• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 332
  • 203
  • 36
  • 18
  • 10
  • 9
  • 8
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 702
  • 258
  • 218
  • 213
  • 196
  • 152
  • 141
  • 120
  • 118
  • 103
  • 91
  • 81
  • 71
  • 68
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

AVFALLSMINIMERING / WASTE MINIMAZITION

Källström, Matilda, Lennartsson, Sofia January 2019 (has links)
Byggsektorn står idag för stora avfallsmängder, i Sverige år 2016 mättes ca 8,9 miljoner ton primärt bygg- och rivningsavfall upp. I Sverige så står byggsektorn för 31% av allt avfall som uppstått. Enligt Naturvårdsverket når inte Sverige upp till det nationella målet om minst 70% återvinning av bygg- och rivningsavfall som ska uppfyllas senast år 2020. Syftet är att ge en klar bild av hur avfallshanteringen utförs i byggproduktionen idag och var byggprojekt kan åstadkomma förbättringar inom produktion och projektering för att minska avfallet till deponi. Genom att minska avfallet till deponi ökar chansen att nå nationella målet om återvinning senast år 2020. En kvalitativ metod har använts i form av litteraturstudier samt ett platsbesök och tre intervjuer med tjänstemän från Skanska. Arbetet fokuserar på avfallshantering på arbetsplatsen men också på vad som kan förbättras under projekteringen. Endast nybyggen har studerats och arbetet omfattar endast vad som händer med materialet när det lämnar projektet för återanvändning, inte till deponi. I resultatet undersöks följande avfallsmetoder: hållbarhetskompetens, utbildning, avfallshanteringssystem, återtag av materialleverantör samt fraktionen blandat avfall. Lundprojektet använder samtliga. Kungsmässan-projektet använder sig av metoderna utbildning och ett bra avfallshanteringssystem. Utbildningen är av kortare variant som Skanska använder på samtliga byggprojekt. Avfallshanteringssystemet består av en anställd som har ansvar för avfallshanteringen. Regionens hus-projektet använder metoderna utbildning, återtag av materialleverantör samt har inte använt fraktionen blandat avfall. Utbildningen är den samma som nämndes för Kungsmässan-projektet. Projektet använde återtag av material med hjälp av leverantören men dock inte med så lyckat resultat. Byggarbetsplatsen har inte haft någon container för blandat avfall. För att lyckas med målet 0 kg avfall till deponi använder Lund-projektet en hållbarhetskompetens som finns tidigt i planeringen samt ett gediget avfallshanteringssystem med flera kontroller under produktionen. Projektet har upphandlat en sorteringsinriktad avfallsentreprenör och valt att utnyttja isoleringsleverantörens tjänst för återtag av oanvänd isolering. Resultatet visar att avfall till deponi kan minskas genom att: • Ha en hållbarhetskompetens i tidigt skede • Utbilda anställda • Använda ett bra avfallshanteringssystem • Försöka sortera i så stor utsträckning som möjligt och att undvika fraktionen blandat avfall • Utnyttja leverantörernas återtagstjänst. / The construction sector is currently responsible for a large amount of waste. In Sweden in 2016, approximately 8.9 million tons of primary construction and demolition waste were measured. In Sweden, the construction sector accounts for 31% of all waste generated. According to the Swedish Environmental Protection Agency, Sweden does not reach the national target of at least 70% recycling of construction and demolition waste to be met by 2020. The purpose is to give a clear picture of where construction projects can bring about improvements in production and design to reduce waste to landfill. By reducing waste to landfill, the chance of reaching the national recycling target can increase by 2020 at the latest. A qualitative method has been used in the form of literature studies and a site visit and three interviews with officials from Skanska. The work focuses on waste management at the workplace but also see what can be improved during the projection and planning phase in a project. Only new buildings have been studied and the work only covers what happens to the material when it leaves the project for reuse, not to landfill. The result examines the following waste methods: sustainability competence, education, waste management systems, withdrawal of material supplier and the fraction mixed waste. The Lund project uses all. The Kungsmässan project uses methods of education and a good waste management system. The education is of a shorter variant that Skanska uses on all construction projects. The waste management system consists of an employee who is responsible for waste management. The Regionens hus-project uses methods of education, recycling of material suppliers and has not used the fraction of mixed waste. The education is the same as mentioned for the Kungsmässan project. The project used retrieval of material with the help of the supplier, but not with so successful result. The construction site has not had any container for mixed waste. To succeed with the goal 0 kg of waste to landfill, the Lund project uses a sustainability competence that is early in the planning and a solid waste management system with several controls during production. The project has contracted a sorting waste disposal contractor and has chosen to utilize the insulation supplier's service for withdrawal of unused insulation. The result shows that waste to landfill can be reduced by: • Have a sustainability competence at an early stage • Educate employees • Use a good waste management system • Try to sort as much as possible and avoid fraction mixed waste • Take advantage of the suppliers' take-back service.
202

