• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 223
  • 50
  • 19
  • 1
  • Tagged with
  • 291
  • 128
  • 73
  • 70
  • 57
  • 56
  • 42
  • 37
  • 32
  • 31
  • 28
  • 26
  • 25
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Étude expérimentale de l’évaporation à haute température de gouttes de combustible en régime de fortes interactions à l'aide de méthodes optiques / Experimental study at high temperature of the vaporization of fuel droplets in strong interaction thanks to optical techniques

Perrin, Lionel 16 December 2014 (has links)
L’étude des transferts de chaleur et de masse lors de l’évaporation de gouttes en mouvement et en interaction est un domaine complexe à cause des nombreux phénomènes en jeu. Les principaux paramètres influençant l’évaporation ont pu être étudiés indépendamment grâce à l’utilisation de diagnostics optiques de mesure non-intrusifs sur un train de gouttes monodisperse. Une technique basée sur la fluorescence induite par laser (LIF) à deux couleurs a été développée afin d’obtenir la température moyenne de gouttes de combustible mono et multicomposant. Afin de supprimer l'effet optique parasite engendré par des résonances morphologiquement dépendantes, un absorbeur non fluorescent a été ensemencé à faible concentration. L’évolution de la vitesse et de la taille des gouttes ont été investiguées grâce à une technique par ombroscopie quantitative qui permis la mesure très précise des taux d’évaporation. Une enceinte à haute température a été conçue afin de générer des conditions ambiantes maitrisées et propices à la formation d’une forte évaporation. Ainsi, les nombres de Nusselt et Sherwood ont été déterminés expérimentalement pour plusieurs combustibles dans diverses conditions d'injection. L'étude sur différents combustibles et à différentes températures d'injection a confirmé l’influence de la volatilité du combustible sur les transferts. L’influence du nombre de Reynolds a aussi été mise en évidence. L’étude de gouttes multicomposant a permis de montrer différentes phases d’échauffement et d’évaporation lors du temps de transit de la goutte liées aux différences de volatilité des combustibles du mélange. Les effets de différentes compositions ont aussi été investigués / The study of heat and mass transfers during the evaporation of moving and interacting droplets remain a complex field because of the various mechanisms in action. The main parameters influencing the evaporation of droplets have been studied separately thanks to non intrusive optical diagnostics that have been used on a monodisperse droplet stream. A technique based on two colors laser induced fluorescence (LIF) was developed to measure the temperature of mono and multicomponent evaporating fuel droplets. The liquid fuel is seeded by a non-fluorescent absorber to eliminate the effect of morphological dependant resonances. The size evolution was obtained thanks to shadow imaging which allowed precise measurements of evaporation rates. A hot chamber was conceived to create controlled ambient conditions around the droplets. Thereby, the Nusselt and Sherwood numbers, characterizing the heat and mass transfers, were deduced from the experimental data for various experimental conditions. The studies allowed confirming the influence of the volatility of the fuel regarding heat and mass transfers. The results also exhibit an influence of the Reynolds number. Finally, the study of multicomponent droplets had shown different heating and evaporating phases during the droplet transit time. Effects of various compositions have also been investigated
222

Development and study of low noise laser diodes emitting at 894 nm for compact cesium atomic clocks / Développement et étude de diodes laser à faible bruit émettant à 894 nm pour horloges atomiques compactes au Césium

Von Bandel, Nicolas 30 June 2017 (has links)
Ce travail de thèse porte sur la conception, la réalisation et l'étude de sources laser à semi-conducteur de haute cohérence, émettant à 894 nm, pour application aux horloges atomiques Césium compactes pompées optiquement, dans un contexte de développement industriel. Nous nous intéressons plus particulièrement aux lasers à émission par la tranche, dits "Distributed-Feedback" (DFB), pompés électriquement. L'objectif est d'obtenir un laser monomode en fréquence, à faible seuil, à rendement optique élevé et de largeur de raie inférieure à 1 MHz. Nous traitons d'abord de la conception et de la caractérisation au 1er ordre des diodes DFB, jusqu'à leur mise en modules pour horloge, puis nous effectuons une étude approfondie des propriétés physiques de l'émission laser en terme de cohérence temporelle, en introduisant une nouvelle méthode universelle de caractérisation du bruit de fréquence optique. Enfin, nous nous intéressons aux propriétés spectrales de l'émission en configuration d'asservissement sur une raie de fluorescence du Césium ("Dither-Locking"). Nous montrons que les propriétés intrinsèques du composant satisfont aux exigences du système industriel tel qu'il a été défini lors de l'étude. / This PhD work deals with the design, the fabrication and the study of high-coherence semiconductor laser sources emitting at 894 nm, for application to compact, optically-pumped cesium atomic clocks in an industrial context. We are particularly interested in the electrically pumped "Distributed-Feedback" in-plane laser diodes (DFB). The aim is to obtain a low-threshold, single-mode laser with high optical efficiency and a linewidth of less than 1 MHz. We first deal with the design and first-order characterization of the DFB diodes until they are put into modules for the clock. We then carry out an in-depth study of the physical properties of the laser emission in terms of coherence time. For that purpose, a new universal method for characterizing the optical frequency noise is introduced. Finally, we look further into the spectral properties of the emission in a servo configuration on a fluorescence line of the cesium ("Dither-Locking"). We show that the intrinsic properties of the component satisfy the requirements of the industrial system as defined in the study.
223

