• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1509
  • 69
  • 69
  • 69
  • 69
  • 49
  • 17
  • 11
  • 11
  • 10
  • 7
  • 5
  • 3
  • 2
  • 2
  • Tagged with
  • 1536
  • 774
  • 497
  • 457
  • 365
  • 347
  • 292
  • 240
  • 219
  • 198
  • 187
  • 185
  • 175
  • 168
  • 141
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Recuperação da dimensão vertical fisiologica da face nos desdentados totais. Utilização de proteses totais com pistas deslizantes nos quadrantes oclusais

Trindade, Marilene O 22 July 2018 (has links)
Orientador: Krunislave Antonio Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-22T13:02:38Z (GMT). No. of bitstreams: 1 Trindade_MarileneO_M.pdf: 2325421 bytes, checksum: 3af4371747e27259c6040357a7b36652 (MD5) Previous issue date: 1993 / Resumo: Este trabalho foi realizado com a finalidade de acompanhar o processo de recuperação da dimensão vertical da face de desdentados, reorganização das fibras musculares responsáveis pela posição postural de repouso e reposicionamento mandibular no plano sagital. Foram selecionados 10 pacientes adultos com suas dimensões verticais do segmento inferior da face alterados, para menos, sem sintomatologia dolorosa no aparelho estomatognático e desdentados há pelo menos 10 anos ...Observação: O resumo, na íntegra poderá ser visualizado no texto completo da tese digital / Abstract: This work was done in order to accompany the vertical dimension's recovery of the edentulous faces, reorganization of the muscular fibre for the rest position and for the mandibular repositioning in sagital plain. Ten adult patients were selected with their vertical dimension of the face inferior segment altered to less without painful symptoms in the stomagnatic set and edentulous for at least ten years ...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Fisiologia e Biofisica do Sistema Estomatognatico / Mestre em Ciências
42

Fechamento da parede abdominal com afastamento parcial das bordas da aponeurose utilizando sobreposição com telas de vicryl ou marlex em ratos

Mazzini, Decio Luiz Silva 05 June 1997 (has links)
Orientador: Mario Mantovani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-23T00:39:10Z (GMT). No. of bitstreams: 1 Mazzini_DecioLuizSilva_M.pdf: 3640453 bytes, checksum: 57b05fd14bf270a2f91cfd357306726b (MD5) Previous issue date: 1997 / Resumo: O presente experimento tem por finalidade estudar comparativamente o efeito da aplicação de telas absorvíveis e inabsorvíveis, como reforço no fechamento de incisões medianas abdominais em ratos, na situação de aproximação parcial das bordas das aponeuroses. Para isto, foram estudados 45 ratos machos da raça Wystar, divididos em três grupos, nos quais se procedeu da seguinte maneira: Grupo "controle": incisão mediana abdominal atingindo a cavidade peritoneal, seguida por fechamento apenas da pele Grupo "vicryl": incisão mediana abdominal atingindo a cavidade peritoneal, seguida por reforço com tela de vicryl, sobreposta em forma de ponte sobre a aponeurose, mantendo os lábios da aponeurose distantes entre si por 1,0 cm. Grupo "marlex": procedimento idêntico ao grupo "vicryl", substituindo-se a tela de vicryl por marlex. Após um ano os animais foram sacrificados e submetidos à avaliação macroscópica quanto à presença de hérnias e aderências às telas; aferição da resistência tênsil da cicatriz cirúrgica através de tração por dinamômetro e estudo histológico dos seguintes fenômenos da cicatrização: reação inflamatória crônica, inflamação granulomatosa tipo corpo estranho, tecido de granulação, hiperplasia fibroblástica e fibrose. Apenas os animais do grupo "controle" desenvolveram hérnias ao final do experimento. Não houve formação de aderências intestinais significativas em nenhum dos grupos estudados. A resistência tênsil foi significativamente maiOr nos anImaIs em que se aplicaram telas para reforço. A reação inflamatória crônica e a inflamação granulomatosa tipo corpo estranho foram muito mais intensas no grupo em que se utilizou marlex, que nos demais grupos. Quanto ao tecido de granulação e hiperplasia fibroblástica, estavam ausentes em todos os grupos. A fibrose foi mais intensa nos grupos em que as telas foram empregadas. Conclui-se que a utilização de telas nesta situação evita o desenvolvimento de hérnias, no prazo de seguimento de um ano, porque confere maior resistência tênsil à parede abdominal e a aplicação de tela de vi~ryl, além de proporcionar esta resistência, ainda o faz com menor reação inflamatória crônica e granulomatosa tipo corpo estranho / Abstract: The present experiment has as a purpose to study comparatively the efTect of absorbable and unabsorbable mesh, as a reinforcement in the closing of the median abdominal incisions in rats, in the situation of the partial approximation of the borders of the aponeurosis. For this, 45 male rats ofthe Wystar breed were studied, divided into three groups, in which the procedure was in the folIowing manner. "Control group": median abdominal incision reaching the peritoneal cavity folIowed only by the closing of the skin and subcutaneous celular. "Vicryl group": median abdominal incision reaching the peritoneal cavity folIowed by a reinforcement with vicryl mesh, overlaid in the form of a bridge over the aponeurosis, maintaining the lips ofthe aponeurosis distant amid themselves by 1,0 cm. "Marlex group": the procedure is identical to the "vicryl" group, substituting the vicryl mesh by the marlex mesh. After one year the animaIs were sacrificed and submitted to a microscopic valuation as to the presence of hemias and adherences to the meshes; checking the tension resistance of the surgical scar through the traction by dinamometer and histological study of the folIowing phenomenons of the cicatrization; chronical inflamatory reaction, foreign body type granulomatosis inflamation, granulation tissue, fibroblastic hyperplasia and fibrosis. Only animaIs of the "control group" developed hemias in the final experimetlt. There was no significative formation of intestinal adherences in any of the group studied. The tension resistence was signifiçantly greater in the animaIs in which meshes were applied for reinforcement. The chronical inflamatory reaction and the foreing body type granulomatosis inflamation were much more intense in the group in which marlex was used, than in the other groups. As to the granulation tissue and fibroblastic hyperplasia,they were absent in alI the groups. The fibrosis was more intense in the group in which the meshes were employed. Its is concluded that the utilization of meshes in this situation avoids the hemia development in the follow up of one year, because it granted a greater tensile resistance of the abdominal wall the employment of the vicryl mesh, besides offering this resistance, still makes it with less chronical inflamatory reaction and foreign body type granulomatosis inflamation / Mestrado / Mestre em Cirurgia
43

