1

Monte Carlo particle transport codes for ion beam therapy treatment planning : Validation, development and applications

Böhlen, Till Tobias January 2012 (has links)
External radiotherapy with proton and ion beams needs accurate tools for the dosimetric characterization of treatment fields. Monte Carlo (MC) particle transport codes, such as FLUKA and GEANT4, can be a valuable method to increase accuracy of dose calculations and to support various aspects of ion beam therapy (IBT), such as treatment planning and monitoring. One of the prerequisites for such applications is however that the MC codes are able to model reliably and accurately the relevant physics processes. As a first focus of this thesis work, physics models of MC codes with importance for IBT are developed and validated with experimental data. As a result suitable models and code configurations for applications in IBT are established. The accuracy of FLUKA and GEANT4 in describing nuclear fragmentation processes and the production of secondary charged nuclear fragments is investigated for carbon ion therapy. As a complementary approach to evaluate the capability of FLUKA to describe the characteristics of mixed radiation fields created by ion beams, simulated microdosimetric quantities are compared with experimental data. The correct description of microdosimetric quantities is also important when they are used to predict values of relative biological effectiveness (RBE). Furthermore, two models describing Compton scattering and the acollinearity of two-quanta positron annihilation at rest in media were developed, validated and integrated in FLUKA. The detailed description of these processes is important for an accurate simulation of positron emission tomography (PET) and prompt-γ imaging. Both techniques are candidates to be used in clinical routine to monitor dose administration during cancer treatments with IBT. The second objective of this thesis is to contribute to the development of a MC-based treatment planning tool for protons and ions with atomic number Z ≤ 8 using FLUKA. In contrast to previous clinical FLUKA-based MC implementations for IBT which only re-calculate a given treatment plan, the developed prototype features inverse optimization of absorbed dose and RBE-weighted dose for single fields and simultaneous multiple-field optimization for realistic treatment conditions. In a study using this newly-developed tool, the robustness of IBT treatment fields to uncertainties in the prediction of RBE values is investigated, while comparing different optimization strategies. / <p>At the time of the doctoral defense, the following papers were unpublished and had a status as follows: Paper 5: Submitted. Paper 6: Manuscript.</p>
2

Positron Emission Tomography for the dose monitoring of intra-fractionally moving Targets in ion beam therapy

