• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 39
  • Tagged with
  • 39
  • 26
  • 18
  • 17
  • 16
  • 15
  • 11
  • 10
  • 9
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estudo das condições de hidrólise de álcoois primários sulfatados. / A study on the susceptibility to acid-catalysed hydrolysis of primary alcohol ether sulfates in concentrated aqueous mixtures.

Oliveira, Maria Rita Perez de 04 April 2011 (has links)
Álcoois primários sulfatados de cadeia longa, usualmente na forma de sais de sódio, são tensoativos de grande interesse comercial utilizados em diversas formulações de higiene pessoal e limpeza doméstica. Eles são produzidos comercialmente através da reação de álcoois etoxilados com trióxido de enxofre seguida de imediata neutralização com hidróxido de sódio. O produto formado é uma solução neutra de álcool primário etoxilado sulfatado em água. Sabe-se que a armazenagem desse produto por longos períodos de tempo em temperaturas elevadas pode levar à hidrólise completa, mas, em condições normais de uso e temperatura ambiente é esperado que o produto seja resistente à hidrólise. No entanto observou-se que algumas amostras comerciais de lauril éter sulfato de sódio que foram estocadas por diferentes períodos de tempo em frascos fechados à temperatura ambiente sofreram hidrólise em intervalos de tempo relativamente curtos. Isso leva à hipótese de que o comportamento de hidrólise seria influenciado por outras variáveis além da temperatura e do tempo de estocagem. O presente trabalho consistiu em identificar as variáveis de maior impacto na reação de hidrólise por meio de experimentos planejados. O teor de ativos foi acompanhado ao longo da reação para avaliar o efeito da presença de eletrólitos, de material insulfatado, em diferentes temperaturas, variando-se o pH inicial por meio da adição de ácido clorídrico. O comportamento da reação de hidrólise observado foi compatível com aquele descrito na literatura para o dodecil sulfato de sódio. A hidrólise apresentou-se como sendo autocatalítica, com a aceleração da taxa de reação provavelmente causada pela presença de íons hidrogênio liberados na reação. Foi possível identificar que as variáveis de maior efeito na reação foram: pH inicial, o teor de cloreto de sódio e a temperatura. O modelo de troca iônica em pseudo-fase foi utilizado para o tratamento dos resultados experimentais e mostrou-se adequado tendo sido, portanto, utilizado para prever o comportamento de estabilidade do produto à temperatura ambiente e nas condições em que o produto é normalmente comercializado. Um modelo empírico de redes neurais foi desenvolvido com sucesso para prever o comportamento do pH ao longo do tempo para as condições estudadas. / Long-chain primary alkyl sulfuric acids, usually as their sodium salts, are important commercial surfactants used in a large number of household and personal care formulations. They are commercially produced by treatment of mixtures of ethoxylated fatty alcohols with sulfur trioxide followed by immediate neutralization with sodium hydroxide, a neutral aqueous mixture of sodium primary alkyl ether sulfate is obtained. It is known that prolonged storage of the material at elevated temperature can lead to complete hydrolysis but under normal use and typical environmental conditions the product is expected to be resistant to hydrolysis. In spite of that it has been observed that some commercial samples of sodium lauryl ether sulfate stored for different periods of time in sealed containers at room temperature have undergone hydrolysis in a relatively short period of time which leads to the hypothesis that the hydrolysis behavior would be strongly influenced by variables other than temperature and storage time. The present work consisted of identifying the process variables with the most significant effect on the acid hydrolysis by using experimental design. The rate of hydrolysis has been followed acidimetrically to evaluate the effect of electrolytes as well as the concentration of unsulfated matter at different temperatures, over a wide initial pH range, under the presence of added hydrochloric acid. The pattern of kinetic behaviour observed was broadly the same as previously described for the sodium dodecyl sulfate. The hydrolysis presented the characteristic autocatalytic form, the catalysis presumably arising from the production of hydrogen sulfate ions. It was possible to observe that the most significant effects on the rate of hydrolysis were the initial pH, the total amount of sodium chloride and the temperature. The results were also discussed in terms of the ion-exchange pseudophase model of the micelle reaction. Accordingly to the fitting of parameters that was carried out it is possible to conclude that the pseudo-phase ion-exchange theory is found to account satisfactorily for the results reported and it was used to predict the stability behavior of the product at room temperature and under normal commercial conditions. A neural network based model was also successfully developed in order to predict the pH behavior in the conditions studied.
32

Estudo das condições de hidrólise de álcoois primários sulfatados. / A study on the susceptibility to acid-catalysed hydrolysis of primary alcohol ether sulfates in concentrated aqueous mixtures.

