• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 57
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 71
  • 28
  • 13
  • 12
  • 12
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Avaliação do uso da macrofibra polimérica na composição de concreto para fins estruturais / Evaluation of the use of polymeric macrofiber in the concrete composition for structural purposes

Alex Macêdo Leite 22 March 2018 (has links)
O concreto reforçado com fibras (CRF) corresponde a um material compósito formado principalmente por cimento hidráulico, agregados miúdo e graúdo, água e fibras descontínuas. A principal finalidade do reforço no concreto com fibras é o aumento da capacidade resistente pós-fissuração do compósito, que reflete no ganho de tenacidade. Tradicionalmente, as fibras de aço, por possuírem elevadas rigidez e resistência à tração, são as mais utilizadas para o reforço do concreto, enquanto que as fibras sintéticas são adotadas para controle de fissuração por retração plástica do compósito. A macrofibra polimérica se trata de uma fibra sintética estrutural que se difundiu no mercado brasileiro nos últimos anos, possuindo pouca pesquisa a respeito de seu desempenho como elemento de reforço no concreto. Diante disto, nesta pesquisa foi avaliado o uso da macrofibra polimérica na composição de concreto para fins estruturais, sendo analisado o comportamento mecânico de duas matrizes de concreto reforçado com fibras, uma convencional e a outra de alta resistência, com diferentes teores de fibra de aço e de macrofibra polimérica. Para isto, foram determinados o abatimento e a massa específica de cada concreto no estado fresco. No estado endurecido, foram realizados ensaios de absorção de água, índice de vazios, massa específica, resistência à compressão, Barcelona, tenacidade à flexão em prismas e tenacidade à punção em placas. Nas misturas com maiores teores de fibra não foi possível se obter a trabalhabilidade desejada, mesmo com a adição de superplastificante. Em alguns concretos, a macrofibra polimérica e a fibra de aço tiveram desempenhos equivalentes com relação à absorção, índice de vazios, resistência residual no Estado Limite Último (ELU) dos prismas e tenacidade das placas. O acréscimo do teor de macrofibra polimérica provocou alterações não significativas no valor do índice de vazios, da resistência residual em prismas e da tenacidade em prismas e placas. Foi encontrado uma equivalência entre os valores de tenacidade do concreto com menor teor de fibra de aço e do concreto com maior teor de macrofibra polimérica para a maioria das misturas. A macrofibra polimérica apresentou uma eficiência menor do que a fibra de aço quando utilizada no concreto destinado a pisos industriais. Além disso, o acréscimo do teor de macrofibra polimérica provocou pequenas alterações na espessura do piso industrial. / The fiber reinforced concrete (FRC) is a composite material mainly composed of hydraulic cement, fine and coarse aggregates, water and discontinuous fibers. The main purpose of the reinforcement in the concrete with fibers is the increase of the post-cracking resistant capacity of the composite, which reflects in the toughness gain. Traditionally, steel fibers, due to their high stiffness and tensile strength, are the most used for concrete reinforcement, while synthetic fibers are used to control the plastic shrinkage cracking of the composite. The polymeric macrofiber is a structural synthetic fiber that has spread in the Brazilian market in recent years, with few researches regarding its performance as a reinforcement element in concrete. Therefore, the use of the polymeric macrofiber in the concrete composition for structural purposes was evaluated in this study and the mechanical behavior of two fiber reinforced concrete matrices, one conventional and the other with high strength, with different contents of steel fiber and polymeric macrofiber, was analyzed. For this, the slump and the specific gravity of each concrete in the fresh state were determined. In the hardened state, water absorption, voids, specific gravity, compressive strength, Barcelona, flexural toughness in prisms and punching toughness in plates tests were performed. In the mixtures with higher fiber contents it was not possible to obtain the desired workability, even with the addition of superplasticizer. In some concretes, the polymeric macrofiber and the steel fiber had equivalent performances with respect to the absorption, voids, residual strength at Ultimate Limit State (ELU) of the beams and toughness of the plates. The increase of the polymeric macrofiber content did not cause significant changes in the value of the voids, residual strength in prisms and toughness in beams and plates. An equivalence of the toughness values of the concrete with lower content of steel fiber and the concrete with higher content of polymeric macrofiber was found for the majority of the mixtures. The polymeric macrofiber was less efficient than the steel fiber when used in concrete for industrial floors. In addition, the increase of the polymeric macrofiber content caused small changes in the thickness of the industrial floor.
52

