• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 141
  • 4
  • 1
  • Tagged with
  • 147
  • 128
  • 29
  • 28
  • 26
  • 22
  • 20
  • 20
  • 19
  • 18
  • 17
  • 17
  • 17
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Influência de cinco géis clareadores e de um gel remineralizante sobre a ultra-estrutura e  microdureza do esmalte e da dentina de dentes humanos / Influence of five bleaching gels and a remineralizing gel on the enamel and dentin ultrastructure and microhardness

Helena Burlamaqui Pinheiro 18 May 2009 (has links)
Objetivo: Avaliar, através de análise ultra-estrutural e teste de microdureza, a influência de um gel remineralizante e de cinco géis clareadores sobre o esmalte e a dentina de dentes humanos. Material e Método: 10 coroas de molares tiveram o terço oclusal e cervical removidos (5 coroas serviram para análise ultra-estrutural e 5 para ensaio de microdureza). Cada remanescente coronário foi seccionado em 7 fatias (análise ultra-estrutural) e 6 fatias (ensaio de dureza Knoop). Para análise ultra-estrutural, as fatias foram divididas entre 7 grupos (n=5), sendo um deles o grupo controle. Os outros 6 fragmentos foram divididos em 6 grupos experimentais de acordo com os materiais a serem aplicados em esmalte e dentina, sendo: 1 gel remineralizador, Relief ACP (Rel ACP); 2 géis clareadores convencionais, Opalescence PF (Opal) e Whiteness Perfect (WP); 2 géis contendo PO4 e Ca, Nite White ACP (NW ACP) e Day White ACP (DW ACP) e um gel clareador contendo Ca, White Class Ca (WC Ca). Para o ensaio de microdureza, os 6 fragmentos foram divididos entre os 6 grupos experimentais acima, sendo que todos os fragmentos tiveram o seu valor inicial de dureza em esmalte (Ei) e dentina (Di) aferidos e, em seguida, os géis foram aplicados de acordo com instruções dos fabricantes. Os produtos foram aplicados por 14 dias, durante 30 minutos (grupo Rel ACP), 4h diárias (gupos NW ACP, Opal e WP) e por 1h diária (grupos DW ACP e WC Ca). Após cada sessão de tratamento remineralizador ou clareador, os espécimes foram armazenados em água destilada (37ºC). Após 24h de finalizados os tratamentos, os espécimes foram preparados para análise em microscópio eletrônico de varredura por emissão de campo e também foram determinados os valores finais de microdureza para esmalte (Ef) e dentina (Df). Resultados: Os clareadores convencionais, assim como o clareador que continha apenas cálcio, causaram desmineralização no esmalte e na dentina e redução dos valores de dureza nesses dois tecidos (Opal: Ei=308,9; Ef=278,5; Di= 51,7; DF=44,0 / WP: Ei=316,8; Ef=291,2; Di=50,3; DF=34,8 / WC Ca: Ei=315,7; Ef=289,7; Di=52,1; DF=44,8) (p<0,05). Já os clareadores que continham cálcio e fosfato (NW ACP e DW ACP) e o gel remineralizante (Rel ACP) não causaram desmineralização nem redução nos valores de dureza do esmalte e da dentina (NW ACP: Ei=313,8; Ef=315,7; Di=51,7; DF=48,2 / DW ACP: Ei=320,7; Ef=316,2; Di=53,7; DF=52,6 / Rel ACP: Ei=310,1; Ef=314,8; Di=48,9; DF=46,5). Conclusão: O gel remineralizante (Rel ACP) e os agentes clareadores que contêm Ca e PO4 (NW ACP e DW ACP) não provocaram alterações na estrutura e nem na microdureza do esmalte e da dentina. Os géis clareadores convencionais (Opal e WP), assim como o gel clareador contendo apenas cálcio, WC Ca, promoveram alterações no esmalte e na dentina e redução dos valores de microdureza nos dois tecidos. / Objective: The aim of this in vitro study was to evaluate, through ultrastructural analysis and microhardness test, the influence of a remineralizing gel and five bleaching gels on enamel and dentin of human teeth. Material and Method: 10 third molars crowns had occlusal and cervical portions removed (5 crowns used for ultrastructural analysis and 5 for microhardness test). Each remaining coronary structure were cut in 7 slices (ultrastructural analysis) and 6 slices (Knoop hardness test). For ultrastructural analysis, the slices were divided into 6 groups (n=5), one being the control group. The other 6 slices were distributed into 6 experimental groups, one remineralizing gel, Relief ACP (Rel ACP); 2 conventional bleaching gels, Opalescence PF (Opal) and Whiteness Perfect (WP); 2 gels with Ca and PO4, Nite White ACP (NW ACP) and Day White ACP (DW ACP) and a bleaching gel with calcium, White Class Ca (WC Ca). After each session of remineralizing or bleaching treatment, the specimens were stored in distilled water (37º C). After 24 hours of completed treatments, the specimens were examined by field emission in-lens scanning electron microscopy (FEISEM) and then, final values were determined for enamel (Ef) and dentin (Df) microhardness. Results: The conventional bleaching gels and the bleaching gel with calcium, caused demineralization in enamel and dentin and reduce the hardness values of these two tissues (Opal: Ei=308,9; Ef=278,5; Di= 51,7; DF=44,0 / WP: Ei=316,8; Ef=291,2; Di=50,3; DF=34,8 / WC Ca: Ei=315,7; Ef=289,7; Di=52,1; DF=44,8) (p <0.05). Already, the bleaching with calcium and phosphate (NW ACP and DW ACP) and the remineralizing gel (Rel ACP) did not cause demineralization or reduction in the enamel and dentin hardness values (NW ACP: Ei=313,8; Ef=315,7; Di=51,7; DF=48,2 / DW ACP: Ei=320,7; Ef=316,2; Di=53,7; DF=52,6 / Rel ACP: Ei=310,1; Ef=314,8; Di=48,9; DF=46,5). Conclusion: The remineralizing gel (Rel ACP) and the bleaching agents with Ca and PO4 (DW ACP and NW ACP) did not cause changes in the ultrastructure nor the enamel and dentin microhardness. The conventional bleaching gels (Opal and WP) and the bleaching gel with calcium, WC Ca, promoted changes in enamel and dentin and reduction of the microhardness values in the two tissues.
72

