• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • 1
  • 1
  • Tagged with
  • 25
  • 25
  • 14
  • 11
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise de técnicas para o estabelecimento de modelos digitais de terrenos - DTM / not available

Campos, Ilce de Oliveira 17 March 1995 (has links)
A representação do relevo topográfico, foi durante muito tempo uma preocupação para os profissionais da área de topografia. O traçado de curvas de nível a partir de um levantamento era feito manualmente, com a determinação dos valores intermediários através de interpolação linear. Com o desenvolvimento da informática e sua introdução para o tratamento de dados em mensuração, surgiu uma nova tecnologia que permite a geração automática de um modelo que descreve analiticamente a superfície topográfica, trata-se dos MODELOS DIGITAIS DE TERRENOS (DTM). Esses modelos constituem uma ferramenta importante no desenvolvimento de vários projetos, tais como, projetos de vias, intersecções, movimento de terra (corte/aterro), drenagem, parcelamento do solo (loteamentos) e outros. O presente trabalho tem como objetivo fazer uma abordagem dos aspectos relativos às técnicas para o estabelecimento desses modelos, descrevendo os principais métodos de aquisição de dados, de interpolação e o processo de geração dos modelos. Finalmente é descrito um panorama do desenvolvimento desses sistemas com suas principais aplicações. / The representation of the topography surface was for a long time the main proposal by the surveyer engenneres. Threading of the contour for surveying is usually made handly with the mean values obtained through the linear interpolation. The development of computer science provide an easier manner of data treatment in measuring. As a result, a new technology was introduced to generate automatically a model for the mathematic description of the topography. They are called of Digital Terrain Model (DTM). These models are very important tool for the development of several projects, such as, highway and intersection projects and land movements (cut/fill), draining, lands parceling and others. This paper has as objective to focus the technics to use these models, describing the main methods to obtain the data, interpolation and process to generate the models. Finally, it is described the development of these systems and it\'s main application.
2

Análise de técnicas para o estabelecimento de modelos digitais de terrenos - DTM / not available

Ilce de Oliveira Campos 17 March 1995 (has links)
A representação do relevo topográfico, foi durante muito tempo uma preocupação para os profissionais da área de topografia. O traçado de curvas de nível a partir de um levantamento era feito manualmente, com a determinação dos valores intermediários através de interpolação linear. Com o desenvolvimento da informática e sua introdução para o tratamento de dados em mensuração, surgiu uma nova tecnologia que permite a geração automática de um modelo que descreve analiticamente a superfície topográfica, trata-se dos MODELOS DIGITAIS DE TERRENOS (DTM). Esses modelos constituem uma ferramenta importante no desenvolvimento de vários projetos, tais como, projetos de vias, intersecções, movimento de terra (corte/aterro), drenagem, parcelamento do solo (loteamentos) e outros. O presente trabalho tem como objetivo fazer uma abordagem dos aspectos relativos às técnicas para o estabelecimento desses modelos, descrevendo os principais métodos de aquisição de dados, de interpolação e o processo de geração dos modelos. Finalmente é descrito um panorama do desenvolvimento desses sistemas com suas principais aplicações. / The representation of the topography surface was for a long time the main proposal by the surveyer engenneres. Threading of the contour for surveying is usually made handly with the mean values obtained through the linear interpolation. The development of computer science provide an easier manner of data treatment in measuring. As a result, a new technology was introduced to generate automatically a model for the mathematic description of the topography. They are called of Digital Terrain Model (DTM). These models are very important tool for the development of several projects, such as, highway and intersection projects and land movements (cut/fill), draining, lands parceling and others. This paper has as objective to focus the technics to use these models, describing the main methods to obtain the data, interpolation and process to generate the models. Finally, it is described the development of these systems and it\'s main application.
3

Avaliação do uso de modelos digitais de elevação em prognósticos de modelos de dispersão de gases na troposfera / Evaluation of Digital Elevation Models over Tropospheric Gases Dispersion Models Predictions