Caractérisation spatio-temporelle d’impulsions laser de haute puissance / Spatiotemporal characterization of ultra-intense laser pulses

Pariente, Gustave 05 January 2017 (has links)
Les lasers de haute puissance permettent d'atteindre des intensités très importantes (jusqu'à 10²²W.cm⁻²). Parvenir à ce niveau d'intensité nécessite de concentrer une quantité modérée d'énergie (de l'ordre du joule) dans un temps très court (de l'ordre de la dizaine de femtosecondes) sur une surface réduite (de l'ordre du μm²). Ces faisceaux sont donc ultra-courts et focalisés à l'aide d'une optique à grande ouverture. Ces caractéristiques signifient que leur diamètre avant focalisation est grand et leur largeur spectrale est importante. Pour cette raison, ces faisceaux sont à même de présenter des distorsions spatio-spectrales (ou couplages spatio-temporels). Après focalisation, ces distorsions ont pour effet une diminution drastique de l'intensité pic. Ceci est d'autant plus vrai que le système laser est puissant et donc que son diamètre et sa largeur spectrale sont grands. En dépit de cet effet néfaste, les couplages spatio-temporels présentent aussi un intérêt lorsqu'ils sont maitrisés. On peut en effet introduire des couplages spatio-temporels de faible amplitude à des fins expérimentales. Dans les années 1990 et 2000, un effort important a été fourni pour permettre la caractérisation et l'optimisation du profil temporel des lasers femtoseconde. Dans le même temps, des solutions d'optique adaptative ont été développées pour contrôler le profil spatial des faisceaux ultra-intenses et obtenir la meilleure tache focale possible. Les systèmes laser de haute-puissance actuels sont maintenant caractérisés et optimisés indépendamment par ces deux types de diagnostics. Par essence, cette approche est aveugle aux couplages spatio-temporels. Seule une caractérisation spatio-temporelle permettrait de mesurer ces distorsions. Il existait déjà des méthodes de caractérisation spatio-temporelle avant le début de cette thèse. Aucun de ces dispositifs n'avait cependant été adapté à la mesure de faisceaux ultra-intenses. Lors de cette thèse, nous avons développé une nouvelle technique de caractérisation spatio-temporelle appelée TERMITES. Cette technique est basée sur un schéma de spectroscopie par transformée de Fourier auto-référencée. TERMITES nous a permis d'effectuer la première caractérisation spatio-temporelle totale d'un laser 100 TW (le laser UHI-100 du CEA Saclay). Les distorsions spatio-temporelles détectées à l'aide de ces mesures ont confirmé la nécessité d'une généralisation de la métrologie spatio-temporelle des lasers de haute puissance. / High power laser make it possible to reach very high intensities (up to 10²²W.cm⁻²). In order to get to this level of intensity, a moderate quantity of energy (on the order of the Joule) is concentrated in a very short time (on the order of tens of femtoseconds) onto a small surface (on the order of 1 μm²). These beams are therefore ultra-short and focused with a high aperture optic. These features mean that their diameter prior to focus is large and their spectral width is big. As a result, these beams are subject to spatio-spectral distorsions (of spatio-temporal couplings). After focus, these distorsions induce a dramatic reduction of the peak intensity. This situation is all the more true when the laser is more intense and its diameter and spectral width are therefore bigger. Despite their detrimental effects, spatio-temporal couplings can be of great interest when controlled. One can indeed introduce weak spatio-temporal couplings for experimental purposes. In the 1990s and 2000s, a big effort was put in order to characterize dans optimize the temporal profile of femtosecond lasers. Meanwhile, adaptative optics solutions were developed to control the spatial profil of ultra intense laser beams and provide the best focal spot achievable. By nature, this approach is blind to spatio-temporal couplings. Measuring these distorsions requires a spatio-temporal characterization. Before the start of this Phd thesis, spatio-temporal characterization methods already existed. Although none of these devices were ever adapted to the measurement of ultra-intense laser beams. During this Phd Thesis, we developped a new spatio-temporal characterization technique which we called TERMITES. This technique is based on a self-referenced Fourier transform spectroscopy scheme. TERMITES made it possible for us to perform the first total spatio-temporal characterization of a 100 TW laser (UHI-100 at CEA Saclay, France). The detection of spatio-temporal distorsions with the help of these measurements confirmed the need for a generalization of spatio-temporal characterization of ultra-high power lasers.
224

