• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 5
  • 1
  • 1
  • Tagged with
  • 41
  • 22
  • 9
  • 9
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Construção e aplicação de um Turbidímetro / Nefelômetro Microcontrolado Portátil / Construction and application of a portable microcontrolled turbidimeter nephelometer

Santos, Vagner Bezerra dos 30 July 2009 (has links)
Made available in DSpace on 2016-06-02T20:36:22Z (GMT). No. of bitstreams: 1 2551.pdf: 7371466 bytes, checksum: 71ef99e7141b5664de0e2594fbac263a (MD5) Previous issue date: 2009-07-30 / Financiadora de Estudos e Projetos / Development of a portable, simple and inexpensive equipment with adequate sensitivity for turbidimetric and/or nephelometric sequential analyses practically simultaneous is the aim of this study. In fact, in-situ and on-line analysis of chemical substances of interest (analytes) can be accomplished. This is requested mainly in situations in which the place is difficult to access or even in circumstances in which the physical- chemical characteristics of the samples should be unchanged. Thus, the equipment was applied in- situ sulfate determination in lake samples. Analytes of interest such as N-acetylcysteine, captopril and thiamine in pharmaceutical samples and potassium in isotonic beverages were also analyzed with the developed instrumentation. The PMTN (Portable Microcontrolled Turbidimeter Nephelometer) is made of LEDs (Light Emitting Diodes) as radiation sources, phototransistors as optical sensors and a PIC microcontroller (Peripherical Interface Controller) as processing unit for control and data acquisition. The PMTN was tested and calibrated properly according to the norms establish by ISO 7027 for equipment base on LEDs as radiation source. The PMTN was applied to determine the concentration of analytes and compared with the reference or validated methods for each analyte, as described in the literature. In general, results agreed at the 95% confidence level were obtained. The detection limits and quantification for the determination of the several analytes were agreed with in some better cases than those found in the literature. On average, the PMTN furnished two decades of linear range of concentration and a reproducibility (RSD) lower than 3.0 % with an average error of less than 5.0 % were also obtained. / A necessidade de um equipamento portátil, simples, de baixo custo e com boa sensibilidade para análises turbidimétricas e/ou nefelométricas de modo praticamente simultâneo motivou o desenvolvimento da presente dissertação de mestrado. Com esse equipamento, foi possível a realização de determinações de substâncias químicas de interesse (analitos) in-situ e em tempo real. Esse tipo de determinação é requerido principalmente em situações onde o deslocamento ao local é difícil, ou até mesmo, em circunstâncias nas quais as características físico-químicas das amostras devem ser rigorosamente inalteradas. Neste contexto, o equipamento foi aplicado na determinação de sulfato em águas de lago com análise em tempo real e no local de coleta. Analitos de interesse como Nacetilcisteína, captopril e tiamina em amostras farmacêuticas e potássio em bebidas também foram determinados com o emprego da instrumentação desenvolvida. O equipamento, intitulado PMTN (do inglês Portable Microcontrolled Turbidimeter Nephelometer), é composto principalmente por LEDs (do inglês Light Emitting Diodes), fototransistores como sensores ópticos e um microcontrolador PIC (Peripherical Interface Controller) como unidade de processamento, controle e aquisição de dados. O PMTN foi devidamente testado e calibrado conforme as normas exigidas pela ISO 7027 para equipamento à base de LEDs como fonte de radiação. Devidamente calibrado, o PMTN foi aplicado para determinações dos analitos supracitados e comparado com os métodos de referência ou métodos validados para cada analito descritos na literatura. Em todas as aplicações, os resultados obtidos empregando-se o equipamento foram concordantes a um nível de confiança de 95 %. Os limites de detecção e de quantificação para a determinação dos diversos analitos foram compatíveis e em alguns casos melhores que os encontrados na literatura. Em média duas décadas de faixa linear de concentração e uma reprodutibilidade (RSD) menor que 3,0 % com erros relativos em média menores que 5,0 % também foram obtidos.
12

Desenvolvimento de um fluorímetro microcontrolado para determinação de clorofila a em águas superficiais

