• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1509
  • 69
  • 69
  • 69
  • 69
  • 49
  • 17
  • 11
  • 11
  • 10
  • 7
  • 5
  • 3
  • 2
  • 2
  • Tagged with
  • 1536
  • 774
  • 497
  • 457
  • 365
  • 347
  • 292
  • 240
  • 219
  • 198
  • 187
  • 185
  • 175
  • 168
  • 141
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação cinesiográfica e da satisfação de usuários de próteses totais após a utilização de dois adesivos /

Rodriguez, Larissa Santana. January 2014 (has links)
Orientador: Marco Antonio Compagnoni / Banca: João Neudenir Arioli Filho / Banca:Ana Claudia Pavarina / Banca: Claudia Helena Lovato da Silva / Banca: Pedro Cesar Garcia de Oliveira / Resumo: O objetivo deste estudo foi avaliar o efeito da utilização de dois adesivos (AS) (Ultra Corega creme- A1 e Ultra Corega pó - A2) sobre o padrão de movimentos mandibulares, movimentação da prótese total convencional (PT) superior, e o índice de satisfação dos usuários de PT com AS. Material e método: Os participantes (n=40) receberam PT novas e após o período de adaptação, foram submetidos a uma primeira avaliação, e divididos aleatoriamente em dois grupos em função dos protocolos (P): P1- utilização de A1 seguida de utilização de A2; P2 - utilização de A2 seguida de utilização de A1. As variáveis foram obtidas por meio de questionário e cinesiografia. Resultados: Houve uma intrusão semelhante entre controle, A1 e A2 (0,85 mm), porém, um maior deslocamento (0,17 mm) da PT superior após o uso de A2 (p<0,05). Não houve diferença significativa (p>0,05) para o movimento tridimensional da mandíbula após o uso de A1/A2. O conforto e retenção da PT mandibular foram influenciados pelos AS (p< 0,05). A1 e A2 não apresentam diferenças significativas em relação aos seus aspectos (p<0,05), entretanto, quando avaliada a satisfação entre eles, A1 apresentou diferenças significantes em relação a A2 (p<0,05). Conclusão: Embora a utilização de A1 ou A2 não tenha influenciado o movimento tridimensional da mandíbula, foi observado um maior deslocamento da PT superior durante a mastigação com A2. Ambos AS têm influência significativa na satisfação dos pacientes (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective ofthis studywas toevaluate the effect of using two denture adhesive (DA) (Ultra Corega cream- A1 and Ultra Corega powder - A2) on the pattern of jaw movements, maxillary complete denture (CD) movement, and satisfaction of CD with DA. Methods: Participants (n = 40) received new CD and after the adjustment period, they were submitted an initial assessment, and divided randomly into two groups according to the protocols (P): P1- use A1 followed by use A2; P2 - use A2 followed by use A1. The data were obtained through a questionnaire and kinesiography. Results: There was a similar intrusion of control, A1 and A2 (0.85 mm), but a larger displacement (0.17 mm) from the maxillary CD after use A2 (p <0.05). There was no significant difference (p> 0.05) for the three-dimensional movement of the jaw after using A1 / A2. The comfort and retention of mandibular PT were influenced by AS (p <0.05). A1 and A2 show no significant differences in relation to their aspects (p <0.05), however, when was evaluated the satisfaction between them, A1 showed significant differences from A2 (p <0.05). Conclusion: Although the use of A1 or A2 did not influence the three-dimensional movement of the jaw, a greater displacement of the maxillary CD was observed during chewing with A2. Both DA had significant influence on patient satisfaction, and A1 showed the best results. / Doutor
12

Uso e necessidade de prótese em uma população coberta pela estratégia de saúde da família

