• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 80
  • 30
  • 3
  • 2
  • 2
  • 1
  • Tagged with
  • 129
  • 50
  • 41
  • 33
  • 30
  • 15
  • 14
  • 14
  • 13
  • 13
  • 13
  • 12
  • 12
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Solução efervescente para higiene de próteses totais: influência na sorção de água, solubilidade, dureza e na alteração de cor de reembasadores / Effervescent solutions for denture hygiene: Influence in water sorption, solubility, hardness and color changes of denture liners

Antonio de Luna Malheiros Segundo 18 December 2007 (has links)
Este estudo avaliou propriedades físicas de materiais reembasadores para dentaduras após imersão em solução à base de perborato de sódio. Em todos os testes, os materiais, Kooliner e Elite Soft foram divididos nos grupos G1 (controle): imersão em saliva artificial a 37°C e G2 (experimental): imersões diárias em solução à base de perborato de sódio (Corega Tabs) por 5 minutos. Para os testes de sorção, solubilidade, alteração de cor e de dureza, foram obtidos 30 espécimes em forma de disco (15x3mm) de cada material, por meio da técnica direta, a partir da prensagem do material em matriz metálica vazada entre duas placas de vidro. A sorção e solubilidade foram avaliadas após 120 dias de imersão. A alteração de cor foi avaliada imediatamente após o acabamento dos corpos-de-prova e após 30 e 120 dias. A dureza dos materiais foi mensurada inicialmente, após 30 e 60 dias de imersão. O teste de Kruskal-Wallis (P<0,05) indicou que para o material Kooliner, o tipo de imersão (G1=1,43; G2=1,63) não interferiu nos valores de sorção. Quanto ao Elite soft, o perborato de sódio (G1=0,29; G2=0,51) promoveu aumento significativo nos valores de sorção. Comparando os materiais, o Kooliner apresentou médias de sorção significativamente mais altas que o Elite soft, para os dois grupos estudados. Para solubilidade, o teste Anova (P<0,05) a dois fatores de variação indicou diferença significante entre o fator grupo e entre o fator material. O Kooliner (0,168) bem como o grupo 1(0,137) apresentaram as maiores médias de solubilidade em relação ao Elite soft (0,089) e o grupo 2 , respectivamente. Com relação à cor (Anova, P<0,05), os dois materiais sofreram alteração no intervalo de 30 (Kooliner: G1=3,63, G2=2,87; Elite soft: G1=6,27, G2=6,01) e 120 (Kooliner: G1=4,21, G2=3,94; Elite soft: G1=8,54, G2=9,23) dias de imersão. O fator grupo não influenciou nesta propriedade dos materiais. Para a dureza do Kooliner, foi aplicada a análise de variância a dois fatores de variação (grupo: G1=6,63; G2=7,27 e tempo: T0=5,24; T30=7,28; T60=8,34), que indicou diferença somente para o fator tempo. Após a comparação das médias (Tukey=0,87), notou-se aumento significante (P<0,05) da dureza entre todos os tempos avaliados. Os corpos-de-prova de Elite soft do grupo experimental (49,18) apresentaram um aumento (P<0,05) na dureza quando comparado ao grupo controle (48,72). Para o fator tempo, o teste de Tukey (0,76), indicou diferença significante (P<0,05) entre as três médias (T0=46,45; T30=49,63; T60=50,74). O perborato de sódio não influenciou de forma significante nas propriedades avaliadas neste estudo. Dentre os materiais, o Kooliner