Comportamento de pavimentos de concreto estruturalmente armados sob carregamentos estáticos e repetidos / Structurally reinforced concrete pavement behavior under static and cyclic loads

Patrícia Lizi de Oliveira Maggi 05 April 2004 (has links)
Apresenta-se um trabalho numérico e experimental, com o objetivo de estudar o comportamento dos pavimentos de concreto estruturalmente armados, quando submetidos a forças verticais estáticas e repetidas. Avalia-se a contribuição da armadura de flexão, na resistência de placas de concreto apoiadas sobre meio elástico. Verifica-se experimentalmente o modo de ruína de placas submetidas a carregamento monotônico e a carregamento repetido, com e sem armadura, e acompanha-se o desenvolvimento das fissuras no concreto e das deformações no aço. Comparam-se os resultados obtidos, com as recomendações da NBR 6118:2003, para o dimensionamento de estruturas submetidas à fadiga. É desenvolvido modelo numérico capaz de representar a interface do solo com a placa do pavimento, a fissuração do concreto, a contribuição da armadura e o comportamento pós-fissuração. Com auxílio do modelo numérico, validado a partir dos resultados experimentais, estuda-se a influência de alguns parâmetros importantes para o dimensionamento dos pavimentos, tais como: capacidade de suporte da fundação, espessura das placas, área de aço, dimensões das placas em planta, posição de aplicação da força e presença de juntas de transferência de deslocamento. Os resultados experimentais mostram uma significativa contribuição da armadura positiva na resistência de placas isoladas sob forças verticais centradas. Verificou-se que as forças repetidas provocam fadiga do aço e que o número de ciclos depende da deformação provocada na armadura. A partir dos resultados são traçadas diretrizes para o dimensionamento, no qual devem ser considerados os momentos positivos e os negativos, e deve ser feita a verificação da fadiga do concreto e da armadura / A numerical and experimental study on the behavior of structurally reinforced concrete pavement under vertical static and repeated load is presented. The contribution of bending reinforcement to the strength of concrete slab is assessed. It is experimentally verified the fracture of reinforced and plain concrete slabs under monotonic loads and under cyclic loads. The concrete cracking and the strain on steel are monitored. The results are compared to the brazilian code recommendations to the design of structures under fatigue. A numerical model that represents the soil-slab interface, the concrete cracking, the reinforcement contribution and the tension stiffening behavior is developed. Some important parameters to the pavement design are analyzed using this finite element model, whose reliability was verified to experimental results. These parameters are: the soil capacity; the slab thickness; reinforcement ratio; slab dimensions; load positions; and joints conditions. The tests data show an important contribution of the positive reinforcement on the strength of an isolated slab with centered load. It has been verified the fatigue of the steel. The number of cycles depends on the reinforcement strain. The results are used to propose some directions to the design. The positive and negative bending moments have to be considered and the fatigue on the concrete and on the reinforcement has to be verified
53

Avaliação do microclima interno de abrigos escamoteadores com diferentes tipos de pisos / Evaluation of the internal microclimate of piggy´s houses with different types of floors

