• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 6
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Interacció i emergència. L'espai públic com a escenari d'esdeveniments

Uribe Vilarrodona, Juan 30 April 2008 (has links)
La recollida d'emergències produïdes a l'espai públic permet estudiar la fragilitat de l'ordre públic i com s'empren estratègies per controlar i evitar situacions de crisi.El treball etnogràfic desenvolupat a Barcelona, Hospitalet de Llobregat i Lloret de Mar recollint aquest tipus d'emergències, i en els dos últims municipis esmentats concretament les emergències abordades per la policia, ha permès observar fins a quin punt les emergències crítiques mostren el risc de fractura, però igualment, l'esforç que els membres de la comunitat fan per que aquest no es trenqui, i així poder mantenir les seves legítimes expectatives envers l'assoliment de les fites de la seva quotidianitat.També, mitjançant el paper de la majoria davant l'emergència, que pot passar per ignorar-la, observar-la des de la distància, estudiar-la amb deteniment i recollir la possible informació que es desprengui del seu desenvolupament o participar-ne en considerar que cal activar xarxes socials de recolzament o solidaritat, es possible entendre fins a quin punt es fa palès que per la societat, com diu Isaac Joseph citant a Erving Goffman, és més important restablir l'ordre social, vehicle i via per poder continuar amb el que fem, que aturar o neutralitzar als contraventors. Es visibilitza també fins a quin punt, sabedors de la nostra major vulnerabilitat en l'arena social jugada en l'espai públic, per una part prenem mesures de defensa en forma de distàncies, fugides, canvis de ritme, observacions a distància, xarxes instantànies de solidaritat, i recollim experiències i informació sobre emergències per una altra, per tal que aquest bagatge ens ajudi en el moment en que nosaltres siguem subjectes actius de l'emergència.Tanmateix, és possible albirar a través de la resposta de la policia davant l'emergència, la intenció del Poder, que es fonamenta tant en mirar de garantir aquestes expectatives de "via expedita" social que les persones exigeixen dels responsables de la gestió social, com de minimitzar la poderosa evidència que la seguretat no es pot garantir, així com d'invisibilitzar fins a quin punt és de flexible i porós l'ordre social i, per tant, quant subjecte està el seu canvi a la voluntat i acció de cadascun dels membres de la comunitat.S'ha visibilitzat també com tot el que es relaciona amb l'emergència és ubicat apart per la societat, sense reconèixer que és una faceta més de la dimensió social, només que des de la vessant opaca i de la que se'n reclama una antropologia que s'hi dediqui. Ans al contrari, es demonitza tot el que s'hi relaciona, ja siguin autors d'emergències, com víctimes de les mateixes o els llocs on aquestes es produeixen i, també, a aquells qui hi estan en contacte, com la policia i els i les agents de policia. A més, aquests són estigmatitzats i ubicats per la majoria en el costat opac i són considerats font de risc, problemes i conflicte en mateixa o semblant mesura a l'emergència i els seus autors. / The collection of emergencies produced in the public space allows to study the fragility of the public order and how strategies are used to controlling and avoiding situations of crisis.The ethnographic work developed picking up this type of emergencies, specially the emergencies approached by the police, has allowed to observe how much the critical emergencies show the risk of fracture, but equally, the effort that the members of the community make for this does not break, and like this to be able to sustain their legitimate expectations towards the attainment of the milestones of their everyday life.Also, through the role of the majority in the face of the emergency, the basic strategies are build around our survival possibilities in the public space, between the rest of the people who wants different thinks in different ways, making possible to understand until which point for the society, how Isaac Joseph quoting in Erving Goffman says, it is more important to reinstate the social order, vehicle and way to be able to continue with what we make, that to halt or to neutralize to the contraveners. However, it is possible to see through the answer of the police in the face of the emergency, the intention of the Power, that founds so much in trying to guarantee these expectations of freedom in our everyday life that the persons require of the responsibles for the social management, as of minimizing the powerful evidence that not even the security is garantible, as well as keep out of sight how much is flexible and porous the social order and, therefore, how much subject its change is on the will and share of each of the members of the community.The research shows also like all what correlates with the emergency is placed aside by the society, without recognizing that a facet is from the social dimension more, if only from the opaque aspect and of the one who an anthropology claims from herself dedicates to it. The fact is that society puts in the same dark hole all what correlates with it, they are already authors of emergencies, like victims of the same ones, or the places where these are produced and, also, to those who they are in touch, like the Police and the police officers.
2

