• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 166
  • Tagged with
  • 167
  • 163
  • 153
  • 144
  • 129
  • 38
  • 36
  • 35
  • 35
  • 31
  • 30
  • 28
  • 28
  • 25
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estruturas pré-moldadas de concreto para edifícios de múltiplos pavimentos de pequena altura: uma análise crítica / Precast concrete structures for multi-storey and low height buildings: a critical analysis

Marcos Neto, Noé 06 February 1998 (has links)
Este trabalho apresenta uma abordagem generalista das estruturas pré-moldadas de concreto nos edifícios de pequena altura (até 12 m), excluídos os galpões. É analisada a questão da qualidade na produção dessas estruturas sob as recomendações da série ISO 9000. São analisados os tópicos mais relevantes para a elaboração dos projetos dessas estruturas. Um estudo de caso escolhido ilustra as peculiaridades no desenvolvimento do projeto de estrutura pré-moldada nesta categoria. As conclusões obtidas retratam a quebra de alguns paradigmas brasileiros para o emprego das estruturas pré-moldadas: a) A qualidade das estruturas de concreto pode ser controlada por um sistema de gestão da qualidade internacionalmente reconhecido e empregado nos mais diferentes processos de produção de bens e serviços. b) Os índices técnico-econômicos evidenciam que mesmo em uma estrutura com característica não modular e pequena área construída pode ser empregado o concreto pré-moldado. / This work presents a general focus on precast concrete structures for low height buildings (up to 12 meters) not including storage sheds. The work is an analysis of the question of production quality of such structures according to the recommendation of the serie \'ISO 9000\'. Also, the most relevant topics for the elaboration of the projects for the focused strutures are analysed. A study of a chosen case illustrates the peculiarity of the development of the project for the precast struture for the chosen category of buildings. The final conclusion of the study demonstrates a break for the brazilian paradigma on the use of the precast concrete structures: a) The quality of the precast concrete structures can be controlled by the same quality control system widely known worldwide and used for controlling quality of production of a wide range of products and services as well. b) The technical-economics rates are shown with sharp evidence that even a small and non-modular precast structure within a small construction area can be object of precast concrete.
12

Estudo experimental de consolos de concreto com fibras moldados em etapas distintas dos pilares / Experimental research of reinforced fiber concrete corbels shaped in distinct stage to the column

Costa, Jônatas Barreto de Andrade 15 May 2009 (has links)
A produção industrial do consolo tradicional apresenta dificuldades devido à grande quantidade de armadura em um espaço pequeno. Além da armadura do tirante principal, normalmente se utilizam estribos verticais e horizontais. O presente estudo experimental propõe um consolo moldado em etapa anterior à do pilar, com a armadura e superfícies preparadas para a ligação posterior com o pilar, durante a concretagem deste elemento. O consolo dispõe somente da armadura do tirante principal e de fibras metálicas incorporadas à matriz de concreto, sem estribos verticais ou horizontais. Em alguns modelos foi utilizado um tipo de armadura de costura alternativo. As principais variáveis analisadas foram a taxa de armadura e o arranjo das barras dos tirantes. A adição de fibras ao consolo reduziu a fissuração na biela de compressão e aumentou a resistência à ruptura dos consolos em 8%, apresentando boa ductilidade, mesmo depois da máxima solicitação. Com o aumento da armadura do tirante no consolo com fibras, a resistência à ruptura foi 69% maior. Considerando o patamar de solicitação de serviço do consolo tradicional, os modelos moldados em etapas distintas apresentaram aberturas de fissuras na interface consolo-pilar 33% maiores, apesar de demorarem mais a aparecer. Entretanto, quando aumentada a taxa de armadura principal, os modelos moldados em etapas distintas demonstraram fissuras 23% menores que o consolo tradicional. / The industrial production of traditional corbel presents some difficulties due to the great quantity of reinforcement in a small space. Beyond the main bars, it is generally used vertical and horizontal stirrups. This experimental study proposes a corbel shaped in the prior stage to the column, with the reinforcement and surfaces prepared to the later connection with the column during the molding of it. The corbel has only the reinforcement of main bars and steel fibers incorporated to the concrete matrix, without vertical or horizontal stirrups. In some models were used a kind of alternative secondary reinforcement. The main variables analyzed were the reinforcement rate and the arrangement of the main bars. The addition of fibers to the corbel reduced the crack in the compressed diagonal and increased the resistance to rupture of corbels in 8%, presenting a reasonable ductility even after the maximum load. With the increase of reinforcement of main bars in the corbel with fibers, the resistance to rupture was 69% greater. Considering the baseline of service load of traditional corbel, models shaped in distinct stages presented crack openings 33% larger, in spite of taking a longer time to show up. However, when the rate of primary reinforcement was increased, the models shaped in distinct stages had cracks 23% smaller than the traditional corbel.
13

