• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 12
  • 6
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Ekonomisk Optimering av Systemtemperaturer i Radiatorsystem / Economy Optimization of System Temperatures in Radiator Systems

Öhlund, Martin January 2020 (has links)
Systemtemperaturer i värmesystem är en debatterad fråga i Sverige. Vid projektering av ett värmesystem har valet av systemtemperatur en avgörande roll för kostnaden av värmesystemet. Frågan vilka systemtemperaturer i värmesystemen som är det mest ekonomiska är viktig för att värmesystemet ska ha en fördel jämfört med konkurrenterna på marknaden. Historiskt sett har systemtemperaturerna i de svenska värmesystemen varit 80/60 medans idag är den vanligaste temperaturerna 55/45. Under 60-talet stod Östen Sandberg som förespråkare för ett nytänkande värmesystem kallat lågflödesystem (LF). Detta värmesystem använder sig av låga flöden i rörledningarna och stora temperaturskillnader på framledningen och returledningen. Förespråkare av dessa lågflödesystem hävdar att vid rätt användning kan en omjustering av det befintliga värmesystemet från ett högflödesystem (HF) till ett lågflödesystem drastigt reducera energiförbrukningen för fastigheten och samtidigt uppnå acceptabla inomhusförhållanden. Hade ett LFsystem kunnat konkurrera mot ett HFsystem ekonomiskt? För att undersöka detta kommer ett 55/45-HFsystem att användas som ursprungsfall vid jämförelser mellan HFsystem och LFsystem med olika systemtemperaturer för att utreda om ett 55/45-HFsystem är det mest ekonomiska värmesystemet. Studien visar många fördelar med 55/45-HFsystemet. Ett 55/45-HFsystem har relativt låga investeringskostnader vid projekteringen i jämförelse med de andra värmesystemen. En annan fördel är att detta värmesystem är kompatibelt med både fjärrvärme samt bergvärme vilket gör detta system passande som ett standardiserat värmesystem. Det mest ekonomiska värmesystemet är ett 80/60-HFsystem, vilket har lägre investeringskostnader för både radiatorer samt rörkostnader. Förespråkare av LFsystem hävdar att de reducerade flödena medför reducerade elkostnader för cirkulationspumpen vilket i längden gör LFsystemet energisnålare. Denna studie visar att de reducerade flödena och dess påverkan av energiförbrukningen hos cirkulationspumpen är förhållandevis så låga i jämförelse med de totala energiförbrukningen hos värmesystemet att den möjliga vinsten är försumbar. Däremot kan de reducerade flödena minska risken för en snedfördelad värmefördelning i fastigheten. LFsystemens stora nackdel är ökade investeringskostnader jämfört med HFsystemen. / The choice of temperatures in heating systems has long been a question for debate in Sweden. For the design engineer, the choice of system temperatures in a heating system has a decisive impact on the cost and in order to stay competitive on the market it is crucial to design the heating system as cost effective as possible. Historically the system temperature in Swedish heating systems has been 80/60 but today we see that the most common temperatures are 55/45. During the 1960´s Östen Sandberg became the leading advocate for a new type of heating system using a low flow principle (LF) for heat distribution. The LF principle requires a larger temperatur difference between the supply and return temperatures for the adequate heating. Advocates of the LF principle claims that large energy savings are possible if an exsisting high flow heating system (HF) undergoes an adjustment to a LF heating system. The question is how accurate is this claim? This article shows many advantages with the nowadays common 55/45-HFsystem. A 55/45-HFsystem has relatively low investment costs in comparison with other types of heating systems. Another advantage is the fact that the 55/45-HFsystem is compatible with both district heating and geothermal heat pump heating systems which makes this radiator system suitable as a standardized system. The most economical radiator system is the 80/60-HFsystem, which has a lower investment cost for both radiators and piping in comparison with a 55/45-HFsystem. The claim that LFsystems and the associated LF principle could result in a reduced energy cost for the heating system was not supported. This article shows that the energy savings that comes from the LF principle is negligible in comparison with the heating systems total energy cost. The LF principle could however reduce the risk of an uneven heating distribution in the building due to a more unpredictable regulation of the flow through the radiators. LFsystem disadvantage is an general overall larger investment cost in comparison with a HFsystem.
12

Högtempererat borrhålslager för fjärrvärme / High Temperature Borehole Thermal Energy Storage for District Heating

