• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 263
  • 8
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 273
  • 168
  • 106
  • 66
  • 40
  • 33
  • 28
  • 25
  • 23
  • 22
  • 20
  • 20
  • 20
  • 20
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Análise crítica dos critérios de seleção de respiradores para particulados em ambientes de mineração. / Critical analyses of Brazilian particulate respirator selection logic for mining workers.

Glaucia Christine Cortelini Gabas 04 June 2008 (has links)
Várias etapas dos processos de mineração geram quantidades significativas de materiais particulados, também chamados de aerodispersóides que, dependendo de suas características químicas e físicas, são importantes causadores de doenças ocupacionais denominadas pneumoconioses. Para proteger os trabalhadores desses ambientes, algumas medidas de controle podem ser adotadas. Dentre elas, a medida mais comum é através da utilização de respiradores aprovados. Neste trabalho é apresentada uma análise crítica dos procedimentos de seleção de respiradores para particulados estabelecidos no documento intitulado Programa de Proteção Respiratória (PPR) e proposta a adoção de outros critérios técnicos importantes para trabalhadores de ambientes de mineração. Através do levantamento bibliográfico em acervos nacionais e internacionais, regulamentações vigentes, coleta de dados em minerações e experiência profissional da autora foi possível situar o ambiente de mineração em relação à presença de materiais particulados, analisar a lógica de seleção relacionada com os requisitos legais vigentes no Brasil e identificar os respiradores mais comumente empregados nos ambientes de mineração. Como resultado deste trabalho foi possível discutir sobre o nível de proteção respiratória a que os trabalhadores de minerações brasileiras estão sujeitos e sugerir o uso de tipos de respiradores para algumas situações de exposição. / Significant amounts of particulate matter, also called aerosols, are generated in many steps of mining and depending on its chemical and physical characteristics they are important agents that causes occupational diseases, named pneumoconioses. In order to protect the workers of this environment, some controls can be adopted. Among them, the most common control is the use of approved respirators. In this work is presented a critical analysis of particulate respirators selection procedures that are established at Respiratory Protection Program document and indicated the adoption of other important technical criteria for mining workers. Through the national and international bibliographic information, current regulations, data collection in mining industries and author professional expertise it was possible creating a mining workplace overview related to the presence of particulate matter, analyzing the respirator selection logic considering the Brazilian legal requirements and identifying the most common respirators applied at mining workplace. As a result of this work it was possible to discuss about the respiratory protection level that Brazilian mining workers are subjected and to suggest the use of respirators in some exposure situation.
82

Análise dos efeitos do ciclo térmico nos processos de arqueamento e alinhamento de chassis rodoviários

Milesi, Daniel Angelo Zattera January 2015 (has links)
Em determinadas rotas de manufatura de componentes automotivos, principalmente de produtos do segmento rodoviário pesado, são muito comuns processos de desempeno a quente, assim como outros procedimentos como arqueamento e alinhamento de longarinas. O presente trabalho tem por objetivo traçar os principais impactos destes processos sobre os materiais ASTM A570 GR36-C e o aço de alta resistência e baixa liga norma DIN EN 10149 S700MC em uma rota de fabricação de produtos automotivos com interferência de um procedimento a quente. Esses materiais, quando submetidos a determinados ciclos térmicos para alinhamento a quente, através do aquecimento de algumas regiões pontuais e do posterior resfriamento ao ar calmo têm suas propriedades mecânicas alteradas. Para investigar estas modificações, foram reproduzidas as condições do processo atual para mapeamento de dados de temperatura para os subsequentes ensaios de laboratório. Comparando as amostras submetidas ao ciclo térmico, com as produzidas com a mesma matéria prima sem aquecimento, pode-se verificar o impacto causado pelo processo de alinhamento a quente utilizado sobre as propriedades mecânicas do material. Os resultados mostram que o aço ASTM A570 GR36-C não tem suas propriedades alteradas a ponto de inviabilizar o uso do material. Para o aço DIN EN 10149 S700MC as alterações são expressivas em todos os ciclos térmicos realizados. Com isso, ocorrem modificações na microestrutura pelo tratamento térmico ocasionando a diminuição de algumas propriedades mecânicas importantes, como tensão de escoamento, microdureza e limite de resistência à fadiga. Essas últimas variáveis foram correlacionadas e mostraram o mesmo comportamento. / In certain manufacturing routes of automotive components, especially of heavy road segment products are very common straightening processes hot, as well as other procedures such as bending and alignment of rails. This paper aims to draw the main impacts of these processes on ASTM A570 GR36-C materials and high strength low alloy steel DIN EN 10149 S700MC on a route manufacturing of automotive products with interference from a hot procedure. These materials, when subjected to certain thermal cycles to hot alignment by heating of certain individual regions and the subsequent cooling the still air have changed their mechanical properties. In order to investigate this, they were reproduced the conditions of the current process for temperature mapping data for subsequent laboratory tests. Comparing the samples subjected to thermal cycling with produced with the same raw material unheated, one can ascertain the impact caused by hot alignment process used on the mechanical properties of the material. The results show that the steel ASTM A570 GR36-C does not have its properties changed as to make the use of the material. To DIN EN 10149 S700MC Steel changes are significant in all thermal cycles performed. Thus, changes occur in the microstructure by heat treatment causing a reduction of some important mechanical properties such as yield strength, hardness and fatigue strength limit. The latter variables were correlated and showed the same behavior.
83