Hoisel, Roberta Silva Dias January 2016 (has links)
Submitted by Hiolanda Rêgo (hiolandarego@gmail.com) on 2016-09-08T17:59:43Z No. of bitstreams: 1 Dissertação_ODONTO_ Roberta Silva Dias Hoisel.pdf: 2183839 bytes, checksum: c70b8b2475f36c9258932ab45024c06c (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2016-10-06T13:18:41Z (GMT) No. of bitstreams: 1 Dissertação_ODONTO_ Roberta Silva Dias Hoisel.pdf: 2183839 bytes, checksum: c70b8b2475f36c9258932ab45024c06c (MD5) / Made available in DSpace on 2016-10-06T13:18:41Z (GMT). No. of bitstreams: 1 Dissertação_ODONTO_ Roberta Silva Dias Hoisel.pdf: 2183839 bytes, checksum: c70b8b2475f36c9258932ab45024c06c (MD5) / A prótese dentária é responsável pela substituição dos dentes perdidos, devolvendo o equilíbrio do sistema mastigatório e melhorando a qualidade de vida do paciente. O acesso a esse tipo de serviço no Brasil ainda é limitado. Existe uma grande demanda de indivíduos com necessidade de reabilitação protética acumulada e pouca oferta de serviços de saúde pública nessa área. O objetivo desse estudo foi verificar a associação entre uso e necessidade de prótese com variáveis sócio-econômicas, demográficas, condições de saúde geral e bucal e a percepção de necessidade de tratamento odontológico em uma população coberta pela Estratégia de Saúde da Família. Trata-se de um estudo transversal que utilizou metodologia, códigos e critérios propostos pela OMS. Os dados foram processados no programa Epi Info e foi utilizado o teste estatístico Qui-quadrado de Pearson, observando um intervalo de confiança de 95% e valor de p<0,05. Foram examinados 407 moradores de São Sebastião do Passé - BA. Os resultados mostraram que 49,6% deles necessitam de prótese no arco superior e 64,4%, no arco inferior; 20,6% utilizam prótese no arco superior e 7,1%, no arco inferior. Foi observada uma associação estatisticamente significativa entre a necessidade de prótese e a faixa etária de 15 a 34 anos (ORA: 3,23; IC: 1,38 – 7,56), a presença de gengivite (ORA: 2,02; IC: 1,20 - 3,42), a presença de cárie (ORA: 2,74; IC: 1,62 - 4,61) e a perda dentária (ORA: 5,41; IC: 2,67 - 10,96). Em relação ao uso de prótese, observou-se uma associação positiva entre o uso de prótese e a maior faixa etária (ORA: 3,86; IC: 1,73 - 8,64), e perda dentária (ORA: 5,29; IC: 2,48 – 11,30) e uma associação negativa entre o uso de prótese e participação em programas sociais (ORA: 0,46; IC: 0,26 – 0,81). Constatou-se uma importante iniquidade no acesso aos serviços odontológicos. A severidade do quadro epidemiológico mostra a necessidade de uma política pública efetiva que atenda as necessidades desta população.
13

Estomatite protética em pacientes com Diabetes mellitus: prevalência de Candida spp. e eficiência dos tratamentos com nistatina e desinfecção de próteses por micro-ondas

Sanitá, Paula Volpato [UNESP] 26 May 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-05-26Bitstream added on 2014-06-13T19:44:49Z : No. of bitstreams: 1 sanita_pv_dr_arafo.pdf: 1953204 bytes, checksum: a2f3ce08a1a45c4435513d02ab367cba (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo in vivo teve como objetivos avaliar: 1. a prevalência das diferentes espécies de Candida em pacientes diabéticos portadores de estomatite protética e compará-la àquela de pacientes não diabéticos com/sem estomatite protética; 2. a eficiência de dois tratamentos para estomatite protética em pacientes diabéticos: terapia antifúngica com nistatina e desinfecção de próteses totais por micro-ondas. Para isso, 210 pacientes usuários de prótese totais foram selecionados e distribuídos em três grupos de estudo. O grupo controle - GC foi formado por 90 pacientes não diabéticos e com mucosa oral saudável; os grupos experimentais foram formados por portadores de estomatite protética, sendo 80 pacientes não diabéticos - EPND e 40 diabéticos do tipo 2 controlados - EPD. Uma avaliação intra-oral dos pacientes dos grupos experimentais foi realizada e a aparência clínica da mucosa inflamada foi classificada de acordo com os critérios de Newton em graus I, II ou III. Coletas microbiológicas das próteses totais foram realizadas com swab estéril e plaqueadas em meio CHROMagar Candida. Em seguida, os procedimentos de identificação foram realizados: análise de microcultivo, teste de triagem fenotípica em caldo hipertônico e testes bioquímicos (ID-32C). Os resultados obtidos foram analisados por Intervalo de Confiança de Bonferroni e testes Exato de Fisher e Qui Quadrado (α=0,05). Os 40 pacientes diabéticos foram, então, submetidos ao tratamento da estomatite protética. Para isso, foram aleatoriamente distribuídos em 2 grupos (n=20): grupo NIS – tratamento com antifúngico tópico nistatina (suspensão oral - 100.000UI/mL), 4 vezes ao dia, por 14 dias; grupo MIC – tratamento por meio da irradiação das totais por micro-ondas (650W / 3 minutos), 3 vezes por semana, por 14 dias. Dois parâmetros... / The aim of this in vivo study was to evaluate: 1. the prevalence of Candida spp. in well-controlled type 2 diabetic patients and compare it to that found in non-diabetics with/without denture stomatitis; 2. the efficacy of two treatments of denture stomatitis in diabetic patients: topical nystatin and denture microwave disinfection. Two hundred and ten denture wearer patients were divided into three groups of study. The control group - CG was formed by 90 individuals without diabetes or denture stomatitis and the experimental groups were formed by patients with denture stomatitis, being 80 non-diabetics - DSND and 40 well-controlled type 2 diabetics - DSD. Mucosal characteristics of denture stomatitis patients were classified in types I, II, and III, according to Newton’s criteria. Mycological samples were taken from the dentures and cultured in CHROMagar′s plates. Candida spp. were identified by micro-cultivation, hypertonic Sabouraud broth, and bioMérieux ID32C assays. Results were analyzed by means of Bonferroni corrected confidence interval, Fisher’s exact test, and Chi-square analysis of several proportions (α=0.05). The 40 diabetic patients were divided into two groups (n=20) and submitted to two treatments for denture stomatitis: NYS group – patients were treated with topical nystatin, 4 times a day, for 14 days; MW group – patients had their dentures microwaved (650W / 3 minutes), 3 times per week, for 14 days. Mycological samples were taken from the palates and the tissue surface of the dentures for quantification and identification of Candida spp. and standardized photographs of the palates were taken for the clinical analysis. Microbiological and clinical evaluations were repeated at baseline... (Complete abstract click electronic access below)
14

