• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1509
  • 69
  • 69
  • 69
  • 69
  • 49
  • 17
  • 11
  • 11
  • 10
  • 7
  • 5
  • 3
  • 2
  • 2
  • Tagged with
  • 1536
  • 774
  • 497
  • 457
  • 365
  • 347
  • 292
  • 240
  • 219
  • 198
  • 187
  • 185
  • 175
  • 168
  • 141
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação da adaptação vertical entre intermediários do tipo esteticone e cilindros metálicos pré-usinados, variando as condições: sobrefundição, torques e parafusos de fixação

Moraes, Luciana Martins Crês 27 August 2003 (has links)
A adaptação de próteses sobre implantes é considerada um fator primordial para o sucesso destas longitudinalmente. Este estudo observou a adaptação vertical entre intermediário tipo esteticone e cilindros pré-fabricados antirotacionais para próteses unitárias em diferentes ligas. Foram selecionados cilindros de ouro da empresa Conexão (Conexão Sistemas de Prótese - São Paulo- SP- Brasil) e cilindros de níquel/cromo pré-fabricados em um laboratório comercial. A mensuração da adaptação vertical foi realizada em microscópio óptico, antes da sobrefundição, ao torque de 10Ncm e 20Ncm variando-se os parafusos de fixação. Encontraram-se medidas que variaram de 14,02 ± 5,63 µm para os cilindros de níquel/cromo, antes da sobrefundição ao torque de 10Ncm, e 10,95 ± 5.68 µm para o torque de 20Ncm. E para os cilindros de ouro, ao torque de 10Ncm, a média encontrada foi de 14,41 ± 3,84 µm e ao torque de 20Ncm foi de 12,26 ± 3.69 µm. Após as leituras iniciais, os cilindros receberam enceramento, foram incluídos e fundidos com ligas de paládio/prata para o cilindro de ouro, e níquel/cromo para o cilindro de níquel/cromo e novamente analisados. As medidas variaram de 20,93 ± 7,10 µm a 10Ncm e 15,77 ± 4,72 µm a 20Ncm para os cilindos de níquel/cromo fundidos em níquel /cromo, e de 11,79 ± 4,06 µm ao torque de 10Ncm e 9,59 ± 3,25 µm à 20Ncm para os cilindros de ouro sobrefundidos em paládio/prata. Os resultados obtidos demonstraram que o cilindros de ouro com maior torque apresentaram-se mais adaptados antes e após a sobrefundição. Foram encontradas diferenças estatisticamentes significantes também quando a liga de paládio/prata foi empregada. Concluiu-se então que as próteses unitárias sobre implantes são indicadas sendo que ligas nobres e seminobres apresentam menores variações estruturais. / The fitting of prostheses over implants is regarded as a fundamental factor for their success in the long-term. This study evaluated the vertical fitting between esteticone abutments and anti-rotational prefabricated cylinder implants of several alloys for single-tooth prosthesis. Gold cylinders of the brand Conexao (Conexao Sistemas de Protese – Sao Paulo, SP, Brazil) and nickel-chromium cylinders prefabricated in a commercial laboratory were selected. Measurement of the vertical fitting was conducted in a light microscope, before overcasting with 10 Ncm and 20 Ncm of torque, with variations in the fixing screws. The measurements ranged from 14.03±5.63µm for the nickel-chromium cylinders before overcasting with 10 Ncm of torque and 10.95±5.68µm with 20 Ncm of torque. Concerning the gold cylinders, the values found were 14.41±3.84µm with 10 Ncm of torque and 12.26±3.69µm with 20 Ncm of torque. After the initial readings, the cylinders were submitted to waxing, investment and casting with palladium-silver alloy for the gold cylinders and nickel-chromium alloy for the nickel-chromium cylinders, and then reevaluated. The measurements revealed 20.93±7.10µm with 10 Ncm and 15.77±4.72µm with 20 Ncm for the nickelchromium cylinders cast with nickel-chromium, and 11.79±4.06µm with 10 Ncm and 9.59±3.25µm with 20 Ncm for the gold cylinder overcast with palladium-silver. The results demonstrated that the gold cylinders with the higher torque exhibited the best fitting before and after overcastting. Statistically significant differences were also observed with employment of the palladium-silver alloy. It was concluded that single-tooth implant-supported prosthesis may be indicated, being that noble and semi noble alloys present the smallest structural variations.
22

Estudo da proporção áurea em indivíduos edêntulos antes e depois do tratamento por próteses totais por meio de radiografias cefalométricas laterais e fotografias /

