Desenvolvimento de compositos com fibras de PAN oxidada para utilização em freios automotivosAmico, Sandro Campos 30 August 1996 (has links)
Orientador: Edison Bittencourt / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-21T16:48:08Z (GMT). No. of bitstreams: 1
Amico_SandroCampos_M.pdf: 4813233 bytes, checksum: 4be08ed16cea72b8f600cfe7666f19a7 (MD5)
Previous issue date: 1996 / Resumo: Durante o processo de produção da fibra de carbono (FC), a fibra de poliacrilonitrila (PAN) precursora passa por uma etapa de estabilização ou oxidação. Neste estágio, a fibra (PANox) adquire propriedades mecânicas desejáveis para fins onde um desempenho excelente não é exigido, evitando-se assim, a etapa de carbonização que eleva o custo final da fibra. Então, compósitos com fibras de PANox poderiam ser utilizados em campos onde as FC competem desfavoravelmente com materiais de menor custo, como metais e fibras minerais, em especial, o asbesto. Este mineral, apesar de suas boas propriedades, é conhecido por causar diversos males à saúde, como a asbestose. Após um estudo preliminar sobre a fibra (teor de umidade, TGA, FTIR-MIR e MEV) e a resina (DSC e TGA), buscou-se desenvolver uma metodologia de fabricação de compósitos de PAN oxidada e resina fenólica, com e sem aditivos, através do método de moldagem por compressão à quente, visando uma futura utilização como material de fricção em pastilhas de freios automotivos. Esta aplicação possui um elevado potencial econômico devido à sua alta performance quando comparados a materiais tradicionais. Os compósitos produzidos sofreram uma necessária etapa de pós-cura, evidenciada por análises de DSC, e foram ensaiados por compressão, flexão e fricção, além das análises de teor de umidade, densidade relativa e dureza. Os resultados obtidos indicaram níveis de dureza e fricção compatíveis aos de pastilhas comerciais, principalmente com o uso de aditivos. A estabilidade do coeficiente de fricção, porém, foi apenas regular, pois apresentou uma influência significativa da temperatura. A melhor performance foi obtida quando se utilizou cargas metálicas em combinação com cerâmicas. A metodologia empregada neste trabalho mostrou-se adequada na produção de compósitos por moldagem por compressão à quente, obtendo-se um aumento na regularidade das propriedades no decorrer dos experimentos / Abstract: During the production process of the carbon fibre, the precursor polyacrylonitrile fibre (PAN) passes by a necessary step of stabilisation or oxidation. In this stage, the fibre (PANox) has already achieved a determined levei of mechanical properties adequate to applications which do not require an excellent performance, therefore, the carbonisation step, which raises the fibre cost, is avoided. Thus, PANox composites could be used when carbon fibres compete in disadvantage with lower cost material, such as metals and mineral fibres, specially, asbestos. Although this mineral shows good properties, it is known to be harmful and might causes diseases as asbestosis. After a preliminary study about the fibre (moisture content, TGA, FTIR-MIR e SEM) and the resin (DSC and TGA), a methodology for the fabrication of oxPAN and phenolic resins composites, with and without additives, was developed by hot compression moulding. These materials are intended to be used as friction materials for automotive brake pads. This application has deserved a great attention due to its economical potentiality and high performance when compared to traditional materials. The composites passed by a necessary step of post-curing, as proved by DSC analysis, and were analysed by compression, flexural and friction tests, and water content, relative density and hardness measurements. The results for composites with fillers indicated hardness and friction levels comparable to pads in use nowadays, decreasing the great influence of the temperature on the stability of the friction coefficient. The best performance was obtained when metallic and ceramic fillers were combined. The methodology followed in this work was adequate for producing composites by hot compression moulding, achieving an increase in the regularity of the properties during the experiments / Mestrado / Mestre em Engenharia Química
|
92 |
