• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 55
  • 13
  • 4
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 81
  • 44
  • 26
  • 19
  • 17
  • 16
  • 13
  • 13
  • 11
  • 11
  • 10
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo in vitro da microinfiltração em restaurações de cavidades classe V preparadas com alta rotação e lasers Er:YAG e Er, Cr:YSGG, utilizando-se dois sistemas adesivos / IN VITRO STUDY OF THE MICROLEAKAGE IN CLASS V CAVITIES RESTORATIONS PREPARED WITH AIR TURBINE AND LASERS Er:YAG AND Er,Cr:YSGG, AND BEING USED TWO ADHESIVE SYSTEMS

Vera Lucia Moldes 19 February 2004 (has links)
RESUMO O objetivo deste estudo foi comparar o grau de microinfiltração nas margens gengival e incisal de restaurações classe V frente aos seguintes métodos de preparo: 1) alta rotação, 2) laser – Er:YAG modelo Opus 20 (Opus Dent) e 3) laser – Er,Cr:YSGG modelo Waterlase (Millennium, Biolase). Foram avaliados também os sistemas adesivos Single Bond (3M ESPE) e One-Up Bond F (Tokuyama). Sessenta incisivos bovinos hígidos, extraídos foram divididos em 6 grupos de 10 elementos. As cavidades foram preparadas de acordo com o protocolo a seguir: grupo 1 e 2 utilizando alta rotação, grupo 3 e 5 laser de Er:YAG, grupo 4 e 6 laser de Er,Cr:YSGG. Os espécimes foram restaurados com resina composta Z250 (3M ESPE) com a utilização prévia dos adesivos Single Bond (grupos 1, 3 e 4) e One-Up Bond F (grupos 2, 5 e 6). Após armazenagem em água destilada a 37ºC por 24h, os espécimes foram polidos, termociclados e imersos em solução de nitrato de prata a 50% por 8h. Os espécimes foram incluídos, seccionados em duas porções e revelados à 10min de exposição sob lâmpada phothoflood. Os corpos-de-prova infiltrados foram avaliados em lupa estereomicroscópica com 25 vezes de aumento a fim de detectar o grau de microinfiltração de cada uma das margens. A mais infiltrada foi escolhida para representar o resultado individual de cada corpo-de-prova. Foram realizadas fotos, e encaminhadas a três examinadores utilizando o método de escores 0, 1, 2 e 3. Os dados obtidos foram submetidos à análise estatística através do teste estatístico não paramétrico de Kruskal-Wallis. Na margem gengival houve maior microinfiltração no preparo realizado com laser Er:YAG do que com alta rotação com o sistema adesivo Single Bond. Na margem gengival com os preparos de lasers Er:YAG e Er,Cr:YSGG, observou-se menor microinfiltração com a utilização do sistema adesivo autocondicionante One-Up Bond F. A margem incisal não apresentou diferenças nos graus de microinfiltração para todos os tratamentos. / SUMMARY The aim of this research was compare the microleakage degree in the class V gingival and incisal margins using following preparation methods: 1) air turbine, 2) laser – Er:YAG Opus 20 (Opus Dent) and 3) laser – Er,Cr: YSGG Waterlase model (Millennium, Biolase). Also, the adhesive systems Single Bond (3M ESPE) and One-Up Bond F (Tokuyama) were evaluated. Sixty intact bovine incisives were divided in 6 groups of 10 elements each. The cavities were prepared as follow: groups 1 and 2 using air turbine, groups 3 and 5 laser Er:YAG, groups 4 and 6 laser Er,Cr:YSGG prepare. The specimens were restored with composite resin Z250 (3M ESPE) with previous utilization of the Single Bond (groups 1, 3 and 4) and One-Up Bond F (groups 2, 5 and 6). After storage in distilled water at 37°C, for 24 hours, the specimens were polished, thermocycled and immersed in 50% silver nitrate for 8h. The specimens were included, sectioned in two parts and revealed by means of a 10 min exposure photoflood lamp. The infiltered specimens were evaluated using a stereomicroscope glass with 25X magnification to detect the microleakage degree of each part. The more infiltrate was chosen to represent the individual result of each specimen. Photos were accomplished, and sent to three examinators using the method of scores 0, 1, 2 and 3. The obtained data were submitted to a statistical analysis using the non-parametrical statistic test of Kruskal-Wallis. In the gingival margin there was more microleakage with the prepare accomplished with laser Er:YAG, than that of air turbine with the Single Bond adhesive system. In the gingival margin with the lasers preparations Er:YAG and Er,Cr:YSGG smaller microleakage was observed with the use of self-etching One-Up Bond F adhesive system. The incisal margin did not present differences in the degrees of microleakage for all treatments.
22

