61 |
Implementação de um sistema de eletrodos microfabricados para registro e estimulação neural extracelular in vitroVidor, Carolina de Barros January 2014 (has links)
Made available in DSpace on 2014-07-23T02:01:34Z (GMT). No. of bitstreams: 1
000459620-Texto+Completo-0.pdf: 5079443 bytes, checksum: 08c93370bfca9d36a99775d85a58b7d2 (MD5)
Previous issue date: 2014 / The main goal of this work was to implement a microfabricated electrode system for in vitro neural stimulation and recording. The MEA biosensor structural characterization was obtained by optical and scanning electrical microscopy images. Qualitative analysis of the chemical composition was made through energy-dispersive X-ray spectroscopy. Analysis of the noise level was conducted by evaluating the RMS value of the potentials recorded with sensors filled with standard saline solution. An electronic interface between a MEA and a conventional data acquisition system with eight channels was constructed and performance tests of the built interface were conducted. Installation of a MEA commercial system was carried out and preliminary tests were performed by experimenting with rodent neuronal cell culture and brain slices. An attempt was made to adapt a conventional perfusion system by peristaltic pump to the MEA system; however, the results were unsatisfactory due to the high noise level of the recordings. Experimental procedures related to the proper handling of MEAs were defined, and the influence of different parameters involved in experimentation with MEAs was investigated. Finally, the data analysis of cell culture recordings indicated detection of local field potentials (LFPs) of greater amplitude, higher counts of spikes and higher spike frequency in the records obtained with standard culture medium compared to those obtained with extracellular electrophysiological solution. The data analysis of cortical slices recordings indicated the detection of a greater number of spikes per minute, higher spike frequency and greater peak-to-peak spikes amplitudes by the microelectrodes that have captured LFPs of greater magnitude. / O objetivo principal deste trabalho foi implementar um sistema de eletrodos microfabricados para registro e estimulação neural extracelular in vitro. A estrutura dos arranjos de microeletrodos (MEAs) foi caracterizada através de imagens por microscopia óptica e por microscopia eletrônica de varredura. A análise qualitativa da composição química foi feita por espectroscopia de raios X por energia dispersiva e a análise do nível de ruído foi realizada através da avaliação do valor RMS dos potenciais registrados com os sensores preenchidos com solução salina padrão. Uma interface eletrônica entre um MEA e um sistema de aquisição de dados convencional com oito canais foi construída e testes de desempenho foram realizados. Um sistema MEA comercial foi instalado e validado através de experimentação com cultura neuronal e fatias de cérebro de roedor. A tentativa de adaptação de um sistema convencional de perfusão por bomba peristáltica ao sistema MEA mostrou-se insatisfatória devido ao alto nível de ruído dos registros. Procedimentos experimentais relacionados ao correto manuseio dos MEAs foram definidos, e investigou-se a influência de diferentes parâmetros sobre a atividade detectada com os sensores. Finalmente, a análise dos dados com cultura celular indicou detecção de potenciais de campo locais (PCLs) de maior amplitude, maior contagem de spikes e maior freqüência de atividade nos registros obtidos com meio de cultura padrão. Os dados com fatias de tecido indicaram a detecção de maior número de spikes por minuto, de maior freqüência de atividade e de maior amplitude pico-a-pico dos spikes nos microeletrodos que captaram PCLs de maior amplitude.