Tratamento de lixiviado de aterro sanitário por um sistema composto por filtros anaeróbios seguidos de banhados construídos: estudo de caso - Central de Resíduos do Recreio, em Minas do Leão/RS / Sanitary landfill leachate treatment for a system composed by upflow anaerobic filters followed by constructed wetlands: case study - Recreio Central Waste, in Minas do Leão/RS

Bidone, Ricardo Figueira 03 March 2008 (has links)
A presente pesquisa abordou o estudo em escala real do tratamento de lixiviado de aterro sanitário em um sistema composto por dois filtros anaeróbios seguidos de dois banhados construídos. O trabalho foi desenvolvido na estação de tratamento de lixiviado do aterro sanitário pertencente à Central de Resíduos do Recreio, localizada em Minas do Leão/RS. Pretendeu-se verificar a eficiência do sistema na remoção de matéria orgânica e de nitrogênio amoniacal. A fase 1 da pesquisa, que avaliou o desempenho dos filtros anaeróbios quando operados em série, indicou que a quase totalidade da remoção de matéria orgânica facilmente biodegradável ocorreu no primeiro filtro, evidenciando que, para o tratamento do lixiviado em questão, não é interessante a utilização de dois filtros anaeróbios de fluxo ascendente semelhantes em série. A fase 2 avaliou o desempenho dos filtros anaeróbios operados em paralelo e dos banhados construídos. Foi possível concluir-se que: filtros anaeróbios de fluxo ascendente são excelente alternativa para o tratamento de lixiviado de aterro sanitário, pois podem viabilizar remoções de matéria orgânica superiores a 50%; banhados construídos representam uma ecotecnologia interessante para o complemento do tratamento de lixiviado, pois podem viabilizar elevadas remoções de N-amoniacal. / This study discussed the sanitary landfill leachate treatment in a full scale system composed by two upflow anaerobic filters followed by two constructed wetlands. The research was developed at the landfill leachate treatment station owned by Recreio Central Waste, located in Minas do Leão/RS. The objective of the study was to verify the efficiency of the system in the removal of organic matter and ammonia nitrogen. The phase 1 of the study, which evaluated the performance of anaerobic filters when operated in series, indicated that almost all of the removal of organic matter readily biodegradable occurred in the first filter, showing that, for the treatment of leachate concerned, it is not interesting the use of two similar upflow anaerobic filters in series. The phase 2 assessed the performance of the anaerobic filters, operated in parallel, and the constructed wetlands. It could be concluded that: upflow anaerobic filters are excellent alternative for the sanitary landfill leachate treatment, as they may facilitate removal of organic matter greater than 50%; constructed wetlands represent an interesting eco-technology to complement the leachate treatment, which can enable high removals of N-ammonia.
203

Utilização de métodos geoelétricos na caracterização de célula experimental no aterro de resíduos urbanos Delta A em Campinas - SP / Use of geoelectrical methods in the characterization of an experimental cell at the landfill of municipal waste Delta A in Campinas - SP.