Maria Rita Perez de Oliveira 04 April 2011 (has links)
Álcoois primários sulfatados de cadeia longa, usualmente na forma de sais de sódio, são tensoativos de grande interesse comercial utilizados em diversas formulações de higiene pessoal e limpeza doméstica. Eles são produzidos comercialmente através da reação de álcoois etoxilados com trióxido de enxofre seguida de imediata neutralização com hidróxido de sódio. O produto formado é uma solução neutra de álcool primário etoxilado sulfatado em água. Sabe-se que a armazenagem desse produto por longos períodos de tempo em temperaturas elevadas pode levar à hidrólise completa, mas, em condições normais de uso e temperatura ambiente é esperado que o produto seja resistente à hidrólise. No entanto observou-se que algumas amostras comerciais de lauril éter sulfato de sódio que foram estocadas por diferentes períodos de tempo em frascos fechados à temperatura ambiente sofreram hidrólise em intervalos de tempo relativamente curtos. Isso leva à hipótese de que o comportamento de hidrólise seria influenciado por outras variáveis além da temperatura e do tempo de estocagem. O presente trabalho consistiu em identificar as variáveis de maior impacto na reação de hidrólise por meio de experimentos planejados. O teor de ativos foi acompanhado ao longo da reação para avaliar o efeito da presença de eletrólitos, de material insulfatado, em diferentes temperaturas, variando-se o pH inicial por meio da adição de ácido clorídrico. O comportamento da reação de hidrólise observado foi compatível com aquele descrito na literatura para o dodecil sulfato de sódio. A hidrólise apresentou-se como sendo autocatalítica, com a aceleração da taxa de reação provavelmente causada pela presença de íons hidrogênio liberados na reação. Foi possível identificar que as variáveis de maior efeito na reação foram: pH inicial, o teor de cloreto de sódio e a temperatura. O modelo de troca iônica em pseudo-fase foi utilizado para o tratamento dos resultados experimentais e mostrou-se adequado tendo sido, portanto, utilizado para prever o comportamento de estabilidade do produto à temperatura ambiente e nas condições em que o produto é normalmente comercializado. Um modelo empírico de redes neurais foi desenvolvido com sucesso para prever o comportamento do pH ao longo do tempo para as condições estudadas. / Long-chain primary alkyl sulfuric acids, usually as their sodium salts, are important commercial surfactants used in a large number of household and personal care formulations. They are commercially produced by treatment of mixtures of ethoxylated fatty alcohols with sulfur trioxide followed by immediate neutralization with sodium hydroxide, a neutral aqueous mixture of sodium primary alkyl ether sulfate is obtained. It is known that prolonged storage of the material at elevated temperature can lead to complete hydrolysis but under normal use and typical environmental conditions the product is expected to be resistant to hydrolysis. In spite of that it has been observed that some commercial samples of sodium lauryl ether sulfate stored for different periods of time in sealed containers at room temperature have undergone hydrolysis in a relatively short period of time which leads to the hypothesis that the hydrolysis behavior would be strongly influenced by variables other than temperature and storage time. The present work consisted of identifying the process variables with the most significant effect on the acid hydrolysis by using experimental design. The rate of hydrolysis has been followed acidimetrically to evaluate the effect of electrolytes as well as the concentration of unsulfated matter at different temperatures, over a wide initial pH range, under the presence of added hydrochloric acid. The pattern of kinetic behaviour observed was broadly the same as previously described for the sodium dodecyl sulfate. The hydrolysis presented the characteristic autocatalytic form, the catalysis presumably arising from the production of hydrogen sulfate ions. It was possible to observe that the most significant effects on the rate of hydrolysis were the initial pH, the total amount of sodium chloride and the temperature. The results were also discussed in terms of the ion-exchange pseudophase model of the micelle reaction. Accordingly to the fitting of parameters that was carried out it is possible to conclude that the pseudo-phase ion-exchange theory is found to account satisfactorily for the results reported and it was used to predict the stability behavior of the product at room temperature and under normal commercial conditions. A neural network based model was also successfully developed in order to predict the pH behavior in the conditions studied.
33

Extração líquido-líquido de ácido clavulânico empregando sistemas micelares mistos de duas fases aquosas / Liquid-liquid extraction of clavulanic acid employing two-phase aqueous mixed micellar systems

Valéria de Carvalho Santos 06 March 2009 (has links)
O ácido clavulânico é um potente inibidor de β-lactamases utilizado como terapêutico em associação à amoxicilina. O processo industrial de obtenção envolve o cultivo bacteriano em processo descontínuo, enquanto que a sua purificação é realizada, principalmente, por processos de extração líquido-líquido com solventes orgânicos e etapas cromatográficas. Assim, métodos alternativos como a purificação empregando sistemas micelares de duas fases aquosas (SMDFA), os quais oferecem um ambiente hidrofóbico e hidrofílico que possibilita seletividade na partição de biomoléculas de acordo com sua hidrofobicidade, são de grande interesse. Neste trabalho estudou-se a viabilidade da utilização de sistema micelar misto (não-iônico/aniônico) de duas fases aquosas formados pelos tensoativos não-iônico Triton X-114 e aniônico AOT na extração do ácido clavulânico proveniente de cultivo submerso de Streptomyces clavuligerus em processo descontínuo. A estabilidade do ácido clavulânico em relação ao pH, sais e suas concentrações, temperatura e aos tensoativos foi investigada visando limitar as regiões a serem estudadas nas extrações. Determinou-se ainda o ponto névoa dos sistemas Triton X-114/Tampão e Triton X-114/AOT/Tampão em diferentes condições, bem como, estudos de migração da biomolécula para as fases e do tempo necessário para o equilíbrio do sistema. A partir destas investigações iniciais, foram definidos os níveis das variáveis: concentração de AOT (0,50, 0,75 e 1,00 mM), Triton X-114 (1, 3 e 5% m/m), NaCl (0, 0,05 e 0,10 M) e temperatura (24, 26 e 28°C), cujas influências sobre o coeficiente de partição (KAC) e recuperação da biomolécula na fase diluída (nAC) foram investigadas através de um planejamento fatorial. A análise estatística e o modelo matemático obtido a partir dos resultados para KAC revelou ser possível obterem-se KAC≈ 1,65 e nAC≈ 71,58%. No entanto, a análise estatística empregando nAC como resposta apontou condições experimentais desprovidas de significado físico-químico. Em experimentos seriados realizados com Triton X-114 3% m/m, Tampão Mcllavine pH 6,5 e adição gradual de AOT, um aumento da concentração deste tensoativo levou a maiores KAC e Balanço de massa (BMAC)≈ 85%. Desta forma é possível concluir que o sistema micelar misto de duas fases aquosas proporciona baixa perda da biomolécula e partição para a fase diluída, que é uma vantagem devido a menores problemas em uma etapa subsequente de purificação. / Clavulanic acid is a potent inhibitor of β-lactamases that is used as a therapeutic in conjunction with amoxicillin. Its industrial process of production involves bacterial growing in a batch process, while its purification is carried out mainly by process of liquid-liquid extraction with organic solvents and chromatographic steps. Thus, alternative methods like the purification employing two-phase aqueous micellar systems, which offer both hydrophobic and hydrophilic environments to solute species and allow selectivity in partitioning depending on the hydrophobicity of biomolecules, are of great concern. This work studied the feasibility of using two-phase aqueous mixed (nonionic/anionic) micellar systems formed by nonionic surfactant Triton X-114 and anionic surfactant AOT to extract clavulanic acid from broths fermented by Streptomyces clavuligerus in batch process. The stability of clavulanic acid at different values of pH, salts and their concentration, temperature and in the presence of different surfactants was investigated so as to limit the areas to be submitted to further studies. The cloud-point of the systems Triton X-114/Buffer and Triton X-114/AOT/Buffer was also determined under different conditions, and studies were performed on partitioning the biomolecule between the phases and the time needed to balance of the system. From these initial investigations the following levels of the variables were defined: concentration of AOT (0.50, 0.75, and 1.00 mM), Triton X-114 (1, 3 and 5% w/w), NaCl (0, 0.05 and 0.10 M) and temperature (24, 26 and 28°C), whose influences on the partition coefficient (KCA) and yield in the top phase (nCA) were investigated using factorial design. Statistical analysis and the mathematical model derived from the results allowed obtaining KCA≈ 1.65 e nCA≈ 71.58%. However, the statistical analysis using the response nCA indicated experimental conditions devoid of any physico-chemical meaning. In serial experiments performed with Triton X-114 3% w/w, Mcllvaine buffer at 6.5 pH and gradual addition of AOT, an increase in the concentration of anionic surfactant led to higher KCA and mass balance (BMCA≈ 85%). Thus, is possible conclude that the two-phase aqueous mixed micellar system provides low loss and partition to dilute phase, which is an advantage because it implies less problems in a subsequent step of purification.
34