Débora Caroline Gonçalves de Oliveira 15 April 2010 (has links)
O objetivo deste trabalho é avaliar o microclima interno de escamoteadores com diferentes formulações de placas cimentícias para o piso, aquecido com resistência elétrica. As placas de argamassa de cimento Portland tiveram por base o aproveitamento de resíduos agropecuários (cama sobreposta de suíno, fibra curta de sisal e casca de arroz) na sua confecção, em busca da melhoria nas propriedades físicas e mecânicas das placas. Essas matérias-primas serão utilizadas como material alternativo, na busca do reaproveitamento destes resíduos, que, na maioria das vezes, são descartados de forma errônea, prejudicando o meio ambiente. Esses resíduos foram caracterizados de forma a analisar sua potencialidade para a confecção das placas para piso de abrigo escamoteador. Foram confeccionados corpos-de-prova com seis diferentes tipos de formulações: referência de cimento Portland (C1), de CCSS em substituição a 30% em massa do cimento Portland (C2); de CCSS substituindo 30% de cimento Portland e fibras curtas de sisal substituindo 1,7% da massa da areia (C3); de CCSS substituindo 30% de cimento Portland e com casca de arroz substituindo 4% em massa de areia (C4); de cimento Portland com casca de arroz substituindo 4% da areia (C5); de cimento Portland com fibras curtas de sisal substituindo 1,7% da massa da areia (C6). Com base nos resultados dos ensaios físicos e mecânicos, as melhores formulações (C2, C3 e C4) foram escolhidas para a confecção das placas para o abrigo escamoteador. Para caracterização do ambiente, foram utilizados data-loggers para coleta de variáveis para determinação dos índices de conforto térmico: índice de temperatura de globo e umidade (ITGU), carga térmica radiante (CTR), entalpia (H), além dos índices analisou-se também a temperatura ambiental (TA) e a umidade relativa (UR). Os dias com menor valor de entalpia (H) foram considerados para análise comparativa dos índices de conforto, e os abrigos escamoteadores foram submetidos a quatro diferentes temperaturas de resistência (30, 35, 45 e 55 ºC). Os valores recome ndados para ITGU, CTR, H, TA e UR foram observados nos três diferentes tratamentos com a temperatura da resistência elétrica acima de 35ºC. Os resultado s obtidos validaram o destino alternativo a CCSS, a fibra de sisal e a casca de arroz, como materiais viáveis para utilização em placas de piso para abrigos escamoteadores com aceitável desempenho térmico, físico e mecânico. / The objective of this study is to evaluate the internal microclimate of piggy\'s houses with different formulations of cementitious boards for the floor, warmed with electrical resistance. The boards of ordinary Portland cement mortar were based on the use of agricultural residues (swine deep bedding, short-fiber sisal and rice husk) in its production, in search of improvement in physical and mechanical properties of the plates. These raw materials will be used as alternative materials searching reuse of waste, which in most cases are disposed of wrongly, harming the environment. These wastes were characterized in order to assess was potential for making the plates for floor piggy\'s houses. Samples were prepared with six different types of formulations: reference ordinary Portland cement (OPC) (C1), replacement of OPC by 30% by weight of ashes swine deep bedding (ASDB) (C2); replacement of OPC by 30% of ASDB and fiber short sisal replacing 1.7% of the mass of sand (C3); replacement of OPC by 30% of ASDB and rice husk replacing 4% by mass of sand (C4); OPC with rice husk replacing 4% of the sand (C5); OPC with short sisal fibers replacing 1.7% of the sand (C6). Based on the results of the mechanical and physical tests, the best formulations (C2, C3 and C4) were chosen for the preparation of the floor plates in the piggy\'s houses. To characterize the environment, data-loggers were installed for the collection of variables to determine the thermal comfort indices: black globe temperature and humidity index (BGHI), radiant heat load (RHL), enthalpy (H), ambient temperature (AT) and relative humidity (RH). The days with lower values of enthalpy (H) were considered for comparative analyses of the comfort indices, and piggy\'s houses were subjected to four different temperatures of electric resistance (30, 35, 45 and 55ºC). The recommended v alues for BGHI, RHL, H, AT and RH were achieved in the three different treatments with temperature of electric resistance above 35ºC. The results validat ed the alternative destination to ASDB, sisal fiber and rice husks as viable material for use in floor plates piggy\'s houses with acceptable thermal, physical and mechanical performance.
54

Estudo teórico-experimental da contribuição da armadura para a capacidade resistente de vigas parcialmente revestidas / A theoretical and experimental study of steel bars contribution of the bending capacity of the partially encased composite beams

Leandro de Amorim Cavalcanti 26 March 2010 (has links)
Este trabalho tem por objetivo investigar a contribuição da armadura para a capacidade resistente de vigas mistas parcialmente revestidas, bem como sua eficiência para promover o comportamento conjunto aço-concreto, imprescindível para a obtenção de vigas mistas. O estudo engloba uma investigação experimental com ensaios de vigas sob flexão em quatro pontos e uma simulação numérica utilizando o pacote computacional DIANA®, visando obter dados do comportamento de vigas mistas parcialmente revestidas com armadura longitudinal. Foram ensaiados quatro modelos de viga mista parcialmente revestida e duas variáveis foram analisadas: taxa de armadura longitudinal no concreto e posição dos conectores tipo pino com cabeça. Os resultados experimentais mostraram a eficiência do conjunto armadura-conector para o aumento da capacidade resistente à flexão e para a promoção da interação aço-concreto. A simulação numérica teve concordância satisfatória com os resultados experimentais obtidos. / This study aims to investigate the contribution of the steel bars to the flexure capacity and to promote the composite behavior in partially encased composite beams. The study includes an experimental investigation of partially encased beams under bending in four points and a numerical simulation using the computer package DIANA® to collect data from the behavior of partially encased composite beams with longitudinal reinforcement. Four models of partially encased composite beams were tested and two variables were analyzed: rate of longitudinal reinforcement in concrete and position of stud bolts. The experimental results showed the efficiency of the junction between reinforcing bars and stud bolt to the increase the bending capacity of the partially encased beam and to obtain the steel-concrete interaction. The numerical simulation has good agreement with the experimental results.
55

