aaa516902 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho, estudou-se a influência de quatro diferentes técnicas de inserção (Incremental, Única, Beta-quartzo e Pré-polimerizada) da resina composta fotoativada em dois tamanhos de cavidades classe II, no vedamento marginal, através de testes de infiltração de um agente corante. As cavidades foram preparadas em dentes molares humanos extraídos, com a parede cervical localizada em cemento. Os materiais (adesivo dentinário e resina composta) foram de uma mesma marca comercial. Realizadas as restaurações, os dentes foram submetidos à termociclagen (5o C e 55o C, durante 500 ciclo) e depois de adequadamente impermeabilizados, foram imersos em solução corante Rodamina a 5% por uma semana. Em seguida, os dentes foram cortados e avaliados, quanto à microinfiltração na interface parede gengival e material restaurador, por dois examinadores, segundo um critério pré-estabelecido (graus de 0 a 3). Após a análise dos resultados, foi possível concluir que: a técnica incremental em esmalte (Grupo 1B e 2B) foi a que apresentou os menores níveis de infiltração marginal, logo a que produziu o melhor vedamento marginal. A técnica incremental em cemento (Grupo 1C) apresentou resultados intermediários, não sendo estatisticamente diferente dos grupos 1B e 2B. A técnica com inserção de Beta Quartz Inserts (Grupos 1E e 2E), e técnica de inserção de pérolas pré-polimerizadas de resina (Grupos 1F e 2F) foram as menos efetivas em impedir a infiltração marginal. A confecção de um bisel chanfrado parece desempenhar importante papel na qualidade das margens das restaurações. / This study had the purpose of evaluating the influence of four different techniques of insertion of composite resin (Incremental, Single, Beta-quartz inserts nd Pre-cured) in two sizes of Class II cavities, regarding marginal sealing when submitted to leakage tests using a dying agent. Cavities were prepared in extracted human molars, presenting the cervical wall in the cementum area. Materials used (adhesive and composite resin) were from the same manufacturer. After the restorations were done, teeth were subjected to thermo cycling (5º C e 55º C, for 500 cycles), and then carefully coated with nail polish before submersed in a 5% Rodamine, for the period of one week. Teeth were then sectioned and evaluated to microleakage, at the interface gingival wall and restorative material, by two evaluators following pre-determined criteria (from 0 to 3). After analyzing the results it was possible to conclude that: incremental technique in enamel (Group 1B e 2B) presented the lowest levels of marginal leakage or the best marginal sealing. The incremental technique for the cementum group (Group 1C) presented intermediary results, not statistically different from group 1B e group 2B. The techniques using Beta Quartz Inserts (Groups 1E e 2E), and pre-cured pellets of resin (Groups 1F e 2F) were the least effectives in preventing the marginal leakage. The preparation of a chamfered bevel seemed to play an important role in the quality of the margins of the restorations.
|
78 |
Avaliação da vulnerabilidade natural à contaminação do solo e aqüífero do reservatório Batatã - São Luís (MA)Pereira, Ediléa Dutra [UNESP] 24 February 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:18Z (GMT). No. of bitstreams: 0
Previous issue date: 2006-02-24Bitstream added on 2014-06-13T18:43:30Z : No. of bitstreams: 1
pereira_ed_dr_rc.pdf: 15244151 bytes, checksum: 5d28e00ee5e35bb5193384bfee2aec57 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O mapeamento geológico-geotécnico em áreas urbanas foi utilizado na análise das características do meio físico e processos geológicos, avaliando suas limitações e potencialidades como subsídio à gestão e ao planejamento municipal. A Bacia do Rio Bacanga, localizada na Ilha do Maranhão, no município de São Luis-Maranhão (Brasil), apresenta uma área de 106 km2 que através dos tempos vem passando por um dinâmico processo de ocupação de forma não planejadas, provocando diversos impactos ambientais como assoreamento dos mangues, desmatamentos, aterramentos, impermeabilizações do solo, erosão, contaminação da água, inundações e outros. Os recursos hídricos genuinamente luduvicense são estratégicos para a Ilha oceânica, como reservas que precisam ser preservadas por se tratar de um ecossistema frágil. O estudo foi realizado através do método do detalhamento progressivo (análise do geral para o particular) para determinação e avaliação de áreas vulneráveis a contaminação do solo e da água no Reservatório Batatã. Na etapa geral do método foi elaborado o mapa geológico-geotécnico na escala 1:20.000 onde foram individualizada 6 unidades no terreno. Na etapa de semi-detalhe a pesquisa se direcionou para o estudo da vulnerabilidade natural à contaminação do solo e aqüífero do Reservatório Batatã e entorno. Nesta etapa, os estudos enfocaram uma área de 6,6 km2, para a qual foram geradas cartas na escala de 1:10.000: de declividade, de profundidade do nível de água subterrânea, de superfície potenciométrica do aqüífero livre Barreiras, de material inconsolidado e de uso e ocupação do solo. Nesta etapa, utilizou-se o método de avaliação da vulnerabilidade natural GOD utilizando-se as informações das cartas de unidades de material inconsolidado e da profundidade do nível de água subterrânea sendo gerado o mapa de vulnerabilidade... / The geological-geotechnical mapping in urban areas was used in the analysis of the environment characteristics and geological processes, evaluating its limitations and potentialities as subsidy to the municipal management and planning. The Basin of the river Bacanga