• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 51
  • 44
  • 8
  • 2
  • 1
  • Tagged with
  • 109
  • 109
  • 46
  • 41
  • 32
  • 28
  • 24
  • 23
  • 22
  • 20
  • 18
  • 16
  • 15
  • 15
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

"Estudo dos efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento utilizando-se a técnica MBT" / Study of the effects of active and passive lacebacks in the biomechanics of the leveling phase using the MBT technique

Moresca, Ricardo Cesar 09 June 2006 (has links)
O objetivo deste trabalho foi estudar os efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento, utilizando-se a técnica MBT. A amostra foi constituída de 29 sujeitos de pesquisa (22 do gênero feminino e 7 do gênero masculino), brasileiros, leucodermas e pardos, portadores de má oclusão de Classe I e com idade média de 15 anos e 5 meses. O tratamento ortodôntico foi planejado com as extrações dos primeiros pré-molares e, durante a fase estudada, foram empregados apenas fios de aço inoxidável (0.014", 0.016", 0.018", 0.020" e 0.019" x 0.025"). Os recursos de ancoragem utilizados para os arcos dentários superior e inferior foram, respectivamente, o aparelho extrabucal tipo IHG e o arco lingual fixo. De acordo com a indicação dos lacebacks, a amostra foi dividida em quatro grupos: grupo I – 14 sujeitos que utilizaram lacebacks ativos no arco dentário superior; grupo II – 9 sujeitos que utilizaram lacebacks passivos no arco dentário superior; grupo III – 19 sujeitos que utilizaram lacebacks ativos no arco dentário inferior e grupo IV – 10 sujeitos que utilizaram lacebacks passivos no arco dentário inferior. Para cada indivíduo da amostra foram tomadas duas telerradiografias laterais, uma ao início e outra ao término da fase de nivelamento, com um intervalo médio de 21 meses. Os dados foram coletados utilizando-se o método cefalométrico computadorizado. Para a análise de erros, o método cefalométrico foi repetido em todos os sujeitos da amostra, pelo mesmo operador, com um intervalo mínimo de 15 dias entre as medidas. Os resultados indicaram que as variações observadas foram compatíveis com as estimativas de erros operacionais em estudos cefalométricos. Após a análise estatística e a interpretação dos resultados, verificou-se que, no grupo I, apenas a coroa do primeiro molar superior sofreu um movimento mesial e que tanto a coroa como a raiz do incisivo central superior apresentaram um movimento em direção lingual. No entanto, as inclinações destes dentes não foram alteradas. No grupo II, o primeiro molar superior se manteve estável e somente a coroa do incisivo central superior se movimentou em direção lingual, produzindo uma rotação horária deste dente. No grupo III, observou-se uma mesialização, tanto da coroa como da raiz, e extrusão do primeiro molar inferior, enquanto a posição do incisivo central inferior permaneceu inalterada. As inclinações destes dentes também não foram alteradas. No grupo IV, verificou-se que nem o primeiro molar inferior nem o incisivo central inferior apresentaram variações no sentido ântero-posterior. Verticalmente, houve extrusão apenas do primeiro molar inferior. / The purpose of this study was to evaluate the effects of active and passive lacebacks in the biomechanics of the leveling phase, using the MBT technique. The sample was composed of 29 Brazilian subjects (22 female and 7 male), Caucasian, with Class I malocclusion and mean age of 15 years and 5 months. The orthodontic treatment was planned with the extraction of the first premolars, and the leveling phase was performed with stainless steel wire only (0.014", 0.016", 0.018", 0.020" e 0.019" x 0.025"). The anchorage control devices used in the upper and lower arches were, respectively, the IHG extraoral appliance and the fixed lingual arch. According to the type of laceback prescription, the sample was divided into four groups: group I – 14 subjects in which active lacebacks were used in the upper arch; group II – 9 subjects in which passive lacebacks were used in the upper arch; group III – 19 subjects in which active lacebacks were used in the lower arch; group IV – 10 subjects in which passive lacebacks were used in the lower arch. For each subject of the sample two lateral cephalometric radiographs were taken: one at the beginning and another at the end of the leveling phase, with a mean interval of 21 months. The data were collected using the resources of computerized cephalometry. To perform the analysis of errors, the cephalometric method was repeated in all subjects of the sample, by the same operator, with a minimum interval of 15 days between the measurements. The results revealed that the observed variations were compatible with the estimates of operational errors in cephalometric studies. After statistical analysis and interpretation of the results, it was observed that in group I, only the crown of the upper first molar presented a mesial movement. As to the upper central incisor, both the crown and the root presented a lingual movement. However, the inclination of these teeth was not affected. In group II, the upper first molar remained stable and only the crown of the upper central incisor moved lingually, leading to a clockwise rotation of this tooth. In group III, a mesial movement of both the crown and the root of the lower first molar was observed, along with its extrusion, whereas the position of the lower central incisor remained unchanged. The inclination of these teeth was not affected either. In group IV, it was observed that neither the lower first molar nor the lower central incisor experienced variations in the anteroposterior sense. Vertically, there only was extrusion of the lower first molar.
102

Influence d’un rince-bouche fluoré sur la corrosion galvanique entre un fil NiTi ou un fil CuNiTi et différents boîtiers orthodontiques : incidence sur les propriétés mécaniques des fils

