• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 4
  • Tagged with
  • 41
  • 23
  • 16
  • 13
  • 12
  • 10
  • 10
  • 10
  • 10
  • 10
  • 9
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Desenvolvimento de detector de neutrons usando sensor tipo barreira de superficie com conversor (n,p) e conversor (n,alpha)

MADI, TUFIC 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:27Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:10Z (GMT). No. of bitstreams: 1 06629.pdf: 11734475 bytes, checksum: 26ac38190c26794def0e5ba95d87d535 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
32

Avaliação do desempenho de embalagens para alimentos quando submetidas a tratamento por radiação ionizante

MOURA, ESPERIDIANA A.B. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:47Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:50Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
33

Hidrógeis poliméricos com nanopartículas de prata para aplicações médicas / Polymeric hydrogels with silver nanoparticles for medical applications

ALCANTARA, MARA T.S. 03 March 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-03-03T10:48:26Z No. of bitstreams: 0 / Made available in DSpace on 2015-03-03T10:48:26Z (GMT). No. of bitstreams: 0 / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
34

Desenvolvimento de detector de neutrons usando sensor tipo barreira de superficie com conversor (n,p) e conversor (n,alpha)

MADI, TUFIC 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:27Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:10Z (GMT). No. of bitstreams: 1 06629.pdf: 11734475 bytes, checksum: 26ac38190c26794def0e5ba95d87d535 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
35

Avaliação do desempenho de embalagens para alimentos quando submetidas a tratamento por radiação ionizante

MOURA, ESPERIDIANA A.B. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:47Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:50Z (GMT). No. of bitstreams: 0 / No presente trabalho foram estudadas as propriedades mecâncias (resistência à tração e porcentagem de alongamento na ruptura e resistência à perfuração), propriedades ópticas, permeabilidade ao gás oxigênio e ao vapor d\'água, migração total em simulante aquoso (ácido acético 3%) e gorduroso (n- heptano), e a formação de produtos voláteis da radiólise, com vistas à avaliar o efeito da radiação ionizante (raios gama e feixe de elétrons) em filmes flexíveis mono e multicamadas comerciais, fabricados no Brasil para a indústria de produtos cárneos. Os filmes estudados foram: um monocamada de polietileno de baixa densidade (LDPE) e um multicamadas coextrusado composto de polietileno de baixa densidade (LDPE), copolímero de etileno e álcool vinílico (EVOH) e poliamida (PA), ou seja, a estrutura: LDPE/EVOH/PA. As irradiações foram realizadas em uma fonte de 60Co do tipo Gammacell e em um acelerador de elétrons do tipo eletrostático (l,5MeV), com doses de até 30 kGy, na temperatura ambiente e presença de ar. As alterações nas propriedades foram avaliadas de acordo com a dose de radiação aplicada, oito dias após a irradiação e novamente, dois a três meses após a irradiação. Os resultados mostraram que as reações de cisão predominaram sobre as reações de reticulação para ambos os filmes estudados, irradiados com raios gama ou com feixe de elétrons. As variações observadas em função da irradiação, nas propriedades avaliadas não limitam a aplicação final desses filmes, uma vez que não ultrapassaram o limite de segurança especificado pelo fabricante em nenhuma dose e período em que foram estudadas. Concluiu-se que os filmes estudados podem ser utilizados, sob o ponto de vista das propriedades avaliadas, como embalagens para produtos pasteurizáveis por radiação e radioesterilizáveis usando irradiadores gama ou aceleradores de elétrons, nas doses de radiação estudadas. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
36

Hidrógeis poliméricos com nanopartículas de prata para aplicações médicas / Polymeric hydrogels with silver nanoparticles for medical applications