|
62 |
Anodização de ligas de aluminio por corrente pulsadaRegone, Natal Nerimio 03 August 2018 (has links)
Orientador: Celia Marina Alvarenga Freire / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-03T21:12:04Z (GMT). No. of bitstreams: 1
Regone_NatalNerimio_D.pdf: 7846072 bytes, checksum: 7b9d73211e61fea4842f739fc2d0df32 (MD5)
Previous issue date: 2004 / Doutorado
|
63 |
Avaliação da resposta tecidual frente a diferentes materiais de fixação em enxertos ósseos autógenos: análise microscópica morfológica / Evaluation of tissue response due to different fixation materials in autogenous bone grafts: microscopic morphological analysisMatsumoto, Mariza Akemi 15 May 2003 (has links)
Os enxertos ósseos autógenos têm sido largamente empregados para a reconstrução de rebordos atróficos. A fixação destes enxertos é fundamental no fenômeno de reparação óssea, propiciando a incorporação ao leito receptor e rápida revascularização. Placas e parafusos sintéticos reabsorvíveis têm sido desenvolvidos na tentativa de minimizar alguns pontos negativos dos materiais metálicos rotineiramente utilizados para esta finalidade. O presente estudo avaliou comparativamente as condições ósseas locais de enxertos ósseos autógenos oriundos da região mentoniana quando em contato com parafusos de ácido poliglicólico (PGA)/ácido poli (L-láctico) (PLA) e de titânio. Para esta avaliação, participaram sete pacientes apresentando atrofias maxilar e mandibular severas, impossibilitando a reabilitação com implantes osteointegráveis. Após quatro meses das cirurgias de enxerto, as áreas onde se localizavam os parafusos de teste foram biopsiadas com brocas trefinas, obtendo-se os espécimes a serem submetidos a procedimento histotécnico de rotina e corados em H.E. e Tricrômico de Mallory para avaliação morfológica em microscopia óptica de luz. A partir desta análise observouse, adjacente aos parafusos de titânio, tecido ósseo viável, com eventuais áreas recobertas por células de revestimento e ausência de reabsorção. Adjacente aos parafusos reabsorvíveis, o tecido ósseo também apresentou viabilidade morfológica, porém, com presença de extensa faixa de tecido conjuntivo fibroso interposto, e eventuais células gigantes. Estes resultados sugerem que ambos os métodos de fixação proporcionaram condição de reparo no local de enxertos, contudo, os parafusos reabsorvíveis induziram reação inflamatória mais extensa que os de titânio, caracterizada por reação tipo corpo estranho. / Autogenous bone grafts have been largely used for the reconstruction of severely atrophic ridges. The fixation of these grafts plays an important role in bone graft repair, leading to the integration to the receptor bed and early revascularization. Resorbable plates and screws are being developed in an attempt to minimize some negative aspects of the metallic devices routinely used in this procedure. The present work evaluated comparatively local bone conditions of autogenous grafts retrieved from the chin, in contact with polyglicolic / poly (L-lactic) acid and titanium screws. Seven patients presenting severe maxillary atrophy, unabling rehabilitation with endosseous implants, participated in this study. After four months of the grafting, the regions containing the test screws were biopsied using trephine bur, the specimens retrieved undergone histological routine procedures, and stained with HE and Mallory Trichromic to be morphologically evaluated under light microscopy. From this analysis, viable bone tissue was noted around the titanium screws, eventually presenting lining cells with no signs of resorption. Around the resorbable screws, viable bone tissue was also observed, although, presenting a thick layer of connective tissue interposed between the screw and the bone, and eventual foreign body giant cells. These results suggest that both fixation method provided good condition of local repair, however, the resorbable screws induced a longer inflammatory phase than the titanium screws, characterized by foreign body reaction.
