• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 80
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 87
  • 29
  • 26
  • 24
  • 24
  • 22
  • 19
  • 18
  • 17
  • 17
  • 14
  • 14
  • 14
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Preparação e caracterização de manganitas (La,Pr)CaMnO / Preparation and characterization of La,Pr)CaMnO manganites

Masunaga, Sueli Hatsumi 15 April 2005 (has links)
Amostras policristalinas de La(5/8-y)Pr(y)Ca(3/8)MnO(3); 0 y 0.625; foram produzidas pelo método da mistura estequiométrica de óxidos e tratadas termicamente ao ar a 1400 oC. As amostras foram caracterizadas através de medidas de difração de raios-X, resistividade elétrica rho(T), susceptibilidade magnética chi(T) e magnetorresistividade rho(T, H = 50 kOe). Os resultados das análises dos diagramas de raios-X indicaram que os materiais são de fase única e que houve uma substituição efetiva de La por Pr no sítio A ao longo da série. Medidas de rho(T) e chi(T) revelaram que a temperatura de transição de fase metal-isolante TMI e temperatura de Curie TC decrescem com o aumento da concentração y e que a resistividade residual rho0 (rho(T = 10 K)) é consideravelmente alta em amostras com y 0.35. Ainda, com o decréscimo de T, as amostras com y 0.35 transitam para uma fase de ordenamento de carga em TOC ~ 194 K e, em seguida, para uma fase metálica em TMI. Essas medidas também sugerem a coexistência de fases ferromagnética-metálica FMM e de ordenamento de carga isolante OCI nesses materiais. Nas propriedades físicas macroscópicas, a fase FMM mostrou ser a dominante para os compostos com pequenas concentrações de Pr (y 0.25) e a fase OCI dominante para os compostos com altas concentrações de Pr (y 0.40). As medidas de rho(T, H = 50 kOe) mostram que a magnitude da resistividade elétrica decresce drasticamente nas vizinhanças de TMI sob a aplicação de um campo magnético externo. A magnitude de MR (MR = (rho(H = 0)-rho(H = 50 kOe))/rho(H = 50 kOe)) entre os extremos da série (y = 0 e 0.625) varia até sete ordens de grandeza, sendo que o máximo valor de MR para amostras com y = 0 é de ~ 0.75 e naquelas com y = 0.625 é ~ 3.4x106 . O diagrama de fases deste composto evidencia uma região crítica (0.30 y 0.40) onde os valores de TMI, TC, MR e 0 variam abruptamente como função de y, sendo que em outras regiões tal variação é mais suave. A variação significativa desses quatro valores indica uma competição mais forte entre as fases coexistentes ocorre na região crítica. Algumas características marcantes podem ser observadas nas amostras da região crítica tais como: a presença de um segundo pico, abaixo de TMI, em ~ 90 K e ~ 72 K na curva de rho(T) de amostras com y = 0.30 e 0.35, histerese térmica mais pronunciada em rho(T) e chi(T), MR torna-se colossal, relaxação significativa da resistividade elétrica com o tempo, entre outras. Assim, as propriedades de transporte e magnéticas nessa região crítica são dominadas pela forte competição entre as fases coexistentes. / Polycrystalline samples of La(5/8-y)Pr(y)Ca(3/8)MnO(3); 0 y 0.625; were synthesized by the solid-state reaction method and sintered in air at 1400 oC. These compounds were studied by measurements of X-ray powder diffraction, magnetic susceptibility chi(T), and electrical resistivity rho(T, H). X-ray powder diffraction measurements indicated single phase materials and an effective substitution of La by Pr. Results from rho(T) and chi(T) revealed that increasing y in this series results in a rapid reduction of both the insulator to metal transition temperature TMI and the Curie temperature TC. Such a rapid decrease in TMI with increasing y is also accompanied by the occurrence of a new transition temperature, termed TCO, which is related to the transition to the charge ordered CO state. Such a temperature, which is essentially independent of y, occurs at TCO ~ 194 K and is mainly observed in samples with y 0.35. The other feature is the presence of a large residual resistivity electrical rho(0 = (10 K)) for large y (y 0.35) at low-T even though rho(T) suggests a metallic behavior below TMI. The temperature for the maximum magnetoresistance effect occurs near TMI, that shifts to higher T with increasing field. The MR is defined here as (rho(H = 0)-rho(H = 50 kOe))/rho(H = 50 kOe) and is enhanced by seven orders of magnitude from ~ 0.75 up to ~ 3.4x106 in samples with y = 0 and y = 0.625, respectively. Some features like the thermal hysteresis observed in both rho(T) and chi(T) curves indicate the coexistence of different phases in a range of y concentration, i. e., the ferromagnetic-metallic FMM and the charge ordered-insulating COI domains. The FMM is stable for y 0.25, but the COI state becomes dominant for y 0.40. There is a critical region in the phase diagram, ranging from y = 0.30 to 0.40, where the magnitude of the TMI, TC, MR, and 0 were found to display abrupt changes with increasing y. Some anomalous features like a second peak in rho(T) below TMI, a two-step increasing in chi(T), a colossal MR effect and others are observed for compositions belonging to this critical region. Our combined data suggest that the general physical properties of these compounds in such a critical region are dominated by the strong competition between coexisting ferromagnetic-metallic and charge ordered-insulating phases.
52