is located in the Maranhão lsland, in the city of São Luis - Maranhão (northeast of Brazil) and presents an area of 106 km2. lt has been passing through a dynamic process of non-planned human occupation which has caused many impacts as mangroves landfill environmental in region, deforestation, ground waterproofing, erosion, water contamination, flooding and others. Local water resources constitute a fragile ecosystem but a strategic one for such an oceanic island. Therefore, it must be preserved. The study was done through the method of the gradual detailing (it analyzes first the general aspects and afterwards the specific ones) for determination in the Batatã Reservoir. On Lhe first and most general step, a 1:20.000 scale geologic-geotechnical map was made, on where six land units were set up. The semi-detailed step studied the natural vulnerability to ground and aquifer contaminaton of the Batatã Reservoir and its surroundings. Such stage focused a 6.6 km2 area for which 1:10.000 scale charts were generated: declivity, underground water level depth, potentiometric surface, unconsolidated material and ground occupation. At this phase, the GOD natural vulnerability evaluation approach was used, and then information from the land unit charts of unconsolidated material and underground water level depth was utilized, resulting a map of natural vulnerability concerned to the contamination of ground and aquifer. The map of ground occupation was overlapped on the natural vulnerability map, resulting a map of natural vulnerability and potential contamination of the ground and aquifer of the Batatã Reservoir... (Complete abstract, click electronic address below)
|
79 |
Avaliação da microinfiltração bacteriana nas interfaces entre pilares e implantesFaria, Renata [UNESP] 15 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-08-15Bitstream added on 2014-06-13T18:46:02Z : No. of bitstreams: 1
faria_r_dr_sjc.pdf: 634063 bytes, checksum: f7c76bd8def68214cb43267b9a499d76 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo nesta pesquisa foi avaliar a infiltração bacteriana in vitro na interface entre o pilar e o implante, comparando-se três tipos de conexões protéticas: Hexágono Externo (HE), Hexágono Interno Indexado (HII) e Cone Morse (CM). Sob condições estéreis, foi inoculada colônia de Escherichia coli na porção apical do parafuso do pilar. Após, os pilares foram fixados aos implantes com torque de 20 N/cm. Foram descartadas as amostras que apresentaram contaminação externa imediata. As amostras foram colocadas em tubos de ensaios contendo 2 ml de caldo TSB estéril. Em acompanhamento diário, por 7 dias, os caldos que se apresentaram turvos foram semeados em placa de petri com TSA e incubados em estufa bacteriológica à 37oC por 24 horas, para a observação de crescimento bacteriano. Coloração Gram foi realizada tanto no caldo quanto na colônia resultante da semeadura, para comprovação da presença de E. coli (Gram-negativo). Ao final do período, todas as amostras foram separadas, o conteúdo interno foi coletado com cone de papel e solução salina e semeado em placas de petri contendo TSA, levadas à estufa bacteriológica a 37º C por, 24 horas para verificar a viabilidade das bactérias. As amostras que não continham E.coli viáveis no seu interior foram descartadas do resultado final. Após os descartes por contaminação externa e inviabilidade, obtiveram-se os seguintes números de amostra: 38 (HE), 40 (HII) e 41 (CM). Os resultados, em % de amostras com infiltração bacteriana, foram submetidos ao teste de comparações múltiplas de proporções. As curvas de sobrevivência foram analisadas pelo método de Kaplan-Meyer e comparadas pelo teste estatístico de Log-Rank. Não houve diferença entre HE (10,53%), HII (4,88%) e CM (7,50%). As curvas de sobrevivência não diferiram entre si. A infiltração bacteriana ocorreu de modo... / The aim of this study was to evaluate, in vitro, the bacterial leakage between implant and abutment comparing three kinds of implantabutments connections: extern hexagon (EH), indexed intern hexagon (IIH) and morse-taper (MT). Under sterile controlled conditions, the tip of the abutment screw was inoculated with Escherichia coli culture and then the abutment was placed in position and tightened (20N/cm). The specimen was discarded if an external contamination of the outer surface was observed. Each specimen was incubated in a glass tube containing 2mL of sterile TSB medium at 37oC. The growth of E. Coli in the medium was registered every 24h. Once the sample showed cloudy broth, it was individually plated on TSA plates and incubated in an anaerobic chamber at 37oC for 24h, in order to observe the bacterial growth. Gram test was performed both in the medium and in the culture to certify the presence of E. Coli (Gram negative). After 7 days, each test specimen was sampled using a sterile paper point which was incubated in TSA plates and incubated in anaerobic chamber at 37oC for 24h, to verify bacterial viability. Samples that did not show bacterial viability in the end of the study were eliminated from the final results. After that, there were 38 EH samples, 40 IIH samples and 41 CM samples. The results, in %, of bacterial leakage, were statistically evaluated by multiple comparisons for proportion. The survival curves were analyzed by Kaplan-Meyer method and compared by statistical test of Log-Rank. There was no statistical difference among EH (10,53%), IIH (4,88%) e MT (7,50%). The three survival curves did not differ (p>0.005). It was conclude that the bacterial leakage occurred in a similar way for the three kinds of implant-abutment interface, no matter the assembly configuration.