Meira, Lindolfo January 2007 (has links)
Pelo fato de que poucos trabalhos atualmente têm relatado acerca do impacto da resolução dos modelos digitais de elevação (MDEs) sobre as concentrações previstas por modelos de simulação da qualidade do ar, este estudo tenta estabelecer urna comparação básica entre dois distintos cenários de simulação, afim de embasar futuras investigações sobre o assunto. O foco está na formação e dispersão de ozônio sobre o estado do Rio Grande do Sul. No primeiro cenário de simulação, nenhum dado de elevação é considerado. No segundo, um MDE com resolução de 1 km, derivado de dados da MissãoTopográfiica do Ônibus Espacial (SRTM), é utilizado. Os modelos de qualidade do ar empregados são aqueles englobados pela dita interface Models-3, amplamente utilizados e respaldados pela Agência de Fmteção Ambiental Estadunidense (US-EPA). Dois domínios de simulação são implementados neste estudo: um domínio externo com 90x 90 células de 9 km cada, e um interno com 67x49 células de 3 km cada. Dados meteorológicos com, aproximadamente, 110 km de resolução, do Centm Nacional Estadunidense de Fr-evisão Ambiental (NCEP) também são usados nas simulações, bem corno dois outros conjuntos de dados do Institv,to BmsÜeiro de Geogmjia e Estatíst'ica (IBGE) e do Depar-tamento de Trânsito do Estado do Rio Grande do Sul (DETRAN-RS). Estes dois últimos usados na estimativa das emissões devidas à frota veicular da Região Metmpolitana de Porto Alegre(RMPA), tornada corno única contribuinte às emissões sobre a área estudada. Os resultados apresentaram marcadas diferenças entre um cenário e outro. Concentrações constantemente mais elevadas de ozônio foram observadas na presença do MDE enquanto, na ausência deste, as concentrações finais de ozônio baixaram os níveis à metade. Também os padrões de dispersão tiveram características bastante distintas, espalhando-se amplamente sobre a parte sul do domínio externo de simulação na ausência do MDE e, do contrário, espalhando-se de forma mais limitada sobre a parte sudoeste, com um jato observado em direção noroeste. Elevados níveis de concentração de ozônio foram observados bastante longe das fontes emissoras, atingindo cerca de 500 km em ambos os cenários. / As few works nowadays have reported on the impact of digital elevation nodels (DEMs) resolution over concentration predictions by air quality simulation models, this study attempts to establish a basic comparison betweeIl two different simulation scenarios, in order to support further investigation on this issue. The focus is on the ozone formation and dispersioll over the Rio Grande do Sul state. In the first simulation scenario, no elevation data is regarded. In the second one, DEM data with 1 km resolution, derived from the Shuttle Radar Topogmphic Mission (SRTM) is used. The air quality models employed are those which constitute the so-called Models-3 interface, widely used and supported by the United States Environmental Protection Agency (US-EPA). Two simulation domains are implemented in this study: the outermost domain with 90x90 cells with 9 km each, and the innermost one with 67x49 cells with 3 km each. Meteorology data with, approximately, 110 km resolution I'rom the National Genter for Environmental Prediction (NCEP) is also used in the simulations, as well as two other sets of data from the Brazilian Institute of Geography and Statistics (IBGE) and from the Rio Grande do Sul State Traffic Department (DETRAN-RS). These last two sets used to estimate emissions from the Metropolitan Arm of Porto Alegre (RMPA) vehicular fieet, taken as the only contributor to the emissions over the studied area. The results have presented marked differences from one scenario to the other. Sustained higher concentratiolls of ozone have been observed in the presence of the DEM data whilst, in the lack of it, final concentrations of ozone have dropped their levels to half. Also, dispersion patterns had quite distinguishable features, spreading widely over the south part of the outermost simulation domain in the lack of DEM data and, otherwise, spreading in a more narrow fashion over the south-west part, with a jet observed north-westwards. High levels of ozone concentration were abserved far away from the emission sources, reaching as far as 500 km in both scenarios.
4

