461 |
O impacto do aumento da urbanização nos niveis das tensões induzidas por descargas atmosfericas nas proximidades de linhas de transmissão / The impact of urbanization on the distribution of lightning induced voltages on overhead linesZago, Fernando 13 August 2018 (has links)
Orientador: Jose Pissolato Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-13T22:10:32Z (GMT). No. of bitstreams: 1
Zago_Fernando_D.pdf: 3563533 bytes, checksum: 6e24082f3d66f620688c4145ed029895 (MD5)
Previous issue date: 2009 / Resumo: Alguns dos principais danos causados por descargas atmosféricas são de origem indireta, ou seja, originam-se dos campos eletromagnéticos provenientes deste tipo de fenômeno natural resultando em problemas de compatibilidade eletromagnética ou em desafios para os projetistas de sistemas de proteção de surtos e de blindagens contra este tipo de interferência. Este trabalho trata de um destes efeitos indiretos, tensões induzidas em linhas aéreas por descargas atmosféricas próximas, utilizando-se das mais recentes pesquisas na área de campos eletromagnéticos provenientes deste tipo de fenômeno natural. Através de uma rigorosa formulação matemática do canal da descarga atmosférica, assim como, dos campos eletromagnéticos provenientes dele, no caso de conexão direta com o solo ou com um objeto elevado (torre ou prédio aterrados), e da consideração de diferentes expressões para o cálculo do raio de atração dos objetos elevados, foi possível realizar um estudo comparativo dos efeitos da urbanização nas proximidades de uma linha aérea com relação ao aumento ou diminuição dos níveis de tensões e correntes induzidas quando da ocorrência de descargas atmosféricas próximas. Estes efeitos foram analisados através de simulações computacionais considerando variações em diversos parâmetros associados à urbanização, tais como: quantidade de objetos elevados, altura média dos objetos elevados, modelo de raio de atração e densidade de ocupação ou de urbanização. A partir da pesquisa realizada durante este trabalho e do programa computacional desenvolvido, são propostas metodologias para se avaliar as modificações nos padrões de ocorrência dos níveis de tensões induzidas de origem atmosférica em linhas aéreas localizadas em diferentes cenários de ocupação urbana ou nas proximidades de objetos elevados como, por exemplo, torres de telecomunicações. / Abstract: Some of the worst damage caused by lightning is indirect, that is, it is caused by electromagnetic fields radiated from this kind of natural phenomenon resulting in electromagnetic compatibility problems or in challenges for designers of surge protection systems and shields against these interferences. This work considers one of these indirect effects, induced voltages on overhead lines by nearby atmospheric lightning discharges, using some of the most recent research in the area of electromagnetic fields generated by these natural phenomena. Starting from a rigorous mathematical formulation for a lightning channel, as well as for the electromagnetic fields generated by them, for the case of lightning striking the soil directly or an elevated grounded object, it was possible to carry out a comparative study of the urbanization effects close to an overhead line with respect to the increase or decrease of the induced voltages and currents when nearby lightning discharges occur. These effects were analyzed using computational simulations considering variations in some parameters associated with urbanization, such as: number of elevated objects, elevated objects average height, different models for the calculation of attractive radius and occupation or urbanization density. Taking into account the research and the computational program developed in this work, methodologies to evaluate the modifications on the occurrence patterns of lightning induced voltages on overhead lines localized at different urban occupation landscapes or at the vicinity of elevated objects like telecommunication towers, were proposed. / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
|
462 |
Calculo dos parametros de linhas de transmissão trifasicas atraves das tensões e correntes em seus terminais / Calculation of parameters of thress-phase transmission lines through voltages and currents in their terminalsLustosa, Leonardo Silva 14 August 2018 (has links)
Orientadores: Jose Pissolato Filho, Sergio Kurokawa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-14T06:30:33Z (GMT). No. of bitstreams: 1