foi o que apresentou maior estabilidade, porém é um material com características diferentes do Elite soft. O tempo é um fator importantíssimo na alteração das propriedades dos materiais, tendo interferido em todas as variáveis testadas. Estudos com o objetivo de aprimorar as características dos materiais para uma aplicação a longo prazo devem ser ainda realizados, visando a viabilidade de uso dos materiais reembasadores. / The aim of this study was to evaluate the physical properties of denture liners after immersion in a sodium perborate´s solution. In all the tests, both materials, Kooliner and Elite soft, were divided into the groups G1 (control): immersion in artificial saliva at 37°C and G2 (experimental): daily immersions in a sodium perborates´s solution (Corega Tabs) for five minutes. Thirty specimens (diameter of 15 mm and thickness of 3 mm) were obtained for the tests of water sorption, solubility, color change and hardness. Each material was processed according to the manufacturer´s directions in metallic moulds prepared for this purpose and compressed by two glass plates. Water sorption and solubility were evaluated after 120 of immersion. Color change was evaluated after specimens´ finishing, after thirty and sixty days of immersion. Kruskal Wallis (P<0,05) indicated that the immersion in sodium perborate (G1=1,43; G2=1,63) did not interfere in the water sorption values. Sodium perborate promoted significative raise in the Elite soft´s water sorption (G1=0,29; G2=0,51). Comparing the materials, Kooliner had the biggest means in both groups. In the solubility test, ANOVA (P<0,05), using two variation factors, indicated signifficant difference between groups and materials. Kooliner (0,168) and Group 1 (0,137) presented the biggest solubility means when compared with Elite soft (0,089) and Group 2 (0,110). Both materials changed between 30 (Kooliner: G1=3,63, G2=2,87; Elite soft: G1=6,27, G2=6,01) and 120 (Kooliner: G1=4,21, G2=3,94; Elite soft: G1=8,54, G2=9,23) days of immersion in the color test (Anova, P<0,05). To the Kooliner´s hardness, the ANOVA with two variation factors, indicated signifficant differece only for the time of immersion (grupo: G1=6,63; G2=7,27 e tempo: T0=5,24; T30=7,28; T60=8,34). Comparing the means (Tukey=0,87) a signifficant raise (P<0,05) of the hardness was observed between all the periods evaluated. Specimens of the experimental group of Elite soft (49,18) showed a raise (P<0,05) in the hardness when compared to the control group (48,72). The test of Tukey (0,76) indicated significant difference (P<0,05) in the time of immersion between the three means (T0=46,45; T30=49,63; T60=50,74). Sodium perborate did not influence significantly the properties evaluated in this study. Between the materials, Kooliner presented the best stability. But both materials have different compositions and behave in different ways clinically. The period of immersion is a very important factor in the physical properties of the materials; and all of them presented signifficant differences during this period. Studies with the intention of improving the materials´ properties for a long term use should be tried to make viable the use of denture liners.
72

