• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 206
  • 67
  • 16
  • 8
  • 3
  • 1
  • Tagged with
  • 329
  • 246
  • 181
  • 143
  • 137
  • 117
  • 99
  • 95
  • 82
  • 55
  • 51
  • 40
  • 38
  • 38
  • 36
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Estudo in vitro do efeito antibacteriano de cimentos de ionômero de vidro incorporados com diacetato de clorexidina / In vitro study of the antimicrobial effect of glass ionomer cements incorporated with chlorhexidine diacetate

Renato Mayhé 19 February 2014 (has links)
O objetivo deste trabalho foi o de avaliar in vitro o efeito da ação antibacteriana de cimentos de ionômero de vidro (CIVs) convencionais incorporados com diacetato de clorexidina (DCHX) sobre o Streptococcus mutans. Foram testados os CIVs Maxxion R e Vitro Fil R com a incorporação dos percentuais de 0,5%, 1% e 2% de DCHX através de difusão em ágar e pela exaustão do DCHX por até 40 dias, a fim de observar a longevidade de sua ação inibitória. Foi também avaliado o efeito do fluoreto de sódio na ação antibacteriana do DCHX. Para determinar a diferença entre a média dos halos de inibição Os resultados foram analisados por análise de variância e pelo teste Student-Newman-Keuls (SNK). Todos os corpos de prova com DCHX apresentaram halo para os CIVs variando de 2,29mm a 6,82mm para o Maxxion R e de 1,73mm a 8,97mm para o Vitro Fil R. A capacidade de inibição foi proporcional à concentração de DCHX. Através do teste SNK apenas os grupos Vitro Fil R 0,5% e1% não variaram significativamente entre si. O 15o dia foi o de maior atividade antibacteriana para ambos os CIVs. Os grupos Maxxion R 1% e 2% foram os que menos apresentaram diferenças ao longo do tempo. Não houve crescimento de S mutans para os períodos de 7 e 15 dias de exaustão, sendo verificado o crescimento de colônias apenas na superfície do meio após o período de 96hs de incubação. Não foi observado efeito antagônico na capacidade antibacteriana do DCHX na presença de fluoreto de sódio. A incorporação de DCHX aos CIVs Maxxion R e Vitro Fil R, nas concentrações testadas e por um período de até 40 dias, apresentam resultados positivos no controle bacteriano de S mutans. Dentro das limitações deste estudo é lícito concluir que: efeito da inibição ao S mutans é dependente da concentração do DCHX; o fluoreto por si só não é capaz de inibir o crescimento de S mutans; a associação do DCHX com os CIVs não alterou a capacidade da ação antibacteriana da CHX; a ação antibacteriana da CHX incorporada aos CIVs se mantém eficaz por 15 dias, independente do CIV testado. / The purpose of this study was to evaluate (the in vitro the effect) of antibacterial action of conventional glass ionomer cements (GICs glass ionomer cements) incorporated with chlorhexidine diacetate (DCHX) on Streptococcus mutans. We tested the GICs Maxxion Vitro Fil R & R with the incorporation of the percentage of 0.5%, 1% and 2% DCHX by agar diffusion and the depletion of DCHX by up to 15 days to observe the longevity of its inhibitory action. It was also evaluated the effect of sodium fluoride on the antibacterial action of DCHX. To determine the difference between the mean of the inhibition zones, the results were analyzed by analysis of variance and the Student-Newman-Keuls test (SNK). All specimens presented with DCHX halo for GICs ranging from 2.29 mm to 6.82 mm for Maxxion R and 1.73 mm to 8.97 mm for the FIL Vitro R. The inhibition capacity were proportional to the concentration of DCHX. Through the SNK test only groups Vitro Fil R 0.5% e1% did not vary significantly. The 15th day was the one with highest antibacterial activity for both GICs. The R Maxxion 1% and 2% were the groups with less differences over time. No growth was observed of S. mutans for periods of 7 and 15 days of exhaustion, with observed growth of colonies only on the surface of the culture media after 96 hours of incubation period. No antagonistic effect was observed in the ability of the antibacterial DCHX in the presence of sodium fluoride. Incorporating DCHX GICs Maxxion Vitro Fil R & R, in tested concentrations and for a period up to 40 days showed a positive bacterial control of S. mutans. Despite the limitations of this study, we may conclude that: inhibition effect of S. mutans is dependent on the concentration of DCHX; fluoride alone is not able to inhibit growth of S. mutans; the association of DCHX with VSDs did not alter the capacity of the antibacterial action of CHX and the antibacterial action of CHX incorporated into GICs remains effective for 15 days, regardless of the GIC tested.
102

Efeito do reforço estrutural em cimentos de ionômero de vidro com fibras de vidro em restaurações classe II de molares decíduos: estudo in vitro / Effect of structural reinforcement in glass ionomer restorative material with glass fibers in class II restorations in deciduous molars: study in vitro

