• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • 28
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 96
  • 96
  • 64
  • 60
  • 27
  • 18
  • 16
  • 16
  • 16
  • 16
  • 14
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Avaliação do uso de placas sinterizadas de titânio com e sem recobrimento de beta-fosfato tricálcico no reparo de falhas ósseas em calvária de ratos = Evaluation of sintered titanium scaffolds with and without beta-tricalcium phosphate coating for calvarial defects repair in rats / Evaluation of sintered titanium scaffolds with and without beta-tricalcium phosphate coating for calvarial defects repair in rat

Calderoni, Davi Reis, 1982- 26 August 2018 (has links)
Orientadores: Paulo Kharmandayan, Ivan Felizardo Contrera Toro / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-26T14:18:09Z (GMT). No. of bitstreams: 1 Calderoni_DaviReis_D.pdf: 2411163 bytes, checksum: f124b9aeaf19c6f4e86c382fef12ffeb (MD5) Previous issue date: 2014 / Resumo: Introdução: A reparação de um defeito craniano é um procedimento desafiador, que requer não somente o preenchimento da falha óssea mas também estabilidade a longo prazo do material empregado e restabelecimento do contorno e simetria. Diversos tipos de materiais com diferentes características bem como diferentes métodos de produção dos implantes vêm sendo testados, sem que ainda haja um substituto ósseo considerado ideal. No presente estudo foram investigadas as propriedades de osteointegração de implantes da liga Ti6Al4V construídos por prototipagem com poros tridimensionalmente conectados considerando a influência do recobrimento dos mesmos com uma camada delgada de ?-fosfato tricálcico nestas propriedades. Método: Trinta ratos foram submetidos à criação de defeitos ósseos bilaterais na calvária, que foram preenchidos com implantes, recobertos ou não com ?-fosfato tricálcico, de modo aleatório. Os animais foram distribuídos em grupos e sacrificados 15, 45 e 90 dias após o procedimento. A integração dos implantes foi inicialmente avaliada por ensaio de compressão. A interface osso-implante foi analisada por meio de microscopia eletrônica de varredura. Resultados: A força máxima para produzir o deslocamento inicial dos implantes foi aumentando durante o período estudado, alcançando valores da ordem de 100N para ambos os tipos de implante. Foi observada integração entre o osso e a superfície dos implantes, com crescimento ósseo progressivo no interior dos poros. Não foram observadas diferenças significativas entre implantes recobertos e não recobertos por ?-fosfato tricálcico. Conclusão: Foi alcançada uma adequada osteointegração nas reconstruções cranianas utilizando implantes prototipados da liga Ti6Al4V com as características de porosidade e superfície descritas, sem influência do recobrimento cerâmico adotado. Os resultados sugerem que as características de construção utilizadas podem ser incorporadas aos implantes para reconstrução craniana para melhorar os resultados cirúrgicos / Abstract: Background: The repair of a calvarial defect is a challenging procedure, requiring not only filling of the bone gap but long term stability of the employed material and satisfactory contour and symmetry. Several types of materials with different characteristics have been studied, as well as various methods of implant production. However, to date no ideal bone substitute has been found. The osseointegration properties of porous prototyped implants with tridimensionally interconnected pores made of the Ti6Al4V alloy and the influence of a thin layer of calcium phosphate coating were investigated. Methods: Bilateral critical size calvarial defects were produced in thirty rats and filled with coated and uncoated implants in a randomized fashion. The animals were distributed in groups and kept for 15, 45 and 90 days before sacrifice. Implant mechanical integration to bone was evaluated with a push-out test. Bone-implant interface was analyzed using scanning electron microscopy. Results: The maximum force to produce initial displacement of the implants increased during the study period, reaching values around 100N for both types of implants. Intimate contact between bone and implant surface was present, with progressive bone growth into the pores. No significant differences were seen between coated and uncoated implants. Conclusion: Adequate osseointegration can be achieved in calvarial reconstructions using prototyped Ti6Al4V scaffolds with the described physical characteristics of surface and porosity. The results suggest that the proposed implant design characteristics can be incorporated into calvarial implants to improve reconstructive results. / Doutorado / Fisiopatologia Cirúrgica / Doutor em Ciências
62

Distribuição de tensões ao redor dos implantes em duas condições de desajuste vertical / Stress Distribution around implants in two conditions of vertical misfit