Extração líquido-líquido de ácido clavulânico empregando sistemas micelares mistos de duas fases aquosas / Liquid-liquid extraction of clavulanic acid employing two-phase aqueous mixed micellar systems

Santos, Valéria de Carvalho 06 March 2009 (has links)
O ácido clavulânico é um potente inibidor de β-lactamases utilizado como terapêutico em associação à amoxicilina. O processo industrial de obtenção envolve o cultivo bacteriano em processo descontínuo, enquanto que a sua purificação é realizada, principalmente, por processos de extração líquido-líquido com solventes orgânicos e etapas cromatográficas. Assim, métodos alternativos como a purificação empregando sistemas micelares de duas fases aquosas (SMDFA), os quais oferecem um ambiente hidrofóbico e hidrofílico que possibilita seletividade na partição de biomoléculas de acordo com sua hidrofobicidade, são de grande interesse. Neste trabalho estudou-se a viabilidade da utilização de sistema micelar misto (não-iônico/aniônico) de duas fases aquosas formados pelos tensoativos não-iônico Triton X-114 e aniônico AOT na extração do ácido clavulânico proveniente de cultivo submerso de Streptomyces clavuligerus em processo descontínuo. A estabilidade do ácido clavulânico em relação ao pH, sais e suas concentrações, temperatura e aos tensoativos foi investigada visando limitar as regiões a serem estudadas nas extrações. Determinou-se ainda o ponto névoa dos sistemas Triton X-114/Tampão e Triton X-114/AOT/Tampão em diferentes condições, bem como, estudos de migração da biomolécula para as fases e do tempo necessário para o equilíbrio do sistema. A partir destas investigações iniciais, foram definidos os níveis das variáveis: concentração de AOT (0,50, 0,75 e 1,00 mM), Triton X-114 (1, 3 e 5% m/m), NaCl (0, 0,05 e 0,10 M) e temperatura (24, 26 e 28°C), cujas influências sobre o coeficiente de partição (KAC) e recuperação da biomolécula na fase diluída (nAC) foram investigadas através de um planejamento fatorial. A análise estatística e o modelo matemático obtido a partir dos resultados para KAC revelou ser possível obterem-se KAC≈ 1,65 e nAC≈ 71,58%. No entanto, a análise estatística empregando nAC como resposta apontou condições experimentais desprovidas de significado físico-químico. Em experimentos seriados realizados com Triton X-114 3% m/m, Tampão Mcllavine pH 6,5 e adição gradual de AOT, um aumento da concentração deste tensoativo levou a maiores KAC e Balanço de massa (BMAC)≈ 85%. Desta forma é possível concluir que o sistema micelar misto de duas fases aquosas proporciona baixa perda da biomolécula e partição para a fase diluída, que é uma vantagem devido a menores problemas em uma etapa subsequente de purificação. / Clavulanic acid is a potent inhibitor of β-lactamases that is used as a therapeutic in conjunction with amoxicillin. Its industrial process of production involves bacterial growing in a batch process, while its purification is carried out mainly by process of liquid-liquid extraction with organic solvents and chromatographic steps. Thus, alternative methods like the purification employing two-phase aqueous micellar systems, which offer both hydrophobic and hydrophilic environments to solute species and allow selectivity in partitioning depending on the hydrophobicity of biomolecules, are of great concern. This work studied the feasibility of using two-phase aqueous mixed (nonionic/anionic) micellar systems formed by nonionic surfactant Triton X-114 and anionic surfactant AOT to extract clavulanic acid from broths fermented by Streptomyces clavuligerus in batch process. The stability of clavulanic acid at different values of pH, salts and their concentration, temperature and in the presence of different surfactants was investigated so as to limit the areas to be submitted to further studies. The cloud-point of the systems Triton X-114/Buffer and Triton X-114/AOT/Buffer was also determined under different conditions, and studies were performed on partitioning the biomolecule between the phases and the time needed to balance of the system. From these initial investigations the following levels of the variables were defined: concentration of AOT (0.50, 0.75, and 1.00 mM), Triton X-114 (1, 3 and 5% w/w), NaCl (0, 0.05 and 0.10 M) and temperature (24, 26 and 28°C), whose influences on the partition coefficient (KCA) and yield in the top phase (nCA) were investigated using factorial design. Statistical analysis and the mathematical model derived from the results allowed obtaining KCA≈ 1.65 e nCA≈ 71.58%. However, the statistical analysis using the response nCA indicated experimental conditions devoid of any physico-chemical meaning. In serial experiments performed with Triton X-114 3% w/w, Mcllvaine buffer at 6.5 pH and gradual addition of AOT, an increase in the concentration of anionic surfactant led to higher KCA and mass balance (BMCA≈ 85%). Thus, is possible conclude that the two-phase aqueous mixed micellar system provides low loss and partition to dilute phase, which is an advantage because it implies less problems in a subsequent step of purification.
35

Olmesartana medoxomila : validação de metodologia analítica, avaliação biofarmacêutica e análise polimórfica / Olmesartan medoxomil: validation of analytical methodology, biopharmaceutical evaluation, and polymorphic analysis