Determinação de gases combustíveis em óleo isolante para transformadores, por meio de aquecimento prévio / Determination of combustible gases in insulating oil for power transformers by previous heating

Gouveia, Dênis Augusto Genaro 05 May 2008 (has links)
Os transformadores de potência são alguns dos elementos mais importantes dos sistemas elétricos. A confiabilidade e o bom funcionamento destes equipamentos são vitais para que as companhias de energia forneçam eletricidade com qualidade e segurança. Um dos principais parâmetros que envolvem a normalidade da operação dos transformadores é o estado da isolação interna formada pelo óleo mineral e o papel que cobre as bobinas. Danos nessa isolação resultam na degradação destes dielétricos e, por conseqüência, na diminuição da vida útil dos transformadores. Essa degradação, que advém de processos elétricos, térmicos, ou mesmo mecânicos, geram gases combustíveis cujas quantidades individuais podem indicar o tipo de falha e a gravidade do problema. Desta forma, é importante detectar os principais gases envolvidos. O objetivo deste trabalho é realizar análises e estudos quantitativos da presença de gases inflamáveis dissolvidos no óleo, surgidos através da degradação deste líquido isolante. O cerne deste trabalho está em elaborar ensaios de formação de arco no óleo e, posteriormente, aquecer o fluido para medir a quantidade dos gases combustíveis antes dissolvidos nele. Este estudo visa à melhoria na confiabilidade dos equipamentos projetados para detectar e monitorar o surgimento de gases inflamáveis no interior de transformadores de potência existentes em subestações de companhias de eletricidade. / Power transformers are some of the most important elements of electrical systems. The trustworthiness and the good functioning of this equipment permit power utilities to supply electricity with quality and security. One of the main parameters for transformer\'s operation normality is the state of the internal insulation formed by the mineral oil and the paper that covers the bobbins. Damages in this insulation cause its dielectric degradation and, consequently, the reduction of the equipment useful life. This degradation which originates from electrical, thermal, or even mechanical processes generates chemical products such as gases whose individual amounts may indicate the type of imperfection and gravity of the problem. That\'s why the detection of the main involved gases is important. This work intends to elaborate analyses and studies of the presence of inflammable gases dissolved in oil through the degradation of the insulating liquid. The principal topic of this work is the arc formation elaboration in the oil and later the heating of the oil to measure the amount of gases previously dissolved in it. This study also aims to improve the trustworthiness of the projected equipments in order to detect and monitor the sprouting of existing inflammable gases in the interior of power transformers in substations of power utilities.
53

Compactação e elevação da vida útil de transformadores de distribuição empregando óleo vegetal isolante. / Reduction and extension life of distribution transformers using insulating vegetable oil.