Gisele Schuback Julião 23 February 2010 (has links)
Os objetivos deste estudo foram medir o efeito do reforço estrutural com a adição de fibras de vidro, na resistência ao teste de tração diametral e no selamento marginal de restaurações classe II com cimento de ionômero de vidro em molares decíduos. Fibras de vidro foram incorporadas ao pó do cimento de ionômero de vidro (CIV) na concentração de 40%. As fibras usadas foram do tipo E com comprimentos que variavam de 50m a 210m. A propriedade mecânica foi verificada através do teste de tração diametral, após 15 minutos, 24 horas e 15 dias de estocagem em água. Corpos de prova foram preparados com as dimensões de 4x8 mm para cada intervalo de tempo de acordo com as normas do fabricante e padrões internacionais. Para o teste de microinfiltração foram usados segundos molares decíduos hígidos, onde foram preparadas cavidades classe II padronizadas em dois grupos: a) controle com CIV Ketac Molar Easymix (3M/ESPE); e b) teste Ketac Molar Easymix (3M/ESPE); reforçado com fibras. Estes dentes foram restaurados e deixados em água por 24h e, a seguir, imersos em solução de nitrato de prata a 50% pelo mesmo período. Para que houvesse a precipitação de sais de prata os dentes foram colocados em solução reveladora de radiografias por 15 minutos. Para analisar a microinfiltração os espécimes foram seccionados na direção mesio-distal obtendo duas amostras de observação para cada cavidade restaurada. Os resultados do teste mecânico foram analisados através dos testes de variância ANOVA e de múltiplas variáveis de Tukey. Os resultados da microinfiltração foram analisados através do teste de MANN-WHITNEY. Com a metodologia empregada foi possível concluir que houve aumento dos valores de tração diametral no CIV com a adição de fibras de vidro. Para os intervalos de 24 horas e 15 dias, o CIV reforçado com fibras apresentou valores de tração diametral superiores àqueles do CIV não reforçado, havendo diferença significativa estatística (p<0,05) para os intervalos testados. No teste de microinfiltração os grupos mostraram valores semelhantes de infiltração marginal. A adição das fibras de vidro tipo E aumentou a resistência à tração diametral do CIV testado em relação ao grupo controle e as fibras de vidro não alteraram a adesão do cimento reforçado. / The aim of this study was to evaluate the strengthening effect of glass fibers when added to glass ionomer restorative material and evaluate the microleakage in class II glass ionomer cement (GIC) restorations in deciduous molars. Glass fibers were incorporated into glass ionomer powder in 40 mass%. The glass fiber used was a typical glass fiber (type E), it had between 50m and 210m length. The mechanical properties tested were diametral tensile strength after 15 minutes, 24 hours and 15 days of storage in water. Specimens of set cement (4X8mm) were prepared for measuring of each time storage. For microleakage test were selected deciduous molars with standard class II cavities restored in two goups: a) control group with GIC Ketac Molar Easymix (3M/ESPE); e b) experimental group GIC Ketac Molar Easymix (3M/ESPE) with glass fiber. After past twenty four hours immersing water, the restored teeth was immersed in silver nitrate 50% solution for similar period, and in a radiograph solution (hydroquinone Kodak) for fifteen minutes. The teeth was sectioned at the center of the restorations, and observed in stereoscope (40X). The microleakage was evaluated in scores related with the silver nitrate penetration grade at adhesive interface. The mechanical properties measurements were statistically analyzed using ANOVA followed by Tukey test and the microleakage measurement were statistically analyzed using MANN-WHITNEY test. The results showed increased diametral tensile strength by the addition of glass ionomer restorative material for 24 hours and 15 days. On the microleakage test both group were similar. It was concluded that GIC can be reinforced by addition of short glass fibers and this glass fibers dont interfere in adhesion to tooth structure.
103

Efeito da incorporação do trimetafosfato de sódio microparticulado e nanoparticulado ao cimento de ionômero de vidro nas propriedades físico-mecânicas e na desmineralização do esmalte