Estudo \'in situ\' do efeito remineralizador da saliva e do flúor após profilaxia com jato de bicarbonato de sódio sobre o esmalte hígido / In situ study of the saliva and fluoride recovery effect on enamel after sodium bicarbonate jet application

Gladis Benjamina Grazziotin 08 May 2007 (has links)
O objetivo deste estudo foi avaliar in situ o efeito da saliva, associada ou não ao flúor, sobre a estrutura dentária do esmalte que recebeu profilaxia prévia com jato de bicarbonato de sódio. Foram utilizados 40 blocos de esmalte de dente bovino de 4x4 mm, nos quais foi aplicado o jato de bicarbonato de sódio por 10s, simulando a realização de uma profilaxia profissional. Após essa etapa, os blocos foram divididos em dois grupos (GI e GII) e montados em dispositivos intra-bucais, os quais foram utilizados por 10 voluntários, durante dois períodos experimentais cruzados e cegos de quatro horas. Os blocos do GI foram expostos diretamente à saliva in situ, enquanto os do GII, foram expostos à saliva associada ao flúor sob forma de bochecho com solução de NaF a 0,2%, durante o minuto inicial. As possíveis alterações ocorridas na superfície do esmalte após as etapas do experimento foram avaliadas através de testes de microdureza superficial (Knoop-25g/5s) e de desgaste. Os dados de microdureza superficial foram analisados pela Análise de Variância a dois Critérios (ANOVA) e teste de Tukey (p<0,05) e os dados de desgaste pelo teste T pareado, para a diferença entre perfil inicial e final (p<0,05). Não foi encontrada diferença estatisticamente significante entre GI e GII, para as variáveis dureza e desgaste. A média de desgaste após profilaxia não apresentou diferença da média após a etapa in situ. No entanto, a média de microdureza no início, após a profilaxia e após a etapa in situ foi respectivamente: GI (340±16,6a; 329±35,7b; 354±37,8a) e GII (338±15,6a; 312 ±46,3b; 340±21,8a). Com base nos resultados encontrados pôde-se concluir que a saliva apresentou efeito semelhante a saliva associada ao bochecho fluoretado e após 4 horas de remineralização in situ não houve recuperação em altura de parte da estrutura dentária perdida devido à aplicação do jato de bicarbonato de sódio sobre o esmalte hígido. / The aim of this in situ study was to evaluate the effect of the saliva, associated or not to fluoride, on the superficial enamel structure in which a sodium bicarbonate jet was applied. Forty bovine enamel specimens (4x4 mm) were subjected to sodium bicarbonate jet for 10 seconds to simulate a prophylaxis procedure. The specimens were then divided the in two groups (GI and GII) and were mounted in a intra-oral device which were used by 10 volunteers for two cross-over, blind experimental periods of 4 hours. The specimens of GI were directly exposed to saliva in situ, while those of GII were exposed to saliva associated to fluoride by mouthrinsing 0,2%NaF solution on the first minute of the experiment. The changes on the enamel surface were analyzed by superficial microhardness test (Knoop, 25g/5s) and perfilometry (wear). Two-way ANOVA and Tukey test (p<0,05) were used for microhardness data. The wear was analyzed by T pare test for the initial and final profile difference (p<0,05). There were no statistically difference between GI and GII, in respect to microhardness and wear. The mean enamel wear after sodium bicarbonate jet application was not significantly different from the enamel mean wear after the in situ phase. However the microhardness mean values at baseline, after sodium bicarbonate jet application and after in situ phase were respectively: GI (340±16.6a; 329±35.7b; 354±37.8a) e GII (338±15.6a; 312 ±46.3b; 340±21.8a). In according to the obtained results it was concluded that saliva presented the same effect on enamel recovery when compared to saliva associated to fluoride. After 4 hours of in situ remineralization, it was not observed the height recovery of the enamel, lost by wear due to the use of a sodium bicarbonate jet application.
73

Progressão da lesão de cárie no esmalte dental após aplicação de compostos fluoretados e irradiação com laser de CO2 / Progression of caries-like lesions following CO2 laser irradiation or fluoride sources in human and bovine enamel.