Siqueira Neto, Antonio Carlos de 20 March 2015 (has links)
Os métodos de eletrorresistividade (ER) com a técnica de caminhamento elétrico (CE), método da polarização induzida (IP) e o método eletromagnético indutivo (EM) foram aplicados no aterro Delta A, localizado ao lado da rodovia dos Bandeirantes no município de Campinas (SP). Dentro do aterro há uma região de aproximadamente 5.200 m² denominada célula experimental, com impermeabilização de base por meio de geomembrana de PEAD (Polietileno de alta densidade) onde ocorre um monitoramento regular pelo Departamento de Geotecnia da UNICAMP. Esse projeto teve como objetivo principal verificar como o corpo de resíduos e a geomembrana são imageados com os métodos geofísicos, e se existe evidência de zonas de concentração de chorume e como seriam as imagens caso houvesse ruptura da geomembrana com vazamento. Na área foram executadas 6 linhas com extensão de 110 m e espaçamento de 12 m entre elas, utilizando arranjo dipolo-dipolo com espaçamento entre eletrodos de 4 m e 5 m e cabo de 10 e 20 m para as medidas de EM. Com os resultados apresentados podemos afirmar que o método que melhor forneceu informações sobre a célula experimental foi o de eletrorresistividade, pois identificou a camada resistiva (geomembrana) e nos permitiu comparar os dados com as simulações feitas em laboratório. No entanto, para uma melhor resolução dos dados de ER se faz necessário diminuir a distância entre os eletrodos, aumentando assim a acurácia do levantamento. / The methods of resistivity (ER) with the electrical profiling technique (EP), the method of induced polarization (IP) and the inductive electromagnetic method (EM) were applied to landfill Delta A, located next to the highway dos Bandeirantes in Campinas (SP). Within the landfill there is a region of approximately 5,200 m² called \"experimental cell\" with waterproofing base through HDPE (High Density Polyethylene) geomembrane which is regular monitoring by the UNICAMP Geotechnical Department. The main objective was to verify how the body of waste and the geomembrane are imaged with geophysical methods, and if there is evidence of leachate concentration areas and how the images would be if there was rupture of the geomembrane leaking. In the area were performed 6 lines with a length of 110 m and 12 m spacing between them using dipole-dipole array with electrode spacing of 4 m and 5 m and cable of 10 and 20 m for EM measures. With the results presented we can say that the method that best provided information on the experimental cell was the resistivity method, as identified resistive layer (geomembrane) and allowed us to compare the data with simulations in the laboratory. However, for better resolution of the ER data is needed to close the distance between the electrodes, thereby increasing the accuracy of the survey.
204

Remoção de matéria orgânica e nitrogênio de lixiviados de aterro sanitário: tratamento por nitritação/desnitritação biológica e processos físico-químicos. / Removal of organic matter and nitrogen from landfill leachate: treatment by nitritation/denitritation biological and physico-chemical processes.