Abreu, Valéria Marisel de [UNESP] 28 August 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:30:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-08-28. Added 1 bitstream(s) on 2016-02-05T18:34:20Z : No. of bitstreams: 1 000857869.pdf: 2789826 bytes, checksum: cecfa33b798ebbee35330f861246deea (MD5) / O objetivo do presente estudo foi avaliar o efeito da incorporação do trimetafosfato de sódio (TMP) microparticulado (m) e nanoparticulado (n) ao cimento de ionômero de vidro (CIV) nas propriedades físico-mecânicas e na desmineralização do esmalte. Foram confeccionados corpos-de-prova (n=54) para cada grupo experimental: CIV sem TMP (CIV), CIV com TMPm 3,5%, 7% e 14% e CIV com TMPn 3,5%, 7% e 14%. Seis corposde- prova foram utilizados na determinação da liberação de fluoreto (F) e TMP em soluções de desmineralização e de remineralização durante 15 dias. As propriedades físico-mecânicas avaliadas 24 horas e 7 dias após a confecção foram: resistência à compressão (n=12), resistência à tração diametral (n=12), dureza de superfície do material (n=6) e grau de conversão de monômeros (n=6). Para o estudo da desmineralização do esmalte, corpos-de-prova (n=12) foram adaptados a blocos de esmalte selecionados pelo teste de dureza de superfície inicial (DS1) e submetidos às ciclagens de pH. A seguir, determinou-se a dureza de superfície final (DS2), em secção longitudinal (DSL) e a concentração de F no esmalte. Testes paramétricos e não paramétricos foram realizados, após a verificação da homocedasticidade dos dados (p<0,05). A adição de 14% de TMP levou a maior média de liberação de F (p<0,05) e os demais grupos foram similares ao CIV (p>0,05). Maior liberação de TMP foi observada com 14% microparticulado (p<0,05). A incorporação do TMP ao CIV promoveu uma redução média nas propriedades mecânicas de 21% (tração), 10% (compressão) e 18% (dureza), após 24 horas e em 18%, 23% e 12%, após 7 dias. O grau de conversão foi menor com adição de 14% TMP quando comparado ao CIV após 24 horas (p<0,05); no tempo de 7 dias não houve diferença entre os grupos (p>0,05). A adição de 7% e 14% de... / The aim of this study was to evaluate the effect of addition of sodium trimetaphosphate (TMP) microparticle (m) and nanoparticle (n) to the glass ionomer cement (GIC) on the physico-mechanical properties and demineralization of the enamel. Specimens (n=54) were fabricated from each experimental group: GIC without TMP (GIC), GIC with 3.5%, 7% and 14% TMPm and GIC with 3.5%, 7% and 14% TMPn. To determine the release of fluoride (F) and TMP it was used six specimens immersed into a demineralization and remineralization solution during 15 days. The physico-mechanical properties evaluated 24 hours and 7 days after fabrication were: compressive strength (n=12), diametral tensile strength (n=12), surface hardness of material (n=6) and the degree of conversion of monomers (n=6). For the study of enamel demineralization, specimens (n=12) were attached to enamel blocks selected by the initial surface hardness test (SH1) and submitted to the pH-cycling. Following, final surface (SH2) and cross-sectional (CSH) hardness, as well as enamel F concentration were determined. Parametric and non-parametric tests were performed after checking the data homoscedasticity (p<0.05). The addition of 14% TMP led to higher mean release of F (p<0.05) and the other groups were similar to the GIC (p>0.05). The release of TMP was higher with 14% microparticulate (p<0.05). The addition of TMP at GIC promoted an average reduction of mechanical properties of 21% (tensile), 10% (compressive) and 18% (hardness) after 24 hours and 18%, 23% and 12% after 7 days. The degree of conversion was lower with addition of 14% TMP compared to the GIC after 24 hours (p<0.05); at 7 days there was no difference between groups (p>0.05). Addition of 7% and 14% TMP reduced mineral loss and increased enamel F concentration when compared...
104

Efeito da ciclagem de ph erosiva nas propriedades mecânicas da dentina utilizando diferentes materiais restauradores

Guedes, Ana Paula Albuquerque [UNESP] 26 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-26Bitstream added on 2014-06-13T20:41:41Z : No. of bitstreams: 1 000737081.pdf: 1574523 bytes, checksum: 5bd18c418b9c0819dc40248db7d21062 (MD5) / O objetivo deste estudo in vitro foi avaliar o efeito da ciclagem de pH erosiva com soluções que simulam a erosão dental, provenientes de fatores extrínsecos ou intrínsecos, na dureza e módulo de elasticidade da dentina restaurada com materiais restauradores contendo fluoretos. Quarenta e cinco blocos de dentina medindo 6 x 6 mm foram restaurados com cinco materiais restauradores: sistema adesivo de condicionamento total Adper Single Bond 2 + resina composta Filtek Z250; sistema adesivo autocondicionante One Up Bond F + resina composta Filtek Z250; sistema adesivo autocondicionante Clearfil SE Protect + resina composta Filtek Z250; cimento de ionômero de vidro convencional Riva Self Cure; cimento de ionômero de vidro resinoso Riva Light Cure. Mensurações da dureza Martens e módulo de elasticidade da dentina subjacente à interface de união (10μm, 30μm, 50μm e 70μm) foram realizadas em ultramicrodurômetro digital antes e após a imersão em soluções de água deionizada, ácido cítrico ou ácido clorídrico. Após a ciclagem, os valores de dureza da dentina diminuíram para todos os materiais. Para a dentina restaurada com Adper Single Bond 2, os menores valores foram encontrados próximo a camada híbrida (10 μm) enquanto que para a dentina restaurada com os sistemas adesivos autocondicionantes (Clearfil SE Protect e One Up Bond F), esses valores foram mantidos em todas as distâncias avaliadas. Para os materiais Riva Self Cure e Riva Light Cure somente nas leituras iniciais a distância foi determinante na dureza, uma vez que quanto maior a distância da interface de união, maiores eram os valores encontrados. Com relação ao módulo de elasticidade, para a dentina restaurada com Adper Single Bond 2, não houve diferença significante em todas as distâncias avaliadas. Já na dentina restaurada com os sistemas adesivos autocondicionantes... / The aim of this study was to evaluate the effect of erosive pH cycling with solutions that simulate dental erosion in the hardness and elastic modulus of dentin restored with fluoride-releasing restorative materials. Forty five bovine dentine slabs (6,0 mm x 6,0 mm) were restored with 5 restorative materials: Adper Single Bond 2 total-etch adhesive system + Filtek Z250 composite resin; One Up Bond F self-etching adhesive system + Filtek Z250 composite resin; Clearfil SE Protect self-etching adhesive system + Filtek Z250 composite resin; Riva Self Cure conventional glass ionomer cement and Riva Light Cure light curing glass ionomer cement. The values of hardness and elastic modulus of dentin (10μm, 30μm, 50μm e 70μm) were evaluated in digital ultramicrohardner tester before and after immersion in solutions of deionized water, citric acid and hydrochloric acid. After cycling, the hardness of dentin decreased for all materials. For dentin restored with Adper Single Bond 2, the lowest values were found close to hybrid layer (10 μm), while for the dentin restored with One Up Bond F and Clearfil SE Protect, the values remained unaltered in all the evaluated distances. For dentin restored with Riva Self Cure and Riva Light Cure only in the initial measurements, the distance had a significant effect in the hardness values, since the greater the distance to the bonding interface, higher values of hardness were found. For the elastic modulus analysis, dentin restored with Adper Single Bond 2 showed no significant difference when distances from bonding interface were compared. Dentin restored with self-etching adhesive system (One Up Bond F and Clearfil SE Protect) and glass ionomer cements (Riva Self Cure and Riva Light Cure) showed a reduction in the elastic modulus values from the bonding interface, but after 30 μm the difference was not significant.
105