Influência da adição de reforço e ciclagem mecânica na resistência ao impacto de resinas para base e para reembasamento imediato /

Perez, Luciano Elias da Cruz. January 2009 (has links)
Orientador: Ana Lúcia Machado / Coorientador: Sebastião Vicente Canevarolo Junior / Banca: Maria da Gloria Chiarello de Mattos / Banca: Sicknan Soares Rocha / Banca: Marco Antonio Compagnoni / Banca: Ana Claúdia Pavarina / Resumo: Este estudo avaliou o efeito da adição de reforço e ciclagem mecânica sobre a resistência ao impacto, por meio dos testes Charpy (C) e queda livre de dardo (QL), para resinas de base e para reembasamento imediato. Para o teste C, corpos-de-prova (60x6x2 mm) foram confeccionados com as resinas Lucitone 550 (L) e Vipi Wave (V) e reembasados (2 mm) com o mesmo material (L/L ou V/V) ou com as resinas para reembasamento imediato Tokuyama Rebase II (T) e Ufi Gel Hard (U). Corpos-de-prova puros de L, V, T e U (60x6x4 mm) também foram confeccionados para se determinar a resistência ao impacto dessas resinas. Para a avaliação da adição de reforço, foi adicionado ao pó das resinas reembasadoras 5%, em massa, do reforço de floco de vidro "glass flake" (UR, TR, L/UR, L/TR, V/UR, V/TR). 320 corpos-de-prova foram confeccionados, sendo 20 para cada condição experimental. Metade desses foi submetida à ciclagem mecânica (10.000 ciclos) com freqüência de 5 Hz (LC, VC, TC, UC, URC, TRC, L/URC, L/TRC, V/URC, V/TRC). Um entalhe, em forma de V foi realizado na largura, na superfície correspondente ao material reembasador, com profundidade de 0,8 mm, permanecendo 3,2 mm de material intacto. O teste foi realizado com pêndulo de 0,5 J e distância de 50 mm entre os suportes. Os resultados (kJ/ m2) foram analisados utilizando-se ANOVA e teste de Dunnet C (α = .05). Não houve diferenças estatisticamente significantes entre as médias de resistência ao impacto das condições L, L/L, V, V/V, LC, L/LC, VC e V/VC. As condições experimentais relativas às resinas autopolimerizáveis U, T, UC, TC, UR, TR e TRC foram estatisticamente iguais entre si. Além disso, URC também foi estatisticamente igual a U, T, UC, TC, TR e TRC, porém, maior do que UR. Não houve diferença significativa (P>.05) entre as médias de resistência ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of the addition reinforcement and cyclic loading on the resistance to impact of Charpy tests (C) and free falling-dart (FD) for the denture base resins and reline materials. To test the C, bars (60x6x2 mm) were prepared with the resins Lucitone 550 (L) and Vipi Wave (V) and relined (2 mm) with the same material (L / L or V / V) or with relining resins Tokuyama Rebase II (T) and UFI Gel Hard (U). Specimens pure of L, V, T and U (60x6x4 mm) were also made to determine the impact resistance of these resins. For the evaluation of the addition of reinforcement, was added to the powder of the relining resins 5% by weight of the glass flake "glass flake" (UR, TR, L / UR, L / TR, V / UR, V / TR). 320 specimens were made, 20 for each experimental condition. Half of these were subjected to cyclic loading (10,000 cycles) with a frequency of 5 Hz (LC, VC, TC, UC, URC, TRC, L / URC, L / TRC, V / URC, V / TRC). A notch in the form of V was carried out in width, the area corresponding to the relining material with depth of 0.8 mm, 3.2 mm of material remained intact. The test was conducted with pendulum of 0.5 J and 50 mm distance between the supports. The results (kJ/ m2) were analyzed using the ANOVA and Dunnet C test (α = .05). No significant differences were noted among the mean impact values of L, L / L, V, V / V, LC, L / LC, VC and V / VC. The experimental conditions for relining resins U, T, UC, TC, UR, TR and TRC were statistically equal between themselves. In addition, URC was statistically equal to U, T, UC, TC, TR and TRC, however, higher than UR. No significant differences were noted (P> .05) mong the mean impact values of L/ U, V/ U, L/ UC, V/ UC, L/URC and V/ URC. These conditions had values of resistance to impact significantly lower than those of the resin tested pure L and T (P <.05). There was... (Complete abstract click electronic access below) / Doutor
15