ALCANTARA, MARA T.S. 03 March 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-03-03T10:48:26Z No. of bitstreams: 0 / Made available in DSpace on 2015-03-03T10:48:26Z (GMT). No. of bitstreams: 0 / O desenvolvimento de novos procedimentos e tecnologias tem proporcionado um grande avanço no tratamento de feridas e queimaduras, melhorando a qualidade de vida das vítimas e reduzindo as taxas de mortalidade de pessoas com queimaduras graves. Entretanto as complicações infecciosas continuam sendo um desafio e uma das principais causas de óbito de queimados. Por outro lado, em todo o mundo tem-se observado um crescente interesse no uso de hidrogéis para aplicação como curativos para queimaduras, ferimentos e úlceras de pele, tendo em vista que são capazes de absorver exsudatos, ajudam na cicatrização e proporcionam conforto ao paciente, uma vez que favorecem o alívio da dor. Além disso, os hidrogéis também podem ser aplicados como matrizes para sistemas de liberação controlada de princípios ativos e agentes antimicrobianos. O objetivo deste trabalho foi estudar as propriedades mecânicas e físico-químicas de hidrogéis compostos por blendas formadas por Poli(N-vinil-2-pirrolidona)/ Polietilenoglicol/ ágar (PVP/PEG/ágar), Poli(N-vinil-2-pirrolidona)/ glicerol/ ágar (PVP/glicerol/ágar); Poli(álcool vinílico)/ kappa-carragena/ ágar (PVA/KC/ágar), reticuladas por radiação ionizante. Para a preparação das blendas, utilizou-se planejamento de misturas como ferramenta, oferecendo assim subsídios a futuros desenvolvimentos de novos hidrogéis, que possam ser usados como curativos e como matrizes poliméricas para liberação de ativos hidrofílicos e lipofílicos. Foram otimizadas três formulações e sintetizadas seis, três das quais hidrogéis nanocompósitos de prata. As nanopartículas de prata (NPAg) foram sintetizadas, in situ, por radiação gama, sem uso de catalisadores ou outro reagente para obtenção de curativo mais puro e com ação antimicrobiana. A caracterização físico-química dos hidrogéis foi obtida por análises de fração gel, intumescimento, ensaios de tração e perfuração, microscopia eletrônica de varredura (MEV), espectroscopia na região do ultravioleta-visível (UV-vis). Também foi avaliada a atividade antimicrobiana dos hidrogéis e realizado estudo de citotoxicidade in vitro. O planejamento de misturas apresentou modelos confiáveis para os resultados de fração gel e intumescimento, porém, para as propriedades mecânicas, os resultados devem ser vistos com cautela. O uso da radiação se mostrou eficaz para a síntese de NPAg in situ nas blendas estudadas. Os resultados sugerem que os hidrogéis sintetizados não liberaram NPAg, porém os hidrogéis de PVP apresentaram atividade bactericida para S. aureus e P. Aeruginosa, enquanto que o hidrogel de PVA apresentou atividade bactericida para P. aeruginosa e atividade bacteriostática para S. aureus, sendo essa atividade pelo contato direto. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
37

Geometrical dependence of viscosity of polymethylmethacrylate melt in capillary flow

Lin, X., Kelly, Adrian L., Ren, D.Y., Woodhead, Michael, Coates, Philip D., Wang, K.S. January 2013 (has links)
No / The shear viscosity of polymethylmethacrylate (PMMA) melt is particularly investigated by using a twin-bore capillary rheometer at four temperatures of 210, 225, 240, and 255 degrees C with different capillary dies. Experimental results show that the geometrical dependence of shear viscosity is significantly dependent on melt pressure as well as melt temperature. The measured shear viscosity increases with the decrease of die diameter at lower temperatures (210 and 225 degrees C) but decreases with the decrease of die diameter at higher temperatures (240 and 255 degrees C). Based on the deviation of shear viscosity curves and Mooney method, negative slip velocity is obtained at low temperatures and positive slip velocity is obtained at high temperatures, respectively. Geometrical dependence and pressure sensitivity of shear viscosity as well as temperature effect are emphasized for this viscosity deviation. Moreover, shear viscosity curve at 210 degrees C deviates from the power law model above a critical pressure and then becomes less thinning. Mechanisms of the negative slip velocity at low temperatures are explored through Doolittle viscosity model and Barus equation, in which the pressure drop is used to obtain the pressure coefficient by curve fitting. Dependence of pressure coefficient on melt temperature suggests that the pressure sensitivity of shear viscosity is significantly affected by temperature. Geometrical dependence of shear viscosity can be somewhat weakened by increasing melt temperature. (c) 2013 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 130: 3384-3394, 2013
38

