• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • 4
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 38
  • 15
  • 8
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

A Study on the Design of Auxiliary Walking Mechanisms for Lower Limb Disablement

Chen, Yu-ting 08 September 2006 (has links)
Orthoses and auxiliaries are important to the people with lower limb disabled in their daily lives. The purpose of this study is to survey and discuss the existing walking auxiliary mechanism for the lower limb disabled people, and to design a new walking auxiliary mechanism to improve their walking gesture. In order to develop a new auxiliary mechanism for the people with lower limb disabled, commercial orthoses and patents are colleted, analyzed, classified, and compared to each others. Several interviews with a lower limb disablement are arranged and understand what they need. After integrating all the collected information as the design input, theories of mechanism structure synthesis, dimension synthesis, mechanism analysis are utilized to develop a mechanism design of auxiliary for lower limb disabled people to walk, to go up and down the stair. The Pro-Engineering, a CAD software, is used for solid modeling and the Visual Nastran, a CAE software, is applied for motion simulation. The results of computer simulations of walking and climbing up stairs are compared to that of video taken from the interviewed people.
12

Análise cinética e cinemática da marcha de indivíduos paraplégicos com e sem órtese de pé e tornozelo (AFO) / Kinematic and kinetic gait assessment of paraplegic patients with and without ankle foot orthosis (AFO)

