• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • Tagged with
  • 32
  • 32
  • 29
  • 28
  • 9
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Aplicação de campos elétricos em procedimentos de extração em fase sólida. / Application of electric fields in solid phase extraction procedures

Orlando, Ricardo Mathias 06 March 2011 (has links)
Orientadores: Susanne Rath, Jarbas José Rodrigues Rohwedder / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-19T11:12:21Z (GMT). No. of bitstreams: 1 Orlando_RicardoMathias_D.pdf: 5151319 bytes, checksum: 53a60cd9c94d86b8a9e269a87ef0c9ac (MD5) Previous issue date: 2011 / Resumo: O preparo de amostra representa uma etapa determinante e crítica no processo de análise e a extração em fase sólida (SPE) é uma técnica amplamente empregada no preparo de matrizes complexas. O objetivo deste trabalho foi o desenvolvimento de dispositivos e procedimentos que permitem aplicar campos elétricos em SPE empregando cartuchos (E-SPE®), visando adicionar os mecanismos da eletroforese ao processo cromatográfico. Para tanto, foram desenvolvidos eletrodos e cartuchos que possibilitam a aplicação de campos elétricos, além de um sistema para monitorar e controlar parâmetros eletrocromatográficos tais como: vazão, corrente elétrica, potencial elétrico e temperatura. Com esses dispositivos foram realizadas extrações com aplicação de campo elétrico empregando compostos modelo aniônicos, catiônicos e anfotéricos. Para permitir uma melhor compreensão dos fenômenos envolvidos foram avaliados diversos parâmetros de extração, entre esses: concentração de íons em solução, pH, modificador orgânico, volume de solução de lavagem e tipo de sorvente. O sistema foi avaliado também na determinação de antimicrobianos em leite. Dependendo da polaridade empregada sobre os eletrodos, a aplicação do campo elétrico foi capaz de modular (acelerar ou retardar) a saída dos compostos modelo do cartucho. Os resultados de extração obtidos demonstraram a eficácia dos dispositivos desenvolvidos, além da grande potencialidade do uso de campos elétricos em SPE para obter maiores recuperações dos analitos de interesse e/ou remoção de interferentes / Abstract: Sample preparation is a crucial and determinant step for the analysis process and solid phase extraction (SPE) is a widely used technique in the preparation of complex matrices. The aim of this work was the development of devices and procedures for applying electric fields to SPE cartridges (SPE-E ®), in order to add the mechanisms of electrophoresis to the chromatographic process. For this purpose, electrodes and cartridges that allow the application of electric fields were developed, besides a system to monitor and control electrochromatographic parameters such as: flow, electric current, electric potential and temperature. By means of these devices, extractions with application of electric fields were performed using anionic, cationic and amphoteric model compounds. In order to allow a better understanding of the phenomena involved several extraction parameters were evaluated, among these: the concentration of ions in solution, pH, organic modifier, volume of washing solution and type of sorbent. The system was also evaluated for the determination of antibiotics in milk. Depending on the polarity of the electrodes used, the application of an electric field was able to modulate (accelerate or retard) the output of the model compounds from the cartridge. The extraction results obtained showed the effectiveness of the devices developed, and the immense potential of the use of electric fields in SPE to obtain better recoveries of the analytes and/or for removing interferents / Doutorado / Quimica Analitica / Doutor em Ciências
32

Desenvolvimento de estratégias analíticas visando a determinação de macroelementos, microelementos e elementos traço em rações de cães e gatos empregando técnicas de espectrometria atômica / Development of analytical strategies aiming the determination of macroelementos, microelementos and trace elements in feeds for dogs and cats employing atomic espectrometry techniques