Influência da espessura da camada de opaco na capacidade de mascaramento de metalocerâmicas / Influência da espessura da camada de opaco na capacidade de mascaramento de metalocerâmicas / Capacity opaque masking layer in thicknesses of metal laminated ceramics application / Capacity opaque masking layer in thicknesses of metal laminated ceramics application

PIEPER, Cari Maristela 19 December 2012 (has links)
Made available in DSpace on 2014-08-20T14:30:14Z (GMT). No. of bitstreams: 1 Dissertacao_Cari_Maristela_Pieper.pdf: 422459 bytes, checksum: 06736de352d724ef840d5461683237cd (MD5) Previous issue date: 2012-12-19 / The aim of this study was to evaluate the ability of two ceramic opaque masking applied in different thicknesses in a metallic substrate. 80 Ni-Cr (High Bond) metalic discs were fabricated, each with 1.6 mm diameter and 1 mm thickness, by lost wax technique. After disks obtaining, they were divided into 8 groups (n = 10) and opaque ceramic (Noritake) "paste" (groups 1 to 4) and "powder" (groups 5 to 8) was applied with a camel hair brush and distilled water. The opaque layers were machined with aluminum oxide burs to achieve the following thickness: G1 = G5 and 0.10 mm thick; G2 and G6 = 0.15 mm; G3 and G7 = 0.20 mm and G4 and G8 = 0.30 mm thick. Than opaque dentin ceramic was applied (two sintering cicles, totaling 0.7 mm) and glazed. The color was evaluated with the aid of a portable spectrocolorimeter (Konica - Minolta CR-10), which registered the color of specimens in the CIE L*a*b* scale. The absolute values of L *, a * and b * were statistically analyzed as isolated variables.The &#916;E were also analyzed, considering the mean values of L * a * b * in the control group (G4) as reference values. Once data showed normality and homogeneity, it were applied 2-way ANOVA and Tukey s complementary test, when needed, with p < 5%. Results: Powder opaque presented statistically significant greater values in (L*) and (&#916;E) and the reverse happened to other two variables. Analysing opaque thickness, values may be grouped as followed: (L*) variable: (0,10mm = 0,15mm) < (0,20mm = 0,30mm); (a*) variable: (0,10mm) < (0,15mm = 0,20mm) < (0,30mm); (b*) variable showed no statistically significant differences; (&#916;E) variable: (0,10mm) < (0,15mm = 0,20mm = 0,30mms). It could be concluded that paste and powder opaque have different behavior and all thickness, except 0,10 mm, may be used without significant color change / O objetivo deste estudo foi avaliar a capacidade de mascaramento de duas cerâmicas opacas aplicadas em espessuras diferentes num substrato metálico. Para isso foram confeccionados 80 discos metálicos de Ni-Cr (High Bond) com 16 mm de diâmetro e 1mm de espessura, através da técnica da cera perdida. Após a obtenção dos discos estes foram divididos em 8 grupos (n=10) e foi aplicada a cerâmica opaca (Noritake) em pasta (grupos de 1 à 4) e em pó (grupos de 5 à 8) com pincel de pêlo de camelo e água destilada. As camadas opacas foram usinadas com pontas de óxido de alumínio até atingirem as seguintes espessuras: G1 e G5 = 0,10mm de espessura; G2 e G6 = 0,15mm; G3 e G7 = 0,20mm e G4 e G8 = 0,30mm de espessura. Após, foi aplicada cerâmica de dentina opaca (em dois ciclos de sinterização totalizando 0,7mm), e em seguida à sinterização foi realizado o glaze final.A avaliação da cor foi realizada com o auxílio do Espectrocolorímetro portátil (Konica - Minolta CR-10), que registrou a cor dos 80 corpos de prova metalocerâmicos nos eixos da escala CIE - L*, a* b* após o ciclo de glaze. Os valores absolutos de L*, a* e b* dos grupos foram analisados estatísticamente como variáveis isoladas. Também foi analisado o valor da variável &#916;E, sendo que os valores médios de L* a* e b* do grupo controle (G4) foram considerados como os valores de referência para os cálculos do &#916;a, &#916;b, &#916;L e &#916;E dos demais grupos. Após constatada normalidade e homogeneidade dos dados foi aplicada análise de variância para dois fatores de variação (2-way ANOVA) e teste complementar de Tukey ambos para p<5%. Resultados: O opaco em pó apresentou valores maiores estaticamente significantes nas variáveis (L*) e (&#916;E), ocorrendo o inverso nas outras duas variáveis.Quanto à espessura de opaco, os valores podem ser agrupados da seguinte forma, segundo os testes complementares aplicados: variável (L*): (0,10mm = 0,15mm) < (0,20mm = 0,30mm); variável (a*): (0,10mm) < (0,15mm = 0,20mm) < (0,30mm); variável (b*): não houveram diferenças estatisticamente significantes; variável (&#916;E): (0,10mm) < (0,15mm = 0,20mm = 0,30mm). Conclui-se que houve diferença entre os tipos de opaco em pasta e em pó e que todas as espessuras testadas, exceto a de 0,10 mm, podem ser usadas sem alteração significativa da cor
3

