• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 70
  • 2
  • 1
  • 1
  • Tagged with
  • 74
  • 60
  • 31
  • 30
  • 17
  • 13
  • 13
  • 13
  • 12
  • 11
  • 11
  • 10
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação biomecânica e fotoelástica da fixação das fraturas de sínfise mandibular usando parafusos canulados cônicos / Biomechanical and photoelastic evaluation of mandibular symphysis fracture fixation with cannulated conical screws

Falci, Saulo Gabriel Moreira, 1983- 02 November 2014 (has links)
Orientador: Roger William Fernandes Moreira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T16:02:50Z (GMT). No. of bitstreams: 1 Falci_SauloGabrielMoreira_D.pdf: 1799316 bytes, checksum: 1de035c12bc218e5f3759c843bc2025d (MD5) Previous issue date: 2014 / Resumo: O objetivo desse estudo foi comparar por meio de testes mecânicos e fotoelásticos o desempenho dos parafusos canulados cônicos utilizados na fixação de fraturas de sínfise mandibular com outros métodos de fixação. Dez mandíbulas de poliuretano foram utilizadas em cada grupo e fixadas da seguinte maneira: Grupo (PRP), duas miniplacas do sistema 2,0 mm, perpendiculares; Grupo (PLL), uma placa do sistema 2,4 mm e uma miniplaca do sistema 2,0 mm, paralelas; Grupo (PC), dois parafusos canulados cônicos do sistema 2,8 mm. Foram realizados testes de carregamento linear vertical em uma máquina de ensaio universal. O teste de ANOVA One-way e o teste de Tukey foram utilizados para verificar a diferença entre as médias. O teste fotoelástico foi realizado, com o auxílio de um polariscópio plano. Foi usada uma mandíbula de resina fotoelástica para cada grupo de fixação (PRP, PLL e PC). A avaliação dos dados do teste fotoelástico foi qualitativa e descritiva. Os resultados mostraram diferença entre os grupos (PC) e (PRP) nos deslocamentos de 1 mm (p=0,025), 3 mm (p=0,013), 5 mm (p=0,036) e 10 mm (p=0,022). No teste fotoelástico foi observada maior concentração de tensões na região próxima à base mandibular em todos os grupos. No grupo (PRP) e (PLL) foi observada maior concentração de tensões na região da placa mais próxima à base enquanto no grupo (PC) as franjas isocromáticas foram mais dispersas em toda região avaliada. De acordo com os resultados do estudo foi possível concluir que os parafusos canulados cônicos apresentaram um bom desempenho nos testes mecânicos e fotoelásticos, sendo uma opção viável para a fixação das fraturas de sínfise mandibular / Abstract: The aim of this study was to compare by mechanical and photoelastic tests, the performance of the cannulated screws in mandibular symphysis fractures and compare them with other fixations methods. Ten polyurethane mandibles were used in each group and fixed as follows: Group (PRP) 2 2.0-mm perpendicular miniplates; Group (PLL) 1 2.0-mm miniplate and 1 2.4-mm bone plate, parallels; Group (CS) 2 2.8-mm cannulated screws. Vertical linear loading tests were performed in a universal testing machine. Differences among means were analyzed by the One-Way ANOVA and Tukey test. The photoelastic test was carried out using a plane polariscope. One photoelastic mandible resin was used for each fixation group (PRP, PLL and CS). Data evaluation of the photoelastic test was qualitative and descriptive. The results showed differences between (CS) and (PRP) groups in 1 mm (p=0.025), 3 mm (p=0.013), 5 mm (p=0.036) and 10 mm (p=0.022), of displacement. The photoelastic test showed higher stress concentration, in all groups, close to mandibular base. In (PRP) and (PLL) groups, the stress concentration was observed closest to the plate fixed in mandibular basis, while the (CS) group showed more dispersed isochromatic fringes throughout the evaluated region. According to the results of this study, it was concluded that conical cannulated screws performed well in mechanical and photoelastic test, being a viable method for fixation of mandibular symphysis fractures / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
2

Atividade antiinflamatória, cicatrizante e antimicrobiana do extrato aquoso de aroeirado-Sertão a 20% (myracrodruon urundeuva fr. All.) Aplicado em fraturas expostas induzidas em mandíbula de coelho / Anti-inflammatory, healing and antimicrobial activities of the aqueous extract of the aroeira-do-sertão at 20% (myracrodruon urundeuva fr.all.) applied to induced exposed fractures in rabbit jaws

