• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 61
  • 17
  • 15
  • 14
  • 12
  • 7
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 157
  • 28
  • 18
  • 15
  • 12
  • 12
  • 11
  • 11
  • 11
  • 11
  • 10
  • 10
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Análise clínico – experimental de um conjunto dilatador coaxial permanente acoplado a agulha de punção para nefrolitotomia percutânea

BARROS, Evandilson Guenes Campos de 31 August 2012 (has links)
Submitted by Heitor Rapela Medeiros (heitor.rapela@ufpe.br) on 2015-03-05T12:42:56Z No. of bitstreams: 2 Dissertaçao Evandilson de Barros.pdf: 4780358 bytes, checksum: 698c6820897c9bb3109fbdd77be31f38 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-05T12:42:56Z (GMT). No. of bitstreams: 2 Dissertaçao Evandilson de Barros.pdf: 4780358 bytes, checksum: 698c6820897c9bb3109fbdd77be31f38 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012-08-31 / Abordagem percutânea renal é uma alternativa cirúrgica que minimiza a morbidade de uma variedade de procedimentos envolvidos na intervenção aberta, que requerem incisão de camadas musculares, levando ao maior tempo de permanência hospitalar e dor pós-operatória. Objetivo: Avaliar a eficácia, praticidade e segurança do dilatador coaxial metálico, utilizando sistema acoplado agulha-dilatadores-bainha, na confecção de nefrostomias para nefrolitotomia percutânea. Métodos: Foi realizado um estudo experimental randomizado, constituído por 50 pacientes do Sistema Único de Saúde (SUS), atendidos no ambulatório de urologia do Hospital das Clínicas da Universidade Federal de Pernambuco, portadores de nefrolitíase com indicação cirúrgica de nefrolitotomia percutânea. Cinquenta pacientes foram randomizados em dois grupos: grupo 1 (padrão): pacientes com prontuários que terminavam em números pares; e grupo 2 (experimental): pacientes nos quais os prontuários terminavam em número ímpar. Aqueles do grupo 1 foram submetidos a NLP pela técnica convencional, utilizando os dilatadores sequenciais de Amplatz, os do grupo 2 foram submetidos ao procedimento utilizando os dilatadores coaxiais acoplados. Foram analisados e comparados: o sexo, IMC, Hb pré e Ht pré; o tempo utilizado na confecção de nefrostomia – intervalo entre a punção da pelve renal e introdução do nefroscópio, confirmando acesso ao sistema coletor renal; e o tempo de sangramento com relação à Hb e Ht apresentado no pré-operatório imediato, 24h do procedimento e na alta hospitalar. Resultados: Não houve diferença estatisticamente significante entre os dois grupos com relação ao sexo, IMC, Hb pré e Ht pré, podem ser considerados homogêneos para essas características. Com relação ao tempo de dilatação existe diferença estatisticamente significante entre os grupos (p<0,05), o tempo de dilatação do grupo experimental foi muito inferior ao grupo padrão. Foi identificado uma lesão de sistema coletor no grupo 1. No grupo 2, dilatador experimental, não foram identificados complicações maiores. A presença desta única lesão não tem significado estatístico para o presente estudo. Conclusão: O conjunto dilatador coaxial acoplado para utilização em cirurgias percutâneas renais é um aparelho seguro, de fácil confecção e manuseio, apresenta índices de efetividade e complicações semelhantes aos utilizados comercialmente.
32

Through Wafer 3D Vertical Micro-Coaxial Probe for High Frequency Material Characterization and Millimeter Wave Packaging Systems

