Spelling suggestions: "subject:"minipig""
1 |
Carga imediata sobre implantes osseointegráveis para ancoragem ortodôntica: estudo em minipigs / Immediately loaded osseointegrated implants for orthodontic anchorage: study in minipigsNavarro, Paula Vanessa Pedron Oltramari 17 December 2008 (has links)
O objetivo deste trabalho foi avaliar a taxa de sucesso, a quantidade de perda óssea em altura e a interação osso/implante para três diferentes protocolos: 1) implantes osseointegráveis mantidos sem carga durante período de reparo de 120 dias; 2) implantes submetidos a interferências oclusais; e 3) implantes que receberam carga imediata para ancoragem ortodôntica. Foram utilizados doze minipigs BR-1, nos quais foram instalados 70 implantes osseointegráveis de titânio (3,75mm diâmetro x 8,50mm comprimento), divididos em 5 grupos: Grupo 1 (n=12), implantes sem carga sepultados na mesial de caninos; Grupo 2 (n=6), implantes sem carga em áreas de extração; Grupo 3 (n=12), implantes expostos a interferências oclusais; Grupo 4 (n=20), implantes submetidos à carga ortodôntica imediata; Grupo 5 (n=20), implantes instalados em áreas de extração e submetidos à carga ortodôntica imediata. Ao término do período experimental, os animais foram eutanasiados e biópsias da região de interesse coletadas. Realizou-se avaliação clínica para estabelecer a porcentagem de sucesso (Teste Exato de Fisher), análise radiográfica para quantificar a perda óssea em altura (programa de análise de imagens KS300-Zeiss®, ANOVA) e análise histológica para descrever as características da interface osso/implante. A análise dos dados demonstrou: 1) Grupos 1, 2, 4 e 5 - taxa de sucesso, quantidade de perda óssea em altura e interação osso/implante semelhantes; 2) Grupo 3 - taxa de insucesso e quantidade de perda óssea significantemente maiores que os demais grupos, além de apresentar ausência de interação osso/implante. Os resultados clínicos, radiográficos e histológicos revelados nos grupos submetidos à carga ortodôntica imediata em relação aos grupos sem carga demonstraram que a perda óssea na região da crista óssea periimplantar é aceitável e não compromete a estabilidade clínica dos implantes. Desta forma, a utilização de carga imediata para ancoragem em Ortodontia não prejudica a posterior utilização desses implantes para a reabilitação protética, objetivo primário da indicação deste protocolo. Estudos clínicos prospectivos são necessários para comprovar estes dados. / This research aimed at evaluating the success rate, the bone height loss, and the bone/implant interface in three different protocols: 1) osseointegrated implants maintained without load during a repair period of 120 days; 2) osseointegrated implants submitted to occlusal interferences; and 3) immediately loaded osseointegrated implants for orthodontic anchorage. Twelve BR-1 minipigs were used, in which 70 osseointegrated titanium implants were inserted (3.75mm diameter x 8.50mm length), divided into 5 groups: Group 1 (n=12), submerged implants without load; Group 2 (n=6), implants without load in extraction sites; Group 3 (n=12), implants exposed to occlusal interferences; Group 4 (n=20), exposed implants submitted to immediate orthodontic load; Group 5 (n=20), exposed implants inserted in extraction sites and submitted to immediate orthodontic load. At the end of the experimental period, the animals were euthanized and biopsies of the areas of interest were harvested. The clinical analysis (Exact Fisher Test) revealed the success rate of the inserted implants, the radiographic analysis quantified the bone height loss (image analysis program KS300-Zeiss®, ANOVA), and the histological analysis showed the bone/implant interface characteristics. The data analysis revealed: 1) Groups 1, 2, 4 and 5 - similar success rate, bone height loss and bone/implant interface characteristics; 2) Group 3 - statistically greater fail rate and bone height loss, and absence of bone/implant interaction characteristics. Clinical, radiographic and histological results presented in the groups submitted to immediate orthodontic load compared with the other without load demonstrated that the bone loss in the bone crest area is acceptable, and does not compromise the clinical stability of the implants. Therefore, the use of immediate load for orthodontic anchorage did not jeopardize the subsequent use of the implants for oral prosthetic rehabilitation, the main objective of this protocol. Further clinical studies are necessary to confirm these data.