Análise comparativa de ferramentas revestidas por PVD e CVD no torneamento do aço ABNT 8620 /

Costa, Anderson Figueiredo. January 2016 (has links)
Orientador: Marcos Valerio Ribeiro / Coorientador: João Paulo Barros Machado / Banca: Maneol Cleber de Sampaio Alves / Banca: João Roberto Ferreira / Resumo: Com o atual avanço de propriedades dos materiais, novas alternativas estão sendo buscadas para manufaturas desses materiais. Entre os processos, a usinagem se caracteriza por ser um processo que emprega milhões de pessoas. Entretanto para alcançar tais objetivos melhorias nas propriedades das ferramentas se faz necessária. Neste seguimento, os revestimentos vêm apresentando avanços significativos, como pode-se destacar o revestimento por CVD (deposição química a vapor) que permite que a ferramenta seja empregada nas temperaturas em torno de 1200ºC. Nesta mesma linha vale destacar o revestimento por PVD (deposição física a vapor) normalmente em uma única camada, o qual permite que a aresta de corte seja positiva, possa trabalhar com menor esforço de corte, e em temperatura aproximadamente em 700ºC. Este trabalho tem como objetivo analisar comparativamente o desempenho de ferramentas de metal duro revestidas pelo processo CVD e PVD no torneamento do aço ABNT 8620 sem uso de fluido de corte. Foram utilizadas duas pastilhas de metal duro revestidas pelo processo de PVD e CVD, com mesma geometria para efeito comparativo. A pastilha revestida por PVD tem espessura do revestimento de 3µm, enquanto que a pastilha revestida por CVD tem espessura do revestimento de 16µm. As pastilhas revestidas foram caracterizadas quanto a composição química dos elementos de revestimentos utilizando um microscópio eletrônico de varredura pela técnica de linescan e mapping. Posteriormente as ferramenta... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: With the current advancement of material properties, new alternatives are being sought for manufacturing these materials. Among the processes, machining is characterized as a process that employs millions of people. However to achieve such goals improvements in the tools properties is necessary. In this follow-up, the coatings have shown significant advances, as can highlight the coating by CVD (chemical vapor deposition) that allows the tool to be used at temperatures around 1200°C. In the same line it is worth highlighting the coating by PVD (physical vapor deposition) usually in a single layer, which allows the cutting edge is positive, can work with less shear stress, and temperature approximately 700°C. This study aims at comparing the performance of carbide tools coated by the CVD process and PVD in the steel turning ABNT 8620 without the use of cutting fluid. We used two carbide inserts coated by the PVD and CVD process, with the same geometry for comparison purposes. The tablet is coated by PVD coating thickness of 3μm, while the tablet is coated by CVD coating thickness of 16μm. The coated tablets were characterized as the chemical composition of coatings elements using a scanning electron microscope for linescan technique and mapping. Subsequently the tools were applied to turning the cutting speed (Vc) between 350 to 500 m/min, feed (f) 0.20 mm/rev and depth of cut (ap) of 1.00mm using a lathe ROMI mark, GL240M model. The characterizations were carried out using an optical microscope, scanning electron microscope and roughness. The results demonstrated that the tool coated by the CVD process has a better performance when compared to PVD this occurred because the tool coated by the CVD process has a multilayer coating having a higher heat input, supporting thus cutting temperatures ... (Complete abstract click electronic access below) / Mestre
84

