• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 308
  • 18
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 327
  • 168
  • 87
  • 83
  • 82
  • 66
  • 63
  • 58
  • 57
  • 41
  • 39
  • 33
  • 30
  • 25
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Estudo dos impactos da exploração madeireira em áreas de concessão florestal utilizando imagens orbitais / Study of selective logging impacts in forest concession sites using remotely sensing data

Pinagé, Ekena Rangel 15 August 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Florestal, 2013. / Submitted by Elna Araújo (elna@bce.unb.br) on 2013-12-09T21:30:37Z No. of bitstreams: 1 2013_EkenaRangelPinage.pdf: 2712478 bytes, checksum: 792ab43e8e062abdef4e6cf74204a037 (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2013-12-16T20:02:52Z (GMT) No. of bitstreams: 1 2013_EkenaRangelPinage.pdf: 2712478 bytes, checksum: 792ab43e8e062abdef4e6cf74204a037 (MD5) / Made available in DSpace on 2013-12-16T20:02:52Z (GMT). No. of bitstreams: 1 2013_EkenaRangelPinage.pdf: 2712478 bytes, checksum: 792ab43e8e062abdef4e6cf74204a037 (MD5) / Os recursos florestais da região amazônica têm sido largamente explorados de maneira predatória. Para reverter esse cenário, um novo modelo de gestão florestal está sendo implementado, com a concessão de terras públicas para a exploração florestal por empresas. Nesse modelo, o controle da atividade florestal é muito maior. Um dos aspectos do controle florestal, que se dá no nível da paisagem, é o monitoramento do corte seletivo com o uso de imagens de satélite e técnicas de geoprocessamento. Entretanto, por se tratar de um fenômeno mais complexo de detectar e classificar que o corte raso, esse monitoramento tem limitações. Este trabalho buscou avaliar os impactos da exploração florestal na primeira concessão florestal do Brasil, na Floresta Nacional do Jamari, no estado de Rondônia, com o uso de dados do inventário florestal da área, dados de campo e imagens de satélite. A primeira etapa se baseou na coleta e análise de dados de abertura de dossel nos diferentes estratos das áreas exploradas; a segunda etapa consistiu no desenvolvimento e aplicação de uma abordagem para a detecção da infraestrutura para a exploração florestal em imagens Landsat e RapidEye; e a terceira avaliou a relação existente entre a exploração florestal percebida pelas imagens de satélite e os dados de campo e da volumetria das árvores exploradas. Os resultados da análise dos dados de campo indicaram a existência de um gradiente de abertura de dossel nos diferentes estratos das áreas exploradas e que não houve diferença significativa nesse indicador de impacto entre as duas áreas de estudo. Para a segunda etapa, os resultados apontam o NDVI como a melhor técnica para a detecção da infraestrutura nas imagens RapidEye e a Análise de Componentes Principais nas imagens Landsat, mas que a detecção para essa última é pouco efetiva. Na terceira etapa, concluiu-se que o volume das árvores abatidas não é correlacionado com os valores dos índices de vegetação, e que a fração de cobertura florestal derivada do NDVI estimou com maior precisão a abertura de dossel obtida a partir dos dados de campo. Ainda, chegou-se a conclusão de que os pátios de estocagem, estradas primárias, estradas secundárias, clareiras de árvores e trilhas de arraste contribuem com 35.5%, 21.5%, 5.6%, 5.7% e 0.5%, respectivamente para a diminuição da cobertura florestal. Os resultados desse estudo contribuem para a consolidação do sistema de monitoramento das concessões florestais no Brasil. ___________________________________________________________________________ ABSTRACT / Forest resources in the Amazon region have been severely exploited in the last decades. To mitigate those impacts in the forests, a new forest management model has been conducted on public lands, involving forest concession to logging companies. Under this model, forest activities can be better controlled. One of the aspects of this control, which is taken at the landscape level, is the monitoring of selective logging using satellite imagery and geoprocessing techniques. However, this monitoring has some implicit constraints, because selective logging impacts on forest are subtle to be detected on satellite images. This study intended to assess the impacts of selective logging at the first forest concession site in Brazil, at Jamari National Forest, State of Rondônia, using forest inventory, fieldwork and remotely sensed data. Initially, this study involved collecting and analyzing gap fraction data at the different forest canopy stratum within selectively logged areas; secondly, it was developed and applied a forest infrastructure detection technique in two logged areas using Landsat and RapidEye imagery; finally, I assessed the relationship between selective logging impacts on forest canopy using remotely sensed and field and inventory data. These study results indicate that there is a gradient of gap fraction in different forest canopy stratum within selectively logged forests and that there was no significant changes in forest canopy between the two study sites. I also observed that forest infrastructure was better detected using NDVI derived from RapidEye images and using Principal Component Analysis applied on Landsat images, however, logging detection for the 30 meters spatial resolution was very poor. Most importantly, this study result indicates that tree volume was not well correlated with vegetation indices and that fractional coverage derived from NDVI estimated with higher precision gap fraction based on field data. I also observed that log decks, primary roads, secondary roads, tree fall gaps and skid trails contributed to decrease 35.5%, 21.5%, 5.6%, 5.7% e 0.5% of forest canopy, respectively. This study may improve the Brazilian forest concessions monitoring system.
102