Castro, Gabriela Cassaro de, 1986- 02 September 2015 (has links)
Orientador: Mauro Antonio de Arruda Nóbilo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-26T22:26:53Z (GMT). No. of bitstreams: 1 Castro_GabrielaCassarode_D.pdf: 33391431 bytes, checksum: 639a953ad32049093199c81dd2ea3cb7 (MD5) Previous issue date: 2015 / Resumo: Muito se discute sobre importância da passividade, seus efeitos mecânicos e biológicos e a dificuldade em sua obtenção. Devido aos procedimentos inerentes ao processo de confecção da infraestrutura metálica, desde a moldagem à fundição, distorções são incorporadas. Estas tornam-se preocupação biomecânica por gerar tensão no conjunto prótese-implante-osso. Propõe-se avaliar as tensões ao redor dos implantes em infraestruturas de Titânio para prótese total fixa sobre 4 implantes, com diferentes desajustes marginais por meio da fotoelasticidade. Quatro implantes hexágono externo 4,1 x 11,5 mm, foram posicionados sobre uma matriz simulando uma mandíbula edêntula e nomeados da esquerda para direita em A, B, C e D. Aos implantes, foram aparafusados mini-pilares cônicos e entre os pilares e a infraestrutura foram posicionados anéis espaçadores com dimensões conhecidas: para o grupo HE300 (n=5) foi simulado desajuste, respectivamente de A-D: 0 µm, 100 µm, 200 µm e 300 µm, para o grupo HE100 (n=5) apenas desajuste de 100 µm no implante D. A matriz foi duplicada em resina fotoelástica utilizando as infraestruturas como transferente de moldagem. Foram realizadas medições em 6 pontos em cada implante através do teste do parafuso único, em microscópio óptico, para aferir a desadaptação real obtida. Para obter as imagens fotoelásticas padronizadas a infraestrutura foi aparafusada aos pilares e levadas ao polariscópio circular. A tensão cisalhante máxima (Kgf) foi aferida em 7 pontos ao redor de cada implante e comparados quanto as tensões conjuntas em todos os implantes, ao redor de cada implante e na região cervical e apical. Os dados foram tabulados e submetidos à análise estatística pelo teste t de Student, para avaliar a diferença entre as médias de desadaptação e tensão e o teste de correlação de Spearman para verificar a relação entre tensão e desadaptação. A desadaptação média observada foi de 56,96 (±13,23) ?m para o grupo HE100 e de 194,53 (±162,98) ?m para HE300, apresentando diferença entre os grupos. Com relação à tensão, os grupos HE300 e HE100 mostraram-se iguais estatisticamente (p = 0,291). Mas verificou-se correlação positiva entre desadaptação e tensão em HE100 e HE300. Os implantes B, C e D apresentaram maior tensão no grupo HE100 (p < 0,0001) e no grupo HE300, não foi constatado diferença entre os implantes. As tensões foram maiores na cervical do que na região apical em ambos grupos, para HE 100: 36,92 (±9,33) Kgf na região cervical e 17,78 (±4,09) Kgf na região apical; para HE300: 50,37 (±13,20) Kgf na região cervical e para a região apical 21,20 (±3,95) Kgf. O grupo HE300 exibiu significantemente maior valor de tensão na região cervical (p = 0,012). Conclui-se que o desajuste obtido em HE300 foi maior que do grupo HE100 e gerou maior tensão na região cervical. Ao analisar os implantes em conjunto as tensões foram semelhantes estatisticamente. Foi observado correlação entre desajuste e tensão em ambos grupos. Nas duas situações simuladas, a tensão na região cervical foi maior que na apical / Abstract: There is concern over the importance of passivity, its mechanical and biological effects and the difficulty to obtain it. Misalignments are incorporated due to the procedures inherent in the manufacture of the metal frameworks process, from impression to casting. This becomes a biomechanical concern for generating tension in the prosthesis-implant-bone set. It proposes to analyze the stresses around the implants after being bolted with Titanium frameworks for fixed dentures on 4 implants with different marginal misfits through photoelasticity. Four external hex implants, 4.1 x 11.5 mm, were positioned on a matrix simulating an edentulous jaw and named from left to right, A, B, C and D, respectively. Tapered mini-pillars were screwed to the implants and between the pillars and frameworks were positioned spacer rings with known dimensions: For the HE300 (n=5) group there was a simulated misfit, with AD: 0 microns, 100 microns, 200 microns and 300 microns, respectively. For the just misfit HE100 (n=5) group of 100 microns in implant D, the matrix was duplicated in photoelastic resin using the framework as transfer abutment. Measurements were performed in 6 points in each implant, with the single screw test and an optical microscope to measure the real mismatch obtained. For the standardized photoelastic images, infrastructure was bolted to the columns and analyzed at circular polariscope. The maximum shear stress (kgf) was measured at 7 points around each implant and compared as joint stresses in all implants around each implant, cervical and apical region. Data were tabulated and submitted to statistical analysis by Student's t-test, to evaluate the difference between the means of misfit and tension, and the Spearman correlation test to verify the relationship between stress and maladjustment. The average misfit observed was 56.96 (±13.23) microns for the HE100 group, and 194.53 (±162.98) microns for HE300, with differences between groups. Regarding the strain, the HE300 and HE100 groups were statistically equal (p = 0291). Yet there was a positive correlation between misfit and strain into HE100 and HE300. The B, C and D implants presented a higher tension in the HE100 group (p <0.0001) and HE300 group difference was not observed between the implants. Tensions were higher in the cervical than in the apical region in both groups, for HE100: 36.92 (±9.33) and 17.78 (±4.09) kgf in the cervical region, and in the apical region; for HE300: 50.37 (±13.20) kgf in the cervical region, and the apical region 21.20 (±3.95) Kgf. The HE300 group exhibited significantly more tension the cervical region (p = 0.012). It is concluded that the misfit obtained in HE300 was higher than the misfit group HE100 and generated increased tension in the cervical region. However, the analysis of the photoelastic model found tensions to be equal. A direct relationship between misfit and tension was observed in both groups. In both cases simulated, the tension in the cervical region was larger than in the apical / Doutorado / Protese Dental / Doutora em Clínica Odontológica
63