Influencia da reutilização do hidrocoloide reversivel na alteração dimensional linear de modelos de revestimento utilizados no processo de fundição de proteses parciais removiveisArana, Andre Roberto Setten 04 December 2000 (has links)
Orientador: Celia Marisa Rizzatti-Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T13:33:14Z (GMT). No. of bitstreams: 1
Arana_AndreRobertoSetten_D.pdf: 3165588 bytes, checksum: 8d2c0adb758f1b78f8d140e623a59e5a (MD5)
Previous issue date: 2000 / Resumo: O objetivo deste trabalho foi avaliar a alteração dimensional linear de modelos revestimentos obtidos após vários ciclos de reutilização do hidrocolóide reversível (Duplitarc 50 MX - Citarc tecnologia de minérios). O modelo metálico utilizado tinha 4 marcações, A, B, C e O, dispostas nas regiões de molares e caninos em ambos os lados da arcada, de forma que quando unidas formassem a figura de um polígono irregular e permitissem a mensuração linear das distâncias AB, BC, CO, DA, AC e BO. A partir deste modelo metálico, foram confeccionados 10 modelos de gesso especial, duplicados sempre com o mesmo HR fundido em fomo de microondas. A 57.C o material era vertido sobre o modelo de gesso, e após sua geleificação, o molde era preenchido com revestimento de silicato de etila. Após a geleificação dos modelos de silicato de etila, estes eram desidratados a 180. - 200.C por 30 minutos e imersos no banho de cera de carnaúba liquefeita. Com esta metodologia foram confeccionadas 10 amostras para cada grupo estudado (G1, G2, G3, G4 e G5), após respectivamente 1, 5, 10, 15 e 20 reciclagens de fluidificação-geleificação. Foi utilizado um microscópio mensurador linear (Ernst Leitz Wetzlar - 3: 1 - Germany), para que as avaliações fossem realizadas. Após a coleta dos dados, os mesmos foram analisados pelo teste de OUNNETT'S, ao nível de 5% de significância. Os resultados mostraram que as distâncias que diferiram foram SC e CD, apenas entre os grupos G5 e G1, respectivamente com 0,0969 mm e 0,0914 milímetros de diferença entre suas médias. Os resultados permitiram concluir que mesmo apresentando diferenças estatísticas após 20 ciclos, estas foram irrelevantes laboratorialmente para o fim que o hidrocolóide é proposto, não havendo após 20 ciclos de reutilização, grandes alterações dimensionais / Abstract: One of the critical steps for the making of removable partial prostheses (RPP), it is the duplication of the work model in coating model by means of the reversible hydrocolloid. The objective of this work was evaluate lineal dimensional alteration of refractory models obtained after several cycles of heating of reversible hydrocolloid. Starting from a metallic model with points defined for lineal mensuration, were made 10 models of special gypsum, always duplicated with same reversible hydrocolloid melted in microwave's oven. At the 52°C the material was fIowed on the model of gypsum, and after its geleification, the mold was filled with coating of ethyla silicate. After the crystallization of the models of ethyla silicate, these were dehydrated at 180 - 2000C for 30 minutes and immerged in the bathing of liquefied wax. With this methodology were made samples of the 5 groups (G1, G2, G3, G4 and G5), afier respectively 1, 5, 10, 15 and 20 fluidification-geleification cycles. It was used a compared microscope lineal so that the mensurations were made. After the collection of the data the same ones were analyzed by the DUNNETT'S test with the significance leveI set on 5%. The results showed that just the distances SC with 0.0969 mm and CD with 0.0914 mm of difference between the averages respectively, presented differences statistical/y significant, only when compared between G5 (20 cycles reused) and G1 (1 cycle reused) for SC and CD respectively. The results allowed to conclude that reversible hydrocolloid recast in microwave¿s oven did not promote abrupt dimensional alterations where the samples presented dimensional stability after 20 cycles reused. / Doutorado / Protese Dental / Doutor em Clínica Odontológica
|
93 |
Análise da precisão de uma nova moldeira para implantes dentários / Accuracy of a new impression tray for dental implantsJuliana Marotti 12 November 2012 (has links)