Mello, Manoel de Jesus Rodrigues de January 2007 (has links)
MELLO, Manoel de Jesus Rodrigues. Atividade antiinflamatória, cicatrizante e antimicrobiana do extrato aquoso de aroeira-do-sertão a 20% (Myracrodruon urundeuva fr. all.) aplicado em fraturas expostas induzidas em mandíbula de coelho. 2007. 78 f. Dissertação (Mestrado em Cirurgia) - Universidade Federal do Ceará. Faculdade de Medicina, Fortaleza, 2007. / Submitted by denise santos (denise.santos@ufc.br) on 2014-03-10T14:19:03Z No. of bitstreams: 1 2007_dis_mjrmello.pdf: 4634449 bytes, checksum: b728d53fb1d609995f6166b7c8508e41 (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2014-03-10T14:20:25Z (GMT) No. of bitstreams: 1 2007_dis_mjrmello.pdf: 4634449 bytes, checksum: b728d53fb1d609995f6166b7c8508e41 (MD5) / Made available in DSpace on 2014-03-10T14:20:25Z (GMT). No. of bitstreams: 1 2007_dis_mjrmello.pdf: 4634449 bytes, checksum: b728d53fb1d609995f6166b7c8508e41 (MD5) Previous issue date: 2007 / Controlling bone healing is of great importance to traumatology, since some of the guiding principles of this area are the cleaning of the wound, the early fixation of the fracture, to assure the viability of the bone supply, and prevent the infection, especially in exposed fractures. The Aroeira-do-Sertão (Myracrodruon urundeuva Fr.All), tree of Anacardiceae family, is known for its popular uses as anti-inflammatory due to its healing activities, being a good therapeutic alternative. To investigate these properties we analyzed an experimental model using induced exposed fractures in rabbit jaws. Thirty white New Zealand male rabbits weighing between 1700 and 2100g, divided in two groups of fifteen animals each were used. The rabbits underwent surgical procedure under general anesthesia to fracture their right mandibular body, which was exposed to oral cavity for 4 hours. Material from the fracture site was collected for microbiological analysis. The animals were randomly distributed according to the proposed treatment. In Group I, 300ml of aqueous extract of Myracrodruon urundeuva at 20% was used for the irrigation of the focus of the fracture for 5 minutes. In Group II, sterile saline solution 0.9% at the same volume was used at the same way as Group I. All animals underwent fracture reduction with internal rigid fixation using 1,5mm titanium mini-plates. Before euthanasia, postoperatory radiographs were done by subgroups at 7, 14, and 30 days for analysis of the consolidation of the fractures, after which the bone fragment of the operated region was removed for histological analysis using the Masson Tricromic method. The animals were analyzed from the clinical, radiological and histological perspectives. The clinical analysis consisted in the visual verification of the aspect of the surgical wound. Group I (Myracrodruon urundeuva) showed a little improvement in healing when compared to Group II. Radiographically Groups II did not presented significant effects in the consolidation of the bone. Histologically reduction of the bacterial concentration was showed in the fracture in the Group I. The conclusion was that a Myracrodruon urundeuva aqueous extract at 20% has no significant effect in the consolidation of induced exposed fractures of rabbit jaws, but shows benefits in the healing of wounds, reducing the colonies of bacteria in the fractures sites significantly. / O controle da cicatrização óssea tem grande importância na traumatologia, visto que os princípios que norteiam esta área são a limpeza da ferida, reduções precoces com fixação do foco da fratura, assegurando viabilidade circulatória local, prevenindo a infecção, principalmente nas fraturas expostas. A aroeira-do-sertão (Myracroduon urundeuva Fr. All), árvore da família Anacardiácea, é conhecida pelo seu uso popular com atividades antiinflamatórias e cicatrizantes, surgindo como alternativa terapêutica. Diante dessas qualidades, foram analisadas suas atividades, utilizando um modelo experimental em fraturas expostas induzidas em mandíbula de coelhos. Foram utilizados trinta coelhos, brancos, da raça Nova Zelândia, machos, com peso variando entre 1700 a 2100g, distribuídos em dois grupos de quinze animais. Os coelhos foram submetidos a tratamento cirúrgico, sob anestesia geral, para realização de fratura do corpo mandibular direito, ficando exposta para cavidade bucal por um período de quatro horas. Em todos os animais foi realizada a coleta do material do foco de fratura para análise microbiológica. Os animais foram distribuídos ao acaso, conforme o tratamento proposto: no grupo I, foram utilizados 300ml da solução de extrato aquoso de aroeira a 20% para irrigação do foco de fratura, durante 5 minutos. No grupo II, foi utilizado soro fisiológico a 0,9%, no mesmo volume e no mesmo tempo do grupo I, para irrigação do foco de fratura. Em todos os animais foi realizada a redução da fratura com fixação interna rígida, utilizando miniplacas de titânio do sistema 1,5mm. Foram realizados controles radiográficos do pós-operatório dos 7, 14 e 30 dias para análise da consolidação da fratura. Os grupos foram redistribuídos em subgrupos conforme o dia de eutanásia em SG7, SG14 e SG30 onde foi realizada a remoção do bloco ósseo da região operada para análise histológica pelo método de coloração do Tricrômico de Masson. Os animais foram analisados do ponto de vista clínico, radiológico e histológico. Na análise clínica, foi verificado o aspecto da ferida cirúrgica. O grupo I (aroeira) mostrou resultado pouco significante na cicatrização da ferida, quando comparado com o grupo II. No aspecto radiológico, o grupo tratado com aroeira não apresentou efeitos significativos quanto à consolidação. Do ponto de vista histológico, houve uma redução da concentração de bactérias no foco da fratura no grupo tratado com aroeira. O extrato aquoso de aroeira a 20% não tem efeito significativo na consolidação óssea de fraturas expostas induzidas em mandíbula de coelhos, no entanto, houve benefício na cicatrização da ferida e uma diminuição significativa das colônias bacterianas no foco das fraturas.
3