Influência da soldagem (Laser ou TIG) em estruturas de titânio sobre o desajuste marginal (bi e tridimensional), força de destorque em parafusos protéticos, fadiga mecânica, corrosão e tensão induzida aos pilares protéticos de próteses implantossuportadas = Influence of welding (Laser or TIG) on marginal misfit (two and three-dimensional), detorque strength in prosthetic screws, mechanical fatigue, corrosion and stress induced to the prosthetic abutment of implant-supported prostheses / Influence of welding (Laser or TIG) on marginal misfit (two and three-dimensional), detorque strength in prosthetic screws, mechanical fatigue, corrosion and stress induced to the prosthetic abutment of implant-supported prostheses

Rodrigues, Sabrina Alessandra, 1986- 27 August 2018 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T20:29:16Z (GMT). No. of bitstreams: 1 Rodrigues_SabrinaAlessandra_D.pdf: 2058256 bytes, checksum: 25d619422634beb160a254baa71e150a (MD5) Previous issue date: 2015 / Resumo: O objetivo neste estudo foi avaliar o comportamento de estruturas fundidas em titânio, soldadas à LASER (Light Amplification by Stimulated Emission of Radiation) e à TIG (Tungsten Inert Gas), em relação ao desajuste marginal (bi e tridimensional), força de destorque dos parafusos protéticos, fadiga mecânica, corrosão e tensão induzida aos análogos de mini pilares protéticos. Cinquenta estruturas foram fundidas em titânio comercialmente puro (Ti-cp); vinte infraestruturas (n=20) simulando próteses fixas múltiplas de três elementos; e trinta halteres (n=30). Para cada infraestrutura foram confeccionados dois tipos de index, simulando um desajuste marginal de 200 µm. Um index em gesso especial, para desenvolvimento da análise de tensão, e outro em resina fotoelástica, para avaliação do desajuste marginal (bi e tridimensional), força de destorque, fadiga mecânica e corrosão. Antes e após os procedimentos de soldagem (LASER ou TIG) foram realizadas as seguintes avaliações: mensuração do desajuste marginal, por meio de microscópio óptico (bidimensional) e microtomógrafo de raio-X (tridimensional); análise da tensão induzida aos mini pilares protéticos, por meio da técnica extensométrica; e mensuração da força de destorque dos parafusos protéticos. Os procedimentos de soldagem foram relizados com os seguintes parâmentros: LASER (370/9ms); TIG (36A/60ms). Após a realização dos procedimentos de soldagem (LASER ou TIG) as infraestruturas foram submetidas à ciclagem mecânica ( 280 N/ 106 ciclos /2Hz) para avaliação da força de destorque dos parafusos protéticos pós-ciclagem. A longevidade das estruturas intactas e soldadas (LASER ou TIG) também foi avaliada, por meio de ensaios mecânicos de fadiga, e o comportamento à corrosão, por meio de testes eletroquímicos de espectroscopia de impedância eletroquímica e polarização potenciodinâmica. Os resultados foram analisados estatisticamente (ANOVA fator único/ Teste de Tukey HSD/Teste t de Student/ (?=0,05)). Ambos os procedimentos de soldagem diminuíram o nível de desajuste marginal (bi e tridimensionalmente), aumentaram a intensidade da força de destorque e reduziram a tensão induzida aos mini pilares protéticos. Contudo, após a ciclagem mecânica houve diminuição da intensidade da força de destorque dos parafusos protéicos. As estruturas soldadas à LASER tiveram maior resistência a fadiga, comparada as estruturas soldadas à TIG. O teste de espectroscopia de impedância foi significativo para as infraestruturas soldadas à TIG, comparado com as infraestruturas intactas e soldadas à