Evidence for partial epithelial-to-mesenchymal transition and recruitment of motile blastoderm edge cells during avian epiboly

Futterman, Matthew 06 June 2011 (has links)
Embryonic epiboly has become an important developmental model for studying the mechanisms underlying collective movements of epithelial cells. In the last couple of decades, most studies of epiboly have utilized Xenopus or zebrafish as genetically tractable model organisms, while the avian epiboly model has received virtually no attention. Here, we re-visit epiboly in quail embryos and characterize several molecular markers of epithelial-to-mesenchymal transition (EMT) in the inner zone of the extraembryonic Area Opaca and at the blastoderm edge. Our results show that the intermediate filament vimentin, a widely-used marker of the mesenchymal phenotype, is strongly expressed in the edge cells compared to the cells in the inner zone, and that epiboly is inhibited when embryos are treated with Withaferin-A, a vimentin-targeting drug. Laminin, an extracellular matrix protein that is a major structural and adhesive component of the epiblast basement membrane, is notably absent from the blastoderm edge, and shows three distinct morphological regions approaching the leading edge. While these expression profiles are consistent with a mesenchymal phenotype, several other epithelial markers, including cytokeratin, β-catenin, and E-cadherin, were present in the blastoderm edge cells. Moreover, the results of a BrDU proliferation assay suggest that expansion of the edge cell population is primarily due to recruitment of cells from the inner zone, and not proliferation. Taken together, our data suggest that the edge cells of the avian blastoderm have characteristics of both epithelial and mesenchymal cells, and could serve as an in-vivo model for cancer and wound healing studies.
4

sanirizaçãp e refrigeração de ovos de codornas comercias contaminados experemente por Salmonella Typhimurium / sanitization and cooling of quail eggs artificially contaminated with Salmonella Typhimurium