Avaliação da reação periodontal na técnica de colagem extra-alveolar de fraturas radiculares verticais simuladas: estudo histológico

González Hernández, Pedro Antonio [UNESP] 04 April 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-04-04Bitstream added on 2014-06-13T20:01:54Z : No. of bitstreams: 1 gonzalezhernandez_pa_dr_arafo.pdf: 857378 bytes, checksum: dab5af974cfc68ac88fb094747086b85 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo teve como objetivo verificar a resposta histológica que ocorre no periodonto de inserção após o reimplante de dentes que foram tratados através da técnica de colagem radicular extra-alveolar. Foram selecionados 16 primeiros pré-molares maxilares e mandibulares de cães (s.r.d), divididos em dois grupos de observação: 21 dias e 90 dias. Sob anestesia geral, os dentes foram extraídos utilizando a técnica primeira de exodontia. Com auxílio de um disco de diamante de dupla face foi realizado um corte longitudinal no sentido ápico-cervical e mésio-distal, simulando uma fratura radicular longitudinal. As superfícies dentinárias e cementárias internas foram condicionadas com o primer do cimento de ionômero de vidro modificado por resinas Vitremer (3M-ESPE). A fenda resultante foi preenchida com cimento de ionômero de vidro modificado por resinas Vitremer (3M-ESPE), numa proporção pó/líquido 1:2, após foi polimerizado o material. Um corte cervical transversal foi realizado e o resultante radicular foi reimplantado. Um retalho tipo Novak-Peter garantiu o sepultamento dentário. Após 21 e 90 dias um novo retalho foi realizado para expor a superfície óssea. Realizou-se uma ostectomia com a finalidade de obter um bloco ósseo-dentário. A loja óssea residual foi protegida com o retalho tipo Novak-Peter. A peça anatômica foi processada histotécnicamente para permitir a observação dos resultados em microscopia óptica. Foram consideradas estatisticamente significativas a identificação de áreas de reabsorção radicular externa inflamatória progressiva no terço médio (aos 90 dias estas se mostravam inativas); a observação dos eventos de reabsorção óssea nos terços alveolares médio e apical (ativas aos 21 dias e inativas aos 90 dias) e a capacidade de cicatrização das fibras do ligamento periodontal, evidente aos 90 dias, principalmente nas regiões... / The aim of this study was to verify the histological reply that occurred in supporting periodontal after the reimplant of teeth that had been treated using the technique of extra-alveolar root bonding. Sixteen canine maxilar and mandibular first premolars were selected, divided into two groups of observation: 21 and 90 days. Under general anesthetic, the teeth were extracted utilising forceps technique of exodontics. With the help of doublesided diamond disk, apico-cervical and mesio-distal longitudinal-sections were performed, simulating a longitudinal root fracture. The internal dentin and cementum surfaces were treated with a glass ionomer cement primer modified with resins, Vitremer (3M-ESPE). The resultant gap was filled with glass ionomer cement modified with resins, Vitremer (3M-ESPE), in the proportion powder/liquid 1:2, after which the material was polymerize. A cervic-transversal section was made and the resulting root was reimplanted. A Novak-Peter surgical flap ensured the dental buried. After 21 and 90 days, a new flap was made to expose the bone surface. An osteotomy was undertaken with the purpose of obtaining a dental-bone tissue block. The residual bone lodge was protected with a Novak-Peter surgical flap. The specimens were processed by routine histological technique for light microscope study. Were considered statistically significant: the identification of external root progressive inflammatory resorption areas in the middle third (at 90 days these were shown to be inactive); the observation of external root progressive inflammatory resorption events in medium and apical alveolar third (active at 21 days and inactive at 90 days); and the healing capacity of the periodontal ligament fibers (evident at 90 days) principally in the cervical and medium areas...(Complete abstract, click electronic address below).
106