Bajerski, Lisiane January 2010 (has links)
O pró-fármaco olmesartana medoxomila (OLM) é um anti-hipertensivo representante da classe dos bloqueadores seletivos dos receptores da angiotensina II (BRA). No Brasil, encontra-se disponível sob a forma de comprimidos revestidos (Benicar®). Foi aprovado pelo FDA em 2002. Não existe monografia disponível para este fármaco em nenhum código oficial. Desse modo, este trabalho objetivou o desenvolvimento de métodos analíticos para quantificação da OLM na substância química de referência (SQR) e forma farmacêutica, estabelecer a cinética de dissolução in vitro para os comprimidos revestidos deste fármaco e por fim investigar a presença de diferentes estruturas polimórficas da SQR deste anti-hipertensivo. A determinação da faixa de fusão, a espectrofotometria na região do infravermelho (IV), assim como a espectroscopia de ressonância magnética nuclear (RMN) de 1H e 13C permitiram a identificação da SQR. Os métodos por espectrofotometria na região do ultravioleta (UV), cromatografia em camada delgada (CCD), cromatografia a líquido de alta eficiência (CLAE) e cromatografia capilar eletrocinética micelar (MECC) foram utilizados para análise qualitativa do fármaco no produto acabado. A determinação quantitativa foi realizada através do desenvolvimento e validação de método indicativo da estabilidade por CLAE e MECC, avaliando-se os parâmetros descritos pelas guias de validação como: especificidade, robustez, linearidade, limites de detecção e quantificação, precisão e exatidão. Determinou-se ainda, a intercambialidade dos mesmos, através de análise estatística por ANOVA (p = 0,05), e comprovou-se que ambos podem ser utilizados para análise qualitativa e quantitativa da OLM em matéria-prima e produto acabado. O teste de dissolução foi desenvolvido e validado de acordo com o guia proposto pelo USP Fórum, utilizando como meio de dissolução 900 ml de uma solução a 0,5% (p/V) de lauril sulfato de sódio pH 6,8, a 37 ± 0,5 °C, pás a 50 rpm e quantificação por CLAE e espectrofotometria na região do UV. A análise do teor de OLM dissolvida, realizada por ambos os métodos, não apresentou diferença estatística (p > 0,05). Os perfis de dissolução do Benicar®, medicamento referência, e do Olmetec®, outra formulação disponível no mercado, foram considerados semelhantes, após aplicação do método modelo-independente (f1 e f2) e eficiência de dissolução. Avaliou-se, também, a cinética de dissolução de ambas as formulações através da aplicação de métodos modelo-dependentes. Os perfis de dissolução do Benicar® e Ometec® foram descritos pelos modelos propostos por Hixson-Crowell e de ordem zero, respectivamente. Os valores calculados para t50% e t80%, obtidos através da aplicação da equação de ordem zero, foram semelhantes aos valores experimentais encontrados no perfil de dissolução de ambos os produtos. As técnicas de espectrofotometria por reflexão difusa no IV com transformada de Fourier (ATRFTIR), difração de raios-X de pó (XRPD), calorimetria exploratória diferencial (DSC), termogravimetria (TGA) e microscopia eletrônica de varredura (MEV) permitiram a identificação de uma forma amorfa e outra polimórfica da SQR da OLM, diferentes daquela descrita na literatura. Logo, de acordo com os resultados obtidos, todos os métodos propostos podem ser utilizados para no controle de qualidade da OLM em SQR e produto acabado. / The prodrug olmesartan medoxomil (OLM) is a selective angiotensin II receptor blocker (ARB). In Brazil, it is available as coated tablets (Benicar®). It was approved by FDA in 2002. There is no monograph available for this drug in any official code. According to this, the main purpose of this study was to develop a quality control analytical methodology for OLM in bulk material and dosage form, to establish in vitro dissolution kinetic for OLM coated tablets, and to investigate the crystalline behavior of OLM bulk material. The investigation of melting range and application of techniques such as infrared spectrophotometry (IR), as well as the 1H and 13C nuclear magnetic resonance (NMR) spectroscopy were used to identify OLM. Ultraviolet (UV) spectrophotometry, thin-layer chromatography (TLC), highperformance liquid chromatography (LC) and micellar electrokinetic chromatography (MEKC) were used for qualitative analysis of the drug in coated tablets. The quantitative determination was carried out through the development and validation of a stability-indicating LC and MEKC methods, evaluating the parameters described in the guidelines such as: specificity, robustness, linearity, detection and quantitation limits, precision, and accuracy. The results were compared statistically by ANOVA (p = 0.05), and no difference was found between them for both bulk material and coated tablets. A dissolution test was developed and validated according to the guideline proposed by the USP Forum, using 900 ml of dissolution medium containing 0.5% of sodium lauryl sulfate (w/V) pH 6.8, at 37 ± 0.5 °C, paddle at 50 rpm, and quantitation by LC and UV spectrophotometry. The resulting dissolution profiles did not show statistical difference (p > 0.05) between methods. The dissolution profiles of Benicar®, reference formulation, and Olmetec®, another commercial formulation available, were considered similar, using model independent (f1, f2, and dissolution efficiency) methods. The dissolution kinetic of both formulations, using model dependent approaches, revealed that Benicar® followed the Hixson-Crowell model, while Olmetec® the zero-order model. The calculated values of t50% and t80%, obtained from zero-order equation, were similar of experimental values found in the dissolution profile for both products. The attenuated total reflectance Fourier transformed infrared (ATR-FTIR) spectrophotometry, along with differential scanning calorimetry (DSC), thermogravimetry (TG), X-ray powder diffraction (XRPD), and scanning electron microscopy (SEM) allowed to identify one amorphous and other polymorphic forms of OLM. According to the obtained results, all proposed methods could be used in the quality control of OLM bulk material and coated tablets.
36

[en] MICELLAR LIQUID CHROMATOGRAPHY WITH FLUORIMETRIC DETECTION FOR THE DETERMINATION OF SIX B-CARBOLINE ALKALOIDS AND GALANTAMINE IN THE PRESENCE OF ITS MAJOR METABOLITES / [pt] DESENVOLVIMENTO DE MÉTODOS UTILIZANDO CROMATOGRAFIA LÍQUIDA MICELAR (MLC) COM DETECÇÃO FLUORIMÉTRICA PARA A DETERMINAÇÃO DE SEIS ALCALOIDES B-CARBOLINAS E PARA GALANTAMINA EM PRESENÇA DOS SEUS PRINCIPAIS METABÓLITOS