Stützer, Kristin 26 June 2014 (has links) (PDF)
Ion beam therapy (IBT) is a promising treatment option in radiotherapy. The characteristic physical and biological properties of light ion beams allow for the delivery of highly tumour conformal dose distributions. Related to the sparing of surrounding healthy tissue and nearby organs at risk, it is feasible to escalate the dose in the tumour volume to reach higher tumour control and survival rates. Remarkable clinical outcome was achieved with IBT for radio-resistant, deep-seated, static and well fixated tumour entities. Presumably, more patients could benefit from the advantages of IBT if it would be available for more frequent tumour sites. Those located in the thorax and upper abdominal region are commonly subjected to intra-fractional, respiration related motion. Different motion compensated dose delivery techniques have been developed for active field shaping with scanned pencil beams and are at least available under experimental conditions at the GSI Helmholtzzentrum für Schwerionenforschung (GSI) in Darmstadt, Germany. High standards for quality assurance are required in IBT to ensure a safe and precise dose application. Both underdosage in the tumour and overdosage in the normal tissue might endanger the treatment success. Since minor unexpected anatomical changes e.g. related to patient mispositioning, tumour shrinkage or tissue swelling could already lead to remarkable deviations between planned and delivered dose distribution, a valuable dose monitoring system is desired for IBT. So far, positron emission tomography (PET) is the only in vivo, in situ and non-invasive qualitative dose monitoring method applied under clinical conditions. It makes use of the tissue autoactivation by nuclear fragmentation reactions occurring along the beam path. Among others, +-emitting nuclides are generated and decay according to their half-life under the emission of a positron. The subsequent positron-electron annihilation creates two 511 keV photons which are emitted in opposite direction and can be detected as coincidence event by a dedicated PET scanner. The induced three-dimensional (3D) +- activity distribution in the patient can be reconstructed from the measured coincidences. Conclusions about the delivered dose distribution can be drawn indirectly from a comparison between two +-activity distributions: the measured one and an expected one generated by a Monte-Carlo simulation. This workflow has been proven to be valuable for the dose monitoring in IBT when it was applied for about 440 patients, mainly suffering from deep-seated head and neck tumours that have been treated with 12C ions at GSI. In the presence of intra-fractional target motion, the conventional 3D PET data processing will result in an inaccurate representation of the +-activity distribution in the patient. Fourdimensional, time-resolved (4D) reconstruction algorithms adapted to the special geometry of in-beam PET scanners allow to compensate for the motion related blurring artefacts. Within this thesis, a 4D maximum likelihood expectation maximization (MLEM) reconstruction algorithm has been implemented for the double-head scanner Bastei installed at GSI. The proper functionality of the algorithm and its superior performance in terms of suppressing motion related blurring artefacts compared to an already applied co-registration approach has been demonstrated by a comparative simulation study and by dedicated measurements with moving radioactive sources and irradiated targets. Dedicated phantoms mainly made up of polymethyl methacrylate (PMMA) and a motion table for regular one-dimensional (1D) motion patterns have been designed and manufactured for the experiments. Furthermore, the general applicability of the 4D MLEM algorithm for more complex motion patterns has been demonstrated by the successful reduction of motion artefacts from a measurement with rotating (two-dimensional moving) radioactive sources. For 1D cos2 and cos4 motion, it has been clearly illustrated by systematic point source measurements that the motion influence can be better compensated with the same number of motion phases if amplitudesorted instead of time-sorted phases are utilized. In any case, with an appropriate parameter selection to obtain a mean residual motion per phase of about half of the size of a PET crystal size, acceptable results have been achieved. Additionally, it has been validated that the 4D MLEM algorithm allows to reliably access the relevant parameters (particle range and lateral field position and gradients) for a dose verification in intra-fractionally moving targets even from the intrinsically low counting statistics of IBT-PET data. To evaluate the measured +-activity distribution, it should be compared to a simulated one that is expected from the moving target irradiation. Thus, a 4D version of the simulation software is required. It has to emulate the generation of +-emitters under consideration of the intra-fractional motion, their decay at motion state dependent coordinates and to create listmode data streams from the simulated coincidences. Such a revised and extended version that has been compiled for the special geometry of the Bastei PET scanner is presented within this thesis. The therapy control system provides information about the exact progress of the motion compensated dose delivery. This information and the intra-fractional target motion needs to be taken into account for simulating realistic +-activity distributions. A dedicated preclinical phantom simulation study has been performed to demonstrate the correct functionality of the 4D simulation program and the necessity of the additional, motionrelated input parameters. Different to the data evaluation for static targets, additional effort is required to avoid a potential misleading interpretation of the 4D measured and simulated +-activity distributions in the presence of deficient motion mitigation or data processing. It is presented that in the presence of treatment errors the results from the simulation might be in accordance to the measurement although the planned and delivered dose distribution are different. In contrast to that, deviations may occur between both distributions which are not related to anatomical changes but to deficient 4D data processing. Recommendations are given in this thesis to optimize the 4D IBT-PET workflow and to prevent the observer from a mis-interpretation of the dose monitoring data. In summary, the thesis contributes on a large scale to a potential future application of the IBT-PET monitoring for intra-fractionally moving target volumes by providing the required reconstruction and simulation algorithms. Systematic examinations with more realistic, multi-directional and irregular motion patterns are required for further improvements. For a final rating of the expectable benefit from a 4D IBT-PET dose monitoring, future investigations should include real treatment plans, breathing curves and 4D patient CT images.
3

Partikeltherapie-PET – Optimierung der Datenverarbeitung für die klinische Anwendung