Análise experimental de aduelas pré-moldadas em concreto de alto desempenho para passarelas estaiadas / Theoretical and experimental analysis of precast barrel staves in high performance concrete

Conceição, Rodrigo Vieira da 19 March 2008 (has links)
Embora a utilização do concreto de alto desempenho (CAD) para a fabricação de elementos pré-moldados seja frequentemente usado na construção civil, o presente trabalho apresenta um estudo do emprego de microconcreto em aduelas tubulares de pequenas espessuras protendidas dentro de critérios fabris, com materiais regionais, a fim de repassar para a iniciativa privada os resultados colhidos das análises já elaboradas. As aduelas servirão para compor o tabuleiro de passarelas estaiadas, com a intenção de projetar uma estrutura que, além de harmônica aos olhos e arrojada, também seja econômica, pois se aplicando a protensão nas aduelas que formam o tabuleiro, pode-se explorar uma das características que os concretos de alto desempenho e resistência têm de melhor, que é a resistência à compressão (> 80MPa). Os materiais utilizados na dosagem do microconcreto para a confecção dos elementos em escala real, foram os seguintes: CP V ARI RS, sílica de ferro-silício em substituição volumétrica ao cimento em 10%, três tipos de areias de cava da região para o melhor empacotamento das partículas reduzindo os vazios, pedrisco basáltico com dimensão máxima de 9,5 mm em consonância com as características geométricas do elemento estrutural e da armadura e um superplastificante para atingir a consistência desejada. Levaram-se em conta na produção desse trabalho os recentes desenvolvidos havidos na reologia dos concretos frescos, ação da carbonatação e ação de cloretos. A consistência do concreto foi um fator importante para a determinação do traço, pois o concreto foi lançado nos moldes a uma altura de 2,40 m, permanecendo coeso. A concretagem foi realizada através de betonadas consecutivas para o total preenchimento do molde, onde em todas as betonadas foram realizadas a mesma seqüência de mistura pré-estabelecida. Foram moldadas duas aduelas em escala real, as quais foram estudadas seguindo a simulação do processo de montagem e uso da passarela, a fim de se analisar as solicitações atuantes e as formas de ruína das aduelas acopladas. As resistências mecânicas dos corpos-de-prova foram analisadas nas idades de 1, 3, 7, 28, 63 e 91 dias, cujos resultados de resistência à compressão simples, compressão diametral e o módulo de elasticidade atingiram ao previsto no projeto. O acabamento superficial, o tempo de lançamento, adensamento, desforma, cura e o transporte foram adequados para o reaproveitamento dos moldes. Com os resultados obtidos das análises realizadas com os dois módulos do tabuleiro, verificou-se a possibilidade de construir passarelas com elementos tubulares de pequena espessura protendidos com barras de Dywidag pelo sistema de protensão proposto. Verificou-se também uma pequena amplitude das deformações e deslocamentos das aduelas no processo de montagem e uso da passarela, assim como no transporte das aduelas. Não foram observadas a formação de quaisquer tipos de fissuras durante todo o processo envolvido, quais sejam, desmoldagem, estocagem, transporte, lançamento e utilização simulada. / Although the use of high performance concrete (HPC) for precast elements manufacture is frequently used in civil construction, this work presents a study of the utilization of microconcrete in prestressed small thicknesses tubular barrel stave, in manufacturing criteria, with regional materials, in order to repass to private initiative the already elaborated analyses results. Barrel stave will serve to compose cable-stayed footbridge deck, with the intent to project a structure that, beyond pleasant and bold, must be also economic, therefore applying prestress in barrel stave to form the deck, it\'s possible to explored the most important high performance and strength concrete characteristics, the compressive strength (> 80MPa). The used materials to design a microconcrete for the elements confection in real scale, are the following: CP V ARI RS, ferrosilicon silica fume in 10% volumetric substitution to the cement, three types of regional sands for optimum particles packing to reduce the emptinesses, 9,5 mm basaltic grave in accord with the geometric characteristics of the structural element and reinforcement, and superplasticizer additives to reach the desired consistency. Recent researches about fresh concrete rheology, carbonation and chloride action had been taken in account in the production of this work. The consistency was an important factor for concrete design, therefore the concrete would be was launched in 2,40 m height molds, remaining united. The molding was carried through consecutive load concrete mixer operation for the total fulfilling of the mold, where in all load of a concrete mixer had been carried through the same sequence of pre-established mixture. Two were molded barrel stave full scale, which were studied in the simulation of process of assembly and use of footbridge in order to examine the requests engaged in the forms of ruin from barrel stave coupled. The mechanical strength of the samples had been analyzed in ages of 1, 3, 7, 28, 63 and 91 days, whose results of simple compressive strength, diametrical compression and the modulus of elasticity had reached to the foreseen in project. The superficial finishing, the time of launching, compacting, desmoulding, cure and the transport had been adjusted for molds reuse. With the results of analyses conducted with two modules of deck, there was the possibility of building footbridges with tubular elements of small thickness prestressed with bars of Dywidag the system protention proposed. There was also a small extent of deformation and displacement of barrel stave in process of assembly and use of footbridge as well as the transport of barrel stave. Not been observed the formation of any types of cracks during all the involved process, which are, desmoulding, storage, transport, launching and simulated use.
14