LASER. Conclui-se que os procedimentos de soldagem tiveram influência sobre a adaptação marginal das infraestruturas, proporcionando maior estabilidade ao sistema implantossuportado. A ciclagem mecânica teve influência sobre a estabilidade dos parafusos protéticos, sendo necessárias proservações periódicas durante o uso da prótese para reaperto e/ou troca dos parafusos. Estruturas fundidas em titânio e soldadas à LASER possuem maior resistência à fadiga do que estruturas soldadas à TIG. Eletroquimicamente, o procedimento de soldagem à LASER possuem melhor comportamento à corrosão comparado ao procedimento de soldagem à TIG / Abstract: The aim of this study was to evaluate titanium casted structures behavior, welded by LASER (Light Amplification by Stimulated Emission of Radiation) and TIG (Tungsten Inert Gas), on marginal misfit (two and three-dimensional), prosthetic screws detorque strength, mechanical fatigue, corrosion and stress induced to the prosthetic mini abutment analogs. Fifty structures were casted in commercially pure titanium (cp-Ti); twenty frameworks (n=20) simulating multiple prostheses of three elements; and thirty dumbbells (n=30). From the frameworks were fabricated two type of index, simulating a marginal misfit of 200µm. One index was fabricated in special plaster to the development of stress analysis, and other in epoxy resin to the development of marginal misfit analysis (two and three-dimensional), detorque strength, mechanical fatigue and corrosion. Before and after welding procedures (LASER or TIG) were developed the following evaluation: marginal misfit analysis, by optical microscope (two-dimensional) and X-ray microtomography (three-dimensional); induced stress analysis on prosthetic mini abutment analogs, by extensometric technique; and measurement of prosthetic screws detorque strength. The welding procedures were made with the following parameters: LASER (370V/9ms); TIG (36A/60ms). After welding procedures (LASER or TIG), the frameworks were submitted to cyclic mechanical (280N; 106 cycles; 2 Hz) by oblique compressive load to evaluation of the detorque strength after the cycling. The longevity of the welded structures was also evaluated by mechanical fatigue testing, and the corrosion behavior by electrochemical tests of electrochemical impedance spectroscopy and potentiodynamic polarization. The results were analyzed statistically (one-way ANOVA / Tukey HSD test / Student-t test (? = 0.05)). Both the welding procedures decreased the marginal misfit level (two and three-dimensionally), increased the detorque strength and decreased of stress induced on prosthetic mini abutment analogs. However, after the mechanical cycling there was decrease of detorque strength of prosthetic screws. The structures welded by LASER had high fatigue resistance than the structures welded by TIG. The impedance spectroscopy test was only significant for frameworks welded by TIG, compared with intact and LASER welded LASER frameworks. It is concluded that welding procedures had influence on marginal fit, providing more stability to the implant-supported system. The mechanical cycling had influence on prosthetic screws stability, being necessary periodic following up to tighten and/or exchange of prosthetic screws. The titanium casted and LASER welded structures were more fatigue resistance than that TIG welded structures. Electroless, LASER welding procedure have better corrosion behavior compared to TIG welding procedure / Doutorado / Protese Dental / Doutora em Clínica Odontológica
64

