Spelling suggestions: "subject:"electroacoustic spectroscopy.""
21 |
Uso das técnicas de microbalança de cristal de quartzo e espectroscopia fotoacústica para estudo e monitoramento do processo de fotocura de resinas odontológicas / Use of quartz crystal microbalance and photoacoustic spectroscopy techniques to study and monitor the photocuring process of dental resinsMarcenilda Amorim Lima 20 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / As resinas fotocuradas são amplamente utilizadas em odontologia. Este processo de
cura é assistido pela luz visível que promove ligações químicas que as endurecem. Nesta
dissertação, as resinas odontológicas fotocuradas comerciais das marcas Opallis Flow A1, A2,
AO 3,5, T, Opallis DA2, Natural Flow e Ebecryl 3720-TP25 foram caracterizadas
empregando as técnicas de microbalança de cristal de quartzo (QCM) e espectroscopia
fotoacústica (PAS) à temperatura ambiente. A espectroscopia fotoacústica foi utilizada para
avaliar a região do espectro eletromagnético responsável pela fotocura das resinas
odontológicas. Desta forma, conhecendo-se o comprimento de onda da absorção da resina,
possibilitou realizar o processo de fotocura. Adicionalmente, foi possível monitorar o
processo de fotocura com a técnica de microbalança. A frequência de ressonância do cristal da
microbalança se modifica com a fotocura das resinas estudadas. Deste modo, foi possível
estimar por QCM, o tempo de cura para os comprimentos de ondas caracterizados por PAS. / Photocured resins are largely used in dentistry. The curing process is visible light
assisted provoking the chemical bonds that hardens the resin. In this dissertation, commercial
photocured dentistry resins of brands Opallis Flow A1, A2, AO 3,5, T, Opallis DA2, Natural
Flow and Ebecryl 3720-TP25 were characterized by quartz crystal microbalance (QCM) and
photoacoustic spectroscopy (PAS) at room temperature. Photoacoustic spectroscopy was used
to assess the region of the electromagnetic spectrum that is responsible for curing dental
resins. Thus, knowing the absorption wavelength of the resin allowed the photocuring
processes. Besides, the cure was monitored using microbalance technique. The ressonance
frequency of the crystal microbalance changes during the photocuring processes. In this way,
it was possible to evaluate by QCM the cure time for the wavelengths characterized by PAS.
|
22 |
Monitoramento de cura e fotocura de resinas epóxi através da espectroscopia fotoacústica / Cure and photocuring processes of epoxy resins monitored by photoacoustic spectroscopyFrancis de Souza Borges 20 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho foi proposto o monitoramento do processo de cura e fotocura de resinas epóxi através da Espectroscopia Fotoacústica. Nos experimentos, foram utilizados dois tipos de resinas epóxi: A resina Epoxtec 331, com o endurecedor DER 24, e a resina fotocurada EBECRYL 3720-TP25, com o fotoiniciador OMNIRAD 808. Foram utilizados dois modelos de células fotoacústicas: uma baseada na técnica de diferença de fase dos dois feixes (T2F); e outra convencional. São apresentadas as montagens experimentais desenvolvidas para os monitoramentos da cura e fotocura das resinas. O estudo foi realizado monitorando o sinal fotoacústico fazendo varredura em comprimentos de onda. Também foi monitorado o sinal fotoacústico em função do tempo durante as curas e fotocuras. Foi estudado o efeito de luz saturante, não modulada, nos processos de fotocura. Tanto a amplitude quanto a fase do sinal fotoacústico revelaram-se boas ferramentas para o monitoramento proposto. Apesar de muitos dos efeitos encontrados, nos estudos realizados, ainda não terem explicação, o presente trabalho mostrou a potencialidade da espectroscopia fotoacústica para esta área de pesquisa. / In this work it was proposed the monitoring of the cure and photocuring of epoxy resins by Photoacoustic Spectroscopy. In the experiments, two types of epoxy resins were used: the resin Epoxtec 331,with the hardener DER 24; and the resin EBECRYL 3720 - TP25, with the photoinitiator 808 OMNIRAD. Two models of Photoacoustic cell were used: one based on two-beam phase-lag technique (T2F); and a conventional one. The developed set-ups for monitoring of cure and photocuring of epoxy resins are presented. The study was carried out with monitoring the photoacoustic signal on the wavelengths scan. Also the photoacoustic signal as a function of time was observed during the cure and photocuring. The effect of unmodulated saturating light was studied in the processes of photocuring. Both the amplitude and the phase of the photoacoustic signal proved to be good tools for the proposed monitoring. Although many of the effects found in these studies have not yet been explained, the present study showed the potential of photoacoustic spectroscopy to this area of research.