Yabroudi Bayram, Suher Carolina 13 November 2012 (has links)
A presente pesquisa objetivou estudar a remoção de matéria orgânica e nitrogênio de lixiviados de aterro sanitário, através do processo biológico de nitritação/desnitritação, operando um reator de lodos ativados em bateladas sequenciais e pós-tratamento físico químico. O trabalho foi dividido em cinco etapas. Durante a primeira, buscou-se ajustar a duração das etapas anóxica e aerada e as condições operacionais, assim como avaliar a utilização da matéria orgânica presente no lixiviado como fonte de carbono. Ao longo de 16 ciclos de tratamento, os resultados da etapa anóxica indicaram que a duração desta não deveria ser maior que uma hora. A desnitritação ficou limitada ao baixo conteúdo de matéria orgânica de fácil biodegradação no lixiviado, o que levou a baixas taxas, entre 0,010 e 0,142 kg.N-NO2-/ m³.dia. Na segunda etapa, foi ajustada a duração da reação anóxica em uma hora, registrando taxa de desnitritação volumétrica média de 1,704 kg.N-NO2-/ m³.dia, assim como remoção de 80% da DBO e 47% de COT, o que indica que a maior parte da matéria orgânica biodegradável foi empregada pelos micro-organismos heterotróficos na desnitritação. Ao final da fase aeróbia, ao longo da primeira e segunda etapa, mantendo uma concentração de oxigênio dissolvido na massa de líquido do reator de 2,0 mg.O2/L, foi possível alcançar eficiências de remoção de N-NH3 de 98% com predominância do N-NO2-, evidenciado pela relação N-NO2-/(N-NO2-+ N-NO3-) próximo de 1. As taxas volumétrias de nitritação variaram na faixa de 0,095 e 0,199 kg.N-NH3/m³.dia. Como o sobrenadante do reator principal apresentava concentrações elevadas de N-NO2- ao final da fase aeróbia, o efluente foi aplicado em um reator de polimento adicionou-se etanol como fonte de carbono. O tratamento complementar ocorreu sem desequilíbrios, apesar do prolongado tempo de reação anóxica requerido para reduzir toda a massa de nitrito introduzida no sistema, fato que levou a registrar baixas taxas de desnitritação, entre 0,221 e 0,052 kg N-NO2-/kg SSV.dia. Durante a quarta etapa, foi avaliado em um segundo reator de lodo ativado em bateladas sequenciais o processo de nitritação/desnitritação, adicionando dentro do reator, ao início da fase anóxica, o etanol para a redução biológica de todo o nitrogênio oxidado a nitrogênio gasoso. Com concentrações de OD no conteúdo do reator de 2,0 mg.O2/L e valores de pH de 8,27±0,27, a relação N-NO2-/(N-NO2- + N-NO3-) não foi superior a 70% nos 9 ciclos estudados, indicando a presença de nitrato. A hipótese que melhor explica a situação refere-se à possibilidade de que a biomassa esteja se adaptando as novas condições operacionais e a probabilidade de que a adição do etanol durante a reação anóxica possa estar criando condições que favorecem a atividade das bactérias oxidantes de nitrito, assim como os menores diâmetros de floco. A quinta etapa compreendeu a aplicação de um pós-tratamento com redução do pH, adição de sais de ferro e carvão ativado em pó (CAP). Nestes testes, foram registradas remoções de COT e cor de de 93% e 98% respectivamente, mantendo pH em 3,0 e dosagens de 300 mg.Fe+³/L e 15 g.CAP/L. / This research aimed to study the removal of organic matter and nitrogen from landfill leachate through biological process of nitritation/denitritation, operating an activated sludge reactor in sequential batches, and physical- chemical post treatment. The work was divided into five stages. During the first stage, was tried to adjust the duration of the anoxic and aerated stages and operational conditions, and evaluate the use of organic matter present in the leachate as a carbon source. Over 16 cycles of treatment, the results of the anoxic stage indicated that this duration should not be greater than one hour. The denitritation was limited by the low organic matter rapidly biodegradable content into the leachate, which led to low rates between 0.010 and 0.142 kg.N-NO2-/ m³.day. During the second stage, was adjusted the duration of the anoxic reaction to one hour, and showed medium volumetric denitritation rate of 1.704 kg.N-NO2-/m³.day, as well as removal of 80% of BOD and 47% of TOC. These results indicate, most of the biodegradable organic matter was used for heterotrophic microorganisms for denitritation. At the end of aerobic phase, during the first and second stage, and maintaining a concentration of oxygen dissolved into the liquid mass of the reactor in 2.0 mg.O2/L, it was possible to achieve removal efficiencies of NH3-N to 98% with predominance of N-NO2- , that was evidenced by the ratio N-NO2-/(N-NO2-+ N-NO3-) close to 1. The volumetric nitritation rates varied from 0,095 to 0,199 kg.N-NH3/m³.day. The effluent from the principal reactor contained high concentrations of N-NO2- at the end of the aerobic phase, for that reason it was applied a polishing stage where was added ethanol as a carbon source. Complementary treatment transcurred without problems, just was required a prolonged anoxic reaction to reduce the entire mass of nitrite introduced into the system, fact that lead to register low rates of denitritation, between 0.221 and 0.052 kg N-NO2-/kg SSV.day. During the fourth stage, was evaluated in a second activated sludge sequential batch reactor; the nitritation/desnitritation process added ethanol inside the reactor, at the beginning of the anoxic phase, for the biological reduction from nitrogen oxidized to nitrogen gaseous. Maintained OD concentrations into the reactor of 2,0 mg.O2/L and pH values of 8.27± 0.27, the N-NO2-/(N-NO2- + N-NO3-) ratio was not higher than 70% during the 9 cycles studied, indicating the presence of nitrate. The best hypothesis which explains this situation, related to the possibility of the biomass was adapted to the new operating conditions, and the possibility to addition ethanol at the begging of anoxic reaction, may be created adequate conditions for oxidizer nitrite bacteria, as well as the small floc diameters. The fifth stage consisted to apply a physical-chemical post-treatment with pH and addition of iron salts and powdered activated carbon (PAC). During these tests, was removal 93% and 98% of TOC and color respectively, with pH to 3,0 and doses of 300 mg.Fe+³/L and 15 g.PAC/L.
205