Boone, Justin 17 May 2013 (has links)
This work presents the development of an in-plane vertical micro-coaxial probe using bulk micromachining technique for high frequency material characterization. The coaxial probe was fabricated in a silicon substrate by standard photolithography and a deep reactive ion etching (DRIE) technique. The through-hole structure in the form of a coaxial probe was etched and metalized with a diluted silver paste. A co-planar waveguide configuration was integrated with the design to characterize the probe. The electrical and RF characteristics of the coaxial probe were determined by simulating the probe design in Ansoft’s High Frequency Structure Simulator (HFSS). The reflection coefficient and transducer gain performance of the probe was measured up to 65 GHz using a vector network analyzer (VNA). The probe demonstrated excellent results over a wide frequency band, indicating its ability to integrate with millimeter wave packaging systems as well as characterize unknown materials at high frequencies. The probe was then placed in contact with 3 materials where their unknown permittivities were determined. To accomplish this, the coaxial probe was placed in contact with the material under test and electromagnetic waves were directed to the surface using the VNA, where its reflection coefficient was then determined over a wide frequency band from dc-to -65GHz. Next, the permittivity of each material was deduced from its measured reflection coefficients using a cross ratio invariance coding technique. The permittivity results obtained when measuring the reflection coefficient data were compared to simulated permittivity results and agreed well. These results validate the use of the micro-coaxial probe to characterize the permittivity of unknown materials at high frequencies up to 65GHz.
33

Analysis of a novel CBHE

GUILLAUME, François January 2011 (has links)
No description available.
34

Study of the Timing Characteristics in Coaxial Ge(Li) Detectors

Panagiotopoulos, Georgia Binikou 07 1900 (has links)
<p> This thesis deals with the theory and application of semi-conductor detectors to timing measurements. The theory section discusses the charge collection times in the coaxial detector. The third chapter describes the experimental procedure for the γ-γ coincidence work, and the fourth part reports the results of studies of the timing characteristics of the coaxial detector.</p> / Thesis / Master of Science (MSc)
35

An experimental model for guided microwave backscattering from wet insulation in pipelines

Bejjavarapu, Sai Munesh January 2014 (has links)
No description available.
36

Design Optimization of a Coaxial Heavy-Lift VTOL UAS

Ouwerkerk, Justin January 2017 (has links)
No description available.
37

Magnetic fields of an underground coaxial cable caused by return currents in the earth

Siegel, Thomas A. January 1989 (has links)
No description available.
38

Retinógrafo coaxial não-midriático / Coaxial non-mydriatic fundus camera

Oliveira, André Orlandi de 04 September 2017 (has links)
Retinógrafo é um complexo sistema óptico que, simultaneamente, ilumina e captura imagens da retina. Basicamente, esse equipamento é composto por três módulos: iluminação, lente objetiva e detecção. Em razão de seu sofisticado desenho óptico, é possível conciliar baixa refletividade da retina e obtenção de imagens de alta qualidade. Entretanto, em virtude do alto número de componentes não-coaxiais do módulo de iluminação, seu alinhamento óptico se torna complexo. Neste trabalho, é apresentado um sistema óptico totalmente coaxial para um retinógrafo nãomidriático. A óptica de iluminação tradicional é substituída por um anel de Surface Mounted Device (SMD) Light Emitting Diodes (LEDs) que, analogamente ao equipamento tradicional, forma um anel de luz no plano da pupila do olho, iluminando homogeneamente a retina e evitando reflexos gerados na córnea. Com essa substituição, os três módulos do equipamento se tornam coaxiais, facilitando o alinhamento final. Devido à inovação da arquitetura do retinógrafo, um novo método de eliminação de reflexos também foi introduzido, possibilitando ao equipamento fornecer imagens nítidas e de alta qualidade, suficientes para exames de triagem. Além da iluminação, os módulos da objetiva e de detecção foram substituídos por componentes comerciais, visando a simplificação do projeto de retinógrafo. Dessa forma, pretende-se reduzir o custo de comercialização do produto, de modo que clínicas no Brasil e em países em desenvolvimento possam ser equipadas e capazes de realizar diagnósticos de doenças do olho que causam perda parcial ou total da visão. / Fundus camera is a complex optical system that simultaneously illuminates and images the retina. It is basically divided into three modules: objective lens, illumination and detection. Because of its sophisticate optical design, it is possible to achieve high-quality images under low reflected light by the fundus. However, due to its high number of off-axis components, mainly in the illumination system, the optical alignment of the equipment can be complex. To simplify the architecture of the equipment, we report a completely coaxial optical system, with no off-axis components. The traditional illumination system is replaced by a ring of light emitting diodes of surface mounted device type. As in the previous design, the eye pupil is illuminated with a ring of light, producing a uniform pattern on the retina and avoiding reflection on the cornea. Due to this new design and the lack of optical components in the illumination system, a new method of avoiding reflection on the surfaces of the objective lens is presented. Besides, the objective lens and the detection system were composed of commercial components, also simplifying the equipment project and lowering its cost. The final goal of this work is to provide non-mydriatic high quality fundus images for screening with a low-cost equipment, enabling developing countries to increase the number of people examined.
39

