• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 27
  • 27
  • 6
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Diffusive Acoustic Confocal Imaging System (DACI): a novel method for prostate cancer diagnosis

Yin, Wen 21 December 2017 (has links)
This thesis is part of the project undertaken to develop a diffusive acoustic confocal imaging system (DACI) that aims to differentiate between healthy and the diseased tissues in the prostate. Speed of sound is chosen as the tool to quantify the alterations in the tissues’ mechanical properties at different pathological states. The current work presents a scanning configuration that features three components: an acoustic emitter, a focusing mirror and a point receiver. The focusing mirror brings the collimated acoustic beam from the emitter into a focused probe position, which needs to be located within the bladder or at the near surface of the prostate. This position is introduced as the virtual source, where the acoustic intensity diffusively scatters into all directions and propagates through the specimen. The system design was simulated using ZEMAX and COMSOL to validate the concept of the virtual source. Lesions in a phantom prostate were found in the simulated amplitude and phase images. The speed of sound variation was estimated from the 1D unwrapped phase distribution indicating where the phase discontinuities existed. The measurements were conducted in a water aquarium using the tissue-mimicking prostate phantom. Two-dimensional projected images of the amplitude and the phase distributions of the investigating acoustic beam were measured. A USRP device was set up as the signal generation and acquisition device for the experiment. Two different signal extractions methods were developed to extract the amplitude and the phase information. The experimental results were found to generally agree with the simulation results. The proof-of-concept design was successful in measuring both the phase and the amplitude information of the acoustic signal passing through the prostate phantom. In future, the 2D/3D speed of sound variation needs to be estimated by an appropriate image reconstruction method. / Graduate / 2018-12-06
22

Contribution à la caractérisation des impulsions ultra-courtes à l’aide de sources laser rapidement accordables / Contribution to the characterization of ultrashort pulses using high-speed optical swept sources

Korti, Mokhtar 18 November 2018 (has links)
Les sources laser accordables se distinguent par leur capacité à changer leur longueur d’onde d’émission de façon continue dans le temps. Elles sont utilisées dans de nombreuses applications comme les télécommunications, la spectroscopie et la tomographie optique cohérente. Elles sont caractérisées principalement par une faible largeur de raie instantanée, une grande fréquence de balayage et une large plage d’accord. Les avantages des sources accordables ouvrent la voie vers d’autres types d’applications comme la caractérisation des impulsions ultra-courtes par exemple. Généralement, ces impulsions sont caractérisées via des méthodes non linéaires, lentes et trop compliquées à mettre en place. Nous avons donc proposé une nouvelle approche basée sur les sources accordables pour la caractérisation des impulsions ultra-courtes. En utilisant un laser à semi-conducteur accordable linéairement, type SG-DBR (Sampled-Grating Distributed Bragg Reflector), nous pouvons balayer en une seule mesure tout le spectre optique des impulsions sous test. Le signal de battement entre la source accordable et le laser pulsé permet de mesurer l’amplitude et la phase spectrales des différents modes ce qui nous donne accès à la forme temporelle de l’impulsion. L’avantage de notre approche est que tout le processus de caractérisation se fait en une seule mesure très rapide. En effet, la grande fréquence de balayage du laser accordable permet d’avoir des temps de mesure très faibles (< 10 μs), ce qui offre la possibilité d’avoir des mesures en temps réel. De plus, grâce à la large plage d’accord, cette technique est complétement indépendante de l’impulsion sous test, elle ne nécessite aucune connaissance au préalable des différentes propriétés de cette dernière telles que la fréquence de répétition, le nombre de modes ou la fréquence de chaque mode / Optical swept sources are distinguished by the ability to change their output wavelength in a continuous manner over time. They are used in many applications such as telecommunications, spectroscopy and optical coherence tomography. They are mainly characterized by a narrow instantaneous linewidth, a high sweep rate and a wide tuning range. The advantages of swept sources open the way to other types of applications such as the characterization of ultrashort pulses for example. Generally, these pulses are characterized using nonlinear methods which are slow and too complicated. We have proposed a novel approach based on swept sources for the characterization of ultrashort pulses. By using a linearly wavelength-swept semiconductor laser like SG-DBR (Sampled-Grating Distributed Bragg Reflector), we can scan the entire optical spectrum of the pulses under test in a single measurement. The beat signal between the swept source and the pulsed laser is then used to measure the spectral amplitude and phase of all modes which gives access to the temporal shape of the pulse. The main advantage of our approach is that the entire characterization process is done in a single fast measurement. Indeed, the high sweep rate of the swept source offers the possibility of having real time measurements. In addition, thanks to the wide tuning range, this technique is completely independent of the pulse under test, it requires no prior knowledge of the various properties of the pulse such as the repetition frequency, the number of modes or the frequency of each mode
23

