• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 267
  • 99
  • 97
  • 80
  • 23
  • 15
  • 15
  • 11
  • 6
  • 5
  • 4
  • 4
  • 3
  • 2
  • 1
  • Tagged with
  • 710
  • 258
  • 216
  • 151
  • 137
  • 113
  • 92
  • 71
  • 69
  • 60
  • 56
  • 54
  • 53
  • 50
  • 48
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Signatures of a 4pi periodic Andreev bound state in topological Josephson junctions / Signatures d'un mode lié d'Andreev 4pi périodique dans des jonctions Josephson topologiques

Le calvez, Kévin 12 April 2017 (has links)
Les isolants topologiques 3D sont un nouvel état de la matière décrit par un volume iso-lant électriquement et recouvert par des états de surface métalliques. Une jonction Joseph-son topologique (TJJ) formée autour de ces états de surface peut théoriquement contenirun mode lié d’Andreev ayant une périodicité doublée par rapport aux modes liés d’An-dreev conventionnels 2p périodiques. Le mode d’Andreev 4p périodique serait la briqueélémentaire de l’ordinateur quantique topologique. Ainsi, nous étudions la dynamique dece mode particulier lors de mesures de Shapiro sur des jonctions Josephson fabriquées surdes isolants topologiques à base de bismuth.A?n d’identi?er les e?ets d’un mode 4p-périodique dans une mesure de Shapiro, nousutilisons un model phénoménologique permettant de simuler la caractéristique courant-tension d’une TJJ lors de telles mesures. Nous prédisons deux signatures du mode 4p-périodique et estimons leur robustesse face aux e?ets de chau?age par e?et Joule et face àun modèle d’empoisonnement thermiquement activé du mode 4p-périodique.Par des mesures de Shapiro, nous étudions la dynamique des TJJ basées sur le matériausimple qu’est le Bi2Se3. L’observation des deux mêmes signatures précédemment anticipéespar nos simulations, à savoir un ordre d’apparition non conventionnel des pas de Shapiroainsi que la persistance d’un supercourant à la fermeture du plateau de Shapiro n = 0prouve la présence d’un mode 4p-périodique.Notre étude s’est également portée sur un autre isolant topologique le BiSbTeSe2. Nousavons e?ectué sa croissance par cristallisation liquide-solide et avons mis en évidence,par des mesures d’interférométrie supraconductrice une supraconductivité de surface sanstransport électronique par le volume. / Three dimensional topological insulators (3D TI) are a new state of matter composedof an electrically insulating bulk covered by metallic surface states. Theoretically, a topo-logical Josephson junction composed of these surface states can host an Andreev Boundstate (ABS) that has twice the periodicity of the conventional 2p periodic ABSs. The4p periodic ABS is expected to be the building block of topological quantum computing.Therefore, we study the dynamic of this particular ABS by performing Shapiro measure-ment on Josephson junctions built with bismuth based 3D TI.To identify the e?ects of a 4p periodic ABS in a Shapiro measurement, we use a phe-nomenological model that simulates the voltage-current characteristics of a TJJ. We predicttwo signatures of the 4p periodic ABS and estimate their robustness against Joule heatingand thermally activated quasiparticle poisoning of the 4p periodic mode.We study the Josephson junctions dynamics by performing Shapiro measurements onjunctions built on Bi2Se3. We observe the two previously anticipated signatures, whichare the non-conventional appearance order of the Shapiro steps and the remaining of asupercurrent at the closing of the Shapiro step n = 0. They prove the presence of a 4pperiodic ABS.We also study the topological insulator BiSbTeSe2 that we have grown by using themelting growth method. By superconducting interferometric measurements, we show asuperconducting surface transport without bulk electronic conduction.
212

A Liquid-Helium-Free High-Stability Cryogenic Scanning Tunneling Microscope for Atomic-Scale Spectroscopy