ANA PAULA LAMOUNIER 08 July 2016 (has links)
[pt] Métodos baseados na cromatografia líquida micelar (MLC) com detecção fluorimétrica foram desenvolvidos para dois estudos de caso. No primeiro deles, seis B-carbolinas (harmol, harmalol, harmane, norharmane, harmine e harmaline) foram plenamente separadas de modo a se aplicar o método para a determinação dos alcaloides em formulações de Passiflora incarnata L., extrato seco de Passiflora alata Dryander e em urina. A separação foi realizada em coluna cromatográfica C18, utilizando fase móvel tamponada (pH 8,0) contendo 220 mmol L-1 de dodecilsulfato de sódio (SDS)/acetonitrila (97/3 por cento v/v). A detecção fluorimétrica permitiu que se atingissem limites de detecção (LOD) abaixo de 3,6 ng g-1 com repetibilidade e precisão intermediária entre 0,1 e 5 por cento. As incertezas combinadas associadas à concentração das B-carbolinas ficaram entre 1 e 9 por cento. O método proposto foi comparado ao método baseado na cromatografia eletrocinética micelar (MEKC) com detecção absorciométrica e os resultados com MLC se mostraram superiores do ponto de vista da capacidade de detecção (por serem os alcaloides naturalmente muito fluorescentes) e de recuperação. Para as amostras de fitoterápicos, o harmol foi quantificado tanto nas amostras de medicamento de Passiflora incarnata quanto em urina de voluntário após a administração de fitoterápico. O harmine foi detectado apenas na amostra de medicamento. Os alcaloides norharmane, harmine e harmaline foram identificados no chá misto de Maracujá, no qual continha em sua composição extrato seco de Passiflora alata Dryander. Na segunda abordagem, um método por MLC foi desenvolvido para a determinação de galantamina e de seus principais metabólitos (N-desmetil galantamina, O-desmetil galantamina, epigalantamina e N-óxido galantamina). A separação da galantamina e dos metabólitos foi feita utilizando coluna cromatográfica C18 com porosidade de 300 angstroms e fase móvel constituída de tampão (pH 5,0) contendo 25 mmol L-1 de SDS/acetonitrila (97/3 por cento v/v). A detecção fluorimétrica permitiu limites de detecção abaixo de 343 ng g-1, repetibilidade e precisão intermediária entre 2,2 e 4 por cento. As incertezas combinadas associadas à concentração de galantamina e dos metabólitos ficaram entre 0,3 e 11 por cento. Ensaios de recuperação foram realizados em amostra de urina fortificada com padrões da galantamina e metabólitos e os resultados obtidos ficaram entre de 91,4 e 114,8 por cento. A comparação entre o método por MLC e o método por cromatografia líquida de alta eficiência com fase reversa foram feitas com amostras de medicamento cujo princípio ativo era o hidrobrometo de galantamina. Os resultados dos teores de galantamina e as variâncias das medidas obtidas por ambos os métodos foram estatisticamente iguais. A sensibilidade da curva analítica obtida por MLC foi duas vezes maior do que a encontrada por cromatografia por fase reversa. Análises de urina de ratos coletadas após a administração do medicamento foram realizadas com o método proposto, sendo que a galantamina mais os metabólitos N-óxido galantamina e N-desmetil galantamina foram identificados nas amostras. Para melhor avaliar o efeito de amplificação de fluorescência da galantamina pelo ambiente organizado, experimentos foram feitos com a separação cromatográfica de fase reversa e com a adição de solução rica em micelas de SDS após a passagem do analito pela coluna cromatográfica. As condições de separação incluíram o uso de coluna cromatográfica C18, fase móvel constituída por tampão (pH 5,0) contendo 2 por cento de propano-2-ol (v/v)/ acetonitrila (80/20 por cento v/v). A solução micelar de SDS (100 mmol L-1), misturada à fase móvel após a coluna cromatográfica, foi preparada com a mesma composição da fase móvel. A sensibilidade da curva analítica de galantamina foi três vezes maior quando o meio micelar foi usado. O resultado prova que o ambiente micelar favorece a medição fluorimétrica de galantam / [en] Methods based on micellar liquid chromatography (MLC) with fluorimetric detection have been developed for two case studies. In the first, six B-carbolines (harmol, harmalol, harmane, norharmane, harmine and harmaline) were fully separated allowing the application of the method for the determination of these alkaloids in Passiflora incarnata L. formulations, in Passiflora alata Dryander dry extract and in urine. The chromatographic separation was performed on a C18 column using a buffered mobile phase consisting of disodium hydrogen phosphate (pH 8.0) containing 220 mmol L-1 of sodium dodecyl sulfate (SDS)/acetonitrile (97/3 percent v/v). The fluorimetric detection allowed limits of detection (LOD) below than 3.6 ng g-1 to be achieved with intermediary precision and repeatability between 0.1 and 5 percent. The calculated combined uncertainties of the concentration of B-carbolines were between 1 and 9 percent. The proposed method was compared with the method based on micellar electrokinetic chromatography (MEKC) with absortionmetric detection. The MLC results were superior from the viewpoint of the detection power (since they are very fluorescent alkaloids) and also in terms of recovery. The harmol was quantified in Passiflora incarnata phitotherapic samples and in urine collected from a voluntary after of the administration of herbal medicine. The harmine was detected only in the phitotherapic sample. The norharmane, harmine and harmaline alkaloids were identified in Passion Fruit tea, which contained dry extract of Passiflora alata Dryander. In the second approach, a method for MLC was developed for the determination of galantamine and its main metabolites (N-demethyl galantamine, O-demethyl galantamine, epigalantamine and N-oxide galantamine). The separation was performed using a C18 chromatography column with porosity of 300 angstroms and with mobile phase consisting of buffer (pH 5.0) containing SDS (25 mmol L-1)/acetonitrile (97/3 percent v/v). The fluorimetric detection enabled LOD below 343 ng g-1 with intermediate precision and repeatability between 2.2 and 4 percent. Combined uncertainties for concentration of galantamine and metabolites were between 0.3 and 11 percent. Recovery experiments were performed on urine samples fortified with galantamine standards and metabolites with results between 91.4 and 114.8 percent. A comparison between the proposed MLC method and reverse phase high performance liquid chromatography was made using medicine samples containing galantamine hydrobromide as the active principle. Galantamine levels and variances achieved with these methods were statistically equal. The analytical curve sensitivity by MLC was two times higher than that found with reverse phase high performance liquid chromatography. Analysis of rat urine, collected after the administration of the medicine, were performed with the proposed method enabling the identification of galantamine, N-oxide galantamine and N-demethyl galantamine. To better evaluate the fluorescence amplification effect of galantamine in the organized environment, experiments were made with conventional chromatographic separation and post-column addition of the aqueous solution rich in micelles. The separation conditions included the use of C18 chromatographic column, mobile phase consisting of buffer (pH 5.0) containing 2 percent of propan-2-ol (v/v)/acetonitrile (80/20 percent v/v). The micellar solution of SDS (100 mmol L-1), added after the chromatographic column, was prepared with the same composition of the mobile phase. The column temperature was 25 degrees C and the sample volume was 20 uL. The sensitivity of the analytical curve of galantamine was three times higher when the micellar solution was mixed, proving that the organized environment favors the galantamine fluorescence even at flow regime. Recoveries with or without post-column mixing with the micelle rich solution were between 97.5 and 102.2 percent.
37

