• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 624
  • 215
  • 80
  • 75
  • 67
  • 22
  • 13
  • 12
  • 11
  • 10
  • 10
  • 4
  • 4
  • 4
  • 3
  • Tagged with
  • 1436
  • 188
  • 182
  • 180
  • 174
  • 123
  • 120
  • 112
  • 108
  • 103
  • 96
  • 93
  • 87
  • 71
  • 69
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1131

Einfluss zweier Bandscheibenprothesen auf die Kinematik des C3/C4-Segmentes / Influence of two different types of total disc arthroplasty on the kinematic properties of C3/C4-segments

Wagner, Markus 17 September 2014 (has links)
No description available.
1132

Analyse cinématique 3D de la coordination des articulations de l'épaule par l'entremise du rythme scapulo-huméral

Robert-Lachaîne, Xavier 07 1900 (has links)
L'épaule est souvent affectée par des troubles musculo-squelettiques. Toutefois, leur évaluation est limitée à des mesures qualitatives qui nuisent à la spécificité et justesse du diagnostic. L'analyse de mouvement tridimensionnel pourrait complémenter le traitement conventionnel à l'aide de mesures quantitatives fonctionnelles. L'interaction entre les articulations de l'épaule est estimée par le rythme scapulo-huméral, mais la variabilité prononcée qu'il affiche nuit à son utilisation clinique. Ainsi, l'objectif général de cette thèse était de réduire la variabilité de la mesure du rythme scapulo-huméral. L'effet de la méthode de calcul du rythme scapulo-huméral et des conditions d'exécution du mouvement (rotation axiale du bras, charge, vitesse, activité musculaire) ont été testées. La cinématique des articulations de l'épaule a été calculé par chaîne cinématique et filtre de Kalman étendu sur des sujets sains avec un système optoélectronique. La méthode usuelle de calcul du rythme scapulo-huméral extrait les angles d'élévation gléno-humérale et de rotation latérale scapulo-thoracique. Puisque ces angles ne sont pas co-planaires au thorax, leur somme ne correspond pas à l'angle d'élévation du bras. Une nouvelle approche de contribution articulaire incluant toutes les rotations de chaque articulation est proposée et comparée à la méthode usuelle. La méthode usuelle surestimait systématiquement la contribution gléno-humérale par rapport à la méthode proposée. Ce nouveau calcul du rythme scapulo-huméral permet une évaluation fonctionnelle dynamique de l'épaule et réduit la variabilité inter-sujets. La comparaison d'exercices de réadaptation du supra-épineux contrastant la rotation axiale du bras a été réalisée, ainsi que l'effet d'ajouter une charge externe. L'exercice «full-can» augmentait le rythme scapulo-huméral et la contribution gléno-humérale ce qui concorde avec la fonction du supra-épineux. Au contraire, l'exercice «empty-can» augmentait la contribution scapulo-thoracique ce qui est associé à une compensation pour éviter la contribution gléno-humérale. L'utilisation de charge externe lors de la réadaptation du supra-épineux semble justifiée par un rythme scapulo-huméral similaire et une élévation gléno-humérale supérieure. Le mouvement de l'épaule est souvent mesuré ou évalué en condition statique ou dynamique et passive ou active. Cependant, l'effet de ces conditions sur la coordination articulaire demeure incertain. La comparaison des ces conditions révélait des différences significatives qui montrent l'importance de considérer les conditions de mouvement pour l'acquisition ou la comparaison des données. / The shoulder is often afflicted by musculo-skeletal diseases. However, shoulder evaluation is limited to qualitative measures affecting the specificity and accuracy of diagnosis. Three-dimensional motion analysis could complement conventional treatment with quantitative functional measures. The interaction between shoulder joints is estimated by the scapulo-humeral rhythm, but its pronounced variability of measurement ampers appropriate clinical use. Hence, the main objective of the thesis was to reduce the variability in the measure of the scapulo-humeral rhythm. The effect of the calculation method and conditions of motion (arm axial rotation, load, velocity, muscular activity) were tested on healthy subjects. Shoulder joints kinematics were obtained with an optoelectronic system using a kinematical chain and an extended Kalman filter. The common method of scapulo-humeral rhythm calculation extracts the angles of gleno-humeral elevation and scapulo-thoracic lateral rotation. Since these angles are not co-planar, their sum does not correspond to the arm elevation angle. A novel approach of joint contribution including all the rotations of each joint was developed and compared to the common method. The common method systematically overestimated gleno-humeral contribution in comparison to the proposed method. The new scapulo-humeral rhythm calculation allows a dynamic functional evaluation of the shoulder and reduces inter-subject variability. Shoulder coordination was compared on typical supraspinatus rehabilitation exercises contrasting in arm axial rotation, and the effect of adding external load was tested. The ''full-can'' exercise increased the scapulo-humeral rhythm and gleno-humeral contribution, which correspond to supraspinatus function. In contrast, the ''empty-can'' exercise increased scapulo-thoracic contribution, which is associated to compensation to avoid gleno-humeral contribution. The use of external load in supraspinatus rehabilitation seems justified by a similar scapulo-humeral rhythm and superior gleno-humeral elevation. Shoulder motion is often measured or evaluated in static or dynamic and passive or active conditions. However, the effect of these conditions on shoulder coordination remains uncertain. The comparison of these conditions revealed significant differences on shoulder kinematics showing the importance to consider conditions of motion for acquisition or comparison of data.
1133