Benguira, David M. 04 1900 (has links)
Objectif : il a été rapporté que l’utilisation d’agents prophylactiques fluorés pouvait favoriser la corrosion galvanique au sein des alliages de titane. L’objectif de la présente étude était d’évaluer l’effet d’un rince-bouche fluoré sur les propriétés mécaniques de fils en nickel-titane (NiTi) et de fils en cuivre-nickel-titane (CuNiTi) lorsque ces derniers sont couplés à des boîtiers de compositions différentes (boîtiers de marques Smartclip, Clarity, et Sprint). Matériels et Méthodes : 90 segments de fils en NiTi et 90 segments de fils en CuNiTi ont été chacun couplés à 2 boîtiers de chaque marque. Chaque assemblage fil-boîtiers a été par la suite incubé pendant 3 heures à 37°C, soit dans une solution de fluore neutre (Fluorinse™ 0,05% NaF), soit dans une solution de salive artificielle (solution contrôle). Suite à l’incubation, les échantillons étaient nettoyés avec de l’eau déshydrogénée, les fils séparés des boîtiers et montés sur un support pour subir un test de pliage en trois points en milieu humide (salive artificielle) à 37°C. Les modules d’élasticité ainsi que les limites conventionnelles d’élasticité en activation et en désactivation ont été mesurés et comparés. Des analyses de Variance (ANOVA) et des comparaisons post-hoc avec la correction de Bonferronni ont été utilisées pour comparer les groupes entre eux (α = 0,05). Résultats : L’utilisation d’un rince-bouche fluoré a produit une réduction du module d’élasticité et de la limite conventionnelle d’élasticité en activation et en désactivation pour les fils en NiTi ; cependant, cet effet a été modulé par le type de boîtier auquel le fil a été couplé. Les propriétés mécaniques de fils en CuNiTi n’ont pas été affectées par le fluor, ou par le type de boîtier utilisé. Conclusions : L’utilisation d’un rince-bouche fluoré modifie les propriétés mécaniques des fils en NiTi seulement. Cet effet est modulé par le boîtier auquel le fil en NiTi est couplé. A la différence des autres études publiées dans la littérature, nos résultats ne nous permettent pas de conclure que la modification des propriétés mécaniques des fils en NiTi entrainerait obligatoirement un allongement de la durée du traitement orthodontique. Mots clés : Fluor, fils nickel-titane, boîtiers orthodontiques, corrosion galvanique, propriétés mécaniques. / Aim: it has been reported that the use of fluoride prophylactic agents can cause galvanic corrosion of the titanium based alloys used in orthodontics. The purpose of the present study was to investigate the effects of a fluoride mouthrinse on the mechanical properties of nickel-titanium (NiTi) and copper–nickel-titanium (CuNiTi) orthodontic archwires that have been coupled with different types of orthodontic brackets (Smartclip, Clarity, and Sprint brackets). Materials and Methods: 90 segments of NiTi and 90 segments of CuNiTi archwires were tested. Every segment was coupled with 2 brackets of each brand. The wire–bracket assembly obtained was incubated, at 37°C for three hours either in a solution of a commercially available mouthwash (Fluorinse™ 0,05% NaF), or in a solution of artificial saliva (control). Following the incubation, the wires were separated from the brackets, rinsed, mounted on a stainless steel support and placed in a waterbath of artificial saliva at 37°C. A 3-point bending test was made to calculate the loading and unloading elastic modulus and yield strength of the wires. Analysis of variance (ANOVA) and post hoc comparisons were made using Bonferronni’s correction to identify the statistically significant differences (α = 0,05). Results: The use of a fluoridated mouthrinse reduced the loading and unloading elastic modulus and yield strength of the NiTi wires. This reduction, however, varies with the type of bracket that was coupled with the wire. The mechanical properties of the CuNiTi wires were not modified by the use of the fluoride rinse or by the type of bracket to which they were coupled. Conclusions : The use of a fluoride mouthrinse alters the mechanical properties of NiTi wires only. This effect varies with the type of bracket that was in contact with the wire. However our results do not allow us to conclude that the alteration of the mechanical properties of the wires would necessarily imply a prolongation of the orthodontic treatment time. Key words: Fluoride, nickel-titanium archwires, galvanic corrosion, mechanical properties,orthodontic brackets.
103

ESTRATÉGIAS PARA A REMOÇÃO DE PIGMENTOS DEPOSITADOS SOBRE BRÁQUETES ESTÉTICOS / STRATEGIES FOR REMOVAL OF PIGMENTS DEPOSITED ON AESTHETIC BRACKETS