Influência da rugosidade superficial e o uso de novos tipos de fibras em almofadas de argamassa para ligações de concreto pré-moldado / Influence of surface roughness and the use of new types of fiber in bearing pads of cement-based material for precast concrete connections

Bellucio, Ellen Kellen 12 March 2010 (has links)
Este trabalho apresenta o estudo de uma argamassa modificada para ser utilizada como almofada de apoio em ligações entre elementos de concreto pré-moldado. Esta argamassa é composta de cimento e areia, com a adição de látex estireno-butadieno (SB), agregado leve (vermiculita) e fibras curtas (polipropileno, vidro e PVA). As pesquisas anteriores mostraram que este compósito apresentou uma boa resistência à compressão e baixo módulo de elasticidade. O objetivo desta pesquisa é dar continuidade dos estudos anteriores analisando a influência da rugosidade superficial nas almofadas, introduzida para aumentar a sua deformabilidade e testar diferentes tipos de fibras. A rugosidade é analisada comparando placas com ambos os lados lisos, um lado liso e outro rugoso e ambos os lados rugosos. Foram estudadas dois tipos de fibras de polipropileno de 10 mm de comprimento - uma com 12 \'mü\'m e outra com 180 \'mü\'m de diâmetro. Nesta pesquisa foram realizados ensaios de caracterização do compósito (compressão simples, tração por compressão diametral e módulo de elasticidade) e ensaios em placas (compressão centrada monotônica e cíclica, força concentrada e flexão). Os resultados de caracterização apontam um bom comportamento do compósito, com resistência à compressão de 41 MPa e módulo de elasticidade de 12,8 GPa. Os ensaios de placas mostram melhores resultados para fibras de 12 \'mü\'m de diâmetro em função de: a) uma redução de 30% da rigidez nos ensaios monotônicos em relação a uma argamassa de referência, b) melhor capacidade de absorção de carga no ensaio de força concentrada e c) no ensaio de flexão, um índice de tenacidade 40% maior quando comparadas com os outros traços estudados. Na análise da rugosidade superficial, o melhor resultado é com rugosidade em ambos os lados da placa, sendo que nos ensaios de carregamento monotônico e cíclico houve uma redução de até 30% na rigidez e um aumento do afundamento acumulado de mais de 120% em relação às placas com ambos os lados lisos. / This paper presents the study of a mortar modified to be used as a bearing pad connections between precast concrete elements. This mortar is composed of cement and sand, with the addition of styrene-butadiene latex (SB), lightweight aggregate (vermiculite) and short fibers (polypropylene, glass and PVA). Previous research showed that this composite presents good compressive strength and low modulus of elasticity. The objective of this research is to continue the previous studies, analyzing the influence of surface roughness on the pads, introduced to increase its deformability, and test other types of fibers. The roughness is analyzed by comparing bearing pads with both smooth sides, one side smooth and other rough and rough both sides. Two types of polypropylene fibers of 10 mm in length - one with 12 \'mü\'m and another with 180 \'mü\'m in diameter are studies. In this research, test were carry out to characterize the composite (compressive strength, tensile strength by diametral compression and modulus of elasticity) and test on bearing pads (uniform compressive load - monotonic and cyclic, concentrated load and bending). The results on cylindrical samples to characterize the composite indicate a good behavior, the compressive strength of 41 MPa and modulus of elasticity of 12.8 GPa. The test bearing pads presents the best results for fibers of 12 \'mü\'m of diameter in terms of: a) a 30% reduction of stiffness in the monotonic tests in relation to a reference mortar, b) the best ability to absorb the load test concentrated load and c) the bending test, an index of toughness 40% higher when compared with the other mixture studied. Regarding surface roughness analysis, the best result is with roughness on both sides of the bearing pads, and tests of monotonic and cyclic loading are reduced by 30% in stiffness and an increase in deformation accumulated more than 120% bearing pads regarding with both sides smooth.
15