Distribuição das tensões em próteses protocolo mandibulares com diferentes extensões de cantilever e material de revestimento oclusal

Medeiros, Rodrigo Antonio de [UNESP] 17 February 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-17Bitstream added on 2015-03-03T12:06:36Z : No. of bitstreams: 1 000799687.pdf: 2318580 bytes, checksum: 6de6ec46da88b8b9d6b603ce2ab8f4be (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste estudo objetivamos a avaliação da distribuição de tensões na interface osso/implante, por meio do método da fotoelasticidade, em próteses mandibulares tipos protocolos de Branemark, com diferentes extensões de cantilever, materiais de recobrimento estético e uso de intermediários. Foi confeccionado um modelo fotoelástico de uma mandíbula edêntula, contendo cinco implantes 4.0x13 mm hexágono externo (HE) entre os forames mentonianos. Os grupos foram divididos da seguinte forma: Grupo 1 – UCLA e barra metálica; Grupo 2 – UCLA e revestimento oclusal em resina acrílica; Grupo 3 – UCLA e revestimento em cerâmica; Grupo 4 – Intermediário e barra metálica; Grupo 5 – Intermediário e revestimento em resina acrílica; Grupo 6 – Intermediário e revestimento em cerâmica. Com auxílio de uma máquina de ensaio EMIC inicialmente as forças de 70 N foram aplicadas em um ponto anterior, no implante mais posterior e em diferentes extensões de cantilever (até 37,5mm do último implante) na barra metálica e posteriormente nas próteses confeccionadas com barra metálica e revestimento em cerâmica e resina acrílica. Por meio de imagens fotográficas e auxílio do programa Adobe Photoshop CS6 nas imagens obtidas após o teste foi realizada a análise das tensões de acordo com o número de franjas de alta intensidade e de acordo com a concentração e área de distribuição dessas tensões nos grupos testados. Os resultados mostraram um maior número de franjas de alta tensão com o aumento do cantilever, e melhor distribuição das tensões foram para os grupos com as próteses confeccionadas em resina acrílica e para os grupos que continham componente intermediário. Concluímos que o uso de intermediários com próteses protocolo em resina acrílica e a ausência do cantilever tende a apresentar menores números de franjas de alta tensão ao redor dos implantes / The aim of this study was to assess the stress distribution, through photoelastic method, on mandibular implant-supported prostheses (Brånemark protocol), associated with different cantilever lengths, aesthetic coating materials and implant abutment. One photoelastic model of an edentulous mandible was made. The model contained five external hexagon implants (HE) with 4.0mm diameters and 13mm lengths placed between the mental foramen. The groups were divided as follows: Group 1 - UCLA and metal bar; Group 2 - UCLA and occlusal acrylic resin coating; Group 3 - UCLA and porcelain coating; Group 4 - Abutment and metal bar; Group 5 - Abutment and acrylic resin coating; Group 6 - Abutment and porcelain coating. A force was applied, using a universal testing machine (EMIC), in different regions - in the most anterior implant, in the most posterior implant and in different cantilever extensions (up to 37.5 mm from the last implant) - in the metal bar and later in the metal bar with porcelain and acrylic resin coated prostheses. The results were obtained through photograph images and the Adobe Photoshop CS6 software was used for qualitative analysis. The analysis was performed according to the number of fringes with high intensity and to the stress distribution area. The results showed a greater number of high stress fringes as the cantilever extension increases. Groups with acrylic resin coating and with abutments exhibited greater stress distribution. We concluded that the use of abutments in acrylic resin protocol prostheses and the absence of the cantilever tends to decrease stress around implants / FAPESP: 12/11336-7
4

Distribuição das tensões em próteses protocolo mandibulares com diferentes extensões de cantilever e material de revestimento oclusal /