Correction active des discontinuités pupillaires des télescopes à miroir segmenté pour l’imagerie haut contraste et la haute résolution angulaire / Active correction of pupil discontinuities on segmented telescopes for high contrast imaging and high angular resolution

Janin-Potiron, Pierre 19 October 2017 (has links)
La recherche de signes de vie extraterrestre par l'observation et la caractérisation d'exoplanètes est, entre autres, l'un des enjeux majeurs de l'astrophysique moderne. Cette quête se traduit de manière instrumentale par le développement de télescopes fournissant des résolutions angulaires supérieures à celles obtenues à l'heure actuelle. C'est pourquoi les projets de futurs très grands télescopes font usage de miroirs primaires dépassant les 30 mètres de diamètre. Leur conception est alors inévitablement basée, pour des raisons techniques et technologiques, sur une géométrie segmentée. De ce fait, la segmentation du miroir primaire implique une complexification des structures pupillaires du télescope. Dans le but d'atteindre les niveaux de qualité optique nécessaires aux applications scientifiques visées, la prise en compte et la correction des effets introduits par un mauvais alignement des segments est de prime importance puisque la résolution angulaire d'un télescope non cophasé serait équivalente à celle obtenue avec un segment individuel. Dans ce contexte, je développe dans cette thèse deux analyseurs de cophasage permettant de mesurer et de corriger les aberrations de piston, tip et tilt présentes sur une pupille segmentée. Le premier, nommé Self-Coherent Camera - Phasing Sensor (SCC-PS), est basé sur une analyse du signal en plan focal. Le second, nommé ZELDA - Phasing Sensor (ZELDA-PS), repose quant à lui sur une analyse du signal en plan pupille. Sont présentés dans ce manuscrit les résultats obtenus à l'aide de simulations numériques ainsi que ceux issus de l'implémentation de la SCC-PS sur un banc d'optique d'essai. / Searching for extraterrestrial life through the observation and characterization of exoplanets is, amongst others, one of the major goal of the modern astrophysics. This quest translate from an instrumental point of view to the development of telescope capable of reaching higher angular resolution that what is actually ongoing. That is why the future projects of extremely large telescopes are using primary mirrors exceeding the 30 meters in diameter. Their conception is consequently based, for technical and technological reasons, on a segmented geometry. The segmentation of the primary mirror therefore implies a growing complexity of the structure of its pupil. In order to reach the optical quality required by the sciences cases of interest, taking into account and correct for the effects introduced by a poor alignment of the segments is mandatory, as the angular resolution of a non-cophased telescope is equivalent to the one obtained with a single segment. In this context, I develop in this manuscript two cophasing sensors allowing to measure and correct for the aberrations of piston, tip and tilt present on a segmented pupil. The first one, the Self-Coherent Camera - Phasing Sensor (SCC-PS), is based on a focal plane analysis of the signal. The second one, the ZELDA - Phasing Sensor (ZELDA-PS), is based on a pupil plane analysis of the signal. The results obtained by means of numerical simulations and the first results coming from the implementation of the SCC-PS on an optical bench are presented in this manuscript.
24

Ultra precision metrology : the key for mask lithography and manufacturing of high definition displays

Ekberg, Peter January 2011 (has links)
Metrology is the science of measurement. It is also a prerequisite for maintaining a high quality in all manufacturing processes. In this thesis we will present the demands and solutions for ultra-precision metrology in the manufacturing of lithography masks for the TV-display industry. The extreme challenge that needs to be overcome is a measurement uncertainty of 10 nm on an absolute scale of more that 2 meters in X and Y. Materials such as metal, ceramic composites, quartz or glass are highly affected by the surrounding temperature when tolerances are specified at nanometer levels. Also the fact that the refractive index of air in the interferometers measuring absolute distances is affected by temperature, pressure, humidity and CO2 contents makes the reference measurements really challenging. This goes hand in hand with the ability of how to design a mask writer, a pattern generator with a performance good enough for writing masks for the display industry with sub-micron accuracy over areas of square meters.  As in many other areas in the industry high quality metrology is the key for success in developing high accuracy production tools. The aim of this thesis is therefore to discuss the metrology requirements of mask making for display screens. Defects that cause stripes in the image of a display, the so called “Mura” effect, are extremely difficult to measure as they are caused by spatially systematic errors in the mask writing process in the range of 10-20 nm. These errors may spatially extend in several hundreds of mm and are superposed by random noise with significantly higher amplitude compared to the 10-20 nm.  A novel method for measuring chromium patterns on glass substrates will also be presented in this thesis. This method will be compared to methods based on CCD and CMOS images. Different methods have been implementedin the Micronic MMS1500 large area measuring machine, which is the metrology tool used by the mask industry, for verifying the masks made by the Micronic mask writers. Using alternative methods in the same system has been very efficient for handling different measurement situations. Some of  the discussed methods are also used by the writers for calibration purposes. / QC 20110517
25