Efeito da remoção do colageno na infiltração marginal em restaurações de resina composta utilizando dois sistemas adesivos de frasco unico

Saboia, Vicente de Paulo Aragão 16 February 2001 (has links)
Orientador: Luiz Andre Freire Pimenta / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T00:22:23Z (GMT). No. of bitstreams: 1 Saboia_VicentedePauloAragao_D.pdf: 2377804 bytes, checksum: b83955fe9c76b5de6e7f36a75db01b3f (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar o efeito da remoção do colágeno na infiltração marginal de corante na interface adesiva de restaurações de resina composta utilizando dois sistemas adesivos de frasco único, envelhecidas através de ciclagem térmica e estocagem em água durante 1 ano. Foram usadas 40 raízes de terceiros molares humanos recém-extraídos e armazenados em formol a 10%. A câmara pulpar e o ápice radicular foram vedados com resina composta. Cada raiz recebeu dois preparos cavitários cilíndricos com dimensões de 2 mm de diâmetro por 2 mm de profundidade. Após sorteio, foram criados dois conjuntos de 20 raízes cujas cavidades foram restauradas utilizando-se os adesivos Prime & Bond 2.1 (PB-Dentsply) ou Single Bond (SB-3M). Cada porção radicular recebeu uma restauração pela técnica da hibridização (controle) e outra após o tratamento da dentina com NaOCI (hipoclorito de sódio) a 10% por 60 s para remoção de colágeno (teste). Ficaram estabelecidos 4 grupos de 20 cavidades assim distribuídas: G1(PBSH)-PB sem NaOCI; G2(PBCH)-PB com NaOCI; G3(SBSH)- SB sem NaOCI e G4(SBCH)-SB com NaOCI. Todas as cavidades foram restauradas com resina composta Z 100 (3M) de acordo com as instruções do fabricante. Os espécimes foram submetidos a 5000 ciclos térmicos (5-55 °C) e armazenados em água à 37°C. Após 1 ano, os remanescentes radiculares foram vedados e imersos em solução de azul de metileno a 2% por 4 horas. As restaurações, foram seccionadas no sentido longitudinal da raiz e observadas em lupa estereoscópica com 45 vezes de aumento. De acordo com a penetração do corante nas margens da restauração foram atribuídos escores de 0 a 4, os quais foram tabulados e submetidos ao teste Exato de Fisher. A remoção do colágeno reduziu significativamente os índices de microinfiltração para o adesivo à base de acetona (Prime & Bond 2.1) enquanto que para o adesivo à base de água (Single Bond) este tratamento não influenciou os índices de microinfiltração / Abstract: The aim of this study was to evaluate the effect of collagen removaI on the microleakage of two single-bottle adhesive systems. Forty human third molars were selected and each of them received two preparations on its roots. The roots were randomly assigned to be restored using Prime & Bond 2.1(PB-Dentsply) or Single Bond (SB-3M). One of the cavities in each root was treated with 'H IND. 3¿¿PO IND. 4¿ and the other received an additional treatment with 10% sodium hypochlorite (NaOCI) for 60 s before adhesive application for removaI of collagen layer. Four groups were created: G1(PBSH)-PB without NaOCI; G2(PBCH)-PB with NaOCI; G3(SBSH)-SB without NaOCI and G4(SBCH)-SB with NaOCI. All the cavities were restored with Z 100 restorative resin (3M). The specimens were submitted to 5,000 thermal cycles (5-55 °C) and stored in 37°C water for 1 year. After this time the specimens were coated with a varnish except for 1 mm of tooth structure surrounding the restoration and immersed in 2% blue methylene for 4 hours. After rinsing, the restorations were sectioned and two independent observers, using a light microscopy at x45 magnification, scored (0 - 4) the microleakage at the interface between restorative material and tooth. The scores were submitted to Fisher's Exact Test and the results showed that collagen removal reduced significantly the microleakage for Prime & Bond 2.1 and had not effect on microleakage for Single Bond / Doutorado / Dentística / Doutor em Clínica Odontológica
23