Costa, Carolina Bacci. January 2012 (has links)
Orientador: Julio Cezar de Melo Castilho / Banca : Evelise Ono / Banca: Mônica Costa Armond / Banca: Tarcísio José de Arruda Paes Júnior / Banca: Janete Dias Almeida / Resumo: O propósito neste estudo radiográfico e fotográfico foi avaliar razões entre estruturas ósseas e em tecido mole da face de indivíduos edêntulos, antes e depois do tratamento por próteses totais e compará-las à proporção áurea. Os valores de algumas razões também foram correlacionados entre as análises radiográfica e fotográfica. Foram selecionados 54 indivíduos desdentados totais que realizaram o tratamento reabilitador por próteses totais na Faculdade de Odontologia de São José dos Campos-UNESP, durante o período letivo de 2010. Foram obtidas duas radiografias cefalométricas laterais, duas fotografias na norma lateral e duas fotografias na norma frontal de cada indivíduo, sendo a primeira sem as próteses e a segunda com as novas próteses totais em posição. Foram avaliadas 4 razões nas radiografias cefalométricas laterais denominada análise áurea 1-AA1- (Or-Me/Co-Go; Or-Me/Ena-Enp; Or-Me/N-Ena; N-Me-Ena-Me), 5 razões nas fotografias laterais -AA2- (Tr-Me'/Tr-Sn; Tr-Me'/N'-Me'; Tr-Sn/Sn-Me'; Sn-Me'/St-Me'; N'-Sn/St-Me') e 5 razões nas fotografias frontais -AA3- (Tr-Me'/DN-Me'; DN-Me'/Tr-DN; Tr-PN/PN-Me'; PN-Me'/DN-PN; Ls-Me'/PN-Ls). Realizouse o teste t-pareado para comparar as médias antes e depois do tratamento por próteses totais e o teste t de Student para comparar as médias de cada razão ao número áureo (1,618). As razões das análises AA1, AA2 e AA3 apresentaram diferenças estatisticamente significantes antes e depois do tratamento, com exceção das razões Sn-Me'/St-Me' e DN-Me'/Tr-DN. As razões Or-Me/Co-Go (depois do tratamento) e Tr- Me'/DN-Me' (antes do tratamento) foram consideradas estatisticamente iguais ao número áureo. Observou-se correlação estatisticamente significante (p<0,05) somente entre as razões Or-Me/Ena-Enp e Tr- Me'/Tr-Sn, antes e depois... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate ratios in the face of edentulous subjects, between bone structures and soft tissue, before and after prosthetic treatment. The ratios were compared to the golden number (1,618) and verified correlations in ratios in x-rays and photographs analysis. Fifty-four edentulous subjects were selected and the complete dentures were made by School of Dentistry's students, from Unesp - Univ Estadual Paulista. Two lateral cephalometric x-rays, two lateral photographs and two frontal photopraphs of each subject were obtained (the first without the complete dentures, in mandibular rest position, and the second, in occlusion). The ratios evaluate in lateral cephalometric xrays were Or-Me/Co-Go; Or-Me/Ena-Enp; Or-Me/N-Ena; N-Me-Ena-Me; in lateral photographs Tr-Me'/Tr-Sn; Tr-Me'/N'-Me'; Tr-Sn/Sn-Me'; Sn-Me'/St- Me'; N'-Sn/St-Me' and in frontal photographs Tr-Me'/DN-Me'; DN-Me'/Tr- DN; Tr-PN/PN-Me'; PN-Me'/DN-PN; Ls-Me'/PN-Ls. The means of each ratio were statistically analysed by paired t-test and Student's t-test, and compared with the golden number 1,618. There were statistically significant in ratios before and after prosthetic treatment, except for the ratios Sn-Me'/St-Me' and DN-Me'/Tr-DN. The ratios Or-Me/Co-Go (after complete denture) and Tr-Me'/DN-Me' (before complete denture) were considered statistically equal to the golden number. There was a statistically significant correlation (p <0.05) between the ratios Or-Me/Ena- Enp and Tr-Me'/ Tr-Sn before... (Complete abstract click electronic access below) / Doutor
23

Análise qualitativa dos fatores funcionais e psicossociais relacionados ao uso de próteses totais fabricadas pelas técnicas covencional e CD4

Dalberto, Charlene da Silveira January 2015 (has links)
A implantação dos Laboratórios Regionais de Prótese Dentária (LRPD), através do Programa Brasil Sorridente, foi um importante passo para a abordagem da necessidade crescente de reabilitação protética da população idosa brasileira. Apesar dos incentivos à expansão dos LRPDs, há uma grande parcela da população edêntula com demanda reprimida de próteses totais. Assim, a aplicação de uma técnica abreviada para a fabricação de próteses totais em quatro sessões clínicas (CD4) pode otimizar o processo de reabilitação oral nos serviços de saúde. O objetivo desse estudo foi explorar e compreender as percepções dos aspectos funcionais e psicossociais relacionados ao uso de próteses totais fabricadas pelas técnicas convencional e CD4, por meio de uma abordagem qualitativa. Para isso, foram selecionados 20 participantes entre os pacientes que procuraram atendimento para reabilitação com prótese total dupla na Faculdade de Odontologia da Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, Brasil. Os participantes foram randomizados em dois grupos e reabilitados com próteses totais convencionais (C), de seis sessões clínicas, e CD4, de quatro sessões clínicas. Após 6 meses da instalação e uso das novas próteses, foram realizadas entrevistas individuais abertas baseadas em um roteiro semiestruturado. As entrevistas foram registradas em gravações de áudio no formato mp3 e os participantes foram identificados por códigos (P1 ao P20) para o cegamento dos avaliadores. Os áudios das entrevistas foram transcritos e importados para um software de análise qualitativa (NVivo). As transcrições foram analisadas com base nos procedimentos e critérios inspirados na Teoria Fundamentada em Dados, de acordo com Strauss e Corbin. O processo de análise iniciou pela definição de conceitos e formação de categorias, seguido do agrupamento em domínios, e determinação das interações e dimensões. Os resultados foram refinados para a identificação de uma categoria central que integrou as demais categorias. Dez categorias foram identificadas e agrupadas em dois domínios: Funcional (Mastigação, Desconforto e dor, Estabilidade e retenção das próteses, Fonética) e Psicossocial (Resiliência, Estratégias de enfrentamento (coping), Emoções, Autoimagem e Interação social). E, em um nível maior de abstração, a Satisfação com as próteses emergiu como fenômeno central do uso das próteses de ambas técnicas. De acordo com os resultados, os fatores psicológicos influenciaram a Satisfação com o uso de próteses totais, através da interação entre os domínios Funcional e Psicossocial mediada pela Resiliência e as Estratégias de enfrentamento. Essa interação pode ter impacto sobre a capacidade positiva de adaptação do paciente ao uso de novas próteses, independentemente da técnica de fabricação. As percepções sobre os aspectos funcionais e psicossociais dos pacientes reabilitados a partir da técnica CD4 foram similares às dos que usaram próteses convencionais após 6 meses de uso das próteses, sem desvantagens quanto à satisfação final com o tratamento reabilitador. Portanto, as próteses totais convencionais e CD4 não apresentaram diferenças funcionais e psicossociais sob a percepção dos participantes.
24

