• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • Tagged with
  • 10
  • 10
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Método inovador de ativação de oxidantes no tratamento de poluentes prioritários e emergentes. / Innovative method of oxidants activation in the treatment of emerging and priority pollutants.

Silva, Celyna Káritas Oliveira da 24 October 2014 (has links)
O presente trabalho trata do desenvolvimento um novo material, diatomita modificada por ferro, como ativador dos oxidantes persulfato de sódio e peróxido de hidrogênio para degradar poluentes prioritários (fenantreno e antraceno), diesel e o poluente emergente ácido perfluoroctanóico (PFOA). Os objetivos deste estudo foram comparar esse novo método com métodos convencionais de ativação para esses oxidantes; e estudar, estatisticamente, a relação ótima entre a quantidade deste material e a concentração de oxidante para a degradação dos contaminantes. A diatomita bruta e as diatomitas modificadas (CAT-5 e CAT-20) foram caracterizadas por diferentes técnicas. Os principais resultados da caracterização mostraram que os materiais são amorfos e que a concentração de ferro foi 4%, 17% e 25% para diatomita bruta, CAT-5 e CAT-20, respectivamente. Os resultados mostraram que os materiais modificados apresentaram significativa atividade catalítica para ativar os oxidantes e degradar os poluentes, sendo a CAT-5 a mais reativa. Resultados satisfatórios foram obtidos utilizando 45 g L-1 de persulfato de sódio com 2,5 g de diatomita modificada (CAT-5), com degradação de 87% e 96% de fenantreno e antraceno, respectivamente, em 168 horas de tratamento. Para o tratamento de solo arenoso contaminado com diesel, os melhores resultados foram obtidos utilizando 41 g L-1 de persulfato de sódio e 1,56 g de CAT-5, obtendo decaimento de 91% de carbono total em 146 horas. A eficiência da decomposição de PFOA mostra que a reatividade dos sistemas seguiu a ordem: peróxido de hidrogênio em altas concentrações > peróxido de hidrogênio em paralelo com persulfato > persulfato alcalino, ambos ativados com CAT-5, atingindo 86%, 69% e 48%, respectivamente, após 6 horas de reação. / The present work deals with the development of a new materials, modified diatomite by iron, as an activator of the oxidants sodium persulfate and hydrogen peroxide to degrade priority pollutants (phenantherene and anthracene), diesel and emerging pollutant perfluorooctanoic acid (PFOA). The aims of this study were to compare this new method with traditional activation method for these oxidants; and to study, statistically, the optimal ratio between the quantity of the material and the concentration of oxidant to the degradation of contaminants. The raw and modified materials were characterized by different techniques. The main characterization results showed that materials are amorphous, and that the iron concentrations were 4,78%, 17,65% and 25% for the raw diatomite, CAT-5 and CAT-20, respectively. The results showed that the modified material showed significant catalytic activity to activate the oxidants and to degrade pollutants, with CAT-5 being the most reactive. Satisfactory results were obtained using 2,5 g of modified diatomite (CAT-%) with sodium persulfate at 45 g L-1, with degradation of 87% and 96% of phenanthrene and anthracene, respectively, in 168 hours of treatment. For the treatment of sandy soil contaminated with diesel, the best result was obtained using 41 g L-1 of sodium persulfate sodium and 1,56 g of CAT-5, resulting in a decrease of 91% of total carbon present in diesel. The PFOA decomposition efficiency for the systems shows that hydrogen peroxide at high concentrations > hydrogen peroxide-activated persulfate > alkaline-activated persulfate, both with CAT-5, achieving 83%, 69% and 48% , respectively, after 6 hours of reaction.
2

Método inovador de ativação de oxidantes no tratamento de poluentes prioritários e emergentes. / Innovative method of oxidants activation in the treatment of emerging and priority pollutants.