Vasconcellos, Vagner 14 April 2016 (has links)
A busca no aumento da vida útil dos transformadores de distribuição, redução dos custos de manutenção e mitigação de falhas, leva ao desenvolvimento de novos materiais e critérios de exploração diferenciados desses ativos. Esta pesquisa apresenta o desenvolvimento de um novo transformador de distribuição compacto e mais eficiente utilizando óleo vegetal isolante totalmente biodegradável. Além de biodegradável, o óleo vegetal utilizado possui menor agressividade ambiental e maior capacidade térmica aumentando, a capacidade de carregamento do transformador sem comprometer a sua vida útil. A fim de atestar essa menor agressividade em relação ao óleo mineral, ensaios foram efetuados em um equipamento que permaneceu 12 anos em operação. O equipamento foi totalmente desmontado para análise e coleta de amostras de papel e óleo vegetal isolante. As análises visam comprovar a menor agressividade em relação ao óleo mineral, apresentadas na revisão bibliográfica. A menor agressividade torna possível a proposição de uma nova filosofia de planejamento de redes de distribuição utilizando uma quantidade menor dos novos transformadores para uma mesma carga, tornando-a mais compacta e eficiente. / The search of increase on the life expectancy of distribution transformers, reducing maintenance costs and mitigation failures, leads to the development of new materials and different operating criteria of these assets. This research presents the development of a new distribution transformer compact and more efficient with insulating in vegetable oil totally biodegradable. In addition to biodegradable, the vegetable oil used has less environmental aggressiveness and greater thermal capacity, increasing the loading capacity of the transformer without compromising its life expectancy. To prove that the vegetable oil is less aggressive than mineral oil, tests were done out in a transformer that worked for 12 years. The equipment was disassembled for analysis and collection of samples of vegetable oil and paper insulation. The analyses aim to prove the lesser aggressiveness compared to mineral oil, presented in the literature review. This situation makes it possible the proposition of a new philosophy of planning of distribution networks using a smaller amount of new transformers for the same load, making it more compact and efficient.
54

Estudos sobre gases dissolvidos em óleos vegetais isolantes - influência de arco elétrico e superaquecimento / Dissolved gases analysis in insulating oils - the influence of electric arc and overheating

Leopoldino, Reginaldo 14 April 2011 (has links)
A inovação tecnológica é uma ferramenta muito poderosa utilizada para avançar estrategicamente no mundo competitivo. Esta tendência também é uma realidade nos sistemas de isolamento dos transformadores. Os isolamentos passam então a ser avaliados tanto do ponto de vista econômico, quanto do ambiental e da segurança. Em todo o mundo, são consumidos bilhões de litros de óleo isolante mineral e vegetal que, juntamente com o papel, formam a isolação interna dos equipamentos. Essa isolação ao ser degradada por uma ação térmica, química ou elétrica, não só diminui a vida útil dos equipamentos, mas também aumenta a taxa de falha e acarreta prejuízos e multas severas às concessionárias de energia. Aumenta-se a urgência em explorar o uso de óleos não fósseis, renováveis e biodegradáveis. Os fluídos isolantes vegetais, com capacidade de reduzir incêndios e riscos ambientais, já são uma realidade e alternativa possível em substituição aos óleos isolantes minerais. Como são de uso recente, os estudos sobre os gases dissolvidos nesses óleos ainda são poucos e seu uso como elementos indicadores de faltas causam desconfiança. Assim, o objetivo do trabalho foi o de criar metodologias para produzir em laboratório arcos elétricos e superaquecimento em óleos, capazes de gerar gases dissolvidos. Depois por ensaios térmicos e elétricos, realizaram-se estudos comparativos entre óleo mineral e vegetal com as técnicas disponíveis para monitoramento de faltas em transformadores. / Technological innovation is a very powerful tool used to advance strategically in the competitive world. This trend is also a reality in the insulation systems of transformers. Thus, insulation systems both from an economic, environmental and security viewpoint. Around the world are consumed billions of liters of insulating oil which jointly to paper forms the internal equipments insulation. When this insulation is damaged by thermal, chemical or electrical reaction it reduces the equipment durability, increases its failure rates, and cause great losses and severe fines to Electricity dealers. Consequently, this increases the urgency to explore the use of non-fossil oil, renewable and biodegradable. The vegetable insulating fluids is less-flammable and presents less environmental hazards, so it is a viable alternative to replace the use of mineral insulating oils. However, considering its recent use, studies involving dissolved gases in these oils are still scarce, and its use as shortages indicator, today, cause a deep distrust. Thus, the aim of this study was to create methodologies to produce, in laboratory, electric arcs and overheating in oils capable of generating dissolved gases. After a trial, was carried out a comparative analysis between mineral and vegetable oils, using the techniques available for monitoring transformers failures.
55

Modelagem e simulação da decomposição térmica do óleo mineral isolante aplicadas à classificação de defeitos em transformadores de potência / Modeling and simulation of the mineral insulating oil thermal decomposition applied to faults classification in power transformers