|
2 |
Proposta conceitual de uma instalação para manuseio de mini porcos (minipigs) utilizados em pesquisas científicas / Conceptual proposal of a facility for handling minipigs used in scientific researchLainetti, Elizabeth Brigagão de Faria 17 December 2018 (has links)
Para a realização de pesquisas científicas biológicas universais e reprodutivas, é fundamental a produção e o fornecimento de animais de laboratório de alta qualidade. Contudo, a qualidade e a saúde desses animais dependem, em grande parte, das instalações disponíveis para a sua produção e alojamento, de forma a garantir a qualidade sanitária e o seu bem-estar, respeitando os princípios éticos que regem a atividade. Nas instalações destinadas a criação, manutenção e experimentação com animais de laboratório são adotadas diretrizes, tanto nacionais como internacionais, para garantir a biossegurança e o bem-estar animal. Além disso, as instalações devem preencher outros requisitos, tais como: a funcionalidade dos ambientes, que devem possibilitar o manejo adequado e eficiente dos animais, facilitando a execução das atividades rotineiras; a climatização ambiental; a instalação de barreiras sanitárias para limitar e impedir o acesso de agentes indesejáveis; o respeito a princípios ergonômicos, para proporcionar um ambiente seguro e o bem-estar dos operadores; a biossegurança, para prevenir, minimizar ou eliminar riscos à saúde do homem e dos animais, a preservação do meio ambiente e a qualidade dos resultados. Dessa forma, o projeto das instalações é de importância vital para que os requisitos mencionados sejam atingidos, com a obtenção de animais sadios, com o mínimo de estresse, proporcionando o bem-estar e reduzindo variações que podem afetar os resultados de pesquisa. Neste documento, é apresentada uma introdução com a importância do suíno na medicina e na experimentação animal, além de alguns parâmetros importantes adotados na construção de instalações destinadas à criação e alojamento desta espécie. Finalmente, é apresentado um projeto conceitual de uma instalação, que reunirá características que representem o estado-da-arte sobre o assunto, para que o espaço destinado ao alojamento dos animais atenda, da melhor maneira, as recomendações sobre aspectos inerentes dos animais de laboratório, com relação à saúde, à alimentação, controle da transmissão de doenças, á adequação das instalações às exigências e às normas internacionais que visam o bem-estar animal. O projeto da instalação reunirá características únicas e inéditas, para que seja possível realizar pesquisas científicas avançadas, contribuindo para o crescimento da ciência nacional, bem como para o desenvolvimento inovador no âmbito da CNEN. / In order to carry out outstanding universal and reproductive biological scientific research, the production and supply of high quality laboratory animals are of fundamental importance. However, the quality and health of these animals depends on a large extent on the facilities available for their production and housing in order to ensure the sanitary quality and their well-being, respecting the ethical principles governing the activity. National and international guidelines for facilities for breeding, maintenance and testing of laboratory animals are aimed, among other things, biosafety and animal welfare. In addition, facilities must meet other requirements, such as: the functionality of the environments, which should allow the proper and efficient management of the animals, facilitating the execution of routine activities; environmental air conditioning; the installation of sanitary barriers to limit and prevent access of undesirable agents; respect for ergonomic principles, to provide a safe environment and the well-being of operators; biosafety, to prevent, minimize or eliminate risks to the health of man and animals, the preservation of the environment and the quality of results. In this way, the design of the facilities is of vital importance in order to achieve the mentioned requirements, obtaining healthy animals with minimum stress, providing well-being and reducing variations that can affect the results of research. This paper presents an introduction to the importance of pig in medicine and animal experimentation, as well as some important parameters adopted in the construction of facilities for breeding and housing of this specie. Finally, a conceptual design of an installation is presented, which will bring up characteristics that represent the state of the art on the subject, so that the space destined to the housing of the animals meets, in the best way, the recommendations on inherent aspects of laboratory animals, with regard to health, food, control transmission of diseases, adaptation of facilities to international requirements and standards for animal welfare. The facilities project will bring also unique and unprecedented features, so that it is possible to carry out scientific cutting-edge research, contributing to the further development of national science, as well as innovative research within CNEN.