Limitação de atividades em idosos: estudo em novos usuários de próteses auditivas por meio do questionário APHAB / Limitation of activities in the elderly: a study in new users of hearing aids through the questionnaire APHAB

Flores, Nayyara Glícia Calheiros [UNIFESP] 31 March 2010 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:24Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-31 / Objetivo: Avaliar as limitações auditivas de idosos, com o uso de próteses auditivas, em atividades de vida diária, por meio do questionário APHAB, segundo as variáveis escolaridade e grau da perda auditiva. Métodos: Este estudo foi realizado em dois serviços de Alta Complexidade da rede estadual de atenção à Saúde Auditiva do estado de Alagoas. Foram avaliados 30 idosos com perda auditiva sensorioneural de grau moderado e moderadamente severo, novos usuários de próteses auditivas. O questionário de auto-avaliação Abbreviated Profile of Hearing Aid Benefit foi aplicado sem a prótese auditiva e após três meses de uso. Foi utilizado o teste de Wilcoxon para comparar os escores por sub-escala e a avaliação geral foi calculada pelas respostas das sub-escalas Facilidade de Comunicação, Reverberação e Ruído Ambiental. O benefício obtido com o uso da prótese auditiva foi obtido pela subtração dos resultados na avaliação geral sem prótese auditiva e com prótese auditiva. Para o estudo da associação entre o grau de escolaridade e o benefício e o grau de perda auditiva e o benefício utilizou-se o teste de Kruskal-Wallis. Os resultados foram considerados significantes quando p<0,05. Resultados: A amostra foi composta por 18 mulheres (60%) e 12 homens (40%), com idades variando entre 60 e 87 anos, média de 71,6 anos. Com relação à escolaridade, 11 idosos (36,7%) não eram alfabetizados; oito (26,7%) tinham o ensino fundamental incompleto, um (3,3%) ensino fundamental completo, seis (20%) ensino médio incompleto e quatro (13,3%) ensino médio completo. Dos 30 participantes, 19 (63,3%) apresentavam perda auditiva de grau moderado e 11 (36,7%) moderadamente severo. Comparando-se os resultados do questionário sem e com prótese auditiva, verificou-se diferença estatisticamente significante nas sub-escalas facilidade de comunicação, reverberação e ruído ambiental, com valores de p<0,001. Para a sub-escala aversão aos sons ocorreu uma piora significante com o uso da prótese auditiva. Na avaliação geral houve melhora no desempenho com o uso da prótese auditiva nas três sub-escalas: Facilidade de Comunicação, Reverberação e Ruído Ambiental. Não houve associação estatisticamente significante entre o benefício obtido com o uso da prótese auditiva e o grau de escolaridade e o grau de perda auditiva. Conclusões: Há benefício nas subescalas: Facilidade de Comunicação, Reverberação e Ruído Ambiental. Não há associação entre o benefício obtido com o uso de próteses auditivas e as variáveis escolaridade e grau da perda auditiva. O benefício obtido na sub-escala Ruído Ambiental é menor do que o obtido nas sub-escalas Facilidade de Comunicação e Reverberação. / Objective: Evaluate the hearing difficulties and the benefits of elderly with the use of hearing aids in daily life activities according to variables of educational degree and hearing loss degree. Methods: This study was carried out in two services of high complexity in the state branch of the hearing health care in the State of Alagoas, after the favorable results of the Ethic Committee of UNIFESP and UNCISAL. It was evaluated 30 elderly with sensoneural hearing loss of moderated degree to moderately severe, new users of hearing aids. The questionnaire of self-evaluation APHAB was used before the hearing aids fitting and after three months of using them. This questionnaire has 24 questions, with seven possibilities of answers, distributed in four sub-scales: easy of communication, reverberation, background noise, and aversiveness and has as its objective quantify the difficulty caused by the hearing loss as well as the reduction of this difficulty through the use of hearing aids. The data were summarized through absolute frequency (N) and relative (%) in the case of categorical and numerical variable, through average, standard deviation, median, minimum and maximal value. It was used the Wilcoxon method to compare the scores through sub scale and the general was calculated through the answers of the three sub scales. The benefic obtained with the use of the hearing aids was obtained by the subtraction of the results in the general evaluation before and after three months of fitting. To the study of association between the educational degree and the benefit and the hearing loss degree and the benefit, it was used the Kruskal-Wallis test. The results were considered to be significant when p< 0,05. The data analysis as well as the production of graphics were obtained through the use of the software statistics Minitab, version 15.1 Results: The sample was composed by 18 women (60%) and 12 men (40%), with ages ranging 60-87,average 71,6. In relation to the educational degree, the majority were not illiterate (36,7%); eight (26,7%) had the secondary school degree incomplete, one (3,3%) had the secondary school degree complete, six(20%) high school incomplete and four (13,3%) high school complete. From the 30 participants, 19 (63,3%) shown hearing loss of moderated degree and 11 (36,7%) of severe degree. Comparing the results of the questionnaire before and after three months of fitting, it was observed a significant statistically difference in the sub scales easy of communication, reverberation and background noise with values of p< 001. To the sub scale to the aversiveness was observed a negative benefit, that is, a significant worsen happened with the use of hearing aids. In the general analysis was observed an improvement in the use of the hearing aids in the three sub scales: easy of communication, background noise and aversiveness. There was not a significant statistically association between the benefit of the hearing aids and the education degree and the hearing loss degree. Conclusions: There is a benefit in all sub scales: ease of communication, reverberation, aversiveness and background noise. There is nor association between the benefit obtained and the use of haring aids, and the variables education degree and hearing loss degree. The benefit obtained in the background noise sub scale is less than that obtained in the easy of communication and reverberation sub scale. / TEDE / BV UNIFESP: Teses e dissertações
25