Avaliação do uso de modelos digitais de elevação em prognósticos de modelos de dispersão de gases na troposfera / Evaluation of Digital Elevation Models over Tropospheric Gases Dispersion Models Predictions

Meira, Lindolfo January 2007 (has links)
Pelo fato de que poucos trabalhos atualmente têm relatado acerca do impacto da resolução dos modelos digitais de elevação (MDEs) sobre as concentrações previstas por modelos de simulação da qualidade do ar, este estudo tenta estabelecer urna comparação básica entre dois distintos cenários de simulação, afim de embasar futuras investigações sobre o assunto. O foco está na formação e dispersão de ozônio sobre o estado do Rio Grande do Sul. No primeiro cenário de simulação, nenhum dado de elevação é considerado. No segundo, um MDE com resolução de 1 km, derivado de dados da MissãoTopográfiica do Ônibus Espacial (SRTM), é utilizado. Os modelos de qualidade do ar empregados são aqueles englobados pela dita interface Models-3, amplamente utilizados e respaldados pela Agência de Fmteção Ambiental Estadunidense (US-EPA). Dois domínios de simulação são implementados neste estudo: um domínio externo com 90x 90 células de 9 km cada, e um interno com 67x49 células de 3 km cada. Dados meteorológicos com, aproximadamente, 110 km de resolução, do Centm Nacional Estadunidense de Fr-evisão Ambiental (NCEP) também são usados nas simulações, bem corno dois outros conjuntos de dados do Institv,to BmsÜeiro de Geogmjia e Estatíst'ica (IBGE) e do Depar-tamento de Trânsito do Estado do Rio Grande do Sul (DETRAN-RS). Estes dois últimos usados na estimativa das emissões devidas à frota veicular da Região Metmpolitana de Porto Alegre(RMPA), tornada corno única contribuinte às emissões sobre a área estudada. Os resultados apresentaram marcadas diferenças entre um cenário e outro. Concentrações constantemente mais elevadas de ozônio foram observadas na presença do MDE enquanto, na ausência deste, as concentrações finais de ozônio baixaram os níveis à metade. Também os padrões de dispersão tiveram características bastante distintas, espalhando-se amplamente sobre a parte sul do domínio externo de simulação na ausência do MDE e, do contrário, espalhando-se de forma mais limitada sobre a parte sudoeste, com um jato observado em direção noroeste. Elevados níveis de concentração de ozônio foram observados bastante longe das fontes emissoras, atingindo cerca de 500 km em ambos os cenários. / As few works nowadays have reported on the impact of digital elevation nodels (DEMs) resolution over concentration predictions by air quality simulation models, this study attempts to establish a basic comparison betweeIl two different simulation scenarios, in order to support further investigation on this issue. The focus is on the ozone formation and dispersioll over the Rio Grande do Sul state. In the first simulation scenario, no elevation data is regarded. In the second one, DEM data with 1 km resolution, derived from the Shuttle Radar Topogmphic Mission (SRTM) is used. The air quality models employed are those which constitute the so-called Models-3 interface, widely used and supported by the United States Environmental Protection Agency (US-EPA). Two simulation domains are implemented in this study: the outermost domain with 90x90 cells with 9 km each, and the innermost one with 67x49 cells with 3 km each. Meteorology data with, approximately, 110 km resolution I'rom the National Genter for Environmental Prediction (NCEP) is also used in the simulations, as well as two other sets of data from the Brazilian Institute of Geography and Statistics (IBGE) and from the Rio Grande do Sul State Traffic Department (DETRAN-RS). These last two sets used to estimate emissions from the Metropolitan Arm of Porto Alegre (RMPA) vehicular fieet, taken as the only contributor to the emissions over the studied area. The results have presented marked differences from one scenario to the other. Sustained higher concentratiolls of ozone have been observed in the presence of the DEM data whilst, in the lack of it, final concentrations of ozone have dropped their levels to half. Also, dispersion patterns had quite distinguishable features, spreading widely over the south part of the outermost simulation domain in the lack of DEM data and, otherwise, spreading in a more narrow fashion over the south-west part, with a jet observed north-westwards. High levels of ozone concentration were abserved far away from the emission sources, reaching as far as 500 km in both scenarios.
5