|
3 |
Carga imediata sobre implantes osseointegráveis para ancoragem ortodôntica: estudo em minipigs / Immediately loaded osseointegrated implants for orthodontic anchorage: study in minipigsPaula Vanessa Pedron Oltramari Navarro 17 December 2008 (has links)
O objetivo deste trabalho foi avaliar a taxa de sucesso, a quantidade de perda óssea em altura e a interação osso/implante para três diferentes protocolos: 1) implantes osseointegráveis mantidos sem carga durante período de reparo de 120 dias; 2) implantes submetidos a interferências oclusais; e 3) implantes que receberam carga imediata para ancoragem ortodôntica. Foram utilizados doze minipigs BR-1, nos quais foram instalados 70 implantes osseointegráveis de titânio (3,75mm diâmetro x 8,50mm comprimento), divididos em 5 grupos: Grupo 1 (n=12), implantes sem carga sepultados na mesial de caninos; Grupo 2 (n=6), implantes sem carga em áreas de extração; Grupo 3 (n=12), implantes expostos a interferências oclusais; Grupo 4 (n=20), implantes submetidos à carga ortodôntica imediata; Grupo 5 (n=20), implantes instalados em áreas de extração e submetidos à carga ortodôntica imediata. Ao término do período experimental, os animais foram eutanasiados e biópsias da região de interesse coletadas. Realizou-se avaliação clínica para estabelecer a porcentagem de sucesso (Teste Exato de Fisher), análise radiográfica para quantificar a perda óssea em altura (programa de análise de imagens KS300-Zeiss®, ANOVA) e análise histológica para descrever as características da interface osso/implante. A análise dos dados demonstrou: 1) Grupos 1, 2, 4 e 5 - taxa de sucesso, quantidade de perda óssea em altura e interação osso/implante semelhantes; 2) Grupo 3 - taxa de insucesso e quantidade de perda óssea significantemente maiores que os demais grupos, além de apresentar ausência de interação osso/implante. Os resultados clínicos, radiográficos e histológicos revelados nos grupos submetidos à carga ortodôntica imediata em relação aos grupos sem carga demonstraram que a perda óssea na região da crista óssea periimplantar é aceitável e não compromete a estabilidade clínica dos implantes. Desta forma, a utilização de carga imediata para ancoragem em Ortodontia não prejudica a posterior utilização desses implantes para a reabilitação protética, objetivo primário da indicação deste protocolo. Estudos clínicos prospectivos são necessários para comprovar estes dados. / This research aimed at evaluating the success rate, the bone height loss, and the bone/implant interface in three different protocols: 1) osseointegrated implants maintained without load during a repair period of 120 days; 2) osseointegrated implants submitted to occlusal interferences; and 3) immediately loaded osseointegrated implants for orthodontic anchorage. Twelve BR-1 minipigs were used, in which 70 osseointegrated titanium implants were inserted (3.75mm diameter x 8.50mm length), divided into 5 groups: Group 1 (n=12), submerged implants without load; Group 2 (n=6), implants without load in extraction sites; Group 3 (n=12), implants exposed to occlusal interferences; Group 4 (n=20), exposed implants submitted to immediate orthodontic load; Group 5 (n=20), exposed implants inserted in extraction sites and submitted to immediate orthodontic load. At the end of the experimental period, the animals were euthanized and biopsies of the areas of interest were harvested. The clinical analysis (Exact Fisher Test) revealed the success rate of the inserted implants, the radiographic analysis quantified the bone height loss (image analysis program KS300-Zeiss®, ANOVA), and the histological analysis showed the bone/implant interface characteristics. The data analysis revealed: 1) Groups 1, 2, 4 and 5 - similar success rate, bone height loss and bone/implant interface characteristics; 2) Group 3 - statistically greater fail rate and bone height loss, and absence of bone/implant interaction characteristics. Clinical, radiographic and histological results presented in the groups submitted to immediate orthodontic load compared with the other without load demonstrated that the bone loss in the bone crest area is acceptable, and does not compromise the clinical stability of the implants. Therefore, the use of immediate load for orthodontic anchorage did not jeopardize the subsequent use of the implants for oral prosthetic rehabilitation, the main objective of this protocol. Further clinical studies are necessary to confirm these data.
