• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 206
  • 67
  • 16
  • 8
  • 3
  • 1
  • Tagged with
  • 329
  • 246
  • 181
  • 143
  • 137
  • 117
  • 99
  • 95
  • 82
  • 55
  • 51
  • 40
  • 38
  • 38
  • 36
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Supercritical fluid processing of perfluorinated sulfonated membranes /

Ocasio Velázquez, Mayra. January 2004 (has links) (PDF)
Thesis (m.S. Ch. E.)--University of Puerto Rico, Mayagüez Campus, 2004. / Tables. Printout. Includes bibliographical references (leaves 88-91.)
92

Estudo in vitro do efeito antibacteriano de cimentos de ionômero de vidro incorporados com diacetato de clorexidina / In vitro study of the antimicrobial effect of glass ionomer cements incorporated with chlorhexidine diacetate

Renato Mayhé 19 February 2014 (has links)
O objetivo deste trabalho foi o de avaliar in vitro o efeito da ação antibacteriana de cimentos de ionômero de vidro (CIVs) convencionais incorporados com diacetato de clorexidina (DCHX) sobre o Streptococcus mutans. Foram testados os CIVs Maxxion R e Vitro Fil R com a incorporação dos percentuais de 0,5%, 1% e 2% de DCHX através de difusão em ágar e pela exaustão do DCHX por até 40 dias, a fim de observar a longevidade de sua ação inibitória. Foi também avaliado o efeito do fluoreto de sódio na ação antibacteriana do DCHX. Para determinar a diferença entre a média dos halos de inibição Os resultados foram analisados por análise de variância e pelo teste Student-Newman-Keuls (SNK). Todos os corpos de prova com DCHX apresentaram halo para os CIVs variando de 2,29mm a 6,82mm para o Maxxion R e de 1,73mm a 8,97mm para o Vitro Fil R. A capacidade de inibição foi proporcional à concentração de DCHX. Através do teste SNK apenas os grupos Vitro Fil R 0,5% e1% não variaram significativamente entre si. O 15o dia foi o de maior atividade antibacteriana para ambos os CIVs. Os grupos Maxxion R 1% e 2% foram os que menos apresentaram diferenças ao longo do tempo. Não houve crescimento de S mutans para os períodos de 7 e 15 dias de exaustão, sendo verificado o crescimento de colônias apenas na superfície do meio após o período de 96hs de incubação. Não foi observado efeito antagônico na capacidade antibacteriana do DCHX na presença de fluoreto de sódio. A incorporação de DCHX aos CIVs Maxxion R e Vitro Fil R, nas concentrações testadas e por um período de até 40 dias, apresentam resultados positivos no controle bacteriano de S mutans. Dentro das limitações deste estudo é lícito concluir que: efeito da inibição ao S mutans é dependente da concentração do DCHX; o fluoreto por si só não é capaz de inibir o crescimento de S mutans; a associação do DCHX com os CIVs não alterou a capacidade da ação antibacteriana da CHX; a ação antibacteriana da CHX incorporada aos CIVs se mantém eficaz por 15 dias, independente do CIV testado. / The purpose of this study was to evaluate (the in vitro the effect) of antibacterial action of conventional glass ionomer cements (GICs glass ionomer cements) incorporated with chlorhexidine diacetate (DCHX) on Streptococcus mutans. We tested the GICs Maxxion Vitro Fil R & R with the incorporation of the percentage of 0.5%, 1% and 2% DCHX by agar diffusion and the depletion of DCHX by up to 15 days to observe the longevity of its inhibitory action. It was also evaluated the effect of sodium fluoride on the antibacterial action of DCHX. To determine the difference between the mean of the inhibition zones, the results were analyzed by analysis of variance and the Student-Newman-Keuls test (SNK). All specimens presented with DCHX halo for GICs ranging from 2.29 mm to 6.82 mm for Maxxion R and 1.73 mm to 8.97 mm for the FIL Vitro R. The inhibition capacity were proportional to the concentration of DCHX. Through the SNK test only groups Vitro Fil R 0.5% e1% did not vary significantly. The 15th day was the one with highest antibacterial activity for both GICs. The R Maxxion 1% and 2% were the groups with less differences over time. No growth was observed of S. mutans for periods of 7 and 15 days of exhaustion, with observed growth of colonies only on the surface of the culture media after 96 hours of incubation period. No antagonistic effect was observed in the ability of the antibacterial DCHX in the presence of sodium fluoride. Incorporating DCHX GICs Maxxion Vitro Fil R & R, in tested concentrations and for a period up to 40 days showed a positive bacterial control of S. mutans. Despite the limitations of this study, we may conclude that: inhibition effect of S. mutans is dependent on the concentration of DCHX; fluoride alone is not able to inhibit growth of S. mutans; the association of DCHX with VSDs did not alter the capacity of the antibacterial action of CHX and the antibacterial action of CHX incorporated into GICs remains effective for 15 days, regardless of the GIC tested.
93