Avaliação do uso de modelos digitais de elevação em prognósticos de modelos de dispersão de gases na troposfera / Evaluation of Digital Elevation Models over Tropospheric Gases Dispersion Models Predictions

Meira, Lindolfo January 2007 (has links)
Pelo fato de que poucos trabalhos atualmente têm relatado acerca do impacto da resolução dos modelos digitais de elevação (MDEs) sobre as concentrações previstas por modelos de simulação da qualidade do ar, este estudo tenta estabelecer urna comparação básica entre dois distintos cenários de simulação, afim de embasar futuras investigações sobre o assunto. O foco está na formação e dispersão de ozônio sobre o estado do Rio Grande do Sul. No primeiro cenário de simulação, nenhum dado de elevação é considerado. No segundo, um MDE com resolução de 1 km, derivado de dados da MissãoTopográfiica do Ônibus Espacial (SRTM), é utilizado. Os modelos de qualidade do ar empregados são aqueles englobados pela dita interface Models-3, amplamente utilizados e respaldados pela Agência de Fmteção Ambiental Estadunidense (US-EPA). Dois domínios de simulação são implementados neste estudo: um domínio externo com 90x 90 células de 9 km cada, e um interno com 67x49 células de 3 km cada. Dados meteorológicos com, aproximadamente, 110 km de resolução, do Centm Nacional Estadunidense de Fr-evisão Ambiental (NCEP) também são usados nas simulações, bem corno dois outros conjuntos de dados do Institv,to BmsÜeiro de Geogmjia e Estatíst'ica (IBGE) e do Depar-tamento de Trânsito do Estado do Rio Grande do Sul (DETRAN-RS). Estes dois últimos usados na estimativa das emissões devidas à frota veicular da Região Metmpolitana de Porto Alegre(RMPA), tornada corno única contribuinte às emissões sobre a área estudada. Os resultados apresentaram marcadas diferenças entre um cenário e outro. Concentrações constantemente mais elevadas de ozônio foram observadas na presença do MDE enquanto, na ausência deste, as concentrações finais de ozônio baixaram os níveis à metade. Também os padrões de dispersão tiveram características bastante distintas, espalhando-se amplamente sobre a parte sul do domínio externo de simulação na ausência do MDE e, do contrário, espalhando-se de forma mais limitada sobre a parte sudoeste, com um jato observado em direção noroeste. Elevados níveis de concentração de ozônio foram observados bastante longe das fontes emissoras, atingindo cerca de 500 km em ambos os cenários. / As few works nowadays have reported on the impact of digital elevation nodels (DEMs) resolution over concentration predictions by air quality simulation models, this study attempts to establish a basic comparison betweeIl two different simulation scenarios, in order to support further investigation on this issue. The focus is on the ozone formation and dispersioll over the Rio Grande do Sul state. In the first simulation scenario, no elevation data is regarded. In the second one, DEM data with 1 km resolution, derived from the Shuttle Radar Topogmphic Mission (SRTM) is used. The air quality models employed are those which constitute the so-called Models-3 interface, widely used and supported by the United States Environmental Protection Agency (US-EPA). Two simulation domains are implemented in this study: the outermost domain with 90x90 cells with 9 km each, and the innermost one with 67x49 cells with 3 km each. Meteorology data with, approximately, 110 km resolution I'rom the National Genter for Environmental Prediction (NCEP) is also used in the simulations, as well as two other sets of data from the Brazilian Institute of Geography and Statistics (IBGE) and from the Rio Grande do Sul State Traffic Department (DETRAN-RS). These last two sets used to estimate emissions from the Metropolitan Arm of Porto Alegre (RMPA) vehicular fieet, taken as the only contributor to the emissions over the studied area. The results have presented marked differences from one scenario to the other. Sustained higher concentratiolls of ozone have been observed in the presence of the DEM data whilst, in the lack of it, final concentrations of ozone have dropped their levels to half. Also, dispersion patterns had quite distinguishable features, spreading widely over the south part of the outermost simulation domain in the lack of DEM data and, otherwise, spreading in a more narrow fashion over the south-west part, with a jet observed north-westwards. High levels of ozone concentration were abserved far away from the emission sources, reaching as far as 500 km in both scenarios.
6