Hackley, Jason 18 August 2015 (has links)
This dissertation provides a brief introduction into scanning tunneling microscopy, and then Chapter III reports on the design and operation of a cryogenic ultra-high vacuum scanning tunneling microscope (STM) coupled to a closed-cycle cryostat (CCC). The STM is thermally linked to the CCC through helium exchange gas confined inside a volume enclosed by highly flexible rubber bellows. The STM is thus mechanically decoupled from the CCC, which results in a significant reduction of the mechanical noise transferred from the CCC to the STM. Noise analysis of the tunneling current shows current fluctuations up to 4% of the total current, which translates into tip-sample distance variations of up to 1.5 picometers. This noise level is sufficiently low for atomic-resolution imaging of a wide variety of surfaces. To demonstrate this, atomic-resolution images of Au(111) and NaCl(100)/Au(111) surfaces, as well as of carbon nanotubes deposited on Au(111), were obtained. Other performance characteristics such as thermal drift analysis and a cool-down analysis are reported. Scanning tunneling spectroscopy (STS) measurements based on the lock-in technique were also carried out and showed no detectable presence of noise from the CCC. These results demonstrate that the constructed CCC-coupled STM is a highly stable instrument capable of highly detailed spectroscopic investigations of materials and surfaces at the atomic-scale. A study of electron transport in single-walled carbon nanotubes (SWCNTs) was also conducted. In Chapter IV, STS is used to study the quantum-confined electronic states in SWCNTs deposited on the Au(111) surface. The STS spectra show the vibrational overtones which suggest rippling distortion and dimerization of carbon atoms on the SWCNT surface. This study experimentally connects the properties of well-defined localized electronic states to the properties of their associated vibronic states. In Chapter V, a study of PbS nanocrystals was conducted to study the effect of localized sub-bandgap states associated with surface imperfections. A correlation between their properties and the atomic-scale structure of chemical imperfections responsible for their appearance was established to understand the nature of such surface states. This dissertation includes both previously published/unpublished and co-authored material.
213

Estudo das propriedades mecânicas de misturas asfálticas por microscopia de força atômica / Mechanical properties of asphalt mixtures sudied by Atomic Force Microscopy

Costa, Erivelton Façanha da January 2011 (has links)
COSTA, Erivelton Façanha da. Estudo das propriedades mecânicas de misturas asfálticas por microscopia de força atômica. 2011. 131 f. Tese (Doutorado em Física) - Programa de Pós-Graduação em Física, Departamento de Física, Centro de Ciências, Universidade Federal do Ceará, Fortaleza, 2011. / Submitted by Edvander Pires (edvanderpires@gmail.com) on 2015-05-05T21:11:07Z No. of bitstreams: 1 2011_tese_efcosta.pdf: 9690898 bytes, checksum: 515b97b02ebfcf8c3652b217cd15491b (MD5) / Approved for entry into archive by Edvander Pires(edvanderpires@gmail.com) on 2015-05-07T16:57:29Z (GMT) No. of bitstreams: 1 2011_tese_efcosta.pdf: 9690898 bytes, checksum: 515b97b02ebfcf8c3652b217cd15491b (MD5) / Made available in DSpace on 2015-05-07T16:57:29Z (GMT). No. of bitstreams: 1 2011_tese_efcosta.pdf: 9690898 bytes, checksum: 515b97b02ebfcf8c3652b217cd15491b (MD5) Previous issue date: 2011 / The rheological study of asphalt binders is of great importance for determining its performance in paving construction. Usually, rheological parameters are obtained by a Dynamic Shear Rheometer (DSR). The aim of this work is to study the rheological properties of bitumen using an Atomic Force Microscope (AFM). So, a computational tool caled FVLOAD was used for imaging processing. Five kinds of mathematical models were used in order to analise the force curves colected through AFM: the slope analysis, the Young´s model, the adesion model, the FIEL model (Force Integration to Equal Limits) and the work difference model. Three samples were studied: pure bitumen 50/70, bitumem 50/70 doped with 4% of EVA and bitumem 50/70 doped with 4,5% of SBS. Very thin lms of these materials were prepared on glass slides and lead to an AFM for imaging. The area studied on the sample surface was of 50 m x 50 m. There were colected 1024 force curves for each image. The indentations were carried out in four frequencies: 0,5 Hz, 5 Hz, 14 Hz e 28 Hz. The curves colected were analyzed with the FVLOAD program and once the elastic properties were calculated, they were compared to those obtained in the Dynamic Shear Rheometer. / O estudo reológico do Cimento Asfáltico de Petróleo (CAP) é de fundamental importância para a determinação de sua performance na fabricação de estradas. Usualmente os parâmetros reológicos deste tipo de material são obtidos em ensaios dinâmicos através de um reômetro de cisalhamento. O presente trabalho tem por objetivo estudar as propriedades reológicas do CAP através da técnica de espectroscopia de força utilizando um microscópio de força atômica. Para isso, foi utilizada uma ferramenta computacional desenvolvida para o processamento das imagens de microscopia de força chamada de FVLOAD. Cinco análises foram realizadas com os dados das curvas de força: análise de slope, análise do módulo elástico ou módulo de Young, análise de adesão do filme de CAP, análise FIEL (Force Integration to Equal Limits), Work Difference e Adesão. Três amostras foram utilizadas neste estudo: CAP puro 50/70, CAP com 4% de EVA e CAP com 4,5% de SBS. Filmes dos três tipo de CAP foram confeccionados em lamínulas de vidro e levados ao microscópio de força atômica para obtenção dos dados das curvas de força sobre uma área de 50 μm x 50 μm. Para cada imagem foram coletadas 1024 curvas de força. As indentações com a sonda AFM foram executadas em quatro frequências: 0,5 Hz, 5 Hz, 14 Hz e 28 Hz. Finalizadas as aquisições de dados, estes foram processados no programa FVLOAD. Extraído o módulo elástico das amostras em cada frequência, os dados foram comparados com aqueles obtidos em ensaios dinâmicos através do reômetro de cisalhamento dinâmico.
214