Helmbrecht, Stephan 19 February 2015 (has links) (PDF)
Die Strahlentherapie ist einer der drei Partner im interdisziplinären Feld der Onkologie. In Europa, Asien und den USA besteht zunehmend die Möglichkeit einer Therapie mit Strahlen aus geladenen Ionen anstelle von Photonen. Eine Anlage in Dresden befindet sich in der Kommissionierungsphase. Die Ionenstrahltherapie bietet den Vorteil einer sehr konformalen Behandlung des Tumorvolumens durch die endliche Reichweite der Strahlen und ein ausgeprägtes Dosismaximum kurz vor dem Ende des Strahlpfades. Da eine Therapie in der Regel über bis zu 30 Sitzungen an verschiedenen Tagen durchgeführt wird und der Strahlweg stark von dem durchdrungenen Gewebe beeinflusst wird, sind Verfahren für eine in vivo Verifikation der Strahlapplikation wünschenswert. Eine dieser Methoden ist die Partikeltherapie–Positronen-Emissions-Tomografie (PT-PET). Sie beruht auf der Messung der vom Therapiestrahl erzeugten β+-Aktivitätsverteilung. Da eine direkte Berechnung der Dosis aus der Aktivität in lebendem Gewebe nicht möglich ist, wird die gemessene Aktivitätsverteilung mit einer berechneten Vorhersage verglichen und anschließend entschieden, ob die nächste Therapiesitzung wie geplant erfolgen kann oder Anpassungen notwendig sind. Die vorliegende Arbeit beschäftigt sich mit drei Themen aus dem Bereich der Datenverarbeitung für die PT-PET. Im ersten Teil wird ein Algorithmus zur Bestimmung von Reichweitendifferenzen aus zwei β+- Aktivitätsverteilungen adaptiert und evaluiert. Dies geschieht zunächst anhand einer Simulationsstudie mit realen Patientendaten. Ein Ansatz für eine automatisierte Analyse der Daten lieferte keine zufriedenstellenden Ergebnisse. Daher wird ein Software-Prototyp für eine semiautomatische, assistierte Datenanalyse entwickelt. Die Evaluierung erfolgt durch Experimente mit Phantomen am 12C-Strahl. Die erzeugte Aktivitätsverteilung wird von physiologischen Prozessen im Organismus beeinflusst. Dies führt zu einer Entfernung von Emittern vom Ort ihrer Erzeugung und damit zu einer Verringerung der diagnostischen Wertigkeit der erfassten Verteilung. Zur Quantifizierung dieses als Washout bezeichneten Effektes existiert ein am Tierexperiment gewonnenes Modell. Dieses Modell wird im zweiten Teil der Arbeit auf reale Patientendaten angewendet. Es konnte gezeigt werden, dass das Modell grundsätzlich anwendbar ist und für die betrachtete Tumorlokalisation Schädelbasis ein Washout mit einer Halbwertszeit von (155,7±4,6) s existiert. Die Berechnung der Vorhersage der β+-Aktivitätsverteilung kann durch übliche Monte-Carlo-Verfahren erfolgen. Dabei werden die Wechselwirkungsquerschnitte zahlreicher Reaktionskanäle benötigt. Als alternatives Verfahren wurde die Verwendung gemessener Ausbeuten (Yields) radioaktiver Nuklide in verschiedenen Referenzmaterialien vorgeschlagen. Auf Basis einer vorhandenen Datenbank dieser Yields und einer existierenden Condensed-History-Monte-Carlo-Simulation wird ein Programm zur Berechnung von Aktivitätsverteilungen auf Yieldbasis entwickelt. Mit der Methode kann die β+-Aktivitätsverteilung in Phantomen und Patienten zufriedenstellend vorhergesagt werden. Die entwickelten Verfahren sollen einen Einsatz der PT-PET im klinischen Umfeld erleichtern und damit einen breiten Einsatz ermöglichen, um das volle Potential der Ionenstrahltherapie nutzbar zu machen.
4

Design study of a Compton camera for prompts-gamma imaging during ion beam therapy / Conception d'une caméra Compton pour le contrôle en ligne en hadronthérapie

Richard, Marie-Hélène 04 September 2012 (has links)
L'hadronthérapie est une technique innovante de radiothérapie par ions carbone ou protons visant à améliorer les traitements actuels. La précision balistique accrue renforce la nécessité d'un contrôle du dépôt de dose, si possible en temps réel. Une manière de réaliser ce contrôle est de détecter avec une caméra Compton le gamma prompt émis lors des fragmentations nucléaires pendant l'irradiation du patient. Dans un premier temps, la géométrie de deux types de caméra Compton (double diffusion puis simple diffusion) a été optimisée par simulation Monte Carlo. Cette optimisation a été réalisée en étudiant la réponse des caméras à une source ponctuelle de photons avec un spectre en énergie réaliste. La réponse de la caméra optimisée à l'irradiation d'un fantôme d'eau par un faisceau d'ions carbone ou de protons a ensuite été simulée. Ces simulations ont tout d'abord été confrontées à des mesures effectuées avec un prototype de taille réduite. Ces mesures ont ensuite été utilisées pour évaluer les taux de comptage dans les détecteurs attendus en conditions cliniques. Dans la configuration actuelle de la caméra, ces taux sont élevés et les phénomènes d'empilement risquent d'être problématiques. Enfin, il est démontré que le dispositif étudié est sensible à un déplacement du pic de Bragg de plus ou moins 5 mm malgré les problèmes de coïncidences fortuites et malgré le bruit introduit par l'algorithme de reconstruction utilisé. / Ion beam therapy is an innovative radiotherapy technique using mainly carbon ion and proton irradiations. Its aim is to improve the current treatment modalities. Because of the sharpness of the dose distributions, a control of the dose if possible in real time is highly desirable. A possibility is to detect the prompt gamma rays emitted subsequently to the nuclear fragmentations occurring during the treatment of the patient. In a first time two different Compton cameras (double and single scattering) have been optimised by means of Monte Carlo simulations. The response of the camera to a photon point source with a realistic energy spectrum was studied. Then, the response of the camera to the irradiation of a water phantom by a proton beam was simulated. It was first compared with measurement performed with small-size detectors. Then, using the previous measurements, we evaluated the counting rates expected in clinical conditions. In the current set-up of the camera, these counting rates are pretty high. Pile up and random coincidences will be problematic. Finally we demonstrate that the detection system is capable to detect a longitudinal shift in the Bragg peak of +or- 5 mm, even with the current reconstruction algorithm.
5