Influência da utilização de um adesivo para prótese na satisfação e nos parâmetros cinesiográficos de usuários de próteses totais /

Mendoza Marin, Danny Omar. January 2013 (has links)
Orientador: Marco Antonio Compagnoni / Banca: Ana Carolina Pero / Banca: Claudia Helena Lovato da Silva / Resumo: Objetivo: O objetivo deste estudo foi avaliar o efeito da utilização de um adesivo para prótese na satisfação e nos parâmetros cinesiográficos em usuários de próteses totais por meio de um estudo "cross-over". Material e Métodos: Cinquenta pacientes desdentados receberam novas próteses totais bimaxilares. Após um período de adaptação, os participantes incluídos no estudo receberam uma sequência de tratamento: protocolo 1- utilização do adesivo para prótese durante os primeiros 15 dias, seguida por não utilização do adesivo os próximos 15 dias; protocolo 2- não utilização do adesivo durante os primeiros 15 dias; seguida por utilização do adesivo os próximos 15 dias. Os resultados foram avaliados após 15 dias de cada sequência de tratamento. Um questionário para avaliar a satisfação dos pacientes e um cinesiógrafo para registrar os movimentos mandibulares e o padrão de movimento da prótese total maxilar durante mastigação foram utilizados. O teste de "Wilcoxon" (α=0,05) e o "t-test" de student para amostras pareadas (α=0,05) foram utilizados para comparar o grau de satisfação dos pacientes e os dados cinesiográficos, respectivamente. Resultados: O adesivo para prótese melhorou significativamente a satisfação geral dos participantes (p<0,001). Os registros cinesiográficos mostraram um aumento significativo (1,7mm) no movimento mandibular vertical (p<0,001) e uma menor intrusão (0,3mm) da prótese total superior (p=0,002) durante a mastigação após o uso de adesivo. Conclusão: O uso de adesivo para prótese melhorou a satisfação dos usuários de próteses totais e gerou um aumento no movimento mandibular vertical e uma menor intrusão da prótese total maxilar durante a mastigação / Abstract: Objectives: The objective of this study was to evaluate the effect of a denture adhesive (DA) on patient satisfaction and kinesiographic parameters of complete denture wearers by a cross-over study. Material and Methods: Fifty edentulous patients received one set of new complete dentures. After an adaptation period, the participants were enrolled in the trial and randomized to receive a sequence of treatment: protocol 1- DA use during the first 15 days, followed by the no use of DA over the next 15 days; protocol 2- no use of DA during the first 15 days, followed by use of DA over the next 15 days. Outcomes were assessed after 15 days of each sequence of treatment. A questionnaire was used to evaluate patients' satisfaction and a kinesiograph instrument was used to record mandible movements and pattern of maxillary complete denture movement during chewing. Wilcoxon test (α=.05) and a paired sample t-test (α=.05) were used to compare satisfaction levels and kinesiographic data, respectively. Results: The use of DA improved the overall patients' satisfaction (p<.001). Kinesiographic recordings revealed a significant increase (1.7mm) on vertical mandible movements (p<0,001) during chewing and a lower (.3mm) vertical intrusion of the maxillary complete denture (p=0,002) during chewing after use of DA. Conclusion: The use of a DA in complete dentures wearers improved the patients' satisfaction and change mandible movements, with increases in vertical mandible movements during chewing and lower intrusion of maxillary complete denture / Mestre
16

Influência da retificação de cilindros fundidos em liga não-nobre na passividade de próteses parciais fixas implanto-suportadas