Évaluation clinique et biomécanique de deux différents types d’arthroplastie totale de genou

Renaud, Alexandre 11 1900 (has links)
Différents dessins d’implants de prothèse totale de genou (PTG) sont utilisés en pratique clinique et chacun présente des caractéristiques biomécaniques spécifiques. Aucun implant n’a réussi à ce jour à reproduire parfaitement la biomécanique du genou naturel. Les objectifs de cette étude sont de comparer les résultats cliniques et biomécaniques tridimensionnels (3D) de deux types de PTG chez le même patient, puis de comparer la cinématique des PTG à celle d’un groupe de genoux asymptomatiques. Une cohorte de quinze patients avec un implant traditionnel dans un genou et un implant de nouvelle génération permettant un pivot dans le genou contralatéral a été étudiée. Le groupe contrôle était composé de trente-cinq genoux asymptomatiques. L’analyse de la cinématique 3D a été réalisée avec l’outil KneeKG (Emovi Inc. Canada) lors de la marche sur tapis roulant. L’évaluation clinique comprenait l’amplitude de mouvement ainsi que les questionnaires de perception articulaire, KOOS, Womac et SF-12. La comparaison de la cinématique des deux types de PTG a démontré quelques différences statistiquement significatives dans les plans sagittal et frontal alors que la comparaison des PTG et des genoux asymptomatiques a révélé plusieurs différences significatives dans les trois plans. Les scores cliniques des deux PTG ne comportaient pas de différence significative. Dans notre cohorte de patients, le design de l’implant a eu peu d’influence sur les résultats biomécaniques et cliniques. Les PTG n’ont pas reproduit une cinématique normale de genou. Beaucoup de travail et de recherche dans le développement de nouveaux implants sont encore nécessaires afin d’améliorer les résultats cliniques et de mieux reproduire la cinématique du genou naturel. / Various implants of total knee arthroplasty (TKA) are used in clinical practice and each presents specific biomechanical characteristics. No implant managed this day to reproduce perfectly the biomechanics of the natural knee. The objectives of this study are to compare the clinical and tridimensional (3D) biomechanical data of two different designs of TKA on the same patients and to compare the resulting 3D biomechanical data with those of asymptomatic knees. A cohort of fifteen patients with a traditional implant in one knee and an implant of new generation allowing a pivot in the contralateral knee was studied. The control group was composed of thirty-five asymptomatic knees. Assessment of 3D knee kinematics analysis was realized with the KneeKG (Emovi Inc. Canada) during treadmill gait. Clinical evaluation included range of motion as well as questionnaires of joint perception, KOOS, Womac and SF-12. Results showed some statistically significant differences in knee 3D kinematics of both TKAs in sagittal and frontal planes while comparison between TKAs and asymptomatic knees revealed several significant differences in all three planes. Clinical scores of both TKAs did not have significant difference. In our cohort of patients, TKA implant design had few measurable influences on kinematics during gait and on clinical results. TKA with these implants did not reproduce natural knee kinematics during gait. Significant research and development in new TKA designs are needed to improve clinical scores and reproduce natural knee kinematics.
1134