Modélisation multidimensionnelle des interactions électrostatiques pointe/diélectrique en microscopie à champ proche / Multidimensional modeling of electrostatic interactions between the tip and dialectric in near field microscopy

Boularas, Abderrahmane 13 May 2015 (has links)
Les techniques de microscopie en champ proche se sont fortement diversifiées au cours des dernières années et ne sont plus désormais cantonnées aux seuls laboratoires experts dans le domaine mais sont exploitées plus largement par les spécialistes des matériaux et des 'micro-' ou 'nano-'objets. Pour ce qui concerne les matériaux diélectriques, des techniques dérivées de la microscopie à force atomique -AFM-, telles que la microscopie à force électrostatique -EFM, ou à force de Kelvin -KFM, permettent d'obtenir de nouvelles informations, à l'échelle nanométrique, sur l'état de charge des isolants et sur leur capacité à stocker/dissiper les charges. Cependant, ces techniques ne permettent pas de connaître précisément la répartition spatiale de la charge en latéral et en profondeur dans les matériaux isolants, données indispensables pour une meilleure compréhension des phénomènes de transport et de piégeage de charges. C'est pourquoi, nous nous sommes intéressés aux courbes de forces électrostatiques comme nouvel outil susceptible de permettre la localisation de la charge. L'objectif de la thèse est donc de comprendre le lien entre l'allure de la courbe de force et le positionnement spatial de la charge dans le matériau. Pour ce faire, deux études sont menées en parallèle : une étude expérimentale et une étude par modélisation numérique. Les travaux de recherche sont focalisés principalement sur la partie simulation de la sonde AFM par une modélisation électrostatique des phénomènes physiques en jeu. Un des verrous à lever dans ces travaux est la disparité d'échelle des objets modélisés et le caractère tridimensionnel du système. Dans cet objectif, un modèle mathématique pour l'étude des interactions électrostatiques entre une pointe AFM et la surface d'un matériau diélectrique a été développé en 2D. La discrétisation des équations décrivant le système est basé sur un nouveau schéma numérique du type volumes finis d'ordre élevé obtenu par le principe de la reconstruction polynômiale. Ce premier modèle a permis de comprendre l'influence de la géométrie de la pointe, notamment le rayon de courbure de l'apex et l'angle de demi-ouverture, sur l'aspect qualitatif et quantitatif des courbes de force. Les résultats montrent, par exemple, que plus le rayon de courbure de la pointe est faible plus la courbure de la courbe de force est prononcée. Ces résultats sont conformes à l'expérience. Pour parfaire notre étude sur la géométrie de la pointe, un premier modèle en 3D a été développé à l'aide du logiciel commercial Comsol Multiphysics(r). Plusieurs formes de pointe ont été testées : conique, tétraèdre et pyramidale. Les courbes de forces obtenues par simulation ont été comparées aux données expérimentales permettant ainsi de trouver une forme optimale représentative de la pointe réelle. Un deuxième modèle en 3D basé sur les équations électromécaniques a été développé pour prendre en compte l'effet du bras de levier sur les courbes de force. Les résultats obtenus montrent que le bras de levier ne modifie pas la forme de la courbe de force obtenue par la pointe seule mais rajoute simplement une composante continue sur celle-ci. / The Scanning Probe Microscopy techniques (SPM) are highly diversified and no longer confined to expert laboratories, being widely used by material scientists for "micro" or "nano" applications. The use of Atomic Force Microscopy (AFM), and techniques derived from it, such as Electrostatic Force Microscopy (EFM) or Kelvin Force Microscopy (KFM), provides a considerable advantage allowing the acquisition of new information down to nanoscale, such as the charge state of dielectric materials and their