• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 1
  • Tagged with
  • 8
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comparación de microfiltración entre el cemento resinoso de espigos de fibra estándar y espigos de fibra anatomizados

Espinoza Surichaqui, Ana Maria January 2015 (has links)
La microfiltración en la interfase diente restauración, como consecuencia de la pobre adaptación marginal, es una causa significativa de caries secundarias, patologías infecciosas periapicales, fracturas y descementación de la restauración. El objetivo de este estudio fue comparar la microfiltración entre espigos de fibra estándar y espigos de fibra anatomizados teniendo como interfase un cemento resinoso. El estudio se realizó en 30 premolares humanos recientemente extraídos, se les realizó endodoncia siguiendo el protocolo de la Técnica Corono Apical. En 15 dientes se colocó el espigo de vidrio anatomizado con resina; y en 15 dientes se colocó el espigo de vidrio estándar; en ambos grupos se usó un cemento resinoso. Al finalizar esta etapa, se selló la superficie radicular. Luego la muestra fue sumergida en azul de metileno al 2% por 72 horas a temperatura ambiente, luego se colocó en una estufa a 37o por 24 horas después fueron almacenados por 24 horas en un recipiente seco para luego ser seccionados en sentido vestíbulo lingual. Se analizaron las muestras en un microscopio estereoscópico 8x. Se obtuvo como resultado que la microfiltración promedio para el grupo de espigos de fibra estándar fue de 4000.1 micras mientras que para el grupo de espigos de fibra anatomizados fue de 2567.8 micras. Al aplicar la Prueba T Student se determinó que existen diferencias estadísticas entre ambos grupos. Se concluyó que ninguna de las formas de espigos estudiados fue capaz de evitar por completo la microfiltración marginal en la interfase diente-poste. La microfiltración para los espigos de fibra estándar fue mayor que los espigos de fibra anatomizados, con una diferencia estadísticamente significativa. Palabras claves: Microfiltración, espigos anatomizados, cementación. / --- The microfiltration in the tooth restoration interface is a significant cause of secondary caries, periapical infectious diseases, fractures and debonding of the restoration. The aim of this study was to compare standard posts microfiltration between relined fiber posts having as a resin cement interface. The study was conducted on 30 human premolars recently extracted, was performed following the protocol of endodontic Technical Corono Apical. In 15 teeth relined fiber posts were placed; and 15 teeth post standard glass was placed; in both groups resin cement was used. At the end of this stage, the root surface is sealed. Then the sample was immersed in methylene blue 2% for 72 hours at room temperature, then placed in an oven at 37o for 24 hours after they were stored for 24 hours in a dry container before were sectioned transversally.. Samples were analyzed on a stereomicroscope 8x. The average microfiltration group standard post was 4000.1 microns while for the group relined fiber posts was 2567.8 microns. When applying the Student T test it was determined that there are statistical differences between groups. None of the forms of posts studied was able to completely prevent microleakage at the interface tooth-post. Microfiltration post standard fibers were greater than relined fiber posts, with a statistically significant difference. Keywords: Microleakage, relined fiber posts, cement.
2

Eficacia de un sistema autograbante usado como sellante de fosas y fisuras en piezas dentarias in vitro