Application of a Multimodal Polarimetric Imager to Study the Polarimetric Response of Scattering Media and Microstructures / Application d'un imageur polarimétrique multimodal pour l'étude de la réponse optique de milieux et de microstructures diffusantes

Yoo, Thomas 10 December 2018 (has links)
Les travaux réalisés au cours cette thèse ont eu comme objectif l’étude de l’interaction de la lumière polarisée avec des milieux et des particules diffusants. Ces travaux s’inscrivent dans un contexte collaboratif fort entre le LPICM et différents laboratoires privés et publics. Des aspects très variées ont été traités en profondeur dont le développement instrumental, la simulation numérique avancée et la création de protocoles de mesure pour l’interprétation de donnés à caractère complexe.La partie instrumentale de la thèse a été consacrée au développement d’un instrument novateur, adapté à la prise d’images polarimétriques à différents échelles (du millimètre au micron) pouvant être rapidement reconfigurable pour offrir différents modes d’imagerie du même échantillon. Les deux aspects principaux qui caractérisent l’instrument sont i) la possibilité d’obtenir des images polarimétriques réelles de l’échantillon et des images de la distribution angulaire de lumière diffusé par une zone sur l’échantillon dont sa taille et position peuvent être sélectionnée par l’utilisateur à volonté, ii) le contrôle total de l’état de polarisation, de la taille et de la divergence des faisceaux utilisés pour l’éclairage de l’échantillon et pour la réalisation des images de celui-ci. Ces deux aspects ne se trouvent réunis sur aucun autre appareil commercial ou expérimental actuel.Le premier objet d’étude en utilisant le polarimètre imageur multimodal a été l’étude de l’effet de l’épaisseur d’un milieu diffusant sur sa réponse optique. En imagerie médicale il existe un large consensus sur les avantages de l’utilisation de différentes propriétés polarimétriques pour améliorer l’efficacité de techniques optiques de dépistage de différentes maladies. En dépit de ces avantages, l’interprétation des observables polarimétriques en termes de propriétés physiologiques des tissus se trouve souvent obscurcie par l’influence de l’épaisseur, souvent inconnue, de l’échantillon étudié.L’objectif des travaux a été donc, de mieux comprendre la dépendance des propriétés polarimétriques de différents matériaux diffusants avec l’épaisseur de ceux-ci. En conclusion, il a été possible de montrer que, de manière assez universelle, les propriétés polarimétriques des milieux diffusants varient proportionnellement au chemin optique que la lumière a parcouru à l’intérieur du milieu, tandis que le dégrée de polarisation dépend quadratiquement de ce chemin. Cette découverte a pu être ensuite utilisée pour élaborer une méthode d’analyse de données qui permet de s’affranchir de l’effet des variations d’épaisseur des tissus, rendant ainsi les mesures très robustes et liées uniquement aux propriétés intrinsèques des échantillons étudiés.Un deuxième objet d’étude a été la réponse polarimétrique de particules de taille micrométrique. La sélection des particules étudiées par analogie à la taille des cellules qui forment les tissus biologiques et qui sont responsables de la dispersion de la lumière. Grâce à des mesures polarimétriques, il a été découvert que lorsque les microparticules sont éclairées avec une incidence oblique par rapport à l’axe optique du microscope, celles-ci semblent se comporter comme si elles étaient optiquement actives. D’ailleurs, il a été trouvé que la valeur de cette activité optique apparente dépend de la forme des particules étudiées. L’explication de ce phénomène est basée sur l’apparition d’une phase topologique dans le faisceau de lumière. Cette phase topologique dépend du parcours de la lumière diffusée à l’intérieur du microscope. L’observation inédite de cette phase topologique a été possible grâce au fait que l’imageur polarimétrique multimodale permet un éclairage des échantillons à l’incidence oblique. Cette découverte peut améliorer significativement l’efficacité de méthodes optiques pour la détermination de la forme de micro-objets. / The work carried out during this thesis was aimed to study the interaction of polarized light from the scattering media and particles. This work is part of a strong collaborative context between the LPICM and various private and public laboratories. A wide variety of aspects have been treated deeply, including instrumental development, advanced numerical simulation and the creation of measurement protocols for the interpretation of complex data.The instrumental part of the thesis was devoted to the development of an innovative instrument, suitable for taking polarimetric images at different scales (from millimeters to microns) that can be quickly reconfigured to offer different imaging modes of the same sample. The two main aspects that characterize the instrument are i) the possibility of obtaining real polarimetric images of the sample and the angular distribution of light scattered by an illuminated zone whose size and position can be controlled, ii) the total control of the polarization state, size and divergence of the beams. These two aspects are not united on any other commercial or experimental apparatus today.The first object of the study using the multimodal imaging polarimeter was to study the effect of the thickness from a scattering medium on its optical response. In medical imaging, there is a broad consensus on the benefits of using different polarimetric properties to improve the effectiveness of optical screening techniques for different diseases. Despite these advantages, the interpretation of the polarimetric responses in terms of the physiological properties of tissues has been obscured by the influence of the unknown thickness of the sample.The objective of the work was, therefore, to better understand the dependence of the polarimetric properties of different scattering materials with the known thickness. In conclusion, it is possible to show that the polarimetric properties of the scattering media vary proportionally with the optical path that the light has traveled inside the medium, whereas the degree of polarization depends quadratically on the optical path. This discovery could be used to develop a method of data analysis that overcomes the effect of thickness variations, thus making the measurements very robust and related only to the intrinsic properties of the samples studied.The second object of study was to study the polarimetric responses from particles of micrometric size. The selection of the particles studied by analogy to the size of the cells that form the biological tissues, and which are responsible for the dispersion of light. By means of the polarimetric measurements, it has been discovered that when the microparticles are illuminated with an oblique incidence with respect to the optical axis of the microscope, they appear to behave as if they were optically active. Moreover, it has been found that the value of this apparent optical activity depends on the shape of the particles. The explanation of this phenomenon is based on the appearance of a topological phase of the beam. This topological phase depends on the path of the light scattered inside the microscope. The unprecedented observation of this topological phase has been done by the fact that the multimodal polarimetric imager allows illumination of the samples at the oblique incidence. This discovery can significantly improve the efficiency of optical methods for determining the shape of micro-objects.
225