Otero, Laura Meireles 25 July 2016 (has links)
The aim of this study was to evaluate the efficiency of cleaning methods in removing pigment deposited on aesthetic brackets, after immersion in coffee. We selected 160 premolar brackets (80 monocrystalline and polycrystalline 80). The brackets were fixed on a glass blade and soon, thereafter, color measurement was performed using a spectrophotometer (T0). For each means of immersion, 80 brackets were selected (40 for each type of ceramic). Soon after staining (30 days of immersion), new color measurements were made (T1). Subsequently, the specimens were divided randomly into four groups for brushing, bleaching, blasting with sodium bicarbonate jet and sodium bicarbonate jet followed by bleaching. New color measurements were made after each cleaning method was used (T2). The color change of the brackets was evaluated according to two formulae, i.e., CIELAB and CIEDE2000. The differences between the average ΔE according to treatment, bracket, and solution were evaluated by linear regression analysis. The greatest staining was caused by coffee. The crystalline structure did not influence the color change. The methods with lower averages of ΔE for coffee were sodium bicarbonate jet followed by bleaching and bleaching, followed by the group that received brushing and sodium bicarbonate jet (both CIELAB as to CIEDE2000). The CIEDE2000 formula was more sensitive in detecting non-acceptable and perceptible differences in color when compared with the CIELAB formula. It was concluded that the most effective methods to remove pigment deposited on aesthetic brackets are sodium bicarbonate jet followed by bleaching and bleaching alone. / O objetivo desse estudo foi avaliar a eficiência dos métodos de limpeza na remoção de pigmentos depositados sobre bráquetes estéticos, após imersão em café. Foram selecionados 160 bráquetes (80 monocristalinos e 80 policristalinos) de pré-molares superiores. Os bráquetes foram fixados em uma lâmina de vidro e logo depois a mensuração de cor foi realizada com um espectrofotômetro (T0). Cada meio de imersão (café ou saliva) continha 80 bráquetes (40 para cada tipo de cerâmica). Logo após a coloração (30 dias de imersão) novas aferições foram feitas (T1). Posteriormente, os espécimes foram divididos randomicamente em 4 grupos: Grupo 1 Escovação; Grupo 2 Clareamento; Grupo 3 Jateamento com bicarbonato de sódio; Grupo 4 Jateamento com bicarbonato de sódio seguido de Clareamento. Novas aferições foram feitas depois de cada método de limpeza (T2). A variação da cor dos bráquetes foi avaliada de acordo com 2 fórmulas: CIELAB E CIEDE2000. As diferenças entre as médias de ΔE de acordo com o tratamento, braquete e solução foram avaliadas através de análise de regressão linear. O café promoveu maior manchamento. A estrutura cristalina não influenciou na alteração de cor. Os métodos com menores médias de ΔE, no café, foram o jateamento com posterior clareamento e o clareamento sozinho, seguido dos grupos que receberam jateamento e escovação (tanto para CIELAB quanto para CIEDE2000). A fórmula CIEDE2000 foi mais sensível em detectar diferenças de cor não-aceitáveis e perceptíveis quando comparado à fórmula CIELAB. Conclui-se que os métodos mais eficazes na remoção de pigmentos depositados sobre bráquetes estéticos são o jateamento com bicarbonato de sódio com posterior clareamento e o clareamento sozinho.
104

"Estudo dos efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento utilizando-se a técnica MBT" / Study of the effects of active and passive lacebacks in the biomechanics of the leveling phase using the MBT technique

Ricardo Cesar Moresca 09 June 2006 (has links)
O objetivo deste trabalho foi estudar os efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento, utilizando-se a técnica MBT. A amostra foi constituída de 29 sujeitos de pesquisa (22 do gênero feminino e 7 do gênero masculino), brasileiros, leucodermas e pardos, portadores de má oclusão de Classe I e com idade média de 15 anos e 5 meses. O tratamento ortodôntico foi planejado com as extrações dos primeiros pré-molares e, durante a fase estudada, foram empregados apenas fios de aço inoxidável (0.014”, 0.016”, 0.018”, 0.020” e 0.019” x 0.025”). Os recursos de ancoragem utilizados para os arcos dentários superior e inferior foram, respectivamente, o aparelho extrabucal tipo IHG e o arco lingual fixo. De acordo com a indicação dos lacebacks, a amostra foi dividida em quatro grupos: grupo I – 14 sujeitos que utilizaram lacebacks ativos no arco dentário superior; grupo II – 9 sujeitos que utilizaram lacebacks passivos no arco dentário superior; grupo III – 19 sujeitos que utilizaram lacebacks ativos no arco dentário inferior e grupo IV – 10 sujeitos que utilizaram lacebacks passivos no arco dentário inferior. Para cada indivíduo da amostra foram tomadas duas telerradiografias laterais, uma ao início e outra ao término da fase de nivelamento, com um intervalo médio de 21 meses. Os dados foram coletados utilizando-se o método cefalométrico computadorizado. Para a análise de erros, o método cefalométrico foi repetido em todos os sujeitos da amostra, pelo mesmo operador, com um intervalo mínimo de 15 dias entre as medidas. Os resultados indicaram que as variações observadas foram compatíveis com as estimativas de erros operacionais em estudos cefalométricos. Após a análise estatística e a interpretação dos resultados, verificou-se que, no grupo I, apenas a coroa do primeiro molar superior sofreu um movimento mesial e que tanto a coroa como a raiz do incisivo central superior apresentaram um movimento em direção lingual. No entanto, as inclinações destes dentes não foram alteradas. No grupo II, o primeiro molar superior se manteve estável e somente a coroa do incisivo central superior se movimentou em direção lingual, produzindo uma rotação horária deste dente. No grupo III, observou-se uma mesialização, tanto da coroa como da raiz, e extrusão do primeiro molar inferior, enquanto a posição do incisivo central inferior permaneceu inalterada. As inclinações destes dentes também não foram alteradas. No grupo IV, verificou-se que nem o primeiro molar inferior nem o incisivo central inferior apresentaram variações no sentido ântero-posterior. Verticalmente, houve extrusão apenas do primeiro molar inferior. / The purpose of this study was to evaluate the effects of active and passive lacebacks in the biomechanics of the leveling phase, using the MBT technique. The sample was composed of 29 Brazilian subjects (22 female and 7 male), Caucasian, with Class I malocclusion and mean age of 15 years and 5 months. The orthodontic treatment was planned with the extraction of the first premolars, and the leveling phase was performed with stainless steel wire only (0.014”, 0.016”, 0.018”, 0.020” e 0.019” x 0.025”). The anchorage control devices used in the upper and lower arches were, respectively, the IHG extraoral appliance and the fixed lingual arch. According to the type of laceback prescription, the sample was divided into four groups: group I – 14 subjects in which active lacebacks were used in the upper arch; group II – 9 subjects in which passive lacebacks were used in the upper arch; group III – 19 subjects in which active lacebacks were used in the lower arch; group IV – 10 subjects in which passive lacebacks were used in the lower arch. For each subject of the sample two lateral cephalometric radiographs were taken: one at the beginning and another at the end of the leveling phase, with a mean interval of 21 months. The data were collected using the resources of computerized cephalometry. To perform the analysis of errors, the cephalometric method was repeated in all subjects of the sample, by the same operator, with a minimum interval of 15 days between the measurements. The results revealed that the observed variations were compatible with the estimates of operational errors in cephalometric studies. After statistical analysis and interpretation of the results, it was observed that in group I, only the crown of the upper first molar presented a mesial movement. As to the upper central incisor, both the crown and the root presented a lingual movement. However, the inclination of these teeth was not affected. In group II, the upper first molar remained stable and only the crown of the upper central incisor moved lingually, leading to a clockwise rotation of this tooth. In group III, a mesial movement of both the crown and the root of the lower first molar was observed, along with its extrusion, whereas the position of the lower central incisor remained unchanged. The inclination of these teeth was not affected either. In group IV, it was observed that neither the lower first molar nor the lower central incisor experienced variations in the anteroposterior sense. Vertically, there only was extrusion of the lower first molar.
105