|
64 |
Estudo Metodológico de Avaliação do Crescimento Ósseo ao Redor de Implantes Osseointegrados Através de Microscopia Confocal de Varredura a Laser e Torque de Remoção.Lourenço Júnior, Evandro de Toledo 20 August 1999 (has links)
A necessidade de uma compreensão cada vez abrangente sobre o fenômeno da osseointegração faz com que os pesquisadores busquem melhorias constantes nos meios de avaliação deste processo cicatricial. Para analisar as características deste fenômeno ao redor de implantes NAPIO inseridos em tíbias de coelhos, foi realizado um duploo acompanhamento pós-operatório (forças de torque e histológico). Sete animais foram usados neste experimento e cada um recebeu a colocação de 2 implantes, um para avaliação histológica e outro para obtençào da força de remoção por torque. Os animais receberam injeções intra-musculares de 3 diferentes marcadores da atividade óssea, tetraciclina, alizarina e calceína em diferentes intervalos de tempo: Dia 0 14 implantes em 7 animais; Dia 7 Tetraciclina em 6 animais Dia 15 - Sacrifício animais 1 e 2 e Alizarina animais 3, 4, 5 e 6; Dia 21 - Alizarina animais 3, 4 5 e 6; Dia 45 - Sacrifício animais 3 e 4 e Calceína animais 5 e 6; Dia 52 - Calceína animais 5 e 6; Dia 90 - Sacrifício animais 5 e 6; Dia 180 - Sacrifício animal 7 (sem marcador); No momento do sacrifício dos animais os implantes para torque foram removidos e os valores obtidos foram registrados: Animal 1 - 7,49 N.cm (15 dias após a inserção); Animal 2 7,12 N.cm (15 dias após a inserção) èMédia=7,30 N.cm; Animal 3 35,4 N.cm (45 dias após a inserção); Animal 4 31,1 N.cm (45 dias após a inserção) èMédia=35,25 N.cm; Animal 5 58,1 N.cm (90 dias após a inserção); Animal 6 47,2 N.cm (90 dias após a inserção) èMédia=52,65 N.cm; Animal 7 79,7 N.cm (180 dias após a inserção); Os implantes para avaliação histológica foram processados pela técnica de Donath e analisados por microscopia confocal a laser, sendo detectada intensa atividade óssea na interface implante/osso. Os resultados demonstraram uma contínua formação óssea circunjacente aos implantes e concomitantemente um aumento da força de remoção por torque à medida que o intervalo de tempo pósinserção aumentou. / Trying to understand osseointegration, many researches look for better means to evaluate this healing process. In order to analysis this healing process around NAPIO implants is rabbits tibia, a double follow-up was done (torque removal forces and histology). Seven animals were used in this study and each one received 2 implants (one for confocal scanning laser microscopy analysis and the other to obtain the removal torque). The animals received 3 bone labelers injections of Tetracicline, Alizarine and Calceine on different intervals. Day 0 - 14 implants on 7 animals Day 7 - Tetracicline on 6 animals (1, 2, 3, 4, 5 and 6); Day 15 - Sacrifice animals 1 and 2, and Alizarine animais 3, 4, 5 and 6; Day 21 - Alizarine on animals 3, 4, 5 and 6; Day 45 - Sacrifice animals 3 and 4; Calceine animals 5 and 6; Day 52 - Calceine on animais 5 and 6; Day 90 - Sacrifice animals 5 and 6; Day 180 - Sacrifice animals 7 (no bone labeler); At the sacrifice moment the torque removal implants were registered: Animal 1 - 7,49 Ncm; Animal 2 7,12 Ncm èMean=7,30 Ncm; Animal 3 35,4 Ncm; Animal 4 31,1 Ncm è Mean =35,25 Ncm Animal 5 58,1 Ncm; Animal 6 47,2 Ncm è Mean =52,65 Ncm; Animal 7 79,7 Ncm; The remaining implants undergone histologic preparation by Donath technique and were submetted to confocal scanning laser microscopy. This analysis demonstrated a great bone activity on bone/implant interface. The results showed a continuous bone formation around implants and na increasing torque removal force at different time intervals.
|
65 |
Microscopia eletrônica de estruturas de superfície em cristais de diamantes do Brasil / Not available.Svizzero, Darcy Pedro 02 April 1969 (has links)
Não disponível. / Not available.