Avaliação da acurácia altimétrica de modelos digitais de elevação no Brasil: um estudo sobre a distribuição dos erros altimétricos e a influência de valores outliers para o processo de análise

CARVALHO, Joao Alberto Batista de 12 December 2016 (has links)
Submitted by Alice Araujo (alice.caraujo@ufpe.br) on 2018-05-04T17:23:13Z No. of bitstreams: 1 DISSERTAÇÃO João Alberto Batista de Carvalho.pdf: 5423768 bytes, checksum: 52939bf6ee051675373488673f528ad8 (MD5) / Made available in DSpace on 2018-05-04T17:23:13Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO João Alberto Batista de Carvalho.pdf: 5423768 bytes, checksum: 52939bf6ee051675373488673f528ad8 (MD5) Previous issue date: 2016-12-12 / Os Modelos Digitais de Elevação (MDE) podem ser definidos como uma superfície matemática que representa de forma contínua a superfície terrestre. Estes possuem diversas aplicações em várias áreas das Geociências. Devida a sua importância, o MDE necessita ter um rigoroso processo de avaliação de qualidade, de forma a garantir o seu grau de aderência a superfície topográfica. No Brasil, o estimador de qualidade utilizado consiste no Padrão de Exatidão Cartográfica (PEC), atualizado posteriormente para Padrão de Exatidão Cartográfica dos Produtos Cartográficos Digitais (PEC-PCD). De forma complementar, também são utilizados para avaliação da acurácia testes de precisão e tendência. Diversas normas internacionais abordam a avaliação da qualidade altimétrica do MDE. Em especial, percebe-se nestas normas que a distribuição dos erros altimétricos é considerada não necessariamente como normal, o que gera padrões baseados em medidas como o percentil. Alguns autores consideram que a presença de valores outliers afetam a distribuição dos erros altimétricos, tornando-as não normal, além de influenciar em medidas como média e desvio-padrão. Este trabalho tem como objetivo verificar a hipótese de que a distribuição dos erros altimétricos de MDE não segue necessariamente a distribuição normal, bem como analisar a influência dos valores outliers em medidas estatísticas de dispersão e tendência central, nos valores dos testes de tendência e precisão e no processo de classificação do PEC-PCD. / Digital Elevation Models (DEM) can be defined as a mathematical surface that represents the Earth's surface continuously. These have diverse applications in various areas of Geosciences. Due to its importance, the DEM needs to have a rigorous process of quality evaluation, in order to guarantee its degree of adherence to the topographic surface. In Brazil, the quality estimator used consists of the Cartographic Accuracy Standard (PEC), later updated to Cartographic Accuracy Standard of Digital Cartographic Products (PEC-PCD). In addition, accuracy and trend tests are also used to evaluate the accuracy. Several international standards cover the assessment of the altimetric quality of the DEM. In particular, it can be seen in these rules that the distribution of altimetric errors is considered not necessarily normal, which generates patterns based on measures such as the percentile. Some authors consider that the presence of outliers affects the distribution of altimetric errors, making them non-normal, in addition to influencing measures such as mean and standard deviation. The aim of this work is to verify the hypothesis that the distribution of the MDE altimetric errors does not necessarily follow the normal distribution, as well as to analyze the influence of the outliers values on statistical measures of dispersion and central tendency, on the values of the trend and precision tests and In the PEC-PCD classification process.
7

Gesto técnico: interferências da modelagem digital na criação arquitetônica / Technical gesture: the interferences of digital modeling in the architectural conception.