Avaliação clínica e laboratorial de uma solução experimental para higiene de reembasador resiliente para prótese total / Clinical and laboratory evaluation of an experimental solution for hygiene of denture soft liners

Antonio de Luna Malheiros Segundo 17 May 2011 (has links)
Este estudo avaliou a eficácia de métodos de higiene na remoção do biofilme da prótese total inferior reembasada com reembasador resiliente à base de silicone. Trinta pacientes tiveram suas próteses inferiores reembasadas (Mucopren soft) e, aleatoriamente, foram distribuídos em três grupos: A) Método mecânico escovação com dentifrício (Corega Brite) e escova (Johnson & Johnson) específicos para prótese total; B) Método químico imersão em solução à base de Ricinus communis; C) Método associado associação A+B. O período experimental foi de 60 dias e para a quantificação do biofilme, a superfície interna da prótese total inferior foi evidenciada (Fluoresceína sódica 1%) e fotografada, após 15, 30 e 60 dias de utilização dos métodos. As áreas, total da prótese e a corada (biofilme), foram mensuradas com o software Image Tool 3.0 e os resultados expressos em porcentagem. A análise microbiológica foi realizada pela técnica de hibridização DNA-DNA checkerboard. Para a avaliação qualitativa do material reembasador, às próteses foram atribuídos escores (0, 1 e 2) em função da apresentação do material após os períodos avaliados. Os testes estatístico iniciais indicaram a distribuição não normal ou homogênea dos dados, optando-se pela transformação dos mesmos em raiz quadrada de forma a aplicar estatística paramétrica. Quanto a quantificação do biofilme, empregou-se o teste Anova seguido pelo teste complementar de Tukey considerando P<0,05. Houve diferença significante entre os métodos (P=0,009) e períodos (P=0,003) avaliados. Não houve interação entre os fatores (P=0,5). O método mecânico apresentou a menor média de porcentagem de biofilme (1,45±1,03) se comparado ao químico (2,96±1,98) e associado (2,71±1,76). Após 60 dias (3,37±2,04), o acúmulo de biofilme foi maior que após 15 (1,28±0,77) e 30 (2,46±1,54) dias de utilização dos métodos. Para análise da eficácia antimicrobiana, foi empregado o método linear generalizado, não havendo interação entre os tempos e métodos de higiene. Entre estes, das 38 espécies estudadas, em 10 houve diferença estatística para, sendo que o método de imersão apresentou os valores mais baixos de contagem destes microorganismos. Apenas uma espécie apresentou diferença entre os períodos. Após a análise visual, verificou-se que o nível de deterioração foi menor após os 60 dias de análise nos materiais reembasadores higienizados por meio da escovação. As próteses higienizadas pelo método mecânico apresentaram a menor porcentagem de área de biofilme e o menor nível de degradação do reembasador. O método químico apresentou maior eficácia na diminuição de contagem de microorganismos, inclusive nas espécies de Candida. / The aim of this study was to evaluate the effectiveness of hygiene methods on biofilm removal of the lower denture relined with a silicone material. Thirty patients had their lower dentures relined (Mucopren soft) and randomly divided into three groups: A) Mechanical method brushing with toothpaste (Corega Brite) and toothbrush (Johnson) specific for complete dentures; B) Chemical method immersion in Ricinus communis based solution; C) Associate method association of A and B. The experimental period lasted 60 days and for the biofilm quantification, the internal surface of the lower denture was evidenced (Sodium fluorescein 1%) and photographed, after 15, 30 and 60 days of use of the prostheses. Total and evidenced (biofilm) area of the dentures were measured by the software Image Tool 3.0 and the results were expressed in percentages. Microbiological analysis was performed by the DNA-DNA checkerboard technique. For the qualitative evaluation of the soft liner, scores were attributed to the prostheses (0, 1 and 2) according to the presentation of the material after evaluation periods. After verification of distribution and homogeneity of data, it was found that the distribution was not normal or homogeneous, opting for transformation in square root in order to apply parametric statistics. For the biofilm quantification, Anova was employed followed by the Tukeys test considering P<0,05. There were significant difference between the methods (P=0,009) and periods (P=0,003) evaluated. There was no interaction between the factors (P=0,5). Mechanical method presented the lowest mean percentage of biofilm. (1,45±1,03) when compared to the chemical (2,96±1,98) and to the associated method (2,71±1,76). After 60 days (3,37±2,04), the accumulation of biofilm was greater than after 15 (1,28±0,77) and 30 (2,46±1,54) days of the methods use. To analyze the antimicrobial efficacy, the generalized linear method was used. The test showed no interaction between periods and groups. Between groups, 10 of the 38 species evaluated presented statistical difference; and the immersion method showed the lowest counting values of those microorganisms. Only one specie presented statistical difference between the periods. After the visual analysis, it was found that the level of the dentures cleaned by the mechanical method exhibited the lowest percentage of biofilm area and presented the lowest level of degradation of the liner. The chemical method was more efficient in reducing the count of bacteria, including the Candida spp.
73

Estudo do comportamento de liners atacados por ácido sulfúrico / Study of the Behavior of liners attacked by sulphuric acid