Análise teórico-experimental de pisos mistos de pequena altura / Experimental and theorical analysis of composite shallow floors

Juliana Teodoro Friedrich 13 August 2012 (has links)
O piso misto usual é formado pela laje mista, de aço e concreto, apoiada na mesa superior da viga metálica. No piso misto de pequena altura, a laje mista se apoia na mesa inferior da viga, diminuindo assim a altura total do piso. A forma de aço, utilizada nesse sistema, tende a ser três vezes mais alta, que as formas de aço usuais. No Brasil não há uma forma de aço para uso nos sistemas mistos de pequena altura, comercializada. Este estudo trata do desenvolvimento de uma forma de aço trapezoidal para pisos mistos de pequena altura. Foi desenvolvida uma geometria de forma de aço trapezoidal com mossas estampadas nas laterais. Foram realizados ensaios experimentais com modelos de lajes mistas, confeccionados com a forma de aço desenvolvida no presente estudo. Esses ensaios visaram avaliar a resistência e o comportamento de lajes mistas fabricadas com a forma desenvolvida. A geometria da forma de aço e das mossas apresentaram um bom comportamento frente aos esforços cisalhantes, com resistências comparáveis as formas de aço comercializadas, mostrando que podem ser utilizadas em trabalhos futuros. / The usual composite floor is formed by the composite slab, of steel and concrete, supported on the top flange of the steel beam. On the shallow floor systems, the steel beams are contained within the depth occupied by the floor. The steel form steel used in this composite shallow floor systems is around three times higher than usual forms of steel decking. In Brazil there is not a form of steel for use in shallow floor systems, marketed. This study concerns the development of a steel decking to shallow floor systems. Developed a geometry shape of trapezoidal steel and embossements on the sides. Experimental tests were conducted with composite slabs, made of steel the shape developed in this study. These tests were intended to assess the strength and behavior of composite slabs made with the developed form. The geometry of the steel form and embossements showed good behavior against shearing efforts, forms with resistances comparable steel deckings marketed, showing that may be used in future work.
56

Estudo de eficiência da ventilação em sistema de climatização com distribuição de ar pelo piso. / Ventilation effectiveness study of an underfloor air distribution system.