Failure analysis of GRP pipes under compressive ring loads

Faria, Hugo Queirós de January 2005 (has links)
Tese de mestrado. Faculdade de Engenharia. Universidade do Porto. 1998
85

Desenvolvimento de sistemas de recolha de resíduos sólidos urbanos

Laranjeira, Luís Carlos de Sá January 2008 (has links)
Estágio realizado na TNL e orientado pelo Eng.º Nuno Silva / Tese de mestrado integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2008
86

Caracterização geométrica e mecânica experimental de paredes portantes de alvenaria de pedra

Gomes, Ana Luísa Zeferino January 2012 (has links)
Dissertação de mestrado integrado. Mestrado Integrado em Engenharia Civil - Especialização em Estruturas. Faculdade de Engenharia. Universidade do Porto. 2012
87

Avaliação experimental das principais propriedades mecânicas de peças estruturais em madeira antiga

Pereira, Samuel Soares Camarinha January 2009 (has links)
Tese de mestrado integrado. Engenharia Civil (Especialização em Construções Civis). Faculdade de Engenharia. Universidade do Porto. 2009
88

Comportamento mecânico de implantes modificados na região de ápice : análise pelo método de elementos finitos, fotoelasticidade, torque de inserção e frequência de ressonância /

Sciasci, Plínio. January 2017 (has links)
Orientador: Luís Geraldo Vaz / Resumo: A proposta deste estudo foi analisar o comportamento mecânico e a distribuição de forças de diferentes geometrias de ápice em implantes cilíndricos por meio de método de elementos finitos (MEF), fotoelasticidade, torque de inserção e frequência de ressonância. Foram usinados quatro tipos de implantes: sem corte apical (A), com corte apical bi-partido (B), corte apical tri-partido (C), corte apical quadri-partido (D) e um quinto (grupo controle) implante Titamax Ti Ex (Neodent, Curitiba, Paraná, Brasil) (E), todos com dimensões (4,1 X 11,0 mm) de plataforma hexagonal externa. Para o ensaio fotoelástico, blocos de acrílico (30X30X10mm) com um implante foram copiados com Borracha Silicone. Dentro de cada molde de silicone foi vertido resina fotoelástica semi-fexível. Para o ensaio fotoelástico duas situações foram simuladas: aplicação de carga axial de 1 kgf e em outro momento aplicação do torque de 10 N.cm. As fotografias realizadas no polariscópio circular foram transferidas para um computador para leitura dos parâmetros fotoelásticos no software powerpoint (Office 2010). Para o estudo de elementos finitos, o desenho dos implantes foram reproduzidos em CAD (computer Aided design) através do software Autodesk Inventor® (versão 2015, São Paulo, Brasil) e o bloco ósseo tipo IV de dimensões (2X2X2cm) foram posteriormente processados pelo software Rhinoceros v5.0 SR8 (McNeel North America, Seattle, WA, USA). As simulações foram executadas pelo software (Ansys Workbench 10.0, Swanso... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to analyze the mechanical behavior and force distribution of five different implant designs using finite element method (FEM), photoelasticity, insertion torque and resonance frequency of different geometric modifications proposed for the apex region Of cylindrical implants. Four types of implants were machined: without apical cut (A), with a two-part apical cut (B), apical tri-split cut (C), apical cut quadri-split (D) and fifth group was composed by Titamax Ti Ex Neodent all with dimensions (4.1 X 11.0 mm). For the photoelastic test, acrylic blocks (30X30X10mm) with implant installed were copied with Blue ASB-10 Silicone Rubber (Polipox). Inside each silicone mold was poured semi-flexible photoelastic resin (Polipox). A titanium UCLA prosthetic intermediate was screwed onto the implant and a dental crown on (Ni-Cr) was fixed on the set. For the photoelastic test two situations were simulated: application of axial load of 1 kgf and torque of 10 N.cm. The photograph and the reading of the photoelastic parameters were performed in a circular polariscope. For the finite element study, the computerAided design (CAD) implants and a Type IV human bone block of dimensions (2X2X2cm) were processed by the software Rhinoceros v5.0 SR8 (McNeel North America, Seattle, WA, USA) At the Renato Archer Information Technology Center (CTI, Campinas, São Paulo - Brazil). The mechanical properties of the implant (titanium grade II) and normal bone type IV were obtai... (Complete abstract click electronic access below) / Doutor
89