Vinicius Gabriel Macedo Cruz 20 February 2015 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / A análise de gases dissolvidos tem sido aplicada há décadas como a principal técnica de manutenção preditiva para diagnosticar defeitos incipientes em transformadores de potência, tendo em vista que a decomposição do óleo mineral isolante produz gases que permanecem dissolvidos na fase líquida. Entretanto, apesar da importância desta técnica, os métodos de diagnóstico mais conhecidos são baseados em constatações de modelos termodinâmicos e composicionais simplificados para a decomposição térmica do óleo mineral isolante, em conjunto com dados empíricos. Os resultados de simulação obtidos a partir desses modelos não reproduzem satisfatoriamente os dados empíricos. Este trabalho propõe um modelo termodinâmico flexível aprimorado para mimetizar o efeito da cinética de formação de sólidos como restrição ao equilíbrio e seleciona, entre quatro modelos composicionais, aquele que apresenta o melhor desempenho na simulação da decomposição térmica do óleo mineral isolante. Os resultados de simulação obtidos a partir do modelo proposto apresentaram uma melhor adequação a dados empíricos do que aqueles obtidos a partir dos modelos clássicos. O modelo propostofoi, ainda, aplicado ao desenvolvimento de um método de diagnóstico com base fenomenológica.Os desempenhos desta nova proposta fenomenológica e de métodos clássicos de diagnóstico por análise de gases dissolvidos foram comparados e discutidos; o método proposto alcançou desempenho superior a vários métodos usualmente empregados nessa área do conhecimento. E, ainda, um procedimento geral para a aplicação do novo método de diagnóstico é descrito / The dissolved gas analysis has been applied for decades as the main predictive maintenance technique for diagnosing incipient faults in power transformers since the decomposition of the mineral insulating oil produces gases that remain dissolved in the liquid phase. Nevertheless, the most known diagnostic methods are based on findings of simplified thermodynamic and compositional models for the thermal decomposition of mineral insulating oil, in addition to empirical data. The simulations results obtained from these models do not satisfactorily reproduce the empirical data. This work proposes a flexible thermodynamic model enhanced to mimic the kinetic effect of solid formation as a restriction to equilibrium and selects, among four compositional models, the one offering the best performance on the simulation of the thermal decomposition of mineral insulating oil. The simulation results obtained from the proposed model showed better adequacy to reported data than the results obtained from the classical models. The proposed model was also applied in the development of a diagnostic method with a phenomenological basis. The performances of this new phenomenological proposition and of classical dissolved gas analysis diagnostic methods are compared and discussed; the proposed method achieved a performance superior to several methods usually employed in this area of knowledge.Also, a general procedure for the application of the new diagnostic method is described
56

Estudos sobre gases dissolvidos em óleos vegetais isolantes - influência de arco elétrico e superaquecimento / Dissolved gases analysis in insulating oils - the influence of electric arc and overheating

Reginaldo Leopoldino 14 April 2011 (has links)
A inovação tecnológica é uma ferramenta muito poderosa utilizada para avançar estrategicamente no mundo competitivo. Esta tendência também é uma realidade nos sistemas de isolamento dos transformadores. Os isolamentos passam então a ser avaliados tanto do ponto de vista econômico, quanto do ambiental e da segurança. Em todo o mundo, são consumidos bilhões de litros de óleo isolante mineral e vegetal que, juntamente com o papel, formam a isolação interna dos equipamentos. Essa isolação ao ser degradada por uma ação térmica, química ou elétrica, não só diminui a vida útil dos equipamentos, mas também aumenta a taxa de falha e acarreta prejuízos e multas severas às concessionárias de energia. Aumenta-se a urgência em explorar o uso de óleos não fósseis, renováveis e biodegradáveis. Os fluídos isolantes vegetais, com capacidade de reduzir incêndios e riscos ambientais, já são uma realidade e alternativa possível em substituição aos óleos isolantes minerais. Como são de uso recente, os estudos sobre os gases dissolvidos nesses óleos ainda são poucos e seu uso como elementos indicadores de faltas causam desconfiança. Assim, o objetivo do trabalho foi o de criar metodologias para produzir em laboratório arcos elétricos e superaquecimento em óleos, capazes de gerar gases dissolvidos. Depois por ensaios térmicos e elétricos, realizaram-se estudos comparativos entre óleo mineral e vegetal com as técnicas disponíveis para monitoramento de faltas em transformadores. / Technological innovation is a very powerful tool used to advance strategically in the competitive world. This trend is also a reality in the insulation systems of transformers. Thus, insulation systems both from an economic, environmental and security viewpoint. Around the world are consumed billions of liters of insulating oil which jointly to paper forms the internal equipments insulation. When this insulation is damaged by thermal, chemical or electrical reaction it reduces the equipment durability, increases its failure rates, and cause great losses and severe fines to Electricity dealers. Consequently, this increases the urgency to explore the use of non-fossil oil, renewable and biodegradable. The vegetable insulating fluids is less-flammable and presents less environmental hazards, so it is a viable alternative to replace the use of mineral insulating oils. However, considering its recent use, studies involving dissolved gases in these oils are still scarce, and its use as shortages indicator, today, cause a deep distrust. Thus, the aim of this study was to create methodologies to produce, in laboratory, electric arcs and overheating in oils capable of generating dissolved gases. After a trial, was carried out a comparative analysis between mineral and vegetable oils, using the techniques available for monitoring transformers failures.
57