Veloso, Pedro Luís Alves 16 May 2011 (has links)
A pesquisa investiga o complexo processo de informatização disciplinar da arquitetura, direcionando-se especificamente à abordagem das relações entre a concepção arquitetônica e o uso de modelos digitais. Nessa relação específica entre tecnologia informático-digital e criação toma-se como recorte privilegiado de estudo a produção das arquiteturas suportadas por técnicas digitais nas últimas duas décadas (1990-2010). Com esse intento, estipulam-se duas aproximações. A primeira evoca a compreensão da própria criação arquitetônica como prática disciplinada, por meio de uma revisão da teoria de projeto. Estabelece uma leitura do papel do homem e dos seus instrumentos no projeto arquitetônico, definindo-se critérios para o ensaio sobre as interferências da tecnologia digital. A segunda aproximação, retoma a filosofia do design proposta de Vilém Flusser. Nesse caso, a pesquisa situa os instrumentos tecnológicos como recurso de superação das limitações humanas, que, afetando as estruturas de pensamento e criação vigentes, delimitam novas relações entre homem, conhecimento, criatividade e realidade. Em especial são estabelecidas incursões teóricas a partir de conceitos propostos pelo filósofo: \"gesto de fazer\", \"aparelho\", \"imagem-técnica\", \"gesto do cálculo e da computação\" e, por fim, \"o programa\". Essas incursões propõem diálogos com outros teóricos do campo do conhecimento e estudos de caso que endossam a argumentação. Por fim, estabelecem-se considerações críticas sobre as interferências da tecnologia informático-digital na arquitetura, propondo-se perspectivas para a criação pautada nos modelos digitais. / This is a research about the complex computerization of Architecture discipline. It focuses on the relationship between architectural design and use of digital models. In this specific context between digital technology and human creation, the study of the production of Architecture supported by digital techniques in the last two decades (1990-2010) is a privileged study object. Considering this, the study stipulates two approaches. The first refers to the understanding of the architectural conception as a disciplined practice through a review of Design Theory. It establishes a lecture on the role of man and its tools in architectural design, defining criteria for the discussion on the influence of digital technology. The second approach uses the design philosophy proposed by Vilém Flusser. In this case, the research comprehends the technological tools as a means of overcoming human limitation. It affects the structures of thinking and creating, marking new relations between man, knowledge, creativity and reality. In particular, incursions are established from theoretical concepts proposed by the philosopher: \"gesture of making\", \"apparatus\", \"technical image\", \"gesture of calculation and computation\", and \"the program\". These approaches raids propose dialogues with other theorists of the field of knowledge and case studies that endorse the argument. Finally, they settle critical considerations about the influence of digital technology in Architecture offering up prospects for the creation based on digital models.
8

Análise da influência das configurações dos pontos de apoio e do voo na acurácia de ortofotomosaicos elaborados a partir de dados de VANT