Guerreiro, Thiago Brito 29 July 2010 (has links)
Made available in DSpace on 2016-06-02T20:36:26Z (GMT). No. of bitstreams: 1 3179.pdf: 1125649 bytes, checksum: 2420c47e3cef37ca39869c4481c09bd0 (MD5) Previous issue date: 2010-07-29 / Universidade Federal de Sao Carlos / In this work a portable fluorimeter was developed and used for determination of chlorophyll a in water samples. The instrument was constructed using the following components: a microcontroller (PIC18F4550), two LEDs as light source, a multichannel photodiode (TCS-230) as detector and a digital display. LEDs with maximum emission at 405 and 760 nm were used. The detector is equipped with three internal optical filters inside with maximum sensitivity at 480, 540 and 690 nm besides the possible use without the optical filter with high sensitivity in the visible spectral region with maximum sensitivity at 680 nm. The microcontroller works as central processing unit controlling all components of the instrument by a program previously recorded in its memory eliminating the need of a microcomputer. The fluorimeter was calibrated using standard solutions of fluorescein and rhodamine 6G in HCl 1.0 x 10-5 mol L-1 and performance was compared with a commercial spectrofluorimeter, and the results are in agreement at a confidence level of 95%. A linear response range for fluorescein was obtained between 0.5 and 100.0 x 10-6 mol L-1 and a correlation coefficient of 0.996 and for rhodamine 6G a linear response range between 0.2 and 10.0 x 10-6 mol L-1 was obtained and a correlation coefficient of 0.989. The fluorimeter was used for determination of chlorophyll a in water samples and blue algae culture medium. The results were compared with a spetrophotometric method and were in agreement at a confidence level of 95%. A linear range of between 2.5 and 1333.6 x 10-6 g L-1 for chlorophyll a was obtained with a correlation coefficient of 0.995. The concentration range attend the requirements of CONAMA resolution n° 357 that classifies the water quality covering the concentrations of 10.0, 30.0 and 60.0 x 10-6 g L-1 for different classes of water. The fluorimeter is inexpensive, easy to use shows, low power consumption allowing the feed with batteries, small size (10 cm x 20 cm x 15 cm) and with weight of 0.76 kg. The fluorimeter can be used to determine species with excitation at 405 and or 476 nm and emission across the visible range with excellent performance. / Neste trabalho foi desenvolvido um fluorímetro portátil para determinação de clorofila a em águas superficiais. O instrumento foi construído utilizando os seguintes componentes: um microcontrolador (PIC18F4550), dois LEDs como fonte de radiação, um fotodiodo multicanal (TCS-230) como detector e um mostrador digital. Foram utilizados LEDs com máximo de emissão em 405 e 476 nm. O detector utilizado é dotado de três filtros ópticos internos com máximos de transmissão em 480, 540 e 680 nm permitindo, ainda a sua utilização sem os filtros com elevada sensibilidade em toda a região do espectro visível(máximo em torno de 690 nm). O microcontrolador atua como unidade central de processamento sendo todos os componentes do instrumento controlados por ele a partir de um programa previamente gravado em sua memória, dispensando o uso de um microcomputador. O fluorímetro construído foi calibrado utilizando soluções de fluoresceína e rodamina 6G em solução de HCl 1,0 x 10-5 mol L-1 e o desempenho foi comparado com um espectrofluorímetro de bancada, sendo os resultados obtidos concordantes a nível de confiança de 95%. Foi obtida uma faixa de resposta linear para fluoresceína entre 0,5 e 100,0 x 10-6 mol L-1 e um coeficiente de correlação de 0,996 e para rodamina 6G uma faixa linear de resposta entre 0,2 e 10,0 x 10-6 mol L-1 e um coeficiente de correlação de 0,989. A instrumentação desenvolvida foi utilizada para a determinação de clorofila a em amostras de água superficiais e em amostras de meio de cultura de algas azuis e os resultados foram concordantes ao nível de significância de 95 % quando comparados com um método comparativo espectrofotométrico. Para a clorofila a obteve-se uma faixa de concentração entre 2,5 e 1333,6 x 10-6 g L-1 e um coeficiente de correlação linear de 0,995. O intervalo obtido atende à resolução CONAMA n° 357 que dispõe sobre a classificação da qualidade de corpos d água que estabelece as concentrações de 10,0, 30,0 e 60,0 x 10-6 g L-1 para os diferentes tipos de classes de águas. O fluorímetro construído é de baixo custo, de fácil utilização, de baixo consumo de corrente permitindo sua utilização com pilhas ou baterias e de reduzidas dimensões (10 cm x 20 cm x 15 cm) com massa total de 0,76 kg. O fluorímetro pode ser utilizado na determinação de espécies com excitação em 405 e/ou 476 nm e emissão em toda a faixa do visível com excelente desempenho.
13