Avaliação do desempenho de embalagens para alimentos quando submetidas a tratamento por radiação ionizante / Evaluation of performance of food packagings when treated with ionizing radiation

Moura, Esperidiana Augusta Barretos de 07 March 2006 (has links)
No presente trabalho foram estudadas as propriedades mecâncias (resistência à tração e porcentagem de alongamento na ruptura e resistência à perfuração), propriedades ópticas, permeabilidade ao gás oxigênio e ao vapor d\'água, migração total em simulante aquoso (ácido acético 3%) e gorduroso (n- heptano), e a formação de produtos voláteis da radiólise, com vistas à avaliar o efeito da radiação ionizante (raios gama e feixe de elétrons) em filmes flexíveis mono e multicamadas comerciais, fabricados no Brasil para a indústria de produtos cárneos. Os filmes estudados foram: um monocamada de polietileno de baixa densidade (LDPE) e um multicamadas coextrusado composto de polietileno de baixa densidade (LDPE), copolímero de etileno e álcool vinílico (EVOH) e poliamida (PA), ou seja, a estrutura: LDPE/EVOH/PA. As irradiações foram realizadas em uma fonte de 60Co do tipo Gammacell e em um acelerador de elétrons do tipo eletrostático (l,5MeV), com doses de até 30 kGy, na temperatura ambiente e presença de ar. As alterações nas propriedades foram avaliadas de acordo com a dose de radiação aplicada, oito dias após a irradiação e novamente, dois a três meses após a irradiação. Os resultados mostraram que as reações de cisão predominaram sobre as reações de reticulação para ambos os filmes estudados, irradiados com raios gama ou com feixe de elétrons. As variações observadas em função da irradiação, nas propriedades avaliadas não limitam a aplicação final desses filmes, uma vez que não ultrapassaram o limite de segurança especificado pelo fabricante em nenhuma dose e período em que foram estudadas. Concluiu-se que os filmes estudados podem ser utilizados, sob o ponto de vista das propriedades avaliadas, como embalagens para produtos pasteurizáveis por radiação e radioesterilizáveis usando irradiadores gama ou aceleradores de elétrons, nas doses de radiação estudadas. / In this study the mechanical properties (tensile strength and percentage elongation at break and penetration resistance), optical properties, gas oxygen and water vapor permeability, the overall migration tests into aqueous food simulant (3% aqueous acetic acid) and fatty food simulant (n-heptane), as well as the formation of volatile radiation product tests were used to evaluate the effects of ionizing radiation (gamma irradiation or electron-beam irradiation) on commercial monolayer and multilayer flexible plastics packaging materials. These films are two typical materials produced in Brazil for industrial meat packaging, one of them is a monolayer low-density polyethylene (LDPE) and other is a multilayer co extruded low-density polyethylene (LDPE), ethylene vinyl alcohol (EVOH), polyamide (PA) based film (LDPE/EVOH/PA). Film samples were irradiated with doses up to 30 kGy, at room temperature and in the presence of air with gamma rays using a 60Co facility and electron beam from 1.5 MeV electrostatic accelerator. Alterations of these properties were detected according to the dose applied initially eight day after irradiation took place and new alterations of these values when the properties were evaluate two to three months after irradiation process. The results showed that scission reactions are higher than cross-linking process for both studied films, irradiated with gamma rays and electron beam. The evaluated properties of the irradiated films were not affected significantly with the dose range and period studied. The monolayer Unipac PE-60 and the multilayer Lovaflex CH 130 films can be used as food packaging materials for food pasteurization and in the sterilization process of by ionizing radiation using a gamma facilities and electron beam accelerators in commercial scale.
39

"Avaliação dos efeitos da adição do polietilenoglicol ao surfactante pulmonar exógeno na função pulmonar, em um modelo experimental de síndrome de desconforto respiratório tipo agudo" / Lungs mechanisms and pulmonary function evaluation after polyethyleneglycol addition to the exogenous surfactant in an experimental model of ARDS