Avaliação de fendas interfaciais de facetas cerâmicas minimamente invasivas

Siedschlag, Gustavo January 2016 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016 / Made available in DSpace on 2016-09-20T04:43:14Z (GMT). No. of bitstreams: 1 340519.pdf: 20067846 bytes, checksum: 217bd22919cc06cb7bc6895571a11ab0 (MD5) Previous issue date: 2016 / O objetivo deste estudo foi avaliar a influência do desenho do preparo de restaurações cerâmicas do tipo faceta na integridade marginal imediata e após 5 anos de envelhecimento simulado, em diferentes regiões do dente. Material e métodos. Foram selecionados 30 dentes pré-molares superiores humanos hígidos e divididos aleatoriamente em 3 grupos (n=10), de acordo com o desenho do preparo da restauração cerâmica: G1: faceta total com preparo (Convencional); G2: faceta total sem preparo (Lente de Contato); G3: faceta parcial sem preparo (Fragmento). Os preparos do G1 foram controlados por meio de guias de silicone (vertical e horizontal, 0,5 mm redução axial vestibular). Os dentes foram incluídos em resina de poliestireno com simulação do ligamento periodontal. Trinta restaurações cerâmicas de dissilicato de lítio foram produzidas utilizando tecnologia CAD/CAM com espessura padronizada 0,5 mm e espaço interno 100 µm. As restaurações cerâmicas foram cimentadas adesivamente e envelhecidas com ciclagem termo-mecânica (CTM) (1.200,000 ciclos mastigatórios; 50 N; 2 Hz; e 6.000 ciclos térmicos 5o / 55o C, 2 min cada ciclo) para simular 5 anos de serviço clínico. Os espécimes foram escaneados por microtomografia computadorizada por raios-X (Micro-CT) para análise 3D da adaptação marginal (µm) em três regiões (cervical, proximal, oclusal) antes e após a CTM. Os dados foram analisados estatisticamente pelo ANOVA de 2 fatores, seguido pelo teste de Tukey (?? = 5%). Resultados. Os resultados de adaptação marginal (µm) e desvio padrão antes a CTM para as regiões cervical, oclusal e proximal, respectivamente foram: G1 (51,5 ± 9,4; 51,5 ± 21,8; 59,7 ± 12,9), G2 (45,3 ± 9,7; 65,1 ± 11,8; 52,0 ± 7,0), G3 (55,0 ± 9,5; 84,8 ± 52,1; 48,0 ± 3,7). Após a CTM: G1 20 (105,0 ± 28,2; 120,6 ± 34,0; 65,0 ± 10,8), G2 (103,5 ± 22,7; 127,3 ± 45,4; 61,9 ± 7,6), G3 (101,9 ± 6,5; 167,5 ± 37,6; 58,5 ± 4,4). Houve maior aumento da fenda marginal para o grupo G3 na região oclusal após a CTM, acima do limite aceitável clinicamente (120 µm). A fenda marginal na região proximal foi estatisticamente menor para todos os grupos após a CTM. Conclusões. O desenho do preparo para facetas cerâmicas influenciou significativamente na formação de fendas marginais após 5 anos de envelhecimento simulado. As facetas convencionais e lentes de contato apresentaram significativamente menor aumento das fendas marginais quando comparadas aos fragmentos na região oclusal, que obtiveram resultados acima do limite aceitável clinicamente. A região proximal foi a região mais estável. <br> / Abstract : The purpose of this study was to evaluate the influence of the preparation design for ceramic veneers on the immediate marginal integrity and after 5 years of simulated aging, in different regions of the tooth. Material and methods. Thirty freshly sound human superior premolars were selected and randomly divided into 3 groups (n = 10), according to the preparation design of the ceramic veneer restoration: G1/Conventional: total veneer with preparation; G2/Contact Lens: total veneer without preparation; G3/Fragment: partial veneer without preparation. The preparations for the group Conventional were controlled by means of silicone guides (vertical and horizontal, 0.5 mm buccal axial reduction). The teeth were embedded in polystyrene resin with periodontal ligament simulation. Thirty lithium disilicate ceramic restorations were produced using CAD/CAM technology with standard thickness (0.5 mm) and internal space (100 µm). Ceramic restorations were adhesively cemented and the specimens were aged with a proven thermomechanical cycling protocol (TMC) (1200000 chewing cycles, 50 N, 2 Hz, and 6000 thermal cycles, 5/55 ° C, 2 min per cycle) to simulate five years of clinical service. All specimens were scanned by micro-computed tomography (micro-CT) for 3D analysis of the marginal adaptation (µm) in three areas (cervical, proximal, occlusal) before and after the TMC. The means were calculated and data were statistically analyzed by ANOVA two factors, followed by Tukey test (a = 5%). Results. The results of marginal fit (µm) and standard deviation before TMC for cervical, 22 occlusal and proximal regions respectively were: Conventional (51.5 ± 9.4, 51.5 ± 21.8, 59.7 ± 12.9) Contact Lens (45.3 ± 9.7, 65.1 ± 11.8, 52.0 ± 7.0), Fragment (55.0 ± 9.5, 84.8 ± 52.1; 48.0 ± 3.7). After the TMC: Conventional (105.0 ± 28.2, 120.6 ± 34.0, 65.0 ± 10.8) Contact Lens (103.5 ± 22.7, 127.3 ± 45 4; 61.9 ± 7.6), Fragment (101.9 ± 6.5, 167.5 ± 37.6, 58.5 ± 4.4). The variation before and after the TMC: Conventional (53.5 ± 29.2, 69.1 ± 53.6, 5.3 ± 5.0), Contact Lens (58.2 ± 28.2; 62 2 ± 43.4, 9.9 ± 3.7), Fragment (46.9 ± 3.0, 82.7 ± 45.8, 10.5 ± 2.5). There was a significantly greater increase in marginal gap for the group Fragment in the occlusal region after the TMC, above the clinically acceptable limit of 120 µm (p < 0.05). The marginal gap in the proximal region was significantly lower for all groups after the TMC (p < 0.05). Conclusions. The preparation design for ceramic veneers significantly influenced the marginal gaps formation after 5 years of simulated aging. Conventional and contact lens veneers presented a significantly lower increase in marginal gaps compared to fragments in the occlusal region, which revealed results above the clinically acceptable limit. The proximal region was the most stable region.
26