Análise do selamento marginal de restaurações realizadas após preparo cavitário com laser de Er;Cr:YSGG utilizando diferentes parâmetros em dentina hígida / Analysis of the marginal sealing of restorations after cavity preparation performed with laser Er,Cr:YSGG using different parameters in dentin

Angela Majolo Vigorito 30 March 2010 (has links)
O objetivo deste trabalho foi avaliar a microinfiltração de restaurações classe V em preparos de cavidades obtidos com diferentes potências do laser Er;Cr:YSGG e as cavidades preparadas convencionalmente (ponta diamantada em alta rotação). Sessenta amostras de dentina foram divididas em seis grupos (n = 10). O primeiro grupo serviu como um controle padronizado com preparo de ponta diamantada (G1), os demais grupos foram irradiados com laser de Er;Cr:YSGG com diferentes parâmetros: G2- 2,0W; G3- 2,25W; G4- 2,5W; G5- 2,75W; G6- 3,0W. Este laser emite comprimento de onda de 2,78m e tem largura de pulso de 140m e taxa de repetição fixa de 20Hz. A energia do laser foi entregue através de um sistema de fibra óptica para um terminal de ponta de safira de 6mm de comprimento e 600m de diâmetro, utilizando modo não contato. O sistema adesivo autocondicionante (Clearfil SE Bond- Kuraray, Japan) e a resina composta microhíbrida (Z-250, 3M/ESPE, St.Paul, USA) foram utilizados para compor os corpos de prova. Após as restaurações, os espécimes foram submetidos a teste de microinfiltração com solução de azul de metileno a 2% em pH 7,0, durante 4 horas, a 37°C. Os resultados mostraram não haver di ferença estatística (p=0,203) entre os grupos experimentais em que os preparos das cavidades foram realizados com ponta diamantada ou com diferentes parâmetros de energia do laser de Er;Cr:YSGG. A partir do presente estudo, pode-se concluir que a microinfiltração foi semelhante em todos os grupos experimentais independente do método de preparo cavitário de classe V usado - laser Er;Cr:YSGG ou ponta diamantada. / The aim of this work was to evaluate dye penetration of Class V restorations in cavity preparations obtained with different power setting of an Er;Cr:YSGG laser or with diamond bur and high-speed handpiece. Sixty samples of dentin were divided into six groups (n=10). The first group served as a control with standardized diamond bur cut (G1); the other groups were irradiated with an Er;Cr:YSGG laser with different power parameters: G2- 2.0W; G3- 2.25W; G4- 2.5W; G5- 2.75W; G6- 3.0W. This laser emitting at a wavelength of 2.78m and had pulse duration of 140m and fixed pulse repetition rate of 20Hz. Laser energy was delivered through a fiberoptic system to a sapphire tip terminal 6mm long and 600m in diameter, using non-contact mode. Self-etching adhesive system (Clearfil SE Bond- Kuraray, Japan) and microhybrid composite resin (Z-250, 3M/ESPE, St. Paul, USA) were used to compose the samples. After restoration, specimens were submitted to a microleakage test with 2% methylene blue solution at pH 7.0, for 4 h at 37°C. Results showed no statistical difference (p=0.203) between experimental groups in which cavity preparations were performed by diamond bur or different power settings of Er;Cr:YSGG laser. From the present study, it can be concluded that microleakage were similar to all experimental groups irrespective of the Class V cavity preparation method used - Er;Cr:YSGG laser system or diamond bur.
24

Avaliação 'in vitro' da Microinfiltração na Interface da Parede Gengival das Caixas Proximais em Cavidades Classe II de Molares Decíduos, Restaurados com Resina Composta Auto e Fotopolimerizável / ANALYSIS “IN VITRO” OF MICROLEAKINGS ON GUM’S EDGES OF THE APPROXIMAL BOXES IN CLASS II CAVITIES OF DECIDUOUS MOLARS, RESTORED WITH AUTO AND LIGHT-CURED COMPOSITE RESIN