Protótipo de ponteira acoplada aos aparelhos fotopolimerizadores para colagem de bráquetes e acessórios ortodônticos

Mota Júnior, Sergio Luiz 14 February 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-18T14:18:46Z No. of bitstreams: 1 sergioluizmotajunior.pdf: 65970440 bytes, checksum: b08afa740679beb93b85550945b417d2 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-01T18:47:10Z (GMT) No. of bitstreams: 1 sergioluizmotajunior.pdf: 65970440 bytes, checksum: b08afa740679beb93b85550945b417d2 (MD5) / Made available in DSpace on 2016-07-01T18:47:10Z (GMT). No. of bitstreams: 1 sergioluizmotajunior.pdf: 65970440 bytes, checksum: b08afa740679beb93b85550945b417d2 (MD5) Previous issue date: 2012-02-14 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do presente estudo foi o desenvolvimento de uma nova ponteira para ser acoplada aos aparelhos fotopolimerizadores utilizados para colagem de bráquetes e acessórios ortodônticos, e teste da efetividade da mesma em ensaio mecânico in vitro. A ponteira é espelhada na superfície interna e baseia-se em conceitos físicos de refração e reflexão de luz. Apresenta como principal vantagem, a redução do tempo clínico necessário para o procedimento de colagem, reduzindo, dessa forma, a possibilidade de contaminação durante o processo. Através do ensaio de resistência mecânica ao cisalhamento e da determinação do Indice Remanescênte de Adesivo (IRA), testou-se a ponteira em uma amostra composta por 120 corpos de prova, sendo a mesma dividida em 2 grupos. No grupo 1 foi utilizado aparelho fotopolimerizador de fonte de luz halógena e no grupo 2 foi utilizado fonte de LED. Cada grupo foi subdividido. Nos subgrupos H1 e L1 utilizou-se a ponteira convencional dos respectivos instrumentos. Nos subgrupos H2 e L2 a colagem foi feita utilizando-se a ponteira desenvolvida. Os valores dos testes de cisalhamento e IRA para os subgrupos foram comparados entre si. Os resultados mostraram que não houve diferença estatisticamente significante, tanto para os ensaios de resistência ao cisalhamento (p>0,05), quanto para o IRA (p>0,05) entre os subgrupos. Conclui-se que 1 - os testes de ensaios mecânicos, assim como a análise do IRA mostraram que a nova ponteira desenvolvida, cumpriu os requisitos necessários à colagem dos acessórios ortodônticos; 2 – o tempo de colagem foi reduzido pela metade, sendo necessária uma só incidência. / The porpose of the present study was the development of a new device to be coupled to light-curing units for bonding orthodontic brackets and accessories and test of its efficacy in “in vitro” mechanical trial. The inner surface of the device is mirrored and is based on physical concepts of light refraction and reflection. The main advantage of such device is the reduced clinical time needed for bonding and the lesser possibility of contamination during the process. 120 bodies of proof were used for testing the shear bond strength of brackets bonded with the device. The Adhesive Remnant Index (ARI) was also determined. The sample was divided into 2 groups. In group 1 a halogen light-curing unit was used and in group 2 a led lightcuring unit was used. Each group was then subdivided. In subgroups H1 and L1, a conventional light guide rod was used. In subgroups H2 and L2 bonding was performed with the mirrored device coupled to the tip of the guide light rod. The values obtained for the shear bond strength and the ARI in the subgroups were compared. Results showed that there was no statistically significant difference for the shear strength (p>0,05) and the ARI (p>0,05) between the subgroups. Conclusions are that 1 - The tests of mechanical trials and the ARI analysis showed that the new device fulfilled the requisites for bonding orthodontic accessories; 2 - time for bonding was reduced to half, being necessary only one light exposure.
106