LACERDA, Maria Juliana Ribeiro 26 February 2011 (has links)
Made available in DSpace on 2014-07-29T15:07:35Z (GMT). No. of bitstreams: 1 Maria Juliana Lacerda Dissertacao.pdf: 580972 bytes, checksum: afedaefa404680a1d528d495b7558c61 (MD5) Previous issue date: 2011-02-26 / The objective of this study was to verify the physical, chemical and microbiological quality of Japanese quail eggs artificially contaminated with Salmonella Typhimurium, sanitized and stored at different temperatures (between 5 and 25 ºC) for 27 days. We used 768 eggs with opaque shells (Experiment 1) and bright shells (Experiment 2) with typical pigments of the species and average weight of 11 g. The experimental design was completely randomized in a 2x2x2 factorial arrangement (contamination x sanitation x cooling) with six replications, with one egg per experimental unit. The eggs were contaminated by handling with 1.5 x 105 colony forming unit (CFU) of Salmonella Typhimurium / mL and according to the treatments, sanitized with 5ppm Cl a solution, and stored at 5 or 25 ° C. The physical (egg weight, specific gravity, shell thickness, yolk, albumen and shell ratio, Haugh unit, yolk albumen index), chemical (pH of yolk and albumen) and bacteriological (bacterial count in eggshell and egg content) qualities were analyzed. Results of Experiment 1 showed a inear regression of sorage time (P <0.05) of storage time (up to 27 days) worsening the variables of egg weight, albumen and yolk index and albumen ratio. A quadratic effect (p <0.05) of storage time worsening the pH of albumen and Haugh units. There was an interaction for the yolk pH variable between sanitation and refrigeration (p <0.05) after 27 days, while those for non refrigerated eggs the best result was for sanitized eggs, showing the importance of sanitization. In Experiment 2 (eggs with bright shells) there was a linear effect (P <0.05) of storage time (27 days), worsening the variables of egg weight, albumen ratio and Haugh units and quadratic effects (p <0.05) worsening albumen index and pH. These results indicate that eggs with opaque or bright, had a poorer quality with increasing internal storage time, especially at 25 ° C. Quail eggs with opaque or bright shell, stored up to 27 days, should be sanitized (5 ppm of chlorine) and cooled to 5 ° C during storage to maintain physical and chemical qualities, regardless of bacterial contamination. The sanitization (5 ppm Cl) and cooling (5 º C) are effective in reducing the growth of Salmonella in experimentally infected quail eggs. / Objetivou-se com este estudo verificar a qualidade física, química e microbiológica de ovos de codornas japonesas contaminados artificialmente com Salmonella Typhimurium, sanitizados e armazenados a diferentes temperaturas (5 e 25 ºC) durante 27 dias. Foram utilizados 768 ovos com cascas opacas (Experimento 1) e brilhantes (Experimento 2) com pigmentos típicos da espécie e com peso médio de 11 g. O delineamento empregado foi inteiramente casualisados com esquema fatorial 2x2x2 (contaminação x sanitização x refrigeração) com seis repetições, sendo um ovo a unidade experimental. Os ovos foram contaminados pelo manuseio com 1,5 x 105 unidade formadoras de colônias (UFCs) de Salmonella Typhimurium/mL e de acordo com os tratamentos foram sanitizados com solução com 5ppm de Cl e armazenados a 5 ou 25 ºC. Foi analisada a qualidade física (peso do ovo, gravidade específica, espessura de casca, percentagem de gema, albume e casca, unidade Haugh, índices de gema e albume), química (pH de gema e albume) e bacteriológica (contagem de bactérias na casca e no conteúdo do ovo). Os resultados de peso do ovo, uH, índice de gema e de albume e pH de gema e de albume, quando contaminados experimentalmente com Salmonella Typhimurium prejudicou a qualidade física do ovo a partir de 18 dias de armazenamento. Com relação a qualidade bacteriológica do ovo, a sanitização com 5 ppm de Cl pode ser uma alternativa simples e de baixo custo para reduzir a possibilidade de contaminação por Salmonella em ovos de codornas. Pode-se afirmar, que o tempo de estocagem dos ovos e a temperatura de armazenamento influenciaram a qualidade interna dos ovos de codornas em todas as variáveis estudadas. Esses resultados indicam que ovos com cascas opacas ou brilhantes, apresentaram pior qualidade interna com o aumento do tempo de armazenamento, principalmente na temperatura de 25 ºC. Ovos de codornas com casca opaca ou brilhante, armazenados até 27 dias, devem ser sanitizados ( 5 ppm de cloro) e refrigerados a 5 ºC durante a estocagem para manter a qualidade física e química, independentemente da contaminação por bactérias. A sanitização (5 ppm de Cl) e a refrigeração (temperatura de 5 ºC) são eficientes na redução do crescimento da Salmonella em ovos de codornas contaminados experimentalmente.
5