|
80 |
Infiltração bacteriana nas interfaces entre implantes e pilares: efeito do desenho das conexões protéticasLima, Elen Guerra de [UNESP] 10 February 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:52:55Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-02-10Bitstream added on 2015-05-14T16:59:42Z : No. of bitstreams: 1
000823415.pdf: 1046424 bytes, checksum: 9f8cfb9c1c9a64a37fcfcc7f83233086 (MD5) / O objetivo do estudo foi avaliar a microinfiltração bacteriana in vitro na interface entre o pilar e o implante, comparando-se Hexágono Externo (HE), Hexágono Interno (HI), Conexão Cônica (CC), sendo esta última de 3 tipos diferentes de desenho dos componentes protéticos. Para tal, 150 conjuntos (pilar/implante) foram utilizados, divididos em cinco grupos (n = 30). G1 - pilares HE; G2 - pilares HI; G3 - pilares CC do tipo sólido; G4 - pilares CC do tipo indexado; G5 - pilares CC do tipo linha zero. Para a avaliação, suspensão das bactérias Escherichia coli (ATCC 25922) e Streptococcus sanguinis (ATCC 10557) foram inoculadas na porção apical do parafuso do pilar, sob condições estéreis. Os pilares foram fixados aos implantes e torqueados segundo recomendações do fabricante, e imersos em caldo BHI estéril durante 14 dias. Ao final do período, os conjuntos foram separados, o conteúdo interno foi sonicado, diluído, semeado e levado a estufa bacteriológica (37 ºC por 48 horas) para verificação da viabilidade e contagem das bactérias. As amostras que não continham E. coli e S. sanguinis viáveis, foram descartadas do estudo. A morfologia bacteriana foi ainda observada em microscopia eletrônica de varredura (MEV). Os resultados, em % e unidades formadoras de colônias (UFCs) foram analisados por teste estatístico ANOVA 1 fator. Não houve diferença estatística entre G2 (9,09%), G3 (21,74%), G4 (22,73%) e G5 (11,11%). Analisando-se separadamente os grupos não-turvados com E. Coli (p = 0,126) e S. Sanguinis (p = 0,962) e os grupos turvados com E. coli e S. sanguinis (p = 0,655.) com Anova 1- fator (p < 0,05), não houve diferenças significantes na contagem de UFC entre os tipos de conexões / The aim of this study was to evaluate the in vitro bacterial microleakage at the interface between the abutment and the implant, comparing 3 types of prosthetic connections: External Hexagon (EH), Internal Hexagon (IH), Taper Connection (TC), the latter of 3 different types of the design of the abutments. For this, it was utilized 150 sets (abutment / implant), that were divided into 5 groups (n = 30). G1 (Control) - EH abutments; G2 - IH abutments; G3 - TC solid abutments; G4 - TC indexed abutments; G5 - TC zero line abutments. For this evaluation, suspension of the bacterial Escherichia coli (ATCC 25922) e Streptococcus sanguinis (ATCC 10557) were inoculated in the apical portion of the abutment screw, under sterile conditions. The abutments were fixed to the implants and torqued according to manufacturer's recommendations, and immersed in sterile BHI broth for 14 days. At the end of the period all sets were separated, the inner contents was be sonicated, diluted, seeded and taken to a bacteriological incubator (37 °C for 24 hours) to check the viability of the bacteria. The samples that did not contain viable E. coli e S. sanguinis were discarded from the study. The staining and bacterial morphology were observed in optical microscope and scanning electron microscopy (SEM). Results of colony forming units (CFUs) were analyzed by ANOVA 1 factor. There were no differences between the percentage of bacterial infiltration for IH (9.09%), CS (21.74%), CI (22.73%) e C0 (11.11%). Analising separetly the groups non-infritated with E. coli (p = 0,126) and S. Sanguinis (p = 0,962) and the groups infiltrated with E. coli and S. sanguinis (p = 0,655.) (p < 0,05), there no was statistical difference in the count of CFU/ml between the connections type
|
Page generated in 2.5455 seconds