Retinógrafo coaxial não-midriático / Coaxial non-mydriatic fundus camera

André Orlandi de Oliveira 04 September 2017 (has links)
Retinógrafo é um complexo sistema óptico que, simultaneamente, ilumina e captura imagens da retina. Basicamente, esse equipamento é composto por três módulos: iluminação, lente objetiva e detecção. Em razão de seu sofisticado desenho óptico, é possível conciliar baixa refletividade da retina e obtenção de imagens de alta qualidade. Entretanto, em virtude do alto número de componentes não-coaxiais do módulo de iluminação, seu alinhamento óptico se torna complexo. Neste trabalho, é apresentado um sistema óptico totalmente coaxial para um retinógrafo nãomidriático. A óptica de iluminação tradicional é substituída por um anel de Surface Mounted Device (SMD) Light Emitting Diodes (LEDs) que, analogamente ao equipamento tradicional, forma um anel de luz no plano da pupila do olho, iluminando homogeneamente a retina e evitando reflexos gerados na córnea. Com essa substituição, os três módulos do equipamento se tornam coaxiais, facilitando o alinhamento final. Devido à inovação da arquitetura do retinógrafo, um novo método de eliminação de reflexos também foi introduzido, possibilitando ao equipamento fornecer imagens nítidas e de alta qualidade, suficientes para exames de triagem. Além da iluminação, os módulos da objetiva e de detecção foram substituídos por componentes comerciais, visando a simplificação do projeto de retinógrafo. Dessa forma, pretende-se reduzir o custo de comercialização do produto, de modo que clínicas no Brasil e em países em desenvolvimento possam ser equipadas e capazes de realizar diagnósticos de doenças do olho que causam perda parcial ou total da visão. / Fundus camera is a complex optical system that simultaneously illuminates and images the retina. It is basically divided into three modules: objective lens, illumination and detection. Because of its sophisticate optical design, it is possible to achieve high-quality images under low reflected light by the fundus. However, due to its high number of off-axis components, mainly in the illumination system, the optical alignment of the equipment can be complex. To simplify the architecture of the equipment, we report a completely coaxial optical system, with no off-axis components. The traditional illumination system is replaced by a ring of light emitting diodes of surface mounted device type. As in the previous design, the eye pupil is illuminated with a ring of light, producing a uniform pattern on the retina and avoiding reflection on the cornea. Due to this new design and the lack of optical components in the illumination system, a new method of avoiding reflection on the surfaces of the objective lens is presented. Besides, the objective lens and the detection system were composed of commercial components, also simplifying the equipment project and lowering its cost. The final goal of this work is to provide non-mydriatic high quality fundus images for screening with a low-cost equipment, enabling developing countries to increase the number of people examined.
40