Desenvolvimento de um instrumento para avaliar funções cardiacas : unidade de condicionamento

Bellentani, Icaro F 23 July 1991 (has links)
Orientador: Maria Adelia Collier Farias / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-22T05:26:28Z (GMT). No. of bitstreams: 1 Bellentani_IcaroF_M.pdf: 8968342 bytes, checksum: e13998bf0043bafd27a04cc7f01b7f5c (MD5) Previous issue date: 1991 / Resumo: Neste trabalho são apresentados o projeto e a construção de um instrumento que processa analogicamente os sinais de pressão e de eletrocardiograma (ECG), com indicação da ocorrência do complexo QRS. Este equipamento pode ser integrado a um sistema de processamento digital de sinais, para cálculo de parâmetros clínicos de interesse em cardiologia tais como, aplicação ao tratamento de pacientes em unidades de cuidados intensivos. o instrumento é composto de: 1) Módulo de pressão com um amplificador de corrente alternada e detecção síncrona do sinal, onde são obtidos os sinais de pressão em uma saída analógica; 2) Módulo de ECG, composto de um amplificador de ECG, que trabalha com acoplamento óptico direto do sinal, e um circuito de detecção do complexo QRS; 3) Módulo de circuitos auxiliares, composto de um conversor AID de 8 "bits" e 4 canais, um conversor DIA de 8 "bits", e fontes de alimentação de +-5V e +-2V. Foram realizados testes em bancada com o equipamento, obtendo-se resultados satisfatórios / Abstract: Not informed. / Mestrado / Mestre em Engenharia Elétrica
103

Monitorização biológica na exposição ocupacional ao cobalto, aspectos toxicológicos e analíticos associados a um sistema de qualidade. / Biological monitoring of occupational exposure to cobalt, toxicological and analytical aspects associated with a Quality System

Atecla Nunciata Lopes Alves 09 December 1999 (has links)
Este trabalho tem por objetivo uma revisão analítica da determinação de cobalto no sangue e/ou urina para fins de monitorização biológica. A proposta de alternativas viáveis para tal metodologia está fundamentada num estudo crítico dos métodos estudados, associados a um Sistema da Qualidade. Os efeitos tóxicos observados nas exposições a diferentes compostos de cobalto, a relação dose-efeito e dose-resposta, bem como os valores de referência para a população sadia e não ocupacionalmente exposta, levou a ACGIH (American Conference of Governmental Industrial Hygienists) dos Estados Unidos a propor desde 1995 a utilização de um BEI (Biological Exposure Indice) para este tipo de exposição. Apesar de o Brasil ainda não ter incluído o cobalto no Programa de Controle Médico de Saúde Ocupacional da Norma Regulamentadora-7, a utilização de um indicador biológico pode constituir-se numa necessidade devido a estudos toxicológicos e analíticos revistos e relatados na literatura. / This work has the purpose of an analytical review of blood and urine\'s cobalt quantification in order to be used in biological monitoring. A proposal of alternatives and feasible methodologies that habe been found are based upon the crutical study associated with a Quality system. The toxic effects observed in exposure to different cobalt compounds, the dose-effect relationship and dose-response, and the reference values in health and non-exposed population, have brought ACGIH (American Conference of Governmental Industrial Hygienists) of the United States to propose since 1995 a BEI (Biological Exposure Indice) to this kind of exposure. Although Brazil has not included cobalt in the PCMSO (Programa de Controle Médico de Saúde Ocupacional), the use of biological indicator can become a necessity due to toxicological and analytical studies here reviewed and reported in the literature
104