Imagerie interférométrique en défaut de mise au point pour des mesures de particules discrètes en volume et la reconnaissance de forme de particules irrégulières / Interferometric particle imaging for particle characterization in a volume and shape recognition of irregular particles

Ouldarbi, Lila 14 June 2017 (has links)
Les structures immergées telles que des hydroliennes génèrent des écoulements turbulents pouvant fortement perturber les fonds marins. La compréhension de l’impact de la présence de ces structures nécessite de comprendre la dynamique tridimensionnelle des tourbillons qu’elles génèrent. Les méthodes optiques, par leur aspect non intrusif, permettent d’analyser de telles dynamiques. L’imagerie interférométrique en défaut de mise au point est une technique développée à l’originepour la mesure de taille de particules sphériques transparentes telles que des gouttes ou des bulles. Nous proposons ici l’extension de cette technique à la mesure simultanée de particules irrégulières et sphériques. Un premier montage expérimental a permis de valider la méthode pour la mesure de taille et de position tridimensionnelle de grains de sable et de bulles d’air dans l’eau. Un second dispositif a été réalisé sur un canal à houle de plus grandes dimensions, permettant d’introduire les notions de suivi tridimensionnel de particules irrégulières et d’analyse de variation de leur orientation. Un troisième montage composé de deux dispositifs d’imagerie interférométrique selon deux angles d’observations est utilisé pour la reconnaissance de forme de différentes familles de particules irrégulières. Grâce à des comparaisons avec des simulations, les dimensions et l’orientation de ces particules sont déterminées. Ce type de montage devrait être adapté à la caractérisation de cristaux de glace dont divers types de formes sont connus. Ces travaux ouvrent des perspectives pour l’extension de la technique aux mesures de vitesses de particules dans des écoulements hostiles, combinées avec la reconnaissance de forme et la détermination de la rotation de particules. / Submerged structures such as tidal turbines generate turbulent flows that can strongly disrupt the seabed. Understanding the impact of the presence of these structures requires understanding the three-dimensional dynamics of the vortices they generate. Optical methods, by their non-intrusive aspect, make it possible to analyze these dynamics. Interferometric Particle Imaging is a technique originally developed for the measurement of transparent spherical particles such as droplets orbubbles. We offer here an extension of this technique for the simultaneous characterization of irregular and spherical particles in a flow. A first experimental set-up has confirmed the validity of the method for the size and three-dimensional position measurement of grains of sand and air bubbles in water. A second device was used on a wave flume of bigger dimensions, introducing the notions of three-dimensional tracking of irregular particles and the analysis of the variation of their orientation.A third device made of two Interferometric Particle Imaging set-ups at two angles of observation is described for the shape recognition of different families of irregular particles. Through comparisons with simulations, dimensions and orientations of these particles are determined. This kind of device should be suitable for the characterization of ice crystals for which various shapes are known. The prospects that such results provide include the extension of the technique to the particle velocitymeasurement in hostile conditions, combined with the shape recognition and the determination of rotation of particles.
226