Azevedo, Eliza Regina Ferreira Braga Machado de 04 January 2011 (has links)
Orientador: Alberto Cliquet Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-18T00:27:16Z (GMT). No. of bitstreams: 1 Azevedo_ElizaReginaFerreiraBragaMachadode_M.pdf: 1886152 bytes, checksum: 31a1a8c8021802be56436a5b3e121a0b (MD5) Previous issue date: 2011 / Resumo: A lesão medular tem como consequência a perda da mobilidade e sensibilidade abaixo do nível da lesão, gerando, portanto, a impossibilidade de andar. Essa perda de movimentos traz inúmeras consequências aos pacientes lesados medulares como osteoporose, atrofia muscular, espasticidade, infecções urinárias de repetição entre outras. E muitas destas consequências podem ser minimizadas com o treinamento de marcha realizado com a utilização de estimulação elétrica neuromuscular (EENM). Dessa forma, o objetivo da pesquisa foi descrever a marcha de paraplégicos completos utilizando EENM e avaliar os efeitos da ankle foot orthoses (AFO) do tipo rígida na marcha destes indivíduos. Dezesseis indivíduos, sendo dez participantes controle e seis paraplégicos completos realizaram avaliação cinética e cinemática da marcha com e sem AFO. Ambos os grupos realizaram as avaliações em duas etapas: com AFO e sem AFO. Sendo que o grupo de pacientes realizou a marcha sempre utilizando EENM nos músculos quadríceps e no nervo fibular. Foi utilizado sempre o mesmo calcado durante os testes. Foram utilizados como parâmetros espaço-temporais a velocidade média (m/s), a cadência (passos/min), o comprimento de passo (m) e a porcentagem da fase de apoio. Todas as variáveis apresentaram diferenças significativas entre grupos e uso ou não da AFO, com exceção da porcentagem da fase de apoio, que apenas apresentou diferença entre os grupos (p<0,001). Entre as variáveis cinemáticas do tornozelo no contato inicial houve diferença entre os grupos (p=0,026), na amplitude de movimento (ADM) no apoio a diferença foi significativa no uso ou não da AFO (p=0,01), entre grupos (p=0,02) e na interação entre os grupos e o uso ou não da AFO (p=0,008), e na ADM no balanço a diferença ocorreu entre o uso e não da AFO (p=0,002) e na interação entre grupos e uso ou não da AFO (p=0,007). As variáveis do joelho que apresentarão valores significativos entre o uso ou não da AFO foram o ângulo no contato inicial (p=0,002), a ADM no apoio (p=0,0001) e a flexão no impulso (p=0,018), entre os grupos a flexão no impulso (p<0,0001) e a máxima flexão no balanço (p<0,001) apresentaram valores significativos. No quadril as diferenças significativas ocorreram apenas entre os grupos para o contato inicial (p<0,0001), máxima extensão no apoio (p=0,002), a extensão no impulso (p=0,005) e a máxima flexão no balanço (p=0,001). Nas variáveis cinéticas do tornozelo foram avaliados o momento no choque de calcanhar e momento máximo flexor plantar, ambos apresentaram valores significativos entre grupos (p=0,012 e p=0,014) e apenas o momento no choque de calcanhar apresentou diferença entre o uso ou não da AFO (p=0,015). No joelho e quadril foram avaliados os momentos máximos flexor e extensor. Sendo que no joelho apenas o máximo momento extensor apresentou diferença entre os grupos (p=0,0002). No quadril os valores de momento flexor máximo foram significativos entre grupos (p<0,0001). Os resultados espaço-temporais sugerem que a marcha com AFO é mais eficaz para os paraplégicos completos. Além disso, a AFO promoveu uma maior proteção ao joelho do desses indivíduos e permitiu uma maior descarga mecânica no quadril podendo assim, prevenir a perda de massa óssea / Abstract: The spinal cord injury leads to the loss of mobility and sensibility below the injury level, causing the inability to walk. This loss of movement causes consequences for spinal cord injured patients such as osteoporosis, muscle atrophy, spasticity, repetitive urinary infections and others. Many of these consequences can be minimized by gait training with neuromuscular electrical stimulation (NMES). Thus, the objective of the research was to describe paraplegic gait with NMES and assess the influence of rigid AFO on these individuals gait. Sixteen individuals, ten control participants and six complete paraplegics went through kinetics and kinematics gait evaluation with and without AFO. The patients group performed the gait using NMES in quadriceps muscles and peroneal nerve. Both groups used the same shoes during the tests. Spatiotemporal variables assessed were velocity (m/s), cadence (steps per minute), step length (m) and percentage of stance time. All variables except for the percentage of stance time showed significant differences between groups and with and without AFO. In ankle joint kinematics, the initial contact was different between groups (p=0,026), range of motion (ROM) in stance was significant difference with and without AFO (p=0,01), between groups (p=0,02) and in the interaction between groups and with and without AFO (p=0,008), ROM in balance was different between with and without AFO (p=0,002) and in the interaction between groups and with and without AFO (p=0,007). The knee kinematics displayed significant changes between with and without AFO in initial contact (p=0,002), ROM in stance (p=0,0001) and flexion at toe-off (p=0,018), between groups difference was noted in flexion at toe-off (p<0,0001) and maximum flexion in balance (p<0,0001). The hip significant differences were only observed between groups in initial contact (p<0,0001), maximum extension in balance (p=0,002), extension at toe-off (p=0,005) and in maximum flexion in balance (p=0,001). Ankle joint kinetic variables assessed were the moment at load response and maximum plantar flexor moment, both displayed significant changes between groups (p=0,012 and p=0,014), only the moment at load response was different between with and without AFO (p=0,015). Knee and hip were assessed maximum flexor and extensor moments. Only the maximum knee extensor moment was significant different between groups (p=0,0002). Hip flexor moment values were significant between groups (p<0,0001). The spatiotemporal results suggest that the gait with AFO is more effective for complete paraplegics individuals. Furthermore, the AFO allowed a greater knee protection to these individuals and also yielded a higher mechanical loading on the hip, which can prevent the loss bone mass / Mestrado / Fisiopatologia Cirúrgica / Mestre em Ciências
13

Análise biomecânica da utilização de palmilha em cunha medial associada à estabilizador de tornozelo / Biomechanical evaluation of medial-wedge insoles and ankle support in patients with valgus knee osteoarthritis