Analise do comportamento do som articular em individuos com alterações funcionais do sistema estomatognatico, tratados com aparelhos oclusais planos

Oliveira, Isabel Toscanelli de 09 December 2000 (has links)
Orientadores : Wilkens Aurelio Buarque e Silva, Fausto Berzin / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T06:46:55Z (GMT). No. of bitstreams: 1 Oliveira_IsabelToscanellide_M.pdf: 3538607 bytes, checksum: 96c8296e27d54b7c085b5bdd45125e6f (MD5) Previous issue date: 2000 / Resumo: As alterações funcionais do sistema estomatognático têm sido objeto de observações e estudo em diversas áreas da odontologia. Os sons emitidos pelas articulações temporomandibulares durante a função mastigatória, constituem-se em um dos sinais mais prevalentes deste quadro patológico. O objetivo desta pesquisa foi estudar o comportamento do som articular, no que concerne a sua intensidade e reprodutibilidade, através de avaliações eletrosonográficas, ausculta e escala visual analógica, em pacientes portadores de alterações funcionais do sistema estomatognático, tratados com aparelhos de cobertura oclusal plana. Para a realização da pesquisa, foram selecionados dez pacientes, os quais foram submetidos às avaliações previstas na ficha clínica do CETASE. Todos os voluntários utilizaram aparelhos de cobertura oclusal plana, por um período de 240 dias, onde foi observada a remissão da sintomatologia inicial e, o comportamento dos sons articulares sob três aspectos: o relato clínico do paciente, através de uma escala analógica visual; a ausculta e a eletrosonografia computadorizada. Em função da metodologia proposta e dos resultados obtidos, concluímos que: houve uma redução na intensidade e reprodutibilidade dos sons articulares em todos os parâmetros analisados; as avaliações eletrosonográficas computadorizadas, permitiram a análise dos ruídos articulares em níveis abaixo dos limites do ouvido humano e que; a terapia com aparelhos de cobertura oclusal plana, foi efetiva para a remissão da sintomatologia apresentada inicialmente pelos pacientes / Abstract: The Functional Alterations of Stomathognatic System had been the aim of study in various areas in dentistry. The articular sounds emitted during the masticatory function, are important indications of this pathology. The aim of this research, were to study the articular noise comportment in intensity and reproducibility, through electrosonographic evaluations, auscultation and clinical report, in patients with temporomandibular disorders, treated with plain occlusal splints. Ten patients were selected and submitted to the evaluations includes in CET ASE clinical fickle. Ali of them used plain occlusal splints for a period of 240 days, where were observed the symptomatology decrease and the comportment of the articular noise in three aspects: the clinical report, through an analogical visual scales, auscultation and computerized electrosonographic evaluations. The obtained results permitted to conclude that: there were a decrease in intensity and reproducibility of the articular noise in ali of the parameters analyzed; the computerized electrosonographic evaluations permitted an analyze of the articular sounds in levels down of the limits of the human ear and that, the plain occlusal splints therapy were effective to the remission of the symptomatology presented initially for the patients / Mestrado / Protese Dental / Mestre em Clínica Odontológica
44