Análise tipológica de elementos e sistemas construtivos pré-moldados de concreto do ponto de vista de sensibilidade a vibrações em serviço / Typological analysis of precast concrete elements and building systems in terms of sensitivity to vibration in service

Diógenes, Hidelbrando José Farkat 19 March 2010 (has links)
No contexto da modernização da construção civil, a aplicação de elementos estruturais de concreto pré-moldado nas construções oferece comprovados benefícios à estratégia de execução das obras, dentre os quais se destacam o atendimento a vãos relativamente grandes, rapidez de montagem, leveza e excelente qualidade dos elementos que compõem a estrutura. Tratando-se especialmente do comportamento dinâmico das estruturas de concreto, os elementos pré-moldados, por apresentarem diversas situações transitórias de solicitação, devem ser avaliados quanto aos efeitos dinâmicos decorrentes da sua produção, transporte, montagem, execução das ligações, finalização da obra e uso. Considerando, nesse contexto, que a protensão é um recurso frequentemente utilizado nos elementos, evidencia-se a necessidade de estudos sobre a sua influência nos parâmetros dinâmicos. Em particular, elementos pré-fabricados protendidos, tais como painéis tipo duplo-T e lajes alveolares, têm sido muito utilizados em pisos de edifícios, todavia e não raras vezes sem uma prévia análise dinâmica quanto à vibração e ao atendimento aos limites de vibração em serviço. O presente trabalho apresenta uma síntese dos procedimentos de cálculo e verificação indicados por normas técnicas do Brasil e do Exterior para a avaliação do conforto humano quanto a vibrações excessivas, assim como os métodos analíticos empregados na determinação da frequência natural de um elemento estrutural, seja ele protendido ou não. Efetuou-se um estudo comparativo dos resultados analíticos com os de uma simulação numérica de painéis duplo-T e lajes alveolares, feita com programa computacional ANSYS, baseado no Método dos Elementos Finitos, sendo eles discutidos quanto ao Estado Limite de Vibrações Excessivas (ELS-VE). Este trabalho apresenta também um estudo experimental sobre um modelo físico de viga de concreto protendido com cabos externos, com o objetivo de demonstrar a aplicação de técnicas de caracterização dos parâmetros dinâmicos e discutir eventuais soluções para o controle ou atenuação de vibrações excessivas. Essa viga foi também analisada numericamente com o programa computacional ANSYS e feita a comparação dos resultados experimentais e numéricos. Conclui-se que, do ponto de vista do ELS-VE, os painéis duplo-T e lajes alveolares particularmente analisados são passíveis de restrições a partir de certos vãos e que, sob determinadas condições ora discutidas, o emprego de tirantes externos, protendidos ou não, podem ser aplicados no controle de vibrações, seja por aumento da rigidez do sistema viga-tirante, seja pelo controle da fissuração do concreto. / In the context of construction modernization, the application of precast concrete elements offers a good and reliable alternative in the construction strategy, among them large spans, fast assembly, lightweightness and excellent structural members quality. Dealing about dynamic behavior of concrete structures, precast elements are subjected to several loading conditions, from their manufacturing, transport, assembly, connection and finally to service. Prestressing technique is often applied in precast elements, so the influence of prestressing forces on dynamic parameters must be considered. Precast prestressed concrete elements, such as double-T panels and hollow core slabs are commonly used in building floors, but not always a previous dynamic evaluation is accomplished, so vibration problems are likely to occur. This work presents a synthesis of design procedures as recommended by the brazilian and foreign codes regarding to human comfort under vibration conditions. Analytical methods allow the determination of natural frequency of structural elements, being them prestressed or not. Also typical double-T panels and hollow core slabs were analyzed by Finite Element Method (ANSYS software) and analytical and numerical results were compared. A discussion of the results about the Service Vibration Limit State is made. This work also presents an experimental study on a reinforced concrete beam provided with external prestressing tendons. The goal of this study was to demonstrate dynamic tests to characterize dynamic parameters and to discuss vibration control. The tested beam was also simulated on ANSYS to compare theoretical and experimental results. Some conclusions has been drawn, such as typical double-T panels and hollow core slabs may suffer restrictions above certain span dimensions. Also the application of external tendons, with or without prestressing forces may be applied to reduce vibration levels, either by increasing stiffness of the structure or controlling cracking of the concrete beam.
16