Estudo sobre aproveitamento de resíduos sólidos dispostos em aterros sanitários visando seu aproveitamento energético / Preliminary evaluation of the solid waste disposal in landfill vising the energetic utilization

Oliveira, Margareth de Cássia 02 April 2004 (has links)
Equacionar a problemática do aumento da geração de resíduos sólidos é tarefa complexa, que envolve entre outras, questões de ordem ambiental, de saúde pública e econômica. Quando se trata de disposição final de resíduos sólidos, o aterro sanitário é a única técnica utilizada ambientalmente correta, porém ainda são poucas as cidades que a emprega. Espera-se que nos próximos anos, aumente o número de municípios com aterro sanitário e deste modo, surge um outro problema de cunho ambiental, e em nível mais global, que se refere aos gases liberados pelos aterros sanitários, durante a decomposição anaeróbia da parte orgânica dos resíduos. Estão entre estes gases, o dióxido de carbono e o metano, que contribuem para o efeito estufa. Se por um lado o metano é prejudicial, quando se trata de efeito estufa, por outro lado, pode ser utilizado para fins energéticos como fonte de energia renovável e justamente substituindo os combustíveis fósseis, que representam a maior fonte dos chamados gases de efeito estufa. O presente trabalho, tem como objetivo inicial, levantar as alternativas para o uso de gases de aterro sanitário como fonte de energia, em um segundo momento do trabalho, relacionar as fases da digestão anaeróbia com a produção de metano, através da análise de amostras coletadas em diferentes pontos e profundidades do aterro do município de Piracicaba/SP. / Finding a solution to the problematic of increasing of solid waste is a complex task, which compromises several questions, of order environmental, public health and economic. Referring to the final disposal of solid waste, the landfill is the only right environmenty way use it. Some years from now, is expected a municipality number increasing with landfill and like that, there will be another environmental problem, and more world wide, because the release gases by landfills, during the anaerobic digestion there are. Among these gases carbon dioxide and methane, that contribute to the greenhouse effect. The methane is prejudicial, but on the other hand, it can be used to energetic purpose as renovable energy source in order to substitute fossil fuel. Those are the largest source of greenhouse gas. The goal of this research is to realize a bibliographical study about projects in using landfill gas as energy. Another purpose of it, is to relate the fases of the biodegradability with methane production, using as case study the landfill Pau Queimado (burned wood), located in Piracicaba/SP. According to the result of this research look forward to contributing with dates that can help to evaluate the use of methane as renovable energy source, and as a consequence, reducing the greenhouse effect.
206

Subsídios para a ponderação de fatores ambientais na localização de aterros de resíduos sólidos, utilizando o Sistema de Informações Geográficas / Subsidies for determining the weights of environmental factors for landfill siting using geographic information systems