Positron Emission Tomography for the dose monitoring of intra-fractionally moving Targets in ion beam therapy

Stützer, Kristin January 2014 (has links)
Ion beam therapy (IBT) is a promising treatment option in radiotherapy. The characteristic physical and biological properties of light ion beams allow for the delivery of highly tumour conformal dose distributions. Related to the sparing of surrounding healthy tissue and nearby organs at risk, it is feasible to escalate the dose in the tumour volume to reach higher tumour control and survival rates. Remarkable clinical outcome was achieved with IBT for radio-resistant, deep-seated, static and well fixated tumour entities. Presumably, more patients could benefit from the advantages of IBT if it would be available for more frequent tumour sites. Those located in the thorax and upper abdominal region are commonly subjected to intra-fractional, respiration related motion. Different motion compensated dose delivery techniques have been developed for active field shaping with scanned pencil beams and are at least available under experimental conditions at the GSI Helmholtzzentrum für Schwerionenforschung (GSI) in Darmstadt, Germany. High standards for quality assurance are required in IBT to ensure a safe and precise dose application. Both underdosage in the tumour and overdosage in the normal tissue might endanger the treatment success. Since minor unexpected anatomical changes e.g. related to patient mispositioning, tumour shrinkage or tissue swelling could already lead to remarkable deviations between planned and delivered dose distribution, a valuable dose monitoring system is desired for IBT. So far, positron emission tomography (PET) is the only in vivo, in situ and non-invasive qualitative dose monitoring method applied under clinical conditions. It makes use of the tissue autoactivation by nuclear fragmentation reactions occurring along the beam path. Among others, +-emitting nuclides are generated and decay according to their half-life under the emission of a positron. The subsequent positron-electron annihilation creates two 511 keV photons which are emitted in opposite direction and can be detected as coincidence event by a dedicated PET scanner. The induced three-dimensional (3D) +- activity distribution in the patient can be reconstructed from the measured coincidences. Conclusions about the delivered dose distribution can be drawn indirectly from a comparison between two +-activity distributions: the measured one and an expected one generated by a Monte-Carlo simulation. This workflow has been proven to be valuable for the dose monitoring in IBT when it was applied for about 440 patients, mainly suffering from deep-seated head and neck tumours that have been treated with 12C ions at GSI. In the presence of intra-fractional target motion, the conventional 3D PET data processing will result in an inaccurate representation of the +-activity distribution in the patient. Fourdimensional, time-resolved (4D) reconstruction algorithms adapted to the special geometry of in-beam PET scanners allow to compensate for the motion related blurring artefacts. Within this thesis, a 4D maximum likelihood expectation maximization (MLEM) reconstruction algorithm has been implemented for the double-head scanner Bastei installed at GSI. The proper functionality of the algorithm and its superior performance in terms of suppressing motion related blurring artefacts compared to an already applied co-registration approach has been demonstrated by a comparative simulation study and by dedicated measurements with moving radioactive sources and irradiated targets. Dedicated phantoms mainly made up of polymethyl methacrylate (PMMA) and a motion table for regular one-dimensional (1D) motion patterns have been designed and manufactured for the experiments. Furthermore, the general applicability of the 4D MLEM algorithm for more complex motion patterns has been demonstrated by the successful reduction of motion artefacts from a measurement with rotating (two-dimensional moving) radioactive sources. For 1D cos2 and cos4 motion, it has been clearly illustrated by systematic point source measurements that the motion influence can be better compensated with the same number of motion phases if amplitudesorted instead of time-sorted phases are utilized. In any case, with an appropriate parameter selection to obtain a mean residual motion per phase of about half of the size of a PET crystal size, acceptable results have been achieved. Additionally, it has been validated that the 4D MLEM algorithm allows to reliably access the relevant parameters (particle range and lateral field position and gradients) for a dose verification in intra-fractionally moving targets even from the intrinsically low counting statistics of IBT-PET data. To evaluate the measured +-activity distribution, it should be compared to a simulated one that is expected from the moving target irradiation. Thus, a 4D version of the simulation software is required. It has to emulate the generation of +-emitters under consideration of the intra-fractional motion, their decay at motion state dependent coordinates and to create listmode data streams from the simulated coincidences. Such a revised and extended version that has been compiled for the special geometry of the Bastei PET scanner is presented within this thesis. The therapy control system provides information about the exact progress of the motion compensated dose delivery. This information and the intra-fractional target motion needs to be taken into account for simulating realistic +-activity distributions. A dedicated preclinical phantom simulation study has been performed to demonstrate the correct functionality of the 4D simulation program and the necessity of the additional, motionrelated input parameters. Different to the data evaluation for static targets, additional effort is required to avoid a potential misleading interpretation of the 4D measured and simulated +-activity distributions in the presence of deficient motion mitigation or data processing. It is presented that in the presence of treatment errors the results from the simulation might be in accordance to the measurement although the planned and delivered dose distribution are different. In contrast to that, deviations may occur between both distributions which are not related to anatomical changes but to deficient 4D data processing. Recommendations are given in this thesis to optimize the 4D IBT-PET workflow and to prevent the observer from a mis-interpretation of the dose monitoring data. In summary, the thesis contributes on a large scale to a potential future application of the IBT-PET monitoring for intra-fractionally moving target volumes by providing the required reconstruction and simulation algorithms. Systematic examinations with more realistic, multi-directional and irregular motion patterns are required for further improvements. For a final rating of the expectable benefit from a 4D IBT-PET dose monitoring, future investigations should include real treatment plans, breathing curves and 4D patient CT images.
6