Priscilla Teixeira Rodrigues 22 June 2011 (has links)
INTRODUÇÃO: Estudo prévio do nosso grupo demonstrou que uso de palmilha em cunha medial associada ao estabilizador de tornozelo produz uma melhora clínica na osteoartrite do joelho valgo. No entanto, não existem dados na literatura sobre os efeitos biomecânicos destas órteses. OBJETIVO: Avaliação biomecânica dos pés, de maneira estática e dinâmica na osteoartrite do joelho valgo com a utilização de palmilha em cunha medial associada ao estabilizador de tornozelo. MÉTODO: Um total de 42 pés de 21 mulheres com osteoartrite de joelho bilateral (critérios ACR) e deformidade em valgo > 8 graus, foram avaliadas quanto a dados clínicos e biometria. As pacientes foram avaliadas em esteira ergométrica elétrica com: 1. calçado padrão sem a palmilha (controle), 2. palmilha em cunha medial (com 8 mm de elevação medial no retropé) e 3. com essas palmilhas e estabilizador de tornozelo em neoprene. O sistema FSCAN® versão 3.816, com palmilhas flexíveis e 960 sensores de carga na superfície foi utilizado para obter a força plantar vertical. RESULTADOS: Houve redução no pico de pressão plantar estático (PP) com a utilização da palmilha em cunha (P = 0,001) e com a palmilha e estabilizador (P < 0,001) vs. controle em ambos os lados. Além disso, o uso da palmilha associada ao estabilizador de tornozelo resultou em uma redução mais efetiva neste parâmetro em comparação ao uso somente da palmilha (P = 0,027). A avaliação dinâmica deste parâmetro revelou resultado similar no lado direito, com uma redução mais significativa com o uso da palmilha (P < 0,001) e com palmilha e estabilizador de tornozelo (P < 0,001) em relação ao controle. Não foi observada diferença no lado esquerdo (osteoartrite mais grave). A força vertical máxima estática (FVM) também demonstrou diminuição em ambos os lados com o uso da palmilha (P = 0,001) e palmilha associada ao estabilizador de tornozelo (P < 0,001) em relação ao controle. Além disso, o uso da palmilha associada ao estabilizador de tornozelo resultou em uma redução mais efetiva da força vertical máxima estática em comparação ao uso somente da palmilha (P = 0,041). Da mesma forma, na condição dinâmica, esse parâmetro foi significativamente reduzido com o uso da palmilha associada ao estabilizador de tornozelo em comparação à condição controle (P < 0,001). Também houve redução na FVM entre o uso de palmilha com e sem estabilizador (P = 0,003). A avaliação qualitativa revelou que a órtese altera significativamente a trajetória do vetor de força (P < 0,001). CONCLUSÃO: O uso da palmilha em cunha medial associada ao estabilizador de tornozelo promoveu uma redução no pico de pressão plantar e na força vertical máxima em condições estática e dinâmica, subjacente à melhora clínica na osteoartrite do joelho valgo / INTRODUCTION: We have previously demonstrated a significant clinical improvement in valgus knee osteoarthritis with the use of medial-wedge insole associated with ankle support. There is, however, no data regarding the foot plantar forces underlying this beneficial effect. Objective: Static and dynamic feet plantar biomechanical evaluation of medial-wedge insole associated with ankle support in valgus knee osteoarthritis. METHOD: A total of 42 feet of 21 women with bilateral knee osteoarthritis (ACR criteria), with valgus deformity were evaluated regarding clinical and biometric data. Patients were assessed with: 1. standard shoes without the insoles (control); 2. medial-wedge insole; 3. insoles/neoprene ankle support. The system FSCAN® 3816 version, with flexible soles and 960 load sensors on the surface was used to obtain the foot plantar vertical forces. RESULTS: A decreased peak plantar pressure was observed with insoles (P = 0,001) and insoles/ankle support (P < 0,001) vs. control while standing motionless in both sides. In addition, insoles/ankle support resulted in a more effective reduction in this parameter than solely insoles (P = 0,027). The dynamic evaluation of this parameter revealed a similar finding on the right side with a more significant reduction with use of insoles (P < 0,001) and with insoles/ankle support (P < 0,001) compared to controls. No difference was observed on the left side (more severe OA). The static maximum vertical force was also decreased in both sides with insoles (P = 0,001) and insoles/ankle support (P < 0,001) compared to control. In addition, the later condition provided a more significant reduction in the static maximum vertical force than solely insoles (P = 0,041). Likewise, in the dynamic condition this parameter was significantly reduced with insoles/ankle support compared with control condition (P < 0,001) and solely insoles (P = 0,003). The qualitative evaluation revealed that orthoses significantly changed the center of force shift (P < 0,001). CONCLUSION: We have identified that a reduction in the feet plantar peak and maximum vertical force in valgus knee osteoarthritis in static and dynamic conditions underlies the clinical improvement of medial-wedge insole associated with ankle support
14