The biomechanics of turning gait in children with cerebral palsy

Dixon, Philippe Courtney January 2015 (has links)
Turning while walking is a crucial component of locomotion; yet, little is known about how the biomechanics of turning gait differ from those of straight walking. Moreover, it is unclear how populations with restricted gait ability, such as children with cerebral palsy (CP) adapt to turning, compared to their typically developing (TD) peers. Thus, the aims of this thesis were to quantify the biomechanical differences between turning gait and straight walking in TD children and to explore if further, pathology specific, changes present during turning in children with CP. Biomechanical data, including three-dimensional body motion, ground reaction forces, and muscle activity from both groups were collected during straight walking and 90 degree turning gait using motion capture technology. Experimental data were used to compute joint kinematics (angles) and joint kinetics (moments and power) as well as more novel measures to quantify turning fluency and dynamic stability. These data were also used to derive walking simulations using a musculo-skeletal model of the human body in order to quantify muscle contributions to medio-lateral center of mass (COM) acceleration. The results show that both groups preferred to redirect their body during turning about the inside, rather than the outside, limb (with respect to the turn center). For TD children, substantial biomechanical adaptations occurred during turning, compared to straight walking. Furthermore, turning gait simulations reveal that proximal (hip abductors) and distal (ankle plantarflexors) leg muscles were mainly responsible for the redirection of the COM towards the new walking direction during turning. For children with CP, the results suggest that turning gait may be better able to reveal gait abnormalities than straight walking for a number of kinematic and kinetic gait variables. Potentially, analysis of turning gait could improve the identification and management of gait abnormalities in children with CP.
1135

Méthode numérique d'estimation du mouvement des masses molles

Thouzé, Arsène 10 1900 (has links)
L’analyse biomécanique du mouvement humain en utilisant des systèmes optoélectroniques et des marqueurs cutanés considère les segments du corps comme des corps rigides. Cependant, le mouvement des tissus mous par rapport à l'os, c’est à dire les muscles et le tissu adipeux, provoque le déplacement des marqueurs. Ce déplacement est le fait de deux composantes, une composante propre correspondant au mouvement aléatoire de chaque marqueur et une composante à l’unisson provoquant le déplacement commun des marqueurs cutanés lié au mouvement des masses sous-jacentes. Si nombre d’études visent à minimiser ces déplacements, des simulations ont montré que le mouvement des masses molles réduit la dynamique articulaire. Cette observation est faite uniquement par la simulation, car il n'existe pas de méthodes capables de dissocier la cinématique des masses molles de celle de l’os. L’objectif principal de cette thèse consiste à développer une méthode numérique capable de distinguer ces deux cinématiques. Le premier objectif était d'évaluer une méthode d'optimisation locale pour estimer le mouvement des masses molles par rapport à l’humérus obtenu avec une tige intra-corticale vissée chez trois sujets. Les résultats montrent que l'optimisation locale sous-estime de 50% le déplacement des marqueurs et qu’elle conduit à un classement de marqueurs différents en fonction de leur déplacement. La limite de cette méthode vient du fait qu'elle ne tient pas compte de l’ensemble des composantes du mouvement des tissus mous, notamment la composante en unisson. Le second objectif était de développer une méthode numérique qui considère toutes les composantes du mouvement des tissus mous. Plus précisément, cette méthode devait fournir une cinématique similaire et une plus grande estimation du déplacement des marqueurs par rapport aux méthodes classiques et dissocier ces composantes. Le membre inférieur est modélisé avec une chaine cinématique de 10 degrés de liberté reconstruite par optimisation globale en utilisant seulement les marqueurs placés sur le pelvis et la face médiale du tibia. L’estimation de la cinématique sans considérer les marqueurs placés sur la cuisse et le mollet permet d'éviter l’influence de leur déplacement sur la reconstruction du modèle cinématique. Cette méthode testée sur 13 sujets lors de sauts a obtenu jusqu’à 2,1 fois plus de déplacement des marqueurs en fonction de la méthode considérée en assurant des cinématiques similaires. Une approche vectorielle a montré que le déplacement des marqueurs est surtout dû à la composante à l’unisson. Une approche matricielle associant l’optimisation locale à la chaine cinématique a montré que les masses molles se déplacent principalement autour de l'axe longitudinal et le long de l'axe antéro-postérieur de l'os. L'originalité de cette thèse est de dissocier numériquement la cinématique os de celle des masses molles et les composantes de ce mouvement. Les méthodes développées dans cette thèse augmentent les connaissances sur le mouvement des masses molles et permettent d’envisager l’étude de leur effet sur la dynamique articulaire. / Biomechanical analysis of human movement using optoelectronic system and skin markers considers body segments as rigid bodies. However the soft tissue motion relative to the bone, including muscles, fat mass, results in relative displacement of markers. This displacement is the results of two components, an own component which corresponds to a random motion of each marker and an in-unison component corresponding to the common movement of skin markers resulting from the movement of the underlying wobbling mass. While most studies aim to minimize these displacements, computer simulation models have shown that the movement of the soft tissue motion relative to the bones reduces the joint kinetics. This observation is only available using computer simulations because there are no methods able to distinguish the kinematics of wobbling mass of the bones kinematics. The main objective of this thesis is to develop a numerical method able to distinguish this different kinematics. The first aim of this thesis was to assess a local optimisation method for estimating the soft tissue motion using intra-cortical pins screwed into the humerus in three subjects. The results show that local optimisation underestimates of 50% the marker displacements. Also it leads to a different marker ranking in terms of displacement. The limit of local optimisation comes from the fact that it does not consider all the components of the soft tissue motion, especially the in-unison component. The second aim of this thesis was to develop a numerical method that accounts for all the component of the soft tissue motion. More specifically, this method should provide similar kinematics and estimate large marker displacement and distinguish the two components to conventional approaches. The lower limb is modeled using a 10 degree of freedom chain model reconstructed using global optimisation and the markers placed only on the pelvis and the medial face of the shank. The original estimate of joint kinematics without considering the markers placed on the thigh and on the calf avoids the influences of these markers displacement on the kinematic model reconstruction. This method was tested on 13 subjects who performed hopping trials and obtained up to 2.1 times of marker displacement depending the method considered ensuring similar joint-kinematics. A vector approach shown that marker displacements is more induce by the in-unison component. A matrix approach combining the local optimisation and the kinematic model shown that the wobbling mass moves around the longitudinal axis and along the antero-posterior axis of the bone. The originality of this thesis is to numerically distinguish the bone kinematics from the wobbling mass kinematics and the two components of the soft tissue motion. The methods developed in this thesis increases the knowledge on soft tissue motion and allow future studies to consider their movement in joint kinetics calculation.
1136