Monitorização terapêutica da olanzapina em pacientes esquizofrênicos / Therapeutic monitoring of olanzapina in schizophrenic patients

Marina Salviato Balbão Santiago Fonseca 04 August 2009 (has links)
A olanzapina é um fármaco antipsicótico atípico utilizado no tratamento da esquizofrenia. Como efeitos adversos relacionados ao seu uso encontram-se obesidade, hiperlipidemia, diabetes mellitus tipo 2 e hipertensão, podendo acarretar no desenvolvimento de síndrome metabólica. O presente trabalho tem por objetivo realizar a monitorização terapêutica em pacientes na terapia com olanzapina, estabelecendo uma possível correlação entre a dose-concentração plasmática e a potenciação do risco a reações adversas, constituindo suporte clínico na eficácia do tratamento. A análise dos parâmetros antropométricos (peso, índice de massa corpóreo, circunferência do braço, circunferência do abdome, circunferência do quadril, prega cutânea triciptal, prega cutânea biciptal, prega cutânea subescapular, prega cutânea suprailíaca, resistência, porcentagem de massa gorda e taxa metabólica basal), parâmetros hemodinâmicos (pressão arterial sistólica, pressão arterial diastólica e freqüência cardíaca) e parâmetros bioquímicos (aspartato aminotranferase, alanina aminotransferase, gama glutamiltransferase, creatinina, ácido úrico, amilase, insulina, bilirrubinas, glicemia, cálcio, sódio e potássio), perfil lipídico (colesterol total, LDLcolesterol, HDL-colesterol e triglicérides), concentração de homocisteína e proteína C reativa, são relevantes na medida em que representam marcadores importantes de alterações relacionadas a desordens metabólicas ou de risco aterosclerótico. Como a obesidade e as coronariopatias podem induzir tais alterações, é importante avaliar qual o risco que o aumento de peso induzido pela olanzapina traz para o paciente esquizofrênico. A análise estatística foi realizada utilizando-se um modelo linear de efeito misto, apropriado para análise de medidas realizadas ao longo de um período pré-estabelecido. O nível de significância foi fixado em p<0,05. / The olanzapine is an atypical antipsychotic drug used to treat schizophrenia. How adverse effects related to its use, are obesity, hyperlipidemia, diabetes mellitus type II and hypertension, may result in the development of metabolic syndrome. This study aims to carry out monitoring therapy in patients in treatment with olanzapine, establishing a possible correlation between the dose-plasma concentration and potentiation of the risk to adverse reactions, providing clinical support in the effectiveness of treatment. Analysis of anthropometric parameters (weight, body mass index, arm circumference, circumference of the abdomen, the hip circumference, triceps skinfold thickness, biciptal skin fold, subscapular skin fold, skin fold suprailíaca, strength, percentage of fat mass and metabolic rate basal), hemodynamic parameters (systolic blood pressure, diastolic blood pressure and heart rate) and biochemical parameters (aspartate aminotranferase, alanine aminotransferase, gamma glutamyl transferase, creatinine, uric acid, amylase, insulin, total bilirubin, glucose, calcium, sodium and potassium ), lipid profile (total cholesterol, LDL-cholesterol, HDL-cholesterol and triglycerides), concentration of homocysteine and C-reactive protein, are relevant in so far represent important markers of changes related to metabolic disorders and atherosclerotic risk. As obesity and coronary diseases can induce such changes, which is important to evaluate the risk that the weight gain induced by olanzapine brings to the schizophrenic patient. Statistical analysis was performed using a mixed effect linear model, suitable for analysis of measurements taken over a pre-established. The significance level was set at p <0.05.
105

Farmacovigilância: monitorização intensiva de vancomicina em pacientes hospitalizados / Pharmacovigilance: intensive monitoring of vancomycin in hospitalized patients