Gait changes associated with the reduced push-off from solid ankle foot orthoses

Tanor, Joshua 28 September 2021 (has links)
Ankle foot orthoses (AFOs) are used to improve walking in some lower extremity conditions but AFOs restrict ankle motion resulting in a trade-off in ankle and hip mechanics. While the use of AFOs have been well documented, there still remain gaps in the literature. The first study compared the differences in sagittal plane ankle and hip kinematics and kinetics across three conditions at two speeds in healthy individuals while the second study compared frontal plane kinetics at the hip and knee and vertical ground reaction forces between two conditions at two speeds in healthy individuals. This was studied by collecting and analyzing three-dimensional joint kinematics and ground reaction forces from twelve healthy adults. Participants walked in three conditions (shod; i.e. athletic shoes only and two reduced push-off conditions using solid ankle foot orthoses (SAFOs); i.e. unilateral brace and bilateral brace conditions) and at two speeds (1.25m/s and 1.5m/s). In the first study, generalized linear models with general estimating equations were used to compare ankle and hip angles, moments and power for the braced and unbraced sides separately in all three conditions. In the second study, frontal plane kinetics and vertical ground reaction forces in the unbraced limb in the unilateral brace condition were compared to the same side during shod walking using paired sample t-tests. From our first study we found that the reduced push-off from the use of SAFOs results in decreased peak plantarflexion angles and power generation at the ankle and increased peak flexion angles, and first and second peak power generation at the hip in the braced limbs in both unilateral (p≤0.05) and bilateral (p≤0.05) brace conditions at both speeds. On the unbraced side in the unilateral brace condition, there were decreased peak power generation at the ankle at 1.25m/s and increased peak extension moments, first and second peak power generation at the hip compared to the shod condition (p<0.05) at both speeds. In the comparison between the unilateral and bilateral brace conditions, the changes in ankle and hip mechanics were similar to the changes between the shod condition and the bilateral brace condition on the unbraced side; in addition, participants also had higher peak extension moments in the unilateral brace condition compared to the bilateral brace condition (p<0.05). On the braced side, participants had lower peak plantarflexion moments at the ankle and lower peak flexion angles at the hip when walking with bilateral SAFOs, compared to walking with unilateral SAFOs (p<0.05). In the second study, we found that peak internal knee and hip abduction moments were 3% and 4% higher, respectively, in the unbraced limb in the unilateral brace condition at 1.25m/s (p≤0.041) compared to the same side in the shod condition. Peak vertical ground reaction force was 3% higher in the unbraced limb in the unilateral brace condition at both speeds (p=0.002). Findings indicate that walking with unilateral ankle foot orthoses presents an increased risk of developing secondary conditions.
15

Projeto e fabricação de componentes de órteses em materiais poliméricos reforçados / Design and fabrication of ortheses components in reinforced polymeric material