Knop, Alexandre January 2007 (has links)
A presente pesquisa teve por objetivo a análise do comportamento de diferentes combinações de liners de um determinado solo com e sem cimentação, submetidos à percolação de líquidos ácidos, com o objetivo de simular o comportamento de campo de liners de aterros especiais, que recebem resíduos à base de pirita. Tal resíduo em contato com água e oxigênio forma solução de ácido sulfúrico. Assim sendo, as pretensões deste trabalho foram a análise do comportamento compressivo de liners formados por um dado tipo de solo compactado, com e sem a adição de cimento, através do emprego de um equipamento de adensamento modificado desenvolvido especialmente para esta pesquisa. Da mesma forma, procedeu-se o estudo dos fenômenos de transporte de contaminantes por meio do liner em estudo, basicamente daqueles que comandam o transporte (difusão, advecção, sorção, retardamento da frente de contaminação e grau de afinidade entre o contaminante e o liner). Ensaios isotrópicos a altas tensões de confinamento também foram realizados a fim de se estudar a possível desestruturação dos liners quando percolados por resíduos ácidos. Os resultados obtidos destacam a desestruturação de amostras naturais do solo estudado quando percolado por rejeitos ácidos, em todas as concentrações estudadas, tanto em ensaios triaxiais isotrópicos quanto em ensaios de carregamento axial com deformações laterais nulas. Conclui-se que as águas ácidas quando percoladas por meio de um solo com presença de finos, tende a proporcionar um efeito de carreamento de partículas, aumentando conseqüentemente a porosidade, fator este que poderia proporcionar a falha operacional de um liner. / The objective of this work is to analyse the behavior of a liner formatted by different combinations of soil and cement, percolated by low pH waters under different hydraulic gradients and concentration of acid in the percolant, aiming to simulate in laboratory what would happen in the field to liners in contact with pyrite wastes, from mineral coal mining. Pyrite wastes in contact with water and oxygen result in sulphuric acid, what makes the objective of this research the study of the compressive behavior of the liner submitted to the percolation of acid waters, by means of a special column equipment developed during this research, which allows applying an axial load to the sample under flux. Also, the variation of the transport of contaminants values were investigated, basically diffusion, advection, sorption, retardation coefficient, distribution coefficient, hydrodynamic dispersion, ground water velocity and hydraulic conductivity). Triaxial Isotropic tests were carried out under high confinant pressures in order to verify the volume changes of the samples due to the low-pH contamination. The results show that liners formatted only by soil had rearrange of their structure due to acid percolations, according to both column and isotropic tests. The value of the hydrodynamic dispersion was considerated being totally dependent on the diffusion, because the hydraulic conductivity of the differente combination was low. The results also show that low-pH percolations make a rearrange of the fine particles into the sample, because after a grain size distribution test, the fine particles from the top of the samples were detected on the bottom of the sample, what increase the porosity on the top of the samples, what could lead the liner to a failure.
74

Efeito de tecnicas de envelhecimento acelerado e aplicação de selante sobre a deformação permanente de reembasadores resilientes permanentes / Effect of accelerated aging and surface sealing on permanent deformation of auto-polymerizing soft liners