Freddi, Norberto Antonio 22 September 2005 (has links)
O surfactante pulmonar é uma substância fundamental na mecânica pulmonar, com atividade biofísica e de proteção alveolar por reduzir a tensão superficial e impedir o seu colabamento.Na síndrome do desconforto respiratório tipo agudo(SDRA) ocorre uma diminuição quantitativa e disfunção qualitativa do surfactante com agravamento do quadro clínico.Estudamos, em um modelo experimental de SDRA em coelho adulto, os efeitos da adição de polietilenoglicol ao surfactante pulmonar exógeno quanto à melhora da complacência pulmonar,pressão ventilatória,índice de oxigenação,diferença alvéolo-arterial de oxigênio,gradiente alvéolo-arterial de oxigênio pressão arteial parcial de CO2, pelo índice de eficiência ventilatória,diâmetro alveolar médio e índice de distorção.A utilização do surfactante melhorou a oxigenação, e a mecânica pulmonar, sem no entanto, haver diferença entre os grupos surfactante e surfactante mais polietilenoglicol / Lung surfactant is a fundamental substance in lung mechanics, with biophysical activity to reduce alveolar surface tension and to avoid pulmonary collapse. In the acute respiratory distress syndrome (ARDS) occurs a quantitative and qualitative surfactant dysfunction with worsening of clinical status. We study, in an experimental model of ARDS in adult rabbit, the effects of polyethyeneglycol addition to the exogenous surfactant to improve the pulmonary compliance, ventilatory pressure, oxygenation index, arterial-alveolar oxygen ratio , alveolar-arterial oxygen gradient, carbon dioxide partial arterial pressure, ventilatory efficiency index , alveolar medium diameter and ditorsion index. Surfactant treatment improved arterial oxygenation and the lung mechanics, with no differences between the study groups
40

"Avaliação dos efeitos da adição do polietilenoglicol ao surfactante pulmonar exógeno na função pulmonar, em um modelo experimental de síndrome de desconforto respiratório tipo agudo" / Lungs mechanisms and pulmonary function evaluation after polyethyleneglycol addition to the exogenous surfactant in an experimental model of ARDS

Norberto Antonio Freddi 22 September 2005 (has links)
O surfactante pulmonar é uma substância fundamental na mecânica pulmonar, com atividade biofísica e de proteção alveolar por reduzir a tensão superficial e impedir o seu colabamento.Na síndrome do desconforto respiratório tipo agudo(SDRA) ocorre uma diminuição quantitativa e disfunção qualitativa do surfactante com agravamento do quadro clínico.Estudamos, em um modelo experimental de SDRA em coelho adulto, os efeitos da adição de polietilenoglicol ao surfactante pulmonar exógeno quanto à melhora da complacência pulmonar,pressão ventilatória,índice de oxigenação,diferença alvéolo-arterial de oxigênio,gradiente alvéolo-arterial de oxigênio pressão arteial parcial de CO2, pelo índice de eficiência ventilatória,diâmetro alveolar médio e índice de distorção.A utilização do surfactante melhorou a oxigenação, e a mecânica pulmonar, sem no entanto, haver diferença entre os grupos surfactante e surfactante mais polietilenoglicol / Lung surfactant is a fundamental substance in lung mechanics, with biophysical activity to reduce alveolar surface tension and to avoid pulmonary collapse. In the acute respiratory distress syndrome (ARDS) occurs a quantitative and qualitative surfactant dysfunction with worsening of clinical status. We study, in an experimental model of ARDS in adult rabbit, the effects of polyethyeneglycol addition to the exogenous surfactant to improve the pulmonary compliance, ventilatory pressure, oxygenation index, arterial-alveolar oxygen ratio , alveolar-arterial oxygen gradient, carbon dioxide partial arterial pressure, ventilatory efficiency index , alveolar medium diameter and ditorsion index. Surfactant treatment improved arterial oxygenation and the lung mechanics, with no differences between the study groups

Page generated in 0.1052 seconds