|
23 |
Caracterizacao espectroscopica e termica de esmalte e dentina bovinos utilizando o efeito fotoacusticoSTOLF, SANDRO F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:48:08Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:31Z (GMT). No. of bitstreams: 1
09302.pdf: 3407854 bytes, checksum: 9ad0354f272b3e3c59f9432ff90a5c98 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
24 |
Propriedades luminescentes do SrGa2O4 dopado com íons de Ni2+ / Luminescent properties of SrGa2O4 doped with Ni2+ ionsJéssica Furtado Guimarães 15 March 2013 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / O objetivo deste trabalho é a síntese e investigação estrutural e óptica de amostras SrGa2O4 dopados com 1% de íons Ni2+. Estas amostras foram sintetizados por reação do estado sólido convencional, utilizando como materiais de partida de alta pureza Ga2O3, SrCO3 e NiO em quantidades estequiométricas. As amostras foram caracterizadas estruturalmente pelo método de difração de raios - X( XRD ) e as medições de difração
mostraram que as amostras têm uma única fase monoclínica. Os padrões de XRD também foram refinados pelo método de Rietveld, que permitiu a determinação dos parâmetros de
célula unitária. A Caracterização óptica das amostras puras e dopadas SrGa2O4 foram realizadas as medições a partir de fotoluminescência, de excitação e de absorção fotoacústica,
à temperatura ambiente. Os espectros de emissão mostraram três bandas de emissão localizadas em 557 nm, 661 nm e 844 nm e foram identificadas essas bandas, respectivamente, com as seguintes transições eletrônicas :1T2 (1D) → 3A2 (3F), 3T1 (3F)→ 3A2 (3F) e 1T2 (1D) → 3T2 (3F). Os espectros de excitação mostraram seis bandas de absorção
associadas às transições electrônicas do nível 3A2 (3F) para o 3T1 (3P) , T1 (3P), 1A1 (1G), 1T2 (1D), 3T1 (3F), 1E (1D) e 1T2, 1E (1G). Medidas de absorção fotoacústica também foram
realizados com o fim de verificar as transições ópticas observadas nos espectros de excitação e de identificar novas bandas de absorção óptica. Os resultados demonstraram que os íons de Ni2+ ocupam dois locais octaédricos diferentes na amostra SrGa2O4 dopado. A partir das transições ópticas observadas nos espectros de excitação e fotoacústica, determinou-se o parâmetro de cristal de campo, dq, e parâmetros Racah, B e C. A proporção Dq / B ≈ 1.2 para
ambos os locais são típicos para Ni2+ íons inseridos em redes de óxido e em coordenação octaédrica. / The aim of this work is the synthesis and structural and optical investigation of SrGa2O4 samples doped with 1% of Ni2+ ions. These samples were synthesized by conventional solid-state reaction using as starting materials high purity SrCO3, Ga2O3 and NiO in stoichiometric quantities. Samples were structurally characterized by X-ray diffraction (XRD) method and the diffraction measurements showed that the samples have a single
monoclinic phase. The XRD patterns were also refined by the Rietveld method which allowed the determination of the unit cell parameters. Optical characterization of the pure and doped
SrGa2O4 samples were performed from photoluminescence, excitation and photoacoustic absorption measurements at room temperature. Emission spectra showed three emission bands
localized at 557 nm, 661 nm and 844 nm and these bands were identified, respectively, with the following electronic transitions: 1T2 (1D) → 3A2 (3F), 3T1 (3F)→ 3A2 (3F) e 1T2 (1D) → 3T1
(3F). Excitation spectra showed six absorption bands associated to the electronic transitions from the level 3A2 (3F) to the 3T1 (3P), 1A1 (1G), 1T2 (1D), 3T1 (3F), 1E (1D) e 1T2, 1E (1G) levels. Photoacoustic absorption measurements were also carried out in order to verify the optical transitions observed in the excitation spectra and to identify new optical absorption bands. The results showed that Ni2+ ions occupy two different octahedral sites in the SrGa2O4 doped sample. From the optical transitions observed in the excitation and photoacoustic spectra, we determined the crystal-field parameter, Dq, and Racah parameters, B and C. The ratio Dq/B ≈
1.2 for both sites are typical for Ni2+ ions inserted in oxide lattices and in octahedral coordination.