Hallqvist, Karl January 2014 (has links)
The district heating load is seasonally dependent, with a low load during periods of high ambient temperature. Thermal energy storage (TES) has the potential to shift heating loads from winter to summer, thus reducing cost and environmental impact of District Heat production. In this study, a concept of high temperature borehole thermal energy storage (HT-BTES) together with a pellet heating plant for temperature boost, is presented and evaluated by its technical limitations, its ability to supply heat, its function within the district heating system, as well as its environmental impact and economic viability in Gothenburg, Sweden, a city with access to high quantities of waste heat. The concept has proven potentially environmentally friendly and potentially profitable if its design is balanced to achieve a good enough supply temperature from the HT-BTES. The size of the heat storage, the distance between boreholes and low borehole thermal resistance are key parameters to achieve high temperature. Profitability increases if a location with lower temperature demand, as well as risk of future shortage of supply, can be met. Feasibility also increases if existing pellet heating plant and district heating connection can be used and if lower rate of return on investment can be accepted. Access to HT-BTES in the district heating network enables greater flexibility and availability of production of District Heating, thereby facilitating readjustments to different strategies and policies. However, concerns for the durability of feasible borehole heat exchangers (BHE) exist in high temperature application. / Värmebehovet är starkt säsongsberoende, med låg last under perioder av högre omgivningstemperatur och hög last under perioder av lägre omgivningstemperaturer. I Göteborg finns en stor mängd spillvärme tillgängligt för fjärrvärmeproduktion sommartid när behovet av värme är lågt. Tillgång till säsongsvärmelager möjliggör att fjärrvärmeproduktion flyttas från vinterhalvår till sommarhalvår, vilket kan ge såväl lönsamhet som miljönytta. Borrhålsvärmelager är ett förhållandevis billigt sätt att lagra värme, och innebär att berggrunden värms upp under sommaren genom att varmt vatten flödar i borrhål, för att under vinterhalvåret användas genom att låta kallt vatten flöda i borrhålen och värmas upp. I traditionella borrhålsvärmelager används ofta värmepump för att höja värmelagrets urladdade temperatur, men på grund av höga temperaturkrav för fjärrvärme kan kostnaden för värmepump bli hög. I denna rapport föreslås ett system för att klara av att nå höga temperaturer till en lägre kostnad. Systemet består av ett borrhålsvärmelager anpassat för högre temperaturer (HT-BTES) samt pelletspannor för att spetsa lagrets utgående fluid för att nå hög temperatur. Syftet med rapporten är att undersöka potentialen för detta HT-BTES-system med avseende på dess tekniska begränsningar, förmåga till fjärrvärmeleverans, konsekvenser för fjärrvärmesystemet, samt lönsamhet och miljöpåverkan. För att garantera att inlagringen av värme inte är så stor att priset för inlagrad värme ökar väsentligt, utgår inlagringen från hur mycket värme som kyls bort i fjärrvärmenätet sommartid. I verkligheten finns betydligt mer värme tillgänglig till låg kostnad. När HT-BTES-systemet producerar fjärrvärme, ersätts fjärrvärmeproduktion från andra produktionsenheter, förutsatt att HT-BTES-systemets rörliga kostnader är lägre. I Göteborg ersätts främst naturgas från kraftvärme, men också en del flis. Kostnadsbesparingen beror på differensen för total fjärrvärmeproduktionskostnad med och utan HT-BTES-systemet. Undersökningen visar att besparingen är större om HT-BTES-systemet placeras i ett område där det är möjligt att mata ut fjärrvärme med lägre temperatur. Om urladdning från HT-BTES kan ske med hög temperatur ökar också besparingen. Detta sker om lagrets volym ökar, om avståndet mellan borrhål minskar eller om värmeöverföringen mellan det flödande vattnet i borrhålen och berggrunden ökar. Dessa egenskaper för lagret leder också till minskade koldioxidutsläpp. Storleken på besparingen beror dock i hög grad på hur bränslepriser utvecklas i framtiden. Strategiska fördelar med HT-BTES-systemet inkluderar; minskad miljöpåverkan, robust system med lång teknisk livslängd (för delar av HT-BTES-systemet), samt att inlagring av värme kan ske från många olika produktionsenheter. Dessutom kan positiva bieffekter identifieras. Undersökningen visar att HT-BTES-systemet har god potential att ge lönsamhet och minskad miljöpåverkan, och att anläggning och drift av lagret kan ske utan omfattande lokal miljöpåverkan. Det har också visats att de geologiska förutsättningarna för HT-BTES är goda på många platser i Göteborg, även om lokala förhållanden kan skilja sig åt. För att nå lönsamhet för HT-BTES-systemet krävs en avvägning på utformning av lagret för att nå hög urladdad temperatur utan att investeringskostnaden blir för stor. Undersökningen visar att om anslutning av HT-BTES-systemet kan ske mot befintlig anslutningspunkt eller till befintlig värmepanna kan investeringskostnaden minska och därmed lönsamheten öka. Placering av HT-BTES-systemet i områden med risk för överföringsbegränsningar kan också minska behovet av att förstärka fjärrvärmenätet, och således bidra till att minska de kostnader som förstärkning av nätet innebär. Betydelsefulla parametrar för att nå lönsamhet för HT-BTES-system inkluderar dessutom kostnaden för inlagrad värme liksom vilket vinstkrav som kan accepteras. Tillgång till HT-BTES möjliggör ökad nyttjandegrad och flexibilitet för fjärrvärmeproduktionsenheter, och därmed ökad anpassningsmöjlighet till förändrade förutsättningar på värmemarknaden. Dock återstår att visa att komponenter som klarar de höga temperaturkraven kan tillverkas till acceptabel kostnad.

Page generated in 0.4444 seconds