L’effet de la prothèse totale du genou sur la cinématique 3D : vers le développement de biomarqueurs mécaniques de la douleur

Larose, Gabriel 06 1900 (has links)
La prothèse totale du genou (PTG) est une chirurgie couramment pratiquée pour traiter les patients souffrant d’arthrose sévère du genou. Bien que cette technique chirurgicale soit efficace pour diminuer la douleur, améliorer la fonction du genou et rentable d’un point de vue socio-économique, un pourcentage non négligeable de patients n’est pas satisfait suite à la chirurgie, principalement due à une douleur persistante ou due à une perception d’avoir une mauvaise fonction articulaire, sans cause identifiée. Cependant, l’impact de cette chirurgie sur la cinématique tridimensionnelle (3D) du genou demeure mal compris. Dans le but de mieux comprendre pourquoi certains patients ressentent toujours de la douleur suite à cette chirurgie, cette étude analysera, dans un premier temps, l’effet prospectif de la chirurgie sur la cinématique 3D du genou. Puis dans un second temps, comparera la cinématique 3D de sujet souffrant de douleur à celle de sujets asymptomatiques suite à la prothèse. Pour parvenir à ces deux objectifs, deux études distinctes ont été entreprises. Une première étude prospective a porté sur l’évolution de la cinématique 3D du genou d’un groupe de 19 sujets, recrutés sur la liste d’attente pour prothèse totale du genou de deux chirurgiens du CHUM, hôpital Notre-Dame, puis la cinématique a été comparée avec un groupe contrôle de 17 sujets avec des genoux sains. Une seconde étude a comparé la cinématique 3D de 20 sujets souffrant de douleur post-PTG avec 20 sujets avec des genoux asymptomatiques suite à leur chirurgie. La première étude a permis de montrer que la cinématique dans le plan frontal suite à la prothèse totale du genou était corrigée vers celle des sujets sains. Contrairement à celle mesurée dans les autres plans (sagittal et axial) qui, malgré de petites corrections, demeure différente de la cinématique des sujets sains. La seconde étude a permis d’identifier un marqueur biomécanique de la douleur chez les sujets souffrant de douleur post-PTG. Effectivement, contrairement aux sujets asymptomatiques, suite à leur chirurgie, les patients souffrants de douleur marchent avec une contracture en flexion plus importante tout au long de la phase d’appui. Les résultats de ces deux études tendent à montrer que la prothèse totale du genou modifie la cinématique 3D du genou, sans toutefois redevenir semblable à celle d’un genou normal. De plus, certains marqueurs biomécaniques peuvent être associés à de la douleur suite à la chirurgie. Une meilleure compréhension de l’impact de la PTG sur la cinématique 3D du genou permettra d’offrir de meilleurs traitements en préparation et après la chirurgie et pourrait mener à de nouveaux designs de prothèses. / The total knee arthroplasty (TKA) is a common procedure in patients with severe knee osteoarthritis. This surgery has been proved to reduce pain, to improve knee function, and to be cost-effective. However, an important proportion of patients report insatisfaction, pain, and low articular function following the surgery. Moreover, even with this problem, the impact of the TKA on the tridimensional (3D) kinematics is not well understood. Therefore, two studies have been undertaken with the purpose of using the 3D kinematics to understand the post-TKA pain syndrome. During the first study, 19 subjects, recruited on a TKA waiting list of two surgeons of the CHUM, Hôpital Notre-Dame, were prospectively followed to measure the evolution of their 3D knee kinematics. A control group of 17 subjects with normal knees has also been recruited. The second study has compared 20 subjects with knee pain post-TKA with 20 subjects without pain post-TKA. The results of the first study tend to show an improvement in the frontal plan kinematics after the TKA toward the control group. However, the kinematics in the others plans still different of the control group. When the 3D kinematics of a group with pain is compared to a group without pain (second study), a biomechanical marker associated with pain was identified. The group with pain walk with a higher flexion contracture during the stance phase than the group without pain. Those results show that the total knee arthroplasty has an impact on the 3D kinematics; however, this impact is not necessarily toward the control group. Moreover, some biomechanical markers can be associated with the knee pain following the TKA. This show that we still doesn’t really understand the impact of the TKA on the kinematics, and that a better understanding of this impact could allow the surgeons to improve their care to their patients before and after the surgery.
1137

Případová studie involuce kinamatiky chůze a běhu / Case study of walk and run kinematics involution

Raková, Gabriela January 2015 (has links)
Title: Case study of walk and run kinematics involution Objectives: Identify differences in the execution of walk and run, their time and space parameters, by two couples in close family relationship (father and son; father and daughter), who participate in the performance sport of running. Methods: Two family couples (3 men and one woman) participated to laboratory and field tests. Each subject participated in two kind of walk (walk on treadmill at the speed of 5km/h and walk on the athletic track - at natural walking speed) and according the abilities to 15 speeds of running locomotion (13 speeds on treadmill and 2 speeds on the athletic track). Kinematics of all speeds was analysed with the software Kinovea 0.8.15. The thesis is a pilot study, that is trying to ascertain the extend of difference of the execution of locomotion of subjects in the male parental line (father and son; father and daughter). Results: Noticeable difference in the characteristics of all measured speeds of locomotion are seen by the older two members of relatives (74,8 and 40,2 years), the faster was the evaluated speed, the larger was the difference in stride length (6 to 25 cm) and in stride frequency in walking as well as in running (23 to 38 steps per minute). For the second tested two members of a family (53,7 and...
1138

Modélisation du squelette pour la génération réaliste de postures de la langue des signes française / Skeleton modelling for the realistic generation of french sign language postures