Celyna Káritas Oliveira da Silva 24 October 2014 (has links)
O presente trabalho trata do desenvolvimento um novo material, diatomita modificada por ferro, como ativador dos oxidantes persulfato de sódio e peróxido de hidrogênio para degradar poluentes prioritários (fenantreno e antraceno), diesel e o poluente emergente ácido perfluoroctanóico (PFOA). Os objetivos deste estudo foram comparar esse novo método com métodos convencionais de ativação para esses oxidantes; e estudar, estatisticamente, a relação ótima entre a quantidade deste material e a concentração de oxidante para a degradação dos contaminantes. A diatomita bruta e as diatomitas modificadas (CAT-5 e CAT-20) foram caracterizadas por diferentes técnicas. Os principais resultados da caracterização mostraram que os materiais são amorfos e que a concentração de ferro foi 4%, 17% e 25% para diatomita bruta, CAT-5 e CAT-20, respectivamente. Os resultados mostraram que os materiais modificados apresentaram significativa atividade catalítica para ativar os oxidantes e degradar os poluentes, sendo a CAT-5 a mais reativa. Resultados satisfatórios foram obtidos utilizando 45 g L-1 de persulfato de sódio com 2,5 g de diatomita modificada (CAT-5), com degradação de 87% e 96% de fenantreno e antraceno, respectivamente, em 168 horas de tratamento. Para o tratamento de solo arenoso contaminado com diesel, os melhores resultados foram obtidos utilizando 41 g L-1 de persulfato de sódio e 1,56 g de CAT-5, obtendo decaimento de 91% de carbono total em 146 horas. A eficiência da decomposição de PFOA mostra que a reatividade dos sistemas seguiu a ordem: peróxido de hidrogênio em altas concentrações > peróxido de hidrogênio em paralelo com persulfato > persulfato alcalino, ambos ativados com CAT-5, atingindo 86%, 69% e 48%, respectivamente, após 6 horas de reação. / The present work deals with the development of a new materials, modified diatomite by iron, as an activator of the oxidants sodium persulfate and hydrogen peroxide to degrade priority pollutants (phenantherene and anthracene), diesel and emerging pollutant perfluorooctanoic acid (PFOA). The aims of this study were to compare this new method with traditional activation method for these oxidants; and to study, statistically, the optimal ratio between the quantity of the material and the concentration of oxidant to the degradation of contaminants. The raw and modified materials were characterized by different techniques. The main characterization results showed that materials are amorphous, and that the iron concentrations were 4,78%, 17,65% and 25% for the raw diatomite, CAT-5 and CAT-20, respectively. The results showed that the modified material showed significant catalytic activity to activate the oxidants and to degrade pollutants, with CAT-5 being the most reactive. Satisfactory results were obtained using 2,5 g of modified diatomite (CAT-%) with sodium persulfate at 45 g L-1, with degradation of 87% and 96% of phenanthrene and anthracene, respectively, in 168 hours of treatment. For the treatment of sandy soil contaminated with diesel, the best result was obtained using 41 g L-1 of sodium persulfate sodium and 1,56 g of CAT-5, resulting in a decrease of 91% of total carbon present in diesel. The PFOA decomposition efficiency for the systems shows that hydrogen peroxide at high concentrations > hydrogen peroxide-activated persulfate > alkaline-activated persulfate, both with CAT-5, achieving 83%, 69% and 48% , respectively, after 6 hours of reaction.
3

Resistência aos compostos de amônio quaternário (QACs) de uso doméstico e hospitalar em patógenos prioritários multirresistentes / Resistance to quaternary ammonium compounds (QACs) for domestic and hospital use in multiresistant priority pathogens

Espinoza Muñoz, Maria Elena 10 May 2019 (has links)
Compostos de amônio quaternário (QACs) têm sido amplamente utilizados como desinfetantes e antissépticos, sendo essenciais na prevenção e controle de infecções bacterianas na medicina humana e veterinária. Embora patógenos prioritários multirresistentes têm sido muito bem caracterizados quanto ao perfil de suscetibilidade e contexto genético da resistência aos antibióticos, dados de resistência aos QACs são limitados. Assim, o objetivo do presente estudo foi avaliar a atividade in vitro dos QACs de uso doméstico e hospitalar [cloreto de benzalcônio (BAC), cloreto de cetilpiridinio (CPC) e brometo de cetiltrimetilamônio (CTAB)], contra patógenos prioritários multirresistentes, identificando os principais genes de resistência associados. Foram estudadas 100 cepas multirresistentes previamente sequenciados usando as plataformas Illumina MiSeq e NextSeq representativas de diferentes hospedeiros (humanos e animais) e fontes (ambientes e alimentos). As cepas foram identificadas como Klebsiella pneumoniae (n= 24), Escherichia coli (n= 30); Pseudomonas aeruginosa (n= 10), Enterobacter spp, (n= 8), Acinetobacter baumannii (n= 11) e Salmonella spp. (n= 17). Genes de resistência aos QACs foram identificados in silico através do alinhamento dos contigs obtidos de cada cepa sequenciada com genes de referência obtidos do GenBank, utilizando o programa Geneious versão 8 (Biomatters Ltd). A identidade de cada gene foi analisada utilizando o programa BLASTx, no qual um critério baseado em ≥90% identidade resultou na identificação dos genes mdfA (77%), qacE (44%), qacEΔ1 (43%), sugE(c) (29%), emrE (21%), qacA (19%), sugE(p) (5%), qacF (7%), qacH (7%) e qacL (7%) em 85 cepas; enquanto que 15 cepas não possuíam nenhum gene de resistência aos QACs. A concentração inibitória mínima (CIM) dos QACs para as 100 cepas foi determinada pelo método de microdiluição em caldo. Os resultados sugeriram que a resistência em patógenos prioritários circulando na interface humano-ambiente-animal não é restrita aos antibióticos, uma vez que a elevada ocorrência de genes qacE, qacEΔ1 e mdfA poderia estar associada com uma redução da suscetibilidade para QACs. Consequentemente, a resistência aos QACs poderia também contribuir para a persistência e adaptação destes patógenos nos seres humanos e outros animais, assim como em ambientes impactados antropogenicamente. / Quaternary ammonium compounds (QACs) have been widely used as disinfectants and antiseptics, being applied as essential compounds in the prevention and control of bacterial infections in human-and veterinary hospital medicine. Although multiresistant priority pathogens have been well characterized with respect to their susceptibility profile and their genetic context of resistance for antibiotics, studies of resistance to QACs are limited. Thus, the objective of the present study was to evaluate the in vitro activity of QACs [(benzalkonium chloride (BAC), cetylpyridinium chloride (CPC) and cetyltrimethylammonium bromide (CTAB)] for household and hospital use against multiresistant priority pathogens, identifying the main resistance genes associated. A hundred multiresistant isolates (previously sequenced using the Illumina MiSeq and NextSeq platforms), representative of different hosts (humans and animals) and sources (environment and food) were studied. Isolates were identified as Klebsiella pneumoniae (n=24), Escherichia coli (n=30), Pseudomonas aeruginosa (n=10), Enterobacter spp. (n=8), Acinetobacter baumannii (n=11) and Salmonella spp. (n=17). In silico analysis for identification of genes conferring resistance to QACs were performed by aligning the contigs obtained from the strains with reference genes deposited in GenBank, using the Geneious version program (Biomatters Ltd). Similarities were analyzed using the BLASTx online program, considering the alignment criteria based on ≥ 90% identity. The result of these analysis revealed the presence of the following QAC genes: mdfA (77%), qacE (44%), qacEΔ1 (43%), sugE(c) (29%), emrE (21%), qacA (19%), sugE (p) (5%), qacF (7%), qacH (7%) e qacL (7%); while 15 strains showed no resistance genes for QACs. Determination of QACs minimum inhibitory concentration (MIC) for the 100 isolates, by the broth microdilution method. These results suggest that resistance to QACs in priority pathogens, circulating at the human-environment-animal interface, is not restricted to antibiotics, since the high occurrence of genes qacE, qacEΔ1 and mdfA were associated with a reduced susceptibility to QACs. Consequently, resistance to QACs could also contribute to the persistence and adaptation of these pathogens in humans and othes animals, as well as in anthropogenically impacted environments.
4