Renata Maria Marè 21 May 2010 (has links)
A aplicação de sistemas de climatização com distribuição de ar pelo piso tem aumentado em países desenvolvidos, o que também tem ocorrido no Brasil. Em paralelo, tem crescido o interesse pela qualidade do ar interior e os seus efeitos no bem estar, saúde e produtividade dos ocupantes de uma edificação. Diversos estudos têm apontado para as vantagens deste sistema em relação à remoção de contaminantes do ambiente interior. Este sistema tem figurado nos programas de certificação ambiental de edificações como uma alternativa vantajosa para a melhoria da qualidade do ar interior e o conforto térmico com preservação da eficiência energética, recebendo pontuação adicional. Com o crescente interesse por este tipo de sistema, estudos que aprimorem o seu projeto visando à melhor eficiência global mostram-se essenciais. Este estudo tem como principal objetivo verificar experimentalmente a contribuição de um sistema de climatização com distribuição de ar pelo piso para a qualidade do ar interior de um ambiente, sendo este uma sala de aula para 48 alunos situada no Departamento de Engenharia de Construção Civil da Escola Politécnica da Universidade de São Paulo, em condições reais de uso. Para isso, foram medidas as concentrações de partículas em suspensão na zona de respiração para pessoas sentadas (a 1,10 m do piso), e no retorno do ar (a 2,60 m do piso) simultaneamente, sob seis diferentes valores de temperatura do ar na zona ocupada (a 0,60 m do piso), previamente escolhidos. Estas concentrações permitiram o cálculo e a análise do índice de efetividade na remoção de contaminantes IERC no ambiente, para partículas e CO2 (segunda etapa das medições). Simultaneamente, foram realizadas medições de variáveis de conforto térmico no ambiente, temperatura do ar e velocidade do ar, em seis diferentes alturas e quatorze pontos do ambiente. As baixas concentrações de partículas em suspensão (inferiores a 0,035 mg/m³) mostraram que este sistema não dispersa contaminantes no ar interior. Os IERC próximos ou superiores à unidade em todas as condições de operação do sistema, tanto para partículas em suspensão como para CO2, comprovaram a sua eficiência na remoção de contaminantes do ambiente interior. / The use of underfloor air distribution (UFAD) systems is growing in developed countries, and this is also observed in Brazil. Besides, the interest in indoor air quality and its effects on the well being, health and productivity of the occupants in a building is an important issue nowadays. Many studies have related the advantages of UFAD systems in removing indoor air contaminants from the ambient as compared to overhead systems. In the building certification systems, they figure as good alternatives to promote better indoor air quality and thermal comfort, preserving energy efficiency, which corresponds to additional points. With the expanding interest in this technology, studies that enhance its project, keeping as a goal its global efficiency, are very welcome. The aim is to experimentally verify the contribution of an UFAD system to the indoor air quality of a classroom used by 48 students at the Civil Construction Department of the Engineering School of the University of São Paulo Brazil. The study has been conducted in a non-steady state condition. In order to perform this evaluation, the levels of indoor air-borne particles were measured at the breathing zone for seated people (1.10m from the ground), and at the exhaust (2.60m from the ground) simultaneously, under six different pre-defined values of air temperature at the occupied zone (0.60m from the ground). These concentration levels have allowed calculating the contaminant removal effectiveness index, CRE, in many points of the ambient. A similar analysis was developed for the concentrations of CO2 in the second part of the experiment. At the same time, the air temperature and air velocity were measured in six different levels and at fourteen points of the ambient. The low concentration levels of total suspension particle (under 0.035 mg/m³) have shown that this system doesn\'t disperse air contaminants indoors. The CRE indexes near or above 1.0, for both total suspension particle and CO2, have confirmed the ventilation effectiveness of this underfloor air distribution system under all the operational conditions.
57

[en] STUDY OF A MODIFIED STUB-GIRDER FLOOR SYSTEM / [pt] ESTUDO DE UM SISTEMA DE VIGAMENTO DE PISO TIPO STUB-GIRDER MODIFICADO

ANTONYONY CARLOS JORDAO HEITOR 22 March 2018 (has links)
[pt] Este estudo tem por objetivo avaliar o comportamento estrutural de um sistema de vigamento de piso tipo stub-girder, modificado para melhor aproveitamento dos perfis em sua fabricação. O estudo é baseado em formulações não lineares a partir do método dos elementos finitos (MEF), com uso do software ANSYS. Através do software FTOOL foi criado um modelo simplificado para a análise estrutural e o cálculo das resistências nominais foi feito com base na norma canadense CAN-S16-10 da Canadian Standards Association. Além disso, foram avaliadas as cargas de máximas e de serviço do sistema, bem como os deslocamentos associados a estes carregamentos. Com base nos resultados obtidos, foram feitas recomendações de projeto do sistema e foram avaliadas as condições de economia de material e possibilidade de utilização na prática de construção de edificações de andares múltiplos. Com vistas à fase de construção, é feita a discussão sobre a possibilidade de obtenção de um método construtivo industrializado, já que o sistema de fabricação é caracterizado pela rapidez de produção e montagem, que são facilitadas pelo fato deste sistema permitir a reutilização de pequenos comprimentos de perfis que sobram no processo normal de fabricação. / [en] This study s purpose was to evaluate the structural behavior of a stub-girder floor-system, which was modified to better utilize the steel profiles in its manufacturing process. The study is based on nonlinear analysis through the use of the finit element method (FEM), employing the software ANSYS. For the structural analysis, a simplified model was created through the use of the software FTOOL and the nominal resistances was obtained based on the canadian CAN-S16-10 Standard, by the Canadian Standards Association. Furthermore, the working and tensile loads were evaluated, as were the displacements associated to them. Based on the results, designs recommendations were made and the conditions of economy of material, as well the possibility of the system s practical use in multi-storey buildings were discussed. With regards to the construction phase, a discussion was made on the possibility of obtaining an industrialized construction method, since the manufacturing process is characterized by the fast production and assembly, which are facilitade by the fact that this system allows the reuse of small lenghts of remaining profiles from the normal manufacturing process.
58