Dielectric Characterization of Biological Tissues for Medical Applications

Fornés Leal, Alejandro 02 December 2019 (has links)
[ES] Conocer las propiedades electromagnéticas de los tejidos biológicos con la mayor exactitud posible tiene una gran importancia en el diseño de un elevado número de aplicaciones biomédicas. El diseño de dispositivos médicos inalámbricos, antenas superficiales e intracorporales, evaluación de tasas de absorción electromagnética, técnicas de tratamiento y detección de cáncer como la hipertermia e imágenes médicas son ejemplos de aplicaciones que requieren esta información para su desarrollo. Debido a que el cáncer provoca modificaciones estructurales en las células que a su vez generan cambios en las propiedades electromagnéticas, es posible desarrollar aplicaciones de detección de cáncer que se basen en este hecho. Un objetivo potencial es el cáncer de colon (CRC), debido a que los tejidos de colon sospechosos son accesibles de forma más o menos sencilla durante procedimientos endoscópicos. Este tipo de cáncer es uno de los más extendidos, siendo responsable de aproximadamente el 10% de casos y muertes totales. Existe un gran número de factores de riesgo que pueden explicar la aparición de la enfermedad, aunque esencialmente la probabilidad se incrementa significativamente con el aumento de la edad de la población. Los programas de cribado sobre la población son críticos: si el cáncer se detecta en etapas tempranas, la probabilidad de sobrevivir se incrementa en gran medida, y además se reducen los costes asociados. Uno de los objetivos principales de esta tesis es proponer aplicaciones que ayuden en la detección de CRC durante la colonoscopia haciendo uso de las diferencias en las propiedades electromagnéticas. Aparte de mejoras en el diagnóstico, complementar la colonoscopia puede conllevar otros beneficios colaterales como una reducción en la carga de anatomía patológica. Para demostrar la viabilidad y el potencial desarrollo futuro de estas aplicaciones, en esta tesis se miden y se trata de encontrar diferencias entre las propiedades electromagnéticas de tejidos sanos, cancerosos y patológicos de colon humano. Las medidas han sido llevadas a cabo mediante la técnica del coaxial terminado en abierto. Con el propósito de incrementar la precisión del método, se ha evaluado el principio de funcionamiento y se ha mejorado el proceso de calibración. Dos fuentes de tejido de colon han sido analizadas en esta tesis: tejidos procedentes de colonoscopias (biopsias) y tejidos obtenidos a partir de procedimientos quirúrgicos. Aparte de tejido sano, se estudian las siguientes patologías: Adenocarcinomas (CRC), adenomas sin displasia, adenomas con bajo grado de displasia, adenomas con alto grado de displasia, hiperplasias y hamartomas. Debido a la alta variabilidad entre distintos sujetos, las propiedades electromagnéticas de los tejidos sospechosos de un paciente en concreto deben ser siempre comparadas con las propiedades de sus tejidos sanos, no evaluadas de forma independiente. El segundo gran objetivo de esta tesis es el desarrollo de una nueva base de datos de las propiedades electromagnéticas de tejidos biológicos medidas in vivo. Ahora mismo, las colecciones disponibles están limitadas en número de tejidos o frecuencias caracterizadas, obligando a los investigadores a escoger bases de datos más completas pero realizadas ex vivo. No obstante, usar este tipo de colecciones tienen fuentes de incertidumbre adicionales dado que las medidas están condicionadas por la deshidratación de los tejidos y la perdida de flujo sanguíneo. El desarrollo de esta nueva base de datos puede facilitar el diseño de aplicaciones que requieran conocer las propiedades electromagnéticas con alto grado de precisión. / [CAT] Conéixer les propietats electromagnètiques dels teixits biològics amb la major exactitud possible té una gran importància en el disseny d'un gran nombre d'aplicacions biomèdiques. El disseny de dispositius metges sense fil, antenes superficials i intracorporales, l'avaluació de taxes d'absorció electromagnètica, tècniques de tractament i detecció de càncer com ara la hipertèrmia i imatges mediques són exemples d'aplicacions que requerixen esta informació. Com el càncer provoca modificacions estructurals en les cèl·lules que generen canvis en les propietats electromagnètiques, es possible desenrotllar aplicacions de detecció de càncer que es basen en este fet. Un objectiu potencial és el càncer de colon (CRC), pel fet que els teixits de colon sospitosos són accessibles de forma més o menys senzilla durant procediments endoscòpics. Este tipus de càncer és un dels més estesos, sent responsable d'aproximadament el 10% de casos i morts totals. N'hi ha un gran nombre de factors de risc que poden explicar l'aparició de la malaltia, encara que en resum la probabilitat s'incrementa significativament amb l'augment de l'edat de la població. Els programes de cribratge sobre la població són crítics. Si el càncer es detecta en etapes primerenques, la probabilitat de sobreviure s'incrementa en gran manera, i a més es reduïxen els costos associats. Un dels objectius principals d'esta tesi és proposar aplicacions que ajuden en la detecció de CRC durant la colonoscòpia fent ús de les diferències en les propietats electromagnètiques. A banda de millores en el diagnòstic, complementar la colonoscòpia pot comportar altres beneficis col·laterals com una