Instrumentos financeiros patrimoniais previstos na legislação societária brasileira à luz das normas internacionais de contabilidade / Equity financial instruments as per the Brazilian corporate law in the light of the international financial reporting standards

Ferreira, Tadeu Cendon 28 July 2016 (has links)
Desde a adoção das normas internacionais de relatórios financeiros (IFRS) no Brasil, em 2010, a discussão sobre a classificação de instrumentos financeiros entre instrumentos de dívida ou de patrimônio tem se intensificado. Quando a Lei 11.638/07 foi emitida, alterando a Lei das Sociedades por Ações de 1976, teve o condão de introduzir o padrão contábil internacional na contabilidade brasileira. Entretanto, muitos dos instrumentos e aspectos da legislação societária brasileira não foram alterados ou reavaliados à luz desse novo padrão. De um momento para o outro, empresas se viram obrigadas a classificar como dívida, valores antes classificados com patrimônio líquido, como foram os diversos casos de ações resgatáveis. A própria classificação das ações ordinárias e preferenciais como instrumentos de patrimônio líquido foi colocada em dúvida devido à previsão do chamado dividendo mínimo obrigatório. Nesse ínterim, companhias abertas brasileiras emitiram certos instrumentos financeiros, analisaram e os classificaram como instrumentos de patrimônio líquido. Entretanto, tiveram tal classificação questionada pela CVM e foram requeridas a refazer suas demonstrações financeiras. Mesmo internacionalmente essa classificação não é, muitas vezes, óbvia. As últimas discussões no âmbito internacional relacionados com a classificação de instrumentos financeiros como de dívida ou de patrimônio se concentraram em duas abordagens: a \"abordagem restrita do patrimônio líquido\" (Narrow Equity Approach) e a \"abordagem estrita do passivo\" (Strict Obligation Approach). Este trabalho tem como objetivo avaliar a classificação dos instrumentos financeiros patrimoniais previstos na legislação societária brasileira à luz das normas internacionais de relatórios financeiros. Primeiramente entendendo e avaliando os casos de determinação da CVM de refazimento das demonstrações financeiras de companhias em virtude de classificação considerada inadequada de certos instrumentos financeiros como de patrimônio líquido. Em seguida, avaliando a natureza dos instrumentos patrimoniais previstos na legislação societária brasileira, especialmente as ações com dividendos prioritários, e o impacto dessa prioridade nas demonstrações financeiras das companhias. Com base nos resultados do estudo, concluiu-se que os casos de refazimento estavam relacionados a uma tentativa de classificar instrumentos típicos de dívida como patrimoniais, a partir da alteração de certos termos, mas sem atender a todos os requisitos da norma contábil. Adicionalmente, para as companhias com ações preferenciais com dividendos prioritários, observamos que os instrumentos atendiam a classificação de patrimônio líquido e que a prioridade no recebimento trouxe benefícios de fato para os seus detentores. / Since the adoption of the International Financial Reporting Standards in Brazil, in 2010, the discussion on the classification of financial instruments between debt or equity instruments has intensified. When the law 11,638/07 was issued, changing the Brazilian Corporate Law of 1976, had the effect of introducing international accounting standards in the Brazilian accounting environment. However, many of the instruments and aspects of Brazilian corporate legislation have not changed or reassessed in the light of this new standard. From one moment to the next, companies were required to reclassify amounts from equity to debt, as were the various cases of redeemable shares. Even the classification of ordinary and preferred shares as equity instruments was questioned due to the statutory minimum mandatory dividend. In the meantime, Brazilian listed companies have issued certain financial instruments, analyzed and classified them as equity instruments. However, they had such a classification questioned by the Brazilian Securities and Exchange Comission (CVM) and were required to restate their financial statements. Even internationally, this classification is not often obvious. The latest discussions in the international forum related to the classification of financial instruments as debt or equity focused on two approaches: the Narrow Equity Approach and the Strict Obligation Approach. This study aims to evaluate the classification of equity financial instruments as per the Brazilian corporate legislation in light of the International Financial Reporting Standards. Firstly, understanding and evaluating the cases of restatement of the financial statements of companies as determined by CVM due to misclassification of certain financial instruments as equity. Then, assessing the nature of equity instruments as per the Brazilian corporate legislation, especially the shares with priority dividends, and the impact of this priority in the financial statements of the company. Based on the results of the study, it was concluded that the restatements were related to the attempt of classifying typical debt instruments as equity, by amending certain of their terms, but not meeting all the requirements of the relevant accounting standard. Additionally, for companies with preferred shares with priority dividends, we observed that the instruments were classified as equity and that the priority has effectively brought benefits to these shareholders.
5