Efeito de cobertura antiaderente no acúmulo de biofilme em dispositivos ortodônticos / Effect of accumulation of coverage nonstick biofilm on orthodontic brackets

Oliveira, Adauê Siegert de 01 June 2012 (has links)
Made available in DSpace on 2014-08-20T14:30:05Z (GMT). No. of bitstreams: 1 tese_Adaue_banca.pdf: 296840 bytes, checksum: 0cd98d8b2ca7a1306c82e4b8319d9e71 (MD5) Previous issue date: 2012-06-01 / The use of orthodontic devices has been associated with an increase in dental biofilm retention. In this study, the effect of hydrophobic coatings, based on (fluorinated or not) organo-silanes, on the reduction of the contact angle and early biofilm retention in orthodontic devices was tested. Two different types of hydrophobic were tested: hydrophobic solution 1 (SH1), obtained by dilution of 2.5% of hexadecyl-triethoxy-silane in ethanol, and hydrophobic solution 2 (SH2), composed of 2.5% of perfluorodecyl-triethoxy-silane diluted in dimethyl sulfoxide. The solutions were applied in ceramic and stainless steel substrates and, via sol-gel process and crosslinking, siloxane networks were formed on the surface of the devices. The effect of the coatings was evaluated in two stages. In the first stage, aiming the characterization of the surface, the water contact angle was analyzed. Stainless steel and polycrystalline alumina plates were prepared, previously applying or not alumina sandblasting as surface treatment. A significant increase in contact angle was observed with the application of both hydrophobic solutions in both substrates, with the sandblasting allowing formation of super-hydrophobic surface in the ceramic substrate (contact angle up to 155o), while hydrophobic surfaces were obtained in the steel substrate (contact angle up to 123o). In the second phase, the effect of the hydrophobic coating on the biofilm retention in orthodontic brackets was evaluated using a microscosm model. Orthodontic brackets were previously prepared according to the surface treatments that showed the best results in the phase 1 (SH1 for steel, SH2 for ceramic). The effect of the coatings on the biofilm formation was evaluated in periods of 12h and 24h (controls: uncoated substrates and sandblasted substrates). The results showed that the hydrophobic coatings did not result in significant effect in biofilm retention for the time 12h, whereas all coating treatments significantly reduced the biofilm retention in the metal and ceramic brackets compared with the control groups. A significant exponential reduction in biofilm retention at 24h was associated with the increase in contact angle. It can be concluded that application of (super)-hydrophobic crosslinked coatings via sol-gel process on the surface of orthodontic metal and ceramic brackets reduced the surface wetting of the surfaces in contact with water and had a significant effect on the retention of dental biofilm after 24h / O uso de dispositivos ortodônticos tem sido associado ao aumento da retenção de biofilme dentário. Neste estudo, foi testado o efeito de coberturas hidrófobas,baseadas em organo-silanos (flourados ou não), no aumento do ângulo de contato e redução de acúmulo de biofilme inicial em dispositivos ortodônticos. Dois tipos diferentes de soluções hidrófobas foram testadas: solução hidrófoba 1 (SH1), obtida pela diluição de 2,5% de hexadecil-trietóxi-silano em etanol, e solução hidrófoba 2 (SH2), composta por 2,5% de perfluorodecil-trietóxi-silano diluído em dimetilsulfóxido. As soluções foram aplicadas em substratos cerâmico e de aço inox e, via processo sol-gel e reticulação, foram formadas redes siloxanas na superfície dos dispositivos. O efeito das coberturas foi avaliado em duas etapas. Na primeira etapa, buscando a caracterização da superfície, foi analisado o ângulo de contato com água. Placas de aço inox e alumina policristalina foram preparadas, aplicando ou não jateamento prévio das superfícies com partículas de alumina. Foi observado aumento significativo do ângulo de contato com a aplicação das duas soluções hidrófobas em ambos substratos, sendo que o jateamento do substrato propiciou a formação de superfície superhidrófoba no substrato cerâmico (ângulo de contato de até 155o), enquanto superfícies hidrófobas foram obtidas no substrato aço (ângulo de contato até 123o). Na segunda fase do trabalho, avaliou-se o efeito da cobertura no acúmulo de biofilme em braquetes ortodônticos, através de modelo de microcosmos. Braquetes ortodônticos foram previamente preparados conforme os tratamentos de superfície que apresentaram melhores resultados na primeira fase (SH1 para aço, SH2 para cerâmica). Foi avaliado o efeito da cobertura na formação de biofilme em períodos de 12h e 24h (controles: substratos não-recobertos e substratos jateados). Os resultados mostraram que as coberturas hidrófobas não resultaram em efeito significativo no acúmulo de biofilme no tempo 12h, entretanto todos os tratamentos de cobertura reduziram de forma significativa o acúmulo de biofilme sobre os braquetes metálicos e cerâmicos comparados aos grupos controle no período 24h. Foi observada relação de redução exponencial significativa entre ângulo de contato e acúmulo de biofilme para o tempo 24h. Dessa forma, conclui-se que a aplicação de coberturas (super)-hidrófobas reticuladas via processo sol-gel na superfície de dispositivos ortodônticos metálicos e cerâmicos reduziu o molhamento das superfícies em contato com a água e teve efeito significativo na retenção de biofilme bucal sobre esses dispositivos após 24h
107

Análise dentária tridimensional em pacientes biprotrusos submetidos a extrações de primeiros pré-molares /