Caractérisation 3D d’un nuage de particules par imagerie interférométrique de Fourier : positions relatives 3D, tailles et indices de réfraction / 3D characterization of a cloud of particles by Fourier interferometric imaging : 3D relative positions, sizes and refractive indices

Briard, Paul 05 December 2012 (has links)
Dans ce mémoire, je propose une nouvelle technique optique de mesure de positions relatives 3D, tailles et indices de réfraction d’un ensemble de particules, éclairées par un faisceau laser plan pulsé : l’imagerie interférométrique de Fourier (FII). Dans le cadre de ce travail, les particules sont sphériques, homogènes transparentes et isotropes. Lorsque ces particules sont éclairées, elles se comportent comme des sources d’ondes lumineuses sphériques qui interférent entre elles. L’enregistrement des franges d’interférences et leur analyse par transformation de Fourier peut permettre d’accéder aux caractéristiques des particules. Dans ce mémoire, je décris l’influence des caractéristiques de particules sur les représentations spectrales des franges d’interférences crées par les couples de particules éclairées dans l’espace de Fourier 2D. Les franges d’interférences sont simulées numériquement en utilisant la théorie de Lorenz-Mie. Puis j’aborde le problème inverse en montrant comment il est possible de retrouver les caractéristiques des particules, en me servant de l’optique géométrique et du filtrage spatial par transformation de Fourier. / In this thesis, I propose a new optical technique for measuring 3D relative positions, sizes and refractive indices of a set of particles, which are illuminated by a plane and pulsed laser beam. In this work, the particles are spherical, transparent, homogeneous and isotropic. When these particles are illuminated, they have the behavior of sources of spherical light waves which interfere. The recording of interference fringes and analysisby Fourier transform can measure the characteristics of the particles. I describe the influence of particle characteristics on spectral representations of the interference fringes created by the pairs of particles illuminated in 2D Fourier space. The interference fringes are simulated numerically using the Lorenz-Mietheory. The inverse problem is approached by showing how it is possible to measure the characteristics of particles with geometrical optics and spatial filtering by Fourier transformation.
227

Détection non destructive en cavité pour des horloges à réseau optique au strontium / Cavity non destructive detection on an optical lattice clock

Vallet, Grégoire 13 December 2018 (has links)
Les travaux réalisés dans le cadre de cette thèse ont consisté en la réalisation d'un système de détection non destructif assisté par cavité d'atomes piégés sur réseau optique pour l'amélioration de la stabilité d'une horloge optique au strontium. La caractérisation de ce système dans son fonctionnement en régime classique, dans lequel les atomes piégés diffusent suffisamment peu de photons pour ne pas être expulsés du piège durant la détection, a mis en évidence des améliorations significatives en termes de rapport signal à bruit avec un gain d'un facteur cent en comparaison avec le système précédent de détection par fluorescence. Les gains en termes de stabilité par réduction de l'effet Dick restent cependant à concrétiser.Pour la réalisation du régime quantique, dans lequel moins d'un photon est diffusé par atome durant la détection, des idées nouvelles et des changements significatifs ont du être opérés sur le système et un travail théorique conséquent a été entrepris afin de déterminer la stratégie permettant une amélioration de la stabilité par réduction du bruit de projection quantique par mesure sans démolition de la cohérence de l'état interne atomique.J'y ai également aborder l'étude des effets des collisions chaudes des atomes de strontium piégés avec les particules du fond de vide résiduel, permettant une amélioration de l'exactitude de l'horloge. Cette thèse rapporte en particulier la première mesure expérimentale du déplacement de la fréquence de transition d'horloge due à ces collisions ainsi que son étude théorique. / The work achieved in the frame of this PhD training consisted in the implementation of a cavity enhanced non destructive detection system of atoms trapped in an optical lattice aiming at improving the stability of an optical strontium clock.The characterization of the system in its classical regime, for which a sufficiently low number of photons are scattered per atom to avoid expelling them off the trap, highlighted significant improvements in term of signal to noise ratio, with gain factor around 100 compared with the previously used fluorescence scheme. Yet, gains in terms of stability via Dick effect reduction still have to be demonstrated.Regarding the quantum regime, for which less than one photon is scattered per atom over the detection, new ideas and significant changes have been carried out on the system and a theoretical study was has been undertaken to determine the strategy for the improvement of the clock stability by quantum projection noise reduction via quantum non demolition measurement.It was as well the opportunity to study the effect of the hot collisions between the trapped strontium atoms and the residual vacuum background gas particles, allowing for the improvement of the clock uncertainty. This work reports in particular on the first measurement of strontium clock hot collisions shifts as well as its theoretical study.
228