Efetividade do tratamento supervisionado para a Tuberculose em cinco Unidades Federadas no Brasil.

Abreu, Ricardo Gadelha de January 2007 (has links)
p. 1-38 / Submitted by Santiago Fabio (fabio.ssantiago@hotmail.com) on 2013-04-23T20:37:59Z No. of bitstreams: 1 44444444.pdf: 639088 bytes, checksum: 4e30ebf9edb1a60e107b4e1461e251d6 (MD5) / Approved for entry into archive by Maria Creuza Silva(mariakreuza@yahoo.com.br) on 2013-05-04T17:32:06Z (GMT) No. of bitstreams: 1 44444444.pdf: 639088 bytes, checksum: 4e30ebf9edb1a60e107b4e1461e251d6 (MD5) / Made available in DSpace on 2013-05-04T17:32:06Z (GMT). No. of bitstreams: 1 44444444.pdf: 639088 bytes, checksum: 4e30ebf9edb1a60e107b4e1461e251d6 (MD5) Previous issue date: 2007 / OBJETIVO: Verificar a efetividade da estratégia DOTS para tuberculose e os percentuais de cura e de abandono em municípios brasileiros, além de comparar as coberturas do Programa Saúde da Família (PSF) e os percentuais de cura e de abandono nos municípios prioritários. MÉTODOS: Estudo ecológico exploratório de agregado espacial, em 114 municípios prioritários para tuberculose em 2004 e 109 em 2005 nos estados do Amazonas, Mato Grosso, Pernambuco, Rio Grande do Sul e São Paulo, utilizando-se dados da coorte de casos de tuberculose. RESULTADOS: Porto Alegre apresentou nos dois anos o menor percentual de Unidades de Saúde com Programa de Controle da Tuberculose e DOTS implantados e menor cobertura do Programa Saúde da Família, contudo não foi a capital com menores percentuais de cura no mesmo período. Da mesma forma, os municípios do Rio Grande do Sul foram os com menores coberturas DOTS, mas não necessariamente os com menores proporções de cura e de abandono quando comparados aos das outras Unidades Federadas do estudo. Cuiabá foi a capital com maiores coberturas DOTS, maiores percentuais de cura e menores de abandono. Nenhuma das capitais atingiu os 85% de cura e 5% de abandono preconizados pelo Ministério da Saúde. A mediana da cura entre os municípios selecionados no período variou em 2005, de 63,6% em Pernambuco a 81,7% no Amazonas, em 2004. O valor mediano da proporção de abandono variou de 5,7 em São Paulo, 2005 a 11,5% em Mato Grosso, 2004. As menores coberturas do Programa Saúde da Família foram no Rio Grande do Sul. CONCLUSÕES: Neste estudo, os maiores percentuais de cura e os menores de abandono não estão associados à estratégia DOTS. / Salvador
6

Instrumentos financeiros patrimoniais previstos na legislação societária brasileira à luz das normas internacionais de contabilidade / Equity financial instruments as per the Brazilian corporate law in the light of the international financial reporting standards