Determinação de gases combustíveis em óleo isolante para transformadores, por meio de aquecimento prévio / Determination of combustible gases in insulating oil for power transformers by previous heating

Dênis Augusto Genaro Gouveia 05 May 2008 (has links)
Os transformadores de potência são alguns dos elementos mais importantes dos sistemas elétricos. A confiabilidade e o bom funcionamento destes equipamentos são vitais para que as companhias de energia forneçam eletricidade com qualidade e segurança. Um dos principais parâmetros que envolvem a normalidade da operação dos transformadores é o estado da isolação interna formada pelo óleo mineral e o papel que cobre as bobinas. Danos nessa isolação resultam na degradação destes dielétricos e, por conseqüência, na diminuição da vida útil dos transformadores. Essa degradação, que advém de processos elétricos, térmicos, ou mesmo mecânicos, geram gases combustíveis cujas quantidades individuais podem indicar o tipo de falha e a gravidade do problema. Desta forma, é importante detectar os principais gases envolvidos. O objetivo deste trabalho é realizar análises e estudos quantitativos da presença de gases inflamáveis dissolvidos no óleo, surgidos através da degradação deste líquido isolante. O cerne deste trabalho está em elaborar ensaios de formação de arco no óleo e, posteriormente, aquecer o fluido para medir a quantidade dos gases combustíveis antes dissolvidos nele. Este estudo visa à melhoria na confiabilidade dos equipamentos projetados para detectar e monitorar o surgimento de gases inflamáveis no interior de transformadores de potência existentes em subestações de companhias de eletricidade. / Power transformers are some of the most important elements of electrical systems. The trustworthiness and the good functioning of this equipment permit power utilities to supply electricity with quality and security. One of the main parameters for transformer\'s operation normality is the state of the internal insulation formed by the mineral oil and the paper that covers the bobbins. Damages in this insulation cause its dielectric degradation and, consequently, the reduction of the equipment useful life. This degradation which originates from electrical, thermal, or even mechanical processes generates chemical products such as gases whose individual amounts may indicate the type of imperfection and gravity of the problem. That\'s why the detection of the main involved gases is important. This work intends to elaborate analyses and studies of the presence of inflammable gases dissolved in oil through the degradation of the insulating liquid. The principal topic of this work is the arc formation elaboration in the oil and later the heating of the oil to measure the amount of gases previously dissolved in it. This study also aims to improve the trustworthiness of the projected equipments in order to detect and monitor the sprouting of existing inflammable gases in the interior of power transformers in substations of power utilities.
58

Um método fuzzy para programação de inspeções em transformadores baseado na análise de gases combustíveis e parâmetros físico-químicos do óleo isolante