ability to store and dissipate charges. However, these techniques do not allow to precisely know the spatial distribution of the lateral and deep distribution of the space charge in the insulating materials, required for a better understanding of the phenomena of transportation and charge trapping data. For this purpose, we are interested in the electrostatic force distance curve -EFDC- as a new tool to allow the location of the space charge. The aim of the thesis is to understand the relationship between the shape of the force curve and the spatial positioning of the space charge in the material. To do this, two studies were conducted in parallel: an experimental study and a study by numerical modeling. The research work here is focused mainly on the simulation of the AFM probe by electrostatic modeling of physical phenomena. One of the difficult obstacles to do in this work is the taken in account disparity of scale objects modeled and the three-dimensionality of the system. For this purpose, a mathematical model for the study of electrostatic interactions between an AFM tip and the surface of a dielectric material has been developed in 2D. The discretization of equations describing the system is based on a new numerical scheme of high order finite volume method obtained by the principle of polynomial reconstruction operator. This first model was used to understand the influence of the geometry of the tip, including the radius of curvature of the apex and the half-opening angle on the qualitative and quantitative aspects of the force curves. The results show, for example, more than the radius of curvature of the tip is smaller the curvature of the force curve is pronounced.
215

Efeitos das correlações inter-átomos adsorvidos na densidade de estados do grafeno / Effect of inter-adatoms correlations on the local density of states of graphene

Guessi, Luiz Henrique Bugatti [UNESP] 18 February 2016 (has links)
Submitted by LUIZ HENRIQUE BUGATTI GUESSI null (lhbguessi@gmail.com) on 2016-03-05T22:01:32Z No. of bitstreams: 1 Dissertação_Final_full_Luiz_Henrique_Guessi.pdf: 8393900 bytes, checksum: 733e3b310e036a5d66ec11c8c11f985e (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-03-07T18:18:44Z (GMT) No. of bitstreams: 1 guessi_lhb_me_rcla.pdf: 8393900 bytes, checksum: 733e3b310e036a5d66ec11c8c11f985e (MD5) / Made available in DSpace on 2016-03-07T18:18:44Z (GMT). No. of bitstreams: 1 guessi_lhb_me_rcla.pdf: 8393900 bytes, checksum: 733e3b310e036a5d66ec11c8c11f985e (MD5) Previous issue date: 2016-02-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Foi discutido teoricamente a Densidade Local de Estados (LDOS) de uma folha de grafeno hospedando duas impurezas distantes localizadas no centro da célula hexagonal. Ao acoplar lateralmente a ponta do Microcópio de Varredura por Tunelamento (STM) sobre o átomo de carbono, dois novos notáveis efeitos foram detectados: i) uma estrutura de multiníveis na LDOS e ii) padrões de batimentos na LDOS induzida. Também foram mostrados que ambos os fenômenos ocorrem próximos aos pontos de Dirac e são altamente anisotrópicos. Além disso, foram propostos experimentos de condutância empregando o STM como uma sonda para a observação de tais manifestações exóticas na LDOS do grafeno induzida pela correlação entre as impurezas. / We discuss theoretically the Local Density of States (LDOS) of a graphene sheet hosting two distant adatoms located at the center of the hexagonal cells. By putting laterally a Scanning Tunneling Microscope (STM) tip over a carbon atom, two remarkable novel effects can be detected: i) a multilevel structure in the LDOS and ii) beating patterns in the induced LDOS. We show that both phenomena occur nearby the Dirac points and are highly anisotropic. Furthermore, we propose conductance experiments employing STM as a probe for the observation of such exotic manifestations in the LDOS of graphene induced by inter-adatoms correlations.
216