Olmesartana medoxomila : validação de metodologia analítica, avaliação biofarmacêutica e análise polimórfica / Olmesartan medoxomil: validation of analytical methodology, biopharmaceutical evaluation, and polymorphic analysis

Bajerski, Lisiane January 2010 (has links)
O pró-fármaco olmesartana medoxomila (OLM) é um anti-hipertensivo representante da classe dos bloqueadores seletivos dos receptores da angiotensina II (BRA). No Brasil, encontra-se disponível sob a forma de comprimidos revestidos (Benicar®). Foi aprovado pelo FDA em 2002. Não existe monografia disponível para este fármaco em nenhum código oficial. Desse modo, este trabalho objetivou o desenvolvimento de métodos analíticos para quantificação da OLM na substância química de referência (SQR) e forma farmacêutica, estabelecer a cinética de dissolução in vitro para os comprimidos revestidos deste fármaco e por fim investigar a presença de diferentes estruturas polimórficas da SQR deste anti-hipertensivo. A determinação da faixa de fusão, a espectrofotometria na região do infravermelho (IV), assim como a espectroscopia de ressonância magnética nuclear (RMN) de 1H e 13C permitiram a identificação da SQR. Os métodos por espectrofotometria na região do ultravioleta (UV), cromatografia em camada delgada (CCD), cromatografia a líquido de alta eficiência (CLAE) e cromatografia capilar eletrocinética micelar (MECC) foram utilizados para análise qualitativa do fármaco no produto acabado. A determinação quantitativa foi realizada através do desenvolvimento e validação de método indicativo da estabilidade por CLAE e MECC, avaliando-se os parâmetros descritos pelas guias de validação como: especificidade, robustez, linearidade, limites de detecção e quantificação, precisão e exatidão. Determinou-se ainda, a intercambialidade dos mesmos, através de análise estatística por ANOVA (p = 0,05), e comprovou-se que ambos podem ser utilizados para análise qualitativa e quantitativa da OLM em matéria-prima e produto acabado. O teste de dissolução foi desenvolvido e validado de acordo com o guia proposto pelo USP Fórum, utilizando como meio de dissolução 900 ml de uma solução a 0,5% (p/V) de lauril sulfato de sódio pH 6,8, a 37 ± 0,5 °C, pás a 50 rpm e quantificação por CLAE e espectrofotometria na região do UV. A análise do teor de OLM dissolvida, realizada por ambos os métodos, não apresentou diferença estatística (p > 0,05). Os perfis de dissolução do Benicar®, medicamento referência, e do Olmetec®, outra formulação disponível no mercado, foram considerados semelhantes, após aplicação do método modelo-independente (f1 e f2) e eficiência de dissolução. Avaliou-se, também, a cinética de dissolução de ambas as formulações através da aplicação de métodos modelo-dependentes. Os perfis de dissolução do Benicar® e Ometec® foram descritos pelos modelos propostos por Hixson-Crowell e de ordem zero, respectivamente. Os valores calculados para t50% e t80%, obtidos através da aplicação da equação de ordem zero, foram semelhantes aos valores experimentais encontrados no perfil de dissolução de ambos os produtos. As técnicas de espectrofotometria por reflexão difusa no IV com transformada de Fourier (ATRFTIR), difração de raios-X de pó (XRPD), calorimetria exploratória diferencial (DSC), termogravimetria (TGA) e microscopia eletrônica de varredura (MEV) permitiram a identificação de uma forma amorfa e outra polimórfica da SQR da OLM, diferentes daquela descrita na literatura. Logo, de acordo com os resultados obtidos, todos os métodos propostos podem ser utilizados para no controle de qualidade da OLM em SQR e produto acabado. / The prodrug olmesartan medoxomil (OLM) is a selective angiotensin II receptor blocker (ARB). In Brazil, it is available as coated tablets (Benicar®). It was approved by FDA in 2002. There is no monograph available for this drug in any official code. According to this, the main purpose of this study was to develop a quality control analytical methodology for OLM in bulk material and dosage form, to establish in vitro dissolution kinetic for OLM coated tablets, and to investigate the crystalline behavior of OLM bulk material. The investigation of melting range and application of techniques such as infrared spectrophotometry (IR), as well as the 1H and 13C nuclear magnetic resonance (NMR) spectroscopy were used to identify OLM. Ultraviolet (UV) spectrophotometry, thin-layer chromatography (TLC), highperformance liquid chromatography (LC) and micellar electrokinetic chromatography (MEKC) were used for qualitative analysis of the drug in coated tablets. The quantitative determination was carried out through the development and validation of a stability-indicating LC and MEKC methods, evaluating the parameters described in the guidelines such as: specificity, robustness, linearity, detection and quantitation limits, precision, and accuracy. The results were compared statistically by ANOVA (p = 0.05), and no difference was found between them for both bulk material and coated tablets. A dissolution test was developed and validated according to the guideline proposed by the USP Forum, using 900 ml of dissolution medium containing 0.5% of sodium lauryl sulfate (w/V) pH 6.8, at 37 ± 0.5 °C, paddle at 50 rpm, and quantitation by LC and UV spectrophotometry. The resulting dissolution profiles did not show statistical difference (p > 0.05) between methods. The dissolution profiles of Benicar®, reference formulation, and Olmetec®, another commercial formulation available, were considered similar, using model independent (f1, f2, and dissolution efficiency) methods. The dissolution kinetic of both formulations, using model dependent approaches, revealed that Benicar® followed the Hixson-Crowell model, while Olmetec® the zero-order model. The calculated values of t50% and t80%, obtained from zero-order equation, were similar of experimental values found in the dissolution profile for both products. The attenuated total reflectance Fourier transformed infrared (ATR-FTIR) spectrophotometry, along with differential scanning calorimetry (DSC), thermogravimetry (TG), X-ray powder diffraction (XRPD), and scanning electron microscopy (SEM) allowed to identify one amorphous and other polymorphic forms of OLM. According to the obtained results, all proposed methods could be used in the quality control of OLM bulk material and coated tablets.
38