Avaliação da cimentação de pinos não metálicos na dentina intraradicular utilizando cimentos resinosos auto-adesivos

Roperto, Renato Cássio [UNESP] 29 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-29Bitstream added on 2014-06-13T19:01:40Z : No. of bitstreams: 1 roperto_rc_dr_arafo.pdf: 1139508 bytes, checksum: 0f0c6f68a4b263d2ab94e38cf376a35c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou por meio da microtrção (µTBS) a adesão de pinos de fibra de vidro à cimentos auto-adesivos e convencionais. Oitenta dentes humanos recém-extraídos tratados endodonticamente foram divididos em 8 grupos (n=10). Dois diferentes tipos de pinos de fibra de vidor foram utilizados; pino de fibra de vidro silanizado (Reforpost/Angelus) (RA) e pinos flexíveis de fibra de vidro silanizados (EverStick/Sticktech) (EP). Esses foram cimentados em preparos protéticos no interior dos condutos radiculares dos dentes utilizando três diferentes cimentos resinosos auto-adesivos; Unicem/3M-ESPE (UNI), Biscem/BISCO (BIS), Maxcem/KERR (MAX) e um cimento convencional com a aplicação adicional de um primer/adesivo separadamente, PanaviaF/Kuraray, (PAN) como grupo controle. Os specimens foram termociclados por 3000 ciclos, variando a temperatura da água em 5 oC - 55 oC. Depois, foram armazenados em estufa à temperature constante de 37o C. Após uma semana, os mesmos foram seccionados em fatias de 1.0 mm (3 para a região cervical, 3 para a região média das raízes). As fatias foram desgastadas mesio-distalmente e submetidas à microtração em uma máquina de testes. Os valores obtidos para cada grupo foram estatísticamente analisados utilizando ANOVA. Os resultados mostraram que uma diferença significante foi percebida entre os grupos pinos e cimentos resinosos (P < 0.001). Valores de microtração para a região media foram menores àqueles obtidos para a região cervical, porém, sem diferença estatística significante (P>0.05). Valores obtidos com EP foram maiores àqueles obtidos com RA. Conclui-se que os cimentos resinosos auto-adesivos foram capazes de produzir valores de adesividade à dentina intraradicular semelhantes ao grupo controle (cimento resinoso convencional) utilizando primer/adesivo separadamente, independente do tipo de pino utilizado. / New self-adhesive resin cements were recently made available. This study evaluated microtensile bond strength (µTBS) of two glass fiber posts to intraradicular dentin when new self-adhesive resin cements were used. Eighty freshly-extracted single-rooted anterior teeth were endodontically-treated and assigned to 8 groups (n=10). Two glass fiber posts were used, silanized glass fiber post (Reforpost/Angelus) (RA) and flexible fiber post (EverStick/Sticktech) (EP). These were cemented to prepared post spaces using three self-adhesive cements: Unicem/3M-ESPE (UNI), Biscem/BISCO (BIS), Maxcem/KERR (MAX) and a resin cement used with separate primer/bonding, PanaviaF/Kuraray, (PAN) as a control group. Specimens were thermocycled for 3000 cycles in water baths 5 oC - 55 oC. Specimens were then stored in water at 37 oC for one week and sectioned into 1.0 mm thick slices (3 from cervical, 3 from middle parts of the roots). Slices were trimmed mesio-distally and subjected to µTBS testing in a special machine. Mean µTBS of each group was calculated and data statistically-analyzed with ANOVA. The ANOVA test indicated significant differences among the groups (P < 0.001). Mean µTBS for middle dentin were consistently lower than those obtained for cervical, however, without statistical significance (P>0.05). Mean µTBS values obtained with EP were consistently higher than those obtained with RA. Some self-adhesive resin cements were capable of producing mean µTBS to radicular dentin similar to that obtained when control resin cement with separate primer /adhesive was used.
27