PANTOJA, Márcia Priscila Furtado 24 October 2014 (has links)
Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-08-01T18:27:35Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_MetodoFuzzyProgramacao.pdf: 1961477 bytes, checksum: 0e45134ec2cdbd20250082208e7a2705 (MD5) / Approved for entry into archive by Irvana Coutinho (irvana@ufpa.br) on 2017-08-21T16:44:05Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_MetodoFuzzyProgramacao.pdf: 1961477 bytes, checksum: 0e45134ec2cdbd20250082208e7a2705 (MD5) / Made available in DSpace on 2017-08-21T16:44:05Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_MetodoFuzzyProgramacao.pdf: 1961477 bytes, checksum: 0e45134ec2cdbd20250082208e7a2705 (MD5) Previous issue date: 2014-10-24 / Eletronorte - Centrais Elétricas do Norte do Brasil S/A / Transformadores de potência que utilizam óleo para a isolação de suas partes internas necessitam de um programa de manutenção periódico que vise detectar possíveis falhas, tais como: deterioração da celulose do isolamento dos enrolamentos, curto circuito entre espiras, gases dissolvidos no óleo devido a sua degeneração, etc. Normalmente, programas de manutenção preventiva têm sido utilizados por empresas de geração, transmissão e distribuição de energia elétrica buscando evitar que estas falhas venham a provocar a retirada do equipamento do sistema elétrico, situação que implica em grandes perdas financeiras, seja pela diminuição do faturamento, pelo pagamento de multas à agência reguladora, além da diminuição da confiabilidade do sistema. Para evitar estes tipos de perdas, este trabalho apresenta uma proposta de solução, usando abordagem Fuzzy, para auxiliar o processo de programação de inspeções em transformadores de alta potência (500kv), por meio da análise dos gases dissolvidos no óleo isolante, obtidos pela técnica da cromatografia gasosa e da análise físico-química do óleo. Buscou-se produzir uma solução que combine os resultados dos métodos tradicionais já consolidados na literatura, com situações adicionais oriundas da análise físico-química do óleo e do conhecimento dos especialistas, de forma a aumentar a eficácia do procedimento de inspeção desses equipamentos. Com isso, qualquer Sistema Elétrico de Potência – SEP – que realiza diagnósticos em transformadores por meio da Norma NBR 7274, tende a obter um diagnóstico mais preciso, em decorrência da associação da análise físico-química do óleo isolante com a cromatografia gasosa e o conhecimento tácito de especialistas da área, possibilitando a expansão da base de regras original da referida norma técnica. Todos os testes e a base de dados utilizada são oriundos de um laboratório de Química de várias subestações elétricas de uma concessionária de energia elétrica localizada em Barcarena – Pará – Brasil. / Power transformers using oil for insulation internal parts need periodic maintenance of a program aimed at detecting possible failures, such as deterioration of the winding insulation cellulose, short circuit between turns, gases dissolved in the oil due to its degeneration etc. Typically, preventive maintenance programs are used by companies for generation, transmission and distribution of electricity for avoiding these failures may result in removal of equipment from the electrical system, a situation that involves large financial losses, either by decreased billing at payment of penalties to the regulatory agency, as well as reduced system reliability. To avoid these types of losses, this paper presents a proposed solution using fuzzy approach, to assist the process of inspections programming in high power transformers (500kv), through the analysis of gases dissolved in insulating oil, obtained by the technique gas chromatography and physico-chemical analysis of the oil. We attempted to produce a solution that combines the results of traditional methods already established in the literature, with additional situations originating from the physico-chemical analysis of the oil and knowledge of experts in order to increase the effectiveness of such equipment inspection procedure. With this, any Electric Power System - SEP - that performs diagnostics on transformers by NBR 7274, tends to get a more accurate diagnosis, due to the association of physical-chemical analysis of the insulating oil with gas chromatography and knowledge tacit from specialists, enabling us to expand the base of original rules of that technical standard. All tests and the database used were from a laboratory of Chemistry of various electrical substations of an power company located in Barcarena - Pará - Brazil.
59