Analise do assentamento passivo de infra-estruturas em titanio e liga de paladio-prata, fundidas em monobloco e submetidas a soldagem a laser

Sousa, Samira Albuquerque de 03 September 2001 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T21:28:19Z (GMT). No. of bitstreams: 1 Sousa_SamiraAlbuquerquede_M.pdf: 13576811 bytes, checksum: 7e60e73bfad677f2750d67484e369966 (MD5) Previous issue date: 2001 / Resumo: Este estudo se propôs avaliar o assentamento passivo de infra estruturas fundidas em titânio e liga de paládio-prata, confeccionadas pela técnica monobloco e soldagem à laser. A partir de uma matriz metálica com cinco implantes (3,75 X 13mm), obteve-se um modelo mestre onde foram incorporadas réplicas de implantes em aço inoxidável, e então foram realizados os procedimentos de enceramento, inclusão e acabamento das estruturas metálicas. Foram enceradas 20 amostras, padronizadas em forma e tamanho, sendo 10 fundidas em titânio comercialmente puro (Rematitan-Dentaurum, Pforzhein-Germany) e 10 em liga de paládio-prata (Pors-on 4-Degussa). As amostras foram divididas em 04 grupos, sendo: Grupo I: 05 estruturas fundidas em peça única em liga de paládio-prata; Grupo II: 05 estruturas fundidas em liga de paládio-prata, previamente seccionadas e submetidas à soldagem a laser; Grupo III: 05 estruturas fundidas em peça única de titânio e Grupo IV: 05 estruturas fundidas em titânio, previamente seccionadas e submetidas à soldagem a laser. As análises e mensurações das interfaces foram efetuadas tanto nas peças em monobloco quanto nas soldadas a laser, utilizando microscópio mensurador (STM Digital - OLYMPUS - Japan). Sendo as mesmas efetuadas na região vestibular (V) e lingual (L) da interface implante/prótese dos três implantes previamente denominados com letras A, C e E. Os dados foram submetidos análise de variância e ao teste de Tukey (p<0,05). Os resultados indicaram que: as estruturas fundidas em monobloco nos cilindros centrais apresentaram maior interface (desajuste médio de 151,392 mm) que as soldadas a laser (34,739 mm). Também foram encontradas diferenças estatisticamente significantes entre os materiais utilizados, sendo que a liga de paládio-prata (66,301 mm) apresentou melhores resultados que o titânio (119,831 mm). Nos cilindros distais, os resultados mostraram não haver diferenças estatisticamente significantes entre as estruturas fundidas em titânio e paládio-prata, na técnica monobloco. No entanto, foram encontradas diferenças estatisticamente significantes entre os dois materiais, após a soldagem a laser, sendo que o titânio (31,37 mm) apresentou melhores resultados que a liga de paládio-prata (106,59 mm). Houve também diferenças estatisticamente significantes entre as técnicas monobloco e soldagem a laser para ambos os materiais, sendo os melhores resultados para a técnica de soldagem à laser / Abstract: The aim of this study was to evaluate passive fit in titanium and palladium-silver, made by the one-piece casting technique and laser welding. By means of a metallic matrix containing five implants (3.75 X 13mm), a master model was obtained and implant replies were incorporated into it, then, wax up, inclusion and polishing was performed in the metallic structures. Twenty standardized samples, in shape and size, were waxed up; ten samples were cast in commercially pure titanium (Rematitan Dentaurum, Pforzhein-Germany), the other ten specimens were cast in palladium-silver alloy (Pors-on 4-Degussa). The samples were separated in four groups: Group I: five single structures cast in palladium-silver alloy; Group II: five structures, that were previously sectioned and underwent to laser welding, were cast in palladium-silver alloy; Group III: five single structures that were cast in titanium; and Group IV: five structures, that were previously sectioned and underwent to laser welding, were cast in titanium. The interfaces evaluations and measurements were performed both in one-piece castings and the laser welded structures, using a microscope. Data were submitted to ANOVA and Tukey's test (p<0.05). According to the results, one-piece casting structures showed higher interface (mean desajustment of 151.392 mm) in comparison to the structures welded in laser (34.739 mm). Concerning the materials, it was also found statistically significant difference, palladium-silver alloy (66.301 mm) showed better results than titanium (119.831 mm). In relation to the distal cylinders, the structures cast in titanium and palladium-silver alloy didn't present statistically significant differences, for the one-piece casting technique. However, statistically significant differences between these materials were found after laser welding. Titanium presented better results (31.37 mm) compared to palladium-silver alloy (106.59 mm). With respect to the one piece casting and laser welding techniques, there were also statistically significant differences between this two materials / Mestrado / Protese Dental / Mestre em Clínica Odontológica
45