Maira Umezaki de Queiroz Netto 17 August 2010 (has links)
Os eventos adversos, devido à grande ocorrência, são considerados um importante problema de saúde pública além de elevarem os custos com a saúde. Dessa forma, existe a necessidade de um sistema eficiente de farmacovigilância para prevení-los sendo a monitorização intensiva uma excelente estratégia para se alcançar este objetivo, pois permite a identificação e o conhecimento dos eventos adversos, além de medir sua incidência e melhorar as notificações voluntárias. Por esta razão, o presente estudo propôs a avaliação deste método em eventos adversos relacionados ao antimicrobiano vancomicina. As informações coletadas, provenientes dos bancos de dados e dos prontuários do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto (HCFMRP-USP), são referentes aos pacientes internados no hospital em tratamento com vancomicina no período de 01/09/2008 a 31/08/2009. Identificou-se 1719 tratamentos de 1302 usuários. Destes tratamentos, 521 foram excluídos por serem profiláticos. A idade média dos 1198 pacientes monitorados foi de 39,33 (± 27,66) anos e 58,68% pertenciam ao gênero masculino. Os diagnósticos infecciosos prevalentes para o tratamento com vancomicina foram pneumonia (18,95%), sepse (11,19%) e infecção relacionada a cateter (10,27%) com período médio de duração do tratamento de 11,47 (±7,79) dias geralmente na dose de 2000 mg ao dia (35,98%). Foram identificados indicadores de eventos adversos em 85,81% dos tratamentos, sendo a incidência de eventos adversos de 7,18%. A incidência de reações adversas (RAM) foi de 5,93% e de erros de medicação 2,57%. A causalidade das RAM foi prevalentemente provável (49,29%) e a gravidade moderada (54,93%). As RAM foram essencialmente do tipo B (81,69%) e os erros de medicação relativos à prescrição (87,10%). A comparação entre os grupos controle e estudo não apresentou diferenças significativas, demonstrando a necessidade de monitorização de todos os parâmetros relacionados a eventos adversos com a vancomicina. Dessa forma, fica evidente a importância da monitorização intensiva e da presença dos farmacêuticos clínicos na equipe de saúde para melhorar a eficiência da farmacovigilância, como demonstrado por este estudo. Diante dos resultados, conclui-se que o método de monitorização intensiva utilizando base de dados e prontuários, além da participação de um farmacêutico clínico, promove o conhecimento, a avaliação e a compreensão dos eventos adversos presentes em uma instituição, permitindo a esquematização de estratégias para a sua prevenção. / Adverse events, due to the high occurrence, are considered an important public health problem in addition to driving up health care costs. There is therefore a need for an efficient system of pharmacovigilance to prevent them being the intensive monitoring an excellent strategy for achieving this goal because it allows the identification and knowledge of the adverse events, in addition to measuring its incidence and improve spontaneous reports. For this reason, the present study evaluated this method in adverse events related to antibiotic vancomycin. The informations collected from databases and records of the Hospital of the Medical School of Ribeirão Preto-SP (USP-HCFMRP), refers to hospital patients treated with vancomycin for the period 01/09/2008 to 31/08/2009. We evaluated 1719 treatments in 1302 users, of which 521 were excluded because they were prophylactic. The average age of 1198 patients was 39.33 years (±27.66) and 58.68% were males. Prevalent infectious diagnoses for treatment with vancomycin were pneumonia (18.95%), sepsis (11.19%) and catheter-related infection (10.27%) with mean duration of treatment of 11.47 days (± 7.79) usually at a dose of 2000 mg daily (35.98%). We identified indicators of adverse events in 85.81% of treatments, and the incidence of adverse events was 7.18%. The adverse drug reactions (ADR) incidence was 5.93% and 2.57% of medication errors. The causality of ADR was probable (49.29%) and severity was moderate (54.93%). The ADR were mainly of type B (81.69%) and medication errors related to prescription (87.10%). Comparisons between the study and control groups showed no significant differences, demonstrating the need for monitoring of all parameters related to adverse events with vancomycin. Thus, it is clear the importance of the intensive monitoring and the presence of clinical pharmacists in the health team to improve the efficiency of pharmacovigilance, as demonstrated by this study. Before the results, we conclude that the method of intensive monitoring using the database and records, plus the involvement of a clinical pharmacist, promotes knowledge, assessment and understanding of adverse events presents in an institution, enabling the layout of strategies to prevention.
106