Sistema microcontrolado para medição de forças na região plantar e nos membros superiores de pacientes

Sanches, Marcelo Augusto Assunção [UNESP] 27 April 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-04-27Bitstream added on 2014-06-13T20:08:24Z : No. of bitstreams: 1 sanches_maa_me_ilha.pdf: 1862589 bytes, checksum: e3625c1d280204f136503179cec091dd (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este trabalho descreve um sistema eletrônico implementado com o objetivo de monitorar os esforços exercidos pelos membros superiores e inferiores de pacientes. O sistema é constituído por transdutores, circuitos de condicionamento de sinais, circuito de comunicação e um software para a aquisição de dados, além da visualização em um microcomputador. São descritos dois tipos de transdutores, construídos com extensômetros metálicos, um para conexão em muletas e o outro projetado para ser inserido em palmilhas. Os fundamentos teóricos necessários para o projeto destes transdutores são apresentados, bem como os esquemas dos circuitos implementados. É descrita a metodologia utilizada para a determinação das características estáticas e dinâmicas dos transdutores. Estes apresentaram respostas lineares, excelente repetibilidade, e faixa dinâmica que atende às finalidades do projeto. Foi desenvolvido um software com interface gráfica contendo várias telas que possibilitam diferentes análises e armazenamento de informações. Utilizando o sistema, foram realizadas, com êxito, medições de forças exercidas pelos membros inferiores e superiores de pacientes normais e hemiplégicos. / This work describes the development of a computer-based system able for monitoring forces acting on patients’ upper and lower limbs. The system consists of insoles and crutches instrumented with load cells, signal conditioning circuits, data acquisition system, and a computer. The results of the static and dynamic measurements can be presented in the screen of a computer through graphs and tables, and stored in a data base, to follow-up the development of a patient treatment. The program was developed in Visual Basic, and the communication uses the USB port. All transducers presented linear response, small hysteresis, excellent repeatability and resolution. Static and dynamic measurements performed with the transducers are presented as well as the visualization of the forces exerted on the plantar area and upper limbs of healthy and hemiplegic patients.
14

Investigação de novas ferramentas estatísticas e utilização de microcontrolador no monitoramento da queima na retificação plana tangencial