Comportamento de juntas de argamassa solicitadas à compressão na ligação entre elementos pré-moldados / Compression mortar joints behavior at the precast elements connection

Barboza, Aline da Silva Ramos 28 February 2002 (has links)
Este trabalho apresenta uma análise teórico-experimental do comportamento de juntas de argamassa solicitadas à compressão, usando para preenchimento da junta materiais comercialmente disponíveis e almofada de apoio de argamassa flexível, com o objetivo de propor recomendações de projeto que caracterizem a deformabilidade e a resistência da junta, visando um melhor aproveitamento da capacidade resistente do sistema pré-moldado. Inicialmente foi feito um levantamento bibliográfico sobre os principais parâmetros que influenciam o comportamento da junta e, posteriormente, foram realizadas algumas simulações numéricas utilizando-se o programa ANSYS 5.5.1. Em seguida, desenvolveu-se um programa experimental cujas variáveis foram: a espessura da camada de argamassa, a resistência do elemento pré-moldado e da argamassa, o material de preenchimento da junta, a presença de armadura de reforço na região adjacente à ligação e a rugosidade na superfície do elemento. Os resultados obtidos mostraram que a espessura de 20mm seria a mais indicada, pois, além de minimizar o efeito de descontinuidade provocado pela presença da junta, melhora o controle da uniformidade da espessura e o aparecimento de vazios. Observou-se também que o uso de concreto de alta resistência no elemento pré-moldado faz com que as tensões de fendilhamento tenham maior importância. Para um maior aproveitamento da capacidade resistente do sistema, o material de preenchimento também deve ser de alta resistência. Dos diversos materiais usados para o preenchimento da junta, a argamassa do tipo “Dry Pack" foi a que ofereceu melhores condições de execução. Além de proporcionar total aproveitamento da capacidade resistente do sistema, diminuiu a deformabilidade da junta e, conseqüentemente, a fissuração / In this thesis a theoretical-experimental analysis of the compression mortar joints behavior is presented. The joints were produced with commercially available materials and flexible support cushion. The purpose of this research was to obtain design recommendations that characterize the deformability and the strength of the joints, in order to have a better use of the precast system bearing capacity. Previous studies of this problem showed the main parameters related to the joint behavior and numerical simulations were carried out using ANSYS 5.5.1. An experimental program was developed considering as variables the thickness of the mortar layer, the strength of the precast concrete element and of the mortar, the joint material, the additional reinforcement in the connection area and the roughness of the element surface. The results showed that a 20mm thickness is most suitable, because besides minimizing the discontinuity effects, it improves the control of the uniformity of the thickness as well as the air retained in the joint. It was also observed that using high strength concrete precast elements the splitting stresses becomes more important. For a larger use of the bearing capacity of the system, the joint material should also be of high strength. The use of a "Dry Pack" mortar offered better execution conditions, improving the bearing capacity of the system, with less deformability as well as cracking
17