Medeiros, Rodrigo Antonio de. January 2014 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Daniela Micheline dos Santos / Banca: Marcelo Ferraz Mesquita / Resumo: Neste estudo objetivamos a avaliação da distribuição de tensões na interface osso/implante, por meio do método da fotoelasticidade, em próteses mandibulares tipos protocolos de Branemark, com diferentes extensões de cantilever, materiais de recobrimento estético e uso de intermediários. Foi confeccionado um modelo fotoelástico de uma mandíbula edêntula, contendo cinco implantes 4.0x13 mm hexágono externo (HE) entre os forames mentonianos. Os grupos foram divididos da seguinte forma: Grupo 1 - UCLA e barra metálica; Grupo 2 - UCLA e revestimento oclusal em resina acrílica; Grupo 3 - UCLA e revestimento em cerâmica; Grupo 4 - Intermediário e barra metálica; Grupo 5 - Intermediário e revestimento em resina acrílica; Grupo 6 - Intermediário e revestimento em cerâmica. Com auxílio de uma máquina de ensaio EMIC inicialmente as forças de 70 N foram aplicadas em um ponto anterior, no implante mais posterior e em diferentes extensões de cantilever (até 37,5mm do último implante) na barra metálica e posteriormente nas próteses confeccionadas com barra metálica e revestimento em cerâmica e resina acrílica. Por meio de imagens fotográficas e auxílio do programa Adobe Photoshop CS6 nas imagens obtidas após o teste foi realizada a análise das tensões de acordo com o número de franjas de alta intensidade e de acordo com a concentração e área de distribuição dessas tensões nos grupos testados. Os resultados mostraram um maior número de franjas de alta tensão com o aumento do cantilever, e melhor distribuição das tensões foram para os grupos com as próteses confeccionadas em resina acrílica e para os grupos que continham componente intermediário. Concluímos que o uso de intermediários com próteses protocolo em resina acrílica e a ausência do cantilever tende a apresentar menores números de franjas de alta tensão ao redor dos implantes / Abstract: The aim of this study was to assess the stress distribution, through photoelastic method, on mandibular implant-supported prostheses (Brånemark protocol), associated with different cantilever lengths, aesthetic coating materials and implant abutment. One photoelastic model of an edentulous mandible was made. The model contained five external hexagon implants (HE) with 4.0mm diameters and 13mm lengths placed between the mental foramen. The groups were divided as follows: Group 1 - UCLA and metal bar; Group 2 - UCLA and occlusal acrylic resin coating; Group 3 - UCLA and porcelain coating; Group 4 - Abutment and metal bar; Group 5 - Abutment and acrylic resin coating; Group 6 - Abutment and porcelain coating. A force was applied, using a universal testing machine (EMIC), in different regions - in the most anterior implant, in the most posterior implant and in different cantilever extensions (up to 37.5 mm from the last implant) - in the metal bar and later in the metal bar with porcelain and acrylic resin coated prostheses. The results were obtained through photograph images and the Adobe Photoshop CS6 software was used for qualitative analysis. The analysis was performed according to the number of fringes with high intensity and to the stress distribution area. The results showed a greater number of high stress fringes as the cantilever extension increases. Groups with acrylic resin coating and with abutments exhibited greater stress distribution. We concluded that the use of abutments in acrylic resin protocol prostheses and the absence of the cantilever tends to decrease stress around implants / Mestre
5

Análise estrutural dos efeitos da desadaptação em componentes de próteses odontológicas utilizando o método dos elementos finitos com elemento de contato e pré-carga

Silveira, Elton Carlos [UNESP] 22 May 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-05-22Bitstream added on 2014-06-13T18:34:47Z : No. of bitstreams: 1 silveira_ec_me_bauru.pdf: 2546556 bytes, checksum: 59edc9cc8640727fa8558fa7e3c24476 (MD5) / Áreas da bioengenharia têm desempenhado um importante papel nos avanços dos estudos das próteses dentárias. Um desses estudos, o das próteses odontológicas sobre implante, utilizadas em diversos tipos de tratamento para reabilitação oral, está relacionado ao problema de contato mecânico. Por substituir elementos do organismo, a prótese constantemente é submetida a esforços produzidos pela carga mastigatória que afetam diretamente os componentes desta unidade e o contato entre eles. Em muitas ocasiões o contato pode gerar tensões elevadas nos componentes da próteses causando falhas, desgastes e fraturas, o que consequentemente favorece a proliferação de bactérias, prejudicando o sucesso do implante. O problemas de contato, por ser muito comum em vários sistemas mecânicos, vem sendo amplamente estudado. No caso da prótese dentária sobre implante, o problema surge na abertura entre coroa e implante, acarretado frequentemente por dois motivos: pela pré-carga inadequada (força de aperto) ou pelas imperfeições geométricas na base da coroa. Estas imperfeições ocorrem devido ao processo de fabricação, e estão representadas no trabalho como desadaptação angular unilateral (gap). Evitar falhas e fratura neste sistema é de extrema importância, pois podem prejudicar tanto o processo de osseointegração do implante, quanto a saúde e o bem-estar do paciente. A utilização do Método dos Elementos Finitos (MEF) tem se mostrado muito eficaz na simulação de problemas biomecânicos, geralmente envolvendo a não linearidade do contato e a pré-carga. As análises que evidenciam estes problemas têm sido amplamente utilizadas nos estudos de próteses no intuito de melhorá-las. O presente trabalho tem como objetivo desenvolver, com base no Método dos Elementos Finitos (MEF), simulações em três dimensões de uma prótese... / Areas of bioengineering have played an important role in the progress of the studies of dental prostheses. One of these studies, the prostheses on dental implants, used in various types of treatment for oral rehabilitation in related to the problem of mechanical contact. Due to replace elements of the body, the prosthesis is constantly subjected to stresses produced by the masticatory load directly affect the components of this unit and the contact between them. On many occasions, the contact can generate high stresses on the components of the prosthesis causing failurres, wear and fractures, and this can allow the growth of bacteria, impairing the success of the implant. Because the problem of contact is very common in various prothesis, the problem arises in the gap between the crown and the implant. This problem frequently occurs because of two reasons: for inadequate preload (tightening force) or by geometric imperfections in the base of the crown. These imperfections occur due to the manufacturing process, and they are represented at this study as a unilateral angular misfit (gap). The prevention of failures and fractures in this system is very important; because they can damage the process of osseointegration of the implant, and the health and well-being of the patient as well. Thus use of the Finite Element Analysis (FEA) has been show to be very effective in the simulation of biomechanical problems, often involving the non-linear contact problem and preload. The analysis involving these problems have been widely used in the study of dental prosthesis in order to improve it. The present study aims to develop, based on the Finite Element Analysis(FEA), three-dimensional simulations of a prosthesis, with fixation between implant and crown via screw, subject to static load. For this were developed models with nonlinear contact and with variation... (Complete abstract click electronic access below)
6