Estudo dos níveis de pressão arteial estável e pulsátil obtidos por monitorização residencial da pressão arterial e sua influência sobre o índice de massa de ventrículo esquerdo

de Marco, André January 2005 (has links)
Made available in DSpace on 2014-06-12T18:29:38Z (GMT). No. of bitstreams: 2 arquivo8007_1.pdf: 2539897 bytes, checksum: 09eb24d17155fea95438e7a2df0a3321 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2005 / A Hipertensão arterial sistêmica (HAS) está associada a elevada morbimortalidade cardiovascular. Seu componente pulsátil, a pressão de pulso (PP), tem sido recentemente estudada como forte determinante desta relação. O objetivo deste estudo foi determinar a relação entre a PP medida pela Monitoriação Residencial da Pressão Arterial (MRPA) e o Índice de Massa Ventricular Esquerdo (IMVE). Por análise de banco de dados, foram selecionados 83 pacientes, hipertensos ou não, que realizaram MRPA e ecocardiograma em um período menor que 6 meses, no ano de 2004. Os critérios de exclusão foram: idade inferior a 18 anos, valvulopatias mitral ou aórtica, presença de disfunção segmentar e fração de ejeção inferior a 55% ao ecocardiograma. Permaneceram 72 pacientes para a análise, sendo 41 mulheres e 31 homens, com idade média de 52 ± 17 anos, com variação de 25 a 85 anos. O índice de massa corporal (IMC) foi de 29 ± 6 Kg/m2, e 63,9% dos pacientes eram hipertensos. O sexo feminino apresentou maior idade e usou anti-hipertensivos em maior frequência. Houve elevação progressiva da pressão arterial sistólica (PAS) e da PP com a idade, mas nem estas nem a pressão arterial distólica (PAD) variaram com o sexo ou com o IMC. A média do IMVE foi 109 ± 25 g/m2 e não houve diferença entre os sexos. Foram considerados hipertensos os pacientes com PAS>135 mmHg ou PAD>85 mmHg ou que usavam antihipertensivos. Hipertrofia ventricular esquerda (HVE) foi definida como IMVE>134 g/m2 em homens e >110 g/m2 em mulheres. Foi encontrada relação significativa entre HAS e HVE (p=0,02) e entre PP>53 mmHg e aumento do IMVE (p=0,003). Na análise de regressão linear foi observado correlação entre o IMVE e a PAS (r=0,356; p=0,002) e o IMVE e a PP (r=0,429; p<0,001), e não houve correlação com a PAD (r=0,0459; p=0,702). A análise de regressão múltipla passo a passo para correlacionar a IMVE com as demais variáveis, determinou que a PP isoladamente construiria a melhor equação para determinar o IMVE. As mulheres com PP< 53 mmHg apresentaram IMVE de 100,3 g/m2 e as com PP>53 mmHg, de 120,8 g/m2 (p=0,016), o que implica no diagnóstico de HVE. Entre os homens, esta diferença não foi significativa (107,2 g/m2 e 122,6 g/m2 ; p=0,078). Concluindo, estes dados demonstram que o IMVE correlacionou-se com a PP, e que esta correlação foi ainda maior que com a PAS ou a PAD
107

Oximetro para medida de saturação de oxigenio em linhas de circulação extracorporea