Alessandro Leite Cavalcanti 07 November 1997 (has links)
A finalidade deste estudo foi avaliar “in vitro” a microinfiltração marginal presente na interface da parede gengival de cavidades classe II em molares decíduos, restaurados com resina composta (auto e fotopolimerizável), com a utilização de uma solução corante. Os preparos cavitários apresentavam a parede gengival em esmalte, sendo restaurados segundo 4 diferentes técnicas: resina composta fotopolimerizável; resina composta autopolimerizável; técnica mista (resina composta auto e fotopolimerizável) e ionômero de vidro/resina composta. Em seguida, procedeu-se à ciclagem térmica (5oC e 55oC, 700 ciclos), impermeabilização, imersão em solução corante e seccionamento. A avaliação quanto à microinfiltração, foi feita seguindo-se uma escala preestabelecida (graus de 0 a 4). Após a análise estatística dos resultados, concluiu-se que todos os grupos apresentaram microinfiltração, em graus variados, todavia os grupos que utilizaram a técnica mista e o ionômero/resina fotopolimerizável apresentaram os menores graus de infiltração, e que não se observou microinfiltração na interface resina composta autopolimerizável/fotopolimerizável. / The purpose of this study was evaluation “in vitro” of marginal microleakings, present on gum’s edges of class II cavities of deciduous molars, restored with composite resin (auto and light-cured), with the use of a staining solution to verify the leaking. Cavities prepared presented enamel on gum’s edges and were restored according to four different techniques: lightcured composite resin; auto-cured composite resin; mixed technique (auto and light-cured composite resin) and glass-ionomer/composite resin. Next, we proceeded to thermo-cycling (5°C and 55°C, 700 cycles), turning impermeable, immersion in staining solution and slicing. The microleaking evaluation was done according to a pre-established scale (from 0 a 4 degrees). After the statical analysis of the results, it was concluded that all the groups presented microleaking, in varying degrees. However, the groups which used the mixed technique and light-cured resin presented the smallest levels of leaking, and microleaking was not observed on the auto-cured composite resin/light-cured composite resin edge.
25

Avaliação in vitro da microinfiltração bacteriana em implantes do tipo hexágono externo, hexágono interno e cone morse / Evaluation in vitro of bacterial microleakage in external hexagonal, internal hexagonal and morse-taper dental implants

Gustavo Henrique Diniz Pimentel 01 July 2009 (has links)
Três dos principais tipos de implantes disponíveis no mercado são: o hexágono externo, o hexágono interno e o cone morse. Um microespaço, presente entre o implante e o intermediário protético, permite a penetração bacteriana e colonização do interior do implante. Esse microespaço, juntamente com a colonização bacteriana, tem sido associado com a perda óssea ao redor dos implantes, característica da periimplantite. O objetivo desse trabalho foi comparar a possível contaminação bacteriana nesses três tipos de implantes, em um período de 24 horas, semelhante ao que acontece na condição de carga imediata. Para tal, foram utilizados 10 implantes de cada tipo, com seus respectivos intermediários protéticos, sendo o Grupo 1 de implantes Hexágono Externo (HE), Grupo 2 de Hexágono Interno (HI) e Grupo 3 de Cone Morse (CM). No interior de cada implante foram inoculados 2L de meio de cultura (BHI). Os espécimes foram depositados individualmente em tubos de ensaio contendo 4 mL de BHI estéril. Após um teste de esterilidade, 100L de BHI contendo Enterococcus faecalis foram inoculados em cada tubo. Após 24 horas em meio contendo bactérias, os espécimes foram removidos, desinfectados e reabertos. Com um cone de papel estéril, o material do interior dos implantes foi coletado e colocado em meio de cultura para avaliar a possível passagem de bactérias do meio externo para o interno dos implantes. O teste foi repetido por mais duas vezes (Teste I, II e III), com o cuidado de se lavar e esterilizar em autoclave os espécimes. Os resultados foram tabulados e o teste exato de Fisher foi aplicado com o nível de significância de 5%. Os resultados do teste I mostraram a contaminação de 8 implantes HE, 4 implantes HI e 2 implantes CM, sendo a contaminação no grupo HE estatisticamente significante maior que nos grupos HI e CM; o teste II mostrou a contaminação de 7 implantes HE, 4 implantes HI e 4 implantes CM, não havendo diferenças estatisticamente significantes; o teste III mostrou a contaminação de 10 implantes HE, 7 implantes HI e 3 implantes CM, revelando diferenças estatisticamente significantes entre o grupo HE e CM. Concluise, portanto, que após um período de 24 horas, houve contaminação bacteriana em todos os grupos avaliados, sendo estatisticamente maior no grupo 1. / Three main types of implants available in the market are: external hexagonal, internal hexagonal and morse-taper. A microgap, present between the implant and the abutment, enables bacterial penetration and colonization of the interior of the implant. This microgap, associated with bacterial colonization, has been related with bone loss around the implants, present in periimplantitis . The aim of this study was to compare the possible bacterial contamination in these three types of implants in a 24 hour period, similarly with immediate loading. 10 implants of each type, with their abutments, were used. The implants of Group 1 were external hexagonal (HE) type, Group 2 were Internal Hexagonal (HI) type and Group 3, morse-taper type(MC). 2 µL of brain-heart infusion (BHI) broth were added into each implant. The specimens were placed individually in glass culture tubes containing 4 mL of sterile BHI broth. After a test to assure sterility, 100 µL of BHI broth containing Enterococcus faecalis were inoculated in each tube. After 24 hours, the specimens were removed, disinfected and reopened. With a sterile paper cone, the material inside the implants were collected and placed in BHI to evaluate the possible passage of bacteria from the outside to the internal side of the implant. The test was repeated two times more (Test I, II and III). The Fisher exact test was used to compare the number of contaminated implants in each group, at a significance level of 5%. The results of test I showed contamination of 8 HE implants, 4 HI implants and 2 CM implants. The contamination in the HE group was statistically higher than CM and HI groups. Test II revealed contamination of 7 HE implants, 4 HI implants and 4 CM implants. No statistically significant differences were observed. Test III showed contamination of 10 HE implants, 7 HI implants and 3 CM implants, revealing statistically significant differences between HE and CM groups. It can be concluded that after a period of 24 hours, there was bacterial leakage in all groups studied, with statistically higher contamination in group 1.
26