Influência da microfissuração causada nas primeiras idades na durabilidade de concretos ao longo do tempo (Self-Healing)

Venquiaruto, Simone Dornelles January 2017 (has links)
A racionalização e industrialização da construção promoveram profundas modificações no processo construtivo e nas técnicas gerenciais no Brasil. Muitas empresas construtoras, para garantir competitividade no mercado, buscaram soluções capazes de aumentar a velocidade de suas obras, tais como a redução do período de escoramento. A retirada antecipada do escoramento submete a estrutura a carregamento precoce, podendo desencadear a microfissuração do concreto. Como consequência, as deformações instantâneas e lentas tendem a aumentar e, consequentemente, manifestações patológicas podem ocorrer com maior intensidade. Objetivando simular o dano causado pela retirada antecipada do escoramento em idades iniciais, este trabalho investigou a influência do carregamento precoce por compressão axial na durabilidade de concretos distintos. O programa experimental foi executado em duas etapas. A primeira, investigou a influência da microfissuração causada por carregamento precoce na durabilidade de concretos produzidos com três tipos de cimento (CPV-ARI, CPIV RS e CPII Z) e três relações água/cimento (0,35, 0,50 e 0,70). Os carregamentos dos corpos de prova foram realizados em laboratório nas idades de 1, 3 e 7 dias. Para cada idade de carregamento foram rompidas, até o limite, duas amostras de referência e, a partir do valor médio de ruptura obtido, determinava-se os percentuais de carga (25%, 50% e 75%) que seriam aplicados nos concretos. Após o período de cura de 28 dias, as amostras foram ensaiadas à Penetração de Íons Cloreto e à Absorção Capilar de Água. A segunda etapa do programa experimental investigou a influência do prolongamento da cura na recuperação do dano causado pelo carregamento dos concretos nas primeiras idades. Foram produzidos concretos com dois tipos de cimento (CPV-ARI e CPIV) e uma relação água/cimento (0,50). Parte dos concretos receberam pré-carregamento de 75% da carga de ruptura na idade de 3 dias e parte permaneceu intacta, para servir como referência. Os ensaios mecânicos e de durabilidade (penetração de íons cloreto) foram executados ao longo do tempo (3, 7, 28 e 91 dias). Os resultados da Etapa 1 mostraram que, para todas as misturas investigadas, houve elevação da penetração de cloretos e da absorção de água com o aumento da intensidade do carregamento e da relação água/cimento dos concretos. Também foi observado a existência de um processo de microfissuração causado pela ação dos pré-carregamentos dos concretos com pouca idade. Os melhores desempenhos foram obtidos para as misturas com cimentos pozolânicos e não submetidas ao carregamento. Os resultados observados na Etapa 2 mostraram que o aumento do período de cura dos concretos refletiu positivamente nos resultados dos ensaios mecânicos e de durabilidade. Nessa etapa, também foram realizados ensaios microestruturais complementares que permitiram observar que a continuidade da cura promoveu uma recuperação parcial das microfissuras (self-healing) nos concretos. No entanto, nem todas foram fechadas. Constatou-se que as magnitudes das microfissuras remanescentes eram tal que poderiam se tornar um caminho preferencial para a entrada de íons cloreto nos concretos. Conclui-se que todos os concretos analisados apresentaram a mesma tendência de comportamento, de redução da entrada de íons cloreto com o aumento do período de cura. No entanto, o diferencial dos resultados foi notado na intensidade dos valores observados, significantemente reduzidos para os cimentos pozolânicos. / The rationalization and industrialization of the construction promoted deep changes in the constructive process and on the management techniques in Brazil. Most of the construction companies look for solutions that allow it to increase the speed of the constructions to ensure competitiveness on the market, such as the reduction on the time of structure execution, as well as the period of scores and anticipating the beginning of the masonry building. The early removal of the scores put the structure in an early loading without giving enough time to part of the cement hydration reactions happen, starting the concrete micro cracking process. Consequently, the instantaneous and slow deformations tend to increase and hence, pathologies may occur with greater intensity. This work researches the influence of early loading, by axial compression, in the durability of different types of concrete. The experimental program was implemented in two stages. The first stage investigated the influence of the micro cracking caused by pre loading on the durability of concretes produced with three different types of cement classified based on the Brazilian standards (CPV-ARI, CPIV RS and CPII Z) and three water/cement ratios (0.35, 0.50 and 0.70). The samples loading were realized in laboratory at the ages of 1, 3 and 7 days. Two reference samples were loaded until the limit, for each age of loading, and according to this average value of loading the percentage of loading to be applied on the samples in order to perform the durability tests were calculated (25%, 50% and 75%). The samples were placed in humid chamber for 28 days. After the cure period the samples were tested to Chloride ions penetration and water capillary absorption. The second stage of the experimental program investigated the influence of prolonged healing in the recovery of the damage caused by the concrete loading at early ages (microcracks). Concretes were produced with two types of cement (CPV-ARI and CPIV) and a water/cement ratio of 0,50. Part of the concrete received preload 75% of the tensile strength at age 3 days and some remained intact to serve as reference. The mechanical and durability tests were performed over time (3, 7, 28 and 91 days). The results of the first stage of the experimental program demonstrated that, for all the cements the increasing of the chloride penetration and water absorption is directly related with the increasing of the pre loading applied, to the increasing of the water/cement ratio on the mixture and the reduction of the age of the pre loading.The results obtained in Stage-1 confirmed the existence of a microcracking process caused by the action of the preload concrete at a young age. The best performances were observed for mixtures with pozzolan cement and not subjected to loading. The continued healing promoted a partial recovery of microcracks, verified by scanning electron microscopy images (SEM). However, not all were closed. It was found that the magnitude of the remaining microcracks were such that it could become a preferred path for the entry of chloride ions in concrete. All examined concrete showed the same trend behavior, reduction of the entrance of chloride ions with increasing curing period. However, the spread of results was noticed in the intensity of the observed values, significantly reduced for pozzolanic cements.
90