Considerando as dificuldades envolvidas no processo de moldagem com a moldeira aberta convencional, objetivou-se neste estudo avaliar a precisão da moldagem de transferência de implantes dentais utilizando uma nova moldeira, desenvolvida com o objetivo de facilitar a técnica de moldagem. Foi confeccionado um modelo de referência de uma mandíbula edentada e instalados quatro implantes nas regiões dos elementos 44, 42, 32 e 34, denominados implantes 1, 2, 3 e 4, respectivamente. Sobre este modelo confeccionou-se uma barra de Cr-Co, para análise do desajuste. Foram realizadas 10 moldagens com silicona de adição para cada grupo (controle, moldeira aberta convencional) e teste (nova moldeira, Miratray Implant!) do modelo de referência, e após obtenção do modelo em gesso, a barra metálica foi parafusada somente no implante 1, e medida a fenda gerada na face vestibular dos implantes 3 e 4 por meio de microscópio óptico com aumento de 16x. As imagens foram analisadas por um único operador no tempo inicial e após uma semana por meio do software ImageLab. Os grupos foram comparados pelo teste de Mann-Whitney e Wilcoxon, com nível de significância estabelecido em 5%, pelo software estatístico SPSS. Os resultados mostraram diferença estatística (p = 0,04) ao comparar a média da primeira repetição do implante 3 (teste x controle); ao comparar a primeira repetição com a segunda para o implante 4 apenas no grupo controle; e na comparação dos valores máximos entre os implantes 3 e 4 do grupo controle. Em relação aos valores máximos do implante 3, obteve-se a média de 116 ± 45 m para o grupo controle, e 158 ±17 m para o grupo teste. Já para o implante 4, obteve-se a média de 106 ± 46 m para o grupo controle e 156 ± 22 m para o grupo teste. Considerando que o máximo desajuste permitido seria de 150 m, apenas o grupo controle teria um desajuste considerado aceitável clinicamente para o implante 3, entretanto sem diferença estatística para o implante 4. Como os valores dos grupos teste e controle foram muito próximos, dentro das limitações deste estudo pode-se concluir que a nova moldeira promove uma precisão do sistema barra/implante muito próxima à moldeira aberta convencional. / Considering the difficulties involved in the impression taking process when using the conventional open impression tray, the aim of this study was to evaluate the accuracy of transfer impression of dental implants using a new impression tray developed with the object of facilitating the impression-taking technique. A reference model of an edentulous mandible was fabricated, and four implants were placed in the regions of teeth 44, 42, 32 and 34, denominated implants 1, 2, 3 and 4, respectively. To analyze misfit, a Cr-Co bar was fabricated on this model. Ten impressions were taken with polyvinyl siloxane for each group (control, conventional open impression tray) and test (new impression tray, Miratray Implant!) from the reference model. After obtaining the plaster model, a metal bar was screw-retained on implant 1 only, and the gap generated at the vestibular face of implants 3 and 4 was measured by optical microcopy at 16x magnification. A single operator analyzed the images at the initial time and after one week, using ImageLab software. Groups were compared by the Mann-Whitney and Wilcoxon tests, with level of significance established at 5%, using statistical SPSS software. The results showed statistical difference (p = 0.04) when the mean of the first repetition of implant 3 (test x control) was compared; when the first repetition was compared with the second, for implant 4 only in control group; and in comparison of the maximum values between implants 3 and 4 of control group. As regards maximum values of implant 3, a mean of 116 ± 45 m was obtained for control group, and 158 ±17 m for test group. Whereas, for implant 4, a mean of 106 ± 46 m was obtained for control group and 156 ± 22 m for test group. Considering that the maximum misfit permitted would be 150 m, only control group would have a misfit considered clinically acceptable for implant 3, however, without statistical difference for implant 4. As the test and control group values were very close, within the limitations of this study, it could be concluded that the new impression tray promotes bar/implant system accuracy very close to that of the conventional open impression tray.