Efeito da variação do pH em modelo de ciclagem nas propriedades de materiais restauradores

Silva, Kélio Garcia [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T19:35:57Z : No. of bitstreams: 1 silva_kg_me_araca.pdf: 3519498 bytes, checksum: 8be3bbadc0092628ca71b9618deb19ae (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / Bisco Inc., Il, Usa / O objetivo deste estudo foi avaliar o efeito da variação do pH da solução desmineralizante em modelo de ciclagem de pH na dureza de superfície, liberação de flúor e característica de superfície dos materiais restauradores: Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom e Fluorofil. Foram confeccionados, para cada material, 34 corpos-de-prova que tiveram a dureza de superfície inicial (DSI) determinada após a confecção. A seguir, foram divididos em 5 grupos (n=30) de acordo com a variação de pH (4,3; 4,6; 5,0; 5,5 e 6,2) da solução desmineralizante e submetidos a períodos cíclicos em solução desmineralizante (Des-6 horas) e remineralizante (Re-18 horas) por 15 dias. Decorrido este período, verificou-se a dureza de superfície final (DSF) e a característica de superfície (n=24). As soluções armazenadas diariamente foram utilizadas para a determinação da concentração de flúor (Des+Re). As variáveis DSI, DSF e alteração de dureza de superfície (% ADS) foram submetidas à análise de variância e a liberação de flúor ao teste de Kruskal-Wallis (p<0,05). A variação do pH proporcionou relação direta quando se comparou a dureza e inversa para a liberação de flúor nos cimentos de ionômero de vidro. Para as resinas compostas modificadas por poliácidos foi verificada relação inversa para a liberação de flúor, não havendo correlação na dureza. A característica de superfície foi influenciada pela variação do pH, ficando mais evidente nos menores pHs, exceto para as resinas compostas modificadas por poliácidos. Baseados nos resultados, concluiu-se que a variação do pH da solução desmineralizante do modelo de ciclagem influenciou a liberação de flúor dos materiais testados. Essa variação alterou a dureza e a característica de superfície dos cimentos de ionômero de vidro, mas não das resinas compostas modificadas por poliácidos. / The aim of this study was to evaluate the effect of pH of the demineralizing solution in a cycling model on surface hardness, fluoride release and surface aspects of restorative materials (Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom and Fluorofil). Thirty-four specimens of each material were made and surface hardness was measured. Then, the specimens were randomized in five groups (n=30), according to pH (4.3; 4.6; 5.0; 5.5; and 6.2) of the demineralizing solution and submitted to a cycling model during 15 days. The specimens remained in the demineralizing solution for 6 hours and in the remineralizing solution for 18 hours. After that, surface hardness was measured again and surface aspects were observed (n=24). Fluoride concentration was determined daily in all solutions (De+Re). Data from SMH (before and after pH-cycling) and %SMHC were analyzed by analysis of variance (p<0.05); Kruskal-Wallis test was carried out for the results of fluoride release. For glass ionomer cements, the variation of pH led to a direct relationship when hardness was compared and to an inverse relationship with regards to fluoride release. For polyacid-modified resin composites, an inverse relationship was found regarding fluoride release; no correlation was observed with regards to hardness. Surface aspect was influenced by pH variation: an acidic pH led to a greater alteration, except for polyacid-modified resin composites. It was possible to conclude that pH of the demineralizing solution did influence fluoride release from the tested materials. The pH variation altered hardness and surface aspects of glass ionomer cements, but it did not influence polyacid-modified resin composites in those analysis.
217