Delorme, Maxime 07 December 2011 (has links)
Les avancées récentes en matière d'animation ont permis le déploiement de personnages virtuels à des fins diverses et variées. Les signeurs virtuels sont des personnages en trois dimension s'exprimant en langue des signes et permettant la diffusion de messages aux personnes sourdes et malentendantes signantes de manière anonyme et modulaire. Cependant, la génération d'animations pour ces personnages dépend de la description lexicale des signes, modèle linguistique dépendant du système de génération. Les signes décrits par ces modèles sont généralement des réalisations parfaites et géométriques menant à des mouvements robotiques et peu naturels de la part du signeur. Cette thèse s'intéresse à l'addition d'informations anatomiques au squelette de contrôle du personnage virtuel de manière à le faire signer de manière plus humaine et réaliste. Ces informations supplémentaires sont regroupées sous l'appellation de "modèle anatomique" et sont divisées en cinq contributions principales : une nouvelle représentation informatique du squelette, une étude anthropométrique sur la main, l'unification de dépendances articulatoires, un nouveau modèle de complexe carpo-métacarpien permettant l'opposition aisée du pouce et enfin un modèle calculant le confort d'une posture. Ces apports sont intégrés à une plateforme de génération au moyen de techniques adaptées aux contraintes imposées par les modèles linguistiques. Les travaux sont conclus par une évaluation du système ainsi qu'une réflexion sur les travaux futurs pouvant être élaborés à partir de cette thèse. / Recent progresses in animation have allowed the use of virtual character to many extents. Virtual signers (or signing avatars) are three-dimension characters expressing themselves in sign language. These characters allow the the broadcasting of audio information to deaf and hearing-impaired signers in an anonymous and modular fashion. However, automatic generation of animation for such characters strongly rely on the lexical description of signs. Signs described through these models are usually perfect and geometric performances leading to robotic and unrealistic movements. These thesis focuses on adding information to the control skeleton of the signer to help him perform signs in a more human and realistic way. Such information are grouped under the name of "anatomic model" and are divided in five main contributions : a new computer-based description of the skeleton, an anthropometric study of the hand, the merging of articulatory dependencies, a new model of the carpo-metacarpal complex allowing an easier opposition of the thumb and finally a model computing posture comfort. These contributions are then implemented in a generation system through linguistic contraints-adapted techniques. The study ends with an evaluation of the system and a the presentation of future prospects.
1139

Efeito da suspensão frontal com fáscia muscular na cinemática palpebral / The effect of frontalis slings with muscular fascia in the eyelid\'s kinematics

Baccega, Adriano Antonio 18 May 2018 (has links)
O objetivo do estudo foi avaliar parâmetros da cinemática palpebral durante o piscar espontâneo e movimentos sacádicos palpebrais em pacientes com ptose congênita submetidos à correção cirúrgica pela técnica de suspensão frontal com fáscia muscular. Com um sistema de câmeras de captação infravermelha para análise tridimensional de movimentos foi feito registro simultâneo de movimentos de supercílio e de pálpebra. Para análise do piscar espontâneo foram avaliados 17 pacientes com ptose congênita que realizaram correção cirúrgica pela técnica de suspensão frontal com utilização de fáscia muscular autógena (n=14), e fáscia lata preservada (n=3), e para o estudo do movimento sacádico palpebral, a avaliação foi dos 14 pacientes que utilizaram apenas fáscia autógena. Um grupo controle com 17 indivíduos normais também foi medido. Para análise do piscar espontâneo um programa foi utilizado para medidas de amplitude e velocidade máxima de movimento durante a observação de um filme comercial por 5 minutos. Para análise do movimento sacádico palpebral foram realizadas medidas em 10, 20, 30, 40 