Resistência de união e limite de fadiga de nichos confeccionados em resina composta e cimentos à base de ionômero de vidro

Lopes, José Fernando Scarelli [UNESP] 17 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-17Bitstream added on 2014-06-13T18:58:07Z : No. of bitstreams: 1 lopes_jfs_me_arafo.pdf: 1497511 bytes, checksum: 5cff0da20eacc454b65a7066c2aba9f6 (MD5) / O objetivo desta investigação foi determinar a resistência de união e limite de fadiga de nichos confeccionados em resina composta e ionômeros de vidro. Setenta e cinco corpos-de-prova (incisivos mandibulares humanos hígidos) com etiquetas adesivas com perfurações de 3,5mm de diâmetro foram adaptadas sobre a superfície lingual de cada dente. Esta delimitação tinha como objetivo padronizar a área da superfície de esmalte a ser condicionada e, posteriormente, mantida em contato com os materiais restauradores. Para realização dos nichos, matrizes foram realizadas para cada corpo-de-prova onde o material restaurador foi inserido. Os corpos-de-prova foram imersos em água destilada a 37ºC por um período de 30 dias. Para os ensaios de resistência à união, a máquina de testes mecânicos MTS modelo 810 foi calibrada utilizando uma velocidade de deslocamento de 0,5mm/min. Para os testes de limite de fadiga a máquina de testes foi calibrada para submeter cada corpo-de-prova a 10.000 ciclos constantes, com uma freqüência de 5 Hz, amplitude inicial de 0,5 mm e velocidade de rampa inicial de 100N/s. Os valores originais do experimento foram convertidos de N para MPa em função da área da base do nicho (circular) previamente calculada. Os corpos-de-prova após a fratura foram avaliados através de microscopia eletrônica de varredura com aumento de 500 vezes. A médias de resistência à união e limite de fadiga foram comparadas estatisticamente usando o teste de Análise de Variância a um Critério. Nos teste de cisalhamento, a resina composta Z-100 produziu maior valor de resistência de união (12,25 MPa) ao esmalte dentário que o ionômero de vidro convencional Fuji IX (7,21MPa). Não foram observadas diferenças entre os valores do material Fuji II LC (10,29MPa) e os demais materiais. Para todos os materiais, os corpos-de-prova testados por meio de ensaio dinâmico de... / The aim of this study was to determine the bond strength and fatigue limit of rest seats prepared with composite resin and glass ionomer cements. The lingual aspect of seventy-five specimens (intact human mandibular incisors) was delimited by adhesive tags with 3.5-mm diameter perforations. This delimitation aimed at standardizing the area of enamel surface to be etched and later kept in contact with the restorative materials. For preparation of the rest seats, matrixes were obtained for each specimen on which the restorative material was placed. The specimens were immersed in distilled water at 37ºC for a period of 30 days. For the bond strength assays, the mechanical assay machine MTS model 810 was calibrated at a displacement speed of 0.5mm/min. For the fatigue limit tests, the assay machine was calibrated so as to submit each specimen to 10,000 constant cycles, at a 5-Hz frequency with an initial range of 0.5mm and initial sloping speed of 100N/s. The original values of the experiment were converted from N to MPa according to the previously calculated circular area of the base of the rest seat. After fracture, the specimens were evaluated by means of scanning electron microscopy with magnification of 500x. The means of bond strength and fatigue limits were statistically compared through the one-way variance analysis. For the shear resistance test, the composite resin Z-100 yielded a higher value of bond strength (12.25 MPa) to the dental enamel than the conventional glass ionomer cement Fuji IX (7.21MPa). No differences could be found between Fuji II LC (10.29MPa) and the further materials. For all materials, the specimens submitted to dynamic fatigue assay tests yielded lower mean values than those achieved through static shear assays. Regarding the fatigue limit values, all materials presented different behaviors, being that Fuji II LC obtained the higher mean value (6.4MPa), ...(Complete abstract, click electronic access below)
94