Tadeu Cendon Ferreira 28 July 2016 (has links)
Desde a adoção das normas internacionais de relatórios financeiros (IFRS) no Brasil, em 2010, a discussão sobre a classificação de instrumentos financeiros entre instrumentos de dívida ou de patrimônio tem se intensificado. Quando a Lei 11.638/07 foi emitida, alterando a Lei das Sociedades por Ações de 1976, teve o condão de introduzir o padrão contábil internacional na contabilidade brasileira. Entretanto, muitos dos instrumentos e aspectos da legislação societária brasileira não foram alterados ou reavaliados à luz desse novo padrão. De um momento para o outro, empresas se viram obrigadas a classificar como dívida, valores antes classificados com patrimônio líquido, como foram os diversos casos de ações resgatáveis. A própria classificação das ações ordinárias e preferenciais como instrumentos de patrimônio líquido foi colocada em dúvida devido à previsão do chamado dividendo mínimo obrigatório. Nesse ínterim, companhias abertas brasileiras emitiram certos instrumentos financeiros, analisaram e os classificaram como instrumentos de patrimônio líquido. Entretanto, tiveram tal classificação questionada pela CVM e foram requeridas a refazer suas demonstrações financeiras. Mesmo internacionalmente essa classificação não é, muitas vezes, óbvia. As últimas discussões no âmbito internacional relacionados com a classificação de instrumentos financeiros como de dívida ou de patrimônio se concentraram em duas abordagens: a \"abordagem restrita do patrimônio líquido\" (Narrow Equity Approach) e a \"abordagem estrita do passivo\" (Strict Obligation Approach). Este trabalho tem como objetivo avaliar a classificação dos instrumentos financeiros patrimoniais previstos na legislação societária brasileira à luz das normas internacionais de relatórios financeiros. Primeiramente entendendo e avaliando os casos de determinação da CVM de refazimento das demonstrações financeiras de companhias em virtude de classificação considerada inadequada de certos instrumentos financeiros como de patrimônio líquido. Em seguida, avaliando a natureza dos instrumentos patrimoniais previstos na legislação societária brasileira, especialmente as ações com dividendos prioritários, e o impacto dessa prioridade nas demonstrações financeiras das companhias. Com base nos resultados do estudo, concluiu-se que os casos de refazimento estavam relacionados a uma tentativa de classificar instrumentos típicos de dívida como patrimoniais, a partir da alteração de certos termos, mas sem atender a todos os requisitos da norma contábil. Adicionalmente, para as companhias com ações preferenciais com dividendos prioritários, observamos que os instrumentos atendiam a classificação de patrimônio líquido e que a prioridade no recebimento trouxe benefícios de fato para os seus detentores. / Since the adoption of the International Financial Reporting Standards in Brazil, in 2010, the discussion on the classification of financial instruments between debt or equity instruments has intensified. When the law 11,638/07 was issued, changing the Brazilian Corporate Law of 1976, had the effect of introducing international accounting standards in the Brazilian accounting environment. However, many of the instruments and aspects of Brazilian corporate legislation have not changed or reassessed in the light of this new standard. From one moment to the next, companies were required to reclassify amounts from equity to debt, as were the various cases of redeemable shares. Even the classification of ordinary and preferred shares as equity instruments was questioned due to the statutory minimum mandatory dividend. In the meantime, Brazilian listed companies have issued certain financial instruments, analyzed and classified them as equity instruments. However, they had such a classification questioned by the Brazilian Securities and Exchange Comission (CVM) and were required to restate their financial statements. Even internationally, this classification is not often obvious. The latest discussions in the international forum related to the classification of financial instruments as debt or equity focused on two approaches: the Narrow Equity Approach and the Strict Obligation Approach. This study aims to evaluate the classification of equity financial instruments as per the Brazilian corporate legislation in light of the International Financial Reporting Standards. Firstly, understanding and evaluating the cases of restatement of the financial statements of companies as determined by CVM due to misclassification of certain financial instruments as equity. Then, assessing the nature of equity instruments as per the Brazilian corporate legislation, especially the shares with priority dividends, and the impact of this priority in the financial statements of the company. Based on the results of the study, it was concluded that the restatements were related to the attempt of classifying typical debt instruments as equity, by amending certain of their terms, but not meeting all the requirements of the relevant accounting standard. Additionally, for companies with preferred shares with priority dividends, we observed that the instruments were classified as equity and that the priority has effectively brought benefits to these shareholders.
7

Tratabilidade de águas residuárias contendo poluentes perigosos: estudo de caso. / Treatability of hazardous industrial wastewater: case study.

Morita, Dione Mari 29 September 1993 (has links)
O trabalho foi desenvolvido com o objetivo de caracterizar e estudar formas de tratamento de águas residuárias de indústrias de refino de óleo lubrificante e de recuperação de solventes. A fase preliminar teve por objetivo avaliar a biodegradabilidade do despejo combinado dessas duas indústrias. A segunda foi realizada em instalação piloto composta, basicamente, de uma unidade de arraste com ar/tanque de equalização, tanques de correção de pH e de aeração com tempos de detenção distintos, seguidos de tanques de sedimentação. Foram executados testes para avaliar a remoção de material solúvel em n-hexano do despejo da indústria de refino de óleo lubrificante e do efluente final. A unidade de arraste com ar difuso operando com subpressão de 15 mmhg a saída dos gases, vazão específica de ar de 20 ml/l min. E tempo de detenção de 5 dias foi eficiente na remoção de acetona, piridina, benzeno, tolueno, hexano, metil etil cetona e provavelmente solventes clorados. Não apresentou remoção significativa de álcoois, que foram eficientemente degradados no sistema biológico subsequente. Obteve-se remoções superiores a 90%, em termos de dbo e dqo, no processo biológico com tempos de detenção de 20 e 30 dias, e em torno de 80% para os demais. Os sistemas biológicos responderam bem as cargas transientes de solventes, exceto para o tolueno e o álcool isopropílico. / Traditionally, raw materials from solvent recovery and from reclaimed lubricating oil industries are considered hazardous solid waste. Consequently, the best control technology is incineration. This work was developed in order to characterize and to study ways of treating wastewaters from lubricating oil refinery and solvent recovery industries. The experimental part was divided in two phases. The preliminar step aimed to evaluate the biodegradability of combined wastewater from both industries. The second phase was basically carried out in a pilot plant composed by an air stripping unit/equalization tank, pH correction tanks and bioreactors with different retention times, followed by sedimentation tanks. Other than these assays, tests were performed to evaluate the removal of soluble material in n-hexane of the wastewater of the lubricating oil refinery industry and of the supernatant of the sedimentation tank after the bioreactor of 20 days retention.The buble aeration unit operating with a 15 mmHg suppresion to the gas exit, with a specific air flow of 20 mL/L.min. and with a retention time of 5 days was efficient to remove acetone, pyridine, benzene, toluene, hexane, methyl ethyl ketone and probably chlorinated solvents. There was no significative removal of alcohols, that were efficiently degraded in the subsequent biological system. BOD and COD removal efficiencies were better than 90% in the biological process with retention times of 20 and 30 days, and about 80% for the rest. The responses of biological systems to the transient inputs of solvents were well, except for toluene and isopropilic alcohol. Several physico-chemical processes for soluble material in n-hexane removal were studied. The only one to present effluent concentration under the legal limit was the addition of the sodium xylene-sulphonate base demulsifier to the supernatant of the sedimentation tank the bioreactor of 20 days retention.
8

Tratabilidade de águas residuárias contendo poluentes perigosos: estudo de caso. / Treatability of hazardous industrial wastewater: case study.