Análise estrutural dos efeitos da desadaptação em componentes de próteses odontológicas utilizando o método dos elementos finitos com elemento de contato e pré-carga /

Silveira, Elton Carlos. January 2013 (has links)
Orientador: Edson Antônio Capello Sousa / Banca: Rogério Akhide Ikegami / Banca: Osvaldo Luis Manzoli / Resumo: Áreas da bioengenharia têm desempenhado um importante papel nos avanços dos estudos das próteses dentárias. Um desses estudos, o das próteses odontológicas sobre implante, utilizadas em diversos tipos de tratamento para reabilitação oral, está relacionado ao problema de contato mecânico. Por substituir elementos do organismo, a prótese constantemente é submetida a esforços produzidos pela carga mastigatória que afetam diretamente os componentes desta unidade e o contato entre eles. Em muitas ocasiões o contato pode gerar tensões elevadas nos componentes da próteses causando falhas, desgastes e fraturas, o que consequentemente favorece a proliferação de bactérias, prejudicando o sucesso do implante. O problemas de contato, por ser muito comum em vários sistemas mecânicos, vem sendo amplamente estudado. No caso da prótese dentária sobre implante, o problema surge na abertura entre coroa e implante, acarretado frequentemente por dois motivos: pela pré-carga inadequada (força de aperto) ou pelas imperfeições geométricas na base da coroa. Estas imperfeições ocorrem devido ao processo de fabricação, e estão representadas no trabalho como desadaptação angular unilateral (gap). Evitar falhas e fratura neste sistema é de extrema importância, pois podem prejudicar tanto o processo de osseointegração do implante, quanto a saúde e o bem-estar do paciente. A utilização do Método dos Elementos Finitos (MEF) tem se mostrado muito eficaz na simulação de problemas biomecânicos, geralmente envolvendo a não linearidade do contato e a pré-carga. As análises que evidenciam estes problemas têm sido amplamente utilizadas nos estudos de próteses no intuito de melhorá-las. O presente trabalho tem como objetivo desenvolver, com base no Método dos Elementos Finitos (MEF), simulações em três dimensões de uma prótese... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Areas of bioengineering have played an important role in the progress of the studies of dental prostheses. One of these studies, the prostheses on dental implants, used in various types of treatment for oral rehabilitation in related to the problem of mechanical contact. Due to replace elements of the body, the prosthesis is constantly subjected to stresses produced by the masticatory load directly affect the components of this unit and the contact between them. On many occasions, the contact can generate high stresses on the components of the prosthesis causing failurres, wear and fractures, and this can allow the growth of bacteria, impairing the success of the implant. Because the problem of contact is very common in various prothesis, the problem arises in the gap between the crown and the implant. This problem frequently occurs because of two reasons: for inadequate preload (tightening force) or by geometric imperfections in the base of the crown. These imperfections occur due to the manufacturing process, and they are represented at this study as a unilateral angular misfit (gap). The prevention of failures and fractures in this system is very important; because they can damage the process of osseointegration of the implant, and the health and well-being of the patient as well. Thus use of the Finite Element Analysis (FEA) has been show to be very effective in the simulation of biomechanical problems, often involving the non-linear contact problem and preload. The analysis involving these problems have been widely used in the study of dental prosthesis in order to improve it. The present study aims to develop, based on the Finite Element Analysis(FEA), three-dimensional simulations of a prosthesis, with fixation between implant and crown via screw, subject to static load. For this were developed models with nonlinear contact and with variation... (Complete abstract click electronic access below) / Mestre
7

Estudo prospectivo da alteração de sensibilidade do nervo alveolar inferior e mentual após fratura de mandíbula e tratamento cirúrgico / Prospective study of sensorial changes of inferior alveolar and mental nerves after mandible fracture and surgical treatment