Análise das tensões geradas durante a contração de polimerização e aplicação de cargas em restaurações diretas de resina composta. Efeito da utilização de materiais para base ou forramento /

Oliveira, Luana Cristina Araújo de. January 2004 (has links)
Resumo: O objetivo desta investigação científica foi analisar o efeito da presença de materiais para base ou forramento, nas tensões geradas durante a contração de polimerização e aplicação de cargas, em cavidade classe I, no segundo pré-molar superior. Foram avaliadas quatro técnicas restauradoras: 1) Resina composta Z250(3M ESPE) controle, 2) Resina composta Z250(3M ESPE) + forramento com resina de baixa viscosidade FiltekFlow(3M ESPE), 3) Resina composta Z250(3M ESPE) + Forramento com ionômero de vidro modificado por resina Vitrebond(3M ESPE) e 4) Resina composta Z250(3M ESPE) + base com ionômero de vidro modificado por resina Vitrebond(3M ESPE). O estudo transcorreu em três fases: 1)Fotoelasticidade, 2)Tensilometria e 3)Elementos Finitos. 1ª Fase (Fotoelasticidade) - Nesta etapa foram avaliadas as tensões geradas durante a contração de polimerização na cavidade confeccionada em modelo fotoelástico, restaurada com as técnicas descritas acima, nomeadas F1, F2, F3 e F4 respectivamente e determinada a Tensão Cisalhante Máxima(tmáx ) na interface adesiva e realizados os Testes ANOVA e Tukey (p=0,05). 2ª Fase (Tensilometria) - Nesta etapa foram avaliadas as tensões geradas durante a contração de polimerização de cada material, assim agrupados: T1 - resina composta, T2 - resina de baixa viscosidade e T3 - Ionômero de vidro modificado por resina, os quais foram inseridos entre duas bases cilíndricas de dentina bovina (diâmetro 4,0 mm) com espessura de 2,0mm, sendo que a base superior foi conectada a uma célula de carga. Os valores de força foram registrados iniciando simultaneamente com a fotopolimerização até a completa estabilização das forças... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was analyze the effect of liner and base materials presence during polymerization shrinkage and load application, on cavities class I, in maxillary premolar. The following technique were assigned: 1) Composite resin Z250(3M ESPE)-control, 2) Composite resin Z250(3M ESPE) + liner with flowable FiltekFlow (3M ESPE) 3) Composite resin Z250(3M ESPE) + liner with resin-modified glass-ionomer Vitrebond(3M ESPE) e 4) Composite resin Z250(3M ESPE) + base with resin-modified glass-ionomer Vitrebond(3M ESPE). The study was divided in three phases: 1) Photoelasticity, 2) Tensilometry e 3) Finite Elements Analysis. 1ª (Photoelasticity) - In this phase was determinate polymerization shrinkage stress in photoelastic model, filled with techniques, named F1, F2, F3 e F4 respectively and Maximal Shear Stress (tmáx) was determinate along adhesive interface. Results were analyzes by Anova and Tukey Test. (p=0,05). 2ª (Tensilometry) - In this phase was determinate, polymerization shrinkage stress, for each material: T1 - composite resin, T2 - flowable resin e T3 - resin-modified glass-ionomer. Materials were inserted into 2mm space, between two dentin bovine cylindrical bases, (diameter 4,0mm), which one was connected a load cell. A curve ForceXTime, was obtained for each of samples. Results were analyzes by Anova and Tukey Test. (p=0,05). 3ª (Finite Elements Analysis) - In this phase, stresses resulting from polymerization shrinkage in combination with oclusal loading, were determinate in a 2D finite element model. The polymerization shrinkage stress was fundamented in Tensilometry and Phoelasticity results... (Complete abstract, click electronic access below) / Orientador: Sillas Luiz Lordelo Duarte Júnior / Coorientador: Welingtom Dinelli / Banca: José Roberto Cury Saad / Banca: Osmir Batista de Oliveira Júnior / Banca: Cleudmar Amaral de Araújo / Banca: Rafael Francisco Lia Mondelli / Doutor
95