Estudo cefalometrico do posicionamento de dentes artificiais em proteses totais duplas confeccionadas pela tecnica da zona neutra

Silva, Almenara de Souza Fonseca 03 August 2001 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T08:34:54Z (GMT). No. of bitstreams: 1 Silva_AlmenaradeSouzaFonseca_D.pdf: 4253050 bytes, checksum: 24c4e76e39bad8efc60fb7555a293658 (MD5) Previous issue date: 2001 / Resumo: O objetivo deste estudo foi avaliar a posição ocupada pelos dentes artificiais em próteses totais duplas confeccionadas pela técnica da Zona Neutra, por meio de análises cefalométricas e posteriormente, comparar os dados obtidos com os padrões considerados como normais para indivíduos dentados. Foram avaliados 28 indivíduos saudáveis, previamente reabilitados com próteses totais duplas, do sexo feminino, raça branca, com idade variando entre 55 e 65 anos e que não apresentavam sinais e sintomas clínicos de desordens temporomandibulares. Após a instalação das próteses e o período de adaptação, foram tomadas duas telerradiografias, uma em norma frontal e outra lateral, em oclusão cêntrica, com as superfícies dentárias previamente marcadas com uma substância de contraste radiográfico. Posteriormente foram executados traçados cefalométricos pelo método manual e realizadas as mensurações lineares e angulares correspondentes aos parâmetros considerados de importância para o trabalho. Os resultados foram analisados utilizando-se o intervalo de confiança para a média ao nível de 95%, sendo esses intervalos comparados com os padrões de normalidade estabelecidos pelas análises, indicando assim, diferenças significativas ou não. Os valores médios referentes à posição ântero-posterior dos incisivos centrais superior (99,84mm) e inferior (97,39mm); a inclinação do incisivo inferior em relação à mandíbula (93,89°); a dimensão transversal inter-molares (53,91mm) e a relação dos primeiros molares inferiores esquerdo (10,79mm) e direito (10,45mm) em relação ao complexo maxilomandibular não apresentaram diferença significativa, considerando-se o intervalo de confiança de 95% para a média, quando comparados com os padrões de normalidade, que eram respectivamente: 94,1mm '+ OU ¿' 5,05; 90,0mm '+ OU ¿' 5,33; 90° '+ OU ¿' 5; 54mm '+ OU ¿' 2 e 11,6mm '+ OU ¿' 2, para ambos os lados. A inclinação do incisivo central superior em relação à maxila (98,79°) e a posição ântero-posterior do primeiro molar superior (23,41mm), quando comparadas ao padrão de normalidade, que era respectivamente de 112° '+ OU ¿' 6 e 18mm '+ OU ¿' 3, foram significativamente diferentes, considerando-se uma confiança de 95%. Foi observada uma correlação negativa ('alfa¿ '< OU =¿ 0,01) entre o ângulo goníaco e a inclinação do incisivo central inferior em relação à mandíbula. Pôde-se concluir que os dentes artifíciais montados em próteses totais duplas, confeccionadas pela técnica da Zona Neutra encontram-se em uma posição vestíbulo-língual compatível com aquela ocupada pelos dentes naturais e os dentes anteriores inferiores apresentam uma redução na inclinação à medida que ocorre o aumento nos valores do ângulo goníaco, seguindo a mesma tendência observada em indivíduos dentados / Abstract: The object of this study was to evaluate the artificial teeth position in double complete dentures constructed by Neutral Zone technique, through cephalometrics analysis and then to compare the data obtained to cephalometrics standards considered as normal for dentate subjects. Twenty eight healthy subjects, of female sex, white race, who received double complete dentures, with range in age from 55 to 65 years and without signs and symptoms of temporomandibular dysfunction were evaluated. After insertion of dentures and the adaptation period, two teleradiographys, at frontal and lateral norms were made in centric occlusion, with the dental surfaces previously marked with a radio-opaque substance. They were made cephalometrics tracing by manual method and obtained the linear and angular measurements of the parameters considered important for the work. The results were analyzed by onfidence interval for the average at levei of 95% and these intervals were compared to cephalometrics standards, showing the significant difference or not. The average of the anteroposterior position of the upper central incisor (99.84mm) and lower (97.39mm); the inclination of lower incisor to the mandibula (93.89°); the intermolar width (53.94mm) and the relation of left lower first molar (10.79mm) and right (10.45mm) to fronto denture plane did not show any significant difference, by 95% confidence interval, when compared to cephalometrics standards, which are respectively 94.1mm '+ or ¿' 5.05; 90.0mm '+ or¿' 5.33; 90° '+ or ¿' 5; 54mm '+ or ¿' 2 e 11.6mm '+ or ¿' 2 for both side. The inclination of upper incisor to maxilla (98.79°) and the anteroposterior position of the upper first molar (23.41mm), when compared to standards, that are respectively 112° '+ or ¿' 6 and 18mm '+ or ¿' 3, were significant different, by confidence of 95%. It was found a negative correlation ('alfa¿ '< or =¿ 0.01) between gonial angle and inclination of lower central incisor to mandibula. It could conclude that the artificial teeth arranged in double complete dentures constructed by Neutral Zone technique are in a buccolingual position compatible with that occupied for the natural teeth and the lower anterior teeth presented a decrease inclination as increase the values of gonial angle, following the same tendency observed in dentate subjects / Doutorado / Protese Dental / Doutor em Clínica Odontológica
46