Estudo da proporção áurea em indivíduos edêntulos antes e depois do tratamento por próteses totais por meio de radiografias cefalométricas laterais e fotografias

Costa, Carolina Bacci [UNESP] 29 May 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-05-29Bitstream added on 2014-06-13T20:26:07Z : No. of bitstreams: 1 costa_cb_dr_sjc.pdf: 4766898 bytes, checksum: 139609d52feb53bd42763e2aedffc210 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O propósito neste estudo radiográfico e fotográfico foi avaliar razões entre estruturas ósseas e em tecido mole da face de indivíduos edêntulos, antes e depois do tratamento por próteses totais e compará-las à proporção áurea. Os valores de algumas razões também foram correlacionados entre as análises radiográfica e fotográfica. Foram selecionados 54 indivíduos desdentados totais que realizaram o tratamento reabilitador por próteses totais na Faculdade de Odontologia de São José dos Campos-UNESP, durante o período letivo de 2010. Foram obtidas duas radiografias cefalométricas laterais, duas fotografias na norma lateral e duas fotografias na norma frontal de cada indivíduo, sendo a primeira sem as próteses e a segunda com as novas próteses totais em posição. Foram avaliadas 4 razões nas radiografias cefalométricas laterais denominada análise áurea 1-AA1- (Or-Me/Co-Go; Or-Me/Ena-Enp; Or-Me/N-Ena; N-Me-Ena-Me), 5 razões nas fotografias laterais -AA2- (Tr-Me’/Tr-Sn; Tr-Me’/N’-Me’; Tr-Sn/Sn-Me’; Sn-Me’/St-Me’; N’-Sn/St-Me’) e 5 razões nas fotografias frontais -AA3- (Tr-Me’/DN-Me’; DN-Me’/Tr-DN; Tr-PN/PN-Me’; PN-Me’/DN-PN; Ls-Me’/PN-Ls). Realizouse o teste t-pareado para comparar as médias antes e depois do tratamento por próteses totais e o teste t de Student para comparar as médias de cada razão ao número áureo (1,618). As razões das análises AA1, AA2 e AA3 apresentaram diferenças estatisticamente significantes antes e depois do tratamento, com exceção das razões Sn-Me’/St-Me’ e DN-Me’/Tr-DN. As razões Or-Me/Co-Go (depois do tratamento) e Tr- Me’/DN-Me’ (antes do tratamento) foram consideradas estatisticamente iguais ao número áureo. Observou-se correlação estatisticamente significante (p<0,05) somente entre as razões Or-Me/Ena-Enp e Tr- Me’/Tr-Sn, antes e depois... / The aim of this study was to evaluate ratios in the face of edentulous subjects, between bone structures and soft tissue, before and after prosthetic treatment. The ratios were compared to the golden number (1,618) and verified correlations in ratios in x-rays and photographs analysis. Fifty-four edentulous subjects were selected and the complete dentures were made by School of Dentistry`s students, from Unesp – Univ Estadual Paulista. Two lateral cephalometric x-rays, two lateral photographs and two frontal photopraphs of each subject were obtained (the first without the complete dentures, in mandibular rest position, and the second, in occlusion). The ratios evaluate in lateral cephalometric xrays were Or-Me/Co-Go; Or-Me/Ena-Enp; Or-Me/N-Ena; N-Me-Ena-Me; in lateral photographs Tr-Me’/Tr-Sn; Tr-Me’/N’-Me’; Tr-Sn/Sn-Me’; Sn-Me’/St- Me’; N’-Sn/St-Me’ and in frontal photographs Tr-Me’/DN-Me’; DN-Me’/Tr- DN; Tr-PN/PN-Me’; PN-Me’/DN-PN; Ls-Me’/PN-Ls. The means of each ratio were statistically analysed by paired t-test and Student`s t-test, and compared with the golden number 1,618. There were statistically significant in ratios before and after prosthetic treatment, except for the ratios Sn-Me’/St-Me’ and DN-Me’/Tr-DN. The ratios Or-Me/Co-Go (after complete denture) and Tr-Me’/DN-Me’ (before complete denture) were considered statistically equal to the golden number. There was a statistically significant correlation (p <0.05) between the ratios Or-Me/Ena- Enp and Tr-Me'/ Tr-Sn before... (Complete abstract click electronic access below)
28