Ushizima, Mauro Roberto 17 October 1995 (has links)
Orientador: Sergio Santos Muhlen / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-25T19:27:38Z (GMT). No. of bitstreams: 1 Ushizima_MauroRoberto_M.pdf: 6361548 bytes, checksum: 7b57168abfb3fc88689c71d908e160c1 (MD5) Previous issue date: 1995 / Resumo: Este trabalho descreve a construção de um protótipo de aparelho para medir a saturação de oxigênio (802) nas linhas de perfusão arterial e venosa em procedimentos cirúrgicos com circulação extracorpórea (CEC). O protótipo desenvolvido é composto por dois sensores ópticos, um para a linha arterial e outro para a linha venosa, e um módulo de processamento. Cada sensor contém dois LEDs com pico de emissão nos comprimentos de onda de 660 nm e 850 nm e também um fotodiodo que opera medindo a transmissão de luz através de uma camada de sangue. O acoplamento entre o sangue e o sensor óptico é obtido através de uma cubeta especialmente desenvolvida para esta aplicação. A intensidade luminosa transmitida pela camada de sangue é detectada pelo fotodiodo e convertida da forma analógica para a forma digital sendo então processada para o cálculo da 802. O resultado é apresentado no painel frontal do protótipo em visar de cristal líquido. A partir do teclado, também posicionado no painel frontal, é permitido ao usuário ajustar o nível arterial e venoso da 802 abaixo do qual um alarme é ativado indicando medida inferior a estes níveis preestabelecidos. Os resultados obtidos com o protótipo nos testes in vitro mostraram boa correlação (r2=0,97,n=85) com os valores de saturação de oxigênio determinados por aparelho comercial com a concentração de hemoglobina variando entre 8 e 12 g/dl. O erro encontrado na medida da saturação de oxigênio foi inferior a 2% na faixa de 802 entre 80 e 100%, e inferior a 3% de 50 a 80%. Testes in vitro demonstraram que o uso da cubeta na linha de CEC não causa hemólise. O protótipo foi testado em um cão durante o procedimento cirúrgico com CEC. Neste experimento, o índice de correlação entre os resultados fornecidos por aparelho de gasometria comercial e o cálculo da saturação de oxigênio na linha arterial foi de r2=0,93 (n=9) e na linha venosa foi de r=0,88 (n=10). Estes resultados encorajaram a utilização do protótipo em sala de cirurgia com CEC. A inserção das cubetas nas linhas de circulação sangüínea não causou alterações dos procedimentos normais da rotina de uma operação com CEC / Abstract: This work describes a prototype for assessment of the oxygen saturation (OS) in flowing whole blood through the arterial and venous tubing utilized in extracorporeal circulation (ECC) equipment during cardiopulmonary bypass surgical procedures. The prototype utilizes an optical transducer with two LED (peak emission in 660 nm and 850 nm) and a photodiode operating in transmittance mode. A special cuvette was developed allowing easy attachment of the transducer to the tubing without causing haemolysis. The analog signal from light transmitted through blood is detected by the photodiode and converted to digital form to be read by a microcontroller chip for further processing. The result is shown on the prototype front paneI on a LCD. A keyboard also placed on the front panel allow users to adjust arterial and venous levei of OS below which an audible alarm is activated warning a low OS leveI. In vitro tests have shown high correlation between the readings provided by the prototype and a commercial blood gas analyzer. Correlation index of 0.99 was found for constant hemoglobin concentration. Correlation index of 0.97 was found for hemoglobin concentration varying from 8 to 12 g/dl and oxygen saturation from 50 to 100%. OS measurement was not affected by temperature and flow rate. In these tests, the standard error of the measurement was smaller than 2% for OS varying from 80 to 100% and smaller than 3% for OS varying from 50 to 80%. An in vivo experiment was performed in which a dog was maintained in ECC for two hours. In this experiment a correlation index of 0.93 was obtained for arterial OS and 0.88 for venous OS. The prototype was used in operating room encouraged by results obtained during in vitro te$ts. The prototype sensors and cuvettes were used attached to ECC tubing without changing the normal routine of the surgical procedure. Obtained results open the possibility of the application of the described methods in continuous and real time measurements of OS / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
108

Efeito da analgesia obstétrica combinada raqui-peridural no tônus uterino e na freqüência cardíaca fetal: ensaio clínico randomizado comparativo com a analgesia peridural / The effect of combined spinal-epidural labor analgesia on uterine tone and fetal heart rate: randomized comparison with epidural analgesia