Efeito de agentes quimicos para limpeza de proteses sobre a alteração de peso de material reembasador resiliente temporario

Feitosa, Maria Aurea Lira 13 February 2001 (has links)
Orientadores: Altair A. Del Bel Cury, Renata Cunha Matheus R. Garcia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T13:10:53Z (GMT). No. of bitstreams: 1 Feitosa_MariaAureaLira_M.pdf: 10196962 bytes, checksum: 10b8701068a6ffafaae9228fdc228ae2 (MD5) Previous issue date: 2001 / Resumo: O objetivo desta pesquisa foi avaliar a alteração de peso do material reembasador resiliente temporário Coe-80ft quando armazenado em saliva artificial e submetido a tratamentos com os agentes químicos para limpeza de próteses Polident e Efferdent. Assim, foram confeccionadas 48 amostras do material resiliente que foram divididas aleatoriamente em quatro grupos, dois experimentais (G3 e G4) e dois controles (G1 e G2) e armazenadas em saliva artificial à temperatura de 37 ± 2°C durante todo o período estudado. As amostras dos grupos experimentais foram imersas diariamente nas soluções de Polident (G3) e Efferdent (G4), por 5 e 15 minutos, respectivamente e, as dos grupos-controle (G1 e G2) em água, por um período de 15 dias. As avaliações de peso foram realizadas imediatamente após confecção das amostras (To), após 24 horas (T1), com 7dias (T2) e 15 dias (T3). Os resultados (médias ± dp)para a perda de peso do material (mg) comparando-se os grupos em cada tempo (letras maiúsculas) e a influência do tempo (letras minúsculas) para cada grupo foram: G1=2,71 ± 0,08Aa; 2,65 ± 0,08Ab; 2,63 ± 0,08Abc; 2,60 ± 0,11Ac; G2=2,66 ± 0,08Aa; 2,61 ± 0,09Ab; 2,58 ± 0,08Ac; 2,57 ± 0,08Ad; G3=2,65 ± 0,14Aa; 2,60 ± 0,14Ab; 2,58 ± 0,14Ac; 2,57 ± 0,14Ad; G4=2,63 ± 0,11Aa; 2,58 ± 0,11Ab; 2,55 ± 0,11Ac; 2,54 ± 0,11Ad. Médias seguidas de letras distintas diferem estatisticamente entre si (p<0,05) pelo teste de Tukey. Com base nos resultados obtidos foi possível concluir que o material reembasador resiliente Coe-Soft quando imerso em saliva artificial perdeu peso antes do início do tratamento com os agentes químicos para limpeza da próteses e esta perda prosseguiu durante todo o período estudado, independentemente do tratamento empregado / Abstract: The purpose of this study was to evaluate the weight variation of Coe-80ft resilient material when stored in artificial saliva and submitted to treatments with Polident and Efferdent chemical denture cleansers. Forty-eight samples made of resilient material were divided, randomly, in four graups: two experimental (G3 and G4) and two contrai graups (G1 and G2), that were immersed in artificial saliva and kept at 37 ± 2°C temperature during the whole period of the study. The samples of the experimental graups were immersed daily in Polident or Efferdent solutions for 5 and 15 minutes, respectively, and the samples of the contrai were immersed in water, during a period of 15 days. The rates of weight were accomplished just after the samples were made (To), after 24 hours (T 1), with 7 days (T2) and 15 days (T3). The results (means and standard deviation) for the weight loss of material (mg) comparing the graups in each time (capitalletters) and the influence of time (small letters) for each graup were: G1=2,71±0,08Aa; 2,65 ± 0,08Ab; 2,63 ± 0,08Abc; 2,60 ± 0,11Ac; G2=2,66 ± 0,08Aa; 2,61 ± 0,09Ab; 2,58 ± 0,08Ac; 2,57 ± 0,08Ad; G3=2,65 ± 0,14Aa; 2,60 ± 0,14Ab; 2,58± 0,14Ac; 2,57 ±0,14Ad; G4=2,63 ±0, 11Aa; 2,58 ±0,11Ab; 2,55 ± 0,11Ac; 2,54 ± 0,11Ad. Means followed by different letters are statistically different themselves (p<0,05) by Tukey test. Based on these results it was possible concluded that the Coe-Soft liner resilient, when it is immersed in artificial saliva it lost weight before the beggining of 3 treatment with cleanser agents for dentures and the weight loss proceded during ali the time studied period, independently of the treatment used. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
47