Cisalhamento na interface entre concreto pré-moldado e concreto moldado no local em elementos submetidos à flexão / Shear at interface between precast and cast-in-place concrete in composite elements

Araújo, Daniel de Lima 07 July 1997 (has links)
Neste trabalho é abordado o cisalhamento pela interface entre concreto pré-moldado e concreto moldado no local em vigas e lajes compostas. São apresentados os modelos analíticos e empíricos empregados na avaliação da resistência ao cisalhamento pela interface entre duas superfícies de concreto atravessadas por armadura. Esses modelos são utilizados para avaliar a resistência ao cisalhamento pela interface de vigas compostas, disponíveis na literatura, sendo indicados os que melhor representaram os resultados experimentais. São apresentadas também as indicações das principais normas sobre o assunto e algumas indicações de detalhes construtivos para peças compostas. Na seqüência são apresentados os resultados de ensaios de cisalhamento direto e ensaios em vigas compostas realizados com o objetivo de avaliar de forma qualitativa a resistência da interface. Algumas das principais conclusões foram: a) existem divergências significativas entre os valores recomendados pelas normas; b) observou-se boa aproximação entre os modelos analíticos e alguns modelos empíricos, obtidos de ensaios de cisalhamento direto, com os resultados de ensaios de vigas compostas obtidos da literatura; c) é recomendável a inclusão de um limite máximo na expressão fornecida pela norma brasileira (NBR-9062) para avaliação da resistência da interface de peças compostas. / This work deals with the shear at interface between precast and cast-in-place concrete in composite beams and slabs. Analytical and empirical models to predict the shear strength of interface with steel cross the transversal section are showed. These models are used to predict the shear strength at interface in composite beams and are pointed the models that presented better approximation with experimental results. The main codes and some constructive details of the composite elements are showed. Push-out tests and tests in simply supported composite beams were carried on during this research and results are included in this work. Some of the main conclusions are: a) there are significant discrepancy among codes indication; b) the experimental results of composite beam showed a good agreement with the analytical models and some empirical models originate to push-out tests; c) it is recommended to define an upper limit in the expression indicated by Brazilian Code (NBR-9062) for estimation of the shear strength at interface in composite elements.
18

Pórticos em concreto pré-moldado preenchidos com alvenaria participante / Infill walls in precast concrete frames