DRONEDARONA DESENVOLVIMENTO E VALIDAÇÃO DE METODOLOGIA PARA ANÁLISE DE COMPRIMIDOS REVESTIDOS / DRONEDARONE DEVELOPMENT AND VALIDATION OF METHODOLOGY FOR THE ANALYSIS OF FILM-COATED TABLETS

Marcolino, Ana Isa Pedroso 24 August 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Dronedarone is a new antiarrhythmic agent and amiodarone analogue developed to reduce the toxic effects related to amiodarone. Dronedarone was approved for the maintenance of the sinus rhythmic in adult patients with atrial fibrillation and to reduce the risk of hospitalization in these patients. It is commercially available as film-coated tablets. There are no official monographs in any pharmacopoeia or analytical methods described in the literature for the analysis of dronedarone in pharmaceutical dosage form or bulk form. In the present study, an analytical methodology was developed for the analysis of dronedarone in pharmaceutical dosage form and bulk form. The reversed-phase liquid chromatography method was performed using a Waters XBridge C18 column (250 mm × 4.6 mm). The mobile phase consisted of buffer solution pH 4.9 / acetonitrile (35:65, v/v), running at a flow rate of 1.0 mL/min, using photodiode array detector set at 289 nm. The chromatographic separation was obtained within 7.0 min and it was linear in the concentration range from 5.0 to 100.0 μg/mL (r = 0.9999). The spectrophotometric method was developed and validated and dronedarone was quantified at 289 nm, using methanol as diluent. The micellar electrokinetic method was also developed and validated, using nimesulide as internal standard. The analyses were performed on a fused-silica capillary (50 μm i.d.; effective length, 40 cm), using electrolyte solution consisted of 40 mm borate buffer and 50 mM SDS at pH 9.2, with detection by photodiode array detector set at 216 nm. The injection was performed using the hydrodynamic mode at 50 mbar for 7 s and a constant voltage of 28 kV was applied during analysis. The electrophoretic separation was obtained within 7.0 min and it was linear in the concentration range from 25 to 150 μg/mL (r = 0.9995). The procedures were validated evaluating parameters such as the specificity, linearity, precision, accuracy, limits of detection and quantitation and robustness, giving results within the acceptable range. The proposed methods were applied for the analysis of the pharmaceutical product, showing significant correlation between the results (p > 0.05). The spectrophotometric method was developed and validated using acetate buffer pH 4.5 as diluent and UV detection at 289 nm, which was applied to evaluate the dissolution test. The dissolution test was developed using 900 mL of acetate buffer pH 4.5 at 37°C, as dissolution medium, and paddle as apparatus at a stirring rate of 75 rpm. / A dronedarona é um novo agente antiarrítmico análogo à amiodarona, desenvolvido com o propósito de reduzir os efeitos adversos relacionados à amiodarona. Foi aprovado para a manutenção do ritmo cardíaco normal em pacientes com fibrilação atrial e, assim, reduzir os riscos de hospitalização. Comercialmente, encontra-se disponível na forma farmacêutica de comprimidos revestidos. Não há monografias descritas em farmacopeias ou métodos na literatura para análise de dronedarona em forma farmacêutica ou matéria-prima. No presente trabalho, foi desenvolvida metodologia para a avaliação de dronedarona em forma farmacêutica e matéria-prima. O método por cromatografia líquida em fase reversa foi realizado utilizando-se coluna Waters XBridge C18 (250 mm × 4,6 mm). A fase móvel foi composta por solução tampão pH 4,9 / acetonitrila (35:65, v/v) eluída no fluxo de 1,0 mL/min e detecção no ultravioleta em 289 nm. A separação cromatográfica foi obtida no tempo de 7,0 min, sendo linear na faixa de concentração de 5-100 μg/mL (r = 0,9999). Paralelamente, desenvolveu-se e validou-se método por espectrofotometria no ultravioleta em 289 nm utilizando metanol como diluente. Também foi desenvolvido e validado método por cromatografia eletrocinética micelar utilizando nimesulida como padrão interno. As análises foram realizadas em capilar de sílica fundida (comprimento efetivo de 40 cm e diâmetro de 50 μm), mantido a 30°C, utilizando solução eletrolítica composta de tampão borato 40 mM e SDS 50 mM, pH 9,2, com detecção no ultravioleta em 216 nm. A injeção foi realizada no modo hidrodinâmico a 50 mbar durante 7 s e voltagem constante de 28 kV foi aplicada durante as análises. A separação eletroforética foi obtida em 7,0 min, sendo linear na faixa de 25-150 μg/mL (r = 0,9995). Os procedimentos foram validados considerando-se os parâmetros especificidade, linearidade, precisão, exatidão, limite de detecção e quantificação e robustez, cujos resultados cumpriram os requisitos preconizados. Os métodos propostos foram aplicados na análise quantitativa de produtos farmacêuticos, demonstrando correlação significativa dos resultados (p > 0,05). Desenvolveu-se e validou-se método por espectrofotometria no UV utilizando tampão acetato pH 4,5 como diluente e detecção em 289 nm, o qual foi aplicado para avaliar a percentagem dissolvida dos comprimidos de dronedarona. O método de dissolução foi desenvolvido utilizando como meio 900 mL de tampão acetato pH 4,5 mantido a 37°C, aparato pá e rotação de 75 rpm.
39