Aline Evangelista de Souza Gabriel 18 December 2009 (has links)
A presente tese foi dividida em 2 estudos cujos objetivos específicos foram: 1) Comparar in vitro o efeito da irradiação do laser de CO2 a compostos fluoretados na inibição da progressão de lesões de cárie, e testar se o padrão de resposta é similar ao esmalte humano e bovino. 2) Avaliar in situ a progressão da lesão de cárie no esmalte bovino e verificar as quantidades de flúor no biofilme e no esmalte após tratamento com verniz fluoretado associado ou não ao laser de CO2. No primeiro estudo, 96 fragmentos de esmalte (48 humanos e 48 bovinos) foram distribuídos aleatoriamente em 4 grupos (n=12): CO2 - laser de CO2 (10,6 &micro;m), VF - verniz fluoretado a 5%, FFA - flúor fosfato acidulado a 1,23% e ST - sem tratamento. Os espécimes foram submetidos a 14 dias de desafio cariogênico (ciclagem de pH). A microdureza (KHN) foi medida a 30 &micro;m da superfície. Vinte fragmentos adicionais de cada substrato receberam os mesmos tratamentos (n=5) e foram analisados em microscopia eletrônica de varredura (MEV).No estudo in situ (cruzado e realizado em 2 fases de 14 dias cada), 14 voluntários (n=14) utilizaram um dispositivo palatino contendo blocos de esmalte bovino que foram previamente submetidos a um dos 4 tratamentos: VF + CO2 - verniz Fluoretado a 5% + laser de CO2, VF- verniz fluoretado a 5%, VP - verniz placebo sem flúor, VP + CO2 - verniz placebo + laser de CO2. Biofilme dental foi acumulado sobre os blocos e 6 vezes ao dia os voluntários gotejavam solução de sacarose, simulando um desafio cariogênico. Após cada fase, os blocos foram removidos para avaliação da desmineralização do esmalte (teste de microdureza) e concentração de fluoreto no biofilme e esmalte após o desafio cariogênico. A microdureza foi avaliada pela Análise de Variância e teste de Tukey e as dosagens de flúor no biofilme e esmalte pelo teste não paramétrico de Friedman (&alpha; = 5%). No estudo in vitro, verificou-se que o laser de CO2 promoveu a menor perda mineral, seguido do tratamento com VF e FFA, o desempenho inferior na inibição da progressão de cárie foi obtido com o grupo controle (ST) (p < 0,05), em resumo: CO2 > VF > FFA > ST. O dente bovino apresentou maiores valores de microdureza que o humano, embora o comportamento dos substratos tenha sido o mesmo para todos os tratamentos. A MEV demonstrou presença de fino precipitado granuloso para o grupo VF e fusão e fissuras para o grupo tratado com CO2. No estudo in situ, independentemente da aplicação dos vernizes fluoretado ou placebo, a microdureza do esmalte foi estatisticamente superior (p < 0,05) quando esse substrato foi irradiado com laser de CO2. Quando a aplicação dos vernizes não foi seguida pela irradiação com laser de CO2, não houve diferença estatisticamente significante (p > 0,05) na microdureza do esmalte bovino em função do uso do produto fluoretado e placebo. Ao analisar o biofilme dental, observou-se que o grupo tratado com VF apresentou maior quantidade de flúor, estatisticamente diferente dos demais grupos (p < 0,05), que foram estatisticamente semelhantes entre si (p > 0,05). No esmalte, a maior quantidade de flúor foi encontrada no grupo VF + CO2 (p < 0,05), que não diferiu estatisticamente do VF (p > 0,05). Conclui-se que: 1) O laser de CO2 controlou a progressão de cárie in vitro mais eficazmente que compostos fluoretados de alta concentração e, que o esmalte bovino pode ser um substituto ao esmalte humano em estudos desta natureza; 2) O laser de CO2 promoveu maior inibição da progressão de cárie, em modelo in situ, independentemente da aplicação dos vernizes fluoretado ou placebo. O uso do verniz fluoretado resultou em maior quantidade de flúor no biofilme dental, enquanto que, a associação verniz fluoretado e laser de CO2 proporcionou maior incorporação de flúor no esmalte. / This thesis was divided into 2 studies whose specific objectives were: 1) To compare the ability of CO2 laser and fluoride sources to inhibit caries-like lesions in human enamel and to test whether a similar pattern of response would hold for bovine enamel. 2) Evaluate in situ the progression of caries lesions in bovine enamel and to verify the amount of fluoride present in biofilm and enamel after treatment with fluoride varnish combined with CO2 laser. In the first study, 96 enamel slabs (48 from bovine and 48 from human teeth) were randomly distributed into 4 groups (n=12): CO2 - CO2 laser, FV - 5% fluoride varnish, APF - 1.23% acidulated phosphate fluoride gel, or WT - without treatment (control). Specimens were subjected to a 14-day in vitro cariogenic challenge. Microhardness (SMH) was measured at 30 &micro;m from the surface. Additional 20 slabs of each substrate (n=5) received the same treatment described above and were analyzed by scanning electron microscopy (SEM). In the in situ study (crossover and performed in 2 phases of 14 days each), 14 (n = 14) wore palatal appliance with bovine enamel blocks that were previously submitted to one of the 4 treatments: FV + CO2 - 5% fluoride varnish + CO2 laser, FV - fluoride varnish, PV - placebo varnish without fluoride, PV + CO2 - placebo varnish + CO2 laser. Dental biofilm was allowed to accumulate on the blocks and 6 times a day a drop of sacarose solution was dispensed into emamel blocks by volunteers, simulating a cariogenic challenge. After each phase, the blocks were removed to evaluate enamel demineralization (microhardness test) and concentration of fluoride in biofilm and enamel after cariogenic challenge. Microhardness was evaluated by ANOVA and Tukey test, and the amount of fluoride present in biofilm and enamel were analysed by non-parametric Friedman test (&alpha; = 5%). CO2 laser promoted the least mineral loss. Treatment with FV resulted in the second highest values, which was followed by APF. Untreated specimens performed the worst (p < 0,05), in summary: CO2 > FV > APF > WT. Bovine teeth presents higher values of microhardness than human, although the performance of both substrates were the same. SEM showed a granulate precipitate on FV group and fusion ang fissures on lased-specimens. In in situ study, regardless of the application of fluoride or placebo varnish, the microhardness of enamel was statistically superior (p < 0.05) when the substrate was irradiated with CO2 laser. When the varnishes application were not followed by the irradiation of CO2 laser, no significant statistical diference were observed in the bovine enamel (p > 0.05). When analyzing the dental biofilme, it was observed that the group treated with VF presented larger amount of fluoride, statistically different from the other groups (p < 0.05), which were statistically similar among themselves (p > 0.05). In the enamel, the largest amount of fluoride was found in the FV + CO2 group (p < 0.05), which was not statistically different from FV (p > 0.05). It was concluded that: 1) CO2 laser may control caries progression more efficiently than fluoride sources and bovine teeth may be a suitable substitute for human teeth in studies of this nature; 2) CO2 laser promoted larger inhibition of the caries progression, in in situ model, independently of the application of fluoride or placebo varnish. The use of fluoride varnish fluoretado resulted in larger amount of fluoride in dental biofilme, while, the association of fluoride varnish and CO2 laser provided larger fluoride uptake in the enamel.
74