Medeiros, Wallison January 2018 (has links)
Submitted by Wallison Medeiros (wamedeiros@hotmail.com) on 2019-01-22T10:58:45Z No. of bitstreams: 1 Medeiros_WA.pdf: 11036463 bytes, checksum: 842aff888e052eb4d2fc0aa7a42f3484 (MD5) / Approved for entry into archive by Lucas Paganine (lucaspaganine@ibict.br) on 2019-02-05T16:59:15Z (GMT) No. of bitstreams: 1 Medeiros_WA.pdf: 11036463 bytes, checksum: 842aff888e052eb4d2fc0aa7a42f3484 (MD5) / Made available in DSpace on 2019-02-05T16:59:18Z (GMT). No. of bitstreams: 1 Medeiros_WA.pdf: 11036463 bytes, checksum: 842aff888e052eb4d2fc0aa7a42f3484 (MD5) Previous issue date: 2018 / This research presents a study on the behavior of precast concrete frames with participating masonry infill to be considered in the design of a building lateral load bracing system. The study brings a literature review on the topic. An experimental testing of a reinforced concrete frame infilled or not with masonry is used to calibrate a finite element model using the Simulia Abaqus 2017 package. The model uses concrete damage plasticity to consider both the concrete and the masonry behaviour. Embedded elements are used to consider rebars inside the concrete. Masonry elements are considered homogeneous with contact surfaces along the concrete-masonry interface. After the properties were calibrated the numerical models showed excellent accuracy when compared to the experimental tests. Precast concrete frames, whose dimensions and properties were from a real case, was then modelled with and without the participating masonry frame. The column-corbel and beam connection was modelled with solid elements with contact surface on the interface allowing to close represent its behaviour. Models considered a frame with one, five and ten storeys, two masonry strength and the use or nor of a mortar layer to fix masonry under the concrete beam. Conclusion from the finite element model analyses indicate the influence of each parameter on the system behaviour. The FEM results were then used to calibrate the width of a diagonal truss to be used in simple bar element models. Finally, a 3D-frame model was used to evaluate a actual 10-story precast concrete building considering or not the participating infill masonry. Only two masonry walls, close to the building central core and without openings, were considered yet results indicate great influence on considering the participating infill leading to an efficient building design. Future work is proposed to experimentally evaluate the conclusions from the numerical analyses here reported. / O presente trabalho realizou um estudo sobre o comportamento de estruturas aporticadas em concreto pré-moldado preenchidas com painéis de alvenaria, para fim de contraventamento de edificações, considerando a contribuição dessa alvenaria de preenchimento no pórtico pré-moldado para análise de ações horizontais. O estudo traz uma revisão da literatura sobre o tema. Um ensaio experimental de um pórtico de concreto armado preenchido ou não com alvenaria é usado para calibrar um modelo de elementos finitos usando o pacote Simulia Abaqus 2017. O modelo utiliza o dano plástico do concreto (CDP) para considerar o comportamento do concreto e alvenaria. Elementos embutidos são usados para considerar armaduras dentro do concreto. Os elementos de alvenaria são considerados homogêneos com as superfícies de contato ao longo da interface concreto-alvenaria. Depois que as propriedades foram calibradas, os modelos numéricos apresentaram excelente precisão quando comparados aos testes experimentais. Os quadros de concreto pré-fabricados, cujas dimensões e propriedades eram de um caso real, foram então modelados com e sem o preenchimento de alvenaria participante. A conexão pilar-viga foi modelada com elementos sólidos com superfície de contato na interface permitindo representar seu comportamento. Os modelos considerados foram um quadro com um, cinco e dez andares, duas resistências de alvenaria e o uso ou não de uma camada de argamassa para fixar alvenaria sob a viga de concreto. A conclusão das análises do modelo de elementos finitos indica a influência de cada parâmetro no comportamento do sistema. Os resultados de MEF foram utilizados para calibrar a largura de uma diagonal equivalente para ser usado em modelos simples de elementos de barras. Finalmente, um modelo de pórticos em 3D foi usado para avaliar um prédio de concreto pré-moldado de 10 andares, considerando ou não a alvenaria participante. Apenas duas paredes de alvenaria, perto do núcleo central do edifício e sem aberturas foram consideradas, os resultados indicam grande influência ao considerar o preenchimento participante, levando a um projeto de construção eficiente. O trabalho futuro é proposto para avaliar experimentalmente as conclusões das análises numéricas aqui relatadas.
19

Investigação de compósitos cimentícios para preenchimento de juntas da interface e de nichos em ligações de estruturas pré- moldadas