Gonçalves, Cláudio Torres 18 September 2003 (has links)
Os materiais poliméricos reforçados vêm sendo utilizados em inúmeras aplicações que requerem um alto desempenho estrutural, obtendo-se assim, ótimos índices de aceitação por parte de projetistas e engenheiros. Estes materiais, que também são conhecidos como materiais compósitos, apresentam excelentes propriedades estruturais, as quais estão relacionadas à rigidez, flexibilidade, resistência à corrosão, fadiga e associadas a um baixo peso, possibilitando assim a sua obtenção através da utilização adequada dos mesmos. Para diversas aplicações como na aviação comercial, aviação militar, indústrias navais, indústrias de geradores eólicos, bem como para a área médica, eles são considerados como excelentes substitutos dos materiais metálicos, como ocorre nos projetos de próteses e órteses biomecânicas. Neste trabalho, faz-se a aplicação de materiais poliméricos reforçados na construção de uma componente de órtese, no que se refere às metodologias de projeto e fabricação. Variáveis relacionadas às propriedades do material serão analisadas e estudadas através de ensaios experimentais e de simulações computacionais, visando o uso adequado dos materiais compósitos e o seu desempenho na aplicação de uma componente da órtese biomecânica. Fatores relacionados ao processo, ao material, e à metodologia empregada, são determinantes para a definição das propriedades do compósito. Estes, por sua vez, serão analisados e discutidos, visando uma futura aplicação em uma órtese biomecânica. / Reinforced polymeric materials have been used in applications that require high structural performance with low weight. Such materials, known as composites materials, are able to present excellent properties concerning stiffness, strength, corrosion and fatigue, associated with weight reduction that can be obtained through an adequate use its of constituents. In many applications in the medical area, such materials are considered as a substitute for conventional metallic materials, as the case of biomechanical protheses. In this work, the application of reinforced polymeric materials in prostheses is studied concerning the design and manufacturing processes. Variables related to the material properties are analysed through experimental tests and computer simulation, in order to obtain the best configuration of material properties. It is proven that the use of composite materials is an advantageous alternative to replace metallic materials in the design and manufacturing of biomechanical prostheses.
16

Modeling & Analysis of Design Parameters for Portable Hand Orthoses to Assist Upper Motor Neuron Syndrome Impairments and Prototype Design

Nycz, Christopher Julius 01 July 2018 (has links)
Wearable assistive robotics have the potential to address an unmet medical need of reducing disability in individuals with chronic hand impairments due to neurological trauma. Despite myriad prior works, few patients have seen the benefits of such devices. Following application experience with tendon-actuated soft robotic gloves and a collaborator's orthosis with novel flat-spring actuators, we identified two common assumptions regarding hand orthosis design. The first was reliance on incomplete studies of grasping forces during activities of daily living as a basis for design criteria, leading to poor optimization. The second was a neglect of increases in muscle tone following neurological trauma, rendering most devices non-applicable to a large subset of the population. To address these gaps, we measured joint torques during activities of daily living with able-bodied subjects using dexterity representative of orthosis-aided motion. Next, we measured assistive torques needed to extend the fingers of individuals with increased flexor tone following TBI. Finally, we applied this knowledge to design a cable actuated orthosis for assisting finger extension, providing a basis for future work focused on an under-represented subgroup of patients.
17

Elaboração de fichas técnicas de materiais visando o design de órteses de membros superiores e inferiores

Danckwardt, Frances January 2016 (has links)
Este trabalho tem por objetivo principal a elaboração de fichas técnicas de materiais utilizados na fabricação de órteses de membro superior e inferior. Para a escolha dos materiais a serem elencados e caracterizados, selecionou-se as instituições de apoio ao deficiente da área metropolitana de Porto Alegre, RS. As selecionadas para a pesquisa foram a Associação de Assistência à Criança com Deficiência (AACD) e Associação Canoense de Deficientes Físicos (ACADEF). A metodologia abordou a listagem e seleção, e as etapas seguintes se deram a partir da organização dos materiais em grandes grupos: materiais poliméricos, materiais metálicos, materiais naturais e fibras. Assim agrupados, seguiu-se a caracterização e a análise dos materiais por meio de microscopia eletrônica de varredura (MEV), espectroscopia por energia dispersiva (EDS), espectroscopia no infravermelho por transformada de Fourier (FT-IR), espectrometria de fluorescência de raios-X e ensaio de tração e compressão. Os resultados práticos e as pesquisas em materiais bibliográficos e bancos de dados como o Granta Design permitiram a elaboração das fichas técnicas de cada material, apresentando as características gerais, propriedades físicas, mecânicas e químicas e aplicação. Essas fichas têm finalidade multidisciplinar, buscando auxiliar profissionais que trabalham no processo de fabricação destas órteses, como fisioterapeutas, terapeutas ocupacionais, técnicos de oficina, designers e projetistas, permitindo acesso direto e praticidade na fabricação destes produtos. / The main objective of this study is to develop technical sheets of materials utilized in the manufacturing of superior and inferior limb orthoses. Institutions that support disabled persons in the metropolitan area of Porto Alegre, RS, were selectioned in order to decide which materials were to be listed and characterized. The Association of Assistance for Children with Disability (AACD) and the Canoense Association of persons with Physical Disability (ACADEF) were selected for this research. Methods included listing and selection, and the following steps were conducted through the categorization of materials into large groups: polymeric materials, metal materials, natural materials and fibers. Thus grouped, the study continued with the characterization and analysis of materials through scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS), Fourier transform infrared spectroscopy (FT-IR), X-ray fluorescence spectrometry and tension and compression testing. Practical results and research in bibliographical material and databases such as Granta Design enabled the development of technical sheets for each material, presenting general characteristics, physical, mechanical and chemical properties and application. Such sheets have multidisciplinary purposes, seeking to assist health professionals who work in the manufacturing process of these orthoses, such as physiotherapists, occupational therapists, workshop technicians, designers and drafters, allowing for direct access and convenience in the manufacturing of these products.
18