|
66 |
Morfologia da junção amelocementária em dentes decíduos humanos na microscopia eletrônica de varredura e os efeitos da clareação externa / Morphology of the cementoenamel junction (CEJ) of deciduous human teeth on scanning electron microscopy (SEM) and the effects of external bleachingFrancischone, Leda Aparecida 05 May 2006 (has links)
A valorização da estética não ocorre apenas no indivíduo adulto, mas também na criança. A clareação dentária externa realizada é uma alternativa viável e segura de tratamento estético desde que realizada pelo profissional e respeitados requisitos importantes como proteger os dentes e tecidos moles para que os riscos sejam os menores possíveis. Por ser o ponto frágil da estrutura dentária o conhecimento sobre a morfologia da junção amelocementária é muito importante durante alguns procedimentos clínicos e especialmente na clareação dentária. O objetivo deste estudo foi analisar os tipos morfológicos de inter-relação tecidual na região cervical dos dentes decíduos e compará-los nos diferentes grupos dentários, além de avaliar as alterações morfológicas da junção amelocementária induzidas pela clareação dentária externa a laser. Com esses objetivos, analisou-se a junção amelocementária de 120 dentes decíduos à microscopia eletrônica de varredura. Destes, 105 eram não clareados e subdivididos em grupos de 15 espécimes por grupo dentário e outros 15 foram clareados. Ao término das análises estabeleceram-se os padrões morfológicos da junção amelocementária decídua e compararam-se com os encontrados nos dentes clareados. Os três tipos de relação entre tecidos mineralizados na junção amelocementária foram cemento recobrindo esmalte, esmalte e cemento topo-a-topo e a presença de \"gap\" entre o esmalte e o cemento, expondo áreas de dentina, não detectando-se qualquer predominância quanto aos grupos dentários. Em todos os dentes, apresentaram-se os três tipos morfológicos de junção amelocementária. O uso da técnica de clareação externa tendo-se o laser como ativador acentuou o contorno do esmalte e do cemento deixando-os mais nítidos e os túbulos dentinários nos \"gaps\" se apresentaram mais abertos e em maior número, indicando uma ampliação na área dos \"gaps\". Por apresentar forma irregular e presença de \"gaps\", a junção amelocementária decídua pode ser uma região mais frágil para a instalação de reabsorções cervicais externas em casos de traumatismos e colocação inadequada de grampos para isolamento absoluto. A expansão dos \"gaps\" pelos agentes clareadores pode estar associada a uma maior sensibilidade dentinária após a clareação dentária externa tal como foi descrita em dentes permanentes. / Esthetics is not only important for adults but also for children. External dental bleaching is a feasible and safe alternative of esthetic treatment, as long as performed by the professional under some important required conditions, such as, adequate protection of the teeth and soft tissues, so that risks are as reduced as possible. Since the cementoenamel junction (CEJ) is the fragile spot of the dental structure, previous knowledge of its morphology is essential in order to perform certain clinical procedures and especially dental bleaching. The goal of this study was to analyze the morphological types of intertissues relation on the cervical area of deciduous teeth, comparing them between different dental groups and evaluating the morphological alterations of the cementoenamel junction (CEJ) induced by dental external laser bleaching. The sample comprised 120 deciduous teeth analyzed by scanning electron microscopy (SEM). Out of the 120 deciduous teeth, 105 remained unbleached and were divided in groups of 15 specimens for each dental group. The last 15 teeth were submitted to laser bleaching. The analysis performed allowed us to establish the morphological patterns of the cementoenamel junction (CEJ) in deciduous teeth with and without bleaching. The three types of interrelations between the mineralized tissues at the cementoenamel junction (CEJ) were: enamel overlapped by cementum; enamel and cementum edge-to-edge; and a gap, revealing a strip of exposed dentin. No predominance of any of the three types of interrelations between groups was found, whatsoever. All groups of teeth presented the three morphological types of cementoenamel junction (CEJ). The technique of external bleaching activated by laser enhanced the outline of the enamel and cementum making them more noticeable. The dentin tubule at the areas of gap were widened and more numerous indicating amplification of the gap areas after bleaching. Since the cementoenamel junction (CEJ) of deciduous teeth also presents irregularities and gaps, it may be a more fragile and susceptible area to the occurrence of cervical external root resorption in case of traumatisms or due to the inadequate installation of rubber dam clips. The expansion of the gaps by bleaching agents may be associated with increased dentinal sensitivity after external dental whitening, such as described in permanent teeth.