Influência das propriedades térmicas da envolvente opaca no desempenho de habitações de interesse social em São Carlos, SP / Influence of the thermal properties of the opaque envelope in the thermal performance of social housing in São Carlos, SP

Marques, Tássia Helena Teixeira 22 November 2013 (has links)
O objetivo principal desta pesquisa é analisar a influência da transmitância térmica da envolvente opaca (paredes e coberturas) e de outros parâmetros (cor das superfícies exteriores, ventilação natural e inércia térmica) que interferem no desempenho térmico de edifícios habitacionais de interesse social no clima da cidade de São Carlos, SP. Após levantamento de dados em construtoras e em órgãos públicos e privados ligados à habitações, foi selecionado um modelo unifamiliar térreo representativo desta tipologia para a análise. Como a pesquisa baseia-se em simulações paramétricas de desempenho térmico, inicialmente é feito um estudo sobre padrões de modelagem de habitações, identificando quais elementos são mais relevantes. Definidos os parâmetros da modelagem, procede-se à verificação dos valores máximos de propriedades da envoltória prescritos na norma NBR 15575 - Edificações habitacionais - Desempenho, e no regulamento RTQ-R: Regulamento técnico da qualidade para o nível de eficiência energética em edificações residenciais. Esta análise fornece indícios sobre a dificuldade em fixar valores desta propriedade para o fechamento opaco, uma vez que seu desempenho é definido pelas características da envoltória como um todo. Por fim, são realizadas três séries de simulações paramétricas, variando-se a transmitância térmica de paredes e coberturas, a inércia das paredes externas, as cores das superfícies expostas à radiação solar, o aproveitamento de ventilação natural e o uso de cargas internas (ocupação, iluminação e equipamentos). De acordo com os resultados, verifica-se que os melhores desempenhos térmicos estão associados a baixos valores de transmitância da envoltória opaca das habitações. Contudo, percebe-se que as faixas de valores tornam-se muito tênues quando analisa-se o desempenho conjunto dos parâmetros da envoltória. Conclui-se que há uma dificuldade no estabelecimento dos limites de transmitância sem considerar a totalidade de fatores que influem no comportamento térmico da habitação. Isso implica em uma análise conjunta dos materiais de paredes e coberturas e das cores das superfícies exteriores (transmitância, capacidade térmica e absortância). Além disso, critérios que considerem períodos de verão e inverno de acordo com predominância no clima da cidade e ainda outras características, como porcentagem de área envidraçada por orientação de fachada, devem ser considerados nas análises. / The main objective of this research is to analyze the influence of the thermal transmittance of the opaque envelope (walls and roof) and other parameters (color of the exterior surfaces, natural ventilation and thermal mass) that affect the thermal performance of social housing in the city of São Carlos, SP. After a research in public and private agencies related to housing construction, a single-family model was selected for the studies. First, it was carried out a study on parameters of the simulation models, identifying which elements are most relevant for the software. Defined the parameters of the models, it was made a verification of maximum values of properties of the envelope prescribed in the standard NBR 15575 - Residential Buildings - Performance and in the regulation RTQ -R: Technical Regulation for the quality level of energy efficiency in residential buildings. This analysis provides evidence of the difficulty of setting values of this property (U-value) for the opaque envelope, since its performance is defined by the thermal characteristics of the envelope as a whole. Finally, it was made three series of parametric simulations varying the thermal transmittance of walls and roofs, the thermal inertia of the external walls, the colors of the surfaces exposed to solar radiation, the use of natural ventilation and the use of internal loads (occupancy, lighting and equipment). The results indicate that the best performances are associated with low thermal transmittance of the opaque envelope of housing. However, it is clear that the ranges of transmittance values become very tenuous when we analyze the performance of all parameters of the envelope. We conclude that to establish limits of transmittance values results is an incomplete analysis of the thermal performance of the building. It is necessary to consider all factors that influence the thermal behavior of housing, which involves the analysis of the materials of walls and roofs and the colors of exterior surfaces. It is also important to adopt different criteria to consider summer and winter according to predominance in the climate of the city, and to consider in the analysis the percentage of glass area of the exterior envelope.
6