3D shape measurements with a single interferometric sensor for insitu lathe monitoring

Kuschmierz, R., Huang, Y., Czarske, J., Metschke, S., Löffler, F., Fischer, A. 29 August 2019 (has links)
Temperature drifts, tool deterioration, unknown vibrations as well as spindle play are major effects which decrease the achievable precision of computerized numerically controlled (CNC) lathes and lead to shape deviations between the processed work pieces. Since currently no measurement system exist for fast, precise and insitu 3d shape monitoring with keyhole access, much effort has to be made to simulate and compensate these effects. Therefore we introduce an optical interferometric sensor for absolute 3d shape measurements, which was integrated into a working lathe. According to the spindle rotational speed, a measurement rate of 2,500 Hz was achieved. In-situ absolute shape, surface profile and vibration measurements are presented. While thermal drifts of the sensor led to errors of several µm for the absolute shape, reference measurements with a coordinate machine show, that the surface profile could be measured with an uncertainty below one micron. Additionally, the spindle play of 0.8 µm was measured with the sensor.
26

Development of a data acquisition architecture with distributed synchronization for a Positron Emission Tomography system with integrated front-end

Aliaga Varea, Ramón José 02 May 2016 (has links)
[EN] Positron Emission Tomography (PET) is a non-invasive nuclear medical imaging modality that makes it possible to observe the distribution of metabolic substances within a patient's body after marking them with radioactive isotopes and arranging an annular scanner around him in order to detect their decays. The main applications of this technique are the detection and tracing of tumors in cancer patients and metabolic studies with small animals. The Electronic Design for Nuclear Applications (EDNA) research group within the Instituto de Instrumentación para Imagen Molecular (I3M) has been involved in the study of high performance PET systems and maintains a small experimental setup with two detector modules. This thesis is framed within the necessity of developing a new data acquisition system (DAQ) for the aforementioned setup that corrects the drawbacks of the existing one. The main objective is to define a DAQ architecture that is completely scalable, modular, and guarantees the mobility and the possibility of reusing its components, so that it admits any extension of modification of the setup and it is possible to export it directly to the configurations used by other groups or experiments. At the same time, this architecture should be compatible with the best possible resolutions attainable at the present instead of imposing artificial limits on system performance. In particular, the new DAQ system should outperform the previous one. As a first step, a general study of DAQ arquitectures is carried out in the context of experimental setups for PET and other high energy physics applications. On one hand, the conclusion is reached that the desired specifications require early digitization of detector signals, exclusively digital communication between modules, and the absence of a centralized trigger. On the other hand, the necessity of a very precise distributed synchronization scheme between modules becomes apparent, with errors in the order of 100 ps, and operating directly over the data links. A study of the existing methods reveals their severe limitations in terms of achievable precision. A theoretical analysis of the situation is carried out with the goal of overcoming them, and a new synchronization algorithm is proposed that is able to reach the desired resolution while getting rid of the restrictions on clock alignment that are imposed by virtually all usual schemes. Since the measurement of clock phase difference plays a crucial role in the proposed algorithm, extensions to the existing methods are defined and analyzed that improve them significantly. The proposed scheme for synchronism is validated using commercial evaluation boards. Taking the proposed synchronization method as a starting point, a DAQ architecture for PET is defined that is composed of two types of module (acquisition and concentration) whose replication makes it possible to arrange a hierarchic system of arbitrary size, and circuit boards are designed and commissioned that implement a realization of the architecture for the particular case of two detectors. This DAQ is finally installed at the experimental setup, where their synchronization properties and resolution as a PET system are characterized and its performance is verified to have improved with respect to the previous system. / [ES] La Tomografía por Emisión de Positrones (PET) es una modalidad de imagen médica nuclear no invasiva que permite observar la distribución de sustancias metabólicas en el interior del cuerpo de un paciente tras marcarlas con isótopos radioactivos y disponer después un escáner anular a su alrededor para detectar su desintegración. Las principales aplicaciones de esta técnica son la detección y seguimiento de tumores en pacientes con cáncer y los estudios metabólicos en animales pequeños. El grupo de investigación Electronic Design for Nuclear Applications (EDNA) del Instituto de Instrumentación para Imagen Molecular (I3M) ha estado involucrado en el estudio de sistemas PET de alto rendimiento y mantiene un pequeño setup experimental con dos módulos detectores. La presente tesis se enmarca dentro de la necesidad de desarrollar un nuevo sistema de adquisición de datos (DAQ) para dicho setup que corrija los inconvenientes del ya existente. En particular, el objetivo es definir una arquitectura de DAQ que sea totalmente escalable, modular, y que asegure la movilidad y la posibilidad de reutilización de sus componentes, de manera que admita cualquier ampliación o