Efeitos de dopagem e desordem em modelos de sistemas eletrônicos correlacionados

Carvalho, Rubens Diego Barbosa de January 2014 (has links)
Elétrons em bandas estreitas de energia são fortemente afetados pela interação coulombiana como também por desordem na rede. Ambos os efeitos podem levar à localização, mas de naturezas diferentes: estado isolante de Mott, induzido por correlação, e localização de Anderson, induzida por desordem. A existência da fase de Mott ´e também significativamente dependente do preenchimento da banda. Abordagens teóricas para lidar com esse tipo de sistema são usualmente baseadas no hamiltoniano de Hubbard ou modelos relacionados, incluindo desordem como uma distribuição de energias locais. Neste trabalho, utilizando a Teoria de Campo Médio Dinâmico (DMFT), estudamos o modelo de Anderson-Falicov-Kimball e sua versão de três bandas, obtida como uma simplificação do modelo de Hubbard de três bandas associado aos planos de CuO2 dos cupratos supercondutores de alta temperatura crítica, realizando nossa análise para os casos magnético e não magnético. A densidade de estados de uma partícula é obtida por medias aritmética e geométrica sobre a desordem, já que somente a última pode detectar a localização na ausência de um gap de energia. Variando as intensidades de interação coulombiana e desordem, construímos diagramas de fases para esse modelo, onde identificamos transições metal-isolante mediadas por correlação e desordem, bem como a inter-relação entre esses efeitos. Isso é feito para vários preenchimentos de banda, já que nosso principal interesse aqui é estudar como a variação da densidade de elétrons (dopagem) afeta os diagramas de fases previamente obtidos na ausência de dopagem. Para o modelo de uma banda no caso paramagnético, as informações reveladas pela densidade de estados são confirmadas pela análise das condutividades estática e dinâmica, incluindo efeitos de temperatura. Quando consideramos a solução magnética, observamos o comportamento da temperatura de Néel e podemos apresentar um diagrama de fases mais completo. Além de uma análise bastante extensa do modelo de uma banda, fazemos um estudo inicial do modelo de três bandas, focalizando comportamentos que possam vir a ser comparados ao que se observa nos óxidos supercondutores. / Electrons in narrow-band solids are strongly affected by the Coulomb interaction as well as lattice disorder. Both effects can lead to localization, but of different nature: correlation-induced Mott insulating state, and disorder-induced Anderson localization. The existence of the Mott phase is also significantly dependent on the band filling. Theoretical approaches to deal with this kind of system are usually based on the Hubbard Hamiltonian or related models, including disorder as a distribution of the on-site energies. In this work, utilizing Dynamic Mean Field Theory (DMFT), we study the Anderson- Falicov-Kimball and its three-band version, obtained as a simplification of the three-band Hubbard model associated to the CuO2 planes of high-critical-temperature cuprate superconductors, performing our analysis for the magnetic and non-magnetic cases. The one-particle density of states is obtained by both arithmetic and geometrical averages over disorder, since only the latter can detect localization in the absence of an energy gap. Varying the strengths of Coulomb interaction and disorder, we construct phase diagrams for these models, where we identify metal-insulator transitions driven by correlation and disorder, as well as the interplay between these effects. This is done for various band fillings, since our main interest here is to study how the variation of the electron density affects the phase diagrams previously obtained in the absence of doping. For the one-band model in the paramagnetic case, the picture revealed by the density of states is further checked by evaluating the static and dynamic conductivities, including temperature effects. When we consider the magnetic solution, we observe the N´eel temperature behavior, and we are able to present a more complete phase diagram. Besides a quite extensive analysis of the one-band model, we develop an initial study of the threeband model, focusing on behaviors that might be linked with what is observed on the superconducting oxides.
60

Estudo do modelo de Bose-Hubbard usando o algoritmo Worm / Study of the Bose-Hubbard model using the Worm algorithm

Costa, Karine Piacentini Coelho da 05 September 2011 (has links)
Nesta dissertação estudaremos sistemas de bósons ultrafrios armadilhados em uma rede ótica quadrada bidimensional sem levar em consideração o confinamento harmônico. A dinâmica desses sistemas é bem descrita pelo modelo de Bose-Hubbard, que prevê uma transição de fase quântica de um superfluido para um isolante de Mott a temperaturas baixas, e pode ser induzida variando a profundidade do potencial da rede ótica. Apresentaremos o diagrama de fases dessa transição construído a partir de uma aproximação de campo médio e também com um cálculo numérico usando um algoritmo de Monte Carlo Quântico, denominado algoritmo Worm. Encontramos o ponto crítico para o primeiro lobo de Mott em ambos os casos, concordando com trabalhos anteriores. / This work study the two-dimensional ultracold bosonic atoms loaded in a square optical lattice, without harmonic confinement. The dynamics of this system is described by the Bose-Hubbard model, which predicts a quantum phase transition from a superfluid to a Mott-insulator at low temperatures that can be induced by varying the depth of the optical potential. We present here the phase diagram of this transition built from a mean field approach and from a numerical calculation using a Quantum Monte Carlo algorithm, namely the Worm algorithm. We found the critical transition point for the first Mott lobe in both cases, in agreement with the standard literature.

Page generated in 0.1009 seconds