|
4 |
Proposta conceitual de uma instalação para manuseio de mini porcos (minipigs) utilizados em pesquisas científicas / Conceptual proposal of a facility for handling minipigs used in scientific researchElizabeth Brigagão de Faria Lainetti 17 December 2018 (has links)
Para a realização de pesquisas científicas biológicas universais e reprodutivas, é fundamental a produção e o fornecimento de animais de laboratório de alta qualidade. Contudo, a qualidade e a saúde desses animais dependem, em grande parte, das instalações disponíveis para a sua produção e alojamento, de forma a garantir a qualidade sanitária e o seu bem-estar, respeitando os princípios éticos que regem a atividade. Nas instalações destinadas a criação, manutenção e experimentação com animais de laboratório são adotadas diretrizes, tanto nacionais como internacionais, para garantir a biossegurança e o bem-estar animal. Além disso, as instalações devem preencher outros requisitos, tais como: a funcionalidade dos ambientes, que devem possibilitar o manejo adequado e eficiente dos animais, facilitando a execução das atividades rotineiras; a climatização ambiental; a instalação de barreiras sanitárias para limitar e impedir o acesso de agentes indesejáveis; o respeito a princípios ergonômicos, para proporcionar um ambiente seguro e o bem-estar dos operadores; a biossegurança, para prevenir, minimizar ou eliminar riscos à saúde do homem e dos animais, a preservação do meio ambiente e a qualidade dos resultados. Dessa forma, o projeto das instalações é de importância vital para que os requisitos mencionados sejam atingidos, com a obtenção de animais sadios, com o mínimo de estresse, proporcionando o bem-estar e reduzindo variações que podem afetar os resultados de pesquisa. Neste documento, é apresentada uma introdução com a importância do suíno na medicina e na experimentação animal, além de alguns parâmetros importantes adotados na construção de instalações destinadas à criação e alojamento desta espécie. Finalmente, é apresentado um projeto conceitual de uma instalação, que reunirá características que representem o estado-da-arte sobre o assunto, para que o espaço destinado ao alojamento dos animais atenda, da melhor maneira, as recomendações sobre aspectos inerentes dos animais de laboratório, com relação à saúde, à alimentação, controle da transmissão de doenças, á adequação das instalações às exigências e às normas internacionais que visam o bem-estar animal. O projeto da instalação reunirá características únicas e inéditas, para que seja possível realizar pesquisas científicas avançadas, contribuindo para o crescimento da ciência nacional, bem como para o desenvolvimento inovador no âmbito da CNEN. / In order to carry out outstanding universal and reproductive biological scientific research, the production and supply of high quality laboratory animals are of fundamental importance. However, the quality and health of these animals depends on a large extent on the facilities available for their production and housing in order to ensure the sanitary quality and their well-being, respecting the ethical principles governing the activity. National and international guidelines for facilities for breeding, maintenance and testing of laboratory animals are aimed, among other things, biosafety and animal welfare. In addition, facilities must meet other requirements, such as: the functionality of the environments, which should allow the proper and efficient management of the animals, facilitating the execution of routine activities; environmental air conditioning; the installation of sanitary barriers to limit and prevent access of undesirable agents; respect for ergonomic principles, to provide a safe environment and the well-being of operators; biosafety, to prevent, minimize or eliminate risks to the health of man and animals, the preservation of the environment and the quality of results. In this way, the design of the facilities is of vital importance in order to achieve the mentioned requirements, obtaining healthy animals with minimum stress, providing well-being and reducing variations that can affect the results of research. This paper presents an introduction to the importance of pig in medicine and animal experimentation, as well as some important parameters adopted in the construction of facilities for breeding and housing of this specie. Finally, a conceptual design of an installation is presented, which will bring up characteristics that represent the state of the art on the subject, so that the space destined to the housing of the animals meets, in the best way, the recommendations on inherent aspects of laboratory animals, with regard to health, food, control transmission of diseases, adaptation of facilities to international requirements and standards for animal welfare. The facilities project will bring also unique and unprecedented features, so that it is possible to carry out scientific cutting-edge research, contributing to the further development of national science, as well as innovative research within CNEN.
|
5 |
Comparison of piezoimplants versus conventional cylindrical implants in minipigs: stability analysisCorzo, Lorena 14 March 2018 (has links)
AIM: To compare the stability of a non-cylindrical implant using piezoelectric drilling (Piezoimplant) with a cylindrical implant with conventional drilling (Nobel Biocare™).
MATERIALS AND METHODS: Three adult female Gottingen miniature pigs were used for the surgical implantation. Three implants on each quadrant, randomized split-mouth design using cylindrical or non-cylindrical implants (n=36). Osteotomies were prepared using either conventional drilling technique as per manufacturer’s instruction (Nobel Biocare™) or using piezoelectric drilling (Piezotome® (P2) (Satelec Acteon, Merignac, France) with new implant prototype tips (Fraunhofer Center for Manufacturing Innovation). The minipigs were sacrificed at 4, 8 and 12-weeks. Stability tests (three per implant) using wireless Periotest® “M” were done at the start point and after euthanization.
RESULTS: R-square (ANOVA) test was plotted comparing implant design, weeks 4, 8 and 12, and location (mandible and maxilla) for stability analysis. In this model, the R-square is only 0.51, which indicates only 51% of the response variability can be explained by the fitted model. Among all the 3 factors, group (experiment vs control) is the most significant one, followed by week. Location significance is the least among the three factors.