Dione Mari Morita 29 September 1993 (has links)
O trabalho foi desenvolvido com o objetivo de caracterizar e estudar formas de tratamento de águas residuárias de indústrias de refino de óleo lubrificante e de recuperação de solventes. A fase preliminar teve por objetivo avaliar a biodegradabilidade do despejo combinado dessas duas indústrias. A segunda foi realizada em instalação piloto composta, basicamente, de uma unidade de arraste com ar/tanque de equalização, tanques de correção de pH e de aeração com tempos de detenção distintos, seguidos de tanques de sedimentação. Foram executados testes para avaliar a remoção de material solúvel em n-hexano do despejo da indústria de refino de óleo lubrificante e do efluente final. A unidade de arraste com ar difuso operando com subpressão de 15 mmhg a saída dos gases, vazão específica de ar de 20 ml/l min. E tempo de detenção de 5 dias foi eficiente na remoção de acetona, piridina, benzeno, tolueno, hexano, metil etil cetona e provavelmente solventes clorados. Não apresentou remoção significativa de álcoois, que foram eficientemente degradados no sistema biológico subsequente. Obteve-se remoções superiores a 90%, em termos de dbo e dqo, no processo biológico com tempos de detenção de 20 e 30 dias, e em torno de 80% para os demais. Os sistemas biológicos responderam bem as cargas transientes de solventes, exceto para o tolueno e o álcool isopropílico. / Traditionally, raw materials from solvent recovery and from reclaimed lubricating oil industries are considered hazardous solid waste. Consequently, the best control technology is incineration. This work was developed in order to characterize and to study ways of treating wastewaters from lubricating oil refinery and solvent recovery industries. The experimental part was divided in two phases. The preliminar step aimed to evaluate the biodegradability of combined wastewater from both industries. The second phase was basically carried out in a pilot plant composed by an air stripping unit/equalization tank, pH correction tanks and bioreactors with different retention times, followed by sedimentation tanks. Other than these assays, tests were performed to evaluate the removal of soluble material in n-hexane of the wastewater of the lubricating oil refinery industry and of the supernatant of the sedimentation tank after the bioreactor of 20 days retention.The buble aeration unit operating with a 15 mmHg suppresion to the gas exit, with a specific air flow of 20 mL/L.min. and with a retention time of 5 days was efficient to remove acetone, pyridine, benzene, toluene, hexane, methyl ethyl ketone and probably chlorinated solvents. There was no significative removal of alcohols, that were efficiently degraded in the subsequent biological system. BOD and COD removal efficiencies were better than 90% in the biological process with retention times of 20 and 30 days, and about 80% for the rest. The responses of biological systems to the transient inputs of solvents were well, except for toluene and isopropilic alcohol. Several physico-chemical processes for soluble material in n-hexane removal were studied. The only one to present effluent concentration under the legal limit was the addition of the sodium xylene-sulphonate base demulsifier to the supernatant of the sedimentation tank the bioreactor of 20 days retention.
9

Restabelecimento de energia em sistemas de distribuição considerando aspectos práticos / Distribution systems service restoration with the consideration of practical aspects