Souza, Gabriel de January 2018 (has links)
Recentemente, o uso dos Veículos Aéreos Não Tripulados (VANTs) surgiu como uma ferramenta para a aquisição de dados geoespaciais. Os Modelos Digitais de Elevação (MDEs), as ortoimagens e os modelos tridimensionais gerados a partir de imagens de VANT são produtos cartográficos de grande utilidade para as mais diversas aplicações. Em vista das limitações dos VANTs e da recentidade desta ferramenta, este estudo visa determinar a correlação da configuração dos pontos de apoio e dos parâmetros do voo com a acurácia de ortofotomosaicos elaborados a partir de dados de VANT. Esta pesquisa utilizou dados de três levantamentos aerofotogramétricos distintos realizados com três aeronaves diferentes e considerou parâmetros relacionados à configuração dos pontos de apoio e à execução do voo. Foram gerados 200 ortofotomosaicos e 200 MDEs. Ao todo foram feitas 4616 observações de pontos de controle. Os resultados mostraram baixa correlação linear entre acurácia planimétrica e altimétrica. Os melhores resultados foram obtidos de forma inversa às alturas de voo. No geral, sob as condições de processamento utilizadas neste trabalho, recomenda-se o uso de 4 a 5 pontos de apoio por km², além do uso de voo cruzado. / Recently, the use of Unmanned Aerial Vehicle (UAV) emerged as a tool for geospatial data acquisition. Digital Elevation Models (DEMs), orthoimages and three- dimensional models generated from UAV images are cartographic products of great utility for many different applications. Considering the recency and limitations of UAV, this study aims at determining the correlation of ground control points and flight configuration with the accuracy of orthophotomosaics based on UAV data. This research used data from three different aerial surveys, performed with three different aircrafts, and considered parameters related to ground-control points distribution and to flight missions. 200 orthophotomosaics and 200 DEMs were generated and a total of 4616 ground-control points measurements were performed. Results did not show a linear correlation between planimetric and altimetric accuracy. The best correlation results were obtained inversely related to flight height. In general, under the processing conditions used in this work, we recommend the use of 4 control points per km² and a cross flight pattern.
9

Análise da influência das configurações dos pontos de apoio e do voo na acurácia de ortofotomosaicos elaborados a partir de dados de VANT

Souza, Gabriel de January 2018 (has links)
Recentemente, o uso dos Veículos Aéreos Não Tripulados (VANTs) surgiu como uma ferramenta para a aquisição de dados geoespaciais. Os Modelos Digitais de Elevação (MDEs), as ortoimagens e os modelos tridimensionais gerados a partir de imagens de VANT são produtos cartográficos de grande utilidade para as mais diversas aplicações. Em vista das limitações dos VANTs e da recentidade desta ferramenta, este estudo visa determinar a correlação da configuração dos pontos de apoio e dos parâmetros do voo com a acurácia de ortofotomosaicos elaborados a partir de dados de VANT. Esta pesquisa utilizou dados de três levantamentos aerofotogramétricos distintos realizados com três aeronaves diferentes e considerou parâmetros relacionados à configuração dos pontos de apoio e à execução do voo. Foram gerados 200 ortofotomosaicos e 200 MDEs. Ao todo foram feitas 4616 observações de pontos de controle. Os resultados mostraram baixa correlação linear entre acurácia planimétrica e altimétrica. Os melhores resultados foram obtidos de forma inversa às alturas de voo. No geral, sob as condições de processamento utilizadas neste trabalho, recomenda-se o uso de 4 a 5 pontos de apoio por km², além do uso de voo cruzado. / Recently, the use of Unmanned Aerial Vehicle (UAV) emerged as a tool for geospatial data acquisition. Digital Elevation Models (DEMs), orthoimages and three- dimensional models generated from UAV images are cartographic products of great utility for many different applications. Considering the recency and limitations of UAV, this study aims at determining the correlation of ground control points and flight configuration with the accuracy of orthophotomosaics based on UAV data. This research used data from three different aerial surveys, performed with three different aircrafts, and considered parameters related to ground-control points distribution and to flight missions. 200 orthophotomosaics and 200 DEMs were generated and a total of 4616 ground-control points measurements were performed. Results did not show a linear correlation between planimetric and altimetric accuracy. The best correlation results were obtained inversely related to flight height. In general, under the processing conditions used in this work, we recommend the use of 4 control points per km² and a cross flight pattern.
10

Uso da modelagem digital de terreno e de superfície para a estimativa do potencial de verticalização na região do campo de marte (SP) / Use of digital terrain and surface modeling to estimate the vertical expansion potencial in the campo de marte (SP)