Avaliação in vitro da infiltração de fluidos pela interface implante-pilar intermediário de três sistemas com conexão do tipo cone Morse e da capacidade de vedação de um material / In vitro evaluation of fluid penetration at the implant-abutment interface of three cone Morse systems and sealing ability of a material

Flavia Maria Lopes de Moraes 27 September 2010 (has links)
A infiltração de fluido e bactérias nos espaços internos dos implantes foi observada em pilares intermediários parafusados, tanto em situações in vitro quanto in vivo devido à microfenda existente entre o implante e o pilar intermediário. Esse fato pode estar relacionado com a inflamação dos tecidos periimplantares e também com a produção de mau odor. O objetivo do presente estudo in vitro foi avaliar e comparar a ocorrência de infiltração de fluidos pela interface implante-pilar intermediário em três sistemas de implante com conexão do tipo cone Morse, e a capacidade de vedação de um adesivo anaeróbico, utilizando o radioisótopo Tecnécio-99m como marcador. Na primeira etapa, dez conjuntos implante-pilar intermediário de cada sistema foram imersos em solução contendo esse marcador, após a aplicação do torque recomendado pelo fabricante, e foram mantidos em pressão constante de 2 atm por um minuto. Na segunda etapa, um adesivo anaeróbico foi aplicado no pilar intermediário antes do mesmo ser parafusado ao seu respectivo implante. Após a aplicação da pressão, o infiltrado presente no interior dos implantes foi coletado com pontas de papel. Esse material foi depositado em tubos de ensaio para posterior leitura da radioatividade presente. A infiltração de fluido pela interface implante-pilar intermediário mostrou ser um fenômeno mensurável em todas as amostras dos três sistemas de implante com conexão do tipo cone Morse testados. A quantidade de infiltrado variou entre os sistemas e entre as amostras. A inconstância das amostras foi observada em todos os sistemas, no entanto, foi observado que o valor de infiltrado encontrado no Grupo 1 foi significantemente maior (p<0,05) do que o encontrado no Grupo 2, e não houve diferença estatística significante entre os Grupos 1 e 3, e entre os Grupos 2 e 3. Também foi observado que, com o uso do adesivo anaeróbico, os sistemas apresentaram diminuição da quantidade de infiltrado, sendo que a análise estatística dos valores obtidos com e sem o seu uso, mostraram significância a 1%. Além disso, com o uso do adesivo anaeróbico os três sistemas de implante testados passaram a ter comportamento semelhante, não tendo sido encontrada diferença estatística significante entre eles (p=0,5451). Considerando os limites deste estudo, pode-se concluir que os três sistemas de implante com conexão do tipo cone Morse testados permitiram a passagem de fluido do meio externo para o interior dos implantes, e que o material testado não foi capaz de impedir a penetração de fluido, apesar de ter reduzido significantemente a quantidade de infiltrado em todos os sistemas. / It has been observed that in implants with screw-retained abutments, in in vitro as well as in vivo conditions, bacteria and fluids can penetrate the inner implant space as consequence of an existing microgap at the implant-abutment interface. This fact can be related to peri-implant tissue inflammation and malodor. The aim of the present study was to evaluate and compare the occurrence of fluid penetration throught implant-abutment interface in three cone Morse implant systems and sealing ability of an anaerobic adhesive using a radioisotope as trace. In the first phase, ten implant-abutment sets of each system were immersed in a solution with radioisotope, after manufacture recommended torque application. All assemblies were kept in a constant pressure of 2 atm for one minute. In the second phase, an anaerobic adhesive was applied before the abutments been torque-tightened to the same implant. After the pressure application, material inside implant bodies was colleted using a paper cone that was transferred to tubes for posterior verification of radioactivity. Fluid penetration at the implant-abutment interface was seen to be a recordable phenomenon in each assembly of the three cone Morse systems tested in this study. The quantity of infiltrated varied between systems and assemblies. The variable of the samples was observed in all systems, however, it was noted that the value of infiltrate found in Group 1 was significantly higher than that found in Group 2, and there was no statistical significant difference between the groups 1 and 3, and between groups 2 and 3. It was also noted that, using the adhesive anaerobic, the implant systems showed reduce infiltrate, and statistical analysis presented significance to 1%. Moreover, with the use of anaerobic adhesive, all three implant systems tested presented similar pattern, and no significant statistical difference was found (p=0,5451). Considering the limits of this study, the following conclusions can be drawn: the three cone Morse implant systems tested allowed the passage of fluid from external to the inside of the implants, and that the material tested was not capable of preventing the fluid penetration, despite having reduced significantly the amount of infiltrate in all systems.
27