Função oral e qualidade de dieta : influencia de fatores estomatognaticos e socio-demograficos

Shinkai, Rosemary Sadami Arai 18 October 2001 (has links)
Orientador : Altair A. Del Bel Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T23:17:27Z (GMT). No. of bitstreams: 1 Shinkai_RosemarySadamiArai_D.pdf: 3978741 bytes, checksum: bb292ede4a32f6dd1d01afd036dc453b (MD5) Previous issue date: 2001 / Resumo: Estudos anteriores sobre o impacto da saúde bucal e da função oral na escolha e ingestão de alimentos apresentaram resultados contraditórios. Este trabalho, composto por três manuscritos, teve por objetivo explorar a relação entre função oral e qualidade de dieta em indivíduos com diferentes tipos de condições bucais. O primeiro capítulo estudou a influência de variáveis mastigatórias e de fatores sócio-demográficos na qualidade de dieta de indivíduos dentados e edentados. O segundo artigo avaliou se a deficiência técnica de próteses totais em termos de retenção, estabilidade e desgaste de dentes artificiais está relacionada à diminuição da performance mastigatória, à percepção de dificuldades em mastigar e à qualidade de dieta insatisfatória. O terceiro manuscrito abordou a relação entre função mastigatória, qualidade de dieta e problemas digestivos em pacientes de cirurgia ortognática. Os resultados destes estudos demonstraram que a qualidade de dieta não foi determinada pelas condições oclusais ou pelo grau de função oral. Quanto pior as condições oclusais, pior é a eficiência de função oral em termos de performance mastigatória e força de mordida. Em relação a próteses totais, próteses com qualidade técnica adequada permitiram um desempenho funcional superior às próteses com deficiências técnicas. Entretanto, não há reflexo na percepção de capacidade mastigatória ou na qualidade de dieta e adequação nutricional. Independentemente das condições oclusais, da qualidade técnica das próteses totais ou do grau de função oral, a maioria dos indivíduos apresentou qualidade de dieta deficiente / Abstract: Previous studies about the impact of oral health and oral function on diet and food choices have shown contradictory results. This study, which is composed by three manuscripts, aimed to explore the relationship between oral function and diet quality in subjects with different oral conditions. The first chapter studied the influence of masticatory and sociodemographic variables on diet quality of dentate and edentulous subjects. The second paper evaluated if poor quality of complete dentures, in terms of retention, stability, and artificial tooth wear, is related to decreased masticatory performance, perceived difficulties in ability to chew, and poor diet quality. The third manuscript analyzed the relationship among oral function, diet quality, and digestive problems in orthognathic surgery patients. The results of these studies showed that diet quality was determined neither by occlusal conditions nor by the leveI of oral function. The worse the occlusal conditions, the worse the efficiency of oral function regarding masticatory performance and bite force. In relation to complete dentures, good quality complete dentures allowed superior functional performance compared to poor quality prostheses. However, this did not reflected in perception of masticatory ability or in diet quality and nutrition adequacy. The majority of subjects had deficient diet qualities independently of occlusal conditions, technical quality of complete dentures, and level of oral function / Doutorado / Protese Dental / Doutor em Clínica Odontológica
48