e 50 graus do olhar para baixo. A avaliação da superfície ocular em lâmpada de fenda com utilização de fluoresceína foi realizada nos pacientes que apresentavam ou não lagoftalmo. O número de piscadelas foi significativamente diminuído nos pacientes. A distribuição do intervalo entre as piscadelas foi similar nos dois grupos. A média de amplitude da fase descendente do piscar dos pacientes foi apenas 38% da média do grupo controle. A inclinação da reta da \"main sequence\" para o piscar espontâneo para os pacientes foi mais baixa. Nos controles o movimento do supercilio foi muito pequeno e insignificante durante o piscar espontâneo. Nos pacientes, a média de amplitude do movimento do supercílio foi cinco vezes maior que nos controles chegando a 45% da amplitude do piscar. Os movimentos sacádicos palpebrais mostraram uma importante restrição e não aumentou além de 30 graus do olhar para baixo. A velocidade máxima da pequena amplitude dos movimentos sacádicos palpebral foi muito baixa. Enquanto a movimentação do supercilio no grupo controle ficou entre 3,3 e 9,3% do movimento sacadico palpebral, nos pacientes a movimentação do supercílio foi responsável por 43,5 a 57,4% do movimento palpebral. Lagoftalmo foi encontrado em 13 (76,5%) dos pacientes. Apenas 3 (23%) mostraram sinais de ceratopatia superficial inferior, apesar da presença do fenômeno de Bell. A amplitude e velocidade do piscar espontâneo está severamente diminuída em pacientes com suspensão frontal com fáscia muscular. Esse tipo de material causa um efeito restritivo permanente nas propriedades elásticas das pálpebras. Após a cirurgia a amplitude do piscar é dependente da amplitude do movimento do supercílio. O lagoftalmo é uma consequência natural da suspensão frontal com fáscia muscular. / The purpose of the present investigation was to measure lid kinematics parameters in spontaneous blink metrics and downward eyelid saccadic movements in patients with congenital ptosis operated with frontalis slings with muscles fascia. A optoeletronic system was employed with infrared 3-dimensional video motion analyzer to simultaneously measure brow motion and spontaneous blinks in 17 patients with congenital ptosis who underwent frontalis sling with autogeneous muscle fascia (n=14) and banked fascia lata (n=3). Downward eyelid saccadic movements were analyzed only in the 14 patients with autogeneous muscle fascia. A control group of equal number of healthy subjects was also measured. For analyses of spontaneous blinks, a customized software identified and quantified the amplitude and maximum velocity during 5 minutes observation of a commercial movie. For downward eyelid saccadic movements, 10, 20, 30, 40 and 50 degrees of downgaze were measure. The corneal status of the patients with and without lagophthalmos was evaluated with slit lamp biomicroscopy with fluorescein staining. Blink rate was significantly diminished in the patients. The distribution of interblink time was similar in both groups. The mean amplitude of the down phase of the patients\' blinks was only 38% of the controls. The main sequence slope of the patients´ blinks was abnormally low. In controls brow motion was a minute and random event no related to blinks. In the patients, the means brow amplitude was 5 times higher than in controls reaching 45% of the blink amplitude. The lid saccades of the patients were severely restricted and did not increase beyond 30 degrees of downgaze. The maximum velocity of the small amplitude lid saccades was also abnormally low. While in controls brow motion accounted for about 3,3 to 9,3% of the lid saccades, in the patients brow motion was responsible for more than 43,5% to 57,4% lid movements. Lagophthalmos was detected on 13 (76,5%) patients. Out of these 3 (23%) showed signs of inferior superficial keratopathy despite the presence of normal. Spontaneous blink amplitude and velocity are severely impaired in patients with fascia slings. This material has a permanent restrictive effect on the elastic properties of the lids. After surgery blinking amplitude is linearly related to the amplitude of brow motion. Postoperative lagophthalmos is a natural consequence of the slings with muscle fascia.
1140