Endurecimiento por Precipitación de Aleación de Cu- 2% wt. Co

Bórquez de la Rosa, Rodrigo Ignacio January 2009 (has links)
El cobre es un elemento metálico que, se caracteriza por ser uno de los mejores conductores eléctricos y térmicos. Sin embargo, sus propiedades mecánicas son más bien bajas comparado con otros metales. El objetivo general del presente trabajo de título fue estudiar el proceso de precipitación en aleación de Cu - 2% Co (% peso) y su efecto sobre el endurecimiento de la matriz. Para realizar este trabajo se utilizó una metodología que involucró la obtención de muestras y probetas, aplicación de tratamientos térmicos, análisis energético y cinético mediante el uso de Calorimetría Diferencial de Barrido (DSC) y aplicación de los modelos matemáticos Kissinger Modificado y Mehl-Johnson-Avrami (MJA), análisis de segregación de soluto a las dislocaciones y análisis de microdureza Vickers. Las curvas calorimétricas de la aleación templada muestra, la presencia de dos efectos exotérmicos traslapados, en todas las velocidades de calentamiento lineal utilizadas, que pueden ser asociadas a la formación de precipitados en la matriz de cobre, ricos en Cobalto-α. Se puede afirmar que el sistema está gobernado por variables cinéticas más que termodinámicas. La energía de activación es 164,7 y 195,6 [kJ/mol] para las etapas 1 y 2, respectivamente. El valor de la etapa 2 es bastante cercano al teórico, que es de 200,6 [kJ/mol], mientras que el de la etapa 1 es menor, lo que se puede atribuir a la presencia de vacancias introducidas por el temple. Los resultados cinéticos indican que, en el caso de la etapa 1, se está en presencia de un fenómeno de precipitación por nucleación y crecimiento, en cuanto a la etapa 2, se tiene un proceso de crecimiento a partir de núcleos pre-existentes de tamaño no despreciable. En cuanto a la deformación en frío, se llegó a la conclusión que al aumentar esta, se tiende a inhibir la etapa 2 de precipitación, debido a segregación de soluto en las dislocaciones en la etapa 1 donde cuando comienza la precipitación. Por lo tanto, la aleación endurece por dos procesos, formación de precipitados y segregación de estos átomos de cobalto a las dislocaciones, entorpeciendo su movimiento. La microdureza Vickers para el material templado es superior a medida que aumenta la temperatura de envejecimiento, llegado a los 84, 1[HV], en cuanto a el material deformado en frío, se concluye que mientras aumenta la deformación, mayor es la dureza, llegándose a 141,5 [HV] para el caso de 50% de deformación en su espesor. Cabe mencionar que para ambos casos, material templado y sin deformar, la medida de dureza fue 65,8 [HV]. Se concluye que el material endurece por formación de precipitados y además que algunos de estos son segregados a las dislocaciones, lo que también aumenta las propiedades mecánicas.
75

Avaliação da rugosidade e microdureza de superfície de compósitos restauradores submetidos a dois tipos de polimentos / Evaluation of the surface roughness and microhardness of composites submitted to two polishing techniques

Patrícia Schunck Alferes Marques 26 June 2009 (has links)
Objetivo: Comparar compósitos diretos e indiretos em relação à rugosidade de superfície e microdureza Knoop e a efetividade de sistemas de polimento multipasso e passo único sobre a superfície destes materiais. Método: Foram confeccionados 34 corpos-de-prova para cada material, sendo dois compósitos restauradores para uso direto e dois para uso indireto. A análise inicial da rugosidade de superfície foi realizada em vinte corpos-de-prova de cada material restaurador, com o rugosímetro Surftest SV-3000, filtro de 0,25mm (cut-off) e comprimento de leitura de 1,25mm. A microdureza inicial foi mensurada em dez corpos-de-prova de cada grupo, com uso de um microdurômetro MVD 401, sob carga de cinquenta gramas por 12 segundos. Quatro corpos-de-prova de cada compósito foram submetidos à análise topográfica por microscopia de força atômica. Ao final das análises iniciais de rugosidade de superfície e microdureza Knoop, os corpos-de-prova foram igualmente divididos em dois subgrupos conforme o sistema de polimento a ser empregado: sistema de passo único (Pontas Pogo) e sistema multi-passo (Discos Sof-lex). Após o polimento, foi realizada nova análise da rugosidade de superfície, da microdureza Knoop e microscopia de força atômica. As médias obtidas nos ensaios foram submetidas à Análise de Variância (ANOVA) e ao teste t de student, nível de significância de 5%. Resultados: Os valores médios da rugosidade (Ra - &#956;m) após polimento com Sof-Lex variaram de 0,13&#956;m (Sinfony) a 0,29&#956;m (Charisma). Após polimento com Pogo, variaram de 0,13&#956;m (Charisma) a 0,20&#956;m (Sinfony), sem diferença estatística entre os compósitos testados. Para o teste do microdureza Knoop, os valores médios (Kg/mm2) após polimento com Sof-Lex variaram entre 18,86 (Sinfony) e 68,67 (Filtek Z350), sendo que o compósito Filtek Z350 foi associado a valores estatisticamente superiores quando comparado aos demais compósitos. Não foram observadas diferenças estatísticas entre os compósitos Charisma e Signum, e o compósito Sinfony apresentou médias de dureza estatisticamente inferiores. Após o polimento com Pogo, as médias variaram de 18,95 (Sinfony) a 64,34 (Filtek Z350), sendo que diferenças estatísticas foram observadas entre todos os compósitos avaliados, na seguinte ordem decrescente: Filtek Z350, Charisma, Signum e Sinfony. Conclusões: O polimento com Sof-Lex foi mais efetivo na redução da rugosidade para os compósitos indiretos, sendo que não foram observadas diferenças entre os compósitos após polimento com Pogo. A efetividade do sistema de polimento na redução da rugosidade de superfície está mais relacionada com características individuais dos compósitos que com a classificação. O polimento realizado tanto com Sof-Lex como com Pogo causou em todos os compósitos (com exceção do Signum) uma redução significativa na microdureza de superfície. / Objective: The aim of the present study was to compare direct and indirect composites in relation to the superficial topography and Knoop microhardness and to evaluate the effectiveness of polishing techniques (multi-step and single-step) on the surface of these materials. Method: Four commercially available resin composites were tested, two direct and two indirect composites. For each material, 34 samples were confectioned. The initial analysis of roughness was performed in twenty samples of each restorative material, using a Surftest SV-3000 profilometer, with parameters of 0.25&#956;m (cut-off) and 1.25mm (length of reading). The initial microhardness was measured in ten samples of each group, using a microhardness unit MVD 401, under load of fifty grams per 12 seconds. Four samples of each resin composite were confectioned to Atomic Force microscopy (AFM). After initial analysis, samples were randomly divided in two sub-groups in agreement to the polishing technique used: single-step polishing (Pogo - Dentsply) or multi-step polishing (Sof-lex - 3M ESPE). After polishing, final measurements of roughness, microhardness and AFM were performed. Results were analyzed by ANOVA and students t test (&#945; = 0.05). Results: The mean values of roughness (Ra - &#956;m) after polishing with Sof-Lex ranged from 0.13&#956;m (Sinfony) to 0.29&#956;m (Charisma), and indirect composites presented statistically lower mean values when compared to direct composites. No statistical difference was observed among composites after polishing using Pogo. The mean values of microhardness after polishing using Sof-Lex varied between 18,86 (Sinfony) and 68,67 (Filtek Z350). Filtek Z350 was associated with higher mean values when compared to the other composites. No difference between Charisma and Signum was observed, and the composite Sinfony presented the lowest mean value of hardness. After polishing using Pogo, statistically different microhardness values were observed among all evaluated composites, in the following decreasing order: Filtek Z350, Charisma, Signum and Sinfony. Conclusions: Polishing with Sof-Lex was more effective in the reduction of roughness for the indirect composites. However, composites presented similar performance after polishing with Pogo. The effectiveness of the polishing system in the reduction on superficial roughness is more related to individual characteristics of the composite than with its classification. Polishing using Sof-Lex and Pogo caused to all composites (exception to Signum) a significant reduction of the mean microhardness.
76