"Soluções aquosas de nitrato de prata: características e desempenho nos testes de infiltração" / Aqueous silver nitrate solutions: characteristics and performance in leakage tests

José Ferreira Costa 08 December 2005 (has links)
Soluções de nitrato de prata são freqüentemente usadas em testes de micro e nanoinfiltração, apesar de nem todas as suas características estarem definidas claramente na literatura. Neste estudo foram avaliadas soluções aquosas de nitrato de prata quanto ao pH e à quantidade de prata iônica (ppm) em várias concentrações, bem como o desempenho dessas soluções em testes de microinfiltração realizados em dentes decíduos e permanentes. Numa primeira fase foi analisado o pH (pHmetro digital) de solução a 50% (p/v), tendo como variáveis a pureza da água, a marca comercial do sal, a cor do frasco, e a idade pós-preparo. Posteriormente, avaliou-se a quantidade de prata iônica, por espectrometria de emissão atômica, presente nas soluções (1%, 5%, 25% e 50%) ao longo de 168 horas de armazenagem. Em cavidades de classe V, confeccionadas nas faces vestibular e lingual/palatina de molares, foram aplicados dois sistemas adesivos (OptiBond FL ou OptiBond Solo Plus SE). Após a restauração (Filtek Z-250) foi determinado o valor médio de microinfiltração (mm) para diversas concentrações e idade pós-preparo das soluções. Os dados obtidos foram tratados por análise de variância e teste de Tukey (a=0,05). As soluções analisadas na primeira etapa apresentaram pH médio entre 7,9±2,2 a 11,8±0,9, e houve diferenças significativas para todas as variáveis. O teor médio de prata iônica apresentou diferenças significativas para o fator Concentração (4,75±0,5 a 1% e 293±15,3ppm a 50%); porém, não houve diferença para o fator Idade. Nos testes de microinfiltração houve diferença significante apenas para o fator Adesivo (p<0,01); os demais fatores e as interações não apresentaram diferenças significativas. Com base nos resultados obtidos neste estudo pode-se concluir que: 1) o pH de soluções aquosas de nitrato de prata varia de neutro a alcalino; 2) a quantidade de prata iônica e o pH se mantêm estáveis por até 168h; 3) a concentração e a idade pós-preparo das soluções não interferiram nos valores médios de microinfiltração; 4) o sistema adesivo OptiBond FL apresentou menores valores de microinfiltração, em dentes permanentes e decíduos / Silver nitrate solutions are frequently used in micro and nanoleakage tests, although not all of their characteristics are clearly defined in the literature. In this study an assessment was made of aqueous silver nitrate solutions as regards pH and the amount of ionic silver (ppm) in various concentrations, as well as the performance of these solutions in microleakage tests performed in primary and permanent teeth. In the first phase the pH (digital pH meter) of a 50% (w/v) solution was analyzed, having water purity, commercial brand of the salt, the color of the flask, and the storage time as variables. Afterwards, the amount of ionic silver present in the solutions (1%, 5%, 25% and 50%) was evaluated by atomic emission spectrometry, throughout 168 hours of storage. In Class V cavities made on the vestibular and lingual/palatal faces of molars, two adhesive systems were applied (OptiBond FL or OptiBond Solo Plus SE). After restoration (Filtek Z-250) the mean microleakage value (mm) was determined for the various concentrations and post-preparation time of the solutions. The data obtained were submitted to analysis of variance and the Tukey test (a=0.05). The solutions analyzed in the first stage had a mean pH ranging between 7.9±2.2 and 11.8±0.9, and there were significant differences for all the variables. The mean ionic silver content presented with significant differences for the factor Concentration (4.75±0.5 at 1% and 293±15.3 ppm at 50%); but there was no difference for the factor Time. In the microleakage tests there was significant difference only for the factor Adhesive (p<0.01); the other factors and the interactions did not present with any significant differences. Based on the results obtained in this study, it may be concluded that: 1) the pH of aqueous silver nitrate solutions varies from neutral to alkaline; 2) the amount of ionic silver and pH remained stable for up to 168h; 3) the concentration and the post-preparation time of the solutions did not interfere with the mean microleakage values; 4) the adhesive system OptiBond FL presented with the lowest microleakage values in both permanent and primary teeth
28