Efeito da incorporação de nanopartículas de hexametafosfato de clorexidina em propriedades de um cimento de ionômero de vidro de alta viscosidade /

Souza, Ana Carolina Becci de. January 2017 (has links)
Orientador: Elisa Maria Aparecida Giro / Resumo: Lesões de cárie secundarias nas margens das restaurações tem sido a principal razão para a sua substituição. Portanto, o desenvolvimento de materiais com propriedades antibacterianas melhoradas e duradouras é desejável. O objetivo deste estudo foi avaliar a influência da incorporação de nanopartículas de hexametafosfato de clorexidina (NPs CLX-HMP) a um cimento de ionômero de vidro (CIV) de alta viscosidade, nas suas propriedades físico-químicas, mecânica e antibacteriana. Após a síntese e caracterização, as nanopartículas foram adicionadas ao CIV nas concentrações de 1%, 2% e 5%. O CIV sem adição de nanopartículas foi utilizado como controle. Espécimes cilíndricos (3mm x 6mm) foram confeccionados com os materiais (n=12/grupo) e mantidos em água deionizada por 30 dias. A liberação de CLX foi avaliada no eluato por espectrofotometria ultravioleta e a dosagem do flúor foi feita com auxílio de um eletrodo específico, nos períodos de 1 h e 1, 7, 15 e 30 dias. No 30º dia, os espécimes receberam uma aplicação tópica de flúor gel neutro 2% e a liberação de flúor foi reavaliada por mais 30 dias. Para avaliar a atividade antibacteriana, biofilmes polimicrobianos cresceram sobre espécimes dos materiais (n=10/grupo), utilizando um modelo de aderência ativa. Em seguida, foram coletados e inoculados em meios de cultura específicos para a quantificação de microrganismos totais, bactérias acidúricas totais e estreptococos do grupo mutans. A atividade metabólica foi analisada pelo ensaio de ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Secondary caries on the margins of restorations have been the main reason for their replacement. Therefore, the development of materials with improved and long-lasting antibacterial properties is desirable. The objective of this study was to evaluate the influence of the incorporation of chlorhexidine hexametaphosphate nanoparticles (CHX-HMP NPs) to a high viscosity glass ionomer cement (GIC) in its physicochemical, mechanical and antibacterial properties. After synthesis and characterization, the nanoparticles were added to the GIC at concentrations of 0%, 1%, 2% and 5%. Cylindrical specimens (3 mm x 6 mm) made with the materials were kept in deionized water for 30 days. The CHX release was evaluated in the eluate by ultraviolet spectrophotometry and the fluoride dosage was done with the help of a specific electrode, in the periods of 1 h and 1, 7, 15 and 30 days. On the 30th day, the specimens received a topical application of neutral fluorine gel 2% and the fluoride release was reevaluated for another 30 days. To evaluate the antibacterial activity, polymicrobial biofilms grew on the specimens of the materials, using an active adherence model. The biofilms formed were collected, inoculated in specific culture media and thereafter, the quantification of total microorganisms, total acid bacteria and streptococci of mutans group was made. The metabolic activity was analyzed by the XTT assay and the biomass by violet crystal staining. Finally, it was evaluated the bond strength of the material to the sound and caries-affected dentin, after 24 h and 6 months of storage of the specimens in artificial saliva, using the microshear test. The fracture patterns were evaluated with the aid of light microscope. Adequate statistical tests were applied according to the distribution of the data and the homogeneity of variances. The level of significance was set at 5%. The synthesized nanoparticles presented ...(complete abstract electronic access below) / Doutor
96