Avaliação da microdureza, rugosidade superficial e morfologia de dois compósitos submetidos ao clareamento dental e escovação simulada

Paulo Roberto Marão de Andrade Carvalho 17 July 2008 (has links)
O objetivo deste trabalho foi avaliar os efeitos da escovação com o uso de dentifrícios e tratamento clareador na superfície do compósito microhíbrido e nanoparticulado. Foram confeccionados corpos-de-prova com dimensões padronizadas (6 x 3 mm) das resinas Filtek Z-250 (microhíbrida, 3M/ESPE) e Filtek Z-350 (nanoparticulada, 3M/ESPE) (n= 120). Cada resina foi subdivida em seis tratamentos superficiais: controle (sem tratamento); tratamento clareador (Whiteness 16% - FGM); escovação com dentifrício convencional (Colgate Total 12); escovação com dentifrício clareador (Colgate Total 12 Whitening Gel - Palmolive); clareamento e escovação com dentifrício convencional e clareamento e escovação com dentifrício clareador. O tratamento clareador foi realizado durante quatro horas diárias por 15 dias. Após cada ciclo clareador, as amostras eram armazenadas em saliva artificial em estufa a 37 C até a próxima aplicação do gel clareador. Os grupos não clareados foram mantidos em saliva durante o experimento. Após o clareamento, foi realizada a escovação simulada (trinta mil ciclos) nos grupos préestabelecidos. Antes e após o clareamento e escovação, foi determinada a microdureza e rugosidade superficial dos compósitos. Duas amostras de cada grupo foram preparadas para observação em microscopia eletrônica de varredura (MEV). A rugosidade e microdureza obtida antes e após os tratamentos foram estatisticamente analisadas (ANOVA e Tukey/Kramer, p< 0,05). Inicialmente todos os grupos apresentaram valores de dureza e rugosidade semelhantes, entretanto, houve aumento da rugosidade da resina submetida à escovação e submetida ao clareamento associado à escovação com os dentifrícios A e B (p< 0,05). Não houve, todavia, alteração na microdureza superficial da resina Z350 após os tratamentos, enquanto o grupo 1 apresentou significante redução na dureza após o tratamento. Pode-se concluir que a escovação e o clareamento, em especial a associação destes, aumentam a rugosidade dos compósitos, mas não alteram a dureza da resina microhíbrida ou da nanoparticulada. / The aim of the present study was to evaluate the effects of simulated toothbrushing with dentifrices and bleaching treatment on the surface of microhybrid and nanofilled composites. Standardized samples (6x3 mm) Filtek Z-250 (microhybrid, 3M/ESPE) and Filtek Z-350 ( nanofilled, 3M/ESPE) were made (n= 120). Each composite was subdivided into six surface treatments: control (no treatment); bleaching treatment (Whiteness 16% - FGM); brushing with conventional dentifrice (Colgate Total 12); brushing with whitening dentifrice (Colgate Total 12 Whitening Gel Palmolive); bleaching and brushing with conventional dentifrice and bleaching and brushing with whitening dentifrice. Bleaching treatment was performed for four hours and 15 days. After each bleaching cycle, samples were stored in artificial saliva at 37 C until the next bleaching application. The non-bleached group remained stored in artificial saliva throughout all experiment. After bleaching, simulated toothbrush (thirty thousand cycles) were performed in the pre-established groups. Before and after bleaching and brushing, surface microhardness and roughness was performed on composite surface. Two samples of each group were prepared to scanning electron microscopy observation (SEM). Surface roughness and microhardness before and after treatments were statistically analyzed (ANOVA and Tukey/Kramer, p< 0,05). At baseline, all groups presented similar hardness and roughness values, however, there was a surface roughness increase on composite surface submitted to brushing and to bleaching associated to brushing with the dentifrices A and B (p< 0,05). On the other hand, there were not differences of the hardness of the Z350 composite after treatments, while 1 presented significant reduction of surface hardness after treatment. It could be concluded that brushing and bleaching, specially the association of both, increase composite surface roughness but do not alter surface microhardness of microhybrid and nanofilled composites.
77

Clareamento dental interno: efeito de diferentes sistemas na microdureza e micromorfologia superficial da dentina bovina / Effect of different bleaching systems on the microhardness and ultrastructure of bovine dentin