Avaliação das alterações morfológicas de três tipos diferentes de instrumentos endodônticos, após a instrumentação de canais radiculares, com a utilização da microscopia eletrônica de varredura

Somenzari Neto, Henrique [UNESP] 03 March 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-03-03Bitstream added on 2014-06-13T19:11:08Z : No. of bitstreams: 1 somenzarineto_h_me_arafo.pdf: 770431 bytes, checksum: ccfcddbbe84f78661018f873cf984b0d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Foi realizada uma análise comparativa entre três técnicas de instrumentação distintas, utilizando-se instrumentos do sistema Endo-Eze, com movimentação oscilatória; instrumentos do sistema Pow-R, com movimentação rotatória e instrumentos Tipo K manuais, com técnica de forças balanceadas. Os instrumentos foram utilizados em uma sequência técnica pré-determinada em pré-molares superiores humanos, birradiculados, por cinco vezes. Para cada técnica utilizamos quatro jogos de instrumentos novos. Os instrumentos foram fotografados com o auxílio do microscópio eletrônico de varredura quando estavam sem uso, após uma vez de uso e após cinco vezes de uso. Para cada instrumento utilizado foi atribuído um escore de acordo com o grau de deformação apresentado. A correlação numérica para cada instrumento foi submetida a uma análise estatística (Teste de Kruskal-Wallis) para podermos determinar diferenças estatísticas significantes entre esses três grupos de instrumentos endodônticos. Os resultados obtidos foram tratados estatísticamente e permitiram concluir que não houve diferenças estatisticamente significantes entre os três grupos estudados para a situação de uma vez de uso. No entanto, para as situações sem uso e cinco vezes de uso os instrumentos do Grupo I (Endo-Eze) apresentaram melhores resultados quando comparados com os Grupos II e III (Pow-R e Manual). / It was comparatively analysed 3 different instrumentation techniques upon Endo-Eze, Pow-R and manual K-file instrument deformation Upper bicuspid teeth were instrumented 5 times, and the instruments were photographed before, and after 1 and 5 times of use. For each instrument, it was stablished one specific score, that when submmited to Kruskal-Wallis test showed better results to Endo-Eze group, followed by Pow-R and Manual respectivelly.
218

Caracterização nanoestrutural de filmes finos do grupo IV-B depositados por sputtering magnetron / Nanostructural characterization of Group IV thin films deposited by magnetron sputtering

Eliane de Fátima Chinaglia 11 November 2002 (has links)
Correlações do tipo processo-estrutura-propriedade de filmes têm sido objeto de extensos estudos já a várias décadas, tanto do ponto de vista científico como tecnológico. Mais recentemente, atenção crescente tem sido dada a filmes cada vez mais finos, principalmente para atender as necessidades de novas tecnologias. Para compreender melhor a correlação processo-estrutura, vários pesquisadores propuseram Modelos de Zonas Estruturais para filmes com espessuras, tipicamente, de algumas unidades a dezenas de micrometros. Neste trabalho, propomos Modelos de Zonas Estruturais para filmes finos de elementos do Grupo IV-B (Ti, Zr e Hf) e estudamos os mecanismos de formação da microestrutura dos filmes. Durante o desenvolvimento de nosso trabalho, curiosos aglomerados de grãos, com tamanhos de vários micrometros e com geometria fractal, foram observados nos filmes de Zr. As características geométricas dos aglomerados e os possíveis mecanismos que os originam e levam à sua evolução também são considerados aqui. / Correlations type processing-structure-property of films have been the subject of extensive studies for the last several decades, both from the point of view of science and technology. More recently, growing attention has been given to ever-thinner films, especially to satisfy the needs of newer technologies. To better understand the correlation processing-structure, many researchers have proposed Structure Zone Models for films typically a few to a few tens of micrometers thick. In this work, we propose Structure Zone Models for Group IV-B (Ti, Zr and Hf) thin films and study the microstructure forming mechanisms of the films. During the development of our work, intriguing grain aggregates several micrometers Jorge and with fractal geometry were observed in the Zr films. The geometrical characteristics of the aggregates, their possible origin and evolution mechanisms are also considered here.
219