Triches, Diego Fernandes January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:25Z (GMT). No. of bitstreams: 2 000400559-0.pdf: 7718484 bytes, checksum: 719fc2b40ca8e1122762ae277126d1c6 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The passivity of the prosthetic frameworks over implants is directly related to the longevity of this kind of treatment and own implants. As the framework manufacturing technique may influence the passivity degree, this paper aimed to study the manual adjustment influence in the passivity degree of frameworks that simulate a fixed partial denture from three elements over two implants. Therefore, two external hexagon implants of 3. 75 mm x 10mm were used, with their intermediaries abutments, set on a steel base, forming the master model. From this, ten cobalt-chromium alloy frameworks were manufactured through the casting by induction technique. Three groups were created: Group 1 using pre-machined cylinders for manufacturing five frameworks; Group 2 with plastic cylinders for casting five frameworks; Group 3 formed by Group 2 frameworks after the manual adjustment of the prosthetic cylinders base. For passivity evaluation, strain-gauges stucked in the cervical and occlusal regions from the framework pontics were used. The measurement was performed at the tightness of the prosthetic second screw with a 10 Ncm torque. The One Way ANOVA (α = 0,05) statistical test was used. The groups averages were 39. 16 mV / V (DP 24. 74 mV / V) in Group 1, 43. 76 mV / V (DP 21. 13 mV / V) in Group 2 and 43. 64 mV / V (DP 23. 38 mV / V) in Group 3. There was no statistically significant difference between groups (p = 0,938). Therefore, considering this study limitations, it is suggested that the manual adjustment of prosthetic cylinders did not improve the passivity degree of frameworks under study. However, the groups that used plastic cylinders for melt had similar passivity degree to the group that used pre-machined cylinders. / A passividade das infra-estruturas de próteses sobre implantes está diretamente relacionada com a longevidade deste tipo de tratamento protético e dos próprios implantes. Como a técnica de fabricação das infra-estruturas pode influenciar o seu grau de passividade, este trabalho objetivou estudar a influência da retificação manual no grau de passividade de infra-estruturas que simulam uma prótese parcial fixa de três elementos sobre dois implantes. Para tanto, foram utilizados dois implantes de hexágono externo de 3,75mm x 10mm, com seus respectivos pilares intermediários, fixados numa base de aço, formando o modelo-mestre. A partir disto, foram fabricadas dez infra-estruturas em liga de cobalto-cromo através da técnica de fundição por indução. Foram criados três grupos: Grupo 1 utilizando cilindros pré-usinados para a fabricação de cinco infra-estruturas; Grupo 2 cinco infra-estruturas fundidas com cilindros de plástico calcináveis; Grupo 3 formado pelas infra-estruturas do Grupo 2 após a retificação manual da base dos cilindros protéticos. Para avaliação da passividade foram utilizados extensômetros colados na região oclusal e cervical do pôntico das infra-estruturas. A medição foi realizada no momento do aperto do segundo parafuso protético com torque de 10 Ncm. Foi utilizado o teste estatístico ANOVA (α = 0,05). As médias dos grupos foram de 39,16 mV/V (DP 24,74 mV/V) no Grupo 1, 43,76 mV/V (DP 21,13 mV/V) no Grupo 2 e 43,64 mV/V (DP 23,38 mV/V) no Grupo 3. Não foi encontrada diferença estatisticamente significante entre os grupos (p = 0,938).Portanto, considerando-se as limitações deste trabalho, sugere-se que a retificação manual dos cilindros protéticos não melhorou o grau de passividade das infra-estruturas em estudo, porém, os grupos que utilizaram cilindros calcináveis tiveram o mesmo grau de passividade do grupo com cilindros pré-usinados.
17

Programação de articuladores em protese total : comparação entre metodos

Cardoso, Luiz Antonio Morais, 1963- 08 January 1998 (has links)
Orientador: Jose Roberto Lovadino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T03:09:08Z (GMT). No. of bitstreams: 1 Cardoso_LuizAntonioMorais_D.pdf: 1865461 bytes, checksum: eae73caa17a06a50397f7619a4458242 (MD5) Previous issue date: 1997 / Resumo: Neste estudo foram considerados dois valores de grande interesse protético: inclinação da trajetória condílica ântero-posterior (guia condilar) e ângulo de Bennett. Essas duas grandezas serviram para referência de comparação entre dois métodos de programação de articuladores empregados na confecção de próteses totais. O primeiro método foi o chamado desgaste de Paterson que utiliza arcos de orientação com mistura abrasiva, que atritados pelo próprio paciente, conforma individualmente cada conjunto, que por sua vez, serve para programar o articulador. O segundo método, chamado técnica de Nóbilo, emprega o registro intra oral modificado, permitindo que as posições de interesse para a programação do articulador sejam definidas e tranferidas com o auxílio de moldagens vestibulares das posturas. Os métodos foram aplicados em 27 pacientes desdentados totais. Para a inclinação da guia condilar, o método de Paterson obeve média de 26,10 graus e o de Nóbilo 30,87 graus. Para o ângulo de Bennnett, o método de Paterson conseguiu 13,14 graus e o de Nóbilo 16,34 graus. Para ambos os valores protéticos a análise de variância considerou haver diferença entre os resultados obtidos pelos métodos. No entanto, em relação ao lado das articulações, nenhum método detectou diferença / Abstract: In this study were considerate two values with big prosthetic interest: anterior-posterior trajectory inclination of condyle and Bennett angle. These two greatness were useful for reference to compare two methods of articulators programation employed in dentures construclion. The first method was called Paterson abrasion that wich utilize orientation arcs with abrasive misture, frictioned for the own patient conform individualy each conjunct; that which in this way serve to articulator shedule. The second method, called Nobilo's technique used the intra-oral register modifyed, allowing to be defined to the articulator sheduling to be able to be defined and transfered with the vestibular posture impression. The methods were apliyed in 27 patients. To the inclination of condylar guide, the Paterson method got 26.10 grades and Nobilo's one got 30.87 grades. To the Bennett angle, Paterson method got 13.14 grades and Nobilo's one got 16.34 grades. To both prosthetic values, the variance analysis considered to the difference between the results got for the two methods. Never the lless in articulations side relation, no one method detected differences / Doutorado / Protese / Doutor em Clínica Odontológica
18