Khenaifes, Maurício [UNESP] 26 June 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-06-26Bitstream added on 2014-06-13T20:32:13Z : No. of bitstreams: 1 khenaifes_m_me_bauru.pdf: 11653802 bytes, checksum: 00691f8a0498d00bcda7c19abcca703d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Auto Financiadora / Na indústria moderna, a precisão e o custo são fundamentais para a qualidade do produto e competitividade no mercado. Desenvolver sistemas mais velozes, dinâmicos e autoajustáveis aplicando técnicas de controle é um objetivo dos pesquisadores de todas as áreas da engenharia. A retificação de materiais é um sistema complexo que possui muitas variáveis relacionadas, principalmente por possuir múltiplas arestas de corte associado a altas velocidades e potências de retificação. Para aumentar o domínio sobre o processo, sinais de emissão acústica e de potência de acionamento do rebolo têm sido monitorados em várias pesquisas. Nesse trabalho foram realizadas experiências utilizando a retificação plana tangencial com o aço ABNT 1020 e rebolo de óxido de alumínio, onde foi determinado a ocorrência e o início da queima através da variação da profundidade de corte, tendo-se o cuidado de manter os outros parâmetros constantes, inclusive a superfície de corte do rebolo através da operação de dressagem. Os sinais de emissão acústica e de potência elétrica foram adquiridos durante uma passada do rebolo sobre a peça, numa taxa de 2.5 milhões de amostras por segundo, e pro cessados através de um ferramental matemático, onde foram propostos outros parâmetros, para a análise da ocorrência da queima. Observou-se também a detecção do início da queima, onde o parâmetro proposto VARPO obteve bons resultados. Paralelamente foi realizado um estudo sobre os microcontroladores, onde foram inseridos os cálculos de detecção da queima do processo de retificação num PIC18F452, mostrando a viabilidade de um monitoramento. / In modern industry, the accuracy and cost are extremely important to the quality of product and market competition. The development of faster dynamic and robust systems by applying control techniques is the goal of researchers of all engineering areas. The grinding process is a complex system which contains many related variables mainly because its multiple cutting edges associated with high speed and power. In order to improve the knowledge on the process, acoustic emission and power signals have been monitored in several research investigations. In this work, surface grinding tests with ABNT 1020 steel and aluminum oxide grinding wheel were carried out in which the burning occurrence as well as the onset of it were studied. This was done by varying the depth of cut and maintaining the other grinding parameters constant, including the grinding wheel surface through the dressing operation. Acoustic emission and electrical power signals were acquired during a single grinding pass of the grinding wheel over the work-piece at 2.5 million of samples per second rate. The signals were digitally processed through many statistic algorithms among which new parameters for burn detection have been proposed. Also, the onset of burning occurrence was observed and remarkably detected for the proposed parameter dubbed VARPO. In addition, a study on microcontrollers was performed, and the implementation of the algorithms previously mentioned were carried out into the microcontroller PIC18F452, showing the monitoring feasibility.
15

Prot?tipo de rastreador solar de um eixo baseado em microcontrolador

Ara?jo, Jonas Damasceno Batista de 09 December 2015 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2016-07-22T15:28:33Z No. of bitstreams: 1 JonasDamascenoBatistaDeAraujo_DISSERT.pdf: 3604743 bytes, checksum: 5ae42e6f32fd99f10a6d6092e639b58a (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2016-07-27T21:50:25Z (GMT) No. of bitstreams: 1 JonasDamascenoBatistaDeAraujo_DISSERT.pdf: 3604743 bytes, checksum: 5ae42e6f32fd99f10a6d6092e639b58a (MD5) / Made available in DSpace on 2016-07-27T21:50:25Z (GMT). No. of bitstreams: 1 JonasDamascenoBatistaDeAraujo_DISSERT.pdf: 3604743 bytes, checksum: 5ae42e6f32fd99f10a6d6092e639b58a (MD5) Previous issue date: 2015-12-09 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / O aumento da efici?ncia de sistemas foto-voltaicos tem sido alvo de diversos estudos nos ?ltimos anos. Uma das formas poss?veis de aumentar a pot?ncia extra?da por um painel foto-voltaico ? o rastreamento solar, realizando a sua movimenta??o de modo a seguir a trajet?ria do sol. Esta movimenta??o exige que o motor el?trico empregado possua torque suficiente e baixa velocidade, garantindo a precis?o do rastreamento. Com o uso de inversores tipo fonte de tens?o e de dispositivos que gerem a l?gica de chaveamento adequada ? poss?vel obter o torque e a velocidade necess?rios para o funcionamento do sistema. Este trabalho descreve a implementa??o de um sistema de controle de posi??o a ser aplicado no rastreador solar constru?do no Laborat?rio de Eletr?nica de Pot?ncia e Energias Renov?veis, situado na UFRN. A varia??o da velocidade do motor ? realizada atrav?s de um inversor tipo fonte de tens?o cujo comando PWM para acionamento das chaves ser? gerado por um dispositivo microcontrolador dedicado. O sensor utilizado para medi??o da inclina??o do painel ? um sensor de estado s?lido do tipo aceler?metro interfaceado ao microcontrolador. A posi??o solar ? tamb?m calculada pelo microcontrolador ? partir das coordenadas geogr?ficas do ponto de instala??o, e da data e hora locais obtidas a partir de um dispositivo RTC (Real-Time Clock). Um prot?tipo de rastreador solar polar de um eixo, movimentado por um motor CC, foi montado para atestar o funcionamento do sensor e verificar se o rastreamento ? realizado de forma eficiente. / The increase in the efficiency of photo-voltaic systems has been the object of various studies the past few years. One possible way to increase the power extracted by a photovoltaic panel is the solar tracking, performing its movement in order to follow the sun?s path. One way to activate the tracking system is using an electric induction motor, which should have sufficient torque and low speed, ensuring tracking accuracy. With the use of voltage source inverters and logic devices that generate the appropriate switching is possible to obtain the torque and speed required for the system to operate. This paper proposes the implementation of a angular position sensor and a driver to be applied in solar tracker built at a Power Electronics and Renewable Energies Laboratory, located in UFRN. The speed variation of the motor is performed via a voltage source inverter whose PWM command to actuate their keys will be implemented in an FPGA (Field Programmable Gate Array) device and a TM4C microcontroller. A platform test with an AC induction machine of 1.5 CV was assembled for the comparative testing. The angular position sensor of the panel is implemented in a ATMega328 microcontroller coupled to an accelerometer, commanded by an Arduino prototyping board. The solar position is also calculated by the microcontroller from the geographic coordinates of the site where it was placed, and the local time and date obtained from an RTC (Real-Time Clock) device. A prototype of a solar tracker polar axis moved by a DC motor was assembled to certify the operation of the sensor and to check the tracking efficiency.
16