Análise das tensões geradas durante a contração de polimerização e aplicação de cargas em restaurações diretas de resina composta. Efeito da utilização de materiais para base ou forramento

Oliveira, Luana Cristina Araújo de [UNESP] 26 June 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-06-26Bitstream added on 2014-06-13T21:02:28Z : No. of bitstreams: 1 oliveira_lca_dr_arafo.pdf: 2273954 bytes, checksum: 3107451a04bf448e6e343be28108c606 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desta investigação científica foi analisar o efeito da presença de materiais para base ou forramento, nas tensões geradas durante a contração de polimerização e aplicação de cargas, em cavidade classe I, no segundo pré-molar superior. Foram avaliadas quatro técnicas restauradoras: 1) Resina composta Z250(3M ESPE) controle, 2) Resina composta Z250(3M ESPE) + forramento com resina de baixa viscosidade FiltekFlow(3M ESPE), 3) Resina composta Z250(3M ESPE) + Forramento com ionômero de vidro modificado por resina Vitrebond(3M ESPE) e 4) Resina composta Z250(3M ESPE) + base com ionômero de vidro modificado por resina Vitrebond(3M ESPE). O estudo transcorreu em três fases: 1)Fotoelasticidade, 2)Tensilometria e 3)Elementos Finitos. 1ª Fase (Fotoelasticidade) - Nesta etapa foram avaliadas as tensões geradas durante a contração de polimerização na cavidade confeccionada em modelo fotoelástico, restaurada com as técnicas descritas acima, nomeadas F1, F2, F3 e F4 respectivamente e determinada a Tensão Cisalhante Máxima(tmáx ) na interface adesiva e realizados os Testes ANOVA e Tukey (p=0,05). 2ª Fase (Tensilometria) - Nesta etapa foram avaliadas as tensões geradas durante a contração de polimerização de cada material, assim agrupados: T1 - resina composta, T2 - resina de baixa viscosidade e T3 - Ionômero de vidro modificado por resina, os quais foram inseridos entre duas bases cilíndricas de dentina bovina (diâmetro 4,0 mm) com espessura de 2,0mm, sendo que a base superior foi conectada a uma célula de carga. Os valores de força foram registrados iniciando simultaneamente com a fotopolimerização até a completa estabilização das forças... / The aim of this study was analyze the effect of liner and base materials presence during polymerization shrinkage and load application, on cavities class I, in maxillary premolar. The following technique were assigned: 1) Composite resin Z250(3M ESPE)-control, 2) Composite resin Z250(3M ESPE) + liner with flowable FiltekFlow (3M ESPE) 3) Composite resin Z250(3M ESPE) + liner with resin-modified glass-ionomer Vitrebond(3M ESPE) e 4) Composite resin Z250(3M ESPE) + base with resin-modified glass-ionomer Vitrebond(3M ESPE). The study was divided in three phases: 1) Photoelasticity, 2) Tensilometry e 3) Finite Elements Analysis. 1ª (Photoelasticity) - In this phase was determinate polymerization shrinkage stress in photoelastic model, filled with techniques, named F1, F2, F3 e F4 respectively and Maximal Shear Stress (tmáx) was determinate along adhesive interface. Results were analyzes by Anova and Tukey Test. (p=0,05). 2ª (Tensilometry) - In this phase was determinate, polymerization shrinkage stress, for each material: T1 - composite resin, T2 - flowable resin e T3 - resin-modified glass-ionomer. Materials were inserted into 2mm space, between two dentin bovine cylindrical bases, (diameter 4,0mm), which one was connected a load cell. A curve ForceXTime, was obtained for each of samples. Results were analyzes by Anova and Tukey Test. (p=0,05). 3ª (Finite Elements Analysis) - In this phase, stresses resulting from polymerization shrinkage in combination with oclusal loading, were determinate in a 2D finite element model. The polymerization shrinkage stress was fundamented in Tensilometry and Phoelasticity results... (Complete abstract, click electronic access below)
107

Influência da adição de bioactive glass na liberação de íons do cimento de ionômero de vidro modificado por resina