Gastrointestinal and Biliary Indwelling Devices

Stack, P E., Patel, N R., Thomas, E 01 August 1994 (has links)
Esophageal and biliary stents are indwelling devices used in the treatment of selected gastrointestinal and biliary disorders. Stenting is accepted as a standard procedure for palliation of malignant obstruction of the esophagus and biliary system. Review of the early and late complications associated with these devices is made with emphasis on the clinical and radiographic features. A suggested approach to diagnosis and treatment recommendations are made for each complication that the emergency department physician may encounter.
65

Efeito do processo de envelhecimento sobre propriedades físicas e biológicas de biomateriais utilizados como abutments /

Rocha, José Francisco Santos Simões da January 2018 (has links)
Orientador: Janaína Habib Jorge / Resumo: O objetivo deste estudo foi avaliar o efeito do envelhecimento de materiais comumente usados como pilares de próteses implanto-suportadas (abutments) sobre suas características físicas de superfície (rugosidade, energia livre de superfície e molhabilidade) e propriedades biológicas (metabolismo de fibroblastos orais e formação de biofilme fúngico). Para isso, discos (N=62) com rugosidade inferior a 0,2 µm foram confeccionados em zircônia (ZrO2) do tipo Y-TZP (yttriumstabilized tetragonal zirconia polycrystalline) e em titânio (Ti) comercialmente puro, e foram submetidos a um processo de envelhecimento simulado em autoclave a 134ᵒC (pressão de 2 bar) por 20 horas. ZrO2 e Ti envelhecidos foram comparados aos seus homólogos não envelhecidos. Os materiais também foram comparados entre si, nas condições envelhecida e não envelhecida. Para os testes biológicos, os grupos também foram comparados a um controle positivo de poliestireno. Todos os testes, exceto o de rugosidade, foram realizados após a formação de película salivar sobre os discos. Os testes biológicos utilizados foram de Alamar Blue (n=9) para avaliar o metabolismo de fibroblastos da gengiva humana (FGH) e de contagem de colônias viáveis (n=9) para verificar a formação de biofilme de uma cepa padrão de Candida albicans (ATCC90028) sobre os materiais. Além disso, microscopia eletrônica de varredura (MEV) (n=2) foi realizada para avaliação da morfologia dos fibroblastos e dos microrganismos. Para a análise estatística, fo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the effect of aging of commonly used abutments on their surface physical characteristics (roughness, surface free energy and wettability) and biological properties (oral fibroblasts metabolism and formation of fungal biofilm). For this purpose, discs (N=62) with roughness less than 0.2 μm were made in yttrium-stabilized tetragonal zirconia polycrystalline (Y-TZP) zirconia (ZrO2) and in commercially pure titanium (Ti), and underwent a simulated aging process in autoclave at 134 °C (pressure of 2 bar) for 20 hours. ZrO2 and Ti were compared to their unaged counterparts. The materials were also compared to each other in the aged and unaged conditions. For the biological tests, the groups were also compared to a positive control of polystyrene. All tests, except roughness, were performed after the formation of salivary film on the discs. The biological tests used were Alamar Blue (n=9) to evaluate the metabolism of human gingival fibroblasts (HGF) and colony counting test (n=9) to verify the biofilm formation of a reference strain of Candida albicans (ATCC90028) on the materials. In addition, scanning electron microscopy (SEM) (n=2) was performed to evaluate the morphology of fibroblasts and microorganisms. For statistical analysis, the t-test for paired samples was used for roughness, t-test for independent samples was used for surface free energy, wettability and fibroblasts metabolism, and one-way ANOVA with Welch correction and Games-Howe... (Complete abstract click electronic access below) / Mestre
66