Gonçalves, Gabriela Mayrink 18 August 2018 (has links)
Orientador: Marcelo Marotta Araújo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T06:14:08Z (GMT). No. of bitstreams: 1 Goncalves_GabrielaMayrink_M.pdf: 937635 bytes, checksum: f125cb468cecb76eca6327e215da26d9 (MD5) Previous issue date: 2011 / Resumo: O tratamento das fraturas mandibulares pode ser conservador ou cirúrgico. Dentre as complicações advindas do trauma e do tratamento das fraturas, destacam-se: comprometimento de vias aéreas, sangramento, perda ou danos aos dentes e osso alveolar, não-união, má-união, infecção, desordens temporomandibulares (especialmente em fraturas de côndilo), má-oclusão e lesões aos nervos, em especial ao alveolar inferior e mentual. O objetivo deste trabalho foi avaliar o grau de perda de sensibilidade e de recuperação do nervo alveolar inferior e mentual em pacientes vítimas de fraturas mandibulares, que foram submetidos ao tratamento cirúrgico. Foram avaliados 19 pacientes e 27 hemimandíbulas em 6 diferentes tempos: pré-operatório (T1) , pós-operatório de 1 semana (T2), pós-operatório de 1 mês (T3), pós-operatório de 3 meses (T4), pós-operatório de 6 meses (T5) e pós-operatório de 1 ano (T6). Para esta avaliação, foram utilizados métodos subjetivos e objetivos. Os subjetivos consistiram de um questionário com perguntas objetivas avaliando a perda de sensibilidade ao paciente. Para os testes objetivos foram demarcados 9 pontos em cada hemimandíbula. Cada um desses pontos foi analisado utilizando os filamentos de Semmes-Weinstein (estesiômetro), uma agulha de calibre 0,7mm e spray refrigerante. Foram feitos testes de sensibilidade dolorosa, sensibilidade tátil, sensibilidade térmica e de tração unidirecional. Para avaliar os resultados, foram utilizados os testes qui-quadrado para a hipótese de ausência de associação entre os indicadores de sensibilidade e as respostas do questionário e o teste de Cochran-Mantel e Haenszel para hipótese de igualdade. Todos os testes objetivos mostraram uma queda na sensibilidade no T2 estatisticamente significante (p < 0,0001) e uma melhora significativa após T4 (?<0,05). Os testes subjetivos mostraram associação com os objetivos, e foi observado relato de melhora da sensibilidade após T4 (p < 0,0001). Assim, conclui-se que a primeira semana pós-operatória é o período em que há maiores alterações em relação a sensibilidade e que após 3 meses de pós-operatório, a recuperação chega ao seu ápice, sendo pouca diferença observada após este período / Abstract: Mandibular fractures occur with greater frequency due to its prominent position in the face. The treatment can be conservative (using only intermaxillary fixation) or surgical. Among the complications of the trauma and treatment of fractures include: airway compromise, bleeding, loss or damage to teeth and alveolar bone, non-union or bad-union, infection, temporomandibular disorders (especially in condylar fractures ) and nerve injuries, in particular the inferior alveolar nerve. The aim of this study was to evaluate the degree of paresthesia and recovery of inferior alveolar nerve in patients with mandibular fractures who underwent surgical treatment. We evaluated 19 patients (27 hemi mandibles) at six different times: preoperatively (T1), postoperative 1 week (T2), postoperative 1 month (T3), postoperative 3 months (T4), postoperative 6 months (T5) postoperatively and 1 year (T6). For this evaluation, we used subjective and objective methods. The subjective questionnaire consisted in questions about the loss of sensitivity to the patient, while the objective test assessed the degree of paresthesia in 9 points in each hemimandible (the region between the mental foramen). To achieve the objective tests were used Semmes-Weinstein monofilaments (esthesiometer), a 0.3 mm gauge needle and freeze spray. Objective tests were: pain sensitivity, tactile sensitivity, thermal sensitivity and unidirectional traction. To evaluate the results were analyzed using Likelihood Ratio Chi-square test for the hypothesis of no association between indicators of sensitivity and responses to the questionnaire and the Cochran-Mantel-Haenszel test and for equality hypothesis. All objective tests showed a worsening in sensitivity at T2 statistically significant (p <0.0001) and a significant improvement after T4 (? <0.05). The subjective tests showed an association with the objectives tests, and noted a report of improvement in sensitivity after T4 (p <0.0001). Thus, we conclude that the first postoperative week is the period in which there are major changes with respect to sensitivity and after 3 months postoperatively the recovery reaches its apex with little difference observed after this period / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
8

Estudo comparativo da resistencia mecanica a flexão de placas e parafusos reabsorviveis e metalicos utilizados em osteotomias de corpo em mandibulas de poliuretano / Comparative biomechanical evaluation of flexion resistance between absorbable and metalic plate and screws used in mandibular body poliuretane