Marques, Leandro Tolomeu 13 June 2018 (has links)
No contexto da operação de sistemas de distribuição, um dos problemas com os quais os operadores lidam frequentemente é o de restabelecimento de energia. Este problema surge na ocorrência de uma falta permanente e pode ser tratado por meio de manobras em chaves presentes na rede primária. Uma vez que tais redes operam com topologia radial, a ocorrência de uma falta pode resultar no desligamento de consumidores saudáveis. Desta maneira, o problema consiste em definir, num curto intervalo de tempo, um número mínimo de chaves que devem ser operadas a fim de isolar a falta e restaurar o máximo de consumidores saudáveis desligados. Os esforços para a obtenção de ferramentas computacionais para fornecimento de soluções para o problema de restabelecimento têm sido intensificados nos últimos anos. Isto ocorre, em especial, devido aos enormes prejuízos causados pela falta de energia às companhias de eletricidade e a toda a sociedade. Neste sentido, o objetivo deste trabalho é a obtenção de um método para auxiliar o trabalho dos operadores através do fornecimento de planos adequados de restabelecimento em curtos intervalos de tempo. Os diferenciais deste método proposto são a sua capacidade de: lidar, em especial, com redes reais de grande porte com reduzido esforço computacional; considerar a existência de vários níveis de prioridade de atendimento entre os consumidores (note, por exemplo, que um hospital ou um centro de segurança pública devem ter maior prioridade de atendimento que um grande supermercado ou unidades residenciais) e priorizar o atendimento deles de acordo a sua prioridade; fornecer uma sequência por meio da qual as chaves possam ser operadas a fim de isolar os setores em falta e reconectar o maior número de consumidores saudáveis desligados executando-se o mínimo de manobras em chaves e priorizando os consumidores com maior prioridade; ser capaz de selecionar cargas menos prioritárias para permaneceram desligadas nas situações em que não é possível obter uma solução que restaure todas as cargas saudáveis fora de serviço; e, adicionalmente, priorizar a operação de chaves controladas remotamente, que, diferentemente das chaves controladas manualmente, podem ser operadas com menores custos e de maneira mais rápida. O método proposto consiste, de maneira sintética, na união de uma busca exaustiva aplicada localmente a um novo algoritmo evolutivo multi-objetivo em tabelas de subpopulação que faz uso de uma estrutura de dados eficiente denominada Representação Nó-Profundidade. Para avaliar a performance relativa do método proposto, simulações foram realizadas num sistema de distribuição de pequeno porte e os resultados foram comparados com os obtidos por um método de Programação Matemática. Na sequência, novos experimentos foram realizadas em diversos casos de falta na rede de distribuição da cidade de Londrina-PR e cidades adjacentes. As soluções fornecidas mostraram-se adequadas ao tratamento dos casos de falta, assim como as sequências de chaveamento associadas a elas, as quais foram capazes de priorizar o restabelecimento dos consumidores prioritários seguindo seus níveis de prioridade. Adicionalmente, estudos avaliaram a variação do tempo de processamento computacional do método proposto com a dimensão das redes de distribuições e também com o número de gerações realizadas pelo algoritmo evolutivo multi-objetivo proposto e os resultados mostraram-se satisfatórios às necessidades do problema Portanto, pode-se comprovar que o método proposto atingiu os objetivos especificados, em especial, o tratamento de aspectos práticos do problema. Além do próprio método proposto, algumas contribuições desta pesquisa são a proposição um novo algoritmo evolutivo multiobjetivo em tabelas de subpopulação e de um novo operador para manipulação de florestas de grafo armazenadas pela Representação Nó-Profundidade e voltado ao problema de restabelecimento. / In the context of distribution systems operation, service restoration is one of the problems with which operators constantly deal. It arises when a permanent fault occurs and is treated trough operations in switches at primary grid. Since distribution systems are usually radial, fault occurrence turns-off healthy customers. Thereby, the service restoration problem consists in defining, in a short processing time, the minimum amount of switches that must be operated for the isolation of the fault and reconnection of the maximum amount of healthy out-of-service customers. The efforts of developing computational tools for getting solution to this problems has increased in the last years. It is, in special, due to enormous losses caused to the utilities and to the whole society. In this sense, the main objective of this research is getting a method able to help the distribution system operator\'s work through providing service restoration plans quickly. The differentials of this research are its ability to: deal, in special, with large scale grids whit a reduced computational effort; consider costumers of several priority levels (note, for instance, a hospital has a higher supply priority in relation to a big supermarket) and prioritize the higher priority customers; provide a switching sequence able to isolate and reconnect the maximum amount of healthy out-of-service customer by the minimum amount of switching actions; select lower priority customers to keep out-of-service in order to reconnect higher priority customers when a it is not possible to restore all customers; and, additionally, prioritize switching operation in remotely controlled switches, whose operation is faster and cheapest than the operation of manually controlled switches. The proposed method mixes a local exhaustive search and a new multi-objective evolutionary algorithm in subpopulation tables that uses a data structure named Node-Depth Encoding. For evaluating the relative performance of proposed method, simulations were performed in small distribution systems and the performance was compared with the performance a Mathematical Programing method from literature. New experiments were performed a Mathematical Programing method from literature. New experiments were performed in several fault situations in the real and large-scale distribution system of Londrina-PR and adjacent cities. The solutions provided were appropriated to the treatment of such contingency situations. The same occurs with the switching sequences provided, which were able to prioritize the restoration of higher priority customers. Additional studies evaluated the variation of the running time with the size of grids and with the values adopted for the maximum number of generations of the evolutionary algorithm (which is an input parameter). The results expressed the running time of the proposed method is suitable to the problem needs. Therefore, it could be proved the proposed method achieved the specified objectives, in special, the treatment of practical aspects of the problem. Besides the proposed method, some contributions of this research are proposition of a new multi-objective evolutionary algorithm in subpopulation tables and a new reproduction operator to manipulate graph forests computationally represented by Node-Depth Encoding.
10

Restabelecimento de energia em sistemas de distribuição considerando aspectos práticos / Distribution systems service restoration with the consideration of practical aspects