Desenvolvimento e caracterização de um microscópio óptico holográfico sem lentes in-line / Development and characterization of an in-line lensless holographic optical microscope

Camila de Paula D\'Almeida 31 July 2018 (has links)
O microscópio é um instrumento de grande relevância para o contexto científico. Dentre as variadas montagens desse instrumento óptico, os microscópios sem lentes têm chamado atenção por serem robustos, reduzidos em tamanho e custo, e ainda possibilitarem imagens com amplo campo de visão (usualmente da ordem de algumas dezenas de mm2). Dentro dessa categoria, existem os microscópios holográficos in-line, os quais obtêm a imagem da amostra a partir da reconstrução numérica de um holograma adquirido por um sensor digital de imagem. Este trabalho tem o objetivo de construir um desses microscópios para observar amostras semitransparentes. O microscópio desenvolvido ao longo deste trabalho tem sua iluminação baseada no uso de um LED associado a um pinhole, cuja finalidade é aumentar a coerência temporal da luz. Com isso, a iluminação proveniente do pinhole percorre uma distância de aproximadamente 10 cm até atingir a amostra, posicionada sobre uma lâmina de vidro. À uma distância mínima da amostra, está posicionado um sensor CMOS, responsável pela aquisição do padrão de interferência da parcela da luz que foi transmitida sem desvio pela amostra e da parte da luz que foi difratada por ela. Esse padrão de intensidade, chamado holograma, é reconstruído numericamente de modo a obter uma boa imagem do objeto-alvo. A reconstrução da imagem medida é feita considerando a propagação da luz de volta ao plano de do objeto e, depois, estimando a fase referente à luz incidente no sensor no instante da medida. Essa primeira etapa resulta na imagem da amostra com a influência de um artefato muito conhecido na holografia: a imagem gêmea. Enquanto a reconstrução de fase reconstrói a imagem de uma forma mais completa, reduzindo a influência de tais artefatos. A reconstrução de fase é feita com o método multialturas, o qual faz uso de mais de uma imagem medida, com distâncias diferentes entre a amostra e o sensor, como entrada para o algoritmo desenvolvido. Utilizando um sensor de 10 MP (3856 x 2764 pixels), com o pixel de 1,67 &mu;m, construímos um microscópio holográfico sem lentes com um campo de visão de quase 30 mm2 e resolução de aproximadamente 3 &mu;m. / The microscope is an instrument of great relevance in the scientific context. Among various assembly of this optic instrument, the lensless microscope have had drawing attention by been robust, with small size and low cost and, in addiction, enable imaging with a large field of view (usually about tens of mm2). Inside this category, there is the in-line holographic microscopes, which achieve the sample image from the numerical reconstruction of a hologram acquired by an image digital sensor. This study have the objective of develop one of these microscopes to image semitransparent samples. The microscope developed over this study has its illumination based on the use of an LED associated with a pinhole, whose purpose is to increase the light temporal coherence. Therefore, illumination from the pinhole goes 10 cm until reach the sample, positioned over the glass slide. From a minimal distance of the sample, a CMOS sensor is positioned, which is responsible to acquire the interference pattern of the transmitted light with the diffracted light. This intensity pattern, called hologram, is numerically reconstructed in order to get a great image of target object. The reconstruction of the measured image is performed considering the back propagation of the light to the object plane and, then, estimating the phase related to the incident light over the sensor at the time of the measurement. This first step results in a sample image influenced by an artifact well-known in the holography: the twin-image. Whereas phase reconstruction reconstruct the image more fully, reducing the artifact influence. Phase reconstruction is performed using the multiheigh method, which uses more than one measured image, with different distances between the sample and sensor, as input to the developed algorithm. Using a 10 MP (3856 x 2764 pixels) sensor, with a pixel size of 1.67 &mu;m, we built a lensless holographic microscope with a field of view near of 30 mm2 and resolution of approximately 3 &mu;m.
220