Desenvolvimento de um leitor digital de absorbância microprocessado / SILVA, A. J. Development of a digital reader Absorbance microprocessor . Dissertation (Master) Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto - SP, 2011.

Aldriano José da Silva 04 March 2011 (has links)
O espectrofotômetro, aparelho muito utilizado para realizar leituras de absorbância e/ou transmitância de amostras laboratoriais, pode ser aplicado para a realização de leituras do dosímetro químico Fricke Xilenol Gel. Este aparelho, por possuir componentes eletrônicos avançados e ser importado, apresenta um custo elevado e acaba muitas vezes se tornando um dispositivo inviável para medidas mais simples e rotineiras. O presente estudo implementou-se um aparelho portátil e de baixo custo, para que medidas específicas de absorbância possam ser feitas em laboratórios de ensino de física e que possa ser aplicado como leitor de dosímetros géis, como o acima citado. Este monoespectrofotômetro é constituído por uma fonte LED (próximo a 590 nm), um fotodiodo para avaliação da intensidade da luz transmitida e um display de LCD. Tal leitor permite a comunicação com microcomputadores via porta USB, facilitando o trabalho do usuário para manipular os resultados das medidas. A principal finalidade é voltada para uso acadêmico, no entanto, devido ao seu baixo custo e simplicidade, poderá também ser direcionado para atender outros segmentos como ambulatorial, industrial, cosmético, biológico, agronômico, dentre outros. / The spectrophotometer, a device often used to perform absorbance readings and or transmittance of laboratory samples, can be applied to perform readings in the chemical dosimeter Fricke Xylenol Gel. This device, once it has advanced electronics components and is imported, has an elevated cost and often ends up becoming an impractical device for most simple measurements and routine. This study implemented a device portable and inexpensive, so that specific measurements absorbance can be made in teaching laboratories of physics and that can be applied as a gel dosimeter reader, like the above. This monospectrophotometer consists of a LED source of visible light (near 590 nm), a photodiode to assess the intensity of transmitted light and an LCD display. This reader allows communication with computers via USB port, making it easier for users to manipulate the results of the measurements. The main purpose is directed for academic use, however, due to its low cost and simplicity, may also be applied to attend other segments such as outpatient, industrial, cosmetic, biological, agronomic, among others.
17

Sistema digital de instrumentação sem fio de uma mola Helicoidal TI-NI usando tecnologia zigbee, usb e linux