Silva, Joaquim Alberto da 15 August 2018 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T15:52:10Z (GMT). No. of bitstreams: 1 Silva_JoaquimAlbertoda_D.pdf: 1108935 bytes, checksum: 15a0a956cee4dcf34973383fda778eb8 (MD5) Previous issue date: 2010 / Resumo: O objetivo neste estudo foi comparar o efeito de dois métodos de envelhecimento acelerado (termociclagem e simulação do intemperismo natural) sobre a propriedade de deformação permanente de dois reembasadores resilientes permanentes usados como forradores de próteses removíveis, um à base de silicone (UP) e outro à base resina acrílica (DF), submetidos ou não à aplicação de selante de superfície. Foram confeccionados 120 corpos-de-prova (12,7 mm de diâmetro, e 19 mm de comprimento), distribuídos aleatoriamente em doze grupos (n=10) e submetidos a envelhecimento acelerado (2.000 ciclos) por meio da termociclagem, ou simulação do intemperismo natural (67 ciclos). Para o ensaio, foi utilizado um aparelho mecânico descrito na especificação no18 da A.D.A., com aplicação de carga compressiva (750 gf) durante 30 segundos. Para comparações do mesmo material com e sem selante e entre os materiais no mesmo intervalo de envelhecimento, foi realizada a análise estatística pelo teste de Mann-Whitney (p=0,05). Os testes de Kruskal-Wallis associado ao método de Dunn foram utilizados para comparação do efeito das técnicas de envelhecimento em cada material (p=0,05). O reembasador à base de silicone apresentou menor deformação permanente que o à base de resina, independente do método de envelhecimento (P<0,05). Foi observado que a aplicação do selante de superfície teve efeito sobre a deformação permanente apenas no grupo do material à base de silicone submetido à termociclagem, e que o envelhecimento acelerado promoveu aumento na deformação permanente apenas para o material à base de resina acrílica. / Abstract: This study was performed in order to compare the effects of two different accelerated aging methods on the property of permanent deformation of two permanent softliners. The softliners selected were an auto-polymerizing acrylic resin based and an auto-polymerizing silicone based. The use of surface sealer was also evaluated on both relining materials. For the permanent deformation test specimens were manufactured with 12.7 mm of diameter and 19 mm length, according to A.D.A. specification number 18. A total of 120 specimens were manufactured, sixty of each relining material. All specimens were randomly distributed into twelve groups (n=10) and later submitted to one of the accelerated aging processes (2000 thermocycling cycles or 67 cycles in an EQUV chamber). The permanent deformation test was performed with a mechanical device described in the specification number 18 of A.D.A. with a compressive load of 750 gf applied during 30 seconds. All data was submitted to statistical analysis. MannWhitney test was performed in order to compare the effect of the surface sealer on each material and to compare the permanent deformation of the materials in the same aging group (p=0.05). Kruskal-Wallis and Dunn tests were performed to compare all aging groups of each material (p=0.05). After analysis of the results it was observed that the silicone based reliner presented lower permanent deformation than the acrylic resin based reliner, regardless of the aging procedure. The surface sealer coating was effective only for the thermocycled silicone group and the accelerated aging processes affected only the permanent deformation of the acrylic resin based material. / Doutorado / Protese Dental / Doutor em Clínica Odontológica
75