|
25 |
Identificação da formação de titanato de bário a partir de mistura reacional calcinada em diferentes temperaturas via difração de raios X, espectroscopia fotoacústica e análise térmica / Identification of the formation of barium titanate produced by solid state reaction from reaction mixtures calcined at different temperature by X-ray diffraction, photoacoustic spectroscopy and thermal analysisGeysa Negreiros Carneiro 19 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Os materiais ferroelétricos têm sido utilizados em muitas áreas da tecnologia e da ciência, pois possuem um grande número de aplicações, como: sensores; transdutores; capacitores; dispositivos ópticos; dentre outras. A busca por novos materiais cerâmicos ferroelétricos tem sido grande. Um dos materiais cerâmicos ferroelétricos mais estudados é o titanato de bário (BT). São vários os métodos de produção e caracterização do titanato de bário. Neste trabalho, pós cerâmicos de titanato de bário foram obtidos por reação do estado sólido a partir de misturas reacionais calcinadas em diferentes temperaturas entre 400C e 900C. Foram três as misturas reacionais: não dopadas; dopadas com 1%; e dopadas com 5% de dióxido de cério (CeO2). A identificação da formação do BT, nos pós cerâmicos produzidos, foi feita a partir de três técnicas de caracterização: difração de raios X (DRX); espectroscopia fotoacústica (PAS); e técnicas de análise térmica. Com a técnica DRX, difratogramas mostraram que a plena formação do titanato de bário ocorreu a partir da temperatura de calcinação de 700C. Para a amostra não dopada com cério e calcinada a 800C, houve deslocamento de todos os picos de difração. Nas amostras dopadas com dióxido de cério houve deslocamento de todos os picos de difração, em relação as amostras não dopadas. Observou-se também que nas amostras dopadas com 5% de CeO2, e calcinadas a 700C e 800C, resíduos de dióxido de cério foram observados nos difratogramas. Com a técnica PAS, espectros de absorção foram obtidos. Foi possível observar uma grande diferença de absorção da amostra calcinada a 600 e 630C, indicando a formação do titanato de bário a partir da temperatura de 630C, nas amostras sem a dopagem dióxido de cério. Houve um alargamento nas bandas de absorção a partir da temperatura de 600C, quando o dióxido de cério entrou na matriz. Foi também possível determinar as energias de band-gap das amostras utilizando o método de Tauc. Com as técnicas de análise térmica, em especial através da técnica termogravimétrica (TG/DTG), foi comprovado que até 400C não havia formação de titanato de bário. Visto que nesta temperatura de calcinação houve a maior perda de massa durante a rampa de aquecimento. O início da formação do titanato de bário foi observado a partir da temperatura de calcinação de 500C, assim como nas técnicas DRX e PAS. Portanto, com os resultados apresentados, foi demonstrada a identificação da formação do titanato de bário nas misturas reacionais calcinadas, com auxílio das potencialidades das três técnicas utilizadas. / Ferroelectric materials have been used in many areas of technology and science, because they have a large number of applications, such as sensors; transducers; capacitors; optical devices; among others. The search for new ferroelectric ceramics has been great. One of the most studied ferroelectric ceramic material is barium titanate (BT). There are several methods for production and characterization of barium titanate. In this work, ceramic powders of barium titanate were obtained by solid state reaction from reaction mixtures calcined at different temperatures between 400C and 900C. Three reaction mixtures were used: undoped; doped with 1%; and 5% doped with cerium dioxide (CeO2). The identification of the formation of BT, for the ceramic powders produced, was taken from three characterization techniques: X-ray diffraction (XRD); photoacoustic spectroscopy (PAS); and thermal analysis techniques. With the technique XRD diffraction patterns showed that complete formation of the barium titanate occurred after the calcination temperature of 700C. For the sample not doped with cerium and calcined at 800C, there was displacement of all diffraction peaks. In samples doped with cerium dioxide was no displacement of all diffraction peaks, comparing to undoped samples. It was also observed that the samples doped with 5% CeO2 and calcined at 700C and 800C, cerium dioxide residues were observed in the diffraction pattern. The absorption spectra were obtained with the technique PAS. It was possible to observe a large difference in absorption spectra in the samples calcined at 600C and 630C, indicating the formation of barium titanate at temperature of 630C in the samples without doping of cerium dioxide. There was an enlargement in the absorption band above temperature of 600C when the cerium dioxide was introduced into the matrix. It was also possible to determine the band-gap energy of the samples using the method of TAUC. With thermal analysis techniques, in particular by thermogravimetric technique (TG/DTG), has been proven that up to 400C there was no formation of barium titanate. Once, in this calcination temperature there was the largest mass loss during the heating ramp. The onset of formation of barium titanate was observed from the calcination temperature of 500C, as it has been found by the XRD and PAS techniques. Therefore, with the results presented, the identification of the formation of barium titanate calcined in reaction mixtures with the aid of the potentialities of the three techniques was demonstrated.