Estudo da correlação entre adaptação marginal e tensões transmitidas aos implantes por estruturas metálicas fundidas em monobloco - análise fotoelástica. / A study of the correlation between marginal fit and tensions transmitted to implants by one-piece metal castings - a photoelastic analysis.

Torres, Érica Miranda de 19 December 2005 (has links)
Um dos maiores obstáculos para o sucesso das reabilitações com próteses sobre implantes consiste na obtenção de boa adaptação marginal dos componentes protéticos. Não está claro na literatura quais níveis de desajuste são considerados clinicamente aceitáveis, mas sabe-se que a ausência de perfeito ajuste e assentamento passivo pode provocar tensões inadequadas na interface de osseointegração, possibilitando problemas mecânicos e biológicos. A fotoelasticidade é uma técnica experimental para análise de tensões capaz de produzir resultados bastante confiáveis e fiéis aos parâmetros clínicos. Quando estruturas metálicas para próteses sobre múltiplos implantes são fundidas em monobloco, a obtenção de boa adaptação marginal parece ser ainda mais crítica. Contudo, não se verificam estudos que abordem a influência do tipo de metal ou liga empregado nessas fundições sobre os níveis de desadaptação protética. Assim, o presente estudo tem como objetivos verificar a adaptação marginal entre os pilares intermediários e estruturas fundidas em monobloco com diferentes materiais; avaliar, pelo método fotoelástico, as tensões impostas aos implantes quando a eles são fixadas as estruturas metálicas; e ainda pesquisar possíveis correlações entre os níveis de adaptação marginal e as tensões geradas na interface implante-material fotoelástico. Para tanto, utilizando cilindros calcináveis, foram enceradas 15 estruturas para próteses implanto-retidas sobre modelo simulando o posicionamento de cinco implantes na região intermentoniana. As estruturas foram divididas em grupos de cinco e fundidas em monobloco com titânio comercialmente puro grau I, liga de cobalto-cromo ou liga de níquel-cromo-titânio. A adaptação marginal foi avaliada, em microscópio ótico, quanto à passividade, por meio do teste de único parafuso, com aperto alternado nos implantes distais A e E, e quanto aos níveis de desajuste vertical, com todos os parafusos apertados com um torque de 10Ncm. As tensões geradas na área correspondente à região de crista óssea marginal em torno dos implantes foram avaliadas por meio de análise fotoelástica quantitativa empregando o método de compensação de Tardy. Após análise estatística dos resultados (p<0.05), verificou-se que, nos testes de passividade, o Ti cp apresentou resultados significantemente superiores de adaptação quando comparado as ligas de Co-Cr e Ni-Cr-Ti, as quais não apresentaram diferenças estatísticas entre si. O Ti cp foi semelhante à liga de Ni-Cr-Ti quanto aos níveis de desajuste vertical e tensões impostas aos implantes, com resultados superiores àqueles obtidos com a liga de Co-Cr. Foram aplicados testes de correlação entre as tensões fotoelásticas e os seguintes parâmetros: desajuste vertical, passividade média, adaptação marginal absoluta e percentual de redução de desajuste. Verificou-se correlação significante apenas entre os valores de adaptação marginal absoluta e tensões geradas pelas estruturas de Ni-Cr-Ti. Pode-se concluir que estruturas para próteses fixas sobre múltiplos implantes fundidas em monobloco podem produzir níveis biologicamente aceitáveis de desajuste, sendo os melhores resultados obtidos com o Ti cp, seguido das ligas de Ni-Cr-Ti e Co-Cr, respectivamente. Dentre os metais avaliados, a liga de Co-Cr transmitiu maiores níveis de tensões aos implantes. De um modo geral, não foram verificadas correlações entre valores de adaptação marginal e tensões impostas aos implantes. / Obtaining a good marginal fit of the prosthetic components is one of the main obstacles to the success of rehabilitation with implant-supported prostheses. It is not clear, in the literature, which misfit levels are considered clinically acceptable, but it is known that the absence of a perfect and passive fit may cause inadequate tensions on the osseointegration interface, which may bring about mechanical and biological problems. Photoelasticity is an experimental technique, used to analyze tensions, which is capable of producing results that are reliable to clinical parameters. When metal multiple-unit implant frames are cast in a single unit, it seems that obtaining a good marginal fit is even more critical. However, there are no studies in the literature about the influence that the type of metal or alloy used in these castings may have on the levels of prosthesis misfit. Thus, the present study has the aim to verify the marginal fit between the intermediate abutments and the one-piece structures cast with different materials; perform a photoelastic assessment of the tensions caused on implants when metal frames are fixed to them; and, research the possible correlations between the levels of marginal fit and the tensions generated on the interface implant-photoelastic material. To do this, 15 frames for implant-retained prostheses were waxed, using calcinable cylinders, simulating the positioning of five implants on the inter-mentalis region. The frames were divided into groups (n=5) and cast in a single piece with commercially pure titanium grade I, cobalt-chrome alloy, or nickel-chrome-titanium alloy. Marginal fit was assessed by optic microscopy, in terms of passivity, by a single screw test with alternate tightening on the distal implants A and E. As to the levels of vertical misfit, all screws were tightened to a torque of 10Ncm. Tensions generated in the area corresponding to the marginal bone crest region surrounding the implants were assessed by quantitative photoelastic analysis using the Tardy compensation method. After the statistical analysis of the results (p<0.05), it was verified that, in the passivity tests, the Ti cp showed significantly superior fitting results when compared to the Co-Cr and Ni-Cr-Ti alloys, which showed no statistically significant differences between them. In terms of the levels of vertical misfit and tensions over the implants, Ti cp was similar to the Ni-Cr-Ti alloy, showing superior results when compared to the Co-Cr alloy. Correlation tests were performed between the photoelastic tensions and the following parameters: vertical misfit, mean passivity, absolute marginal fit, and percentage of misfit reduction. A significant correlation was observed only between the values of absolute marginal fit and the tensions generated by the Ni-Cr-Ti frames. It is concluded that one-piece cast multiple-unit implant frames may produce biologically acceptable misfit levels, and the best results are obtained with Ti cp, followed by the Ni-Cr-Ti and Co-Cr alloys, respectively. Among the assessed metals, the Co-Cr alloy transmitted higher tension levels to the implants. In a general way, no correlations were observed between the values of marginal fit and tensions on implants.
67