Ação do ácido undecilênico liberado por material reembasador sobre os biofilmes de Candida albicans ou Candida glabrata / Effects of undecylenic acid released from denture liner on Candida albicans or Candida glabrata biofilms

Gonçalves, Letícia Machado, 1987- 20 August 2018 (has links)
Orientador: Wander José da Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T13:31:39Z (GMT). No. of bitstreams: 1 Goncalves_LeticiaMachado_M.pdf: 2717766 bytes, checksum: fc9c2fda8a63938d55e0dc22f2155635 (MD5) Previous issue date: 2012 / Resumo: Os materiais reembasadores para próteses dentais removíveis, após a exposição à cavidade bucal, apresentam alterações estruturais que facilitam a colonização por espécies de Candida. Neste contexto, o ácido undecilênico (AUD) tem sido incorporado na formulação deste material na tentativa de reduzir o desenvolvimento de biofilmes fúngicos. No entanto, concentrações de AUD liberadas pelo material reembasador e os efeitos destas sobre o desenvolvimento dos biofilmes de Candida ainda não foram elucidados. Por isso, a proposta deste estudo foi investigar a cinética de liberação do AUD a partir do material reembasador e avaliar o efeito deste sobre o desenvolvimento de biofilmes de C. albicans ou C. glabrata. Inicialmente, simulou-se in vitro a liberação do AUD na cavidade bucal através da imersão de corpos de prova de material reembasador (10 mm x 2 mm) em saliva artificial, sendo o produto da liberação quantificado através de cromatografia gasosa. Em seguida, a suscetibilidade de um isolado de referência e dois isolados clínicos de C. albicans (ATCC 90028, P01 e P34) e C. glabrata (ATCC 2001, P11 e P31) ao AUD foi investigada através da concentração inibitória mínima (CIM), concentração fungicida mínima (CFM) e tempo de morte celular (time-kill). Para avaliar o efeito do AUD sobre os biofilmes de Candida, películas de saliva foram formadas na superfície de corpos de prova de material reembasador contendo AUD (grupo experimental) ou não (controle) e, em seguida, biofilmes dos isolados citados foram formados sobre estas superfícies. Nos períodos de adesão, 24, 48 e 72 h de desenvolvimento dos biofilmes, foram realizadas análises de contagem celular através de diluição decimal seriada; de atividade metabólica através da redução mitocondrial do XTT; de estrutura dos biofilmes através da microscopia confocal a laser; e secreção enzimática de proteinases e fosfolipases através de métodos colorimétricos. Os dados foram submetidos à análise de variância seguida de teste de Tukey com nível de significância de 5%. As concentrações de AUD liberadas pelo material reembasador estavam dentro dos intervalos de CIM e CFM encontrados para todos os isolados avaliados. Pelo teste de time-kill foi possível observar que na CIM, o AUD teve ação fungistática por até 8 horas de exposição, para todos os isolados investigados. A presença de AUD não alterou a contagem celular, atividade metabólica, estrutura dos biofilmes e secreção enzimática nos estágios iniciais de colonização (adesão e 24 h) para ambas as espécies investigadas (p > 0.05). A exposição ao AUD resultou em menor contagem celular (p < 0.05) e atividade metabólica (p = 0.001) para os biofilmes maduros (48 e 72 h) de C. albicans, embora alterações estruturais e de secreção enzimática não foram identificadas (p > 0.05). Em contraste, biofilmes maduros de C. glabrata apresentaram maior quantidade de células (p = 0.004), atividade metabólica (p < 0.001) e secreção de proteinases no grupo experimental (p < 0.001). Considerando as limitações deste estudo, pôde-se concluir que a liberação de AUD pelo material reembasador não evitou a colonização de biofilmes de Candida / Abstract: After exposure to oral cavity, denture liners exhibit structural alterations which facilitate colonization by Candida species. In this context, undecylenic acid (UDA) has been incorporated into denture liner formulation in an attempt to reduce the development of fungal biofilms. However, released concentrations of UDA from denture liner and its effects on Candida biofilms have not yet been elucidated. Therefore, the purpose of this study was to investigate the UDA-released concentrations from denture liner and evaluate its effects on C. albicans or C. glabrata biofilms development. Initially, it was simulated, in vitro, the UDA-releasing at oral cavity by immersing specimens of denture liner (10 mm x 2 mm) in artificial saliva, and the released product was quantified by gas chromatography. Then, susceptibility tests of a reference strain and two clinical isolates of C. albicans (ATCC 90028, P01 and P34) and C. glabrata (ATCC 2001, P11 and P31) for UDA were performed by minimal inhibitory concentration (MIC), minimal fungicidal concentration (MFC) and time-kill assays. For evaluate the effects of UDA-released on Candida biofilms, specimens of denture liner containing UDA (experimental group) or not (control group) were saliva-coated and then, biofilms of mentioned strains were developed on such surfaces. At adhesion phase, 24, 48 and 72 h, developed biofilms had their cells counts analyzed by serial dilution; metabolic activity by XTT reduction assay; biofilm structure by confocal laser microscopy; and enzymatic activity of proteinases and phospholipases by colorimetric methods. Data were subjected by analysis of variance followed by Tukey test with a significance level of 5%. UDA-released concentrations from denture liner were within the ranges of MIC and MFC for all strains evaluated. Time-kill results demonstrated that UDA at MIC had a fungistatic behavior for at least 8 hours of exposition for all strains investigated. The presence of UDA did not alter the cell counting, metabolic activity, biofilm structure and enzymatic secretion in the early stages of colonization (adhesion and 24 h) for both species investigated (p > 0.05). At UDA exposure, mature biofilms (48 and 72 h) of C. albicans presented lower cell counts (p < 0.05) and metabolic activity (p = 0.001), although structural changes and enzymatic secretion were not identified (p > 0.05). In contrast, C. glabrata mature biofilms showed higher cell counts (p = 0.004), metabolic status (p < 0.001) and also high secretion of proteinases in the experimental group (p < 0.001). Within the limitations of this study, it could be concluded that UDA-released from DL did not avoid Candida biofilms colonization / Mestrado / Protese Dental / Mestre em Clínica Odontológica
76

Estudo "in vitro" da resistencia da união entre resina acrilica e materiais reembasadores resilientes submetidos ou não a termociclagem