|
94 |
Influência de técnicas e materiais de moldagem, tempos e materiais de vazamento na exatidão tridimensional de modelos /Messias, Aion Mangino. January 2019 (has links)
Orientador: José Maurício dos Santos Nunes Reis / Resumo: Este estudo analisou a exatidão de modelos totais de gesso, obtidos a partir de diferentes técnicas e materiais de moldagem, tempos e materiais de vazamento, levando em consideração as mensurações de área, volume e angulação nos eixos X, Y e Z de pontos de referência específicos em modelo mestre (baseline), moldes e, por posteriormente, em modelos de gesso de cada condição experimental. Foi utilizado um modelo mestre com preparos nos dentes 14, 16, 21 e 25, com demarcações pontuais em suas superfícies oclusais, que funcionavam como pontos de referência. Realizaram-se três técnicas de moldagem: (T1) mistura simultânea, (T2) reembasamento - alívio com filme de PVC e (T3) moldagem digital (escâner intra-oral) - Cerec Conect Omnicam (Sirona). Para cada técnica de moldagem/tempo de vazamento foram obtidos 8 moldes totais, por único operador calibrado (ICC=0,99), com moldeira metálica de estoque e silicone de condensação (Speedex; Coltène/Whaledent Inc.) ou adição (Express XT; 3M ESPE). Os vazamentos foram realizados com gessos tipo IV convencional (GC Fuji Rock EP - GC America) e de expansão nula (Zero Stone - Dentona AG). Nos moldes com silicone de condensação o gesso foi vazado após 30 minutos, 3 ou 7 dias. Nos moldes em silicone de adição os modelos foram obtidos após 2 horas, 3, 7 ou 15 dias. Para a análise tridimensional, utilizou-se software para gerenciamento de imagens e análise das malhas tridimensionais (Rhinoceros - versão 5.3.2) obtidas com escâner óptico de bancada (R... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study analyzed the accuracy of total gypsum casts obtained from different casting techniques and materials, casting times and materials, taking into account the measurements of area, volume and angulation in the X, Y and Z axes of reference points specific master model (baseline), in the impression and, later, in the gypsum casts of each experimental condition. A master model was used with teeth 14, 16, 21 and 25, with punctual demarcations on its occlusal surfaces, which functioned as reference points. Three impression techniques were performed: (T1) simultaneous mixing, (T2) relining-relief with PVC film and (T3) chairside digital impression - Cerec Conect Omnicam (Sirona). For each impression technique / casting time, 8 total impression were obtained by single calibrated operator (ICC = 0.99), with metal stock tray and condensation silicone (Speedex; Coltène / Whaledent Inc.) or addition (Express XT 3M ESPE). The gypsum casts pouring process were performed with type IV conventional gypsum (GC Fuji Rock EP - GC America) and zero expansion one (Zero Stone - Dentona AG). For impressions with condensation silicone the cast was poured after 30 minutes, 3 or 7 days. For the addition silicone impressions, the gypsum casts were obtained after 2 hours, 3, 7 or 15 days. For the three-dimensional analysis, a software was used to manage threedimensional images (Rhinoceros - version 5.3.2) allowing the investigation of virtual images (three-dimensional meshes) made with an optical... (Complete abstract click electronic access below) / Doutor
|
95 |
Influência do resfriamento na qualidade de peças termoplásticas moldadas por injeção, com estudo de caso em sistemas CAE /Mylla, Albert Yuri Farias January 1998 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-17T06:47:28Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-09T00:24:18Z : No. of bitstreams: 1
138090.pdf: 26550921 bytes, checksum: d14a1a73300f553e20a37b47c787e090 (MD5)
|
96 |