Influência das propriedades térmicas da envolvente opaca no desempenho de habitações de interesse social em São Carlos, SP / Influence of the thermal properties of the opaque envelope in the thermal performance of social housing in São Carlos, SP

Tássia Helena Teixeira Marques 22 November 2013 (has links)
O objetivo principal desta pesquisa é analisar a influência da transmitância térmica da envolvente opaca (paredes e coberturas) e de outros parâmetros (cor das superfícies exteriores, ventilação natural e inércia térmica) que interferem no desempenho térmico de edifícios habitacionais de interesse social no clima da cidade de São Carlos, SP. Após levantamento de dados em construtoras e em órgãos públicos e privados ligados à habitações, foi selecionado um modelo unifamiliar térreo representativo desta tipologia para a análise. Como a pesquisa baseia-se em simulações paramétricas de desempenho térmico, inicialmente é feito um estudo sobre padrões de modelagem de habitações, identificando quais elementos são mais relevantes. Definidos os parâmetros da modelagem, procede-se à verificação dos valores máximos de propriedades da envoltória prescritos na norma NBR 15575 - Edificações habitacionais - Desempenho, e no regulamento RTQ-R: Regulamento técnico da qualidade para o nível de eficiência energética em edificações residenciais. Esta análise fornece indícios sobre a dificuldade em fixar valores desta propriedade para o fechamento opaco, uma vez que seu desempenho é definido pelas características da envoltória como um todo. Por fim, são realizadas três séries de simulações paramétricas, variando-se a transmitância térmica de paredes e coberturas, a inércia das paredes externas, as cores das superfícies expostas à radiação solar, o aproveitamento de ventilação natural e o uso de cargas internas (ocupação, iluminação e equipamentos). De acordo com os resultados, verifica-se que os melhores desempenhos térmicos estão associados a baixos valores de transmitância da envoltória opaca das habitações. Contudo, percebe-se que as faixas de valores tornam-se muito tênues quando analisa-se o desempenho conjunto dos parâmetros da envoltória. Conclui-se que há uma dificuldade no estabelecimento dos limites de transmitância sem considerar a totalidade de fatores que influem no comportamento térmico da habitação. Isso implica em uma análise conjunta dos materiais de paredes e coberturas e das cores das superfícies exteriores (transmitância, capacidade térmica e absortância). Além disso, critérios que considerem períodos de verão e inverno de acordo com predominância no clima da cidade e ainda outras características, como porcentagem de área envidraçada por orientação de fachada, devem ser considerados nas análises. / The main objective of this research is to analyze the influence of the thermal transmittance of the opaque envelope (walls and roof) and other parameters (color of the exterior surfaces, natural ventilation and thermal mass) that affect the thermal performance of social housing in the city of São Carlos, SP. After a research in public and private agencies related to housing construction, a single-family model was selected for the studies. First, it was carried out a study on parameters of the simulation models, identifying which elements are most relevant for the software. Defined the parameters of the models, it was made a verification of maximum values of properties of the envelope prescribed in the standard NBR 15575 - Residential Buildings - Performance and in the regulation RTQ -R: Technical Regulation for the quality level of energy efficiency in residential buildings. This analysis provides evidence of the difficulty of setting values of this property (U-value) for the opaque envelope, since its performance is defined by the thermal characteristics of the envelope as a whole. Finally, it was made three series of parametric simulations varying the thermal transmittance of walls and roofs, the thermal inertia of the external walls, the colors of the surfaces exposed to solar radiation, the use of natural ventilation and the use of internal loads (occupancy, lighting and equipment). The results indicate that the best performances are associated with low thermal transmittance of the opaque envelope of housing. However, it is clear that the ranges of transmittance values become very tenuous when we analyze the performance of all parameters of the envelope. We conclude that to establish limits of transmittance values results is an incomplete analysis of the thermal performance of the building. It is necessary to consider all factors that influence the thermal behavior of housing, which involves the analysis of the materials of walls and roofs and the colors of exterior surfaces. It is also important to adopt different criteria to consider summer and winter according to predominance in the climate of the city, and to consider in the analysis the percentage of glass area of the exterior envelope.

Page generated in 0.0482 seconds