Guerisoli, Laise Daniela Carrasco 07 January 2008 (has links)
Este estudo teve como objetivos: 01.Avaliar ex vivo o efeito de diferentes sistemas clareadores na microdureza dentinária em dentes bovinos submetidos ao clareamento dental interno. 02.Avaliar ex vivo o efeito de diferentes sistemas clareadores na morfologia superficial da dentina bovina. Fragmentos de 4 x 4mm, contendo esmalte e dentina, foram obtidos de coroas de incisivos bovinos extraídos. Os espécimes foram submetidos ao clareamento dental interno com peróxido de hidrogênio a 35% e peróxido de carbamida a 37% utilizando sistemas convencionais (Opalescence Endo® and Whiteness Super Endo®) e fotoativados (Opalescence Xtra® and Whiteness HP Maxx®). Os controles foram tratados com perborato de sódio misturado com peróxido de hidrogênio a 10% ou nenhum tratamento foi realizado. A microdureza dentinária foi mensurada antes e após os tratamentos clareadores, e os valores de dureza Knoop (KHN) foram submetidos à análise estatística (two-way ANOVA, Tukey\'s port-test). Os espécimes foram observados e fotografados sob microscópio eletrônico de varredura e avaliados com relação às alterações morfológicas da superfície da dentina. Houve uma redução significante na microdureza dentinária para todos os grupos testados quando comparados aos grupos controles. Opalescence Xtra® (-11.36 ± 8.14 KHN), Opalescence Endo® (-13.71 ± 8.02 KHN), Whiteness HP Maxx® (-15.18 ± 9.58 KHN) e Whiteness Super Endo® (-16.97 ± 6.55 KHN) foram semelhantes estatisticamente. O grupo do perborato de sódio misturado com peróxido de hidrogênio 10% (2.10 ± 8.58 KHN) e o grupo sem tratamento clareador (-2.71 ± 2.40 KHN) também foram estatisticamente semelhantes entre si. Ocorreu uma grande variação no padrão de alterações da morfologia superficial da dentina com os sistemas clareadores utilizados. Todos os produtos testados apresentaram redução significativa da microdureza dentinária, exceto o grupo de perborato de sódio misturado com peróxido de hidrogênio a 10%. Ambos, pH e oxidação do peróxido de hidrogênio apresentam o papel de alterar a estrutura da dentina durante o clareamento interno. A utilização de produtos alcalinos com um tempo reduzido de aplicação (técnicas fotoativadas) pode diminuir as alterações morfológicas na dentina. / The aim of this study was: 01. To evaluate in vitro the effect of different in-office bleaching systems on the surface morphology of bovine dentin. 02. To evaluate ex vivo the effect of different bleaching systems on the microhardness of bovine dentine. Tooth fragments measuring 4 x 4mm, containing enamel and dentin, were obtained from the crowns of extracted bovine incisors. Samples were submitted to simulated intracoronal bleaching techniques with 35% hydrogen peroxide and 37% carbamide peroxide using conventional (Opalescence Endo® and Whiteness Super Endo®) and light activated systems (Opalescence Xtra® and Whiteness HP Maxx®). Controls were treated either with sodium perborate mixed with 10% hydrogen peroxide or no bleaching agent. Dentine microhardness values were measured before and after bleaching procedures, recorded as KHN (Knoop Hardness Number), and the differences between them analyzed (two-way ANOVA, Tukey\'s port-test). The samples were observed under SEM and the recorded images were evaluated for topographic alterations. Significant reductions of dentine microhardness were observed for all treatments when compared to the control groups. Opalescence Xtra® (-11.36 ± 8.14 KHN), Opalescence Endo® (-13.71 ± 8.02 KHN), Whiteness HP Maxx® (-15.18 ± 9.58 KHN) and Whiteness Super Endo® (- 16.97 ± 6.55 KHN) presented similar differences. The walking bleach technique (2.10 ± 8.58 KHN) and the untreated groups (-2.71 ± 2.40 KHN) were statistically alike.The ultrastructural alterations of dentin observed in this study varied greatly between groups, according to the products used. Apparently, higher pH products associated to in-office techniques yielded to better maintenance of dentin ultrastructure. The in-office products tested in the present study caused a significant reduction in dentine microhardness. The walking bleach technique did not affect dentine microhardness. Both low pH and hydrogen peroxide oxidation play a role in altering the ultrastructure of dentin during internal dental bleaching. The use of alkaline products with reduced time of application (in-office techniques) may decrease such morphological alterations.
78

Influência dos níveis de energia do laser Er:YAG na capacidade de ablação, microdureza e morfologia da dentina superficial e profunda / Influence of Er:YAG laser energy levels on ablation rate, microhardness and morphology of superficial and deep dentin