Gwinner, Fernanda Pelógia Camargo [UNESP] 18 June 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-06-18Bitstream added on 2014-06-13T20:25:44Z : No. of bitstreams: 1 gwinner_fpc_dr_sjc.pdf: 429388 bytes, checksum: 8f66379f177aa22a57995cbad67ae92f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Esse estudo in vitro avaliou o efeito da adição de diferentes concentrações e composições de bioactive glass (BAG) ao cimento de ionômero de vidro modificado por resina (CIVMR) (Fuji II LC) na liberação de íons Ca2+ e PO4 3- após a imersão em simulador de fluido corpóreo (SFC), comparando com o grupo controle, sem BAG. Foram utilizados 3 tipos de BAG: BAG65 (65mol% SiO2, 31mol% CaO, 4mol% P2O5), BAG75 (75mol% SiO2, 21mol% CaO, 4mol% P2O5), BAG85 (85mol% SiO2, 11mol% CaO, 4mol% P2O5), adicionados ao CIVMR nas proporções de 25%, 35% e 50%. O BAG foi misturado ao pó do CIVMR e misturado com o líquido resinoso do CIVMR. O material foi colocado numa matriz de PVC (5mm x 1mm) e polimerizado, entre laminas de vidro, durante 40s. As amostras foram armazenadas a 37°C, com 100% de umidade, durante 24h. Após esse período as amostras foram trituradas por meio de gral e pistilo e peneiradas para a obtenção de partículas menores que 90μm. A liberação dos íons Ca2+ e PO4 3- foi mensurada após 15min, 30min, 1h, 3h, 6h e 24h de imersão de 20mg de cada material em SFC, com 5 réplicas para cada condição experimental. Para a análise estatística, foi utilizada a área sob a curva (PPM x tempo). Os dados foram submetidos à ANOVA e testes de Dunnet e Tukey (!= 0,05). Os grupos contendo BAG65 liberaram significantemente mais Ca2+ não havendo diferença entre as diferentes concentrações de BAG adicionado. Os grupos contendo BAG75 e BAG85 apresentaram resultados semelhantes, sendo que aqueles com 25% de BAG foram os que apresentaram menores valores de liberação de Ca2+ após 24h de imersão. Com relação a liberação de íons PO4 3-, os grupos contendo BAG65 apresentaram maiores valores de área... / Bioactive restorative materials may stimulate the repair of tooth structure though the release of remineralization-aiding components including calcium and phosphate. The objective of this study was to measure the ion release from resin-modified bioactive glass ionomer cement (RMBGIC) containing various formulations of bioactive glass (BAG). Three types of BAG: BAG65 (65 mol% SiO2, 31 mol% CaO, 4 mol% P2O5), BAG75 (75 mol% SiO2, 21 mol% CaO, 4 mol% P2O5), BAG85 (85 mol% SiO2, 11 mol% CaO, 4 mol% P2O5) were prepared using sol-gel method, grounded, micronized, and mixed with GIC powder (Fuji II LC, GC) in the following proportions: 1:1, 1:2, 1:3. The mixed-ionomer powders were combined with standard RMGIC liquid (Fuji II LC, GC) and light cured (40 s; Ultra Lume LED, 1100 mW/cm2) in cylindrical disk molds (5 mm x 2 mm). The cured RMBGIC specimens were grounded and sieved to 100 !m and immersed (20 mg; n=5) in 3 ml of simulated body fluid (SBF), at 37°C for 1/4, 1/2, 1, 3, 6 and 24 hours with continuous agitation. Following centrifugation and decanting, the [Ca+2] and [HxPO4 3-x] in the SBF were measured using ion specific electrode and visible spectroscopy, respectively. The amount of ion release were statistically analyzed using ANOVA/Tukey ($= 0.05). The [PO4 3-] in SBF immediately increased for all RMBGICs. The ion release slowly decreased after 1 h, yet remained higher than the original SBF over the 24 h period. The [PO4 3-] in SBF for the control GIC continuously decreased. Overall, BAG65 > BAG75= BAG85 > GIC for [PO4 3-]. The [Ca2+] release increase initially for all RMBGICs, remaining with higher values than thecontrol GIC. Resin modified glass ionomer cement... (Complete abstract click electronic access below)
108

Propriedades antimicrobianas, físico-mecânicas e de liberação de fluoreto do cimento de ionômero de vidro associado ao hexametafosfato de sódio microparticulado e nanoparticulado