Partikeltherapie-PET – Optimierung der Datenverarbeitung für die klinische Anwendung

Helmbrecht, Stephan January 2015 (has links)
Die Strahlentherapie ist einer der drei Partner im interdisziplinären Feld der Onkologie. In Europa, Asien und den USA besteht zunehmend die Möglichkeit einer Therapie mit Strahlen aus geladenen Ionen anstelle von Photonen. Eine Anlage in Dresden befindet sich in der Kommissionierungsphase. Die Ionenstrahltherapie bietet den Vorteil einer sehr konformalen Behandlung des Tumorvolumens durch die endliche Reichweite der Strahlen und ein ausgeprägtes Dosismaximum kurz vor dem Ende des Strahlpfades. Da eine Therapie in der Regel über bis zu 30 Sitzungen an verschiedenen Tagen durchgeführt wird und der Strahlweg stark von dem durchdrungenen Gewebe beeinflusst wird, sind Verfahren für eine in vivo Verifikation der Strahlapplikation wünschenswert. Eine dieser Methoden ist die Partikeltherapie–Positronen-Emissions-Tomografie (PT-PET). Sie beruht auf der Messung der vom Therapiestrahl erzeugten β+-Aktivitätsverteilung. Da eine direkte Berechnung der Dosis aus der Aktivität in lebendem Gewebe nicht möglich ist, wird die gemessene Aktivitätsverteilung mit einer berechneten Vorhersage verglichen und anschließend entschieden, ob die nächste Therapiesitzung wie geplant erfolgen kann oder Anpassungen notwendig sind. Die vorliegende Arbeit beschäftigt sich mit drei Themen aus dem Bereich der Datenverarbeitung für die PT-PET. Im ersten Teil wird ein Algorithmus zur Bestimmung von Reichweitendifferenzen aus zwei β+- Aktivitätsverteilungen adaptiert und evaluiert. Dies geschieht zunächst anhand einer Simulationsstudie mit realen Patientendaten. Ein Ansatz für eine automatisierte Analyse der Daten lieferte keine zufriedenstellenden Ergebnisse. Daher wird ein Software-Prototyp für eine semiautomatische, assistierte Datenanalyse entwickelt. Die Evaluierung erfolgt durch Experimente mit Phantomen am 12C-Strahl. Die erzeugte Aktivitätsverteilung wird von physiologischen Prozessen im Organismus beeinflusst. Dies führt zu einer Entfernung von Emittern vom Ort ihrer Erzeugung und damit zu einer Verringerung der diagnostischen Wertigkeit der erfassten Verteilung. Zur Quantifizierung dieses als Washout bezeichneten Effektes existiert ein am Tierexperiment gewonnenes Modell. Dieses Modell wird im zweiten Teil der Arbeit auf reale Patientendaten angewendet. Es konnte gezeigt werden, dass das Modell grundsätzlich anwendbar ist und für die betrachtete Tumorlokalisation Schädelbasis ein Washout mit einer Halbwertszeit von (155,7±4,6) s existiert. Die Berechnung der Vorhersage der β+-Aktivitätsverteilung kann durch übliche Monte-Carlo-Verfahren erfolgen. Dabei werden die Wechselwirkungsquerschnitte zahlreicher Reaktionskanäle benötigt. Als alternatives Verfahren wurde die Verwendung gemessener Ausbeuten (Yields) radioaktiver Nuklide in verschiedenen Referenzmaterialien vorgeschlagen. Auf Basis einer vorhandenen Datenbank dieser Yields und einer existierenden Condensed-History-Monte-Carlo-Simulation wird ein Programm zur Berechnung von Aktivitätsverteilungen auf Yieldbasis entwickelt. Mit der Methode kann die β+-Aktivitätsverteilung in Phantomen und Patienten zufriedenstellend vorhergesagt werden. Die entwickelten Verfahren sollen einen Einsatz der PT-PET im klinischen Umfeld erleichtern und damit einen breiten Einsatz ermöglichen, um das volle Potential der Ionenstrahltherapie nutzbar zu machen.
7