Lustosa_LeonardoSilva_M.pdf: 1611174 bytes, checksum: 2c164206f95ffdeb84cf75eeff5c9f1b (MD5)
Previous issue date: 2009 / Resumo: O objetivo deste trabalho é calcular os parâmetros longitudinais e transversais de linhas de transmissão trifásica a partir das correntes e tensões nas fases das mesmas. Serão utilizadas equações desenvolvidas no domínio modal considerando as obtenções de correntes e tensões em um terminal da linha enquanto o outro terminal permanece em aberto ou em curto-circuito. Inicialmente é apresentada a teoria básica de linhas de transmissão partindo do pressuposto de que tais linhas são melhores representadas através do modelo de parâmetros distribuídos. Assim através da análise de circuitos elétricos e das leis de Kirchhoff são encontradas as equações diferenciais de segunda ordem de tensão e corrente que caracterizam a linha de transmissão. Em seguida é apresentada a metodologia para cálculo dos parâmetros da linha que utiliza a idéia de impedância equivalente de circuito aberto e curto-circuito quando um dos terminais está em aberto e em curto-circuito respectivamente. Utilizando o Toolbox SimPowerSystem do MatLab são simuladas a obtenção das correntes em linhas de transmissão trifásica de 330 kV, 440 kV e 500 kV, todas com comprimento igual a 500 km. De posse de tais correntes são calculados os parâmetros das linhas de transmissão e comparados com seus valores reais, mostrando a viabilidade da metodologia empregada e que o erro obtido com tal metodologia é menor do que o erro entre os parâmetros reais das linhas após construção e seus parâmetros de projeto existente nos bancos de dados das empresas. / Abstract: The objective of this work is to calculate the longitudinal and transversal transmission line parameters using phase currents and voltages. Developed equations are used, in the modal domain, considering current and voltages found between a line terminal and an open line terminal, and a short-circuit terminal. . Initially, the basic transmission line theory is presented assuming that these lines are best represented by distributed parameters model. Therefore, through the analysis of electric circuits and Kirchhoff's laws , second order differential equations for voltage and current are found, which characterizes the line transmission. Next it is shown the method to calculate the line parameters, which uses the concept of open circuit and short-circuit equivalent impedance when one of the terminals is open or in short-circuited respectively. Using the Toolbox of MatLab, SimPowerSystem, estimated currents are simulated in a three-phase transmission line of 330 kV, 440 kV and 500 kV, all with the length of 500 km. The found values are used to calculate parameters of lines transmission and to compared them with their real values, showing that the calculation is possible and that the error obtained with this method is smaller than an error between the real line parameters after construction and those of existing project in the data base of companies. / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
|
463 |
Analise de sensibilidade de parametros eletricos de linhas de transmissão no dominio da frequencia / Sensitivity analysis of electrical transmission line parameters in frequency domainPinheiro, Michel Gonçalves 17 November 2005 (has links)
Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e Computação / Made available in DSpace on 2018-08-08T12:51:45Z (GMT). No. of bitstreams: 1
Pinheiro_MichelGonA§alves_M.pdf: 1094075 bytes, checksum: 1c9863b695ee82d8312c89c87f94085b (MD5)
Previous issue date: 2005 / Resumo: Este trabalho apresenta uma extensa análise de sensibilidade dos parâmetros elétricos longitudinais e transversais de uma linha de transmissão trifásica em função da freqüência. Uma linha real de 440 kV foi utilizada como base para as análises. Considerando determinadas hipóteses simplificadoras, foram calculados os parâmetros elétricos da linha: resistência, indutância e capacitância no domínio da freqüência. Esses parâmetros foram apresentados em termos das parcelas das matrizes primitivas, das matrizes reduzidas e componentes modais. Na análise de sensibilidade variaram-se as seguintes características da linha: diâmetros dos cabos pára-raios, diâmetros dos condutores fase, altura dos condutores, distância horizontal entre as fases, espaçamento vertical dos sub-condutores dos feixes das fases externas. Para cada variação observou-se o comportamento dos parâmetros elétricos em função da freqüência, em termos das parcelas