Olmesartana medoxomila : validação de metodologia analítica, avaliação biofarmacêutica e análise polimórfica / Olmesartan medoxomil: validation of analytical methodology, biopharmaceutical evaluation, and polymorphic analysis

Bajerski, Lisiane January 2010 (has links)
O pró-fármaco olmesartana medoxomila (OLM) é um anti-hipertensivo representante da classe dos bloqueadores seletivos dos receptores da angiotensina II (BRA). No Brasil, encontra-se disponível sob a forma de comprimidos revestidos (Benicar®). Foi aprovado pelo FDA em 2002. Não existe monografia disponível para este fármaco em nenhum código oficial. Desse modo, este trabalho objetivou o desenvolvimento de métodos analíticos para quantificação da OLM na substância química de referência (SQR) e forma farmacêutica, estabelecer a cinética de dissolução in vitro para os comprimidos revestidos deste fármaco e por fim investigar a presença de diferentes estruturas polimórficas da SQR deste anti-hipertensivo. A determinação da faixa de fusão, a espectrofotometria na região do infravermelho (IV), assim como a espectroscopia de ressonância magnética nuclear (RMN) de 1H e 13C permitiram a identificação da SQR. Os métodos por espectrofotometria na região do ultravioleta (UV), cromatografia em camada delgada (CCD), cromatografia a líquido de alta eficiência (CLAE) e cromatografia capilar eletrocinética micelar (MECC) foram utilizados para análise qualitativa do fármaco no produto acabado. A determinação quantitativa foi realizada através do desenvolvimento e validação de método indicativo da estabilidade por CLAE e MECC, avaliando-se os parâmetros descritos pelas guias de validação como: especificidade, robustez, linearidade, limites de detecção e quantificação, precisão e exatidão. Determinou-se ainda, a intercambialidade dos mesmos, através de análise estatística por ANOVA (p = 0,05), e comprovou-se que ambos podem ser utilizados para análise qualitativa e quantitativa da OLM em matéria-prima e produto acabado. O teste de dissolução foi desenvolvido e validado de acordo com o guia proposto pelo USP Fórum, utilizando como meio de dissolução 900 ml de uma solução a 0,5% (p/V) de lauril sulfato de sódio pH 6,8, a 37 ± 0,5 °C, pás a 50 rpm e quantificação por CLAE e espectrofotometria na região do UV. A análise do teor de OLM dissolvida, realizada por ambos os métodos, não apresentou diferença estatística (p > 0,05). Os perfis de dissolução do Benicar®, medicamento referência, e do Olmetec®, outra formulação disponível no mercado, foram considerados semelhantes, após aplicação do método modelo-independente (f1 e f2) e eficiência de dissolução. Avaliou-se, também, a cinética de dissolução de ambas as formulações através da aplicação de métodos modelo-dependentes. Os perfis de dissolução do Benicar® e Ometec® foram descritos pelos modelos propostos por Hixson-Crowell e de ordem zero, respectivamente. Os valores calculados para t50% e t80%, obtidos através da aplicação da equação de ordem zero, foram semelhantes aos valores experimentais encontrados no perfil de dissolução de ambos os produtos. As técnicas de espectrofotometria por reflexão difusa no IV com transformada de Fourier (ATRFTIR), difração de raios-X de pó (XRPD), calorimetria exploratória diferencial (DSC), termogravimetria (TGA) e microscopia eletrônica de varredura (MEV) permitiram a identificação de uma forma amorfa e outra polimórfica da SQR da OLM, diferentes daquela descrita na literatura. Logo, de acordo com os resultados obtidos, todos os métodos propostos podem ser utilizados para no controle de qualidade da OLM em SQR e produto acabado. / The prodrug olmesartan medoxomil (OLM) is a selective angiotensin II receptor blocker (ARB). In Brazil, it is available as coated tablets (Benicar®). It was approved by FDA in 2002. There is no monograph available for this drug in any official code. According to this, the main purpose of this study was to develop a quality control analytical methodology for OLM in bulk material and dosage form, to establish in vitro dissolution kinetic for OLM coated tablets, and to investigate the crystalline behavior of OLM bulk material. The investigation of melting range and application of techniques such as infrared spectrophotometry (IR), as well as the 1H and 13C nuclear magnetic resonance (NMR) spectroscopy were used to identify OLM. Ultraviolet (UV) spectrophotometry, thin-layer chromatography (TLC), highperformance liquid chromatography (LC) and micellar electrokinetic chromatography (MEKC) were used for qualitative analysis of the drug in coated tablets. The quantitative determination was carried out through the development and validation of a stability-indicating LC and MEKC methods, evaluating the parameters described in the guidelines such as: specificity, robustness, linearity, detection and quantitation limits, precision, and accuracy. The results were compared statistically by ANOVA (p = 0.05), and no difference was found between them for both bulk material and coated tablets. A dissolution test was developed and validated according to the guideline proposed by the USP Forum, using 900 ml of dissolution medium containing 0.5% of sodium lauryl sulfate (w/V) pH 6.8, at 37 ± 0.5 °C, paddle at 50 rpm, and quantitation by LC and UV spectrophotometry. The resulting dissolution profiles did not show statistical difference (p > 0.05) between methods. The dissolution profiles of Benicar®, reference formulation, and Olmetec®, another commercial formulation available, were considered similar, using model independent (f1, f2, and dissolution efficiency) methods. The dissolution kinetic of both formulations, using model dependent approaches, revealed that Benicar® followed the Hixson-Crowell model, while Olmetec® the zero-order model. The calculated values of t50% and t80%, obtained from zero-order equation, were similar of experimental values found in the dissolution profile for both products. The attenuated total reflectance Fourier transformed infrared (ATR-FTIR) spectrophotometry, along with differential scanning calorimetry (DSC), thermogravimetry (TG), X-ray powder diffraction (XRPD), and scanning electron microscopy (SEM) allowed to identify one amorphous and other polymorphic forms of OLM. According to the obtained results, all proposed methods could be used in the quality control of OLM bulk material and coated tablets.

Page generated in 0.0485 seconds