Leandro Tolomeu Marques 13 June 2018 (has links)
No contexto da operação de sistemas de distribuição, um dos problemas com os quais os operadores lidam frequentemente é o de restabelecimento de energia. Este problema surge na ocorrência de uma falta permanente e pode ser tratado por meio de manobras em chaves presentes na rede primária. Uma vez que tais redes operam com topologia radial, a ocorrência de uma falta pode resultar no desligamento de consumidores saudáveis. Desta maneira, o problema consiste em definir, num curto intervalo de tempo, um número mínimo de chaves que devem ser operadas a fim de isolar a falta e restaurar o máximo de consumidores saudáveis desligados. Os esforços para a obtenção de ferramentas computacionais para fornecimento de soluções para o problema de restabelecimento têm sido intensificados nos últimos anos. Isto ocorre, em especial, devido aos enormes prejuízos causados pela falta de energia às companhias de eletricidade e a toda a sociedade. Neste sentido, o objetivo deste trabalho é a obtenção de um método para auxiliar o trabalho dos operadores através do fornecimento de planos adequados de restabelecimento em curtos intervalos de tempo. Os diferenciais deste método proposto são a sua capacidade de: lidar, em especial, com redes reais de grande porte com reduzido esforço computacional; considerar a existência de vários níveis de prioridade de atendimento entre os consumidores (note, por exemplo, que um hospital ou um centro de segurança pública devem ter maior prioridade de atendimento que um grande supermercado ou unidades residenciais) e priorizar o atendimento deles de acordo a sua prioridade; fornecer uma sequência por meio da qual as chaves possam ser operadas a fim de isolar os setores em falta e reconectar o maior número de consumidores saudáveis desligados executando-se o mínimo de manobras em chaves e priorizando os consumidores com maior prioridade; ser capaz de selecionar cargas menos prioritárias para permaneceram desligadas nas situações em que não é possível obter uma solução que restaure todas as cargas saudáveis fora de serviço; e, adicionalmente, priorizar a operação de chaves controladas remotamente, que, diferentemente das chaves controladas manualmente, podem ser operadas com menores custos e de maneira mais rápida. O método proposto consiste, de maneira sintética, na união de uma busca exaustiva aplicada localmente a um novo algoritmo evolutivo multi-objetivo em tabelas de subpopulação que faz uso de uma estrutura de dados eficiente denominada Representação Nó-Profundidade. Para avaliar a performance relativa do método proposto, simulações foram realizadas num sistema de distribuição de pequeno porte e os resultados foram comparados com os obtidos por um método de Programação Matemática. Na sequência, novos experimentos foram realizadas em diversos casos de falta na rede de distribuição da cidade de Londrina-PR e cidades adjacentes. As soluções fornecidas mostraram-se adequadas ao tratamento dos casos de falta, assim como as sequências de chaveamento associadas a elas, as quais foram capazes de priorizar o restabelecimento dos consumidores prioritários seguindo seus níveis de prioridade. Adicionalmente, estudos avaliaram a variação do tempo de processamento computacional do método proposto com a dimensão das redes de distribuições e também com o número de gerações realizadas pelo algoritmo evolutivo multi-objetivo proposto e os resultados mostraram-se satisfatórios às necessidades do problema Portanto, pode-se comprovar que o método proposto atingiu os objetivos especificados, em especial, o tratamento de aspectos práticos do problema. Além do próprio método proposto, algumas contribuições desta pesquisa são a proposição um novo algoritmo evolutivo multiobjetivo em tabelas de subpopulação e de um novo operador para manipulação de florestas de grafo armazenadas pela Representação Nó-Profundidade e voltado ao problema de restabelecimento. / In the context of distribution systems operation, service restoration is one of the problems with which operators constantly deal. It arises when a permanent fault occurs and is treated trough operations in switches at primary grid. Since distribution systems are usually radial, fault occurrence turns-off healthy customers. Thereby, the service restoration problem consists in defining, in a short processing time, the minimum amount of switches that must be operated for the isolation of the fault and reconnection of the maximum amount of healthy out-of-service customers. The efforts of developing computational tools for getting solution to this problems has increased in the last years. It is, in special, due to enormous losses caused to the utilities and to the whole society. In this sense, the main objective of this research is getting a method able to help the distribution system operator\'s work through providing service restoration plans quickly. The differentials of this research are its ability to: deal, in special, with large scale grids whit a reduced computational effort; consider costumers of several priority levels (note, for instance, a hospital has a higher supply priority in relation to a big supermarket) and prioritize the higher priority customers; provide a switching sequence able to isolate and reconnect the maximum amount of healthy out-of-service customer by the minimum amount of switching actions; select lower priority customers to keep out-of-service in order to reconnect higher priority customers when a it is not possible to restore all customers; and, additionally, prioritize switching operation in remotely controlled switches, whose operation is faster and cheapest than the operation of manually controlled switches. The proposed method mixes a local exhaustive search and a new multi-objective evolutionary algorithm in subpopulation tables that uses a data structure named Node-Depth Encoding. For evaluating the relative performance of proposed method, simulations were performed in small distribution systems and the performance was compared with the performance a Mathematical Programing method from literature. New experiments were performed a Mathematical Programing method from literature. New experiments were performed in several fault situations in the real and large-scale distribution system of Londrina-PR and adjacent cities. The solutions provided were appropriated to the treatment of such contingency situations. The same occurs with the switching sequences provided, which were able to prioritize the restoration of higher priority customers. Additional studies evaluated the variation of the running time with the size of grids and with the values adopted for the maximum number of generations of the evolutionary algorithm (which is an input parameter). The results expressed the running time of the proposed method is suitable to the problem needs. Therefore, it could be proved the proposed method achieved the specified objectives, in special, the treatment of practical aspects of the problem. Besides the proposed method, some contributions of this research are proposition of a new multi-objective evolutionary algorithm in subpopulation tables and a new reproduction operator to manipulate graph forests computationally represented by Node-Depth Encoding.

Page generated in 0.0611 seconds