Design study of a Compton camera for prompts-gamma imaging during ion beam therapy

Richard, Marie-Hélène 04 September 2012 (has links) (PDF)
Ion beam therapy is an innovative radiotherapy technique using mainly carbon ion and proton irradiations. Its aim is to improve the current treatment modalities. Because of the sharpness of the dose distributions, a control of the dose if possible in real time is highly desirable. A possibility is to detect the prompt gamma rays emitted subsequently to the nuclear fragmentations occurring during the treatment of the patient. In a first time two different Compton cameras (double and single scattering) have been optimised by means of Monte Carlo simulations. The response of the camera to a photon point source with a realistic energy spectrum was studied. Then, the response of the camera to the irradiation of a water phantom by a proton beam was simulated. It was first compared with measurement performed with small-size detectors. Then, using the previous measurements, we evaluated the counting rates expected in clinical conditions. In the current set-up of the camera, these counting rates are pretty high. Pile up and random coincidences will be problematic. Finally we demonstrate that the detection system is capable to detect a longitudinal shift in the Bragg peak of +or- 5 mm, even with the current reconstruction algorithm.
8

Ein neues Konzept zur Modellierung der Positronenemitter-Produktion bei der Partikeltherapie

Priegnitz, Marlen 08 May 2013 (has links) (PDF)
Eine der drei Säulen der Krebsbehandlung ist die Strahlentherapie. Einer der neuesten Ansätze hierbei ist die Bestrahlung mit Ionen, zurzeit insbesondere Protonen und Kohlenstoffionen. Diese Hochpräzisionstherapie erfordert ein hohes Maß an Kontrolle, da die applizierte Dosisverteilung sehr empfindlich von Dichteveränderungen im durchstrahlten Gewebe abhängt. Das bisher einzige klinisch eingesetzte Verfahren zur in vivo Überwachung der Dosisapplikation bei Ionenbestrahlungen ist die Positronen-Emissions-Tomographie (PET). Sie ermöglicht eine Verifikation der Teilchenreichweite sowie der Lage des Bestrahlungsfeldes. Die mit der PET-Methode gemessene Aktivitätsverteilung lässt sich jedoch nicht direkt mit der geplanten Dosisverteilung vergleichen. Daher ist eine Vorherberechnung der erwarteten Aktivitätsverteilung auf der Grundlage des Bestrahlungsplanes notwendig, welche dann mit der Messung verglichen wird und eine qualitative Beurteilung der Bestrahlung ermöglicht. Die Vorherberechnung der erwarteten Aktivitätsverteilung erfordert bislang die Kenntnis einer Vielzahl von Wirkungsquerschnitten. Nur für wenige dieser Wirkungsquerschnitte liegen jedoch Messdaten im benötigten Energiebereich und mit ausreichender Genauigkeit vor. Daher verwenden viele Monte-Carlo-Simulationen intrinsische Kernmodelle oder semi-empirische Modellierungen, die häufig eine unzureichende Genauigkeit aufweisen. In Fachkreisen ist bisher noch nicht geklärt, welches die optimale Ionensorte für die Tumortherapie ist. Insbesondere Lithiumionen weisen aufgrund ihrer physikalischen und radiobiologischen Eigenschaften ein großes Potenzial auf. Auch für Bestrahlungen mit diesen Ionen ist ein PET-Monitoring der Therapie erstrebenswert. In der vorliegenden Arbeit wird zunächst die Anwendbarkeit der Reichweite-Verifikation mittels PET bei Bestrahlung mit Lithiumionen gezeigt. Des Weiteren wird ein Konzept zur Modellierung der Positronenemitter-Verteilung ohne Kenntnis der Wirkungsquerschnitte entwickelt. Diese Vorhersage beruht auf in Referenzmaterialien (Wasser, Graphit und Polyethylen) gemessenen tiefenabhängigen Positronenemitter-Yields, mit welchen durch geeignete Linearkombination die Verteilung der Positronenemitter in beliebigen Materialien bekannter Stöchiometrie vorausberechnet werden kann. Die Anwendbarkeit des Yield-Konzeptes wird gezeigt für Lithium- und Kohlenstoffbestrahlungen homogener Polymethylmethacrylat (PMMA) Targets sowie verschiedener inhomogener Targets.
9