Efeito de um limpador de protese na concentração de compostos sulfurados volateis e na microbiota bucal de pacientes idosos institucionalizados portadores de proteses totais

Oliveira, Viviane Maia Barreto de 11 November 2003 (has links)
Orientadores: Altair A. Del Bel Cury, Pedro Luiz Rosalen / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T18:53:40Z (GMT). No. of bitstreams: 1 Oliveira_VivianeMaiaBarretode_D.pdf: 3110818 bytes, checksum: 40e9aa33bfe2bfa6fd45609e4b286025 (MD5) Previous issue date: 2003 / Resumo: O objetivo deste estudo foi verificar a eficácia do limpador de prótese Polident 5 minutes@ (Block and Drug Corp.) quanto à redução da concentração de Compostos Sulfurados Voláteis (CSV), por meio do Halimeter@ (Interscan Corp.) e a ação bactericida pela cultura microbiana em ágar sangue e MacConkey, além de avaliar a correlação entre a habilidade em higienizar as próteses (HA) e o índice de biofilme (IB) sobre as mesmas. Foram selecionados 19 voluntários, com idades entre de 62 a 86 anos, portadores de pelo menos prótese total superior. As análises foram realizadas em duas fases (F). FI: avaliação m e verificação HA, determinação da concentração de CSV e coleta do biofilme das próteses antigas, nos tempos To (sem uso do limpador), TI, T2eT3 (uso contínuo do limpador por 7, 14 e 28 dias); FII: novas próteses foram instaladas, a concentração de CSV foi determinada e o biofilme foi coletado após 30, 60 e 90 dias de uso contínuo do limpador (Tu, T2.2, T3.3). Os resultados para a concentração de CSV apresentaram diferença estatística entre os períodos Toe TI, e Tu e T 2.2, verificada pelo 64, 67A; T3.3: 53,67B. Na avaliação de microrganismos crescidos em aerobiose os resultados não mostraram diferença estatística significativa na FI e na F 11 houve diferença estatística entre todos os tempos, verificada pelo Teste T pareado (p<0,05): To: 3,34a; TI: 2,22a; T2: 2,92a; T3: 4,24a; Tu: O, 14c; T2.2: 1,12B; T33: 2,74B. Concluiu-se que houve uma correlação positiva entre a HA e m, que o limpador não foi eficaz na remoção do biofilme aderido à prótese antiga e não impediu a formação de biofilme nas novas próteses, assim como não reduziu os níveis de CSV dos pacientes / Abstract: The purpose of this study was to determine the effectiveness of the Polident 5 minutes@ (Block and Drug Corp.) denture cleanser in reducing V olatile Sulphur Compounds (VSC) concentration, estimated by Halimeter@ (Interscan Corp.) and the bactericide action by Blood Ágar and MacConkey culture, besides evaluating the correlation among the denture cleaning dexterity (DC) and the biofilm index (BI). 19 volunteers were selected with age range 62 to 86 years, wearing at least the upper denture. The analysis was conducted in two phases (P): PI: BI evaluation, volunteers DC, determination of VSC concentration and the biofilm was collected ITom the old denture before the use of the treatment protocol (To), and after 7, 14 and 28 days of continuous cleanser use (TI, T2 and T3); Pu: new denture was installed, VSC concentration was determinated and biofilm was collected at 30, 60 and 90 days with daily use ofthe denture cleanser (Tu, T2.2, T3.3). The VSC concentration results showed statistical difference between To and results did not show statistical difference at Phase I and, at Phase 11, there was statistical difference between alI the times, by paired-T test (p<0.05): To: 3,343; TI: 2,223; T2: 2,923; denture cleanser was not efficient to remove the old denture biofilm, did not prevent the new denture biofilm and did not reduce patients VCS levels / Doutorado / Protese Dental / Doutor em Clínica Odontológica
19

Dimensão vertical de oclusão em desdentados totais obtida pelos métodos de Tamaki de Beresin & Schiesser: estudo comparativo.