alteración del setup y pueda exportarse directamente a los de otros grupos o experimentos. Al mismo tiempo, se desea que dicha arquitectura no limite artificialmente el rendimiento del sistema sino que sea compatible con las mejores resoluciones disponibles en la actualidad, y en particular que sus prestaciones superen a las del DAQ instalado previamente. En primer lugar, se lleva a cabo un estudio general de las arquitecturas de DAQ para setups experimentales para PET y otras aplicaciones de física de altas energías. Por un lado, se determina que las características deseadas implican la digitalización temprana de las señales del detector, la comunicación exclusivamente digital entre módulos, y la ausencia de trigger centralizado. Por otro lado, se hace patente la necesidad de un esquema de sincronización distribuida muy preciso entre módulos, con errores del orden de 100 ps, que opere directamente sobre los enlaces de datos. Un estudio de los métodos ya existentes revela sus graves limitaciones a la hora de alcanzar esas precisiones. Con el fin de paliarlos, se lleva a cabo un análisis teórico de la situación y se propone un nuevo algoritmo de sincronización que es capaz de alcanzar la resolución deseada y elimina las restricciones de alineamiento de reloj impuestas por casi todos los esquemas usuales. Dado que la medida de desfase entre relojes juega un papel crucial en el algoritmo propuesto, se definen y analizan extensiones a los métodos ya existentes que suponen una mejora sustancial. El esquema de sincronismo propuesto se valida utilizando placas de evaluación comerciales. Partiendo del método de sincronismo propuesto, se define una arquitectura de DAQ para PET compuesta de dos tipos de módulos (adquisición y concentración) cuya replicación permite construir un sistema jerárquico de tamaño arbitrario, y se diseñan e implementan placas de circuito basadas en dicha arquitectura para el caso particular de dos detectores. El DAQ así construído se instala finalmente en el setup experimental, donde se caracterizan tanto sus propiedades de sincronización como su resolución como sistema PET y se comprueba que sus prestaciones son superiores a las del sistema previo. / [CA] La Tomografia per Emissió de Positrons (PET) és una modalitat d'imatge mèdica nuclear no invasiva que permet observar la distribució de substàncies metabòliques a l'interior del cos d'un pacient després d'haver-les marcat amb isòtops radioactius disposant un escàner anular al seu voltant per a detectar la seua desintegració. Aquesta tècnica troba les seues principals aplicacions a la detecció i seguiment de tumors a pacients amb càncer i als estudis metabòlics en animals petits. El grup d'investigació Electronic Design for Nuclear Applications (EDNA) de l'Instituto de Instrumentación para Imagen Molecular (I3M) ha estat involucrat en l'estudi de sistemes PET d'alt rendiment i manté un petit setup experimental amb dos mòduls detectors. Aquesta tesi neix de la necessitat de desenvolupar un nou sistema d'adquisició de dades (DAQ) per al setup esmentat que corregisca els inconvenients de l'anterior. En particular, l'objectiu és definir una arquitectura de DAQ que sigui totalment escalable, modular, i que asseguri la mobilitat i la possibilitat de reutilització dels seus components, de tal manera que admeta qualsevol ampliació o alteració del setup i pugui exportar-se directament a aquells d'altres grups o experiments. Al mateix temps, es desitja que aquesta arquitectura no introduisca límits artificials al rendiment del sistema sinó que sigui compatible amb les millors resolucions disponibles a l'actualitat, i en particular que les seues prestacions siguin superiors a les del DAQ instal.lat amb anterioritat. En primer lloc, es porta a terme un estudi general de les arquitectures de DAQ per a setups experimentals per a PET i altres aplicacions de física d'altes energies. Per una banda, s'arriba a la conclusió que les característiques desitjades impliquen la digitalització dels senyals del detector el més aviat possible, la comunicació exclusivament digital entre mòduls, i l'absència de trigger centralitzat. D'altra banda, es fa palesa la necessitat d'un mecanisme de sincronització distribuïda molt precís entre mòduls, amb errors de l'ordre de 100 ps, que treballi directament sobre els enllaços de dades. Un estudi dels mètodes ja existents revela les seues greus limitacions a l'hora d'assolir aquest nivell de precisió. Amb l'objectiu de pal.liar-les, es duu a terme una anàlisi teòrica de la situació i es proposa un nou algoritme de sincronització que és capaç d'obtindre la resolució desitjada i es desfà de les restriccions d'alineament de rellotges imposades per gairebé tots els esquemes usuals. Atès que la mesura del desfasament entre rellotges juga un paper cabdal a l'algoritme proposat, es defineixen i analitzen extensions als mètodes ja existents que suposen una millora substancial. L'esquema de sincronisme proposat es valida mitjançant plaques d'avaluació comercials. Prenent el mètode proposat com a punt de partida, es defineix una arquitectura de DAQ per a PET composta de dos tipus de mòduls (d'adquisició i de concentració) tals que la replicació d'aquests elements permet construir un sistema jeràrquic de mida arbitrària, i es dissenyen i implementen plaques de circuit basades en aquesta arquitectura per al cas particular de dos detectors. L'electrònica desenvolupada s'instal.la finalment al setup experimental, on es caracteritzen tant les seues propietats de sincronització com la seua resolució com a sistema PET i es comprova que les seues prestacions són superiors a les del sistema previ. / Aliaga Varea, RJ. (2016). Development of a data acquisition architecture with distributed synchronization for a Positron Emission Tomography system with integrated front-end [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/63271 / Premios Extraordinarios de tesis doctorales
27