Avaliação da qualidade ambiental interior de um edifício climatizado artificialmente com ênfase na análise do conforto térmico / Evaluation of indoor environmental quality of an artificially conditioned building, focusing on thermal comfort analysis

Silva, Ana Flávia Silveira 25 November 2010 (has links)
Ocupantes de ambientes internos climatizados artificialmente estão expostos contínua e prolongadamente a condições ambientais muitas vezes desfavoráveis à execução de suas atividades e à manutenção da saúde. O objetivo desta pesquisa foi avaliar alguns parâmetros de qualidade do ar interior e de conforto térmico de um edifício climatizado artificialmente e relacioná-los à utilização de sistema de condicionamento de ar com distribuição pelo piso em ambientes que não são caracterizados como escritórios abertos. Considerando que o edifício estudado apresenta usos distintos de seus pavimentos, optou-se pela avaliação de dois deles, um pavimento cujo layout é de salas de aula e outro de escritório semi-aberto. Os parâmetros foram analisados em três momentos distintos. O primeiro se caracteriza por três ciclos semestrais de medições de temperatura, umidade relativa e velocidade do ar, concentração de aerossóis, dióxido de carbono e fungos. A segunda etapa consiste em uma campanha única de medições, com duração de quatro dias, permitindo a realização de perfis de temperatura e umidade relativa, avaliação das velocidades do ar em pontos de desconforto e cálculo dos índices de conforto térmico PMV (Predicted Mean Vote) e PPD (Predicted Percentage of Dissatisfied). Em um terceiro e último momento, aplicou-se o questionário de qualidade ambiental interior aos ocupantes de ambos os pavimentos. Resultados obtidos nos ciclos permitiram identificar concentrações de fungos e dióxido de carbono acima dos limites indicados. Os perfis de temperatura revelaram a predominância das mesmas abaixo do recomendado. O cálculo dos índices PMV e PPD apontaram para um cenário de maior conforto térmico nos ambientes estudados com temperatura operativa igual a 24 graus Celsius. Os resultados dos questionários corroboraram as medições de temperatura, indicando a prevalência das sensações térmicas relacionadas ao frio entre os ocupantes do edifício, em especial aqueles do sexo feminino. Ficou evidenciado que o conforto térmico nos ambientes pesquisados é um fator perturbador das atividades exercidas em ambos os pavimentos. Houve um grande número de relatos de ocupantes com sintomas típicos da Síndrome dos Edifícios Doentes (SED), sugerindo que medidas relativas à qualidade ambiental devem ser tomadas em prol da saúde, bem estar e produtividade dos ocupantes do edifício. Concluiu-se que a operação e manutenção do sistema de condicionamento de ar com insuflamento pelo piso em ambientes distintos de escritórios abertos são mais complexas e, por isso, dificultam o alcance de uma qualidade ambiental interior satisfatória. / Occupants of artificially conditioned indoor spaces are continuously and lengthily exposed to environmental conditions mostly adverse to their activities performance and health maintenance. The purpose of this research was to evaluate some indoor air quality and thermal comfort parameters of an artificially conditioned building, and relate them to the employment of underfloor air conditioning system in spaces that differ from open-plan office spaces. Considering the studied building presents different activities on each of its floors it was necessary to choose two of them, one characterized by classrooms layout and the other by a semi open-plan office layout. The on-site data collection took place in three different steps. Step one was distinguished by three six-month cycles of air temperature, relative humidity and air velocity measurements, and fungi, particulate matter and carbon dioxide concentrations. The second step consisted of a four-day single campaign of measurements, when air temperature and relative humidity profiles were carried out, air velocity was quantified in complaining areas, and the Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD) thermal comfort indexes were determined. During the third and last step, indoor environmental quality questionnaire surveys were distributed to the occupants of both studied floors. Data analysis and assessment originated from the cycles identified exceeding fungi and carbon dioxide concentrations. Temperature profiles indicated their prevalence below the recommended range. PMV and PPD indexes determination pointed to a scenery of best thermal environmental conditions for the researched spaces, with an operative temperature of 24 Celsius degrees. The results of the questionnaire surveys supported the air temperature measurements, showing supremacy of cold related thermal sensations among the occupants, especially those of female gender. It was evident that the thermal comfort of the studied environments is a disturbing factor for the activities practiced on both floors. There was a great number of occupants reporting Sick Building Syndrome (SBS) typical symptoms, what suggested actions related to indoor environmental quality should be taken in order to provide the desired health, welfare and productivity for the building occupants. It was conclusive that the operation and maintenance of underfloor air conditioned systems in indoor environments unlike open-plan offices are more complex and therefore make it harder to reach an acceptable indoor environmental quality.
59