De Jesus Tavarez, Rudys Rodolfo 08 August 1997 (has links)
A dimensão vertical de oclusão obtida pelos métodos de Tamaki e de Beresin & Schiesser; e a altura das próteses que os pacientes utilizavam, foram determinadas em uma amostra de 30 pacientes desdentados totais superior e inferior, com idade entre 38 e 77 anos; apresentando prótesis totais duplas totais em uso por um período mínimo de cinco anos, rebordos alveolares clinicamente favoráveis, ausência de sintomas de desordens temporomandibulares, com movimentos mandibulares normais. Os valores obtidos em cada um dos métodos testados foram comparados e relacionados com as alturas encontradas nas próteses que os pacientes utilizavam. Os resultados obtidos permitiram concluir que: 1) houve diferença estatisticamente significante em nível de 0,01 %, quando se compararam os valores obtidos pelos dois métodos; 2) quando comparados os métodos de Tamaki e Beresin & Schiesser em relação as alturas das próteses utilizadas, pode-se observar uma diferença média positiva de 3,02mm e 4,40mm respectivamente. / The vertical dimension of oclussion obtained by Tamaki’s and Beresin & Schiesser’s methods and the height of the complete dentures used by the patiens were obtained in a 30 edentulous persons sample with ages ranging from 38 to 77 years old, that had been wearing superior and inferior complete dentures for at least 5 years, in hose residual ridges were clinically favorable, and showing normal mandibular movements and absence of temporomandibular disordens. The purpose of this study was comparing the values obteined in each of the tested methods and correlating them with the heights taken of the dentures usedby the patients. As so checking the correspondence grade existing in each one. The results showed that: 1) There was statistically significant difference when comparing the values obteined in the two methods; being that there was a great correlation between these values to the leve of 0,01 %; 2) When comparing Tamaki’s and Beresin & Schiesser’s methods in relation to the heights of dentures used, a positiver medium difference could be observed, of 3.02mm and 4.40mm respectively.
20

Efeito de cargas cíclicas na resistência à fratura de dentes tratados endodonticamente reconstruídos com pinos pré-fabricados estéticos e metálicos restaurados com coroas de porcelana pura.