Characterization of the GATE Monte Carlo platform for non-isocentric treatments and patient specific treatment plan verification at MedAustron - Vienna - Austria / Caractérisation de la plate-forme GATE Monte Carlo pour les traitements non isocentriques et vérification du plan de traitement spécifique au patient chez MedAustron - Vienna - Austria

Elia, Alessio 08 January 2019 (has links)
L'objectif de cette thèse est de développer et de valider une méthode de calcul de dose indépendante afin de soutenir le travail de mise en service intense d'une installation de traitement par faisceaux d'ions légers (LIBT) et de valider le calcul de dose du système de planification de traitement (SP). Le travail porte sur les traitements de protonthérapie et est organisé en collaboration entre le laboratoire CREATIS (Lyon, France) et le centre de thérapie ionique MedAustron - Vienna - Austria (Wiener Neustadt, Autriche). Chez MedAustron - Vienna - Austria, afin d’exploiter une pénombre latérale aiguë du faisceau de protons et d’améliorer la précision des algorithmes de calcul de la dose TPS, l’intervalle entre la fenêtre de la tête de traitement et le patient est réduit en déplaçant le patient vers la tête de traitement. Par conséquent, les traitements non isocentriques doivent être pris en compte avec précision lors de la modélisation ainsi que lors de la phase de validation, car l'éloignement de la cible de l'isocentre de la pièce peut réduire la précision du traitement. Dans cette étude, la paramétrisation du faisceau de crayons à protons suit les recommandations de Grevillot et al. (2011), mais comprenant une description complète de la buse. Un soin particulier est apporté à la modélisation des propriétés du faisceau de crayon dans des conditions non isocentriques, y compris l'utilisation d'un Range Shifter (RaShi). La caractérisation du faisceau de crayon est basée uniquement sur les profils de fluence mesurés dans le profil de dose d’air et de profondeur acquis dans l’eau. De plus, le modèle présenté est calibré en dose absolue sur la base d'un nouveau formalisme produit-zone-dose présenté dans Palmans et Vatnitsky (2016). Finalement, une validation détaillée est effectuée dans l'eau, pour les distributions de doses tridimensionnelles de forme régulière. Plusieurs paramètres couramment exploités en dosimétrie des protons, tels que la distance parcourue, la pénombre distale, la modulation, la taille des champs et la pénombre latérale pour la dosimétrie protonique sont évalués à des fins de validation. Le modèle optique à faisceau de crayon a atteint une précision de l'exigence clinique de 1 mm / 10% et il n'est pas affecté par la complexité des traitements non isocentriques ni par l'utilisation d'un RaShi. Les plages sont reproduites entre 0,2 et 0,35 mm (déviation maximale) sans et avec le décaleur de plage, respectivement. La différence de dose dans les conditions de référence est de 0,5%. La validation de l'administration de la dose en 3D dans l'eau était à 1,2% maximum. La concordance des paramètres distaux et longitudinaux est généralement meilleure que 1 mm. Les résultats obtenus serviront de référence pour la future mise en œuvre clinique du système de calcul de dose indépendant MedAustron - Vienna - Austria. / The goal of this PhD is to develop and validate an independent dose calculation method in order to support the intense commissioning work of a Light Ion Beam Therapy (LIBT) facility, and to validate the Treatment Planning System (TPS) dose calculation. The work focuses on proton therapy treatments and is held as a collaboration between the CREATIS laboratory (Lyon, France) and the MedAustron - Vienna - Austria Ion Therapy Center (Wiener Neustadt, Austria). At MedAustron - Vienna - Austria, in order to exploit a sharp lateral penumbra for the proton beam as well as to improve the accuracy of the TPS dose calculation algorithms, the air gap between the treatment head window and the patient is reduced by moving the patient towards the treatment head. Therefore, non-isocentric treatments have to be accurately taken into consideration during modeling as well as validation phase as moving the target away from the room isocenter may lead to reduced treatment accuracy. In this study, the parametrization of the proton pencil beam follows the recommendations provided in Grevillot et al. (2011), but including a full nozzle description. Special care is taken to model the pencil beam properties in non-isocentric conditions, including the use of a Range Shifter (RaShi). The characterization of the pencil beam is based solely on fluence profiles measured in air and depth dose profile acquired in water. In addition, the presented model is calibrated in absolute dose based on a newly formalism in dose-area-product presented in Palmans and Vatnitsky (2016). Eventually, a detailed validation is performed in water, for three-dimensional regular-shaped dose distributions. Several parameters commonly exploited in proton dosimetry such as range, distal penumbra, modulation, field sizes and lateral penumbra for proton dosimetry are evaluated for validation purposes. The pencil beam optics model reached an accuracy within the clinical requirement of 1mm/10% and it is not affected by the complexity of non-isocentric treatments and the use of a RaShi. Ranges are reproduced within 0.2 and 0.35 mm (max deviation) without and with range shifter, respectively. The dose difference in reference conditions is within 0.5%. The 3D dose delivery validation in water was within 1.2% at maximum. The agreement of distal and longitudinal parameters is mostly better than 1 mm. The obtained results will be used as a reference for the future clinical implementation of the MedAustron - Vienna - Austria independent dose calculation system. As an example of the potential clinical outcome of the presented work, the patient specific quality assurance measurements performed in water have been successfully reproduced within the clinical requirement of 5% accuracy for a few patients.
10