reducció en la càrrega d'anatomia patològica. Per a demostrar la fiabilitat i el potencial desenrotllament d'aquestes aplicacions, en aquesta tesi es mesuren i es tracta de trobar diferències entre les propietats electromagnètiques de teixits sans, cancerosos i patològics de colon humà. Les mesures han sigut realitzades mitjançant la tècnica del coaxial acabat en obert. Amb el propòsit d'incrementar la precisió del mètode, s'ha avaluat el seu principi de funcionament i s'ha millorat el procés de calibratge. Dos fonts de teixit de colon s'han analitzat en aquesta tesi: teixits procedents de colonoscòpies (biòpsies) i teixits obtinguts a partir de procediments quirúrgics. Apart de teixit sà, s'estudien els següents teixits: Adenocarcinomes (CRC), adenomes sense displàsia, adenomes amb baix grau de displàsia, adenomes amb alt grau de displàsia, hiperplàsies y hamartomes. Degut a l'alta variabilitat entre diferents subjectes, les propietats electromagnètiques dels teixits sospitosos d'un pacient en particular han de ser comparades amb les propietats dels seus teixits sans, no avaluats independentment. El segon gran objectiu d'esta tesi és el desenrotllament d'una nova base de dades de les propietats electromagnètiques de teixits biològics mesurades in vivo. Ara mateix, les col·leccions disponibles estan limitades en nombre de teixits o freqüències caracteritzades, obligant els investigadors a triar bases de dades més completes però realitzades ex vivo. No obstant això, este tipus de col·leccions te fonts d'incertesa addicionals atés que les mesures estan condicionades per la deshidratació dels teixits i la pèrdua de flux sanguini. El desenrotllament d'esta nova base de dades pot facilitar el disseny d'aplicacions que requerisquen conéixer les propietats electromagnètiques amb alt grau de precisió. / [EN] Nowadays, a careful knowledge of the electromagnetic properties of biological tissues is required for developing a great number of applications. The development of wireless medical devices, the design of in-body and on-body antennas, specific absorption rate evaluations, cancer treatment techniques such as hyperthermia and detection techniques like medical imaging are some examples of applications that rely on these data. Since cancer causes modifications on the biological structure of cells that can lead in turn to changes in the electromagnetic properties of the tissues, it is possible to develop novel detection applications taking advantage of it. One potential target is colorectal cancer (CRC), as suspicious tissues can be accessed quite easily through colonoscopy procedures. This kind of cancer is one of the most spread kinds, being responsible of about 1 out of 10 new cancer cases and deaths. There are several risk factors currently related to the apprising of this cancer, although in essence the higher the age of the population, the higher the incidence of CRC. Screening programs are key for detecting and diagnosing cancer: if found at early stages, the probability of survival increases greatly, and the cost of the treatment can be reduced as well. One of the major objectives of this dissertation is proposing applications for detecting CRC that aid in the colonoscopy procedures by making use of the differences in electromagnetic properties. Aside from enhancement in the diagnosis of CRC, improving the colonoscopy procedure can lead to collateral benefits like a lowering of the burden of anatomical pathology unit. With the aim at demonstrating the feasibility and the potential future development of these applications, in the framework of this thesis the dielectric properties of healthy, cancerous and pathological human colon tissues are measured and compared in order to find electromagnetic differences. Measurements are carried out by means of an open-ended coaxial system. Its principle of operation has been revisited with the aim at maximizing the accuracy of the method, and the calibration procedure has been optimized serving the same purpose. Two main sources of colon tissue have been analyzed: samples from colonoscopy biopsies and samples from surgery resections. Besides healthy tissue, the following colon tissues have been characterized: Adenocarcinomas (CRC), adenomas without dysplasia, adenomas with low-grade dysplasia, adenomas with high-grade dysplasia, hyperplastic polyps and hamartomatous polyps. Given the variability that can appear among subjects, the electromagnetic properties of suspicious tissues from a particular patient have to be always compared with those of his healthy ones, not evaluated independently. The second major objective of this thesis involves the development of a new database of electromagnetic properties of biological tissues obtained at in vivo conditions. Nowadays, the available collections are limited either in the number of tissues or the measured frequencies, and hence researchers have to make use of more complete databases but that were performed ex vivo. The drawback of using these collections is that results can be compromised by factors such as lack of blood perfusion and tissue dehydration. Developing this new database can facilitate the design of applications that needs of a careful knowledge of these properties. / Fornés Leal, A. (2019). Dielectric Characterization of Biological Tissues for Medical Applications [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/132188 / TESIS

Page generated in 0.0249 seconds