Cunha, Anderson Farias da January 2018 (has links)
Orientador: Luiz Gonzaga Gandini Júnior / Resumo: Objetivo: Avaliar as alterações dentárias em indivíduos biprotrusos submetidos a extração dos quatro primeiros pré-molares. Materiais e métodos: A amostra constituise de 50 pacientes adultos Classe I de Angle, biprotrusos, com apinhamento até 4mm por arco dentário e com necessidade de extração de quatro primeiros pré-molares, que foram randomizados em 2 técnicas de tratamento: a retração em massa (n = 25) e a retração em duas etapas (n = 25, cada paciente teve colado um braquete convencional ou autoligado em cada canino de forma aleatória). Foram usados modelos digitais obtidos antes, um, dois e três meses após o início da retração dos caninos, e após o fechamento dos espaços das extrações. Foram avaliados a inclinação, angulação e rotação dos caninos (durante a retração dos caninos), e a rotação dos primeiros molares superiores (na retração em massa ou duas etapas). Resultados: Nenhuma diferença foi encontrada entre a técnica de retração ou tipo de braquete. Conclusão: Conclui-se que não houve diferença na angulação, inclinação e rotação entre os braquetes convencionais ou autoligados, além disso a rotação dos molares foi similar na retração em massa e duas etapas. / Abstract: Objetive: To evaluate the dental changes in patients bimaxillary protrusion with firstpremolar extraction. Methods: Fifty adults patients Class I malocclusion, dentalprotrusion, arch length discrepancy bellow for 4mm, and need for first premolarextractions were randomized to 2 treatment techniques: en-mass retraction (n = 25)and two-steps retraction (n = 25, patients had either conventional or self-ligatingbrackets bonded to canines randomly). Digital models before, and one, two, threemonths after starting the canine retraction, and after the closing of space. Wereevaluated the canine inclination, angulation and rotation (canine retraction), androtation of the upper first molars (en-mass or two-steps retraction). Results: Nodifferences were found between retraction techniques or the type of bracket.Conclusions: Angulation, inclination and rotation showed no diferences betweenconventional or self-ligating brackets, besides that the rotation molar was similar in enmassor two-steps retraction. / Mestre
108

EFEITO DA DENSIDADE DE ENERGIA DE FOTOATIVADORES DE ALTA POTÊNCIA NAS PROPRIEDADES FÍSICO-MECÂNICAS DE UMA RESINA ORTODÔNTICA