das matrizes primitivas e em termos dos modos. Também foi observado o fator de aterramento e foram estimados os aumentos de potência natural em função das variações realizadas. As linhas com elevada potência natural (LPNE) foram avaliadas no âmbito da análise efetivada / Abstract: In this work a large sensitivity analysis of longitudinal and transversal electrical parameters of a three-phase transmission line in frequency domain was performed. An actual 440 kV transmission line was used as reference in the analysis. Considering some simplified hypothesis, electrical parameters, as resistance, inductance and capacitance, were evaluated in frequency domain. Those parameters were presented in terms of parcels of primitive matrices and reduced matrices in phase modal domain. An extensive sensitivity analysis was performed and the following line caracteristics were varied: ground wires diameter, phase conductors diameter, height of conductors, horizontal distance among phases and vertical spacing within external phases bending. For each line caracteristic, the performance of electrical parameters in frequency domain, in terms of primitive and modal matrices was observed. Also, it was observed the ground factor and it was estimated the increases on natural power. Using of High Natural Power Lines was studied and related to variations of line geometry / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
|
464 |
ESTUDO TEÓRICO E COMPUTACIONAL DO DESEMPENHO DE LINHAS DE TRANSMISSÃO DE ALTA-TENSÃO NA PRESENÇA DE DESCARGAS ATMOSFÉRICAS / THEORY AND COMPUTATIONAL STUDY OF THE PERFORMANCE OF TRANSMISSION LINES FOR HIGH-VOLTAGE DISCHARGES IN THE PRESENCE OF AIRPinheiro, Fernando Henrique Costa 17 October 2008 (has links)
Made available in DSpace on 2016-08-17T14:53:01Z (GMT). No. of bitstreams: 1
Fernando Henrique Costa Pinheiro.pdf: 2854886 bytes, checksum: a56fe59d5aabb7763901adeb614ad703 (MD5)
Previous issue date: 2008-10-17 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / This work depicts transmission line modeling for lightning strike time domain simulation. It is studied and presented the main mechanisms associated to lightning formation and striking high-voltage transmission lines and wave propagation theory concerned to the hit point. Following, it is presented and analyzed transmission lines, shield wires and tower models available in the used ATPDraw computer program. Finally, a complete model is constructed taking into account a real utility transmission branch (ELETRONORTE-Ma), including transmission lines, respective towers and shield wires, through computational models available in the ATPDraw computer program. Computer simulations are carried out and the final model is tested for different scenarios: a standard lightning striking a transmission tower; a standard lightning striking a transmission tower with lower tower foot resistance; lightning striking transmission tower for different soil conditions (dry and humid); insulation strength analysis taking into account different hit points (middle of a shield wire and at the top of a transmission tower). The results show that the model behaved as expected. / Este trabalho aborda a modelagem de linhas de transmissão para análises e simulações no domínio do tempo de transitórios eletromagnéticos resultantes de descargas atmosféricas incidentes. É estudado e apresentado os principais mecanismos associados à formação das descargas atmosféricas, os aspectos relevantes à incidência de descargas em linhas de transmissão e os seus mecanismos de propagação em relação ao ponto de incidência. Em seguida é apresentado e analisado modelos de linhas de transmissão, cabos pára-raios e de torres disponíveis para uso no programa computacional ATPDraw. Por fim, é elaborado um modelo de um trecho real da ELETRONORTE MA incluindo linha de transmissão, suas torres e seus cabos pára-raios, através de modelos disponíveis na versão usada do programa ATPDraw. São realizadas simulações computacionais, onde o modelo é testado para vários cenários: surto atmosférico na forma de onda padrão incidindo sobre uma torre; surto atmosférico na forma de onda padrão incidindo sobre uma torre com resistência de dispersão reduzida; surtos atmosféricos incidentes sobre torres nos cenários de solos secos e úmidos; e impactos nos isolamentos no meio do vão e em uma torre de um surto atmosférico incidente nos cabos pára-raios. Para todos os testes realizados, a resposta do modelo esteve de acordo com o comportamento esperado.