Sanchez, Jose Luiz Lopes 12 July 1999 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T20:48:57Z (GMT). No. of bitstreams: 1 Sanchez_JoseLuizLopes_M.pdf: 7457590 bytes, checksum: 68530df6a97eededc15c5d1377abc735 (MD5) Previous issue date: 1999 / Resumo: Este trabalho teve como objetivo comparar a resistência da união entre bases resilientes (Dentuflex, Ufi-Gel e Eversoft) e resina acrílica (QC-20), submetidas ou não à termociclagem. Foram utilizadas 60 amostras divididas em 6 grupos de variáveis, com 10 repetições cada. Para a confecção das amostras, foram utilizadas matrizes metálicas incluídas em mufla, cujo molde impresso na silicona de condensação e no gesso foi preenchido com resina acrílica. Após polimerizadas, as amostras foram unidas duas a duas em seu eixo longitudinal por uma base resiliente. Em seguida, metade das amostras foi levada ao termociclador MCT2 AMM Instrumental onde foram realizados 3000 ciclos de 1 minuto em água à 5° C '+ ou -'1° C) e 1 minuto em água a 65° C ( '+ ou -'1°C). A outra metade das amostras foi armazenada em água à 37° C durante 24 horas. Após cada período, as amostras foram submetidas a um tracionamento no equipamento EMIC-DL500MF com velocidade de 5mm/minuto. Os dados obtidos foram submetidos à análise estatística pelo Teste de Tukey, ao nível e 5% de probabilidade e as amostras foram analisadas quanto ao tipo de falha ocorrida. O material Dentuflex apresentou os maiores valores de resistência à tração, independentemente do tratamento recebido, apresentando diferença estatística em relação aos demais materiais. O material Eversoft quando termo ciciado apresentou superioridade estatística em relação ao material Ufi-Gel. Para os materiais Dentuflex e Eversoft, a termociclagem aumentou os valores de resistência à tração, apresentando diferença estatística em relação ao controle, entretanto, para o material Ufi-Gel, o comportamento não foi alterado / Abstract: The purpose of this study was to compare the tensile bond strength between soft-liners (Dentuflex, Ufi-Gel and Eversoft) and the acrylic resin (QC-20), submitted or not to the thermal cycling (of 1 minute in water at 5°C and 1 minute in water at 65°C). Twenty samples were made of each soft-liner. Half of each group received thermal cycling, and the other half, did not. For making the samples, metal matrixes were invested in flasks, the molds was packed with acrylic resin and a spacer was used to divided tbe samples in the middle. After the resin curing, the spacer was taken out and the acrylic resins were joint with soft-liner material. Half of the samples were submitted to 3.000 thermal cycles, and the other half, were not. Afterwards, the samples were submitted to the tensile bond strength test in a universal testing machine (EMIC-DL500MF) with a crosshead speed of 5 mm/min. The results, after Tukey test at 5% of probability, showed that the highest values were obtained to the Dentuflex (3:32 MPa), and the lowest values were observed with Ufi-Gel (0.18 MPa), both when submitted to the thermal cycling. According to the results it was observed that: the Dentuflex material presented the highest values of tensile bond strength, independent of the received treatment, presenting statistical differences related to the Eversoft and Ufi-Gel. The Eversoft material when submitted to the thermal cycling presented values statistically higher than the Ufi Gel. For the Dentuflex and Eversoft materials, the thermal cycling increased the tensile bond strength values presenting statistical differences related to the no cycled, and for the Ufi-Gel the behavior was not altered. / Mestrado / Protese Dental / Mestre em Odontologia
77

The Effect of Thermocycling on the Adhesive Strength of Three Long-Term Resilient Liners to Dental Polymers Used for the Additive, Subtractive and Formative Manufacture of Complete Dentures

Azpiazu Flores , Francisco X. January 2021 (has links)
No description available.
78

Factors Affecting Waste Leachate Generation and Barrier Performance of Landfill Liners / 廃棄物埋立処分場における浸出水の発生特性と遮水工の性能への影響要因の解明

Tang, Qiang 24 September 2013 (has links)
京都大学 / 0048 / 新制・課程博士 / 博士(地球環境学) / 甲第17933号 / 地環博第112号 / 新制||地環||22(附属図書館) / 30753 / 京都大学大学院地球環境学舎環境マネジメント専攻 / (主査)教授 勝見 武, 教授 高岡 昌輝, 准教授 乾 徹 / 学位規則第4条第1項該当 / Doctor of Global Environmental Studies / Kyoto University / DFAM
79

Investigation of Temperature, Solution Strength, and Applied Stress Effects on Cation Exchange Processes in Geosynthetic Clay Liners