Avaliação da desadaptação marginal de estruturas metálicas obtidas com variações quanto aos tipos de cera e às técnicas de inclusão e fundiçãoMarchiori, André Vinícius [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0
Previous issue date: 2004Bitstream added on 2014-06-13T20:18:36Z : No. of bitstreams: 1
marchiori_av_me_araca.pdf: 946522 bytes, checksum: ed4cd9e55e14d7d9431de58e44b8da02 (MD5) / Cng Solucoes Proteticas / Talladium do Brasil / O objetivo deste trabalho foi observar o comportamento de ceras para fundições, utilizando a técnica de fundição convencional, comparando-a a técnica de fundição rápida; utilizando em ambas a expansão higroscópica de um revestimento fosfatado (All Therm, CNG Soluções Protéticas). Utilizamos duas ceras: Cera para imersão GALILEO Dip Pot Wax (Talladium Inc.) e Cera Azul para fresagem (CNG Soluções Protéticas), que foram submetidas às duas técnicas de fundição propostas. Cada grupo experimental foi composto por 12 corpos de prova e, a verificação do desajuste marginal foi realizada através de um microscópio comparador digital Mitutoyo. Cada corpo de prova foi medido em quatro pontos pré-determinados no troquel metálico. A análise dos resultados demonstrou que, com a metodologia empregada, a técnica de fundição rápida apresentou desempenho favorável, quando comparado com a técnica convencional para ambas as ceras; e a cera Azul para fresagem, na técnica rápida, foi a que apresentou menor valor médio de desadaptação (sub-adaptação). Concluímos que utilizar a expansão higroscópica do revestimento fosfatado foi uma forma de viabilizar a técnica de fundição rápida, obtendo resultados favoráveis com ambas as ceras. / The purpose of this investigation was to observe and evaluate the behavior of dental casting wax in conventional and accelerated casting techniques, both using hygroscopic expansion of phosphate bonded investment, in order to determine which material or technique would provide better results about cervical fitting in the obtained metallic structure. The two casting waxes used, GALILEO Dip Pot Wax (Talladium Inc.) and Blue Wax of milling (CNG Soluções Protéticas), were submitted to both proposed casting techniques. Each experimental group was consisted of twelve specimens and, the assessment of marginal fitting was performed by means of a Mitutoyo comparator microscope. Each specimen was measured by using four pre-established points in stainless steel master die as references. From the employed methodology the analysis of the results showed that accelerated casting technique presented superior fitting in comparison with the conventional technique for both types of waxes. Besides, in the accelerated casting technique the Blue Wax of milling presented smaller mean value of unadaptation (underadaptation). We conclude that the use of the hygroscopic expansion of phosphate bonded investment was a way to viable the accelerated casting technique, obtaining favorable results with both casting waxes.
|
97 |
Sistema computacional de apoio ao projeto de componentes de plástico injetados, via internetSantana, Ricardo Rogério de January 2001 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica / Made available in DSpace on 2012-10-19T04:33:01Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T00:38:00Z : No. of bitstreams: 1
183202.pdf: 23515987 bytes, checksum: d73f64f5a77f21d68cd681610e4c6ccc (MD5) / Discussão das áreas multidisciplinares envolvidas com o projeto de componentes injetados e metodologias de projeto. Levantamento de características desejáveis para um software de apoio ao projeto, bem como análise de softwares comerciais para esta área. Proposição de um modelo de sistema computacional. Descrição de um protótipo desenvolvido e exemplos de aplicação.