Analise da deformação de componentes de protese fixa implantossuportada quando submetidos a cargas axiais e obliquas por meio de extensometria / Analysis of the deformation of the components of implant-suported prosthesis when submitted to axial and obliques loads by mean of the extensometry

Costa, Marcelo de Almeida 02 November 2009 (has links)
Orientador: Wilkens Aurelio Buarque e Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T03:30:15Z (GMT). No. of bitstreams: 1 Costa_MarcelodeAlmeida_D.pdf: 2169259 bytes, checksum: 40e31d0384a05e3f5b7c97d6657b6364 (MD5) Previous issue date: 2009 / Resumo: Este trabalho teve como objetivo, avaliar através da extesometria, a resposta de forças aplicadas sobre abutments de infra-estrutruras implanto-retidas fundidas em ligas de cobalto-cromo, pela técnica de monobloco, simulando caso de protocolo mandibular, foram utilizados 06 implantes com distância de 10 mm entre implantes e com extremo livre Cantilever bilateral com tamanho do 20 mm. Em cada abutment foram colados 04 extensometros, fazendo uma ponte de Wheatstone, após apertamento de todos os componentes a peça em monobloco, foi submetido a um ensaio mecânico com cargas compressivas com valores de 150 N/cm, analisando quantitativamente os dados através da extensômetria, permitindo resultados bem precisos. Os referidos resultados foram obtidos usando os maiores valores registrados em cada ponto de força aplicado, ou seja, nos lados: esquerdo e direito ( cantilever bilateralmente), tanto para carga axial ou em 20º, demonstrou pura deflexão, porem quando a aplicação foi entre as fixações( implantes ) P1eP2,P3eP4,P4 eP5, P5eP6, respectivamente, foi obtido nas fixações mais próximas a aplicação da carga um maior grau de compressão (deflexão) e nas fixações mais distantes uma pequena deflexão negativa indo até conseguir uma deflexão positiva, sugerindo movimento de gangorra / Abstract: The objective of this study was evaluate through extensometry the response of implant-suported frameworks in cobalt-chromium submitted to a load by the technique of monoblock, that simulate a case of mandibular protocol with 06 implants with a distance of 10 mm between each implant and a bilateral cantlever of 20 mm. In each abutment were pasted 04 strain gauges, making a bridge of Wheatstone, after squeezing all components of the piece of the monoblock, was submitted to a test with mechanical compressive loads with values of 150 N, quantitatively analyzing the data through extensometry, allowing accurate results. The results were obtained using the highest values recorded at each point of force applied, in the points L and R (cantilever bilaterally) for both axial load or 20, showed pure deflection, but when the load was applyed between p1 and p2, P3eP4, P4 eP5, P5eP6 respectively, was obtained a greater degree of compression (deflection) closer to the application of the load and more dstant to the applicarion of load, a little negative deflection was found by going to a positive deflection, suggesting movement of seesaw / Doutorado / Protese Dental / Doutor em Clínica Odontológica
49

Avaliação da adaptação vertical entre intermediários do tipo esteticone e cilindros metálicos pré-usinados, variando as condições: sobrefundição, torques e parafusos de fixação