Arana, Andrés Fernando Montenegro 16 October 2017 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-03-01T13:44:47Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Andrés Fernando Montenegro.pdf: 11976346 bytes, checksum: fa909dec838336e8c5a4ed73180bb65b (MD5) / Made available in DSpace on 2018-03-01T13:44:47Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Andrés Fernando Montenegro.pdf: 11976346 bytes, checksum: fa909dec838336e8c5a4ed73180bb65b (MD5) Previous issue date: 2017-10-16 / O objetivo deste estudo foi verificar o efeito da densidade de energia e o tempo de exposição de fotopolimerizadores LED de terceira geração em uma resina ortodôntica disponível comercialmente nos valores de microdureza, cisalhamento, índice de remanescente de resina e grau de conversão. Para tanto, foram realizados 3 experimentos: Experimento 1, o objetivo foi avaliar o grau de conversão (DC) e microdureza vickers (MHV) da resina ortodôntica utilizando dois LEDs de terceira geração, assim como, protocolos de fotoativação diferentes. Foram necessários 80 brackets cerâmicos e 80 brackets metálicos, sendo divididos em 16 grupos experimentais (n=10) tendo os seguintes grupos para cada LED: um grupo controle, diminuição da metade do tempo de exposição do grupo controle, um quarto do tempo do grupo controle, função turbo ou plasma para os LEDs Bluephase e Valo, respetivamente. Imediatamente após a polimerização, foram realizados os ensaios de DC e MHV. O experimento 2, objetivou verificar a influência de diferentes densidades de energia emitidas por dois fotoativadores LED de alta potência nas propriedades físicas e mecânicas de uma resina ortodôntica em brackets metálicos. Foram necessários 80 pré-molares superiores, sendo usadas as superfícies vestibulares dos dentes para a colagem dos 80 brackets metálicos. Os dentes foram divididos aleatoriamente em 8 grupos experimentais (n=10), sendo: um grupo controle, redução da metade do tempo de exposição do grupo controle, um quarto do tempo do grupo controle, função plasma ou turbo para cada LED estudado, sendo Valo e Bluephase. Após 24 horas da polimerização, foram realizados os testes de cisalhamento (SBS), índice remanescente de resina (ARI) e MHV. O objetivo do experimento 3 foi verificar a influência de diferentes densidades de energia depositadas por dois fotoativadores LED diferentes de alta potência nas propriedades físicas e mecânicas de uma resina ortodôntica em brackets cerâmicos. Foram necessários 80 dentes pré-molares superiores hígidos, sendo utilizadas as superfícies linguais ou palatinas dos dentes para colagem dos 80 brackets cerâmicos. Os dentes foram divididos aleatoriamente em 8 grupos experimentais (n=10), foram formados grupos iguais para cada LED Valo e Bluephase: um grupo controle, diminuição da metade do tempo de exposição do grupo controle, um quarto do tempo do grupo controle, função turbo do LED Bluephase ou plasma do LED Valo. Após 24 horas da polimerização, foram realizados os testes de SBS, ARI e MHV. Os resultados de cada experimento foram analisados através de testes estatísticos específicos, para determinar se houve ou não diferença estatisticamente significativa. Para o experimento 1 foram realizados ANOVA de duas vias e teste de Tukey (α=0,05), para o experimento 2 e 3 foram realizados Anova de duas vias com testes de Tukey (α=0,05). O experimento 1 mostrou que os grupos dos brackets cerâmicos tem baixa variação, porém pequenas mudanças no aumento dos valores da energia aplicada em Joules totais aumentam os valores de DC e MHV, nos brackets metálicos pelo fato de impedir a passagem da luz o DC e HVK diminuem significativamente, permanecendo dentro dos parâmetros considerados normais. O experimento 2 mostrou que ambos LED utilizados foram efetivos tanto na função standard como na turbo ou plasma, sendo que as funções turbo ou plasma ofereceram resultados similares aos do controle, efetivando mesmo com a redução do tempo para a polimerização dos brackets metálicos. No experimento 3 não houve diferença estatisticamente significativa nos grupos analisados. Os LEDs estudados proporcionaram valores suficientes de Joules em alguns grupos experimentais sendo este suficiente para atingir bons valores no DC, SBS e MHV. O uso de LEDs com uma potência adequada, sendo o mínimo de 1200 mW/cm2, ou o uso de uma potência elevada de entre 2400 a 3200 mW/cm2 e um curto período de tempo de exposição entre 3 a 6 segundos, são efetivos para a colagem de acessórios ortodônticos. / The objective of this study was to verify the effect of energy density and the time of exposure of third generation LED light curing agents on a commercially available orthodontic resin in the values of microhardness, shear, resin remaining index and degree of conversion. Three experiments were carried out: Experiment 1, the objective was to evaluate the degree of conversion (DC) and microhardness vickers (MHV) of the orthodontic resin using two third generation LEDs, as well as different photoactivation protocols. 80 ceramic brackets and 80 metallic brackets were required and divided into 16 experimental groups (n=10), with the following groups for each LED: control group, one half, one quarter of the control group time, turbo or plasma function for the Bluephase and Valo LEDs, respectively. Immediately after the polymerization, the DC and MHV assays of the specimens were performed. The experiment 2, aimed to verify the influence of different energy densities emitted by two high power LED photoactivators on the physical and mechanical properties of an orthodontic resin in metallic brackets. For this experiment, 80 carious cavity-free, superior human premolar teeth were used, and the buccal surfaces of the teeth were used for the bonding of the 80 metal brackets. The teeth were randomly divided into 8 experimental groups (n=10), with the following groups being a control group, half the time of exposure of the control group, one quarter of the time in the control group, plasma or turbo function for each LED studied, being Valo and Bluephase. After polymerization, the teeth and specimens were stored 24h at 37°C to perform the shear tests (SBS), resin remaining index (ARI) and MHV. The objective of experiment 3 was to verify the influence of different energy densities deposited by two different LED light-curing on the physical and mechanical properties of an orthodontic resin in ceramic brackets. For this experiment, it was necessary to have 80 carious free upper premolar human teeth, using the lingual or palatine surfaces of the teeth for bonding the 80 ceramic brackets. The teeth were randomly divided into 8 experimental groups (n=10), equal groups were formed for each Valo and Bluephase LEDs: one control group, one half-time control group exposure time, one-fourth time control group, function LED Bluephase turbo or LED Valo Plasma. After polymerization, the teeth and specimens were stored 24 hours at 37°C to perform the SBS, ARI and MHV tests. The results of each experiment were analyzed by specific statistical tests to determine whether or not there was a statistically significant difference. For experiment 1, 2 and two-way ANOVA and Tukey's test (α=0.05) were performed. Experiment 1 showed that the groups of ceramic brackets have low variation, but small changes in the increase of the values of the applied energy in total Joules increase the values of DC and MHV in the metallic brackets because it prevents the passage of light the DC and HVK decrease significantly, remaining within the parameters considered normal. Experiment 2 showed that both LEDs were effective both in the standard function and in the turbo or plasma, and the turbo or plasma functions gave similar results to the control, even effecting with the reduction of the time for the polymerization of the metal brackets. In the experiment 3 there was no statistically significant difference in the analyzed groups. The studied LEDs provided sufficient values of Joules in some experimental groups being sufficient to reach good values in DC, SBS and HVK. The use of LEDs with adequate power, being at least 1000 mW/cm2, or the use of a high power of between 2400 and 3200 mW/cm2 and a short period of exposure of between 3 to 6 seconds, are sufficient for the bonding of orthodontic accessories.
109

Prevalencija početnih karijesnih lezija i mogućnosti njihove terapije nakon fiksnog ortodontskog tretmana / The prevalence of initial carious lesions and the possibility of their therapy after fixed orthodontic treatment