"Influência do modo de fotoativação e da distância da fonte de luz no grau de conversão e microinfiltração de um compósito" / Influence of the photoactivation mode and light-tip distance on the degree of conversion and microleakage of a composite

Nivea Regina de Godoy Froes 03 June 2005 (has links)
O objetivo do presente trabalho foi avaliar o grau de conversão, bem como o padrão de microinfiltração, de uma resina composta frente às seguintes variações nas condições de fotopolimerização: intensidade de luz X tempo e distância fonte de luz-superfície do compósito. Espécimes cilíndricas do material Esthet-X A2 (5mm de diâmetro e 2mm de altura) foram polimerizadas de acordo com os seguintes parâmetros: 600mW/cm2 por 40s, 400mW/cm2 por 60s ou 200mW/cm2 por 20s + 500mW/cm2 por 40s; distância fonte-resina de 0, 3 ou 7mm, resultando em nove grupos experimentais (n=3). A densidade de energia (intensidade X tempo) para todos os grupos foi de 24J/cm 2 . Os corpos de prova foram então submetidos à análise através do espectrofotômetro FT-Raman (RFS 100/S, Bruker; resolução de 4 cm -1 e 64 scans) para o cálculo da quantidade de duplas ligações remanescentes no material, tanto da face irradiada (FI) como da não-irradiada (FNI). A razão entre os picos relativos às bandas de 1610 e 1640 cm -1 (duplas ligações aromáticas e alifáticas, respectivamente) foi utilizada para estimar o grau de conversão. A análise estatística (ANOVA, com a<0,05, e teste de Tukey) mostrou significância dos fatores distância da fonte, face analisada e da interação modo de irradiação X distância. As médias de grau de conversão (em%) para 600, 400 e 200+500mW/cm2 foram respectivamente de 58,29 (±2,87); 57,99 (±2,94) e 58,32 (±2,46). Para as distâncias de 0, 3 e 7mm os valores obtidos foram: 59, 13 (±2,32); 58,61 (±3,08) e 56,85 (±2,24). As faces irradiadas apresentaram grau de conversão médio de 59,01 (±2,56) enquanto as não irradiadas de 57,40 (±2,67). Para o teste de microinfiltração, cavidades classe V foram confeccionadas em 90 incisivos bovinos. O substrato foi condicionado com ácido fosfórico a 37% durante 15 segundos, lavado e seco para a remoção do excesso de água, deixando-se, entretanto, a dentina úmida. Foi então aplicado o sistema adesivo Prime & Bond NT (Dentsply/Caulk). O preenchimento da cavidade foi feito em um só incremento, seguindo o mesmo padrão de polimerização proposto para o estudo do grau de conversão. Após a restauração, os dentes foram ar mazenados e então submetidos ao protocolo de teste com nitrato de prata. Foi utilizado para a análise dos escores de microinfiltração o teste de Kruskal -Wallis, não-paramétrico. Assim, foi observado que o modo de irradiação em dois passos causou uma diminuição na microinfiltração; tal redução também foi observada com o aumento da distância fonte de luz-compósito, com exceção dos grupos irradiados com 400mW/cm2. As médias dos escores de microinfiltração variaram entre 0,25 (±0,17) para o grupo com irradiação em dois passos, 7mm de distância e 2,0 (±0,96) para o grupo de 600mW/cm, 0mm. Não houve correlação entre grau de conversão e microinfiltração, bem como não houve influência da densidade de energia sobre esses testes. Por outro lado, pode-se concluir que a forma de fornecimento da energia na fotoativação correlaciona-se com a conversão e a microinfiltração. / The aim of this study was to assess the degree of conversion and microleakage of a restorative composite in relation to the following variations on the photoactivation conditions: light intensity x exposure time and distance from the