Réalisation et caractérisation de dispositifs de mesure associés à la détermination de la constante de von Klitzing à partir d’un condensateur calculable étalon dit de Thompson-Lampard / Realization and characterization of the measurement devices associated to the determination of the von Klitzing constant from a standard calculable capacitor said Thompson-Lampard

Sindjui, Ralph 01 July 2016 (has links)
Le sujet de thèse s'inscrit dans le cadre d'un nouveau projet de détermination de la constante de von Klitzing débuté depuis quelques années au LNE et dont l'aboutissement est prévu pour 2018. A ce jour, la mesure la plus exacte de cette constante traçable au Système International d’unités (SI) est obtenue via le raccordement de l'ohm produit par l'effet Hall quantique au farad, matérialisé à l'aide d'un condensateur calculable dit de Thompson-Lampard. Afin d'améliorer sa précédente détermination délivrée en 2000 avec une incertitude relative de 5.10-8,le LNE a décidé de construire un nouvel étalon calculable de Thompson-Lampard (déjà en cours de développement) et d'améliorer l'exactitude de l'ensemble des dispositifs de mesure associés avec pour objectif de réduire l’incertitude globale sur cette détermination à une valeur proche de 10-8. Le travail de thèse porte sur la réalisation, la caractérisation et/ou l’automatisation de la chaîne de mesure associée à cette détermination. / The comparison of electrical quantities expressed in units of the International System of Units (SI) and the same quantities generated from quantum effects is a direct way of determining physical constants. The determination of the von Klitzing constant (quantum of resistance) from a calculable capacitor is a part of this process. The last determination of this constant was conducted at LNE in 2000 with an uncertainty of 5.10-8. To achieve a target uncertainty of 1.10-8, the LNE decided to build a new standard capacitor and improve the associated measurement chain. The work presented here is implemented in the framework of the design/amelioration and the characterization of the measurement chain leading to the relative uncertainty of 1.10-8. Exploratory studies were also conducted about the possible partial or full automation of elements of the measurement chain.
229

L'apport des nouvelles technologies de mesure pour la caractérisation des sources et puits de gaz à effet de serre / The benefits of new innovative technologies for balancing the greenhouse gas emissions using atmospheric measurements