Avaliação cinesiográfica e da satisfação de usuários de próteses totais após a utilização de dois adesivos

Rodriguez, Larissa Santana [UNESP] 17 December 2014 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-12-17. Added 1 bitstream(s) on 2016-12-09T13:55:27Z : No. of bitstreams: 1 000871149.pdf: 3171374 bytes, checksum: d72bc551442973ddfaca022636b176ce (MD5) / O objetivo deste estudo foi avaliar o efeito da utilização de dois adesivos (AS) (Ultra Corega creme- A1 e Ultra Corega pó - A2) sobre o padrão de movimentos mandibulares, movimentação da prótese total convencional (PT) superior, e o índice de satisfação dos usuários de PT com AS. Material e método: Os participantes (n=40) receberam PT novas e após o período de adaptação, foram submetidos a uma primeira avaliação, e divididos aleatoriamente em dois grupos em função dos protocolos (P): P1- utilização de A1 seguida de utilização de A2; P2 - utilização de A2 seguida de utilização de A1. As variáveis foram obtidas por meio de questionário e cinesiografia. Resultados: Houve uma intrusão semelhante entre controle, A1 e A2 (0,85 mm), porém, um maior deslocamento (0,17 mm) da PT superior após o uso de A2 (p<0,05). Não houve diferença significativa (p>0,05) para o movimento tridimensional da mandíbula após o uso de A1/A2. O conforto e retenção da PT mandibular foram influenciados pelos AS (p< 0,05). A1 e A2 não apresentam diferenças significativas em relação aos seus aspectos (p<0,05), entretanto, quando avaliada a satisfação entre eles, A1 apresentou diferenças significantes em relação a A2 (p<0,05). Conclusão: Embora a utilização de A1 ou A2 não tenha influenciado o movimento tridimensional da mandíbula, foi observado um maior deslocamento da PT superior durante a mastigação com A2. Ambos AS têm influência significativa na satisfação dos pacientes (Resumo completo, clicar acesso eletrônico abaixo) / The objective ofthis studywas toevaluate the effect of using two denture adhesive (DA) (Ultra Corega cream- A1 and Ultra Corega powder - A2) on the pattern of jaw movements, maxillary complete denture (CD) movement, and satisfaction of CD with DA. Methods: Participants (n = 40) received new CD and after the adjustment period, they were submitted an initial assessment, and divided randomly into two groups according to the protocols (P): P1- use A1 followed by use A2; P2 - use A2 followed by use A1. The data were obtained through a questionnaire and kinesiography. Results: There was a similar intrusion of control, A1 and A2 (0.85 mm), but a larger displacement (0.17 mm) from the maxillary CD after use A2 (p <0.05). There was no significant difference (p> 0.05) for the three-dimensional movement of the jaw after using A1 / A2. The comfort and retention of mandibular PT were influenced by AS (p <0.05). A1 and A2 show no significant differences in relation to their aspects (p <0.05), however, when was evaluated the satisfaction between them, A1 showed significant differences from A2 (p <0.05). Conclusion: Although the use of A1 or A2 did not influence the three-dimensional movement of the jaw, a greater displacement of the maxillary CD was observed during chewing with A2. Both DA had significant influence on patient satisfaction, and A1 showed the best results.
29

Estudo comparativo entre dois adesivos no desempenho mastigatório de usuários de próteses totais /