Contribuição ao projeto de estruturas multi-piso reticuladas em concreto pré-moldado / Contribution to the design of precast concrete multi-storey structures

Mota, Joaquim Eduardo 21 October 2009 (has links)
Estruturas em concreto pré-moldado vêm sendo utilizadas com freqüência em sistemas reticulados do tipo multi-piso, destinados às mais variadas atividades como: estabelecimentos comerciais, estacionamentos, escolas, hospitais e etc. A utilização de ligações viga-pilar do tipo semi-rígida constitui uma alternativa interessante para o enrijecimento e para a garantia da estabilidade global deste tipo de estrutura. Atualmente, a rigidez e a resistência destas ligações têm sido determinadas por ensaios de modelos em escala real. Estes ensaios, além de apresentarem um custo elevado, têm aplicação restrita à ligação examinada o que torna esta metodologia limitada e não adequada à prática de elaboração de projeto. Apresenta-se, neste trabalho, um modelo mecânico para determinação numérica da relação força-deslocamento de uma ligação viga-pilar semi-rígida a partir da contribuição da rigidez individual de cada componente de transferência de força utilizado na vinculação. A formulação do equilíbrio do modelo é implementada em planilha eletrônica constituindo-se numa ferramenta de cálculo para o projetista, permitindo o estudo, de forma rápida e amigável, da influência do posicionamento e da rigidez individual de cada componente de transferência de força na rigidez e na resistência da ligação. Este modelo mecânico foi utilizado para o cálculo da rigidez à rotação para momento fletor positivo de uma ligação viga-pilar ensaiada em laboratório. Os valores para a rigidez da ligação obtidos em ensaio e pelo modelo mecânico ficaram muito próximos. Da formulação do equilíbrio do modelo mecânico pode-se extrair ainda uma matriz de rigidez que é utilizada na representação da ligação semi-rígida no modelo de barra da estrutura. Um programa computacional foi desenvolvido para a análise de pórticos planos com ligação viga-pilar semi-rígida considerando ainda as não linearidades físicas e geométricas do modelo de cálculo. O programa foi validado pela comparação de resultados de exemplos também processados no programa ANSYS. A não-linearidade geométrica é considerada pelo método modal, não incremental-iterativo, e que obtém a parcela não-linear da resposta estrutural pela combinação dos seus modos de flambagem. A não-linearidade física do concreto é considerada pelo método da rigidez secante no qual a rigidez de cada barra da estrutura é reduzida na análise conforme suas armaduras e o nível de sua solicitação. Para o cálculo da rigidez secante dos pilares desenvolveu-se um programa que permite a consideração de armaduras ativas e passivas na seção. A análise de alguns exemplos revelou que a protensão dos pilares é também uma alternativa interessante para o enrijecimento da estrutura. Além de exemplos práticos, outros temas pertinentes ao projeto deste tipo de estrutura como: estabilidade na fase construtiva, esforços finais após a montagem, efeitos dependentes do tempo, assimetria de rigidez e plastificação das ligações, são também abordados no trabalho. / Precast concrete multi-storey structures have been more frequently used to construct commercial buildings, parking, schools and hospitals. The use of semi-rigid beam-tocolumn connections is a good strategy to guarantee the global stability of this type of structure. Actually the rigidity and the strength of this type of connection are obtained in an experimental program using full scale prototypes. This procedure is not only expensive but limited and not adequate for design since the results are only valid for the examined connection. This research presents a mechanical model used to determine numerically the force-displacement relationship of a beam-to-column semirigid connection. The procedure uses the contribution of any individual force transfer component active in the connection. The equilibrium equation of the model is implemented in an electronic-worksheet where the designer can rapidly and friendly study the influence of the position and the individual rigidity of each force transfer component in the global rigidity and strength of the connection. For validation, this procedure was used to calculate the flexural rigidity for positive bending moment of a beam-to-column semi-rigid connection that was tested in laboratory. The numerical values of the connection rigidity obtained by test and by the mechanical model are very close. The matrix used in the formulation of the mechanical model equilibrium can also be used to represent the semi-rigid connection in the finite element model of the structure. A computational program was developed for plane frame analysis including semi-rigid beam-to-column connections and both physical and geometric nonlinearities. The program was tested by comparing the results of some examples that are also analysed in the ANSYS program. The geometric nonlinearity is considered by a modal method where the nonlinear response of the structure is obtained by a combination of its buckling modes. The physical nonlinearity of the concrete is considered by the secant rigidity method. In this method the rigidities of all concrete bars in the structure are reduced by coefficients that depend of the reinforcement in the cross section and the level of the efforts. A special computational program was developed to calculate the secant rigidity for a concrete cross section with reinforcing bar and prestressing steel. The analysis of some examples shows that the use of prestressing steel in collums is also an interesting alternative to sttifen the structure. Beyond of some practical examples, others themes related to the design of this type of structure like: stability in the erection process, efforts in the end of the erection process, time-dependent effects, non symmetrical and plastic behavior of the connections, are also treated in this work.
60