Rodriguez Chessa, Jaime Giuseppe 12 August 2018 (has links)
Orientador: Renato Mazzonetto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T05:52:39Z (GMT). No. of bitstreams: 1 RodriguezChessa_JaimeGiuseppe_M.pdf: 1416977 bytes, checksum: 2b782ab4c409f0bfb1fc8e34d43c205b (MD5) Previous issue date: 2008 / Resumo: O propósito deste trabalho foi avaliar e comparar a resistência mecânica à flexão de placas e parafusos metálicos e reabsorvíveis para fixação interna rígida. Foram utilizadas hemimandíbulas sintéticas de poliuretano, nas quais se realizou uma osteotomia entre o segundo pré-molar e o primeiro molar inferior, simulando uma fratura de corpo mandibular. Foram estabelecidos dois grupos para placas e parafusos metálicos e dois grupos para reabsorvíveis de acordo com a seguinte disposição: duas placas metálicas mantidas com parafusos monocorticais de 6 mm na zona de tensão e outra com parafusos bicorticais de 12 mm de comprimento na zona de compressão. Após a fixação rígida, foi realizado o teste de resistência à flexão em máquina de ensaio universal (Instron®, modelo 4411) programada com velocidade de deslocamento linear de 1 mm/min e com célula de carga de 500N para obtenção do valor da resistência à flexão em quilograma-força com incidência de carga em região de incisivo e pré-molar em cada um dos grupos estudados. Os resultados demonstraram não existir diferença estatisticamente significante entre os sistemas de fixação interna rígida de titânio e reabsorvível, quando avaliadas as variáveis deslocamento (em mm) e a carga de pico (em kgf) para os 4 grupos amostrais. / Abstract: The meaning of this study was to evaluate and compare the resistance to flexion between metallic and absorbable plates and screws for rigid internal fixation. It was used synthetic hemimandible of polyurethane, in which one was performed a straight cut between second premolar and first molar, simulating a breaking of mandibular body. It was established two groups for metallic plates and screws and two groups for absorbable according to following disposal: two metallic plates kept with 6mm monocortical screws in the tension zone and another one with 12mm bicortical screws in the compression zone. After the rigid fixation, it was carried out the flexion resistance test thru a universal assay machine (Instron®, model 4411) performed with 1mm/minute linear displacement speeding with 500N of bearing cell for attainment the flexion resistance value in kilogram-force with the load incidence in the incisor and premolar regions on each group studied. The results had demonstrated to not exist statistical significant difference between the titanium and absorbable systems, when evaluated the variable displacement (in mm) and the peak load (in kgf) for the 4 groups tested. / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
9

Tratamento de fraturas de mandíbulas atróficas : estudo epidemiológico, mecânico e análises de elementos finitos / Atrophic mandible fractures traetment : epidemiological study, mechanical and finite element analysis

Freire, Simei André da Silva Rodrigues, 1981- 07 March 2012 (has links)
Orientador: Luciana Asprino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T21:58:02Z (GMT). No. of bitstreams: 1 Freire_SimeiAndredaSilvaRodrigues_D.pdf: 1346412 bytes, checksum: 35f4f1e8f5181ebc1bf60768170c3f2c (MD5) Previous issue date: 2012 / Resumo: O objetivo desse trabalho foi avaliar a epidemiologia e características do tratamento de fraturas de mandíbula atrófica; comparar a resistência mecânica e a distribuição de tensões de três técnicas de fixação interna aplicadas em fraturas de mandíbulas atróficas. CAPÍTULO I: Dados foram coletados de pacientes vítimas de fraturas em mandíbulas atróficas em um período de dez anos (1999-2009). Os dados analisados continham informações demográficas e socioeconômicas, etiologia dos traumas, diagnóstico, tipos de traumas, deslocamento das fraturas, o método de fixação utilizado, região das fraturas, traumas associados, tempo decorrido entre o trauma e tratamento. A principal causa das fraturas em mandíbulas atróficas foi a queda da própria altura, acometendo principalmente pacientes do gênero masculino desempregados. A faixa etária mais acometida foi a de trinta a sessenta anos ocorrendo predominantemente fraturas bilaterais na região de corpo mandibular. CAPÍTULO II: Avaliou-se a resistência, in vitro, por meio de testes de carregamento linear a fixação de fraturas de mandíbulas atróficas com defeito de continuidade por meio de três sistemas de fixação. Foram utilizadas réplicas de mandíbulas humanas atróficas de poliuretano submetidas a simulação de fratura com defeito de continuidade de 15mm em corpo direito, fixadas pelos seguintes sistemas: Grupo 1 - sistema 2,4mm conventional, Grupo 2 - sistema 2,4 mm com travamento e Grupo 3 - sistema 2,0mm com travamento. Pelos resultados obtidos o sistema com travamento aumentou a resistência da fixação pela melhor e mais favorável distribuição de cargas, os sistemas 2,4mm de fixação interna estável testados apresentaram adequada resistência mecânica para tratamento de fraturas de mandíbulas atróficas com defeito de continuidade. CAPÍTULO III: Avaliou-se, in sílico, pelo método de elementos finitos a fixação de fraturas de mandíbulas atróficas por meio de três sistemas de fixação submetidas a testes de carregamento linear. Os modelos criados em elementos finitos de fratura de mandíbula atrófica foram fixados pelos seguintes sistemas, sistema 2,4mm convencional, sistema 2,4mm com travamento e sistema 2,0mm com travamento. Pelos resultados obtidos o sistema 2,4mm convencional demonstrou suportar toda carga aplicada nesta simulação, os sistemas com travamento apresentaram dissipação das tensões para região anterior e posterior da mandíbula e no sistema de fixação convencional as tensões se localizaram na porção entre os furos do sistema de fixação assim como no sistema com travamento, porém este ainda apresentou dissipação para os parafusos, com concentração crescente para região apical dos parafusos próximos a simulação do traço de fratura / Abstract: The aim of this study was to evaluate the epidemiology and treatment characteristics of atrophic mandibular fractures; to compare the mechanical strength and stress distribution of three internal fixation techniques applied in atrophic mandibles fractures treatment. CHAPTER I: Data were collected from patients suffering from atrophic mandibles fractures in a period of ten years (1999-2009). The data analyzed contained demographic and socioeconomic characteristics, etiology of trauma, diagnosis, types of trauma, displacement of the fractures, the region of fracture, associated trauma, time elapsed between trauma and treatment. The main cause of fractures in atrophic mandibles was fall accidents, affecting mainly male unemployed patients. The age group most affected was between thirty to sixty years occurring bilateral fractures predominantly in the mandibular body region. CHAPTER II: Resistance was evaluated in vitro by linear loading test in the atrophic mandible fracture simulation with continuity defect by three stable internal fixation systems. It was used replicas of human atrophic polyurethane mandible subjected to simulated fracture defect continuity of 15mm in right body region, fixed by the following systems: Group 1 - 2.4mm conventional system, Group 2 - 2.4 mm locking system and Group 3 - 2.0mm locking system. The results obtained with the locking system increased the resistance setting for the better and more favorable load distribution, the 2.4mm stable internal fixation systems tested had adequate mechanical strength for the treatment of fractures of atrophic mandibles with continuity defects. CHAPTER III: It was evaluated ,in silico, by the method of finite elements with linear force three stable internal fixation systems for the treatment of atrophic mandible fractures. The finite element models created in the atrophic mandible fracture were fixed by the following systems, the conventional system 2.4mm, 2.4mm locking system and 2.0mm locking system. The results obtained demonstrated that the locking system increased the resistance by a favorable and better distribution of the stresses during the loading test when applied in atrophic mandible fractures with continuity defects. The three internal fixation systems tested in this study showed adequate mechanical efficiency to be applied in atrophic mandible fractures with continuity defects treatment / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
10