Lebegue, Benjamin 17 May 2016 (has links)
Au cours des trois dernières décennies, les programmes d'observation des GES se sont orientés vers des échelles de plus en plus fines. Il est devenu indispensable de développer les réseaux d'observation pour s'adapter aux échelles visées. On s'oriente également vers une augmentation des espèces observables afin de disposer d'une palette de traceurs atmosphériques. Dans le cadre de l'infrastructure de recherche européenne ICOS, le Laboratoire des Sciences du Climat et de l’Environnement (LSCE) est en charge de la veille technologique en matière d’instruments de mesure des GES. Dans le cadre de ma thèse, j’ai évalué en premier lieu les performances d’un spectromètre infrarouge à transformée de Fourier (FTIR) ciblant cinq composés: N2O, CH4, CO, CO2 et son isotope 13CO2.Hormis le FTIR, d’autres nouvelles techniques sont apparues sur le marché, en particulier concernant la mesure du N2O. Contrairement au CO2 et CH4 les stations ICOS n'ont pas encore l'obligation de mesurer le N2O car aucun instrument n'a été reconnu comme suffisamment performant. Dans le cadre de ma thèse j'ai eu la responsabilité de faire l'évaluation de sept analyseurs de N2O provenant de cinq constructeurs différents. Grâce à cette étude, j’ai pu regrouper les analyseurs en deux catégories : les instruments performants pour de hautes fréquences de mesures (<1 min) et les instruments stables sur le long terme. La première catégorie est plus adaptée aux mesures des échanges avec les écosystèmes par la méthode des flux turbulents, alors que la deuxième permet le suivi à haute précision dans l'atmosphère. La plupart des instruments présentent une sensibilité aux variations de température ambiante ainsi qu’une correction de la vapeur d’eau insuffisante (Lebegue et al., 2016).Par la suite, j’ai utilisé les données de N2O obtenues avec le FTIR afin de déterminer les émissions de ce gaz à l’aide de la méthode Radon qui repose sur la corrélation entre l’accumulation nocturne du 222Rn et celle de N2O. L’instrument FTIR proposant une meilleure justesse de mesure que le GC utilisé par le passé, j’ai pu obtenir un plus grand nombre d’évènements exploitables (+45%). Par la suite, j'ai installé le FTIR sur le site de Trainou, une tour radio près d'Orléans, début 2014 afin de caractériser les gradients verticaux de N2O et 13CO2.Le LSCE a acquis en mars 2015 un spectromètre laser de marque Aerodyne Research dédié à l’étude des échanges atmosphère-biosphère du carbone. Les trois composés cibles sont CO2, H2O et l’oxysulfure de carbone (COS). Dans la mesure où les plantes assimilent COS et CO2 et qu’il n’existe pas de mécanisme équivalent à la respiration du CO2 pour le COS, l’absorption du COS par les plantes serait directement proportionnelle à leur activité photosynthétique. Dans ce contexte, j’ai évalué les performances de l’instrument Aerodyne puis comparé ces dernières à celles du GC qui évalue depuis août 2014 les variations diurne et saisonnière du rapport de mélange à l’Orme des Merisiers. Enfin, j’ai installé l’instrument Aerodyne à la tour ICOS de Saclay afin d’y documenter les variations diurnes du gradient vertical de COS.Mes études montrent (1) que l'Aerodyne et le GC présentent des performances similaires mais que l'Aerodyne a l’avantage de nécessiter une maintenance nettement moins importante, et (2) que l’instrument Aerodyne est capable de détecter un gradient vertical de quelques ppt en période de stratification nocturne. Dans cette partie de mon travail de thèse, j’évalue aussi les variations saisonnières du COS dans la basse troposphère, déterminées à partir des données GC, que je compare à d’autres sites à travers le monde. J’ai également pu estimer sur cette période, par la méthode Radon, les vitesses de dépôt de COS sur le Plateau de Saclay. Cette méthode m’a permis de mettre en évidence l’existence d’un puits nocturne de COS dans la région du plateau de Saclay qui demeure actif quasiment tout au long de l’année. / During the last three decades, GHG observations programs went towards ever smaller scales, and it is becoming necessary to develop observation networks and adapt them to the different scales studied. Besides denser networks, we are going toward an increase of the species monitored in order to have a wide range of atmospheric tracers available to identify processes. As a member of the European research program ICOS (Integrated Carbon Observing System), the LSCE (Laboratoire des Sciences du Climat et de l’Environnement) is in charge of technological watch for GHG measuring analyzers. In the scope of my thesis, I first tested a Fourier Transform Infra-Red Spectrometer (FTIR) commercialized by Ecotech which can analyze five species: N2O, CH4, CO, CO2 and its isotope 13CO2.Apart of the FTIR, other new technologies appeared on the market, particularly relating to N2O measurements. Unlike CO2 and CH4, ICOS stations don’t require measuring N2O, as no instrument has been found to be performant enough concerning measurement precision and reliability for the ICOS network. During my thesis, I had the responsibility to make an exhaustive evaluation of seven analyzers of N2O from five different manufacturers. I’ve been able to gather the analyzers in two categories: those with good high frequency measurements (< 1 min) and those which are stable over long periods. The first category is particularly adapted to measurement of exchange rates between different ecosystems, whereas the second allows for high precision monitoring of the atmosphere. Most instruments show dependence to ambient temperature variations as well as a water vapor correction either useless or lacking (Lebegue et al., AMT, 2016).Then, I used N2O measurements from the FTIR in order to determine night emissions of this gas by using the Radon method which calculates the correlation between the nocturnal accumulation of 222Rn and N2O. Thanks to the better repeatability of the FTIR over the gas chromatograph one, I have been able to obtain more workable events than with the GC (+45%). Start of 2014, I installed the FTIR at the Trainou station, a radio tower near Orléans, in order to document the vertical gradients of N2O and 13CO2.The LSCE received in March 2015 a laser spectrometer from Aerodyne Research dedicated to the study of atmosphere/biosphere carbon fluxes. Three species are analyzed, CO2, H2O and carbonyl sulfide (COS) for which the mixing ratio in the troposphere is a million times smaller than CO2’s. Considering that vegetation assimilate COS and CO2 in similar proportions and that there is no mechanism similar to respiration for COS, the absorption of COS by the vegetation should be directly proportional to the photosynthetic activity. In this respect, I have characterized the performances of the new instrument Aerodyne. I then compared measurements of COS from this instrument to those obtained with a GC which document, since August 2014, the diurnal and seasonal variations of COS mixing ratios and fluxes at the LSCE. Finally, I installed the Aerodyne analyzer at the ICOS tower of Saclay in order to document the diurnal variations of the vertical gradient of COS during the winter period.My studies showed (1) that the Aerodyne and the GC show similar performances although the Aerodyne analyzer has the advantage of needing less maintenance, and (2) that the Aerodyne analyzer is able to detect a vertical gradient of a few ppt during a nocturnal stratification. Here, I also study the seasonal variations of COS in the low troposphere, from GC data, which I compare to other stations across the world. I’ve also been able to estimate over this period, with the Radon method, the deposition velocity of COS over the Saclay plateau. Thanks to this method, I was able to document a nocturnal sink active for almost the full year over the Saclay Plateau.
230