Microdureza de cimentos de ionômeros de vidro indicados para a técnica do ART, variando-se a proteção superficial e o tempo de armazenamento /

Shintome, Luciana Keiko. January 2007 (has links)
Orientador: Rebeca Di Nicoló / Banca: Maria Beatriz Duarte Galvão / Banca: Maria Naira Pereira Friggi / Banca: Maria Amélia Máximo de Araujo / Banca: Silvio Issáo Myaki / Resumo: O objetivo deste estudo foi avaliar a microdureza de cimentos de ionômero de vidro (CIV): Vidrion R (V) .- SS White; Fuji IX (F) . GC Corp; Magic Glass ART (MG) - Vigodent; Maxxion R (MR) - FGM e ChemFlex (CF) - Dentsply, na presença ou ausência de proteção superficial, em diferentes períodos de armazenamento. Para cada CIV foram confeccionados 36 corpos-de-prova (3 mm altura X 3 mm diâmetro), divididos em 3 grupos em função da proteção superficial (sem proteção, verniz do Fuji IX ou esmalte para unha). Os espécimes foram armazenados em água destilada por 24 h, 7 e 30 dias e os testes de microdureza foram realizados nestes tempos. Os dados obtidos foram submetidos ao teste de ANOVA para medidas repetidas e teste de Tukey ('alfa'=5%), e revelaram que os valores médios de microdureza, no geral, em ordem decrescente dos CIV foram: F > CF = MR > MG > V; que a proteção superficial foi significante para o MR em 24 h sem proteção (64,2'mais ou menos'3,6a), proteção com verniz (59,6'mais ou menos'3,4b) e com esmalte (62,7'mais ou menos'2,8ab); para o F, em 7 dias, sem proteção (97,8'mais ou menos'3,7ab), proteção com verniz (95,9'mais ou menos'3,2b) e com esmalte (100,8'mais ou menos'3,4a) e em 30 dias para o F sem proteção (98,8'mais ou menos'2,6b), proteção com verniz (103,3'mais ou menos'4,4a) e com esmalte (101'mais ou menos'4,1ab) e V sem proteção (46'mais ou menos'1,3b), proteção com verniz (49,6'mais ou menos'1,7ab) com esmalte (51,1'mais ou menos'2,6a) e o aumento do tempo de armazenamento proporcionou um aumento da microdureza. Concluiu-se que os diferentes CIV, tipo de proteção e tempo de armazenamento, podem alterar os valores de microdureza...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the microhardness of glass ionomer cement (GIC): Vidrion R (V) - SS White; Fuji IX (F) - GC Corp.; Magic Glass ART (MG) - Vigodent; Maxxion R (MR) - FGM and ChemFlex (CF) - Dentsply, with or without surface protection in different storage time. Thirty six specimens for each GIC (3 mm diameter X 3 mm height) were made and these specimens were divided into three groups, according to the surface protection (without protection, varnish protection of the Fuji IX or protection with nail varnish). The samples were stored in distilled water for 24 h, 7 and 30 days and the microhardness test was carried out using a microhardner in those times. The data were submitted to repeated measures analysis of variance test and Tukey test ('alfa' =0.05) and showed that mean microhardness values, in general, of the GIC followed the decrescent order: F > CF = MR > MG > V; the surface protection was significant for MR in 24 h without protection (64.2'mais ou menos'3.6a), protection with varnish (59.6'mais ou menos'3.4b) and nail varnish (62.7'mais ou menos'2.8ab); for F in 7 days without protection (97.8'mais ou menos'3.7ab), protection with varnish (95.9'mais ou menos'3.2b) and nail varnish (100.8'mais ou menos'3.4a); for F in 30 days without protection (98.8'mais ou menos'2.6b), protection with varnish (103.3'mais ou menos'4.4a) and nail varnish (101'mais ou menos'4.1ab) and for V in 30 days without protection (46'mais ou menos'1.3b), protection with varnish (49.6'mais ou menos'1.7ab) and nail varnish (51.1'mais ou menos'2.6a) and surface microhardness generally increased with time. It was concluded that different trade mark, surface protection and storage times can influence microhardness of GIC. / Doutor
97