Estudo e projeto conceitual de órtese auto-articulada para correção de deformidade em desvio ulnar dos dedos para portadores de artrite rematóide / Study and conceptual project of self-articulation orthosis to correct deformities in ulnar deviation of fingers for patients with rheumathoid arthrits

Goia, Daniela Nakandakari 08 October 2012 (has links)
Artrite reumatóide (AR) é uma doença crônica e multisistêmica, que afeta o indivíduo como um todo. De etiologia desconhecida, possui como característica uma inflamação sinovial, efeitos periarticulares, simétricas e cumulativas. Os principais sinais e sintomas apresentados na fase aguda são as dores nas articulações, edemas e rigidez matinal. E em 75% dos casos acometem membro superiores, com um grande impacto nas habilidades funcionais. Nas mãos, as deformidades podem atingir todas as articulações causando subluxações e deformidades em metacarpofalangenas (MF), interfalangeanas (IF) e punhos. Quando há a destruição dos ligamentos e cartilagens do punho as forças musculares e fatores anatômicos causam o colapso do punho em desvio radial e as articulações MF, como consequência a essas forças anatômicas, também entram em colapso e favorecem o desvio ulnar dessas articulações. Há diferentes recursos utilizados no tratamento desta patologia, sendo um deles o uso de órtese. Assim, este estudo tem por objetivo projetar e desenvolver uma órtese, articulada e original, com função de corrigir a deformidade em desvio ulnar dos dedos e favorecer a funcionalidade. Para tanto os procedimentos metodológicos foram divididos em: Reconhecimento de Necessidades; Especificação e Conceito. Após levantamento Bibliográfico, estudo antropométrico chegou-se ao esboço e ao conceito do projeto. Como resultado obteve-se o primeiro protótipo em material disponível e utilizando o programa CAD solid edge Insight foi proposto um protótipo digitalizado da órtese, definindo as propostas e requisitos necessários para o desenvolvimento da órtese. Como resultados obteve-se dois desenhos digitalizados do protótipo e quatro protótipos em materiais diferentes entre si, compostos por 9 peças (2 hastes laterais, 1 bloqueio ulnar, 3 pulseiras e 3 anéis), que montadas mostram uma órtese articulada. Observou-se que houve bloqueio do desvio ulnar mesmo em pacientes com deformidades mais graves dos dedos. A mesma permitia a flexão e extensão de MFs e punho. Houveram ajustes nos desenhos com o decorrer do estudo, após realização dos testes de bancada. Verificou-se que a órtese poderá ser utilizada bilateralmente, com uso dorsal da haste redonda em mão direita e uso ventral em mão esquerda. A órtese permite a função da mão e possui fácil colocação e manuseio. / Rheumatoid arthritis (RA) is a chronic, multisystem, which affects the individual as a whole. Of unknown etiology, is characterized as a synovial inflammation, periarticular effects, and cumulative symmetrical. The main signs and symptoms in the acute phase are joint pain, swelling and stiffness. And 75% of cases involve upper limb, with a great impact on functional abilities. Deformities in the hands can reach all the joints causing deformities and subluxations metacarpophalangeal (MF), interphalangeal (IF) and wrists. When there is destruction of cartilage and ligaments of the wrist muscle forces and anatomical factors cause the collapse of the wrist in radial deviation and MP joints, the effect of these anatomical forces also favor collapse and ulnar deviation of these joints. There are different resources used in the treatment of this pathology, one being the use of bracing. Thus, this study aims to design and develop a bracing, articulate and original, with the function to correct the deformity in ulnar deviation of fingers and promote functionality. For both methodological procedures were divided into: Recognition of Needs; Specification and Concept. After Bibliographic survey, anthropometric study came to the sketch and the concept of the project. As a result we obtained the first prototype in material available and using the CAD program Solid Edge Insight has been proposed a prototype scanned of the orthosis, setting out proposals and requirements for the development of bracing. The results we obtained two scanned drawings of the prototype and four prototypes in different materials, composed of nine parts (two lateral branches, an ulnar block, three bracelets and three rings), which show a stent mounted articulated. It was observed that the blockade of Ulnar deviation of fingers and allow flexion and extension and the MF\'s wrist. There were adjustments to the drawings in the course of the study, after completion of bench testing. We also found that the orthosis can be used bilaterally, using dorsal round rod in his right hand and left hand use ventral. The stent allows the function of the hand and has easy handling and placement.
19