O uso da pressão expiratória positiva durante o desmame da ventilação mecânica : uma comparação com os métodos de pressão suporte e tubo T. / Positive expiratory pressure as a method for mechanical ventilation weaning: a comparison between the pressure support and T-tube methods

Rieder, Marcelo de Mello January 2004 (has links)
Introdução: O uso da pressão expiratória positiva na via aérea (EPAP) não é sugerido como técnica de desmame. O EPAP pode previnir o colapso das vias aéreas durante a expiração. Objetivo: O objetivo deste trabalho é verificar se a utilização da pressão expiratória positiva na via aérea (EPAP) apresenta benefícios na redução da hiperinsuflação dinâmica com redução do trabalho respiratório e melhora da oxigenação em pacientes submetidos ao processo de desmame da ventilação mecânica. Material e Métodos: Quarenta pacientes submetidos à ventilação mecânica por um período maior que 48 horas em 2 unidades de terapia intensiva foram avaliados prospectivamente em um estudo randomizado controlado cruzado. Todos os pacientes foram submetidos métodos de ventilação de pressão de suporte (PSV), tubo-t e EPAP, durante 30 minutos, com um período de descanso de 30 minutos entre cada método. Os pacientes foram monitorizados pelo VenTrack (Novametrix, EUA). As variáveis estudadas, mensuradas no minuto 1, 15 e 30, foram: PEEP intínseca (PEEPi), trabalho respiratório (WOBtotal), frequência respiratória (f), volume de ar corrente (Vt) e saturação periférica de oxigênio (SaO2). A amostra geral foi analisada e dividida em subgrupos DPOC (n= 14) e não-DPOC (n=26), traqueostomizados (n=15) e não-traqueostomizados (n=25). As comparações foram feitas pela Análise de Variância (ANOVA) e teste-t. O nível de significância foi de 95%. Resultados: PEEPi DPOC e não-DPOC minuto 1 (0,014 + 0,03 versus 0,17 + 0,38 cmH2O) e minuto 15 (0,042 + 0,13 versus 0,41 + 0,78 cmH2O) (p<0,05). No subgrupo não-traqueo, nos métodos de PSV15 (0,26 + 0,5 cm H2O) e EPAP15 (0,02 + 0,07 cm H2O), assim como PSV 30 (0,21 + 0,4 cm H2O) e EPAP 30 (0,02 + 0,1 cm H2O) (p<0,05). Para traqueo vs não-traqueo, no método EPAP minuto 1 (PEEPi traqueo 0,58 + 0,94 cm H2O; PEEPi não-traqueo 0,08 + 0,28 cmH2O) e minuto 15 (PEEPi traqueo 0,91 + 2,06 cm H2O; PEEPi não-traqueo 0,02 + 0,07 cmH2O) (p<0,05). Em relação ao WOBtotal houve um aumento significativo no método EPAP em relação ao tubo-t na análise geral da amostra (p<0,05). A f mostrou-se maior no método EPAP para o subgrupo não-DPOC e não-traqueo (minutos 1, 15 e 30). A SaO2 foi maior no subgrupo PSV quando comparada com tubo-t na análise geral da amostra, (p<0,05) Conclusões: A EPAP não demonstrou redução na PEEPi na análise geral da amostra, subgrupo