Estudo das extensões dos movimentos horizontais mandibulares nos desdentados totais

Passos, Luiz Egydio Teixeira Leite 19 December 1997 (has links)
Orientador: Krunislave Antonio Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T07:35:01Z (GMT). No. of bitstreams: 1 Passos_LuizEgydioTeixeiraLeite_M.pdf: 3747769 bytes, checksum: aef62d7ac14ff5b83794a468a2a3e16f (MD5) Previous issue date: 1997 / Resumo: Estudos têm demonstrado que a perda da DVO levam a diminuição dos movimentos mandibulares. Propusemos neste estudo analisar os movimentos mandibulares horizontais, ântero-posterior (A/P), lateral direita (L/D), lateral esquerda (L/E) através de registros intra-orais em dez pacientes sem perda da DVO (controle) e dez desdentados com perda da DVO entre 11 a 12 mm. Os modelos foram montados em articulador semi-ajustável e confeccionados os registros intra-orais, um para o grupo controle e dois registros (R 'IND. 1' e 'R IND. 2') para o grupo com DVO alterada sendo 'R IND. 1' com perda da DVO e 'R IND. 2' com a DVO recuperada. Os valores médios da extensão dos movimentos foram A/P = 12,591 mm, LD = 10,665 mm, LE = 10,562 mm. Para o grupo com perda da DVO foram: 'R IND. 1' - A/P = 08,107 mm LD = 06,100 mm, LE = 06,720 e 'R IND. 2' - A/P = - 10,167 mm, LD = 9,308 mm, LE = 9,285 mm. Aplicando-se o teste T pareado no segundo grupo, houve diferença significativa ao nível de 5% entre 'R IND. 1' e 'R IND. 2' e aplicando-se o teste T em 'R IND. 2' e o grupo controle não houve diferença ao nível de 5%. Desta forma podemos concluir que pacientes desdentados totais com perda da DVO, apresentam uma redução da amplitude dos movimentos mandibulares que podem ser resgatados pela recuperação da dimensão vertical da face / Abstract: Studies have demonstrated that the loss of the VDO, result in decreasing of mandibulars movement. We have proposed in to study to analyse the horizontal mandibulars movement, (P/R = protusivelretrusive, R = right, L = leA), using intra-oral devices in twenty edentulou pacients, with half of them presenting no loss of the VDO between 10 an 11 mm. The complete dentures was moulded and the measures were reproduced with the facial arco The cast were prepared on the semi adjustable articulador and the intra oral devices were manufactured, being one for the contros group and two ones ('R IND. 1' and 'R IND. 2') for group with the altered VDO, being 'R IND. 1' with VDO loss and 'R IND. 2' with recovered VDO. The medium values of the movements extensions presented by the control group were: P/R=12,591; R=10,665; L=10,562. For the group with VDO loss the values were: P/R=08,107; R=06,100; L=06,720 and P/R=10,167; R=09,308; L=09,285, for the 'R IND. 1' and 'R IND. 2' group respectively. Applyng the paired T test, there was a significa tive difference at leveI of 5% between 'R IND. 1' and 'R IND. 2' for the mandibular border moviments we should restore the physiological VDO, its decrease result in reduction of the horizontal. Was conclued that, for recuring the mandibulars moviments of the total edentulous pacients, second group and no significative difference at this level for the 'R IND. 2' and the control grou / Mestrado / Fisiologia e Biofisica do Sistema Estomatognatico / Mestre em Odontologia

Page generated in 0.0561 seconds