CONCLUSION: In mandibular and maxillary sites in minipigs where non-cylindrical prototype implants (piezoimplant) were inserted by piezoelectric site preparation, statistically significant differences were found between control and test group stability measurements, but no differences in week (4, 8 or 12) and location among the two groups (mandible and maxilla). Stability was like the cylindrical implants. Meaning that Piezoimplants could be an alternative for narrow residual ridges. / 2020-03-14T00:00:00Z
|
6 |
Eignung eines neuartigen Hydrogels zur zellbasierten Therapie chondraler Defekte im Knie von MinipigsZaß, Gesa 06 November 2015 (has links) (PDF)
Nicht behandelte Knorpelschäden führen langfristig zum Verschleiß des Gelenks – der Arthrose. Eine vielversprechende Möglichkeit zur Behandlung von Knorpelschäden ist die Matrix-assoziierte Chondrozytenimplantation. In der vorliegenden Dissertationsarbeit sollte die neuartige Matrix NOVOCART® Inject der Firma TETEC® auf ihre Eignung für die Therapie von Knorpeldefekten untersucht und ihre potentiellen Effekte im Vergleich zu dem bereits in der klinischen Anwendung befindlichen Biomaterial Fibrin charakterisiert werden. Für diese Studie wurden bei insgesamt 12 Göttinger Minipigs jeweils zwei vollschichtige Defekte (Ø 6mm) auf den medialen Femurkondylen beider Knie gesetzt und mit humanen Chondrozyten, die entweder in NOVOCART® Inject oder Fibringel eingebettet waren, gefüllt. Zellfreie Träger dienten jeweils als Kontrolle. Nach zwei und vier Wochen wurde die Defektfüllung, Biokompatibilität, Wirtszellanlockung und der Verbleib der implantierten Zellen sowie die Regeneratqualität histologisch und auf Genexpressionsebene evaluiert.
Es konnte nachgewiesen werden, dass NOVOCART® Inject auch ohne Membranabdeckung eine gute Defektfüllung erzielt. Es ist biokompatibel und weist keine signifikant erhöhten Entzündungszeichen gegenüber Fibringel auf. Des Weiteren konnte eine vergleichbare Regeneratqualität im Vergleich zum Fibringel im porzinen Tiermodell erreicht werden. Unabhängig vom verwendeten Trägermaterial überdauerten die xenogen transplantierten Zellen im vorliegenden Defektmodell nur kurzfristig. Wir fanden Hinweise auf eine Immunreaktion unter Beteiligung von Makrophagen, die ursächlich für das Verschwinden der implantierten Zellen sein könnten. Die Ergebnisse unserer Untersuchungen stellen folglich die häufig diskutierte Theorie des immunpriviligierten Status der Chondrozyten in Frage.
|
7 |
Avaliação da resistência à flexão de mini-implantes desenvolvidos para ancoragem esquelética do aparelho de Herbst - Estudo em Minipig br1 / Flexure resistance evaluation of mini implants prototypes developed for Herbst appliance anchorage Study in Minipig br1Batista, Klaus Barretto dos Santos Lopes 23 April 2010 (has links)
Um efeito colateral indesejável do uso do aparelho de Herbst é a vestibularização excessiva dos incisivos inferiores que pode estar relacionada à retração gengival, à perda óssea marginal e à reabsorção radicular. A ancoragem esquelética do aparelho de Herbst poderia evitar estes problemas. O objetivo do presente estudo foi o de avaliar, em Minipigs br1, a resistência à flexão de protótipos de mini-implantes desenvolvidos para ancoragem do aparelho de Herbst, comparar a resistência dos protótipos entre as duas regiões escolhidas para inserção e avaliar se os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas. Após o cálculo do tamanho da amostra, 13 protótipos de mini-implantes foram colocados nas regiões posterior da maxila e anterior da mandíbula de três Minipigs br1, após terem sido mortos. Corpos de prova contendo os protótipos de mini-implantes inseridos em osso foram submetidos a uma força de flexão por engastamento simples utilizandose uma máquina universal de ensaios mecânicos Instron, calculando-se a média e o desvio padrão para cada região. Com o objetivo de comparar a resistência dos protótipos entre as regiões de inserção foi utilizado o Teste t de Student para duas amostras não pareadas. O teste de hipótese foi realizado para cada região para avaliar se os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas. Para fins de comparação foram consideradas forças ortopédicas acima de 1,0 kgf. O nível de significância adotado foi P < 0,05. Os protótipos de miniimplantes apresentaram resistência à força de flexão de 13,86 kgf (DP = 2,3) para a região posterior da maxila e 20,55 kgf (DP = 5,2) para a região anterior da mandíbula. Houve diferença estatisticamente significativa entre as duas regiões com relação à força de resistência dos mini-implantes (P = 0,015), sendo que a resistência maior foi na região anterior da mandíbula. A hipótese de que os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas foi confirmada para as regiões posterior da maxila e anterior da mandíbula. Os autores concluíram que, em Minipigs br1, os