Soto Recuay, Gabriela Del Pilar January 2015 (has links)
Los sellantes de fosas y fisuras se han utilizado con éxito en la odontología preventiva como barrera mecánica, evitando la propagación de lesiones cariosas. La colocación del sellante también puede incrementar el riesgo de caries dental cuando hay microfiltración, debido a un deficiente sellado, que muchas veces es consecuencia de la contaminación salival debido a que los pacientes no colaboran durante el tratamiento, en estos casos, ha surgido una nueva y revolucionaria categoría de resinas que contiene agentes autograbadores y adhesivos; que reduce el número de pasos operatorios y de esa manera evitar la microfiltración. El objetivo de este estudio fue demostrar la eficacia de una resina autograbante usada como sellante en fosas y fisuras, a través de la microfiltración. Se utilizaron 40 piezas dentarias entre premolares y molares permanentes sanas, extraídas por motivos ortodóncicos, fueron divididas en dos grupos: Grupo 1: sellante autograbante, Grupo 2: grabado con ácido y sellante convencional. Los dos grupos fueron termociclados a 500 ciclos, teñidos con azul de metileno al 2% durante 24 horas, recortados y finalmente observados al microscopio. Los datos fueron analizados con la prueba de Chi Cuadrado. Los resultados mostraron que ambos sistemas presentaron el mismo porcentaje de microfiltración, siendo el Grupo 2, el que presentó mayor porcentaje de microfiltración en la interfase sellante – diente (Grado 2) que el Grupo 1, mientras que el Grupo 1 presentó mayor porcentaje de microfiltración penetrando a nivel del fondo de la fisura (Grado 3) que el Grupo 2, sin embargo estas diferencias no fueron estadísticamente significativas (p<0.05). Se concluye que ninguno de los sistemas eliminó totalmente la microfiltración, el sistema autograbante presento mayor microfiltración penetrando en fosas y fisuras, deduciéndose que esto puede deberse a la viscosidad de la resina. Sin embargo ambos presentaron un buen sellado en el 42.5% de las muestras, siendo el sistema autograbante una buena alternativa para el uso de sellante de fosas y fisuras.
3

Membrane fouling characterization by confocal scanning laser microscopy

Zator, Maria Malgorzata 01 April 2009 (has links)
En sectores tan diversos como la industria alimentaria, la biotecnología y el tratamiento de aguas residuales, la filtración tangencial con membranas se viene utilizando de forma creciente en la separación, purificación y clarificación de distintas corrientes de proceso que contienen gran variedad de compuestos orgánicos. La limitación principal para el empleo industrial de las técnicas de separación por membranas es el ensuciamiento de éstas. El ensuciamiento se atribuye, de forma general, a la reducción en el diámetro de los poros, a su bloqueo y/o a la formación de un depósito en la superficie de la membrana. El avance en el desarrollo de técnicas para la caracterización, el control y la prevención del ensuciamiento de las membranas ha estado limitado por la falta de técnicas adecuadas y no invasivas para la medición del ensuciamiento. El objetivo principal del presente proyecto es desarrollar estrategias apropiadas para aplicar microscopía láser confocal de barrido (CSLM) al estudio del ensuciamiento de membranas de filtración, centrándose en el ensuciamiento causado por macromoléculas biológicas. En la tesis se han llevado a cabo experimentos de microfiltración (MF) de soluciones modelo puras y de mezclas de proteínas, polisacáridos y polifenoles. Las imágenes captadas mediante CSLM de las membranas al final de diferentes experimentos de filtración, han servido para obtener información cualitativa, sobre localización de las distintas moléculas, y cuantitativa, sobre la presencia individual de cada compuesto en el interior y la superficie de la membrana. Se han realizado también intentos de aplicación de visualización en línea mediante CSLM del proceso de microfiltración. / In fields such as the food and dairy industries, biotechnology, and the treatment of industrial effluents, pressure-driven membrane processes such as microfiltration are increasingly being used for the separation, purification and clarification of protein-containing solutions. A major limitation to the widespread use of membrane filtration, however, is fouling. Fouling is usually attributed to pore constriction, pore blocking or the deposition of cells and cell debris on the membrane surface and can lead to a reduction in the filtrate flux of more than an order of magnitude. Progress in developing a means for characterizing, controlling and preventing membrane fouling has been impeded by lack of suitable non-invasive fouling-measurement techniques. The main aim of this study is to develop suitable strategies for applying Confocal Scanning Laser Microscopy (CSLM) to characterise membrane fouling caused by biological macromolecules. Microfiltration experiments of single, binary and ternary model solutions of proteins, polysaccharides and polyphenols were carried out and CSLM images of the membranes at the end of the different filtration runs were obtained, in order to obtain quantitative and qualitative information about fouling patterns. Some trials of on-line monitoring of cross-flow microfiltration processes were also carried out.
4

Estudios comparativos in vitro de la microfiltración de restauraciones de resina compuesta realizadas con un sistema adhesivo convencional y otras realizadas con un sistema adhesivo con nanorelleno.