Hosida, Thayse Yumi [UNESP] 25 February 2015 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-25. Added 1 bitstream(s) on 2015-06-18T12:48:45Z : No. of bitstreams: 1 000830085.pdf: 704356 bytes, checksum: fbb6f56d09478a8adc55d7eb2addad71 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O objetivo do presente estudo foi avaliar as propriedades antimicrobianas, físico-mecânicas e de liberação de fluoreto do cimento de ionômero de vidro (CIV) associado ao hexametafosfato de sódio (HMP) microparticulado e nanoparticulado. Inicialmente, foram obtidas soluções de HMP nas concentrações 1, 3, 6, 9 e 12 % e a atividade antibacteriana foi avaliada contra Streptococcus mutans, Lactobacillus acidophilus e Actinomyces israelli por meio do teste de difusão em ágar. A mesma metodologia foi empregada para determinar a atividade antimicrobiana do CIV associado ao HMP nas concentrações de 6, 9 e 12 % microparticulado ou nanoparticulado. Foi determinada a liberação de fluoreto (F) e HMP em soluções de desmineralização e remineralização. Além disso, as resistências à tração diametral e compressão, dureza de superfície e grau de conversão de monômeros foram analisados. Testes paramétricos e não paramétricos foram realizados, após a verificação da homocedasticidade dos dados (p < 0,05). As soluções de 6, 9 e 12 % de HMP apresentaram melhor atividade antimicrobiana contra as bactérias testadas, sendo essas concentrações incorporadas ao CIV. Todas as concentrações de HMP associado ao CIV tiveram atividade antimicrobiana para todas as bactérias. Observou-se uma relação dose-resposta entre concentração de HMP no CIV e a atividade antimicrobiana. Com relação à liberação de F e HMP, os maiores valores ocorreram no primeiro dia em todos os grupos e as maiores médias de liberação ocorreram nos grupos contendo 9 e 12 % de HMP nanoparticulado. Entretanto, a incorporação do HMP ao CIV reduziu as propriedades físico-mecânicas quando comparado ao CIV mostrando uma relação dose-resposta. Concluiu-se que a incorporação de HMP no CIV melhora a atividade antimicrobiana e aumenta a liberação de F, porém reduz suas... / The aim of this study was to evaluate antimicrobial, physico-mechanical and fluoride release properties of the glass ionomer cement (GIC) associated with HMP microparticle and nanoparticle. Initially, solutions of HMP were obtained at concentrations of 1, 3, 6, 9 and 12 %, and the antibacterial activity was evaluated against Streptococcus mutans, Lactobacillus acidophilus and Actinomyces israelli by agar diffusion test. The same methodology was used to determine the antimicrobial activity of GIC associated with HMP at concentrations of 6, 9 and 12 % microparticle or nanoparticle. The release of F and HMP were determined in demineralization and remineralization solutions. Furthermore, the resistance to diametral tensile and compression, surface hardness and the degree of conversion of monomers were measured. Parametric and non-parametric tests were performed, after checking homocedasticity data (p < 0.05). The solutions of 6, 9 and 12 % of HMP showed better antimicrobial activity against all bacteria tested, and these concentrations incorporated into the CIV. All concentrations of HMP incorporated into the GIC had antimicrobial activity for all bacteria. There was a dose-response relationship between concentration of HMP in the GIC and antimicrobial activity. Regarding the release of F and HMP, higher values occurred on the first day in all groups and the highest levels of release occurred in groups containing 9 and 12 % of HMP nanoparticle. However the incorporation of HMP in the GIC reduced values of physical and mechanical tests when compared to the GIC, showing a dose-response relationship. It was concluded that the incorporation of HMP in GIC improves antimicrobial activity and increase the release of fluoride, but reduces its physical and mechanical properties. The reduction of particulate HMP led to better antimicrobial and fluoride release results
109

Efeito da ciclagem de ph erosiva nas propriedades mecânicas da dentina utilizando diferentes materiais restauradores /

Guedes, Ana Paula Albuquerque. January 2013 (has links)
Orientador: Paulo Henrique dos Santos / Banca: André Luiz Fraga Briso / Banca: Renato Herman Sundfeld / Banca: Cláudia Batitucci dos Santos Daroz / Banca: Anderson Catelan / Resumo: O objetivo deste estudo in vitro foi avaliar o efeito da ciclagem de pH erosiva com soluções que simulam a erosão dental, provenientes de fatores extrínsecos ou intrínsecos, na dureza e módulo de elasticidade da dentina restaurada com materiais restauradores contendo fluoretos. Quarenta e cinco blocos de dentina medindo 6 x 6 mm foram restaurados com cinco materiais restauradores: sistema adesivo de condicionamento total Adper Single Bond 2 + resina composta Filtek Z250; sistema adesivo autocondicionante One Up Bond F + resina composta Filtek Z250; sistema adesivo autocondicionante Clearfil SE Protect + resina composta Filtek Z250; cimento de ionômero de vidro convencional Riva Self Cure; cimento de ionômero de vidro resinoso Riva Light Cure. Mensurações da dureza Martens e módulo de elasticidade da dentina subjacente à interface de união (10μm, 30μm, 50μm e 70μm) foram realizadas em ultramicrodurômetro digital antes e após a imersão em soluções de água deionizada, ácido cítrico ou ácido clorídrico. Após a ciclagem, os valores de dureza da dentina diminuíram para todos os materiais. Para a dentina restaurada com Adper Single Bond 2, os menores valores foram encontrados próximo a camada híbrida (10 μm) enquanto que para a dentina restaurada com os sistemas adesivos autocondicionantes (Clearfil SE Protect e One Up Bond F), esses valores foram mantidos em todas as distâncias avaliadas. Para os materiais Riva Self Cure e Riva Light Cure somente nas leituras iniciais a distância foi determinante na dureza, uma vez que quanto maior a distância da interface de união, maiores eram os valores encontrados. Com relação ao módulo de elasticidade, para a dentina restaurada com Adper Single Bond 2, não houve diferença significante em todas as distâncias avaliadas. Já na dentina restaurada com os sistemas adesivos autocondicionantes ... / Abstract: The aim of this study was to evaluate the effect of erosive pH cycling with solutions that simulate dental erosion in the hardness and elastic modulus of dentin restored with fluoride-releasing restorative materials. Forty five bovine dentine slabs (6,0 mm x 6,0 mm) were restored with 5 restorative materials: Adper Single Bond 2 total-etch adhesive system + Filtek Z250 composite resin; One Up Bond F self-etching adhesive system + Filtek Z250 composite resin; Clearfil SE Protect self-etching adhesive system + Filtek Z250 composite resin; Riva Self Cure conventional glass ionomer cement and Riva Light Cure light curing glass ionomer cement. The values of hardness and elastic modulus of dentin (10μm, 30μm, 50μm e 70μm) were evaluated in digital ultramicrohardner tester before and after immersion in solutions of deionized water, citric acid and hydrochloric acid. After cycling, the hardness of dentin decreased for all materials. For dentin restored with Adper Single Bond 2, the lowest values were found close to hybrid layer (10 μm), while for the dentin restored with One Up Bond F and Clearfil SE Protect, the values remained unaltered in all the evaluated distances. For dentin restored with Riva Self Cure and Riva Light Cure only in the initial measurements, the distance had a significant effect in the hardness values, since the greater the distance to the bonding interface, higher values of hardness were found. For the elastic modulus analysis, dentin restored with Adper Single Bond 2 showed no significant difference when distances from bonding interface were compared. Dentin restored with self-etching adhesive system (One Up Bond F and Clearfil SE Protect) and glass ionomer cements (Riva Self Cure and Riva Light Cure) showed a reduction in the elastic modulus values from the bonding interface, but after 30 μm the difference was not significant. / Doutor
110