protótipos de mini-implantes desenvolvidos para a ancoragem do aparelho de Herbst foram capazes de resistir a forças entre 13,86 e 20,55 kgf, sendo estatisticamente mais resistentes na região anterior da mandíbula e capazes de suportar forças ortopédicas. / An undesirable tooth movement resulting from use of the Herbst appliance is the excessive proclination of the anterior mandibular teeth, which is commonly associated with gingival recession, marginal bone loss, and root resorption. Skeletal anchorage of the Herbst appliance could prevent these problems. The present study was designed to evaluate, in Minipigs br1, the flexure resistance of prototype miniimplants developed for Herbst appliance anchorage, to compare the prototype resistance between the regions in which the mini-implants were placed, and to test the hypothesis that these mini-implant prototypes can withstand orthopedic forces. After calculation of sample size, 13 mini-implant prototypes (2 mm in diameter x 10 mm long) were inserted in the posterior region of the maxilla and the anterior region of the mandible, in three recently killed minipigs. The specimens were submitted to a single cantilever flexure test using an Instron testing machine. Mean and standard deviation were calculated for each region. To compare the resistance of the prototypes between the sites of mini-implant insertion, a 2-Sample Students t test was calculated. The test was carried out individually for each region, to evaluate if the prototype mini-implants developed for Herbst appliance anchorage could withstand orthopedic forces. Orthopedic forces above 1.0 kgf were considered. The level of significance was set at P < 0.05. The prototype mini-implant showed a flexure strength of 13.86 kgf (SD = 2.3) for the posterior region of the maxilla, and 20.55 kgf (SD = 5.2) for the anterior region of the mandible. A significant statistically difference was found in the resistance of the prototypes between the two regions (P = 0.015). The hypothesis that the prototype mini-implants can withstand orthopedic forces was confirmed. The authors concluded that, in Minipigs br1, the prototype mini-implants developed for Herbst appliance anchorage could resist forces from 13.86 to 20.55 kgf, were statistically more resistant in the anterior region of the mandible, and were capable of withstanding orthopedic forces.
|
8 |
Avaliação da resistência à flexão de mini-implantes desenvolvidos para ancoragem esquelética do aparelho de Herbst - Estudo em Minipig br1 / Flexure resistance evaluation of mini implants prototypes developed for Herbst appliance anchorage Study in Minipig br1Klaus Barretto dos Santos Lopes Batista 23 April 2010 (has links)
Um efeito colateral indesejável do uso do aparelho de Herbst é a vestibularização excessiva dos incisivos inferiores que pode estar relacionada à retração gengival, à perda óssea marginal e à reabsorção radicular. A ancoragem esquelética do aparelho de Herbst poderia evitar estes problemas. O objetivo do presente estudo foi o de avaliar, em Minipigs br1, a resistência à flexão de protótipos de mini-implantes desenvolvidos para ancoragem do aparelho de Herbst, comparar a resistência dos protótipos entre as duas regiões escolhidas para inserção e avaliar se os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas. Após o cálculo do tamanho da amostra, 13 protótipos de mini-implantes foram colocados nas regiões posterior da maxila e anterior da mandíbula de três Minipigs br1, após terem sido mortos. Corpos de prova contendo os protótipos de mini-implantes inseridos em osso foram submetidos a uma força de flexão por engastamento simples utilizandose uma máquina universal de ensaios mecânicos Instron, calculando-se a média e o desvio padrão para cada região. Com o objetivo de comparar a resistência dos protótipos entre as regiões de inserção foi utilizado o Teste t de Student para duas amostras não pareadas. O teste de hipótese foi realizado para cada região para avaliar se os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas. Para fins de comparação foram consideradas forças ortopédicas acima de 1,0 kgf. O nível de significância adotado foi P < 0,05. Os protótipos de miniimplantes apresentaram resistência à força de flexão de 13,86 kgf (DP = 2,3) para a região posterior da maxila e 20,55 kgf (DP = 5,2) para a região anterior da mandíbula. Houve diferença estatisticamente significativa entre as duas regiões com relação à força de resistência dos mini-implantes (P = 0,015), sendo que a resistência maior foi na região anterior da mandíbula. A hipótese de que os protótipos de mini-implantes seriam capazes de suportar forças ortopédicas foi confirmada para as regiões posterior da maxila e anterior da mandíbula. Os autores concluíram que, em Minipigs br1, os protótipos de mini-implantes desenvolvidos para a ancoragem do aparelho de Herbst