Abrão, Karen Cristine 20 August 2008 (has links)
A fim de investigar a associação entre alterações do tônus uterino e a ocorrência de anormalidades da freqüência cardíaca fetal (FCF) após analgesia obstétrica, em especial após o bloqueio combinado raqui-peridural, foi conduzido estudo prospectivo randomizado e encoberto, com setenta e sete parturientes que solicitaram analgesia regional durante o trabalho de parto. As pacientes do grupo estudo (41 casos) receberam duplo bloqueio com sufentanil e bupivacaína e as do grupo controle (36 casos) foram submetidas à peridural com as mesmas drogas. Monitorizou-se o tônus uterino por meio de cateter intra-amniótico de aferição da pressão intra-uterina e a freqüência cardíaca fetal durante 15 minutos antes e 30 minutos após a indução da analgesia. Pesquisaram-se os seguintes desfechos após a administração da analgesia: ocorrência de aumento do tônus uterino superior ou igual a 10mmHg em relação aos valores pré-analgesia e presença de desacelerações prolongadas da FCF ou bradicardia. Foram ainda quantificados os escores maternos de dor, a pressão arterial materna e o uso de ocitocina, antes e após o bloqueio. Observou-se associação significativa tanto do aumento de tônus uterino quanto das alterações da FCF com a analgesia combinada, nos primeiros 15 minutos após sua administração. O aumento de tônus foi encontrado em 17 de 41 casos no grupo estudo e em 6 de 36 pacientes nos controles (p=0,02). Alterações da FCF foram vistas em 11 dos 17 casos de aumento de tônus nas parturientes que receberam analgesia combinada, versus 1 de 6 no grupo peridural (p<0,001) A análise de regressão logística apontou o tipo de analgesia como fator independentemente associado ao aumento de tônus uterino, mesmo inserindo-se o uso de ocitocina como covariável. Também revelou o aumento de tônus como único fator independentemente associado ao desenvolvimento de anormalidades da FCF, mesmo com a hipotensão materna como covariável. Demonstrou-se ainda correlação entre o rápido declínio da dor com a técnica combinada e a probabilidade estimada de ocorrência simultânea de aumento do tônus e alterações da FCF. Os presentes achados reforçam a teoria de que o duplo bloqueio pode levar a aumento transitório de tônus uterino e culminar em anormalidades da FCF / In order to investigate the association between uterine tone elevation and fetal heart rate (FHR) abnormalities following labor analgesia - mainly with combined spinal-epidural (CSE) technique - a prospective double-blinded randomized study was conducted with seventy seven parturients who requested labor analgesia. Study group (41 cases) received CSE with sufentanil and bupivacaine and control group (36 cases) received epidural analgesia with the same drugs. Intra-uterine pressure was monitored with intra-amniotic pressure device and FHR with external transducer, both for at least 15 minutes before and 30 minutes after analgesia induction. The primary outcomes were the occurrence of an elevation of 10mmHg or more on uterine tone compared to the values before analgesia and the presence of prolonged fetal heart rate decelerations or fetal bradycardia. Maternal pain scores, blood pressure and use of oxytocin were also computed. A significant association was noticed between elevation of uterine tone and fetal heart rate abnormalities with combined spinal-epidural analgesia, at the first 15 minutes of administration. Uterine tone elevation was observed in 17 out of 41 CSE subjects and only 6 out of 36 controls (p=0.02). Fetal heart rate abnormalities were seen in 11 out of 17 cases that had hypertonus with combined analgesia and in only one of the 6 epidural patients (p<0.001). Logistic regression analysis revealed the mode of analgesia as the independent factor for the elevation of uterine tone, even with oxytocin use as a covariate. It also pointed out the uterine tone elevation as the only independent factor related to the development of fetal heart rate abnormalities, even with maternal hipotension as a covariate. A correlation was found between the fast onset pain relief provided by CSE analgesia and the estimated probability of uterine tone elevation and simultaneous fetal heart rate abnormalities. The present results strengthen the hypothesis that CSE analgesia can lead to a transient increase in uterine tone, leading to fetal bradycardia
109

Efeito da analgesia obstétrica combinada raqui-peridural no tônus uterino e na freqüência cardíaca fetal: ensaio clínico randomizado comparativo com a analgesia peridural / The effect of combined spinal-epidural labor analgesia on uterine tone and fetal heart rate: randomized comparison with epidural analgesia