Chinelatti, Michelle Alexandra 18 March 2008 (has links)
O objetivo do presente estudo foi avaliar in vitro a influência dos níveis de energia do laser de Er:YAG para preparo cavitário na capacidade de ablação, microdureza e morfologia da dentina superficial e profunda. Foram selecionados 72 terceiros molares humanos hígidos, que tiveram as raízes removidas e as coroas seccionadas no sentido vestibulo-lingual, obtendo-se 144 fragmentos. Os fragmentos foram alocados aleatoriamente em 2 grupos: dentina superficial (as faces oclusais foram lixadas até 1 mm abaixo da junção amelodentinaria - JAD) e dentina profunda (2 mm abaixo da JAD). Posteriormente, cada grupo foi subdividido em 6 subgrupos (n=12) de acordo com as energias do laser de Er:YAG utilizadas (160, 200, 260, 300 ou 360 mJ, ou controle- sem irradiação). Para avaliar a capacidade de ablação, a massa (mg) de cada fragmento foi obtida antes e depois da irradiação. Para a realização do teste de microdureza Knoop, após a irradiação as cavidades foram incluídas em resina acrílica e seccionadas longitudinalmente. As marcações (10 g; 20 s) foram localizadas a 20, 40, 60, 80, 100 e 200 &micro;m abaixo da parede de fundo do preparo ou da margem superior dos espécimes do grupo controle. A análise morfológica foi realizada em MEV. Os valores de perda de massa e microdureza foram analisados individualmente pelos testes de ANOVA e Fisher (&alpha;=5%). Os resultados revelaram um aumento gradativo e significante na perda de massa quando se aumentou a energia do laser utilizada, independente do tipo de dentina irradiada, sendo que a energia de 360 mJ apresentou maiores valores e foi estatisticamente diferente das demais energias estudadas. Em relação a profundidade da dentina não observouse diferença significante entre elas. A análise morfológica evidenciou que a ablação foi mais seletiva na dentina profunda em que ocorreu mais intensamente a ablação da dentina intertubular, apresentando a protrusão dos túbulos dentinários, contudo, a energia de 360 mJ o aspecto morfológico da dentina profunda foi semelhante a superficial. Podendo assim concluir-se que o aumento da energia do laser proporcionou maior perda de massa, independente da profundidade da dentina, contudo, morfologicamente pôde-se observar que a dentina profunda promoveu uma ablação seletiva, com menor remoção da dentina peritubular. Em relação à microdureza, as médias da dentina superficial foram significantemente superiores às da dentina profunda. As energias de 160 e 360 mJ foram diferentes entre si e das demais. Houve diferença entre todos os pontos medidos. Não foram observadas alterações morfológicas marcantes. Concluiu-se que a capacidade de ablação não depende da profundidade dentinária; a microdureza diminuiu com o aumento da energia, porém aumentou em relação às profundidades. A energia de 160 mJ promoveu um aumento nos valores de microdureza da dentina superficial na região mais próxima do preparo; a microdureza da dentina profunda não foi alterada quando foram utilizadas as energias de 160 e 200 mJ, enquanto os níveis de energia superiores promoveram uma diminuição na microdureza das dentinas superficial e profunda. / This study evaluated the ablation rate and the subsurface microhardness of superficial and deep dentin irradiated with different Er:YAG laser energy levels, and observed the micromorphological aspects of the lased substrates by means of Scanning Electron Microscopy (SEM). Seventy-two molar crowns were bisected, providing 144 specimens, which were randomly assigned into two groups (superficial or deep dentin) and later into six subgroups (160, 200, 260, 300, or 360mJ, or control- not irradiated). Initial masses of the specimens were obtained before irradiation. After laser irradiation, final masses were obtained and cavities were longitudinally bisected in half, being one hemi-section destined to SEM analysis and the other to the Knoop microhardness test. Microhardness measurements were performed at six points (20, 40, 60, 80, 100, and 200 &micro;m) under the middle of the cavity floor. Data were submitted to ANOVA and Fisher\'s LSD Multiple-Comparison Tests (&alpha;=0.05). There was no difference between ablation rate of superficial and deep dentin; a significant and gradual increase in the mass-loss values was reached when energies were raised, regardless the dentin depth; the energy level of 360 mJ showed the highest ablation rate and was statistically different to the other energies. SEM images showed that deep dentin was more selectively ablated, especially intertubular dentin, promoting tubule protrusion; at 360 mJ, the micromorphological aspect was similar for both dentin depths. Superficial dentin presented higher microhardness than deep dentin; 160 mJ resulted in the highest microhardness values and 360 mJ the lowest ones; 200 mJ was lower than 160 mJ and the control, but it was higher than 260 and 300 mJ, which presented similar means. Values at all points were different, exhibiting increasing microhardness throughout; superficial dentin microhardness was the highest at 20 &micro;m with 160 mJ, while the other energies demonstrated lower values than the control at all points; on deep dentin, 160 and 200 mJ were similar to the control, and other energies promoted significantly lower values. It may be concluded that the ablation rate did not depend on the depth of the dentin; an energy level lower than 360 mJ is recommended to ablate either superficial or deep dentin effectively without causing tissue damage. The lowest energy level increased superficial dentin microhardness at the closest extension under the cavity preparation; deep dentin subsurface microhardness was not altered by 160 and 200 mJ, while higher energy levels reduced subsurface microhardness of both superficial and deep dentin.
79

Estudo de parâmetros para ensaios de microdureza em amálgama de prata, resina composta, dentina e esmalte bovinos / Study of the parameters for microhardness test on dentin and enamel bovines, composite resin and amalgam

Soprano, Valéria 12 February 2008 (has links)
A dureza é uma propriedade bastante utilizada para comparar tanto os materiais restauradores como os tecidos biológicos. É definida pela resistência do material à deformação plástica e mensurada pela relação da força aplicada e a área de endentação. Para esse estudo foram utilizados dois materiais: amálgama e resina composta e dois tecidos dentais: dentina e esmalte bovinos. No total foram confeccionados 20 espécimes, divididos em 4 grupos: A (Amálgama), R (Resina Composta), D (Dentina) e E (Esmalte) de acordo com cada superfície. Para os grupos A e R foram confeccionadas cavidades que foram restauradas com os respectivos materiais, no grupo E teve a superfície apenas planificada e o grupo D teve desgaste até a exposição de dentina. Para os testes foram utilizados os endentadores Vickers e Knoop; as cargas de 25, 50 e 100gf em cinco tempos de endentação 5, 15, 30, 45, e 60s. Os valores dos testes foram submetidos à análise estatística pelo teste Kruskall-Wallis e Student-Newman-Keuls (p<0,05). Os resultados permitiram concluir que para o amálgama deve se utilizar no mínimo uma carga de 50gf em um tempo mínimo de 30s tanto para a Vickers como para a Knoop. Na resina composta uma carga de 50gf e tempo de 45s para a Knoop e na dureza Vickers não apresentou diferenças. Na dentina a carga ideal é de pelo menos 50gf em qualquer dos tempos na dureza Vickers e Knoop. E o esmalte uma carga de 100gf para qualquer tempo na dureza Knoop. / The hardness is a mechanical property utilized to compare restorative materials such as biological tissue and can be defined as the resistance of material for a permanent impression and a number related to the applied force and the surface area. As each material has its own mechanical characteristic, for this study utilized two materials: amalgam and composite resin and two dental tissues: bovine dentin and enamel. In total were 20 specimes, divided among 4 groups: A, R, D, E equivalent for each superficial. The groups A and R received cavities preparation that were restored into with the respective materials, the group D had the superficial wore until exposure of the dentin and the group E was so planning. For the microhardness testing were utilized Vickers and Knoop indenter; loads of 25, 50 and 100gf in 5 time of application 5, 15, 30, 45 e 60 seconds. The values were submitted for statistical analysis by Kruskall-Wallis and Student-Newman-Keus tests (p<0.05). Due to the results, it is concluded that the amalgam presented a minimum load adequated of 50gf and a time of application of 30 seconds as the Vickers as Knoop. In the composite resin the minimum load was 50gf and time was 45s for Knoop, the Vickers didnt have statistical diference. In dentin the minimum load was 50gf for all studies times for two tests. And the enamel presented the minimum load adequated was 100gf for all the times in the Knoop microhardness, the Vickers test didnt have statistical diference.
80