Prototypframtagning av robotarm med sex axlar genom 3D-skrivning

Norstedt, Erik, Bräne, Olof January 2019 (has links)
3D-skrivare är inte längre något som endast stora företag har råd att använda sig av, utan någonting som har tagit sig ända till konsumentmarknaden. Detta har givit både hobbyanvändare och småföretag tillgång till ett kraftfullt verktyg för iterativ design. Det görs idag även stora framsteg inom robotik som ger upphov till möjligheter för tillämpningar av både industri- och konsumentrobotar i framtiden. Komplexiteten i robotar gör 3D-skrivare till användbara verktyg när det kommer till att ta fram robotprototyper. Målet med detta projekt var därför att analysera fördelar och nackdelar med 3D-skrivning i samband med prototypframtagning av en robotarm med sex axlar som kunde utföra enkla pick-and-place-rörelser. Roboten designades i Fusion360 och skrevs ut med 3D-skrivare i PETG. En Arduino MEGA användes till att styra stegmotorer i robotens axlar och styrningen implementerade en analytisk lösning till robotens kinematisk modell. Resultatet var en fungerande prototyp som kunde programmeras till att flytta och rotera föremål. Ett antal förbättringar av prototypen går att göra, till exempel går det att öka robotens rörlighet genom att designa om delar för att tillåta att axlar rotera längre och att implementera ytterligare funktionalitet i programmet som accelerationsrampning av stegmotorer och rörelse längs förvald bana. Utifrån analys av 3D-skrivningens inverkan på projektet framgick det att 3D-skrivning verkar användbart i prototypframtagning om dess möjlighet till iterativ design är önskvärd, men att det passar ännu bättre till mindre projekt då robotens storlek hindrade möjligheten till att utnyttja iterativ design till fullo och på så sätt hindrades även effektiviteten i 3D-skrivningsprocessen.

Page generated in 0.0824 seconds