|
67 |
Estudo Metodológico de Avaliação do Crescimento Ósseo ao Redor de Implantes Osseointegrados Através de Microscopia Confocal de Varredura a Laser e Torque de Remoção.Evandro de Toledo Lourenço Júnior 20 August 1999 (has links)
A necessidade de uma compreensão cada vez abrangente sobre o fenômeno da osseointegração faz com que os pesquisadores busquem melhorias constantes nos meios de avaliação deste processo cicatricial. Para analisar as características deste fenômeno ao redor de implantes NAPIO inseridos em tíbias de coelhos, foi realizado um duploo acompanhamento pós-operatório (forças de torque e histológico). Sete animais foram usados neste experimento e cada um recebeu a colocação de 2 implantes, um para avaliação histológica e outro para obtençào da força de remoção por torque. Os animais receberam injeções intra-musculares de 3 diferentes marcadores da atividade óssea, tetraciclina, alizarina e calceína em diferentes intervalos de tempo: Dia 0 14 implantes em 7 animais; Dia 7 Tetraciclina em 6 animais Dia 15 - Sacrifício animais 1 e 2 e Alizarina animais 3, 4, 5 e 6; Dia 21 - Alizarina animais 3, 4 5 e 6; Dia 45 - Sacrifício animais 3 e 4 e Calceína animais 5 e 6; Dia 52 - Calceína animais 5 e 6; Dia 90 - Sacrifício animais 5 e 6; Dia 180 - Sacrifício animal 7 (sem marcador); No momento do sacrifício dos animais os implantes para torque foram removidos e os valores obtidos foram registrados: Animal 1 - 7,49 N.cm (15 dias após a inserção); Animal 2 7,12 N.cm (15 dias após a inserção) èMédia=7,30 N.cm; Animal 3 35,4 N.cm (45 dias após a inserção); Animal 4 31,1 N.cm (45 dias após a inserção) èMédia=35,25 N.cm; Animal 5 58,1 N.cm (90 dias após a inserção); Animal 6 47,2 N.cm (90 dias após a inserção) èMédia=52,65 N.cm; Animal 7 79,7 N.cm (180 dias após a inserção); Os implantes para avaliação histológica foram processados pela técnica de Donath e analisados por microscopia confocal a laser, sendo detectada intensa atividade óssea na interface implante/osso. Os resultados demonstraram uma contínua formação óssea circunjacente aos implantes e concomitantemente um aumento da força de remoção por torque à medida que o intervalo de tempo pósinserção aumentou. / Trying to understand osseointegration, many researches look for better means to evaluate this healing process. In order to analysis this healing process around NAPIO implants is rabbits tibia, a double follow-up was done (torque removal forces and histology). Seven animals were used in this study and each one received 2 implants (one for confocal scanning laser microscopy analysis and the other to obtain the removal torque). The animals received 3 bone labelers injections of Tetracicline, Alizarine and Calceine on different intervals. Day 0 - 14 implants on 7 animals Day 7 - Tetracicline on 6 animals (1, 2, 3, 4, 5 and 6); Day 15 - Sacrifice animals 1 and 2, and Alizarine animais 3, 4, 5 and 6; Day 21 - Alizarine on animals 3, 4, 5 and 6; Day 45 - Sacrifice animals 3 and 4; Calceine animals 5 and 6; Day 52 - Calceine on animais 5 and 6; Day 90 - Sacrifice animals 5 and 6; Day 180 - Sacrifice animals 7 (no bone labeler); At the sacrifice moment the torque removal implants were registered: Animal 1 - 7,49 Ncm; Animal 2 7,12 Ncm èMean=7,30 Ncm; Animal 3 35,4 Ncm; Animal 4 31,1 Ncm è Mean =35,25 Ncm Animal 5 58,1 Ncm; Animal 6 47,2 Ncm è Mean =52,65 Ncm; Animal 7 79,7 Ncm; The remaining implants undergone histologic preparation by Donath technique and were submetted to confocal scanning laser microscopy. This analysis demonstrated a great bone activity on bone/implant interface. The results showed a continuous bone formation around implants and na increasing torque removal force at different time intervals.