foram capazes de resistir a forças entre 13,86 e 20,55 kgf, sendo estatisticamente mais resistentes na região anterior da mandíbula e capazes de suportar forças ortopédicas. / An undesirable tooth movement resulting from use of the Herbst appliance is the excessive proclination of the anterior mandibular teeth, which is commonly associated with gingival recession, marginal bone loss, and root resorption. Skeletal anchorage of the Herbst appliance could prevent these problems. The present study was designed to evaluate, in Minipigs br1, the flexure resistance of prototype miniimplants developed for Herbst appliance anchorage, to compare the prototype resistance between the regions in which the mini-implants were placed, and to test the hypothesis that these mini-implant prototypes can withstand orthopedic forces. After calculation of sample size, 13 mini-implant prototypes (2 mm in diameter x 10 mm long) were inserted in the posterior region of the maxilla and the anterior region of the mandible, in three recently killed minipigs. The specimens were submitted to a single cantilever flexure test using an Instron testing machine. Mean and standard deviation were calculated for each region. To compare the resistance of the prototypes between the sites of mini-implant insertion, a 2-Sample Students t test was calculated. The test was carried out individually for each region, to evaluate if the prototype mini-implants developed for Herbst appliance anchorage could withstand orthopedic forces. Orthopedic forces above 1.0 kgf were considered. The level of significance was set at P < 0.05. The prototype mini-implant showed a flexure strength of 13.86 kgf (SD = 2.3) for the posterior region of the maxilla, and 20.55 kgf (SD = 5.2) for the anterior region of the mandible. A significant statistically difference was found in the resistance of the prototypes between the two regions (P = 0.015). The hypothesis that the prototype mini-implants can withstand orthopedic forces was confirmed. The authors concluded that, in Minipigs br1, the prototype mini-implants developed for Herbst appliance anchorage could resist forces from 13.86 to 20.55 kgf, were statistically more resistant in the anterior region of the mandible, and were capable of withstanding orthopedic forces.
|
9 |
Venöse Revaskularisation bei Vorliegen einer Mikro- und Makroangiopathie / Venous revascularisation in a model of cardiac microangiopathy and macroangiopathySchiller, Julia Virginie 23 August 2011 (has links) (PDF)
In der vorliegenden Arbeit wurde die venöse Revaskularisation bei Vorliegen einer Mikro- und Makroangiopathie untersucht. Die Zielgruppe dieser Methodik sind Patienten, die aus kardiologischer und herzchirurgischer Sicht austherapiert sind, für die weder ein Stent noch eine konventionelle Bypassoperation in Frage kommt. Das betrifft Patienten mit disseziierten Gefäßen, mit schwerer diffuser koronarer Herzerkrankung oder small vessel disease. Für diese Patienten ist derzeit keine optimale Therapie vorhanden. Es handelt sich somit um eine ultima ratio-Therapie. Zur Prüfung der Effektivität der Methode bei beschriebenem Krankheitsbild wurde in Minipigs eine Mikroangiopathie durch Injektion von Mikrosphären (Durchmesser 100µm) in den linken Hauptstamm erzeugt. Nach 7 Wochen Krankheitsentwicklung der Mirkoangiopahtie wurde eine hochgradige Stenose des Ramus interventricularis anterior (RIVA) hervorgerufen, welches die Makroangiopathie simulieren sollte. Anschließend wurden die Tiere der Therapiegruppe mit einem Bypass von der Arteria mammaria auf die Begleitvene des RIVA versorgt. Dabei wurde die Begleitvene proximal der Anastomose ligiert. Die Kontrollgruppe blieb ohne Therapie. Die Stenose und der Bypass wurden angiographisch dargestellt. Nach 17 Wochen wurde bei allen Tieren eine Herzkatheteruntersuchung durchgeführt, um die Stenose und den Bypass zu beurteilen. Als Maß für die Herzleistung wurde zu allen 3 Versuchsteilen die Ejektionsfraktion bestimmt. Anhand der Ejektionsfraktion konnte die Überlegenheit der venösen Revaskularisation als Therapie gezeigt werden. 7 Wochen nach Injektion der Mikrosphären fielen die Werte der Ejektionsfraktion beider Gruppen ab. Nach 17 Wochen nahm die Ejektionfraktion der Therapiegruppe, die in der Zwischenzeit mit einem Bypass versorgt wurden, wieder deutlich zu und die der Kontrollgrupppe sank weiter ab. Zusätzlich wurden die entnommenen Herzen histologisch untersucht. Dabei zeigte sich ein Umbau des Gefäßsystems im Bereich der angeschlossenen Vene. / Objective: Many patients with significant arterioclerosis of the heart cannot benefit from a coronary artery bypass and other methods because they have macroangiopathy combined with microangiopathy. We evaluated the efficiency of venous revascularization in minipigs with macroangiopathy combined with microangiopathy in a chronic model of 3 months.