light source. Degree of conversion was analyzed on cylindrical specimens (5 mm in diameter and 2 mm in height), photoactivated according to one of the following methods: 600mW/cm 2 x 40s; 400 mW/cm 2 x 60 s or 200 mW/cm 2 x 20s, followed by 500 mW/cm 2 x 40s. The distance from the light source was also variable: 0, 3 or 7 mm. Therefore, nine experimental groups (n=3) were obtained. Energy density (power density x exposure time) for all groups was kept constant (24 J/cm 2 ). Specimens were then submitted to FT-Raman analyses (RFS 100/S, Burker, 4cm -1 , 64 scans) for remaining double-bonds estimative, both on the top and on the bottom surfaces. The relation between 1610 and 1640 cm -1 peaks (aromathic and aliphatic bonds, respectively) was taken into account. Statistical analyses (ANOVA and Tukey test, a=0,05) found significance for the distance from the light source, the surface considered and the interaction between photoactivation mode and distance from the light source. Degree of conversion (in %) was 58,29 (±2,87), 57,99 (±2,94) and 58,32 (±2,46) for 600, 400 and 200+500 mW/cm 2 , respectively. For source distances of 0, 3 and 7 mm, values were 59,13 (±2,32) , 58,61 (±3,08) and 56,85 (±2,24), respectively. Top surfaces showed degree of conversion of 59,01 (±2,56), while for the bottom surface it was 57,40 (±2,67). For the microleakage test, the same composite was used for the restoration of class V cavities, made in 90 bovine incisors. The substrate was conditioned for 15 s with phosphoric acid (37%), then rinsed and gently dried. Prime & Bond NT (Dentsply/ Caulk) was then applied, according to the manufacturer’s instructions. Preparations were restored in bulk and photoactivated according to the procedures described for the degree of conversion analyses. The teeth were then stored for 24 in distilled water (37ºC) before being submitted to the silver-nitrate microleakage protocol. The results were analyzed using scores, submitted to the Kruskall-Wallis test. It could be observed that the two-step irradiation mode lead to less microleakage, when compared to the continuous modes. With exception to the specimens irradiated with 400mW/cm 2 , higher microleakage was observed for smaller distances from the light source. Means for the microleakage scores ranged from 0,25 (±0,17) for the two-step groups, 7mm from the light source to 2,0 (±0,96) for 600mW/cm 2 , 0mm. Power density did not influence neither the degree of conversion nor the microleakage. It could be concluded that photoactivation mode has an influence on the degree of conversion and on the microleakage.
29

An in-vitro study assessing the effect of smear layer on root canal microleakage

Elnour, Mutasim Hassan January 2008 (has links)
>Magister Scientiae - MSc / The aim of this study was to compare the sealing ability of AH Plus sealer to the canal wall in the presence and absence of the smear layer.
30

Efficacy of gapseal® in preventing microleakage at the dental implant abutment interface

Badi Mohamed, Hadeel Mohamed January 2021 (has links)
Magister Chirurgiae Dentium (MChD) / Dental implants have proven to be a success in the past decades, however the inevitable presence of microgaps at the implant abutment interface leading to microleakage is still a distressing concern. Microbial leakage can lead to peri-implant disease and bone loss and reduces implants' success rates. Measures to decrease the effect of the microgap were introduced; amongst them is the application of silicone sealing gels, such as GapSeal®.

Page generated in 0.0395 seconds