Demko Rihter Ivana 12 September 2018 (has links)
<p>UVOD Početne karijesne lezije gleđi (bele mrlje) se defini&scaron;u kao područija demineralizovane gleđi, koja nastaju kao posledica neadekvatnog higijensko-dijetetskog režima. Prevencija belih mrlja je neophodna, kako bi se dobio maksimalan učinak terapije fiksnim ortodontskim aparatima. U prevenciji i terapiji belih mrlja se primenjuju preparati na bazi kazein- fosfopeptid &ndash; amorfnog kalcijum fosfata (CPP-ACP) i preparati na bazi fluorida. Ciljevi istraživanja su bili da se ispita prisustvo početnih karijesnih lezija gleđi, nakon tretmana fiksnim ortodontskim aparatima i da se istraži uspe&scaron;nost terapije početnih karijesnih lezija gleđi. MATERIJAL I METODE RADA U studiju je bilo uključeno 100 pacijenata, uzrasta od 15-50 godina, kod kojih je indikovana terapija fiksnim ortodontskim aparatima na Klinici za stomatologiju Vojvodine. Pacijenti su bili podeljeni u dve grupe, eksperimentalnu (pacijenti koji su koristili preparate na bazi kazein- fosfopeptid &ndash; amorfnog kalcijum fosfata i standardne preparate za oralnu higijenu) i kontrolnu (koji su koristili samo standardne preparate za oralnu higijenu). Analizirane su fotografije pacijenata napravljene pre početka tretmana, nakon uklanjanja fiksnih ortodontskih aparata i nakon terapije početnih karijesnih lezija. Formirana je baza podataka, koja je bila kori&scaron;ćena za potrebe ovog istraživanja, u okviru &bdquo;Onyxceph&ldquo; softverskog programa. U istraživanju se koristio upitnik, sastavljen većinom od pitanja zatvorenog tipa. REZULTATI Rezultati istraživanja pokazuju da je većina ispitanika bila ženskog pola (68%). Početne karijesne lezije su bile če&scaron;će dijagnostikovane kod mu&scaron;kog pola. Najveći broj pacijenata je bio iz grupe mlađeg odraslog doba (42%) i adolescenata (32%). Kod 73% pacijenata, koji su pro&scaron;li tretman fiksnim ortodontskim aparatima, dijagnostikovane su početne karijesne lezije zuba na kraju tretmana. Pacijenti koji su vi&scaron;e puta u toku dana konzumirali konditorske proizvode, u toku ortodontskog tretmana, su imali najvi&scaron;i procenat belih mrlja (87,5%). ZAKLJUČCI Potvrđene su obe hipoteze: 1. Prevalencija početnih karijesnih lezija gleđi nakon fiksne ortodontske terapije bila je vi&scaron;a od 60%, kod pacijenata koji su minimum godinu dana nosili fiksni ortodontski aparat. 2. Terapija belih mrlja preparatima Tooth Mousse (CPP-ACP) je dala značajno bolje rezultate, u odnosu na grupu ispitanika koji su koristiti samo standardna sredstva za održavanje oralne higijene. Na osnovu dobijenih rezultata kliničkih istraživanja može se zaključiti da je prevalencija početnih karijesnih lezija gleđi proporcionalno veća kod pacijenata koji su imali slabiju oralnu higijenu u toku ortodontskog tretmana, u poređenju sa pacijentima koji su imali visoku svest o važnosti higijensko-dijetetskog režima. Primena Tooth Mousse pasta u tretmanu početnih karijesnih lezija gleđi od značajne je važnosti za remineralizaciju zubne gleđi. Dužina trajanja ortodontskog tretmana nije dovedena u direktnu vezu sa pojavom početnih karijesnih lezija gleđi.</p> / <p>INTRODUCTION The initial carious lesions (white spots) indicate an area of demineralization of enamel as a result of an inadequate hygiene-dietary regime. The prevention of white spots lesions (WSL) is necessary in order to obtain the maximum effect of the therapy with fixed orthodontic appliances. In the prevention and treatment of white spots, products based on casein-phosphopeptide-amorphous calcium phosphate (CPP-ACP) are applied as well as preparations based on fluoride. The aims of the study were to examine the presence of initial carious lesions on the surface of the tooth after treatment with fixed orthodontic appliances and to assess the success of the therapy of initial caries lesions. MATERIAL AND METHODS The study included 100 patients aged 15-50 who were treated with fixed orthodontic appliances, at the public Dentistry Clinic of Vojvodina. Patients were divided into two groups: experimental (patients who used Tooth Mousse paste and standard oral hygiene products) and control group (using only standard oral hygiene products). The photos of patients were made and analyzed in three stages of the study - before the beginning of the treatment, after the removal of fixed orthodontic appliances and after the therapy of initial caries lesions. Using the &quot;Onyxceph&quot; software program, the database was created, which was used for the purposes of this research. The questionnaire composed mostly of close-ended questions was used for the purpose of this survey. RESULTS The restates of this study indicated that a majority of respondents were female. (68%). The initial carious lesions were more commonly diagnosed in men. The majority of patients with WSL were in group of young adult people (42%) and adolescents (32%). In 73% of all patients who were treated with fixed orthodontic appliances, were diagnosed WSL on the end of the orthodontic treatment. Patients who consumed confectionery products several times during the day, during the orthodontic treatment, had the highest percentage of white spots lesions (87.5%). CONCLUSION Both hypotheses have been confirmed: 1.The prevalence of initial carious lesions of the tooth enamel after fixed orthodontic therapy was higher than 60% in patients who had fixed orthodontic appliances for at least a year. 2. White spot therapy with Tooth Mousse&#39;s products showed significantly better results compared to a group of subjects who only used standard oral hygiene products. On the basis of the obtained results of clinical trials, it can be concluded that the prevalence of initial caries lesions is proportionally greater in patients with lower oral hygiene during orthodontic treatment, compared to patients who had higher awareness of the importance of the hygiene-dietary regime. The use and application of Tooth Mousse paste in the treatment of initial carious lesion is vital for the re-mineralization of the enamel surface.</p>

Page generated in 0.0593 seconds