AVALIAÇÃO DAS PROPRIEDADES MECÂNICAS E ADESIVAS DE CIMENTOS RESINOSOS UTILIZADOS NA CIMENTAÇÃO DE PINOS INTRARRADICULARES / Evaluation of the mechanical and adhesive properties of resin cements used in fiber post luting

Mora, Camilo Andrés Pulido 07 March 2017 (has links)
Made available in DSpace on 2017-07-24T19:22:04Z (GMT). No. of bitstreams: 1 Camilo Andres Pulido Mora.pdf: 15669266 bytes, checksum: ffecbe6f814025ea53601a49fb579e21 (MD5) Previous issue date: 2017-03-07 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aims of the study were: 1) to evaluate the bond strength (μTBS) and light transmission (LT) of individualized posts with different composite resin translucency,as well as the Vickers microhardness (VHN) of a self-adhesive resin cement. 2) to compare the shrinkage strain (SS), shrinkage rate (SR) and VHN of a conventionalcement and a self-adhesive one in the apical and cervical thirds of the root canal. 3) to compare the μTBS, VHN and nanoinfiltration (NI) immediately and after 3 years of a conventional resin cement and a self-adhesive one used in fiberglass post cementation. For the experiment 1, 70 lower premolars (n = 10) were selected and divided into 5 groups according to the resin translucency used for the post individualization: ideal adaptation (Positive control), high translucency composite resin (HT), Medium translucency composite resin (MT), high opacity composite resin (RAO) and pooradaptation (Negative Control); and cemented with dual resin cement RelyX U200 (3M / ESPE). One week later the BS, VHN and LT were evaluated.For experiment 2, 56 lower premolars were selected and endodontically treated. The teeth were randomly divided into 2 groups (n = 28) according to the resin cement used: RelyX ARC Group (3M / ESPE) and U200 Group: RelyX U200 (3M /ESPE). After that, 28 specimens (n = 14 per group) were sliced and submitted to VHN, BS and NI tests; And the other 28 specimens were sliced and stored in distilled water at 37 ° C for testing after 3 years. For experiment 3, 34 lower premolar teeth were selected and endodontically treated; Were then randomly divided into two groups (n = 14) according to the resin cement used: RelyX ARC Group (3M / ESPE) and U200 Group: RelyX U200 (3M / ESPE). Before the insertion of the resin cement in the root canal, two fiber optic sensors with Bragg gratings were placed in the post to measure cement deformation in the coronary and apical regions of the root canal. Data from each group (n = 10) were kinetically analyzed for polymerization Shrinkage strain (PS). The Shrinkage rate (SR) was calculated by numerical differentiation of the shrinkage data as a function of time. The experiments were analyzed by ANOVA and Tukey's test (a= 0.05). Experiment 1 showed a significant influence of resin translucency on resin cement properties. High translucency, promoted high μTBS and VHN. Experiment 2 showed that ARC had higher values of μTBS and VHN in the cervical third, but U200 presented the highest values after 3 years. In experiment 3 there was no difference in PS between the cements analyzed, but the ARC presented higher SR in both thirds. For the VHN, no significant difference in the cervical third was found, but U200 presented higher values in the apical third. / Os objetivos do estudo foram: 1) avaliar a resistência de união (RU) e transmissão de luz (TL) de pinos individualizados com diferente translucidez de resina composta, assim como a microdureza Vickers (MDV) de um cimento resinoso autoadesivo. 2) comparar a contração, taxa de contração e microdureza de um cimento convencional e um autoadesivo nos terços apical e cervical do canal radicular. 3) comparar a RU, MDV e nanoinfiltração (NI) imediata e após 3 anos de um cimento dual convencional e um cimento dual autoadesivo utilizados na cimentação de pinos de fibra de vidro. Para o experimento 1 foram selecionados 70 pré-molares inferiores (n=10) e divididos em 5 grupos segundo o grau de translucidez de resina utilizada para a individualização do pino: adaptação ideal (Controle positivo), resina de alta translucidez (HT), resina de média translucidez (MT), resina composta de alta opacidade (HO) e adaptação inadequada (Controle negativo); e cimentados com cimento resinoso dual RelyX U200 (3M/ESPE). Uma semana depois foi avaliada a RU, MDV e TL dos mesmos. Para o experimento 2, foram selecionados 56 dentes pré-molares inferiores e tratados endodonticamente. Os dentes foram divididos aleatoriamente em 2 grupos (n=28) segundo o cimento resinoso utilizado: Grupo ARC: RelyX™ ARC (3M/ESPE) e Grupo U200: RelyX U200 (3M/ESPE). Depois disso, 28 corpos-de-prova (n=14 por grupo) foram armazenados em água destilada por 48 h e depois cortados em fatias e submetidos a teste de MDV, RU e NI; e os outros 28 corpos-de-prova foram cortados em fatias e armazenados em água destilada a 37°C a fim de serem testados após de 3 anos. Para o experimento 3 foram selecionados 34 dentes pré-molares inferiores e tratados ndodonticamente;depois foram aleatoriamente divididos em 2 grupos (n=17) segundo o cimento resinoso utilizado: Grupo ARC: RelyX ARC (3M/ESPE) e Grupo U200: RelyX U200 (3M/ESPE). Antes da inserção do cimento resinoso no canal radicular foram posicionados no pino dois sensores de fibra óptica com redes de Bragg para a mensuração das deformações do cimento na região coronária e apical do canal radicular. Os dados de cada grupo (n=10) foram analisados cineticamente e para analisar a contração de polimerização (CPO). A taxa de contração (TP) foi calculada por diferenciação numérica dos dados de contração em função do tempo. Os experimentos foram analisados por ANOVA e teste de Tukey (a=0,05). O experimento 1 mostrou que há uma influência significativa da translucidez da resina nas propriedades do cimento. Quanto maior a translucidez, maior a RU e MDV. O experimento 2 mostrou que o ARC teve maiores valores de RU e MDV no terço cervical, mas foi o U200 quem apresentou maiores valores de RU e MDV após 3 9 anos. No experimento 3 não houve diferença na CPO entre os cimentos analisados, mas o ARC apresentou maior TP em ambos os terços. Para a MDV, não houve diferença significativa no terço cervical, mas o U200 apresentou maiores valores no terço apical.

Page generated in 0.0342 seconds