Pfeiffer, Simone Costa 20 April 2001 (has links)
No presente trabalho foi realizado um levantamento bibliográfico sobre os critérios, fatores e ponderações envolvidos em processos de localização de aterros de resíduos sólidos. Com base nesse levantamento, foram identificados os principais elementos de avaliação envolvidos no contexto decisório em questão e estabelecida a importância relativa através de cada descritor em questão através de ponderação dos mesmos. Estes dados foram aplicados em um estudo de caso (em torno de Ribeirão Preto - SP) visando a seleção preliminar de áreas adequadas à disposição de resíduos sólidos utilizando-se o sistema de informações geográficas (SIG). Este estudo teve como objetivo principal discutir os dados obtidos. Para a seleção de áreas com viabilidade ambiental foram utilizados três diferentes métodos - lógica boleana, ponderação dos fatores e fuzzy - que resultaram na exclusão de 96,2% e 13,8%, respectivamente, da área estudada. / Sanitary landfilling is the conventional method of disposing of municipal solid waste. Thus, the focus of the work was to develop the data and tool necessary to aid decision makers and special interest groups begin to understand the alternatives and tradeoffs in the landfill siting process. A Geographic Information System (GIS) were used to determine suitable areas for solid waste landfill sites in Ribeirão Preto (SP). The siting criteria for selecting a potencial site include geological and hydrogeological conditions, surface water distances, buffer zone of roads, topography, soil, land use and proximity to centres of population. The weights or \"importance\" these criteria have a huge bearing on the decision making process. In spatial siting analysis with multiple factors, balancing the relative importance of varied factors can be difficult. Thus, a set of weights for the factors was presented and discussed.
207

Estudo dos lixiviados das frações do aterro sanitário de São Carlos - SP por meio da caracterização físico-química / Study from de leachate of fractions from São Carlos landfill - SP through the physicochemical characterization

Ferreira, Adriana Gonçalves 14 May 2010 (has links)
Este trabalho teve como objetivo determinar as fases de decomposição das frações dos resíduos dispostos no aterro sanitário de São Carlos - SP a partir do estudo das características dos lixiviados gerados. Foram coletadas amostras do lixiviado gerado na parte mais antiga do aterro (encerrada a 10 anos) e nas 1ª, 2ª e 3ª ampliações (esta última em operação). A coleta foi dividida em dois períodos: seco (junho a setembro de 2009) e chuvoso (outubro a dezembro de 2009). As seguintes análises foram realizadas: pH, alcalinidade, ácidos voláteis totais, DQO, sólidos, metais, NTK e \'N\' amoniacal. Em todos pontos os valores de pH encontrados foram superiores a 8. A alcalinidade variou entre 4000 e 12000 mg/L \'CA\'\'CO IND.3\' enquanto os AVT apresentaram concentrações sempre inferiores a 700 mg/L \'CA\'\'CO IND.3\'. A DQO apresentou concentrações entre 3000 e 7000 mg/L durante o período seco, decaindo para 2000 e 4000 mg/L no período chuvoso. Os resultados encontrados sugerem que o lixiviado de todos os pontos encontram-se na fase metanogênica de decomposição da matéria orgânica. A partir dos resultados de NTK e \'N\' amoniacal ficou evidente que a amônia é o poluente presente em maior concentração no lixiviado - corresponde a mais de 70% do NTK. A biodegradabilidade foi investigada através das relações AVT/DQO e STV/ST e resultaram em valores menores que 0,25 e 0,3 respectivamente, indicando que o lixiviado do aterro de São Carlos possui baixa biodegradabilidade. / This work aimed to determine the stages of the decomposition of the waste disposed in São Carlos - SP landfill fractions through the study of the characteristics of the generated leachate. Samples were collected from the older area of the landfill (closed 10 years ago), and also from the first, second and third new built areas (garbage is still being dumped in the third one). The samples were collected in two periods: the dry one (from June to September 2009) and the rainy one (from October to December 2009). The concentration of pH, alkalinity, total volatile acids, COD, solids, metals, sodium and potassium, total nitrogen and ammonium-\'N\' were determined in the study. In all the points sampled the values of pH were higher than 8. The alkalinity ranged from 4000 mg/L to 12000 mg/L \'CA\'\'CO IND.3\', while the total volatile acids concentrations were less than 700 mg/L \'CA\'\'CO IND.3\'. The COD present concentrations between 3000 e 7000 mg/L in the dry period decaying to 2000 and 4000 mg/L in the rainy period. The results found suggest that all the leachate analyzed is in the methanogenic phase of the organic matter. From the total nitrogen and ammonium \'N\' results it turned out to be evident that ammonia is the major pollutant present in the leachate - more than 70% of the total nitrogen. The biodegradability was investigated through the relations VFA/COD and VS/TS and resulted in values lower than 0,25 and 0,3 respectively, indicating that the leachate from São Carlos landfill has low biodegradability.
208