Análise teórica e experimental de pisos mistos de pequena altura compostos por vigas metálicas e lajes alveolares de concreto / Theoretical and experimental analysis of slim floor systems composed by steel beam and concrete hollow core slabs

Souza, Patricia Tavares de 22 March 2016 (has links)
No mercado mundial existe uma visível tendência de tornar as obras mais industrializadas e racionalizadas com o objetivo de reduzir os desperdícios, acelerar a velocidade de execução das obras e garantir maior qualidade às mesmas. A adoção de elementos estruturais com certo grau de industrialização pode trazer benefícios em relação aos custos, à mão de obra, ao tempo de execução e ao impacto ambiental. Neste contexto, as estruturas mistas de aço e concreto satisfazem essa necessidade, pois tanto os elementos de aço quanto os elementos de concreto podem ser pré-fabricados, ficando apenas as etapas de içamento e montagem a serem realizadas na obra, reduzindo o uso de fôrmas e escoramentos. Os pisos mistos de aço e concreto de pequena altura caracterizam-se pelo embutimento da laje de concreto na altura do perfil de aço, sendo a principal vantagem, em relação ao piso misto convencional, a redução da altura total do composto. Portanto, este trabalho tem como objetivo analisar o comportamento de pisos mistos de aço e concreto de pequena altura com laje alveolar em concreto protendido por meio de ensaios de cisalhamento direto (push-out test) e de flexão. Na solução proposta, a transferência de esforços entre o perfil de aço e a laje alveolar foi feita por meio de conectores tipo pino com cabeça e concreto moldado no local. Os resultados demonstraram-se promissores em termos de comportamento do piso misto de pequena altura, aumentando significativamente a rigidez do sistema em relação à viga de aço isolada. Em complemento, foi desenvolvida uma simulação numérica dos modelos físicos ensaiados utilizando o pacote computacional DIANA®, fundamentado no método dos elementos finitos, na qual o modelo numérico representou adequadamente o comportamento dos pisos mistos de pequena altura, permitindo análises paramétricas. / On the world market, there is a visible tendency to turn buildings construction more industrialized and rationalized in order to reduce waste, accelerate the construction speed and ensure higher quality to them. The adoption of structural elements with a degree of industrialization can bring benefits regarding costs, labor, construction time and environmental impact. In this context, steel and concrete composite structures satisfy this need, since steel and concrete elements can be prefabricated, with only lifting and mounting steps to be performed on site, reducing use of formwork and shoring. A type of slim floor system consists in precast concrete hollow core slabs supported on the lower flange of steel beams. The major advantage of this solution, compared to conventional composite beam, is reducing the overall height of the floor. Therefore, this study aims to analyze the behavior of slim floor with prestressed concrete hollow core slabs through push-out and bending tests. In the proposed solution, the transfer of forces between steel beam and hollow core slabs was made by stud bolts and cast on site concrete. The obtained results proved to be promising in terms of slim floor behavior, significantly increasing the system stiffness regarding the isolated steel beam. In addition, a numerical modeling of the studied slim floor system was developed, using finite element based software DIANA®, in which the numerical model adequately represented the behavior of the composite beam, allowing parametric analysis.

Page generated in 0.0589 seconds