|
98 |
Influência de técnicas de moldagem com e sem casquetes na exatidão dimensional de modelos de gesso e adaptação marginal de infraestruturas em zircônia /Silva, Stephania Caroline Rodolfo. January 2016 (has links)
Orientador: José Maurício dos Santos Nunes Reis / Resumo: O presente estudo analisou a exatidão de modelos de gesso, obtidos a partir de diferentes técnicas de moldagem, incluindo casquetes individuais, isolados ou unidos, bem como mensurou o desajuste marginal cervical de infraestruturas de zircônia sobre preparos dentais para coroa total. Foi utilizado um modelo mestre (controle), com preparos nos dentes 14, 16, 21 e 25, sobre o qual infraestruturas de zircônia foram confeccionadas por tecnologia CAD/CAM. Para cada técnica de moldagem: simultânea com silicone de condensação (T1a), ou adição (T1b); casquetes individuais isolados (T2); unidos com cilindros de resina acrílica (T3); unidos com cilindros metálicos (T4); foram obtidos 8 moldes totais, por único operador calibrado, com moldeira de estoque. As moldagens com casquetes foram realizadas com poliéter e as transferências com silicone de condensação. Para a análise da adaptação marginal cervical das infraestruturas de zircônia, as mesmas foram passivamente adaptadas sobre os preparos nos modelos de gesso, sendo as mensurações do desajuste marginal cervical realizadas em estereomicroscópio (50x). Para a análise de exatidão dimensional linear oclusal global, os modelos foram escaneados e, a partir de três pontos pré-definidos, realizadas mensurações látero-laterais (LL) e anteroposteriores (AP) bilaterais do arco dental no programa ImageJ. Além disso, mensurações das dimensões áxio-cervicais de cada preparo e da distância entre os preparos do segmento 14-16 foram realizadas com p... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study examined the accuracy of gypsum casts obtained from different impression techniques, including individual acrylic copings, and measured the cervical misfit of zirconia frameworks on dental preparations for fixed prosthodontics. A master cast with preparations in the teeth #14, 16, 21 and 25, on which zirconia frameworks were made by CAD/CAM technology, was used as control (baseline measurements). For each impression technique: single-step with condensation silicone (T1a), or vinyl polysiloxane (T1b); individual acrylic copings (T2); acrylic copings bonded with acrylic resin cylinders (T3) or metal cylinders (T4), 8 impressions were obtained by a single calibrated operator using stock trays. For the techniques T2, T3 and T4, polyether was used into the acrylic copings and condensation silicone was used for their pick-up. For the analysis of cervical marginal fit, zirconia frameworks were passively seated on the dental preparations of the gypsum casts, and measurements of cervical misfit calculated in stereo (50x). For the analysis of occlusal linear dimensional accuracy, the casts were scanned and, from three pre-defined points, side-to-side (LL) and bilateral anteroposterior (AP) measurements were performed by means of digitized images in the ImageJ software. Additionally, measurements of axio-cervical dimensions of each dental preparation and the distance between the preparations of the #14-16 fixed prosthodontics' segment were taken with a digital caliper. Statis... (Complete abstract click electronic access below) / Mestre
|
99 |
Efeito da radiação gama na blenda de polipropileno e polietileno destinada à produção de artigos obtidos por processo de termoformagem, moldagem por injeção e moldagem por soproRuiz, Francisco Carlos 10 August 2009 (has links)
Made available in DSpace on 2016-03-15T19:36:59Z (GMT). No. of bitstreams: 1
Francisco Carlos Ruiz.pdf: 2509048 bytes, checksum: 1e7d358e13bab2edb050547a42da7ae1 (MD5)
Previous issue date: 2009-08-10 / Fundo Mackenzie de Pesquisa / The effect of the incorporating 20% of polyethylene with 80% of polypropylene was investigated. The main objective was to study the mechanical behavior of these blends when submitted to different doses of radiation between 25 and 500kGy, in the presence of oxygen and also facing the influence of time. Sample tests were obtained by injection molding using pure polypropylene and two different kinds of polyethylene in each blend: linear low density polyethylene and high density polyethylene. In the mechanical tests it was evaluated the resistance to the Izod impact, flexural modulus, tension resistance and deformations. Analyses of differential scanning calorimetry, infrared spectroscopy and nuclear magnetic resonance were used to help in the understanding the generation of reactive species in the polymers. Although all the samples presented the same tendency in each essay,
significant differences were visualized in the resistance to the Izod impact, where the blends presented a less accentuated lose of this mechanical property, 25% in 26kGy dose of radiation, than the pure polypropylene, which lost 65% in the same dose. The behavior of stiffness for all of the samples was very similar, indicating an increase of the crystalline