Avaliação de próteses fixas sobre implantes com diferentes níveis de ajuste pilar/prótese: efeito da ciclagem termomecânica sobre diferentes parafusos protéticos e análise fotoelástica da transmissão de tensões / Evaluation of fixed implant-supported prostheses with different levels of abutment/prosthesis fit: the effect of thermomechanical cycling on different abutment screws and photoelastic analysis of stress transmission

Silva, Rafael Candido Pedroso e 05 June 2012 (has links)
O objetivo deste estudo foi verificar os efeitos da ciclagem termomecânica sobre parafusos protéticos, convencionais de titânio e com cobertura de carbono, usados para fixação de próteses parciais fixas com desajuste de 150µm entre pilar e prótese, utilizando próteses sem desajuste como controle. Após ciclagem termomecânica das próteses, foram verificadas a adaptação marginal, a perda de torque dos parafusos protéticos e análise fotoelástica da distribuição de tensões ao redor dos implantes. Foram confeccionadas 12 próteses fixas sobre implantes, as quais foram divididas inicialmente em dois grupos (n=6): grupo 1 - sem desajuste (controle); grupo 2 - com desajuste simulado de 150&mu;m. Todas as próteses foram avaliadas em relação à adaptação marginal antes e após a simulação de ciclos mastigatórios. Os conjuntos foram submetidos a um total de 2.000.000 de ciclos mastigatórios, sendo que estes ensaios foram feitos duas vezes e os grupos iniciais foram subdivididos, na primeira vez foram utilizados parafusos com cobertura de carbono: grupo 1A (adaptadas) e grupo 2A (desadaptadas) e na segunda vez parafusos de titânio convencionais: grupo 1B (adaptadas) e grupo 2B (desadaptadas). A perda de torque dos parafusos foi analisada antes (T0), após 1.000.000 (T1) e 2.000.000 de ciclos (T2). A adaptação marginal após o ensaio melhorou significativamente ao se utilizar parafusos convencionais nas próteses adaptadas: pré-molar (p=0,001) e molar (p=0,028); e desadaptadas: pré-molar (p=0,014) e molar (p=0,007); mas ao se utilizar parafusos cobertos com carbono, a adaptação melhorou somente no pré-molar (p=0,015) das próteses desadaptadas. Quanto à perda de torque dos parafusos protéticos houve diferenças significantes antes e após a simulação dos ciclos mastigatórios entre as próteses adaptadas e desadaptadas, no molar, em todos os tempos para ambos parafusos (p&le;0,05); No pré-molar houve diferença significante apenas para os parafusos cobertos com carbono em T0 (p=0,019) e T2 (p=0,044). Quando comparados os parafusos, nas próteses adaptadas houve diferenças significantes no pré-molar em T1 (p=0,026) e T2 (p=0,043); e no molar em T2 (p=0,032); nas próteses desadaptadas houve diferenças significantes apenas para o pré-molar em T1 (p=0,046). Em relação à análise fotoelástica qualitativa, observou-se que em geral a aplicação de carga (10Kgf) gerou maior concentração e intensidade de tensões nas próteses desadaptadas, quando comparadas às adaptadas. Pode-se concluir que a simulação de ciclos mastigatórios teve influência sobre a adaptação marginal das próteses; em relação a perda de torque houve diferenças estatisticamente significantes entre as próteses adaptadas e desadaptadas; o tratamento de superfície dos parafusos foi eficaz apenas para próteses adaptadas, a análise fotoelástica sugere que próteses com desadaptações marginais provocam maior tensão ao redor dos implantes. / The objective of this study was to investigate the effects of thermomechanical cycling on prosthetic screws, conventional titanium and carbon coated, used for fixation of fixed partial dentures (FDP) with 150&mu;m of misfit between abutment and prosthesis, using fitted prostheses as control. After thermomechanical cycling of prostheses were verified, the marginal fit, the torque loss of prosthetic screws and the photoelastic analysis of stress distribution around implants. Twelve implant-supported fixed partial dentures were prepared and initially divided into two groups (n=6): group 1 - fitted prostheses (control), group 2 - 150&mu;m of simulated misfit. All prostheses had their marginal fit evaluated before and after simulation of cycles. The sets were subjected to a total of 2 million of cycles. Each group was assayed twice: in the first time, carbon coated screws were used: group 1A (fitted) and group 2A (misfitted); and in a second time, conventional titanium screws were used: group 1B (fitted) and group 2B (misfitted). The torque loss of the screws was analyzed before (T0), after 1,000,000 (T1) and 2,000,000 cycles (T2). Marginal fit improved significantly when using conventional screws in fitted prostheses: premolar (p=0,001) and molar (p=0,028), and in misfitted prostheses: premolar (p=0,014) and molar (p=0,007), but when using carbon coated screws, fit improved only in the premolar (p=0,015) of the misfitted prostheses. Torque loss of prosthetic screws were significantly different before and after simulation of the cycles between the fitted and misfitted, in molar, at all times for both screws (p&le;0,05); and in the premolar, were significant differences were noted only for the carbon coated screws at T0 (p=0,019) and T2 (p=0,044).When comparing the screws in the fitted prostheses, significant differences were noted in pre-molar at T1 (p=0,026) and T2 (p=0,043), and in the molar at T2 (p=0,032); whereas in the misfitted prostheses, significant difference was noted only for premolar at T1 (p=0,046). It was observed in qualitative photoelastic analysis that the load application (10Kgf) generated higher concentration and intensity of stresses in the misfitted prostheses, when compared to fitted ones. It can be concluded that the simulation of thermomechanical cycles had an influence on marginal fit of the prostheses. In relation to torque loss, differences between fitted and misfitted prostheses were noted, but the surface treatment of screws was effective only for fitted prostheses, and the photoelastic analysis suggests that prostheses with marginal misfit causes more stress around the implants.
68

Estudo da correlação entre adaptação marginal e tensões transmitidas aos implantes por estruturas metálicas fundidas em monobloco - análise fotoelástica. / A study of the correlation between marginal fit and tensions transmitted to implants by one-piece metal castings - a photoelastic analysis.