Beñaldo Fuentes, Clinton Rodrigo January 2005 (has links)
No description available.
5

Análisis comparativo in vitro del grado de microfiltración marginal de restauraciones de resina compuesta realizadas usando seis adhesivos de diferentes marcas comerciales, con y sin evaporar sus solventes.

Rich Ehrlich, Miguel January 2005 (has links)
No description available.
6

Comparación de la microfiltración del Ketac™ Molar e Ionofil Molar® con centrix y espátula TRA

Basurto Sampedrano, Katherine Elizabeth, Barragán Salazar, Nathaly Carolina January 2016 (has links)
Introducción: El tratamiento restaurador atraumático, es utilizado como parte de los programas preventivos de salud pública, por ello es importante evaluar las técnicas de aplicación del material restaurador utilizando cemento ionómero de vidrio de autocurado. Objetivo: Comparar la microfiltración de los cementos ionoméricos Ketac™ Molar Easy Mix e Ionofil Molar® con dos técnicas de aplicación: jeringa centrix y espátula TRA. Materiales y métodos: Estudio experimental in vitro. Se utilizaron 52 dientes de bovino con preparaciones cavitarias. Las muestras se dividieron en 2 grupos según los cementos ionoméricos y según la técnica de aplicación. Se colocó el material restaurador siguiendo las indicaciones del fabricante. Todas las muestras fueron termocicladas, sumergidas en azul de metileno al 0,05% y seccionadas mediante un corte longitudinal. Se evaluó la microfiltración a través del software del esteromicroscopio. Para comparar las técnicas de aplicación según los cementos ionoméricos se utilizaron las pruebas estadísticas de t de Student y la prueba de U de Mann- Whitney. Resultados: La microfiltración de los cementos ionoméricos Ketac TM Molar Easy Mix e Ionofil Molar® según las técnicas de aplicación jeringa centrix y espátula TRA, no mostraron diferencias estadísticamente significativas (valor p>0,05). El cemento Ketac TM Molar Easy Mix y la técnica con la jeringa centrix y su respectiva combinación fueron los que presentaron menor microfiltración. Conclusión: Todos los dientes presentaron microfiltración y entre ellos el grupo KetacTM Molar Easy Mix® con la jeringa centrix mostraron menores valores de microfiltración
7

Estudio del tratamiento de un agua con alto contenido en silicatos de zirconio mediante Microfiltración y Ultrafiltración

Pineda Santos, Alicia 21 July 2008 (has links)
En la presente Tesis Doctoral se ha estudiado la viabilidad del tratamiento de un agua residual con alto contenido de silicatos de zirconio, procedente de una industria de procesado de sólidos, mediante la combinación de los procesos de Microfiltración y Ultrafiltración, con la finalidad de generar un agua con las características adecuadas para ser reutilizada dentro del proceso industrial cerámico. Dentro del proceso industrial se genera un agua residual con un aspecto opaco debido a la presencia de silicato de zirconio, además de contener residuos de polielectrolito que es empleado en la separación del producto final, entre otras sustancias. El tratamiento general de esta agua residual, consiste en un pretratamiento el cual se lleva a cabo por medio de Microfiltración, con el cual se retiene la mayor cantidad de silicatos de zirconio y, un tratamiento aplicando Ultrafiltración para la separación del resto de sustancias presentes en el agua, principalmente el polielectrolito. Para la etapa de Microfiltración se realizaron ensayos de larga duración, en estos ensayos se observó que la calidad del agua obtenida es adecuada para su utilización en el tratamiento, ya que la caracterización del filtrado obtenido muestra que no existe presencia de silicatos de zirconio en el agua; sin embargo, para optimizar este pretratamiento se realizaron ensayos con distintos protocolos de limpieza, llevando a cabo limpiezas periódicas en cada ensayo, y de esta manera prolongar el tiempo de vida media de la membrana de Microfiltración. Posteriormente, para los ensayos de Ultrafiltración, se realizó un estudio exhaustivo para la determinación de la técnica analítica más adecuada para medir la concentración de polielectrolito en el agua. Los ensayos que se realizaron de Ultrafiltración fueron ensayos de larga duración, con el objetivo de concentrar al máximo el polielectrolito, en dichos ensayos se observó que no existe una acumulación de sustancias (específicamente polielectrolito) / Pineda Santos, A. (2005). Estudio del tratamiento de un agua con alto contenido en silicatos de zirconio mediante Microfiltración y Ultrafiltración [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/2601 / Palancia
8