Compréhension par établissement de courbes d'étalonnage de la structure des membranes perfluorées sulfoniques pour pile à combustible / Understanding of the structure of perfluorinated sulfonic membranes for fuel cell

Moukheiber, Eddy 05 July 2011 (has links)
Ce travail de thèse a pour but l’étude des effets de la contamination cationique sur lamembrane électrolyte afin d’élaborer des outils de caractérisation et de diagnostic de cette pollution.Premièrement, la caractérisation physico-chimique de membranes PFSA commerciales arévélé des paramètres pertinents de structure et de propriété, qui ont été étudiés en fonction de leurdépendance à la capacité d’échange ionique (IEC).Deuxièmement, les propriétés thermiques des membranes contaminées par des cations ontrévélé des changements dépendant fortement de l’acidité de Lewis du cation (LAS). Cette tendance aété corrélée à la nature de l’interaction des différents cations avec les groupements polaires de lachaîne polymère, révélée par FTIR.Enfin, l’influence du taux de pollution sur les différents paramètres thermiques et structurauxnous a permis de révéler ceux qui sont pertinents non seulement à l’identification mais aussi à laquantification de la pollution. Une application des courbes d’étalonnage a été réalisée sur desmembranes vieillies issues de systèmes réels après fonctionnement. / The purpose of this study was to experimentally determine the effects of cationiccontamination on PEMFC ionomers in order to elaborate characterization tools and new modes forpollution diagnosis.First, a large series of techniques were used to investigate the properties of commercial PFSAmembranes. Distinctive parameters concerning structure and properties were extracted as well as theirrelationship to ion exchange capacity (IEC).Second, the thermal properties of cation-contaminated membranes revealed changes that arehighly dependent on the Lewis Acid Strength of the cation (LAS). This trend was correlated with thenature of the interaction between the cations and the polar groups of the polymer chain, revealed byFTIR spectroscopy.Finally, the influence of the pollution level on the thermal and structural parameters allowedus to reveal not only the relevant parameters to the identification but also to the quantification ofpollution. An application of the different calibration curves was performed on aged membranescoming from real operating systems.
98

Avaliação das restaurações atraumáticas em pré-escolares

Barreto, Vanessa Constant January 2007 (has links)
Proposição: o objetivo deste trabalho foi avaliar, após doze meses, qualitativamente o desempenho clínico e o tempo gasto na execução de 86 restaurações atraumáticas realizadas em pré-escolares de creches comunitárias do município de Porto Alegre, utilizando o cimento de ionômero de vidro de alta viscosidade (Vitro- Molar/DFL). Metodologia: foram selecionadas 42 crianças com necessidades restauradoras, inseridas em um programa educativo-preventivo. As respectivas restaurações foram avaliadas seguindo os critérios USPHS modificado e analisadas estatisticamente pelo teste não paramétrico Mann- Whitney (p<0,05). Resultados: encontrou-se 94,2% de retenção das restaurações envolvendo uma ou mais superfícies em dentes decíduos. O tempo médio despendido para execução da restauração foi de 4,47 minutos segundo análise de variância. Conclusão: concluí-se que as restaurações atraumáticas são indicadas para serem utilizadas em pré-escolares, por apresentarem um bom desempenho clínico e agilidade no atendimento. / Objective: the aim of the present study was to qualitatively assess the clinical performance, after 12 months, of 86 atraumatic restorations bonded with highviscosity glass ionomer cement (Vitro-Molar/DFL), in preschoolers from Porto Alegre-based day care centers, in southern Brazil, and also to assess the length of the treatment. Methods: a total of 42 children who required restorative treatment were selected from a preventive educational program. The restorations were assessed using the modified USPHS criteria and statistically analyzed by the nonparametric Mann-Whitney test (p<0.05). Results: the restorations on one or more surfaces of deciduous teeth had a retention rate of 94.2%. According to the analysis of variance, the length of restorative treatment averaged 4.47 minutes. Conclusion: atraumatic restorations are recommended in preschoolers, since they have a good clinical performance and allow prompt treatment.
99