|
68 |
Espalhamento de raios X a baixo angulo : estudo de hemoglobinas extracelulares em soluçãoSouza, Christina Franco de 22 July 1990 (has links)
Orientador: Iris Concepcion Linares de Torriani / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-09-27T18:33:13Z (GMT). No. of bitstreams: 1
Souza_ChristinaFrancode_D.pdf: 4793967 bytes, checksum: 74b68cad0c27d2b7d2b2fb027fe59ab2 (MD5)
Previous issue date: 1990 / Resumo: A técnica de espalhamento de raios X a baixo ângulo tem sido bastante utilizada nos últimos anos no estudo de proteínas em solução. Curvas de espalhamento de alta resolução, além de fornecerem parâmetros dimensionais, possibilitam a obtenção de informações sobre a estrutura quaternária de macromoléculas através de simulações com modelos. Neste trabalho, estudamos a eritrocruorina do anelídeo Glossoscolex paulistus (massa molecular de 3.23x106). Curvas de espalhamento a baixo ângulo de várias concentrações da proteína em solução foram obtidas com um gerador convencional de raios X. A partir destes dados foi possível determinar os valores de raio de giro e dimensão máxima na molécula por gráficos de Guinier e transformada indireta de Fourier. Obtivemos, também, curvas de alta resolução no síncrotron do LURE, Orsay, França. As intensidades espalhadas. por apresentarem uma série de máximos nos ângulos maiores, pareceram apropriadas ao cálculo de modelos. Para tal usamos um programa de computador desenvolvido por O. Glatter [7]. O modelo inicial, composto de 186 esferas idênticas, foi estruturado com base em informações disponíveis de microscopia eletrônica. Modificações sistemáticas deste modelo levaram a uma estrutura final que consiste de 12 subunidades principais arranjadas em duas camadas hexagonais sobrepostas formando um cilindro com uma subunidade adicional no centro. Durante o processo de ajuste do modelo, diferentes pesos foram atribuídos às esferas que compunham as subunidades principais. 0 modelo final simula bem as curvas experimentais e contém informação sobre as regiões de maior densidade eletrônica na molécula, sugerindo uma possível localização dos grupos heme / Abstract: Small angle X-ray scattering is a technique that has been widely used during the last decade for the study of proteins in solution. High resolution scattering curves, can not only provide information on the dimensional parameters of the molecules, but also lead to a description of the quaternary structure of the protein by filling the experimental intensity curves and distance distribution functions with those calculated for a model molecule. This work reports studies of erythrocruorin from the annelid species Glossoscolex paulistus (molecular weight 3,23 x 106). Small angle scattering curves from various concentrations of this protein in solution were obtained with a conventional X-ray generator. The radius of gyration and maximum dimension of the molecule were obtained from Guinier plots and inverse Fourier transform. High resolution intensity curves were obtained al the synchrotron source at LURE, Orsay, France. These curves presented a number of maxima at higher angles and seemed adequate for model calculations. These were performed using the computer program developed by O. Glatter [7]. The initial model, formed by 186 identical spheres, was built using the information available from electron microscopy. Systematic modifications of this model lead us to a final structure consisting of 12 principal subunits, arranged in two superposed hexagonal layers forming a hexagonal cylinder, with an additional subunit in its center. During the filling procedure, different weights were assigned to the spheres composing the structure. The final model reproduces the experimental scattering curves and contains information on the more electron-dense regions in the molecule, thus suggesting the possible site of the heme groups / Doutorado / Física / Doutor em Ciências
|
69 |
Estudo de Mytella falcata (Mollusca, Bivalvia) como indicadora de efeitos genotóxicos e citotóxicos no estuário de Santos, SPDavid, José Augusto de Oliveira [UNESP] 26 April 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:55Z (GMT). No. of bitstreams: 0
Previous issue date: 2007-04-26Bitstream added on 2014-06-13T19:40:28Z : No. of bitstreams: 1