Karen Cristine Abrão 20 August 2008 (has links)
A fim de investigar a associação entre alterações do tônus uterino e a ocorrência de anormalidades da freqüência cardíaca fetal (FCF) após analgesia obstétrica, em especial após o bloqueio combinado raqui-peridural, foi conduzido estudo prospectivo randomizado e encoberto, com setenta e sete parturientes que solicitaram analgesia regional durante o trabalho de parto. As pacientes do grupo estudo (41 casos) receberam duplo bloqueio com sufentanil e bupivacaína e as do grupo controle (36 casos) foram submetidas à peridural com as mesmas drogas. Monitorizou-se o tônus uterino por meio de cateter intra-amniótico de aferição da pressão intra-uterina e a freqüência cardíaca fetal durante 15 minutos antes e 30 minutos após a indução da analgesia. Pesquisaram-se os seguintes desfechos após a administração da analgesia: ocorrência de aumento do tônus uterino superior ou igual a 10mmHg em relação aos valores pré-analgesia e presença de desacelerações prolongadas da FCF ou bradicardia. Foram ainda quantificados os escores maternos de dor, a pressão arterial materna e o uso de ocitocina, antes e após o bloqueio. Observou-se associação significativa tanto do aumento de tônus uterino quanto das alterações da FCF com a analgesia combinada, nos primeiros 15 minutos após sua administração. O aumento de tônus foi encontrado em 17 de 41 casos no grupo estudo e em 6 de 36 pacientes nos controles (p=0,02). Alterações da FCF foram vistas em 11 dos 17 casos de aumento de tônus nas parturientes que receberam analgesia combinada, versus 1 de 6 no grupo peridural (p<0,001) A análise de regressão logística apontou o tipo de analgesia como fator independentemente associado ao aumento de tônus uterino, mesmo inserindo-se o uso de ocitocina como covariável. Também revelou o aumento de tônus como único fator independentemente associado ao desenvolvimento de anormalidades da FCF, mesmo com a hipotensão materna como covariável. Demonstrou-se ainda correlação entre o rápido declínio da dor com a técnica combinada e a probabilidade estimada de ocorrência simultânea de aumento do tônus e alterações da FCF. Os presentes achados reforçam a teoria de que o duplo bloqueio pode levar a aumento transitório de tônus uterino e culminar em anormalidades da FCF / In order to investigate the association between uterine tone elevation and fetal heart rate (FHR) abnormalities following labor analgesia - mainly with combined spinal-epidural (CSE) technique - a prospective double-blinded randomized study was conducted with seventy seven parturients who requested labor analgesia. Study group (41 cases) received CSE with sufentanil and bupivacaine and control group (36 cases) received epidural analgesia with the same drugs. Intra-uterine pressure was monitored with intra-amniotic pressure device and FHR with external transducer, both for at least 15 minutes before and 30 minutes after analgesia induction. The primary outcomes were the occurrence of an elevation of 10mmHg or more on uterine tone compared to the values before analgesia and the presence of prolonged fetal heart rate decelerations or fetal bradycardia. Maternal pain scores, blood pressure and use of oxytocin were also computed. A significant association was noticed between elevation of uterine tone and fetal heart rate abnormalities with combined spinal-epidural analgesia, at the first 15 minutes of administration. Uterine tone elevation was observed in 17 out of 41 CSE subjects and only 6 out of 36 controls (p=0.02). Fetal heart rate abnormalities were seen in 11 out of 17 cases that had hypertonus with combined analgesia and in only one of the 6 epidural patients (p<0.001). Logistic regression analysis revealed the mode of analgesia as the independent factor for the elevation of uterine tone, even with oxytocin use as a covariate. It also pointed out the uterine tone elevation as the only independent factor related to the development of fetal heart rate abnormalities, even with maternal hipotension as a covariate. A correlation was found between the fast onset pain relief provided by CSE analgesia and the estimated probability of uterine tone elevation and simultaneous fetal heart rate abnormalities. The present results strengthen the hypothesis that CSE analgesia can lead to a transient increase in uterine tone, leading to fetal bradycardia
110

Aplicação de conceitos BIM à instrumentação de estruturas

Ferreira, Bruno Filipe Vieira January 2011 (has links)
Tese de mestrado integrado. Engenharia Civil. Faculdade de Engenharia. Universidade do Porto. 2011

Page generated in 0.0741 seconds