de Santana Bezerra Ramos, Jadeilson 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T17:35:16Z (GMT). No. of bitstreams: 2 arquivo2009_1.pdf: 3503480 bytes, checksum: 85d90aa1952ca122f373c0f061692038 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / O padrão zigbee foi utilizado na instrumentação de molas helicoidais de Ti-Ni utilizando, assim, a porta USB para comunicação de dados sem fio com o laptop e a mola utilizando a plataforma operacional Linux. Um estudo do comportamento da tensão elétrica da mola Ti-Ni sob a variação da corrente elétrica e distensão mecânica foi feito. Foi observado que para condições normais de temperatura e ambiente, o sistema apresentou variação linear na faixa analisada. E que uma análise estatística para uma faixa de operação de corrente e comprimentos constantes, a mola apresentou condições suficientes para a instrumentação. Foram desenvolvidos programas para que as tecnologias zigbee, microcontrolador, PIC16F877A e USB pudessem se comunicar entre si. A implementação do algoritmo sugerido mostrou-se, ao longo dos testes, um desempenho positivo. Uma análise do erro que o sistema de instrumentação sem fio poderia introduzir no monitoramento foi feita. Com isso, constatou-se que o erro absoluto do mesmo não apresentou nenhuma influência no monitoramento da distensão mecânica da mola. Os resultados mostraram-se favoráveis ao objetivo da dissertação e foi verificado que o monitoramento sem fio de distensão mecânica da mola Ti-Ni apresentou confiabilidade considerável
18

PWM discreto para controle de velocidade com tabelas pré-programadas reduzidas / PWM control for discrete speed with preprogarmmed tables reduced

Alice Reis de Souza 17 December 2011 (has links)
Devido à preocupação com a preservação do meio ambiente, estudos em várias áreas surgiram, inclusive no que diz respeito à qualidade do ar. Dentre as pesquisas encontram-se estudos para o desenvolvimento do veículo elétrico, uma fonte de energia limpa. Para controlar a velocidade, o freio e a reversão do movimento de um motor de indução trifásico utilizado neste tipo de veículo, foram desenvolvidos vários tipos de circuitos geradores de PWM com microcontroladores da família 8051 e PIC. Observando o avanço da tecnologia na fabricação de microcontroladores, o objetivo desta pesquisa foi o desenvolvimento de um circuito com um microcontrolador compatível com a família 8051 para implementação de um controlador de velocidade discreto para obter, além de um desempenho melhor que o alcançado com o circuito já desenvolvido com o microcontrolador 80C31, também minimizar tabelas pré-programadas utilizadas em estudos anteriores a fim de obter um circuito reduzido mantendo baixo custo. O microcontrolador escolhido foi o AT89S4051, que possui apenas 20 pinos, opera com frequências até 24MHz, por programação permite redução do tempo necessário para executar instruções enquanto que o 80C31 possui 40 pinos, opera com frequências até 16MHz e trabalha com tempo fixo para executar instruções. Foram desenvolvidos programas que permitiram a utilização de tabelas pré-programadas reduzidas e o acelerador foi implementado sem o uso de conversor A/D. A simulação permite verificar a reduzida geração de harmônicas da técnica, permitindo a utilização em eletrodomésticos, em que a alimentação é originada da rede pública. / Because of concern about preserving the environment, studies have emerged in several areas, including with regard to air quality. Among the studies are studies for the development of electric vehicle, a clean energy source. To control speed, brake and reverse the motion of a three phase induction motor used in this type of vehicle have been developed various types of circuits that generate PWM with 8051 family microcontrollers and PIC. Noting the advancement of technology in the manufacture of microcontrollers, the objective of this research was to develop a circuit with a microcontroller compatible with the 8051 to implement a speed controller for discrete, and a better performance than that achieved with the circuit already developed with the 80C31 microcontroller, also minimize pre-programmed tables used in previous studies to obtain a small circuit while maintaining low cost. The microcontroller chosen was the AT89S4051, which has only 20 pins, operates at frequencies up to 24MHz, programming allows reducing the time required to execute instructions while the 80C31 has 40 pins, operates at frequencies up to 16MHz and works with a fixed time to execute instructions. Programs were developed that allowed the use of tables and pre-programmed low throttle was implemented without the use of A/D converter the simulation allows to verify the reduced harmonic generation technique, allowing for use in electronics, where power is derived from the public network.
19

Queima microcontrolada de baixas e inconstantes vazões de biogás para estações de tratamento de esgoto