|
465 |
Efeitos da geometria toroidal na atuação de campos helicoidais ressonantes em Tokamaks / Toroidal geometry effects on the performance of resonant helical fields in TokamaksElton Cesar da Silva 01 March 2001 (has links)
Neste trabalho, consideramos os efeitos de um campo magnético ressonante externo sobre o plasma confinado em um tokamak. Este campo magnético pode ser produzido quer por condutores helicoidais ou por um limitador magnético caótico. O principal propósito desse campo magnético ressonante é criar uma região de linhas de força caóticas na borda da coluna de plasma que pode melhorar o confinamento do plasma. O campo magnético de equilíbrio foi obtido resolvendo-se a equação de GRAD-SHAFRANOV em um sistema de coordenadas intrinsecamente toroidal (as coordenadas polares toroidais). Obtivemos o campo magnético, gerado pelos condutores helicoidais, através da solução explícita da equação de LAPLACE no mesmo sistema de coordenadas. A partir desse campo magnético, tomando o termo de mais baixa ordem, obtivemos analiticamente um mapa estroboscópico simplético para um conjunto de anéis limitadores magnéticos caóticos. Calculamos esse mapa estroboscópico simplético usando uma formulação hamiltoniana e adotando a. ação dos limitadores magnéticos caóticos como uma sequência de pulsos do tipo função delta. Com esse mapa estroboscópico simplético, caracterizamos algumas ilhas magnéticas ressonantes e a transição para um regime de caos global através da superposição das mesmas. Usamos esse mapa estroboscópico simplético para estudar o transporte das linhas de força na borda da coluna de plasma. A perda de linhas de força caóticas, que atingem a parede interna do tokamak, segue uma distribuição de POISSON. Calculamos, ainda, o número médio de voltas, ao redor da câmara de vácuo, necessárias para que uma linha de força caótica atinja a parede da câmara. / In this work, we have considered the effects of an external resonant magnetic field on the plasma confined in a tokamak. This resonant field can be produced by helical windings or by a chaotic magnetic limiter. The main purpose of this resonant magnetic field is to create a region of chaotic field lines at the edge of the plasma that can improve the confinement of the plasma. The equilibrium tokamak field was obtained by solving the GRAD-SHAFRANOV equation in an intrinsically toroidal coordinate system (the toroidal polar coordinates). We have obtained the magnetic field which has been generated by helical windings through an explicit solution of the LAPCACE equation in the same coordinate system. From this magnetic field, taken in its lowest order, we have analytically obtained a sympletic stroboscopic map for a set of chaotic magnetic limiters. We have calculated this sympletic stroboscopic map by using a Hamiltonian formulation and by supposing the action of the chaotic magnetic limiters as a sequence of delta-function pulses. With this sympletic stroboscopic map we have characterized some resonant magnetic islands and the onset of global chaos through their overlap. We have used this sympletic stroboscopic map in order to study the transport of the field lines at the edge of the plasma. The loss of chaotic field lines that reach the inner wall of the tokamak follows a POISSON distribution. We have also calculated the average number of toroidal turns for a chaotic field line to reach the inner wall of the tokamak.
|
466 |
Bifurcação de pontos axiumbílicos e ciclos axiais de superfícies imersas em R4 / Bifurcation of axiumbilic points and axial cycles of surfaces immersed into R4Flausino Lucas Neves Spíndola 06 May 2015 (has links)
O objetivo deste trabalho é descrever a estrutura das linhas axiais principais e médias de imersões de superfícies em R4 na vizinhança de pontos axiumbílicos. Pontos axiumbílicos são aqueles nos quais a elipse de curvatura se degenera em um círculo. Estudamos a perturbação dos ciclos axiais principais, e obtemos resultados sobre a genericidade dos ciclos axiais principais hiperbólicos e semi-hiperbólicos. / The aim of this work is to describe the structure of principal and mean axial lines of immersions of surfaces into R4, close to axiumbilic points. Axiumbilic points are those which the ellipse of curvature denegerate in a circle. We study the perturbation of principal axial cycles, and we obtain results about genericity of hyperbolic and semi-hyperbolic principal axial cycles.