Etude ultra-sensible en phase de nano-structures par interferométrie optique à balayage en champ proche / A study on ultra-sensitive phase in nano-structures by near-field scanning optical interferometry

Mok, Jinmyoung 26 March 2015 (has links)
La construction d’un NSOM, dans ce manuscrit de thèse, est décrite en détail. Lacombinaison du système NSOM construit avec un interféromètre est proposée afin d’accéderà des mesures de phase, à la fois de ultra-haute sensibilité mais également de très granderésolution spatiale. Le nom de l’instrument développé est un interferomètre optique àbalayage en champ proche (NSOI, pour l’acronyme en anglais). Le principe est basé surl’utilisation d’un diapason accordable en cristal de quartz, sur lequel se trouve une pointe,afin de sonder le matériau étudié. La mesure de la force de cisaillement de la pointe sondeau voisinage de la surface permet d’assurer la régulation et la stabilité de la distance depositionnement de la pointe par rapport à la surface considérée. Le dispositif est construit encombinant différents éléments électroniques pilotés par un logiciel développé en langageLab-VIEW. Le bruit de la mesure en NSOI est supprimé par un calcul simple basé sur lathéorie de l’optique ondulatoire et des interférences associées. Le système permet deréaliser des mesures optiques en champ proche ainsi que la détermination en hauterésolution de la phase du champ optique. L’échantillon SNG01 (l’un des réseaux utilisés pourcaractériser notre microscope à balayage en champ proche), ainsi que des disques optiques(CD, DVD and disques blu-ray) ont été utilisés pour tester la faisabilité et les performancesde notre système.Dans ce manuscrit de thèse, le graphène et les monocouches de MoS2 sont étudiés. Nous montrons qu’une épaisseur à l’échelle atomique peut être résolue par notresystème NSOI, avec l’utilisation de l’algorithme de suppression du bruit de mesure. Lesjoints de grain du graphène sont observés à grande échelle, via la technique d’imagerie parcollection en champ proche et par la réalisation de cartographies de phase. En particulier,les tensions internes à une couche de graphène sont observées, uniquement dans le casd’une imagerie de phase. / In this thesis, near-field scanning optical interferometry (NSOI), which combinesNSOM with interferometer, is proposed for the phase measurement. The shear-forcedetection scheme is applied for distance regulation. The hardware of the systemis constructed by combining various electronic devices, and the operating softwareis coded by LabVIEW. Unwanted background signal is removed by simple calculationbased on interference theory. By using this, the near-field optical measurementand the ultra-sensitive phase investigation of nano-materials are performed. 2D materialssuch as graphene and monolayer MoS2 are investigated. It is shown thatatomic-scale thickness can be resolved by the NSOI. Especially, the grain boundariesof graphene and the seed of MoS2 can be found by phase detection. In addition,direct laser writing (DLW) on silver-containing glass is observed by using NSOM,and NSOI. For the first time, the writing threshold is correlatively observed in thefluorescence imaging and the near-field phase image.

Page generated in 0.0697 seconds