Araújo, Priscila Câmara de 18 December 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Ciências Humanas, Departamento de Geografia, Programa de Pós-Graduação em Geografia, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-03-31T16:36:20Z No. of bitstreams: 1 2015_PriscilaCâmaradeAraújo.pdf: 3124057 bytes, checksum: 2b221e051c7eb29ebbdd1ca4d015077d (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-04-01T20:46:24Z (GMT) No. of bitstreams: 1 2015_PriscilaCâmaradeAraújo.pdf: 3124057 bytes, checksum: 2b221e051c7eb29ebbdd1ca4d015077d (MD5) / Made available in DSpace on 2016-04-01T20:46:24Z (GMT). No. of bitstreams: 1 2015_PriscilaCâmaradeAraújo.pdf: 3124057 bytes, checksum: 2b221e051c7eb29ebbdd1ca4d015077d (MD5) / O planejamento da ordenação territorial é imprescindível para o crescimento das cidades. Os Planos Diretores têm papel fundamental no estabelecimento de diretrizes para ocupação dos espaços. A implantação do Trem de Alta Velocidade brasileiro aumenta as possibilidades de relações entre centros urbanos e impacta a ordenação do território, especialmente as áreas de implantação das estações. Nesse sentido, a modelagem digital torna-se uma ferramenta importante no planejamento da ocupação dos terrenos, tendo em vista que os Modelos Digitais de Terreno (MDT) e os Modelos Digitais de Superfície (MDS) fornecem informações do terreno e dos elementos sobre a superfície. Para o desenvolvimento deste trabalho, foi escolhida a região do Campo de Marte (SP), uma das regiões previstas para implantação de uma estação do TAV Brasil, com o objetivo testar uma metodologia de trabalho que auxilie na estimativa das potencialidades de verticalização em torno da estação, modelando uma simulação de mudança de gabarito na área. Utilizando ortofotos e o MDS produzidos em 2010/2011, pela a Empresa Paulista de Planejamento Metropolitnao (Emplasa) e, disponibilizados pela Empresa de Planejamento e Logística (EPL) do governo federal, foi feito o mapeamento das ruas e edificações da área de influência indireta do Campo de Marte e a construção do MDT. Foi calculado o volume de ocupação atual da área pela diferença dos valores de elevação obtidos pelo MDS e MDT para dentro da área da estrutura predial multiplicado pela área desta estrutura. Os resultados obtidos foram a classificação das edificações atuais e a verificação de que a área de estudo ainda possui um grande potencial de verticalização permitido pelo plano diretor (cerca 5 milhões de metros cúbicos). / The growth of cities is dynamic and constant and is essential to planning the territorial ordination. The Directive Plans play a fundamental role in the establishment of guidelines and strategies for the space occupation. The implementation of the brazilian High Speed Train increase the chance of relations between urban centers and impacts land use planning. In this sense, digital modeling becomes an important tool in planning the occupation of the land, given that the Digital Terrain Models (DTM) and the Surface Digital Models (MDS) provide the land information and evidence on the surface .To develop this work, it was chosen the region of Campo de Marte (SP), one of the areas provided for implementation of a station TAV Brazil, aiming to predict the potential for occupation around the station. Using orthophotos and MDS produced in 2010/2011 by the Paulista Company of Metropolitan Planning (Emplasa) and made available by the federal government Company for Planning and Logistics (EPL), has done the mapping of streets and buildings in the area of indirect influence of the Campo de Marte and the construction of the MDT. We calculated the volume of the current occupation of the area by the difference in elevation values obtained by MDS and MDT and into the area of the building structure multiplied by the area of this structure. The results were the classification of current buildings and verification that the study area still has great potential for vertical expansion allowed by the directiver plan (about 5 million cubic meters), and when simulated (to a height of 87 meters) the triples value.

Page generated in 0.0833 seconds