DPOC, não-DPOC e traqueostomizados. Houve redução na PEEPi no grupo não-traqueostomizados. Houve aumento do WOBtotal com o uso da EPAP. Neste estudo a EPAP não demonstrou vantagens em relação aos outros métodos. / Introduction: The use of expiratory positive airway pressure was not suggested as a weaning technique.The EPAP can prevent the airway collapse during expiration. Goal: This study aims to verify whether use of positive expiratory pressure in airways assists in the reduction of dynamic hyperinsufflation, with reduction of work of breathing and improvement of oxygenation in patients undergoing weaning from mechanical ventilation. Material and Methods: Forty patients who need mechanical ventilation for more than 48 hours in 2 intensive care units were evaluetad in a randomized crossover study. All patients were submitted to pressure support ventilation (PSV), t-tube and EPAP method, during 30 minutes, with a rest time of 30 minutes between each method. They were monitored by VenTrack (Novametrix, EUA). All examined variables measured in time 1, 15 and 30, were: intrinsic PEEP (PEEPi), work of breathing (WOBtotal), respiratory rate (f), tidal volume (Vt) and arterial oxygen saturation (SaO2). A general analysis of the entire sample (n=40) was performed and divided in COPD (n= 14) and non-COPD subgroups (n=26), tracheostomized (n=15) and non-tracheostomized subgroups (n=25). Comparison were done by one way analysis (ANOVA) and t-test. The level of significance was 95%. Results: PEEPi COPD and non-COPD time 1 (0.014 + 0.03 versus 0.17 + 0.38 cmH2O) and time 15 (0.042 + 0.13 versus 0.41 + 0.78 cmH2O) (p<0.05). For non-tracheo subgroup, in PSV15 (0.26 + 0.5 cm H2O) and EPAP15 (0,02 + 0.07 cm H2O) methods, likewise PSV 30 (0.21 + 0.4 cm H2O) and EPAP 30 (0.02 + 0.1 cm H2O) methods (p<0.05). For tracheo vs non-tracheo, in EPAP time 1 (PEEPi tracheo 0.58 + 0.94 cm H2O; PEEPi non-tracheo 0.08 + 0.28 cmH2O) and time 15 (PEEPi tracheo 0.91 + 2.06 cm H2O; PEEPi non-tracheo 0.02 + 0.07 cmH2O) (p<0.05). Differences found demonstrated greater work of breathing in EPAP when compared to t-tube in all groups (p<0.05). Respiratory rate was significantly higher in EPAP method in the non-COPD and non-tracheo subgroup (time 1, 15 e 30). The SaO2 was higher in the PSV subgroup comparing with t-tube in the entire sample (p<0.05). Conclusions: The EPAP did not showed reduction in PEEP in the entire sample analysis, COPD , non-COPD and tracheostomized subgroups. There was a reduction in PEEPi in non-tracheostomized group. There was an increase in WOBtotal with the use of EPAP. In this study the EPAP did not show any advantage among the others methods.

Page generated in 0.0401 seconds