Histological analysis of arterial and venous vessels of the heart was conducted.
Methods: In left anterior descending artery (LAD) microspheres (diameter 100µm) were injected in 24 minipigs (12 control group, 12 therapy group). 7 weeks later a stenosis of the LAD was performed in both groups with an average of 84,6 ± 4,3%. In therapy group left internal thoracic artery was anastomosed to the concomitant vein of the LAD in beating heart surgery. The flow of bypass was proved in angiography and the flow rate was measured by ultrasound. 10 weeks later bypass of therapy group and stenosis of both groups were verified in angiography. At the beginning of every part of the experiment the ejection fraction in both groups was evaluated with echocardiography. Hemodynamic monitoring was performed throughout the experiment.
In histological analysis arterial and venous vessels in left atrium, right atrium, septum and area of anastomosis were evaluated in the thickness of wall and area of lumen.
Results: In ejection fraction a significant difference between control and therapy group was seen. After performing the bypass, the ejection fraction in therapy group increased, while it decreased in control group in the same period of time of 10 weeks.
In the histological analysis a non-classifiable type of vessel was found only in the area of the anastomosis. The vessel had a a large area of lumen and a thick wall due to media hyperplasia.
Conclusion: Venous revascularization of the concomitant vein of the LAD via bypass of the left thoracic artery in a chronic model improves cardiac funcion and is therefore an effective method when having microangiopathy and macroangiopathy combined.
The non-classifiable type of vessel are most likely arterialized veins which underwent a structural change of the wall due to the arterial blood pressure.
|
10 |
Eignung eines neuartigen Hydrogels zur zellbasierten Therapie chondraler Defekte im Knie von MinipigsZaß, Gesa 19 May 2015 (has links)
Nicht behandelte Knorpelschäden führen langfristig zum Verschleiß des Gelenks – der Arthrose. Eine vielversprechende Möglichkeit zur Behandlung von Knorpelschäden ist die Matrix-assoziierte Chondrozytenimplantation. In der vorliegenden Dissertationsarbeit sollte die neuartige Matrix NOVOCART® Inject der Firma TETEC® auf ihre Eignung für die Therapie von Knorpeldefekten untersucht und ihre potentiellen Effekte im Vergleich zu dem bereits in der klinischen Anwendung befindlichen Biomaterial Fibrin charakterisiert werden. Für diese Studie wurden bei insgesamt 12 Göttinger Minipigs jeweils zwei vollschichtige Defekte (Ø 6mm) auf den medialen Femurkondylen beider Knie gesetzt und mit humanen Chondrozyten, die entweder in NOVOCART® Inject oder Fibringel eingebettet waren, gefüllt. Zellfreie Träger dienten jeweils als Kontrolle. Nach zwei und vier Wochen wurde die Defektfüllung, Biokompatibilität, Wirtszellanlockung und der Verbleib der implantierten Zellen sowie die Regeneratqualität histologisch und auf Genexpressionsebene evaluiert.
Es konnte nachgewiesen werden, dass NOVOCART® Inject auch ohne Membranabdeckung eine gute Defektfüllung erzielt. Es ist biokompatibel und weist keine signifikant erhöhten Entzündungszeichen gegenüber Fibringel auf. Des Weiteren konnte eine vergleichbare Regeneratqualität im Vergleich zum Fibringel im porzinen Tiermodell erreicht werden. Unabhängig vom verwendeten Trägermaterial überdauerten die xenogen transplantierten Zellen im vorliegenden Defektmodell nur kurzfristig. Wir fanden Hinweise auf eine Immunreaktion unter Beteiligung von Makrophagen, die ursächlich für das Verschwinden der implantierten Zellen sein könnten. Die Ergebnisse unserer Untersuchungen stellen folglich die häufig diskutierte Theorie des immunpriviligierten Status der Chondrozyten in Frage.
|
Page generated in 0.0565 seconds