Xible, Anuar Antonio 27 October 2004 (has links)
Foram avaliados, in vitro, o efeito da aplicação de carga cíclica na resistência à fratura, a resistência à fratura, modo de fratura e associação entre as dimensões MD e VL com resistência à fratura de dentes reconstruídos com sistemas de pinos pré-fabricados metálicos convencionais e estéticos, restaurados com coroas de porcelana pura, submetidos à fadiga térmica e mecânica através de teste à compressão com carga estática. Sessenta caninos íntegros tiveram suas coroas amputadas 1,5mm acima da junção cementoesmalte e preparados para coroa de porcelana pura. Os dente foram distribuídos em 6 grupos de 10 dentes. Os grupos 1 e 2 foram restaurados com pinos pré-fabricados de cerâmica de zircônia Cosmopost (Ivoclar-Vivadent) e núcleo de preenchimento em cerâmica vítrea termo-injetada IPS Empress Cosmo Post (Ivoclar-Vivadent). Os grupos 3 e 4 foram restaurados com pinos pré-fabricados de resina composta reforçada por fibra de vidro FibreKor (Jeneric Pentron) e os grupos 5 e 6 com pinos de titânio AZthec Anchor Titanium (Dentatus). Nos grupos 3, 4, 5 e 6 foi usada resina composta reforçada com fibra de vidro Build It FR Fiber Reinforced Core (Jeneric Pentron) como material para núcleo de preenchimento; os dentes foram restaurados com coroas totais IPS Empress 2 (Ivoclar-Vivadent); tanto os pinos quanto as coroas de porcelana foram cimentados com o sistema resinoso de polimerização dupla Cement It / Bond It Primer A + B (Jeneric Pentron). Os espécimes foram submetidos à ciclagem térmica por 300X, em temperaturas de 5°C e 55°C e incluídos em resina acrílica em blocos de alumínio. Os grupos 2, 4 e 6 foram submetidos à uma carga cíclica de 250N por 500,000X, a uma freqüência de 1,7Hz. Os 6 grupos foram submetidos à carga estática em uma máquina de testes universal até falha dos sistemas. Após a carga estática os espécimes foram avaliados quanto ao modo de fratura e classificados em 02 tipos: Supra-crestal (SC) - quando a fratura se localizou até 1mm abaixo da linha de inclusão dos espécimes na resina acrílica ou Infra-crestal (IC) - quando a linha de fratura se localizou 1,1mm ou mais, abaixo da linha de inclusão dos espécimes na resina acrílica. Os dados foram analisados estatisticamente com os testes ANOVA a 2 critérios, Tukey, Correlação de Pearson, Q Quadrado (&#967;2) e Exato de Fischer. Na análise da resistência à fratura, o valor do grupo 1 (1165,5±211,95N) foi maior do que o grupo 2 (886,50±170,62N); o do grupo 3 (1041,50±231,20N) foi maior do que o do grupo 4 (762,20±113,63N) e o do grupo 5 (768,90±72,95N) foi maior do que o do grupo 6 (985,40±99,89N) (p<0.05). O valor do grupo de pinos de zircônia foi significantemente maior do que os grupos de pinos de resina composta reforçados por fibras de vidro e titânio (p<0.05), que foram iguais entre si (p=0,146) independente da aplicação da carga cíclica (p<0,05). A carga cíclica diminuiu significantemente a resistência dos dentes restaurados (p<0,05). Houve fraca, porém significante relação entre a dimensão MD e resistência à fratura dos espécimes (r=0,260 e p=0,044). Na análise do modo de fratura, o grupo 1 apresentou 30% de fraturas SC e 70% IC; o grupo 2 apresentou 60% de fraturas SC e 40% IC; o grupo 3 apresentou 60% de fraturas SC e 40% IC; no grupo 4 houve 90% de fraturas SC e 10% de IC; no grupo 5 houve 40% de fraturas SC e 60% de IC enquanto no grupo 6, 50% de fraturas SC e 50% IC. Não houve correlação entre o tipo de pino e modo de fratura (&#967;2=0,484 e p=0,885), independente do uso de carga cíclica. Em conclusão, os dentes restaurados com pinos de zircônia e núcleos de preenchimento de porcelana vítrea apresentaram os melhores valores de resistência à fratura, independente da aplicação de carga cíclica, entre os grupos testados; o tratamento com carga cíclica reduziu significantemente a resistência em todos os grupos testados. Não houve diferença de resistência à fratura entre os grupos restaurados com resina composta reforçado por fibra de vidro e titânio, independente da aplicação da carga cíclica. Não houve correlação entre o tipo de pino e o modo de fratura, e, quanto maior a dimensão MD dos espécimes, maior a força necessária para levá-los à fratura. / This study compared the effect of cyclic load, survival rate, residual strength, the mode of fracture and relationship between MD and BL dimensions and strength of endodontically treated teeth restored with three esthetic post systems subjected to thermal and mechanical cyclic load. Sixty canines were selected for the study. They were endodontically treated with guta percha points and calcium hydroxide cement (Sealapex – Kerr), decoronated 1.5mm above the cementum enamel junction and prepared for metal free ceramic crowns (1.0mm in BL and 0.8mm in MD direction and rounded shoulder), leaving a remaining dentin amount of 1.5mm high as ferrule effect. After BL, MD dimensions were obtained, they were distributed in 6 groups according to the stratified method. Groups 1 and 2 were restored with 1.7mm in diameter zirconia posts (Cosmopost – Ivoclar Vivadent) and heat pressed glass-ceramic cores (IPS Empress Cosmo – Ivoclar Vivadent); groups 3 and 4 were restored with 1.5mm in diameter fiber reinforced composite posts (FibreKor – Jeneric Pentron) and group 5 and 6 were restored with 1.65mm in diameter titanium posts (AZthec Anchor – Dentatus). Direct resin composite (Build It FR – Jeneric Pentron) were used as cores for the 4 latest groups. All specimens were restored with all ceramic crowns (Empress 2 – Ivoclar). In all groups, a resin cement/adhesive system (Cement It/Bond It Primer A+B) was used to lute the posts to root canals and metal free porcelain crowns to the teeth. Twenty-four hours after cementing the crowns, the specimens were subjected to 300x thermal cycles with temperature ranging from 5°C to 55°C with 30sec of dwell time. Specimens were then embedded in resin acrylic, mounted in aluminum blocks. Groups 2, 4 and 6 were subjected 500.000x to a mechanical load of 250N in a frequency of 1.7Hz. All specimens were set in an Instron machine and subjected to static load until failure. Data were recorded and analyzed using Two-way ANOVA,Tukey, Pearson Correlation, Chi Square and Exact Fischer tests. Group 1 (1165.7±210.95N) was higher than group 2 (886.50±170.62N); group 3 (1041.50±231.20N) was higher than group 4 (762.20±113.63N) and group 5 (985.40±99.89N) was higher than group 6 (768,90±72.95 N). Zirconia group values were higher than all the other groups (p<0.05); there was no statistically difference between fiber reinforced composite and titanium group even after the cyclic loading (p=0.146); cyclic loading reduced significantly the fracture strength of all groups (p<0.00); there was no correlation between type of posts and decrease in fracture strength (p=0.778); there were a weak but significant correlation between MD specimens dimension and load to failure (r=0.260 e p=0.044); there was no correlation between the mode of failure and type of posts (&#967;2=4.484 e p=0.885). It was concluded that: 1-Teeth restored with zirconia posts and glass-ceramic cores showed the highest strength to fracture, regardless the cyclic loading application; 2- The cyclic loading treatment lowered the fracture strength of all groups tested; 3- Fiber reinforced composite posts group values were not significantly different from titanium posts regardless the cyclic loading application; 4- Larger MD dimension may favor an increase in the fracture strength of teeth restored with pre-fabricated post systems.

Page generated in 0.4272 seconds