Projeto e fabricação de componentes de órteses em materiais poliméricos reforçados / Design and fabrication of ortheses components in reinforced polymeric material

Cláudio Torres Gonçalves 18 September 2003 (has links)
Os materiais poliméricos reforçados vêm sendo utilizados em inúmeras aplicações que requerem um alto desempenho estrutural, obtendo-se assim, ótimos índices de aceitação por parte de projetistas e engenheiros. Estes materiais, que também são conhecidos como materiais compósitos, apresentam excelentes propriedades estruturais, as quais estão relacionadas à rigidez, flexibilidade, resistência à corrosão, fadiga e associadas a um baixo peso, possibilitando assim a sua obtenção através da utilização adequada dos mesmos. Para diversas aplicações como na aviação comercial, aviação militar, indústrias navais, indústrias de geradores eólicos, bem como para a área médica, eles são considerados como excelentes substitutos dos materiais metálicos, como ocorre nos projetos de próteses e órteses biomecânicas. Neste trabalho, faz-se a aplicação de materiais poliméricos reforçados na construção de uma componente de órtese, no que se refere às metodologias de projeto e fabricação. Variáveis relacionadas às propriedades do material serão analisadas e estudadas através de ensaios experimentais e de simulações computacionais, visando o uso adequado dos materiais compósitos e o seu desempenho na aplicação de uma componente da órtese biomecânica. Fatores relacionados ao processo, ao material, e à metodologia empregada, são determinantes para a definição das propriedades do compósito. Estes, por sua vez, serão analisados e discutidos, visando uma futura aplicação em uma órtese biomecânica. / Reinforced polymeric materials have been used in applications that require high structural performance with low weight. Such materials, known as composites materials, are able to present excellent properties concerning stiffness, strength, corrosion and fatigue, associated with weight reduction that can be obtained through an adequate use its of constituents. In many applications in the medical area, such materials are considered as a substitute for conventional metallic materials, as the case of biomechanical protheses. In this work, the application of reinforced polymeric materials in prostheses is studied concerning the design and manufacturing processes. Variables related to the material properties are analysed through experimental tests and computer simulation, in order to obtain the best configuration of material properties. It is proven that the use of composite materials is an advantageous alternative to replace metallic materials in the design and manufacturing of biomechanical prostheses.
20

Ganganalytische Bewertung der Eigenschaften von Orthesen fuer Kinder mit Spina bifida

St. Louis, Missouri / USA 02 October 2001 (has links) (PDF)
No description available.

Page generated in 0.0525 seconds