|
467 |
Estimativa de idade através das linhas incrementais de cemento / Age estimation through incremental lines in cementumPaulo Eduardo Miamoto Dias 11 June 2010 (has links)
A estimativa de idade pela contagem das linhas incrementais de cemento (LC) adicionadas à idade média de erupção do dente analisado é um método tido como preciso e confiável por alguns autores, enquanto outros o rejeitam afirmando não haver forte correlação entre idade real e estimada. O objetivo do estudo foi avaliar a técnica descrita e verificar se há influência de patologias bucais na estimativa de idade, analisando-se, além do número de LC, correlação entre espessura de cemento e idade real. Foram preparadas por desgaste 31 lâminas transversais, de aproximadamente 30 m, de 25 dentes recém extraídos. As lâminas foram observadas, fotografadas e medidas em microscopia óptica. As LC das imagens foram realçadas com uso do software Image J 1.43s e as contagens foram feitas por um observador e dois observadores-controle. Houve correlação moderada de 0.58 para toda a amostra, com erro médio de 9,7 anos. Para dentes com alterações periodontais, a correlação foi de 0.03 e erro médio de 22,6 anos. Para dentes sem alterações periodontais, a correlação foi de 0.74 e erro médio de 1,6 anos. A espessura de cemento teve correlação com idade real de 0.69 para toda amostra, 0.25 para dentes com problemas periodontais e 0.75 para dentes sem problemas periodontais. A técnica das LC associada à medição de espessura de cemento mostrou-se confiável para dentes sem patologias periodontais, porém em dentes com patologias periodontais ou histórico/quadro clínico desconhecido, recomenda-se a realização de exames macroscópicos conjuntos para comparação. / Age estimation by counting incremental lines in cementum added to the average age of tooth eruption is considered an accurate and reliable method by some authors, while others reject it stating no strong correlation between estimated and actual age. The aim of this study was to evaluate this technique and check the influence of oral conditions on age estimation by analyzing both the number of cementum lines as well as the correlation between cementum thickness and actual age, on diseased teeth. Thirty one undecalcified ground cross sections of approximately 30 m, from 25 freshly extracted teeth were prepared, observed, photographed and measured. The images were enhanced with the use of software and the counts were made by one observer and two control-observers. There was moderate correlation ((r)=0.58) for the entire sample, with mean error of 9.7 years. For teeth with periodontal pathologies, the correlation was 0.03 with a mean error of 22.6 years. For teeth without periodontal pathologies, the correlation was 0.74 with mean error of 1.6 years. There was correlation of 0.69 between cementum thickness and actual age for the entire sample, 0.25 for teeth with periodontal problems and 0.75 for teeth without periodontal pathologies. The cementum lines technique associated with the measurement of cementum thickness was reliable for teeth without periodontal pathologies, but in periodontally diseased teeth or teeth with unknown history/clinical background, parallel macroscopic examinations should be conducted.