Avaliação radiográfica, biomecânica e microscópica de enxerto ósseo xenogênico associado a implantes de titânio em mandíbula de coelhos / Radiographic, biomechanical and microscopic evaluation of xenogenic bone graft associated to titanium implants in rabbits mandible

Etiene de Andrade Munhoz 08 June 2009 (has links)
O propósito deste trabalho foi avaliar a interação de matriz óssea bovina inorgânica, (Gen-ox®) como material de enxerto e implantes de titânio em mandíbula de coelhos. A amostra constituiu-se de 32 coelhos da raça Botucatu de aproximadamente 4kg. Os incisivos inferiores destes animais foram extraídos e foi realizada um defeito de aproximadamente 4mm de diâmetro. Um dos lados foi mantido apenas com coágulo (grupo controle) e o outro lado (grupo experimental) recebeu o enxerto do material proposto. Após 60 dias foram instalados implantes bilateralmente na região do defeito. Os animais foram eutanaziados imediatamente após a instalação dos implantes e após 1, 2 e 6 meses (n=6) para o grupo microscópico a após 2 e 6 meses para o grupo do teste biomecânico (n=4). A análise constituiu de medidas da distância da crista óssea alveolar à plataforma do implante, da densidade radiográfica em valores de pixel ma região do alvéolo, de teste biomecânico de torque de remoção e microscópico através de medidas de contato osso-implante (BIC) (em µm e %) e área de osso (em µm2 e %). Os resultados demonstraram que não houve diferenças significantes nem durante o tempo e nem entre os grupos na analise de distancia entre crista óssea alveolar e plataforma do implante. Na medida de densidade óssea, não houve variação significante ao longo do tempo, mas houve diferença estatisticamente significante entre os grupos, sendo maior no grupo experimental. Para o teste biomecânico também não houve variação significante do torque de remoção ao longo do tempo e nem houve diferença significante entre os grupos. Na análise de contato osso implante (BIC) não houve variação significante ao longo do tempo, mas houve diferença estatisticamente significante entre os grupos, sendo maior no grupo experimental e houve interação entre tempos e grupos. E com relação a medida de área de osso não houve diferenças significantes nem durante o tempo e nem entre os grupos controle e experimental nos períodos analisados. Os resultados sugerem que o material foi bem aceito na região e teve comportamento semelhante ao coágulo em contato com a superfície do implante. / The aim of this study was to evaluate the interaction of an inorganic bovine bone matrix (Gen-ox®) as bone graft and titanium implants in rabbits mandible. Thirty-two Botucatu rabbits weighting about 4kg were used on this experiment. The mandible incisives were extracted and a defect of 4 mm of diameter was performed. One socket and defect was filled with experimental material. The opposite site was left to heal naturally and served as control. After 60 days, the implants were installed on the defect region. The animals were killed immediately after the implant installation and after 1, 2 and 6 months. Vertical bone height, bone density, biomechanical test, bone implant contact (BIC) and bone area near to implant threads were evaluated. The results showed that there was no significant differences on the distance between the alveolar bone crest to the implant platform (vertical bone height) along the time, neither between groups. On the bone density (pixel value) there was no significant difference along the time, but there was significant difference between groups, being the experimental group higher. For the biomechanical test there was no significant difference along the time, neither between groups. There was no significant differences on the bone implant contact (BIC) measures along the time, but there was significant difference between groups, being the experimental groups higher and there was interaction between time and groups. On bone area evaluation, there was no significant difference along the time, neither between the groups during the analyzed time. The graft behavior observed by the authors was similar to that of the control group, suggesting high acceptance of the material as graft option associated to titanium implants.

Page generated in 0.056 seconds