Katzenberger, Kurt 01 December 2022 (has links) (PDF)
A laboratory test program was conducted to investigate the effects of temperature, solution strength, and applied stress over increasing conditioning durations on cation exchange processes in sodium bentonite (Na-B) geosynthetic clay liners (GCLs). The test program was intended to determine if the variables of temperature, solution strength, and applied stress had beneficial or detrimental effects on the engineering behavior of Na-B GCLs in municipal solid waste (MSW) landfills and laboratory testing applications. Needlepunched-reinforced, double non-woven Na-B GCL specimens were conditioned in fluids of increasing ionic strength (DI water, 2 mM CaCl2, 50 mM CaCl2, and 200 mM CaCl2 representing control, pore water, mild MSW leachate, and harsh MSW leachate, respectively), temperatures of 5 degrees C, 20 degrees C, 40 degrees C, and 60 degrees C, and overburden stresses (30 kPa and 500 kPa representing stresses experienced by cover and bottom liner systems, respectively) which are all representative of geoenvironmental conditions observed in MSW landfill barrier systems. Cation exchange in the bentonite component of all conditioned Na-B GCL specimens was quantified by measuring the bound cation (BC) complexes and cation exchange capacities (CEC) of the specimens using inductively coupled plasma-optical emission spectroscopy (ICP-OES) analysis and by conducting index tests to determine the dimensional characteristics, swell index, and gravimetric moisture content of the specimens. For zero stress conditions, periodic measurements of electrical conductivity, total dissolved solids, sodium and calcium cation concentration, and temperature of the conditioning fluids were recorded to supplement bound cation complex data. For applied stress conditions, electrical conductivity, total dissolved solids, and temperature of the conditioning fluid were recorded. For zero stress conditions, 152 mm x 152 mm Na-B GCL specimens were conditioned in all conditioning fluids and temperatures over increasing time durations ranging from 4 hours to 32 days. For applied stress conditions, 60-mm-diameter Na-B GCL specimens were conditioned in 50 mM CaCl2 conditioning fluid at all temperatures for 4 to 16 days under the applied overburden stresses of 30 kPa and 500 kPa. Temperature, solution strength, and applied stress were all observed to affect cation exchange in the bentonite component of Na-B GCLs. Cation exchange processes were observed to increase with increasing temperature, increasing solution strength, and decreasing applied overburden stress. The majority of cation exchange processes were observed to occur within 8 to 10 days for specimens conditioned under zero stress. Cation exchange processes were observed to have a higher sensitivity to changes in solution strength (up to 625% increase in the change of Na+ BC from DI water to 200 mM CaCl2) compared to changes in temperature (up to 52% increase in the change of Na+ BC from 5 degrees C to 60 degrees C) in zero stress conditions. Changes in the bound cations of the Na-B GCL specimens over time were not reflected in the periodic electrical conductivity measurements taken of the high strength conditioning fluids. The results of this study can be used for quality assurance evaluations of in-service GCLs using thresholds developed for index properties. From the numerical thresholds determined in this study, hydrated Na-B GCL specimens sampled from the field conditioned under zero stress that exhibit swell indices greater than or equal to approximately 70% of the swell index reported by the manufacturer and gravimetric moisture contents of greater than or equal to approximately 200% will likely exhibit adequate hydraulic barrier performance. Hydrated Na-B GCL specimens sampled from the field conditioned under zero stress that exhibit swell indices of less than or equal to approximately 20% of the swell index reported by the manufacturer and gravimetric moisture contents of less than or equal to approximately 100% will likely exhibit inadequate hydraulic barrier performance. The Na-B GCL component of cover liner systems may be susceptible to high rates of cation exchange due to experiencing low overburden stress and elevated temperatures compared to typical earth temperatures. The Na-B GCL component of bottom liner systems may exhibit low rates of cation exchange due to experiencing high overburden stress and cooler temperatures.
80

Listen and Complete: Understanding One-Liners

McGarry, Theresa 18 October 2016 (has links)
Book Summary: New Ways in Teaching With Music shows how music can be incorporated into your lessons as a way to decrease anxiety, increase motivation and retention, and invigorate both students and teachers. This book is a collection of adaptable lessons that use music as a catalyst for effective, engaging, and enjoyable language learning. 101 activities for students of all skill levels and a companion website with online resources are included. The lessons are broken down by topic including: Reading, Writing, Listening, Speaking, Grammar, Vocabulary, Cultural Exploration, Integrated Skills

Page generated in 0.0472 seconds