Oliveira Junior, Norberto Martins de. January 2014 (has links)
Orientador: Marco Antonio Compagnoni / Banca: Ana Carolina Pero / Banca: Karin Hemana Neppelenbroek / Resumo: Proposição: O objetivo deste estudo foi avaliar o efeito da utilização de dois adesivos para prótese em relação ao desempenho mastigatório de usuários de próteses totais convencionais, por meio de um estudo "cross-over". Material e Método: Cinquenta indivíduos totalmente desdentados receberam novas próteses totais bimaxilares e, após o período de adaptação posterior à instalação, foram submetidos à análise do desempenho mastigatório com as próteses sem adesivos protéticos (controle). Posteriormente, a amostra foi dividida aleatoriamente e designada a dois protocolos, nos quais a ordem de uso dos adesivos era diferente. Os adesivos Ultra Corega creme e Ultra Corega pó foram utilizados por 15 dias previamente à aplicação de novas análises do desempenho mastigatório, por toda a amostra, e respeitando-se um período de descanso (washout), também de 15 dias, entre o uso de cada adesivo. O desempenho mastigatório foi avaliado pelo método dos tamises. Os dados obtidos foram submetidos ao teste não-paramétrico de Friedman e comparação múltipla de média de ordens utilizando o teste de DUNN (α=0,05). Resultados: Houve aumento significativo do desempenho mastigatório após uso dos adesivos Ultra Corega creme (med=27,4%) e Ultra Corega pó (med=28,0%), quando estes foram comparados ao grupo controle (med=16,5%) (p<0,001; n=30), não havendo diferença estatisticamente significante entre os adesivos testados (p=0,897; n=30). Conclusões: O uso de adesivos aumentou o desempenho mastigatório de usuários de próteses totais convencionais, e não houve diferença para o desempenho mastigatório quanto ao uso de adesivos nas formas de creme e pó. / Abstract: Objective: The objective of this study was evaluate the effect of use of two denture adhesives in relation to masticatory performance of conventional complete denture wearers, by means of a cross-over study. Material and Method: Fifty edentulous individuals received new bimaxillary complete dentures and, after the adaptation period, were submitted to masticatory performance analysis with complete dentures without adhesives (control). So, the sample was randomly divided and assigned to two protocols, in which the adhesives order of use was different. The adhesives Ultra Corega cream and Ultra Corega powder were used for 15 days prior the application of new masticatory performance analysis, by all the sample, and respecting a washout period, also 15 days, between the use of each adhesive. The masticatory performance was evaluated by sieves method. Data were analyzed by nonparametric Friedman test and multiple comparison of average orders using test DUNN (α=.05). Results: There was significant increase in masticatory performance after use of adhesives Ultra Corega cream (med=27.4%) and Ultra Corega powder (med=28.0%), when these were compared to the control group (med=16.5%) (p<.001; n=30), without statistically significant difference between the tested adhesives (p=0,897; n=30). Conclusions: The use of adhesives increased masticatory performance of conventional complete denture wearers, and there was no difference for masticatory performance as the use of adhesives in the forms of cream and powder. / Mestre
30

Avaliação in vitro da influência de cargas axiais em próteses parciais fixas implanto-suportadas, por meio da extensometria /

Vasconcellos, Luis Gustavo Oliveira de . January 2008 (has links)
Orientador: Lafayette Nogueira Junior / Banca: Renato Sussumu Nishioka / Banca: Diego Klee de Vasconcellos / Resumo: O objetivo deste estudo foi avaliar in vitro, por meio da extensometria, a influência da aplicação de cargas axiais em próteses parciais fixas de 3 elementos, suportadas por implantes de conexão hexágono interno (HI), variando o tipo de cilindro e o ponto de aplicação de carga. Inicialmente foram inseridos, em disposição linear, três implantes de HI em um bloco de poliuretano. Em seguida, pilares protéticos microunit foram conectados aos implantes com torque de 20Ncm, e sobre estes foram parafusados cilindros usinados de Co-Cr e cilindros plásticos, as quais receberam enceramentos padronizados que foram posteriormente fundidos em liga de Co-Cr (n=5). Quatro extensômetros (SG) foram colados na superfície do bloco, tangenciando os implantes visando mensurar a microdeformação peri-implantar no momento da aplicação das cargas. Cada estrutura metálica foi parafusada sobre os pilares protéticos com torque de 10Ncm e a seguir foi realizada a aplicação de carga axial de 30kg em 5 pontos pré-determinados. Os dados obtidos na extensometria foram submetidos aos testes estatísticos ANOVA e Tukey (α=5%). Os resultados mostraram diferença estatisticamente significante para o ponto de aplicação de carga (p=0,0001), sendo que o ponto B gerou a menor microdeformação (239,49με) e o ponto D a maior microdeformação (442,77με). Com relação ao tipo de cilindro, não foi observada diferença estatisticamente significante (p=0,748). Concluiu-se que o tipo de cilindro não interferiu na magnitude da microdeformação peri-implantar durante a aplicação de cargas axiais e que a localização da aplicação de carga axial influenciou a magnitude desta microdeformação. / Abstract: The aim of this study was to evaluate in vitro, by means of strain gauge analysis, the influence of aplication of axial loading in three-units fixed partial prostheses, supported by implants with internal hexagon connection (IH), varying the type of cylinders, and the point of load application. Three fixtures IH were inserted in linear arrangement, into a polyurethane block. Microunit abutments were connected to implants with torque of 20Ncm. The framework were fabricated as a one piece casting using plastic burn out components and Co-Cr prefabricated cylinders components (n=5). Four strain gauge were bonded around the microunit abutments on block surface to measure the peri-implant microstrain at the time of application of loads. Each framework was tight on the abutments with torque of 10Ncm and then was made the application of axial load of 30kg in 5 points pre-determined. The data obtained in the strain gauge analysis were submitted to the statistical tests ANOVA and Tukey (α=5%). The results showed a statistically significant difference to the point of application of load (p = 0.0001), whereas the point B has generated the lowest microstrain (239.49 με) and the point D has provided the highest microstrain (442.77 με). Regarding the type of cylinder, statistically significant difference was not observed (p = 0.748). It was concluded that the type of cylinder did not interfere on the magnitude of peri implant microstrain during the application of axial loads and that the location of the application of axial load influenced the magnitude of this microstrain. / Mestre

Page generated in 0.4372 seconds