|
468 |
Avaliação do uso de observáveis coletadas com receptores de navegação pessoal para determinação de coordenadas em linhas base curtas / Evaluation of the use of observable collected with receivers, personal navigation coordinates to determine base lines shortCláudio Bielenki Júnior 12 December 2008 (has links)
Nas últimas décadas o uso de equipamentos para posicionamento, principalmente os receptores de navegação pessoal, ganhou relativa importância, e a aquisição desses receptores aumentou consideravelmente. Estes receptores, entretanto, não foram desenvolvidos para trabalhos que exijam acurácia, pois estimam e armazenam as posições com precisão e acurácia da ordem de 03-15 m, com 95% de probabilidade, não armazenam os dados de código e fase e não possuem antenas com centro de fase determinado. Com a disponibilização do protocolo de transmissão dos dados destes receptores, foram desenvolvidos alguns programas para, estando conectados ao receptor por meio de hardware e software, extrair e registrar as observações de navegação (código CA e fase da portadora). Desta forma, o uso de receptores de navegação pessoal para medições de coordenadas com boa acurácia, em linhas base curtas, pode tornar-se uma grande alternativa para área de mensuração com aplicações na Engenharia de Transportes. O alto custo de outras técnicas frente à proposta deste trabalho à uma das grandes dificuldades encontradas para uma maior acurácia nos trabalhos geodésicos aplicados aos transportes. Neste trabalho procurou-se analisar o processamento de dados da fase portadora L1 e código CA, coletados com receptores de navegação pessoal,obtidos por meio de softwares auxiliares, levando-se em consideração a algumas variáveis como a distância entre as estações, o tempo de rastreio, softwares de processamento e diferentes equipamentos. Os resultados obtidos promissores confirmando as vantagens de armazenamento das observáveis dos receptores de navegação pessoal para o seu posterior pré-processamento para a obtenção de coordenadas acuradas em linhas bases curtas. / In recent decades the use of equipment for positioning, particularly the personal navigation receivers gained relative importance, and the acquisition of these receivers has increased considerably. These eceivers, however, were not developed for task that requiring accuracy, because it estimate and store positions with precision and accuracy of the order of 03 to 15 meters, with 95% probability, do not store the code and carrier phase data and have no determined Xntennae center stage. With the provision of the protocol for data transmission of these receivers have been developed some programs and is connected to the receiver by way of hardware and software, extract and record the navigation observable (CA code and carrier phase). Thus, the use of the navigation eceivers staff to measurements of coordinates with good accuracy, based on short baselines, can become a great alternative to main measurement in Transport Engineering applications. The high cost of other technologies front to the proposal in this work is one of the difficulties found for a greater accuracy in the applied transports geodesic works. In this research it is looked to analyze the data processing of the L1 carrying phase and CA code collected with the aid of specific software, taking itself consideration changeable as in the baseline between the stations, the observation time, software and different equipments. The results was promising, confirming the benefits of storage observable from the personal navigation receivers for further post-processing to obtain accurate coordinates in short baselines.
|
469 |
Obtenção dos parâmetros sustentados para modelagem de arco secundário em linha de 500 kV / Stationary parameters for secondary arc modeling in a 500 kV transmission lineGarcia, Athos Póvoa, 1988- 07 March 2014 (has links)
Orientador: Maria Cristina Dias Tavares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-26T08:28:58Z (GMT). No. of bitstreams: 1
Garcia_AthosPovoa_M.pdf: 9594597 bytes, checksum: c99eaf2e0c3c48d6e04df60e99d62937 (MD5)
Previous issue date: 2014 / Resumo: Este trabalho apresenta uma metodologia para a obtenção dos parâmetros sustentados do arco elétrico, especificamente a corrente de condução e a corrente de deslocamento. Os resultados apresentados são provenientes da análise de 410 ensaios realizados em ambiente não confinado de um trecho experimental de linha de transmissão aérea de 500 kV , composta por três torres e dois vãos. Foram analisados diversos níveis de corrente entre 15 Aef e 10 kAef. O método apresentado é baseado na obtenção de um novo elemento para a caracterização do arco elétrico, a capacitância. Verifica-se que existe um atraso da forma de onda da tensão entre os terminais do arco em relação à forma de onda da corrente do arco elétrico próximo ao cruzamento das curvas pelo zero. Este comportamento indica uma resposta a um circuito que não pode ser considerado puramente resistivo, mas sim composto por uma resistência e uma capacitância. Desta forma a contribuição da presente pesquisa consiste na identificação da capacitância do arco elétrico. Os resultados obtidos mostram que a utilização da metodologia desenvolvida é eficaz para a