Influência da adição de fosfato octacálcico, alfa-fosfato tricálcico ou hidroxiapatita nas propriedades de um cimento de ionômero de vidro

Santos, Paula Dapper January 2015 (has links)
O protocolo moderno de tratamento da doença cárie está baseado na intervenção minimamente invasiva, que pode lançar mão da remoção parcial de tecido cariado para reduzir os riscos de problemas pós-operatórios. Por possuir capacidade de aderir aos subtratos dentários, os cimentos de ionômero de vidro apresentam indicação para esse processo. Em contrapartida, fosfatos cálcicos apresentam potencialidade de induzir deposição mineral. Sendo assim, o objetivo desse estudo foi avaliar o efeito da incorporação de fosfato octacálcico (OCP), α-fosfato tricálcico (α-TCP) ou hidroxiapatita (HA) sobre as propriedades de um cimento de ionômero de vidro comercial restaurador, bem como caracterizar a dentina bovina desmineralizada restaurada com esses materiais. Foram produzidos três grupos testes: GOCP, GTCP e GHA, por meio da substituição de 5% em massa do pó do cimento original, por 5% em massa de OCP, de α-TCP ou de HA, respectivamente. O grupo GCIV, sem alterações, foi o grupo controle. As propriedades avaliadas foram radiopacidade, tempo de presa inicial e profundidade de polimerização, de acordo com a ISO 9917-2:2010. A caracterização da dentina foi realizada através de microdureza Knoop e espectrocopia Raman, através da intensidade do pico 962 cm-1, para verificar-se a presença de fosfato no interior da dentina. Os resultados de radiopacidade foram equivalentes a 3 mmAl. O tempo de presa inicial variou entre 39,06 + 1,15 min, para o GCIV, e 58,39 + 2,64 min, para o GTCP. Na profundidade de polimerização, os valores variaram entre 1,61 + 0,04, para o GHA, e 1,77 + 0,04 mm, para o GTCP. Todos os resultados de radiopacidade, tempo de presa inicial e profundidade de polimerização foram de acordo com os preconizados pela norma. A dureza da dentina hígida foi superior tanto à dureza dos grupos que foram submetidos à restauração quanto à dureza da dentina desmineralizada. Mesmo sendo ilustrativas, as imagens obtidas da dentina dos diferentes grupos mostram intensidades variadas de fosfato, especialmente em relação à dentina hígida, permitindo inferir que, dentre os grupos desmineralizados, há maior intensidade no GHA. Pode-se concluir que a adição de fosfatos cálcicos não prejudicou as propriedades do cimento de ionômero de vidro comercial e que as imagens que representam a intensidade de fosfato no interior da dentina dos grupos sugerem que os materiais avaliados podem apresentar uma potencial ação indutora de deposição mineral. / The modern protocol for treating caries disease is based on minimal invasive intervention, which can employ incomplete caries removal, to reduce post-operatory problems. For bearing capacity to adhere to tooth substrate, the glass ionomer cement is indicated for this process. Furthermore, the calcium phosphates have potential to induce mineral deposition. Thus, the aim of this study was to evaluate the effect of the addition of octacalcium phosphate (OCP), αtricalcium phosphate (α-TCP), or nanostructured hydroxyapatite (HA) on the properties of commercial restorative glass ionomer cement, and to characterize demineralised bovine dentin restored with these materials. Three test groups were produced: GOCP, GTCP, and GHA, through the substitution of 5%, by mass, of original cement powder with 5%, by mass, of OCP, α-TCP or HA, respectively. The group GCIV, without alteration, was the control group. Radiopacity, initial hardening time, and depth of cure were the properties evaluated, all according to ISO 9917-2:2010. Dentin characterization was conducted using Knoop microhardness and Raman spectroscopy, through 962 cm-1 intensity peak, to verify phosphate existence in inner dentin. Radiopacity results were equivalent to 3 mmAl. Initial hardening time varied between 39.06 + 1.15 min, for GCIV, and 58.39 + 2.64 min, for GTCP. For depth of cure, values varied between 1.61 + 0.04 mm, for GHA, and 1.77 + 0.04 mm, for GTCP. All results of radiopacity, initial hardening time and depth of cure were according to what is established by the standard. Hard sound dentin values were superior both for restored groups hardness and for demineralised dentin hardness. Though illustrative, different groups dentin images show varied phosphate intensities, especially regarding sound dentin, allowing to infer that, among demineralised groups, there are higher intensity in GHA. Thus, it is possible to conclude that the addition of calcium phosphates did not impaired commercial glass ionomer cement properties and that groups images representing inner dentin phosphate intensity suggest that evaluated materials may present potential mineral deposition induction action.
100