Comportamento hidráulico de alguns solos lateríticos para uso como barreira impermeável

Macambira, Indira Queiroz 09 August 2002 (has links)
Barreiras impermeáveis são uma necessidade em várias obras de engenharia e, em geral, naquelas destinadas à disposição de resíduos, como os aterros e as lagoas de efluentes. Solos compactados têm sido largamente utilizados para essa finalidade. Nesse sentido, esses solos devem ter características apropriadas, como baixa permeabilidade, as quais devem permanecer frente às solicitações de obra. Este trabalho trata do estudo da potencialidade do uso de solos lateríticos compactados em barreiras impermeáveis para sistemas de contenção de resíduos. Neste estudo avaliaram-se os efeitos da umidade e da energia de compactação em duas propriedades importantes para a finalidade desejada, a permeabilidade e a contração, por meio de corpos de prova de dimensões reduzidas, tal qual utilizado na metodologia MCT. Verificou-se que, em geral, a condutividade hidráulica diminuiu com o aumento da umidade, até a umidade ótima, permanecendo praticamente constante ou diminuindo ligeiramente a partir daí. O aumento da energia de compactação diminuiu as condutividades hidráulicas de forma pronunciada no ramo seco da curva de compactação, mas após a umidade ótima as variações foram pequenas para energias acima de 12 golpes. As mínimas condutividades hidráulicas obtidas foram da ordem de '10 POT.-7' cm/s para vários solos ensaiados. Outro fator que também influenciou na diminuição da condutividade hidráulica dos solos foi o aumento da porcentagem de argila. No que se refere às contrações dos solos, o aumento da umidade acarretou em aumento das contrações axiais, que atingiram valores máximos da ordem de 4%. Os solos mais arenosos apresentaram as menores contrações axiais, não ultrapassando valores da ordem de 1%, enquanto para os solos argilosos as contrações médias foram da ordem de 2%. O aumento da energia de compactação acarretou ligeiro aumento das contrações axiais / Impermeable barriers are a need in several engineering works, specially in waste containment systems and effluents ponds. Compacted soils have been used for that purpose. In that sense, the candidate soils should have appropriate characteristics, such as low permeability, which must remain throughout the design life. This work deals with the potentiality of using lateritic compacted soils in impermeable barriers for waste containment systems. In this study the influence of the water content and the compacting energy on the permeability and on the shrinkage of those soils was studied, through specimens of reduced dimensions, as used in the MCT methodology. It was verified that, in general, the hydraulic conductivity decreased with the increase of the water content, until the optimum water content, staying practically constant since then. The increase of the compacting energy reduced the hydraulic conductivities in the dry side of the compacting curve, but beyond the optimum water content the variations were small for energies larger than 12 blows. The lower hydraulic conductivities obtained were of the order of '10 POT.-7' cm/s for several soils. Hydraulic conductivity was also reduced with the increase of the clay percentage. Regarding soil shrinkage the increase of the water content caused an increase on the axial shrinkage that reached maximum values in the order of 4%. The sandy soils presented the smallest axial shrinkage (lower than 1%), while for the clayey soils the average shrinkage reached about 2%. The increase of the compacting effort caused a little increase of the axial shrinkage
209

Avaliação de áreas para disposição de resíduos: proposta de planilha para gerenciamento ambiental aplicado a aterro sanitário industrial / Site assessment for waste disposal: the proposition of a spreadsheet for environmental management applied to sanitary industrial landfills