|
26 |
Uso das técnicas de microbalança de cristal de quartzo e espectroscopia fotoacústica para estudo e monitoramento do processo de fotocura de resinas odontológicas / Use of quartz crystal microbalance and photoacoustic spectroscopy techniques to study and monitor the photocuring process of dental resinsMarcenilda Amorim Lima 20 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / As resinas fotocuradas são amplamente utilizadas em odontologia. Este processo de
cura é assistido pela luz visível que promove ligações químicas que as endurecem. Nesta
dissertação, as resinas odontológicas fotocuradas comerciais das marcas Opallis Flow A1, A2,
AO 3,5, T, Opallis DA2, Natural Flow e Ebecryl 3720-TP25 foram caracterizadas
empregando as técnicas de microbalança de cristal de quartzo (QCM) e espectroscopia
fotoacústica (PAS) à temperatura ambiente. A espectroscopia fotoacústica foi utilizada para
avaliar a região do espectro eletromagnético responsável pela fotocura das resinas
odontológicas. Desta forma, conhecendo-se o comprimento de onda da absorção da resina,
possibilitou realizar o processo de fotocura. Adicionalmente, foi possível monitorar o
processo de fotocura com a técnica de microbalança. A frequência de ressonância do cristal da
microbalança se modifica com a fotocura das resinas estudadas. Deste modo, foi possível
estimar por QCM, o tempo de cura para os comprimentos de ondas caracterizados por PAS. / Photocured resins are largely used in dentistry. The curing process is visible light
assisted provoking the chemical bonds that hardens the resin. In this dissertation, commercial
photocured dentistry resins of brands Opallis Flow A1, A2, AO 3,5, T, Opallis DA2, Natural
Flow and Ebecryl 3720-TP25 were characterized by quartz crystal microbalance (QCM) and
photoacoustic spectroscopy (PAS) at room temperature. Photoacoustic spectroscopy was used
to assess the region of the electromagnetic spectrum that is responsible for curing dental
resins. Thus, knowing the absorption wavelength of the resin allowed the photocuring
processes. Besides, the cure was monitored using microbalance technique. The ressonance
frequency of the crystal microbalance changes during the photocuring processes. In this way,
it was possible to evaluate by QCM the cure time for the wavelengths characterized by PAS.