Osmar da Rocha Simões 13 December 2012 (has links)
Este trabalho apresenta um sistema Queimador Registrador de Baixas Vazões de Biogás que permite a queima de biogás em miniestações de tratamento de esgoto, em que o aproveitamento energético não é viável devido à baixa e inconstante vazão de biogás. Este sistema vai ao encontro das necessidades mundiais de redução na emissão dos gases do efeito estufa, em especial o gás metano, presente no biogás produzido por meio da digestão anaeróbica do esgoto sanitário, que é aproximadamente vinte e uma vezes mais impactante à atmosfera que o gás carbônico. O princípio se baseia no armazenamento do biogás em um gasômetro volumétrico, tipo telescópio, que depois de cheio libera o biogás que é queimado automaticamente, podendo o volume queimado ser quantificado para posterior obtenção de créditos de carbono. O sistema de controle é de baixo custo e pode ser absorvido por instalações de pequeno porte. Para que o módulo de controle tenha capacidade de monitorar e quantificar o volume de biogás queimado, foram utilizados: um sensor para detecção do nível do gasômetro cheio, um sensor para detecção do nível do gasômetro vazio, uma válvula para controle da entrada de gás e um centelhador semelhante ao utilizado em um fogão de cozinha para a queima do biogás. Também foi utilizado um contador que permite o sistema quantificar o número de vezes que o gasômetro foi esvaziado e contabilizar o volume de biogás queimado. / This work presents a system Burner Recorder Low Flows Biogas which allows the burning of biogas in sewage treatment small stations, in which the energy use is not feasible due to the low and unstable flow of biogas. This system meets the needs of global reduction in emissions of greenhouse gases, particularly methane, present in the biogas produced by the anaerobic digestion of sewage, which is approximately twenty-one times more damaging to the atmosphere than carbon dioxide. The principle is based on biogas storage in a volumetric gasometer, a kind of telescope, which after full releases biogas which is automatically burned, making it possible to be quantified to subsequently carbon credits attainment. It is a low cost system and can be absorbed by small installations. In order to enable the control module to monitor and quantify the volume of biogas burned, it was necessary to use a sensor for level detection of the full gasometer, a sensor for level detection the level of the empty gasometer, a valve to control the entry of gas and a spark-gap similar to that used in a kitchen stove for biogas burning. It was also utilized a counter which allows the system to quantify the number of times the gasometer was emptied and to measure the volume of biogas burning.
20

Sistema de alerta basado en tecnología Arduino para el apoyo en la atención inmediata de accidentes o emergencias médicas de los residentes con enfermedades crónicas de un condominio de la ciudad de Chiclayo

Romero Flores, Jose Luis January 2019 (has links)
El Condominio Médico Daniel Alcides Carrión (Av Grau 1300), es un grupo habitacional conformado por 224 personas (47 casas), ubicado en la ciudad de Chiclayo, en donde la mayoría de sus residentes son profesionales de la salud y cumplen con horarios de trabajo divididos por turnos diurnos y nocturnos. En dicho condominio existen personas con enfermedades crónicas y que necesitan del cuidado de un familiar o personas especializadas en cuidados médicos, pero, a pesar que son muy esmerados en los cuidados y estrictos en la medicación de las personas que sufren enfermedades crónicas, siempre existen accidentes o situaciones que no son controladas a tiempo debido a: Falta de una alerta temprana que dé aviso sobre un accidente ocurrido con estas personas, esto ha conllevado a que dichas personas no sean atendidas a tiempo y por ende se complique su situación y tengan que ser internadas en un hospital por periodos largos hasta que se estabilice su situación. Por tal motivo en este trabajo de investigación se vio la manera en cómo la tecnología de alerta inalámbrica de Arduino pueda ayudar a los residentes del Condominio Médico Daniel Alcides Carrión, en la implementación de un sistema de alerta temprana, para atender los accidentes o situaciones médicas de los residentes con enfermedades crónicas. Con la aplicación de esta tecnología se espera apoyar en la atención a tiempo de los accidentes o emergencias médicas de los residentes con enfermedades crónicas del Condominio Médico Daniel Alcides Carrión de la ciudad de Chiclayo, implementando una central de alerta para la atención inmediata de accidentes o emergencias médicas de los residentes y estableciendo las interfaces de comunicación entre los sensores de alerta Arduino y la interfaz usuaria para una fácil y rápida atención.

Page generated in 0.0913 seconds