Bertolucci, Felipe Sakae [UNESP] 12 April 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-04-12Bitstream added on 2014-06-13T20:27:39Z : No. of bitstreams: 1 bertolucci_fs_me_ilha.pdf: 2860301 bytes, checksum: 3f3004f9d02861054ffe5fb10b1b2e7d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A indústria estruturas de concretos pré-moldados possui como grande preocupação a ligação entre seus elementos, tendo em vista que a mesma exerce grande influência no comportamento da estrutura, sendo responsável pela transmissão e redistribuição dos esforços na estrutura. A grande diferença entre estruturas pré-moldadas e estruturas de concreto moldadas “in loco” em relação ao seu comportamento estrutural está na ligação entre seus elementos. As ligações apresentam certa deformação quando solicitadas, recebendo na literatura técnica a denominação de ligações semi-rígidas. Dessa forma, buscou-se estudar todos os grautes existentes no mercado e desenvolver um compósito cimentício de fácil preparo e de baixo custo, do tipo calda de cimento e argamassa, que apresentasse características mecânicas similares aos grautes. Foram desenvolvidas duas caldas de cimento e uma argamassa, as quais foram submetidas juntamente com os grautes selecionados a ensaios específicos de propriedades adesão e aderência. Dentre as principais conclusões obtidas podem ser ressaltadas que a grande parte dos grautes possui problemas de fluidez dificultando o preenchimento total das ligações e sua aplicação. Em relação à aderência as duas caldas de cimento e a argamassa apresentaram comportamento semelhante indicando que há uma boa condição de aderência e, os grautes, devido à sua grande diferença de composição, tiveram comportamentos distintos / One of the concerns of the precast concrete industry is the connection among their different types of elements, in order that they strongly influence the behavior of the structural group, being responsible for the transmission and redistribution of the efforts in the structure. Among the differences between precast structures and concrete structures shaped “in loco” we have the concern about the structural behavior of the link between its elements. The links have shown some deformation when tested, receiving in the technical literature the name of semi-rigid connections. For that the concrete’s precast structure has the behavior of a monolithic structure it’s necessary the solidarization of the connection which is made by filling the vertical and horizontal niches with the aid of the grout. In this paper, we aimed to study some grouts of the Brazilian market and, at the same time, develop a cimentitius composite of easy prepare and low cost, of the cement paste and mortar types, with similar mechanical characteristics to industrialized grouts to be used in the filling of the precast structures. It was rheologically and mechanically created and evaluated two kinds of cement grout and one mortar composition that were submitted along with the selected grouts to an evaluation of their rheological behavior, and to specific tests of their mechanical properties of adhesion and bond. This study let us conclude that the cement paste and mortar developed showed a similar rheological behavior to the Herschel-Bulkley, besides to a good condition of bond and a good behavior in the structure link when compared to some industrialized grouts. Not all the evaluated grouts showed appropriate behaviors for joints’ filling
20

Desenvolvimento de painel pré-fabricado em alvenaria protendida

Souza, Paulo Roberto Amaral 08 July 2008 (has links)
Made available in DSpace on 2016-06-02T20:09:09Z (GMT). No. of bitstreams: 1 2001.pdf: 2922784 bytes, checksum: 733f0417cb530d3dc39edf889ecdab76 (MD5) Previous issue date: 2008-07-08 / This research aims the development of a clay block post-tensioned masonry façade panels, as a new alternative building process. This process provides technical and economic advantages when compared to other process in the market. It presented an analysis of the design of the wall and the process of execution of this type of panels for its use as spandrel panels. Initially the technology of prestressed structural masonry and the systems of precast panels façade are presented to establish the concepts and basic guidelines for the development of this research. The proposed panels building process were tested experimentally with the production of three prototypes, designed for their use as horizontal façade panels. Tests were performed in which the panels were supported at the ends with its self weight and additional mid-span load applied simulating the action of horizontal out-of-plane loading in façades. The experimental tests indicate that the post-tensioned masonry panels have excellent structural behaviour, carrying more load then those estimated in the theoretical analysis, thus proving the full viability of execution and use of this type of panel. / O objetivo do presente trabalho é realizar um estudo sobre a pré-fabricação de painéis em alvenaria protendida de blocos cerâmicos, visando desenvolver uma nova alternativa para a execução de paredes que proporcione vantagens técnica e econômica em relação aos demais tipos existentes no mercado. Desta forma efetuou-se uma análise sobre o dimensionamento e o processo de execução desta tipologia de painéis, visando o seu uso em um sistema pré-fabricado para o fechamento de fachadas de galpões. Inicialmente realizou-se uma pesquisa sobre a tecnologia da alvenaria protendida e sobre os sistemas de pré-fabricação de painéis para fachadas, visando estabelecer os conceitos e diretrizes básicas para o desenvolvimento do trabalho. Propôsse métodos para a execução dos painéis, os quais foram analisados experimentalmente com a fabricação de três protótipos, concebidos para o uso como painéis de fachada horizontais. Realizou-se ensaios nos quais os painéis foram dispostos com o plano principal na posição horizontal, apoiados nas extremidades, suportando o peso próprio e cargas aplicadas no centro do mesmo, simulando-se assim a atuação de carregamentos horizontais em fachadas. Verificou-se nestes ensaios que os painéis em alvenaria protendida apresentam excelente comportamento estrutural, suportando carregamentos superiores àqueles determinados na análise teórica, comprovando-se assim a plena viabilidade de execução e utilização dos mesmos.

Page generated in 0.0277 seconds