Efecto de dos bebidas refrescantes en la adhesión de brackets. Observación mediante microcopio electrónico de barrido del esmalte intacto y sellado por una resina tras la exposición a dichas bebidas

Navarro Garre, Rául 24 February 2012 (has links)
OBJETIVO: Evaluar el efecto de Coca-Cola® y Schweppes® Limón en la fuerza adhesiva, el adhesivo remanente y la microfiltración debajo de los brackets. Examinar mediante microscopio electrónico de barrido (MEB) el efecto de estas bebidas en el esmalte intacto y esmalte sellado. MÉTODO: Se cementaron 120 brackets en incisivos bovinos y se dividieron 1) grupo control, 2) Coca-Cola®, 3) Schweppes® Limón. Los dientes fueron sumergidos en las bebidas tres veces al día (15 minutos) durante 15 días. La fuerza de adhesión fue medida con una máquina universal de ensayos y el adhesivo remanente, utilizando un equipo de análisis de imagen. La microfiltración en la interfase esmalte-adhesivo y adhesivo-bracket se determinó utilizando azul de metileno. Para las observaciones al MEB se utilizaron 108 dientes. RESULTADOS: No se encontraron diferencias significativas en la fuerza adhesiva y el adhesivo remanente entre grupos. La microfiltración en la interfase esmalte-adhesivo para Coca-Cola® y Schweppes® Limón fue significativamente mayor que para el grupo control. En la interfase adhesivo-bracket la microfiltración de Coca-Cola® fue mayor que el grupo control, mientras que la microfiltración de Schweppes® Limón no difirió significativamente ni de Coca-Cola® ni del grupo control. Las bebidas produjeron erosión del esmalte y pérdida del material adhesivo. / Objective: To evaluate the effect of Coca-Cola® and Schweppes®-Limón on bond strength, adhesive remnant and microleakage beneath brackets. To examine by Scanning Electron Microscope (SEM) the effect of these drinks on intact and sealed enamel. Methods: 120 brackets were bonded to bovine incisors and divided into: 1)Control-group; 2)Coca-Cola®; 3)Schweppes®-Limón. The teeth were submerged in the drinks 3 times/day (15 minutes) during fifteen days. Shear bond strength was measured with a universal test machine, and adhesive remnant using image analysis equipment. Microleakage at the enamel-adhesive and adhesive-bracket interfaces was detected using methylene blue. 108 teeth were used to examine by SEM the effect of the drinks on intact and sealed enamel. Results: No significant differences were found in bond strength and adhesive remnant between groups. Microleakage at the enamel-adhesive interface for Coca-Cola® and Schweppes®-Limón was significantly greater than for the control. At the adhesive-bracket interface microleakage was significantly greater with Coca-Cola® than with the control whilst microleakage with Schweppes®-Limón did not differ significantly from either Coca-Cola® or the control. The drinks produced enamel erosion and loss of adhesive.

Page generated in 0.0444 seconds