david_jao_dr_rcla.pdf: 933714 bytes, checksum: 206e3f9f14e600b5847ba3020cae58f0 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O estuário de Santos já foi um exemplo de degradação ambiental, porém medidas dos órgãos responsáveis pelo saneamento ambiental resultaram em melhoria na qualidade das águas, mas os sedimentos e a biota continuam contaminados. Os moluscos bivalves são bons bioindicadores de poluição ambiental, devido a seu hábito séssil e filtrador, e à capacidade de acumular diversas substâncias. Mytella falcata é uma espécie comum em regiões tropicais, encontrada semi-enterrada no sedimento, podendo fornecer dados sobre as condições do mesmo. Neste trabalho, bivalves da espécie Mytella falcata residentes em três pontos do estuário de Santos com diferentes níveis substâncias potencialmente poluidoras, foram analisado a fim de caracterizar a população residente nestes pontos. As técnicas utilizadas foram o ensaio do cometa, o teste do micronúcleo e a análise histopatológica das brânquias, incluindo técnicas histoquímicas, ultramorfológica e ultra-estrutural. As análises demonstraram que a espécie pode ser para avaliar danos genotóxicos, mutagênicos e citotóxicos. Utilizando o ensaio do cometa os indivíduos dos pontos B e C mostraram níveis significativamente maiores de danos ao DNA quando comparados aos animais do ponto A. Quanto a análise dos micronúcleos os animais de todos os pontos apresentaram resposta muito semelhante. A morfologia dos filamentos branquiais desta espécie mostrou-se muito similares a de espécies próximas e na análise histopatológica foram observadas alterações nos pontos B e C; as principais foram o desprendimento do epitélio da região lateral do filamento, modificação na morfologia deste epitélio, aumento na produção de muco e processos envolvidos na eliminação de células e renovação das mesmas. Os dados obtidos mostraram que todas as técnicas resultaram no diagnóstico de que os animais residentes no ponto... / The Santos estuary which is located in São Paulo, Brazil, was considered one of the major examples of coastal degradation. Nowadays the quality of this environment has improved, but the sediment and the biota are still contaminated. Bivalve mollusks are sedentary, filter-feeding invertebrates that have been widely used to monitor aquatic habitats. Mytella falcata is very common in tropical areas and lives buried in the sediment. In this study, the mussel Mytella falcata, from three sites of Santos estuary, were analyzed; the three sites presented different levels of harmful substances. The aim of this analysis was to characterize the animals that live in this area. The techniques applied were the comet assay, micronucleus test and histopathological analysis of the gill filaments, including the histochemistry and scanning and transmission electron microscopy. Laboratory tests demonstrated that the species can be used as bioindicator. The analyzed specimens from sites B and C, showed higher levels of DNA damage when compared to those from site A. The micronucleus test presented no difference between the three sites. Mytella falcata gill filaments showed high similarity to other Mytilidae species. The histopathological analysis demonstrated some alterations in sites B and C. The major alterations were the detachment of epithelial cells from the lateral surface, changes in the morphology of this epithelium, increase in mucous production and processes involved in cell elimination and renovation. The damages found in animals from sites B and C were considered as adaptations to the exposition to pollutants. The lack of difference between animals from sites B and C were related with the distance between animals and sediment. In conclusion, this study confirm that sediments act as a deposition site for pollutants and alert the authorities for the manner of dealing with this sediment... (Complete abstract click eletronic access below)
|
70 |
Aplicação de microscopia eletrônica ao estudo dos sedimentos cenozoicos da província costeira do Rio Grande do Sul, Brasil / Not available.Elida Brum Krauspenhar 29 December 1977 (has links)
Não disponível. / Not available.
|
Page generated in 0.0522 seconds