Inspection dimensionnelle - Une approche multi-capteurs pour la vérification des spécifications géométriques / Dimensional inspection - Multi-sensor approach for geometrical specification verification

Sadaoui, Sif Eddine 09 July 2019 (has links)
L'inspection dimensionnelle, qui consiste à vérifier la conformité géométrique des pièces vis-à-vis des spécifications, est une étape essentielle dans le cycle de vie des produits. Elle s’appuie de plus en plus sur la mesure multi-capteurs qui permet un gain de temps certain. Néanmoins, le gain de temps n'a de sens que si la qualité des résultats respecte le besoin métrologique. En effet, la mise en œuvre combinée de capteurs de technologie et de caractéristiques différentes engendre un certain nombre de problèmes qui affectent directement la qualité de la mesure. Dans ce travail, une approche d'inspection automatique utilisant un scanner combinant un capteur à contact avec un capteur laser-plan monté sur une MMT est proposée. Cette approche cherche à utiliser au mieux les capacités de chacun des capteurs, en privilégiant la mesure avec le capteur laser-plan dès lors que la qualité requise est obtenue pour un gain de temps. L’approche consiste à définir une séquence d’opérations de mesure de surfaces qui portent des spécifications, appelées entités d’inspection.Partant d'un ensemble d'orientations du scanner, la séquence d'opérations est établie pour chaque orientation par évaluation de l'aptitude du capteur laser puis celle du palpeur à mesurer les surfaces avec la qualité nécessaire. La gamme d'inspection est complétée par la définition optimale de la trajectoire du capteur laser-plan et celle du palpeur pour chaque orientation. La trajectoire finale exécutée sur machine MMT est obtenue par transformation et assemblage des deux trajectoires. À l'issue de l'exécution, la mesure avec les deux capteurs conduit à deux nuages de points hétérogènes qu’il convient de traiter avant l’évaluation finale des spécifications. / Dimensional inspection, which consists in verifying the geometric conformity of parts in terms of specifications, is an essential step in the product life cycle. Recently, dimensional inspection has been increasingly based on multi-sensor measurement that allows a significant time saving. However, time saving is only meaningful if the quality of the results respects the metrological requirements. Indeed, the combined use of sensors of different technologies and characteristics generates issues that affect the measurement quality. In this work, an automatic inspection approach using a scanner combining a contact sensor with a laser-plane sensor mounted on a CMM is proposed. This approach aims to best use the abilities of each of the sensors, giving priority to measurement with the laser-plan sensor as soon as the required quality is obtained for time saving. The approach consists in defining a sequence of surface measurement operations that have specifications, called inspection features.Starting from a set of scanner orientations, the sequence of operations is established for each orientation by evaluating the ability of the laser sensor and then that of the probe to measure surfaces with the required quality. The inspection plan is completed by the optimal definition of the laser-plane sensor path and the probe path for each orientation. The final path executed on the CMM machine is obtained by transforming and assembling the two paths. At the end of the execution, the measurement with the two sensors leads to two heterogeneous point clouds that must be processed before the final evaluation of the specifications.

Page generated in 0.394 seconds