Ávila, Dayara Virgínia Lino 29 February 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this work, four methods were developed for analysis of feed for dogs and cats using atomic spectrometry techniques. Initially, the multivariate optimization of sample digestion procedure was employed in wet feed for dogs and cats and then the simultaneous determination of macroelements (Ca, K, Mg and P), microelements (Cu, Fe, Mn, and Zn) and trace elements (Al, B, Ba and Sr) was carried out by optical emission spectrometry with inductively coupled plasma (ICP OES). The results of the elements concentrations in the samples were in agreement with the values provided and regulated by Ministry of Agriculture, Livestock and Supply (Ministério da Agricultura, Pecuária e Abastecimento - MAPA) and American Association of Official Food Control Officials (AAFCO). Limits of detections (LoD) ranged between 0.1 μg g-1 (Ba, Mg and Sr) and 15.0 μg g-1 (P) and limits of quantification (LoQ) between 0.3 μg g-1 (Ba, Mg and Sr) and 49.9 μg g-1 (P). In the second part of the work two analytical methods were optimized for Co and Cr determination in wet food (sachets and cans) for dogs and cats using direct sample analysis (SS) and detection by high resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS). Pyrolysis temperatures were 1500 ° C and 1400 ° C for Cr and Co determination, respectively. Atomization temperatures of 2500 ° C for Cr, and 2400 ° C for Co with chemical modifiers were adopted. The optimized method for Co and Cr determination in wet feed was fast, precise and accurate and contributes to the concept of “Green Chemistry”. The results obtained for concentrations of Cr and Co were not compared to any official rule, since there is no regulation for these elements. The LoD's obtained for Cr and Co were 0.01 and 0.05 ug g-1, respectively, and LoQ's obtained were 0.03 to 0.17 ug g-1 for Cr and Co, respectively. Finally, in the third part of the work, an analytical method for determination of Zn in dry feed for dogs and cats using energy dispersive Xray fluorescence spectrometry (EDXRF) was developed. Sample were prepared as pressed pellets. The concentration of Zn in seven dry feed samples for dogs and cats were determinate. The results were statistically compared to the values found by the analytical method by ICP OES. Additionally, paired t-test between concentrations of Zn by EDXRF and ICP OES was applied. The LoD e LoQ obtained for Zn determination were 0.1 e 0.4 mg kg-1, respectively. The independent methods were not significantly different at a 95% confidence level. In our work, the analytical methods proposed were efficient, fast and reliable for the determination of macroelements (Ca, Mg, K and P), microelements (Cu, Fe, Mn and Zn) and trace elements (Al, B, Ba, Co, Cr and Sr) in feeds for dogs and cats using atomic spectrometry techniques. This work was financially supported through the project Universal notice nº 014/2013 approved by CNPq, registered process nº 482416 / 2013-0. / Neste trabalho, foram desenvolvidos quatro métodos para análise de rações de cães e gatos, usando técnicas de espectrometria atômica. Primeiramente, foi empregada a otimização multivariada do procedimento de digestão da amostra para determinação simultânea de macroelementos (Ca, K, Mg e P), microelementos (Cu, Fe, Mn e Zn) e elementos traço (Al, B, Ba e Sr) em rações úmidas de cães e gatos, utilizando a espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES). Os resultados das concentrações dos elementos nas rações dos animais mostraram-se de acordo com os valores fornecidos e regulamentados pelo Ministério da Agricultura, Pecuária e Abastecimento (MAPA) e pela Associação Americana de Controle Oficial dos Alimentos (AAFCO). Os LoD’s variaram entre 0,1 μg g-1 (Ba, Mg e Sr) e 15,0 μg g-1 (P) e os LoQ’s variaram entre 0,3 μg g-1 (Ba, Mg e Sr) e 49,9 μg g-1 (P). Na segunda parte do trabalho, foram otimizados dois métodos analíticos para determinação de Co e Cr em rações úmidas (sachês e enlatadas) para cães e gatos utilizando análise direta de sólidos (SS) e detecção por espectrometria de absorção atômica de alta resolução com fonte contínua e atomização em forno de grafite (HR-CS GF AAS). Foram estabelecidas temperaturas de pirólise de 1500°C e de 1400°C para a determinação de Cr e Co respectivamente, e temperaturas de atomização de 2500°C para Cr e de 2400°C para Co, sem o uso de modificadores químicos. Os métodos otimizados foram rápidos, precisos e exatos, além de contribuir com a concepção da Química Verde. Os resultados obtidos para as concentrações de Cr e Co não foram comparados com nenhuma norma, uma vez que estes elementos não são regulamentados. Os LoD’s obtidos para Cr e Co foram de 0,01 e 0,05 μg g-1 respectivamente, já os LoQ’s obtidos para Cr e Co foram de 0,03 a 0,17 μg g-1 respectivamente. Por fim, na terceira parte do trabalho, foi desenvolvido um método analítico para determinação de Zn em rações secas destinadas à alimentação de cães e gatos empregando a espectrometria de fluorescência de raios-X com energia dispersiva (EDXRF). As amostras foram preparadas na forma de pastilhas prensadas e a concentração de Zn, determinada em sete rações secas de cães e gatos. Os resultados obtidos foram estatisticamente comparados com os valores encontrados através de um método analítico estabelecido por ICP OES, em que foi aplicado o teste t pareado entre as concentrações de Zn por EDXRF e ICP OES. Os LoD e LoQ obtidos na determinação de Zn através do método foram de 0,1 e 0,4 mg kg-1 respectivamente. Os métodos independentes não apresentaram diferença significativa para um nível de confiança de 95%. Em nosso trabalho, os métodos analíticos propostos foram eficientes, rápidos, e confiáveis para a determinação de macroelementos (Ca, Mg, K e P), microelementos (Cu, Fe, Mn e Zn) e elementos traço (Al, B, Ba, Co, Cr e Sr) em rações de cães e gatos, usando técnicas espectroanalíticas. Este trabalho teve o auxílio financeiro do projeto Universal Edital 014/2013 aprovado pelo CNPq, registrado sob processo nº 482416/2013-0.

Page generated in 0.0826 seconds