Avaliação de materiais restauradores ionoméricos, empregando a técnica do ART

Fernandes, Adriana Beatriz Silveira Pinto [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T20:36:13Z : No. of bitstreams: 1 fernandes_absp_me_araca.pdf: 2346845 bytes, checksum: f5101690e1608a466dec96035c51358b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação para o Desenvolvimento da UNESP (FUNDUNESP) / Este estudo teve como objetivo avaliar a interação dos materiais ionoméricos com a dentina, na remoção do tecido cariado, empregando a técnica convencional e a do ART. De um total de 109 dentes, 13 ficaram para controle, 48 foram preparados pela técnica convencional, G I, e os outros 48 pela técnica do ART, G II. Após o preparo das cavidades, os espécimes foram aleatoriamente divididos em 03 subgrupos de acordo com o material restaurador ionomérico empregado: KETAC FILL para G I 1 e G II 1, VIDRION R para G I 2 e G II 2 e FUJI II LC para G I 3 e G II 3, todos com 16 dentes em cada subgrupo. Em cada subgrupo experimental, 06 dentes foram avaliados macroscopicamente e os outros 10, microscopicamente. Para a análise macroscópica, a parte radicular de 36 espécimes restaurados e de 03 espécimes controle foi incluída em resina, e o dente cortado em fatias. Cada fatia foi analisada em lupa estereoscópica a um aumento de 60 vezes. Para a análise microscópica, os 60 dentes preparados e os outros 10 cariados foram descalcificados em solução de EDTA, desidratados e submetidos a banhos de parafina, cortados a uma espessura de 6 micrometros, corados pelo método de Brown & Brenn, e avaliados em microscopia óptica. Os resultados na macroscopia revelaram uma boa adaptação dos materiais à superfície dentinária, pós remoção do tecido cariado; sugerindo semelhança de comportamento quando considerada a técnica de remoção de dentina cariada: convencional e ART. Quando considerado os materiais ionoméricos a avaliação da interface demonstrou um melhor comportamento dos ionômeros FUJI II LC e KETAC FILL em relação ao VIDRION R. Na análise microscópica somente com o FUJI II LC foi possível observar interação do material com a estrutura dentinária, revelando ainda supremacia de comportamento quando se utilizou a técnica convencional em relação a técnica do ART. / This study evaluated the interaction between glass ionomer materials and dentine using the convencional technique and ART in the remotion of decayed tissue. One hundred and nine teeth were used, 13 as control, 48 prepared by the conventional technique (group I) and the other 48 by ART technique (group II). After preparation of the cavites, the specimens were divided in 3 subgroups according to the glass ionomer material used: KETAC FILL for groups G I 1 and G II 1, VIDRION R for groups G I 2 and G II 2 and FUJI II LC for groups G I 3 and G II 3, all with 16 teeth in each subgroup. In each experimental subgroup, 6 teeth were evaluated macroscopically and the other 10, microscopically. For the macroscopic analysis, the root of 36 restored specimens and 3 control specimens were included in resin and the tooth was divided in slices. Each slice was analyzed in a stereoscopic magnifying glass at 60 times magnifying power. For the macroscopic analysis, the 60 prepared teeth and the other 10 decayed ones were decalcified in EDTA solution, dehydrated and subjected to parafine baths, cutt with 6 μm thickness, stained by the Brown & Brenn method, and evaluated in a light microscope. The results of the macroscopic analysis showed a good adaptation of the materials to dentine surface, after remotion of decayed tissue, suggesting similarity of behavior when considering the technique of decayed dentine remotion: conventional and ART. When considering ionomer materials, the evaluation of the interface showed a better behavior of FUJI II LC and KETAC FILL in comparison to VIDRION R. In the microscopic analysis, it was possible to observe the interaction between the material and dentine structure only with FUJI II LC, showing the supremacy of behavior when using the conventional technique in comparison to ART technique.

Page generated in 0.0595 seconds