obtenção dos parâmetros sustentados do arco elétrico e que tais parâmetros possuem uma relação de proporcionalidade em relação aos níveis de corrente do arco elétrico / Abstract: This work presents a methodology to obtain the stationary parameters of the electric arc, specifically the conductive current and the displacement current. The results presented are from analysis by 410 assays performed at field tests of a test section of 500 kV transmission line. The section is formed by three transmission towers, one anchor tower positioned between two suspension towers. This work presents the analysis of tests with current levels between 15 Arms and 10 kArms. The presented method is based on obtaining a new element to characterize the arc, the capacitance. It is verified that there is a delay of the waveform of the voltage across the arc terminals relative to the waveform of the current arc near zero crossing. This behavior indicates that the arc can not be considered purely resistive, but instead it has a behavior of a parallel resistance and a capacitance impedance. Therefore the contribution of this research is to identify the capacitance of the electric arc. The results show that the use of the developed methodology is effective for obtaining the stationary parameters of the electric arc and that these parameters have a relationship of proportionality in relation to the arc current range.winz / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
|
470 |
Controle adaptativo para religamento tripolar aplicado a linhas de transmissão com compensação reativa em derivação / Adaptive control for three phase reclosing applied to shunt reactor compensated transmission linesMestas Valero, Patricia 19 August 2018 (has links)
Orientador: Maria Cristina Dias Tavares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-19T10:56:05Z (GMT). No. of bitstreams: 1
MestasValero_Patricia_D.pdf: 4018272 bytes, checksum: 38a65b52b68046f67c3791c9b6ea2f7d (MD5)
Previous issue date: 2011 / Resumo: O presente trabalho descreve um novo método de controle adaptativo para chaveamento sincronizado de disjuntores durante a manobra de religamento tripolar de linhas de transmissão com compensação reativa em derivação. O objetivo principal do método desenvolvido é controlar as sobretensões transitórias e reduzir o tempo morto antes do religamento. Diferentes estratégias para controlar sobretensões decorrentes do religamento tripolar são descritas com a finalidade de diferenciar as vantagens do chaveamento sincronizado. Os benefícios potenciais a serem obtidos a partir do religamento tripolar rápido são expostos. O método de controle adaptativo desenvolvido consiste em identificar com antecedência a região ótima para o religamento, permitindo fechar o disjuntor já no primeiro mínimo do batimento da tensão entre os contatos do disjuntor após o tempo morto de atuação da proteção. Após os testes realizados utilizando um programa para simulação de transitórios eletromagnéticos (PSCAD/EMTDC), o método proposto foi implementado em protótipo (controlador). Este protótipo foi testado utilizando o Simulador Digital em Tempo Real (RTDS). As simulações em tempo real demonstraram a eficiência do método no controle das sobretensões e na redução do tempo morto. Finalmente, o método foi avaliado parametricamente para uma série de condições simuladas, incluindo diferentes níveis de compensação reativa em derivação, a influência da compensação série, a influência da transposição da linha de transmissão e os efeitos da variação do comprimento da linha. Além disto, outras simulações foram realizadas para comparar o desempenho dos métodos de controle existentes e do método proposto / Abstract: The present thesis describes a new adaptive control method for synchronous switching of circuit breakers during three-phase reclosing of shunt compensated transmission lines. The main objective of the developed method is to control the overvoltages and to reduce the dead time prior of reclosing. Several strategies to control overvoltages resulting from three-phase reclosing are described in order to differentiate the benefits of the proposed method. The potential benefits obtained from the developed controlled reclosing method are exposed. The proposed algorithm identified, in advance, the optimal region for reclosing of transmission line, allowing closing the circuit breaker at the first minimum voltage beat across circuit breaker, after protection dead time. After off-line testing using electromagnetic transients simulation program (PSCAD/EMTDC), the proposed method was also implemented in physical hardware. This hardware was then tested on a real-time transients simulator (RTDS). The real time simulations demonstrate the method efficiency to control overvoltages and to reduce the dead time. Finally, the method has been parametrically evaluated for a range of simulated conditions, including different shunt compensation levels, influence of series compensation, influence of transmission line transposition, effect of line lengths. In addition, simulations have been conducted to compare the performance of existing control method and the proposed method / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
|
Page generated in 0.1515 seconds