|
27 |
Monitoramento de cura e fotocura de resinas epóxi através da espectroscopia fotoacústica / Cure and photocuring processes of epoxy resins monitored by photoacoustic spectroscopyFrancis de Souza Borges 20 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho foi proposto o monitoramento do processo de cura e fotocura de resinas epóxi através da Espectroscopia Fotoacústica. Nos experimentos, foram utilizados dois tipos de resinas epóxi: A resina Epoxtec 331, com o endurecedor DER 24, e a resina fotocurada EBECRYL 3720-TP25, com o fotoiniciador OMNIRAD 808. Foram utilizados dois modelos de células fotoacústicas: uma baseada na técnica de diferença de fase dos dois feixes (T2F); e outra convencional. São apresentadas as montagens experimentais desenvolvidas para os monitoramentos da cura e fotocura das resinas. O estudo foi realizado monitorando o sinal fotoacústico fazendo varredura em comprimentos de onda. Também foi monitorado o sinal fotoacústico em função do tempo durante as curas e fotocuras. Foi estudado o efeito de luz saturante, não modulada, nos processos de fotocura. Tanto a amplitude quanto a fase do sinal fotoacústico revelaram-se boas ferramentas para o monitoramento proposto. Apesar de muitos dos efeitos encontrados, nos estudos realizados, ainda não terem explicação, o presente trabalho mostrou a potencialidade da espectroscopia fotoacústica para esta área de pesquisa. / In this work it was proposed the monitoring of the cure and photocuring of epoxy resins by Photoacoustic Spectroscopy. In the experiments, two types of epoxy resins were used: the resin Epoxtec 331,with the hardener DER 24; and the resin EBECRYL 3720 - TP25, with the photoinitiator 808 OMNIRAD. Two models of Photoacoustic cell were used: one based on two-beam phase-lag technique (T2F); and a conventional one. The developed set-ups for monitoring of cure and photocuring of epoxy resins are presented. The study was carried out with monitoring the photoacoustic signal on the wavelengths scan. Also the photoacoustic signal as a function of time was observed during the cure and photocuring. The effect of unmodulated saturating light was studied in the processes of photocuring. Both the amplitude and the phase of the photoacoustic signal proved to be good tools for the proposed monitoring. Although many of the effects found in these studies have not yet been explained, the present study showed the potential of photoacoustic spectroscopy to this area of research.
|
28 |
Caracterizacao espectroscopica e termica de esmalte e dentina bovinos utilizando o efeito fotoacusticoSTOLF, SANDRO F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:48:08Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:31Z (GMT). No. of bitstreams: 1
09302.pdf: 3407854 bytes, checksum: 9ad0354f272b3e3c59f9432ff90a5c98 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
29 |
Bombeamento óptico de moléculas polares por laser selado de 13CO2 para geração de ondas Terahertz / Optically pumped of polar molecules for sealled-off 13CO2 laser for generation Terahertz wavesCosta, Leverson Farias Lamonier 16 August 2007 (has links)
Orientador: Daniel Pereira / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-08T18:30:13Z (GMT). No. of bitstreams: 1
Costa_LeversonFariasLamonier_D.pdf: 15914858 bytes, checksum: 1c9b9d5747ffb493f5451d81d2898051 (MD5)
Previous issue date: 2007 / Resumo: Neste trabalho realizamos três importantes etapas: 1) montar e caracterizar um laser selado de 13C02, 2) empregar o laser selado de 13C02 como fonte de bombeamento óptico para a molécula de metanol CH30H, e utilizá-lo pela primeira vez, para excitar o isótopo de metanol 13CH30H para geração de ondas na região do TeraHertz (THz) e 3) Propor "assignments" para as transições THz do CH30H e do 13CH30H. Para excitar as respectivas moléculas de metanol, um tubo comercial selado de 13C02 foi montado e caracterizado num ressonador laser Fabry-Perot. Dois cabeçotes de aluminio foram conectados por 4 barras de invar, separado em 135cm. Em um dos cabeçotes, temos uma grade de difração (150 linhas/mm) na configuração Littrow para selecionar as linhas de emissao do respectivo laser. 0 2° cabeçote suporta um espelho de saída de ZnSe (90% de refletividade com 10m de raio de curvatura) acoplado num PZT para sintonia fina da frequência do laser. No sistema de alimentação, usamos uma fonte de alta tensão comercial (25kV, 8mA) operando em regime DC. Com isso, utilizamos o respectivo laser para excitar as moléculas CH30H e 13CH30H, onde fomos pioneiro no uso do mesmo para bombeio óptico da molécula 13CH30H. Decorrente disso, obtemos os espectros de absorção em torno de cada linha de emissão do 13C02 dos respectivos metanol. Estes dados serviram de referenda para investigação sistemática de novas emissões THz, onde observamos e caracterizamos 12 novas linhas THz do CH30H e 19 do 13CH30H. Todas foram caracterizadas em relação