domain that was also verified by thermal analyses and by an increase in the yield stress during the stress-strain test. In the stress of rupture visualizes itself the crosslinking effect of the molecular chains mainly at highest doses of radiation, 200 and 500kGy. This result was also verified by nuclear magnetic resonance analysis which indicated a reduction in the molecular mobility of the linear low density polyethylene blends. Those results showed that both blends presented a better behavior facing the ionizing radiations than the pure polymer, having practical application in the polymers transformation industry. / O efeito da incorporação de 20% de polietileno com 80% de polipropileno foi investigado com o objetivo de estudar o comportamento mecânico da blenda quando submetida à diferentes doses de radiação gama, entre 25 e 500kGy, na presença de oxigênio e também seu efeito frente ao tempo de estocagem do material ao abrigo da luz. Corpos de prova foram obtidos via moldagem por injeção utilizando polipropileno puro e dois tipos de polietileno em cada blenda: polietileno linear de baixa densidade e polietileno de alta densidade, sendo avaliada a resistência ao impacto Izod, módulo de flexão e tensões e deformações no ensaio de tração. Análises de calorimetria exploratória diferencial, espectroscopia na região do infravermelho e ressonância magnética nuclear foram utilizadas para contribuir no entendimento do processo de geração de espécies reativas nos polímeros. Muito embora todas as amostras apresentaram a mesma tendência de comportamento em cada ensaio, diferenças significativas foram visualizadas na resistência ao impacto Izod, onde as
blendas mostraram degeneração menos acentuada, 25% em dose de radiação de 26kGy, do que o polipropileno puro que perdeu 65% dessa propriedade em 26kGy. O comportamento de rigidez para todos os materiais foi muito semelhante, indicando um aumento de cristalinidade que foi comprovado pelas análises de calor de fusão e aumento na tensão no escoamento durante o teste de tração. Na tensão na ruptura visualiza-se o efeito da reticulação das cadeias moleculares principalmente nas maiores doses de radiação gama, 200 e 500kGy, também comprovado pela análise de ressonância magnética nuclear indicando uma menor mobilidade molecular alcançanda pela blenda com polietileno linear de baixa densidade. Com esses resultados alcançados, as blendas apresentam um melhor comportamento frente à radiação
ionizante do que o polímero puro, tendo aplicações práticas na indústria de transformação de polímeros.
|
100 |
Obtenção e caracterização de compósitos termoplásticos avançados à base de matrizes de poli(propileno) reforçadas com fibra de carbono.Clara Leal Nogueira 00 December 2004 (has links)
Este trabalho trata da obtenção e caracterização de compósitos de tecido de fibras de carbono de trama simples 1x1 (Plain Weave) impregnados com quatro tipos de matrizes poliméricas termoplásticas: poli(propileno) isotático (PP), copolímero de poli(propileno)-poli(etileno) (PP/PE), copolímero PP/PE com o agente de acoplamento AM1 e copolímero PP/PE com agente elastomérico AM2. As matrizes poliméricas foram caracterizadas pelas técnicas de calorimetria exploratória diferencial (DSC), termogravimetria (TG), análise térmica dinâmico-mecânica (DMTA), reologia, absorção no infravermelho com transformada de Fourier (FTIR), microscopia óptica com estágio de aquecimento e difração de raios X. Os resultados obtidos nestas análises foram correlacionados e apoiaram a proposição de um ciclo térmico de processamento dos laminados por moldagem por compressão a quente. Os laminados são formados por quinze camadas de tecido de fibra de carbono 0o/90o . As quatro famílias de laminados processadas foram avaliadas por ultra-som mostrando que a consolidação das amostras não resultou em falhas de compactação. A determinação do teor de FC nos laminados, cerca de 60% (v/v), e as análises microestruturais por microscopia óptica de luz polarizada (MOLP) e microscopia eletrônica de varredura (MEV) confirmam o adequado estabelecimento dos parâmetros de processamento dos laminados. Os ensaios mecânicos mostram que o laminado FC-PP/PE-AM1 apresenta valores mais baixos de resistência ao impacto e mais altos de resistência à tração. As análises por MEV destas amostras fraturadas por impacto e por tração revelam uma boa adesão na interface entre fibra-matriz, atribuída ao agente AM1 que melhorou a interface reforço-matriz. Os laminados FC-PP/PE-AM2 apresentam valores mais baixos de resistência à tração e mais altos de impacto, indicando que o aditivo AM2 tenacificou a matriz. Os laminados de PP-PE e PP (sem modificadores na formulação) apresentam os valores mais baixos de resistência mecânica.
|