Kataoka, Sergio Massaru 24 April 2000 (has links)
Esta dissertação apresenta uma revisão dos principais estudos relacionados à disposição final de resíduos sólidos das mais variadas origens em aterros sanitários ou aterros sanitários industriais. Considerando-se estes estudos, foi e laborada uma planilha para avaliação e gerenciamento ambiental de um aterro sanitário industrial, abordando os principais elementos necessários à caracterização do meio físico, biológico, sacio-econômico, além da avaliação dos critérios de projeto, classificação dos resíduos e programas de monitoramento e controle ambiental. As planilhas foram aplicadas na avaliação dos estudos de impacto ambiental EIA/relatório de impacto ambiental RIMA de 3 aterros sanitários industriais. O critério de avaliação foi baseado no atendimento aos itens da planilha adotando-se um sistema de pontuação para análise final dos estudos. A avaliação final mostrou as deficiências dos estudos apresentados nos EIA/RIMA elaborados para a obtenção do licenciamento ambiental e aprovação das áreas para instalação dos empreendimentos. / This dissertation presents a revision of the current researches on solid waste disposal, that comes from a great variety of domestic waste or industrial waste landfills. Concerning to this research, it was proposed a spreadsheet for environmental assessment and management of sanitary industrial landfills, comprising the most important features for the global environment, besides the evaluation of project criteria, waste classification, monitoring programs and environmental control. This spreadsheet have been applied to evaluate the environmental impact assessment (EIA) of three sanitary industrial landfills. The assessment criteria were based on ranking the elements that attend the spreadsheet items. As final results, it can be demonstrated the deficiencies of the current ElA studies that have been proposed for obtaining environmental licenses and permissions to sites for enterprising purposes.
210

Desempenho de camadas de proteção para geomembranas / Performance of protective layers for geomembranes

Geroto, Regis Eduardo 17 October 2008 (has links)
A eficiência das geomembranas como barreiras para controle e desvio de fluxo está diretamente relacionada com a integridade de sua superfície. Nos sistemas de impermeabilização basal, como utilizados em aterros sanitários, as geomembranas podem entrar em contato com materiais perfurantes e cortantes, como a brita do sistema de drenagem. Para prevenir perfurações e outros danos em geomembranas, são empregadas camadas de proteção, como geotêxteis não-tecidos e areia. Este estudo avalia o desempenho de geotêxteis não-tecidos de fibras curtas de poliéster (PET) e de polipropileno (PP), além de uma configuração com areia, como camadas de proteção para geomembranas de policloreto de vinila (PVC) e de polietileno de alta densidade (PEAD). Foram realizados ensaios índices, ensaios de puncionamento hidrostático e ensaios de carregamento estático em grande escala, para verificar os mecanismos de ruptura das geomembranas e o comportamento da resistência ao puncionamento com a adoção de camadas de proteção. Os resultados demonstraram desempenho superior, como elemento de proteção, dos geotêxteis de maior resistência mecânica e mecanismos de rupturas diferenciados entre geomembranas de PEAD e de PVC. / The efficiency of geomembranes as barriers for flow diversion is directly related to its integrity. In basal lining systems, such as those used in landfills and waste disposal lagoon, geomembranes can get into contact with sharp materials, such as gravel from the drainage system, which can induce excessive deformation and holes. To prevent geomembrane damage, nonwoven geotextiles and sand are usually employed as protective layers. This paper deals with the performance of polyester (PET) and polypropylene (PP) nonwoven geotextiles and a sand layer, as protective layers for polyvinyl chloride (PVC) and high density polyethylene (HDPE) geomembranes. Index, hydrostatic puncture and large-scale uniaxial compression tests were performed and have allowed understanding the geomembrane damage mechanism and the influence of protective layers properties in increasing the geomembrane performance against puncture. The test results have shown that the behavior in puncture protection is related to the mechanical resistance of geotextile and that the rupture mechanism is different for the different types of geomembrane used in the study.

Page generated in 0.0552 seconds