ao seu comprimento de onda, offset, pressao de trabalho, polaridade e intensidade relativa.Utilizando os dados de linhas THz observados por nós, e os espectros de absorção a Transformada de Fourier do CH30H e do 13CH30H, um programa computacional intitulado "Ritz", identificou "assignments" para 4 transições THz do CH30H e 9 emissoes THz para 13CH30H, respectivamente / Abstract: In this work we accomplish three important tasks: to mount and to characterize a laser sealed-off 13C02 to optically pump first time methanol molecules CH30H and 13CH30H for generation of TeraHertz waves; Proposed assignments for transistions THz of the CH30H and 13CH30H. For optical pumping we use a commercial sealed-off 13C02, tube in a homemade Fabry-Perot laser resonator, mounted on two aluminum blocks connected by invar rods and separeted by 1.35m. One block holds a grating (150grooves/mm) used in Littrow configuration to select the emission line, while the second block supports a ZnSe output mirror (90% reflectivity and 10m radius of curvature) mounted on a PZT for fine frequency tuning. We use high voltage power supply (25kV, 8mA) to operate the 13C02 laser in CW regime. A cooling system maintains operation of the laser tube at -10o C. Output powers of l0 W and 1l0 MHz tuning range are typical for lines with higher optical gains. After, molecules CH30H and 13CH30H, optoacoustics spectroscopy (OA) signal, obtained around each sealed-off 13C02 laser line were the starting point to search for THz laser lines. For the more intense OA signal, a systematic investigation was performed to observe and characterize 12 new THz lines of the CH30H and 19 THz emissions of 13CH30H that they had been characterized in wavelength, offset, working pressure, relativepolarity and relative intensity. The available data has been compared a Ritz analysis of the high-resolution Fourier-Transform absorption spectrum of CH30H and 13CH30H, resulting in the assignments for 4 THz transistions of the CH30H and 9 THz emissions for 13CH30H, respectively / Doutorado / Física Atômica e Molecular / Doutor em Ciências
|
30 |
Development of Fourier transform infrared spectroscopy for drug response analysisHughes, Caryn Sian January 2011 (has links)
The feasibility of FTIR-based spectroscopy as a tool to measure cellular response to therapeutics was investigated. Fourier transform mid-infrared spectroscopy has been used in conjunction with multivariate analysis (MVA) to assess the chemistry of many clinically relevant biological materials; however, the technique has not yet found its place in a clinical setting. One issue that has held the technique back is due to the spectral distortions caused by resonant Mie scattering (RMieS), which affects the ability to confidently assign molecular assignments to the spectral signals from biomaterials. In the light of recently improved understanding of RMieS, resulting in a novel correction algorithm, the analytical robustness of corrected FTIR spectra was validated against multi-discipline methods to characterise a set of renal cell lines which were selected for their difference in morphology.After validation of the FTIR methodology by discriminating different cell lines, the second stage of analyses tested the sensitivity of FTIR technique by determining if discrete chemical differences could be highlighted within a cell population of the same origin. The renal carcinoma cell line 2245R contains a sub-population to contain a sub-population of cells displaying 'stem-cell like' properties. These stem-like cells, however, are difficult to isolate and characterise by conventional '-omic' means. Finally, cellular response to chemotherapeutics was investigated using the established renal cell lines CAKI-2 and A-498. For the model, 5-fluorouracil (5FU), an established chemotherapeutic agent with known mechanisms of action was used. Novel gold-based therapeutic compounds were also assessed in parallel to determine their efficacy against renal cell carcinoma. The novel compounds displayed initial activity, as the FTIR evidence suggested compounds were able to enter the cells in the first instance, evoking a cellular response. The long-term performance, tracked with standard proliferation assays and FTIR spectroscopy in the renal cancer cell model, however, was poor. Rather than dismissing the compounds as in-active, the compounds may simply be more effective in cancer cell types of a different nature. The FTIR-based evidence provided the means to suggest such a conclusion. Overall, the initial results suggest that the combination of FTIR and MVA, in the presence of the novel RMieS-EMSC algorithm can detect differences in cellular response to chemotherapeutics. The results were also in-line with complimentary biological-based techniques, demonstrating the powerful potential of the technique as a promising drug screening tool.
|
Page generated in 0.1191 seconds