Verniz fluoretado e ionômero de vidro modificado por resina no tratamento de lesões cariosas oclusais em esmalte de molares permanentes em erupção : ensaio clínico randomizado

Azevedo, Claudia Britto January 2015 (has links)
A erupção de molares permanentes é importante para o estabelecimento da doença cárie dentária. Embora a maioria das lesões de cárie oclusal tendem a inativar uma vez que os molares permanentes atingem o plano oclusal, estudos recentes têm mostrado que uma quantidade significativa destas lesões permanecem ativas, necessitando de um tratamento adequado. O objetivo deste estudo foi observar a efetividade do verniz fluoretado (Duraphat, Colgate) e do ionômero de vidro modificado por resina (ClinproXT, 3M) na inativação de lesões em esmalte em molares permanentes em erupção. Este ensaio clínico randomizado paralelo longitudinal foi realizado entre Junho de 2014 e julho de 2015. 64 molares (± 2,37 dentes por crianças) foram tratados (33 selados e 31 tratados com verniz fluoretado), e reavaliados após 3, 6, 9 e 12 meses. 97% das lesões seladas, e 74,2% das lesões que receberam aplicações de verniz fluoretado foram inativadas em um intervalo de 12 meses (p=0,04). A idade das crianças e as intervenções realizadas foram estatisticamente associadas com a paralização das lesões (modelo de regressão deWeibull Cox, p>0,05). Este estudo mostrou que os selantes de ionômero de vidro modificado por resina tiveram um melhor desempenho que aplicações de verniz fluoretado na inativação de lesões em esmalte ativas após um período de acompanhamento de 12 meses. / Background: Eruption of permanent molars is significantly important for the development of dental caries. Although most occlusal caries lesions tend to arrest when teeth reach the occlusal plan, recent studies have shown that an important proportion of these lesions remain active, and in need of proper management. Aim: The aim of this study was to investigate the effectiveness of resin modified glass ionomer cement for pit and fissures sealing (ClinproXT, 3M) and fluoride varnish (Duraphat, Colgate) on arresting enamel carious lesions, on erupting molars in different stages of eruption. Design: This randomized parallel longitudinal clinical study was carried out between June 2014 and June 2015. Results: 27 children and 64 molars (±2.37 teeth per children) were treated (33 sealed and 31 treated with fluoride varnish) and reassessed after 3, 6, 9 and 12 months. 97% of the lesions that were treated with ionomer cement sealant were arrested against 74.2% of the lesions that received fluoride varnish applications (p=0.04). Also, children’s age and treatment were significantly associated with occlusal lesion arrestment (Weibull Cox regression models, p>0.05). Conclusions: Resin modified glass ionomer cement sealants performed better than fluoride varnish applications on caries arrestment after a 12-month follow-up period.

Page generated in 0.0429 seconds