Luciana Martins Crês Moraes 27 August 2003 (has links)
A adaptação de próteses sobre implantes é considerada um fator primordial para o sucesso destas longitudinalmente. Este estudo observou a adaptação vertical entre intermediário tipo esteticone e cilindros pré-fabricados antirotacionais para próteses unitárias em diferentes ligas. Foram selecionados cilindros de ouro da empresa Conexão (Conexão Sistemas de Prótese - São Paulo- SP- Brasil) e cilindros de níquel/cromo pré-fabricados em um laboratório comercial. A mensuração da adaptação vertical foi realizada em microscópio óptico, antes da sobrefundição, ao torque de 10Ncm e 20Ncm variando-se os parafusos de fixação. Encontraram-se medidas que variaram de 14,02 ± 5,63 µm para os cilindros de níquel/cromo, antes da sobrefundição ao torque de 10Ncm, e 10,95 ± 5.68 µm para o torque de 20Ncm. E para os cilindros de ouro, ao torque de 10Ncm, a média encontrada foi de 14,41 ± 3,84 µm e ao torque de 20Ncm foi de 12,26 ± 3.69 µm. Após as leituras iniciais, os cilindros receberam enceramento, foram incluídos e fundidos com ligas de paládio/prata para o cilindro de ouro, e níquel/cromo para o cilindro de níquel/cromo e novamente analisados. As medidas variaram de 20,93 ± 7,10 µm a 10Ncm e 15,77 ± 4,72 µm a 20Ncm para os cilindos de níquel/cromo fundidos em níquel /cromo, e de 11,79 ± 4,06 µm ao torque de 10Ncm e 9,59 ± 3,25 µm à 20Ncm para os cilindros de ouro sobrefundidos em paládio/prata. Os resultados obtidos demonstraram que o cilindros de ouro com maior torque apresentaram-se mais adaptados antes e após a sobrefundição. Foram encontradas diferenças estatisticamentes significantes também quando a liga de paládio/prata foi empregada. Concluiu-se então que as próteses unitárias sobre implantes são indicadas sendo que ligas nobres e seminobres apresentam menores variações estruturais. / The fitting of prostheses over implants is regarded as a fundamental factor for their success in the long-term. This study evaluated the vertical fitting between esteticone abutments and anti-rotational prefabricated cylinder implants of several alloys for single-tooth prosthesis. Gold cylinders of the brand Conexao (Conexao Sistemas de Protese – Sao Paulo, SP, Brazil) and nickel-chromium cylinders prefabricated in a commercial laboratory were selected. Measurement of the vertical fitting was conducted in a light microscope, before overcasting with 10 Ncm and 20 Ncm of torque, with variations in the fixing screws. The measurements ranged from 14.03±5.63µm for the nickel-chromium cylinders before overcasting with 10 Ncm of torque and 10.95±5.68µm with 20 Ncm of torque. Concerning the gold cylinders, the values found were 14.41±3.84µm with 10 Ncm of torque and 12.26±3.69µm with 20 Ncm of torque. After the initial readings, the cylinders were submitted to waxing, investment and casting with palladium-silver alloy for the gold cylinders and nickel-chromium alloy for the nickel-chromium cylinders, and then reevaluated. The measurements revealed 20.93±7.10µm with 10 Ncm and 15.77±4.72µm with 20 Ncm for the nickelchromium cylinders cast with nickel-chromium, and 11.79±4.06µm with 10 Ncm and 9.59±3.25µm with 20 Ncm for the gold cylinder overcast with palladium-silver. The results demonstrated that the gold cylinders with the higher torque exhibited the best fitting before and after overcastting. Statistically significant differences were also observed with employment of the palladium-silver alloy. It was concluded that single-tooth implant-supported prosthesis may be indicated, being that noble and semi noble alloys present the smallest structural variations.
50

Dimensão vertical de oclusão em desdentados totais obtida pelos métodos de Tamaki de Beresin & Schiesser: estudo comparativo.

Rudys Rodolfo De Jesus Tavarez 08 August 1997 (has links)
A dimensão vertical de oclusão obtida pelos métodos de Tamaki e de Beresin & Schiesser; e a altura das próteses que os pacientes utilizavam, foram determinadas em uma amostra de 30 pacientes desdentados totais superior e inferior, com idade entre 38 e 77 anos; apresentando prótesis totais duplas totais em uso por um período mínimo de cinco anos, rebordos alveolares clinicamente favoráveis, ausência de sintomas de desordens temporomandibulares, com movimentos mandibulares normais. Os valores obtidos em cada um dos métodos testados foram comparados e relacionados com as alturas encontradas nas próteses que os pacientes utilizavam. Os resultados obtidos permitiram concluir que: 1) houve diferença estatisticamente significante em nível de 0,01 %, quando se compararam os valores obtidos pelos dois métodos; 2) quando comparados os métodos de Tamaki e Beresin & Schiesser em relação as alturas das próteses utilizadas, pode-se observar uma diferença média positiva de 3,02mm e 4,40mm respectivamente. / The vertical dimension of oclussion obtained by Tamaki’s and Beresin & Schiesser’s methods and the height of the complete dentures used by the patiens were obtained in a 30 edentulous persons sample with ages ranging from 38 to 77 years old, that had been wearing superior and inferior complete dentures for at least 5 years, in hose residual ridges were clinically favorable, and showing normal mandibular movements and absence of temporomandibular disordens. The purpose of this study was comparing the values obteined in each of the tested methods and correlating them with the heights taken of the dentures usedby the patients. As so checking the correspondence grade existing in each one. The results showed that: 1) There was statistically significant difference when comparing the values obteined in the two methods; being that there was a great correlation between these values to the leve of 0,01 %; 2) When comparing Tamaki’s and Beresin & Schiesser’s methods in relation to the heights of dentures used, a positiver medium difference could be observed, of 3.02mm and 4.40mm respectively.

Page generated in 0.0438 seconds