Ein neues Konzept zur Modellierung der Positronenemitter-Produktion bei der Partikeltherapie

Priegnitz, Marlen January 2012 (has links)
Eine der drei Säulen der Krebsbehandlung ist die Strahlentherapie. Einer der neuesten Ansätze hierbei ist die Bestrahlung mit Ionen, zurzeit insbesondere Protonen und Kohlenstoffionen. Diese Hochpräzisionstherapie erfordert ein hohes Maß an Kontrolle, da die applizierte Dosisverteilung sehr empfindlich von Dichteveränderungen im durchstrahlten Gewebe abhängt. Das bisher einzige klinisch eingesetzte Verfahren zur in vivo Überwachung der Dosisapplikation bei Ionenbestrahlungen ist die Positronen-Emissions-Tomographie (PET). Sie ermöglicht eine Verifikation der Teilchenreichweite sowie der Lage des Bestrahlungsfeldes. Die mit der PET-Methode gemessene Aktivitätsverteilung lässt sich jedoch nicht direkt mit der geplanten Dosisverteilung vergleichen. Daher ist eine Vorherberechnung der erwarteten Aktivitätsverteilung auf der Grundlage des Bestrahlungsplanes notwendig, welche dann mit der Messung verglichen wird und eine qualitative Beurteilung der Bestrahlung ermöglicht. Die Vorherberechnung der erwarteten Aktivitätsverteilung erfordert bislang die Kenntnis einer Vielzahl von Wirkungsquerschnitten. Nur für wenige dieser Wirkungsquerschnitte liegen jedoch Messdaten im benötigten Energiebereich und mit ausreichender Genauigkeit vor. Daher verwenden viele Monte-Carlo-Simulationen intrinsische Kernmodelle oder semi-empirische Modellierungen, die häufig eine unzureichende Genauigkeit aufweisen. In Fachkreisen ist bisher noch nicht geklärt, welches die optimale Ionensorte für die Tumortherapie ist. Insbesondere Lithiumionen weisen aufgrund ihrer physikalischen und radiobiologischen Eigenschaften ein großes Potenzial auf. Auch für Bestrahlungen mit diesen Ionen ist ein PET-Monitoring der Therapie erstrebenswert. In der vorliegenden Arbeit wird zunächst die Anwendbarkeit der Reichweite-Verifikation mittels PET bei Bestrahlung mit Lithiumionen gezeigt. Des Weiteren wird ein Konzept zur Modellierung der Positronenemitter-Verteilung ohne Kenntnis der Wirkungsquerschnitte entwickelt. Diese Vorhersage beruht auf in Referenzmaterialien (Wasser, Graphit und Polyethylen) gemessenen tiefenabhängigen Positronenemitter-Yields, mit welchen durch geeignete Linearkombination die Verteilung der Positronenemitter in beliebigen Materialien bekannter Stöchiometrie vorausberechnet werden kann. Die Anwendbarkeit des Yield-Konzeptes wird gezeigt für Lithium- und Kohlenstoffbestrahlungen homogener Polymethylmethacrylat (PMMA) Targets sowie verschiedener inhomogener Targets.

Page generated in 0.103 seconds