Érica Miranda de Torres 19 December 2005 (has links)
Um dos maiores obstáculos para o sucesso das reabilitações com próteses sobre implantes consiste na obtenção de boa adaptação marginal dos componentes protéticos. Não está claro na literatura quais níveis de desajuste são considerados clinicamente aceitáveis, mas sabe-se que a ausência de perfeito ajuste e assentamento passivo pode provocar tensões inadequadas na interface de osseointegração, possibilitando problemas mecânicos e biológicos. A fotoelasticidade é uma técnica experimental para análise de tensões capaz de produzir resultados bastante confiáveis e fiéis aos parâmetros clínicos. Quando estruturas metálicas para próteses sobre múltiplos implantes são fundidas em monobloco, a obtenção de boa adaptação marginal parece ser ainda mais crítica. Contudo, não se verificam estudos que abordem a influência do tipo de metal ou liga empregado nessas fundições sobre os níveis de desadaptação protética. Assim, o presente estudo tem como objetivos verificar a adaptação marginal entre os pilares intermediários e estruturas fundidas em monobloco com diferentes materiais; avaliar, pelo método fotoelástico, as tensões impostas aos implantes quando a eles são fixadas as estruturas metálicas; e ainda pesquisar possíveis correlações entre os níveis de adaptação marginal e as tensões geradas na interface implante-material fotoelástico. Para tanto, utilizando cilindros calcináveis, foram enceradas 15 estruturas para próteses implanto-retidas sobre modelo simulando o posicionamento de cinco implantes na região intermentoniana. As estruturas foram divididas em grupos de cinco e fundidas em monobloco com titânio comercialmente puro grau I, liga de cobalto-cromo ou liga de níquel-cromo-titânio. A adaptação marginal foi avaliada, em microscópio ótico, quanto à passividade, por meio do teste de único parafuso, com aperto alternado nos implantes distais A e E, e quanto aos níveis de desajuste vertical, com todos os parafusos apertados com um torque de 10Ncm. As tensões geradas na área correspondente à região de crista óssea marginal em torno dos implantes foram avaliadas por meio de análise fotoelástica quantitativa empregando o método de compensação de Tardy. Após análise estatística dos resultados (p<0.05), verificou-se que, nos testes de passividade, o Ti cp apresentou resultados significantemente superiores de adaptação quando comparado as ligas de Co-Cr e Ni-Cr-Ti, as quais não apresentaram diferenças estatísticas entre si. O Ti cp foi semelhante à liga de Ni-Cr-Ti quanto aos níveis de desajuste vertical e tensões impostas aos implantes, com resultados superiores àqueles obtidos com a liga de Co-Cr. Foram aplicados testes de correlação entre as tensões fotoelásticas e os seguintes parâmetros: desajuste vertical, passividade média, adaptação marginal absoluta e percentual de redução de desajuste. Verificou-se correlação significante apenas entre os valores de adaptação marginal absoluta e tensões geradas pelas estruturas de Ni-Cr-Ti. Pode-se concluir que estruturas para próteses fixas sobre múltiplos implantes fundidas em monobloco podem produzir níveis biologicamente aceitáveis de desajuste, sendo os melhores resultados obtidos com o Ti cp, seguido das ligas de Ni-Cr-Ti e Co-Cr, respectivamente. Dentre os metais avaliados, a liga de Co-Cr transmitiu maiores níveis de tensões aos implantes. De um modo geral, não foram verificadas correlações entre valores de adaptação marginal e tensões impostas aos implantes. / Obtaining a good marginal fit of the prosthetic components is one of the main obstacles to the success of rehabilitation with implant-supported prostheses. It is not clear, in the literature, which misfit levels are considered clinically acceptable, but it is known that the absence of a perfect and passive fit may cause inadequate tensions on the osseointegration interface, which may bring about mechanical and biological problems. Photoelasticity is an experimental technique, used to analyze tensions, which is capable of producing results that are reliable to clinical parameters. When metal multiple-unit implant frames are cast in a single unit, it seems that obtaining a good marginal fit is even more critical. However, there are no studies in the literature about the influence that the type of metal or alloy used in these castings may have on the levels of prosthesis misfit. Thus, the present study has the aim to verify the marginal fit between the intermediate abutments and the one-piece structures cast with different materials; perform a photoelastic assessment of the tensions caused on implants when metal frames are fixed to them; and, research the possible correlations between the levels of marginal fit and the tensions generated on the interface implant-photoelastic material. To do this, 15 frames for implant-retained prostheses were waxed, using calcinable cylinders, simulating the positioning of five implants on the inter-mentalis region. The frames were divided into groups (n=5) and cast in a single piece with commercially pure titanium grade I, cobalt-chrome alloy, or nickel-chrome-titanium alloy. Marginal fit was assessed by optic microscopy, in terms of passivity, by a single screw test with alternate tightening on the distal implants A and E. As to the levels of vertical misfit, all screws were tightened to a torque of 10Ncm. Tensions generated in the area corresponding to the marginal bone crest region surrounding the implants were assessed by quantitative photoelastic analysis using the Tardy compensation method. After the statistical analysis of the results (p<0.05), it was verified that, in the passivity tests, the Ti cp showed significantly superior fitting results when compared to the Co-Cr and Ni-Cr-Ti alloys, which showed no statistically significant differences between them. In terms of the levels of vertical misfit and tensions over the implants, Ti cp was similar to the Ni-Cr-Ti alloy, showing superior results when compared to the Co-Cr alloy. Correlation tests were performed between the photoelastic tensions and the following parameters: vertical misfit, mean passivity, absolute marginal fit, and percentage of misfit reduction. A significant correlation was observed only between the values of absolute marginal fit and the tensions generated by the Ni-Cr-Ti frames. It is concluded that one-piece cast multiple-unit implant frames may produce biologically acceptable misfit levels, and the best results are obtained with Ti cp, followed by the Ni-Cr-Ti and Co-Cr alloys, respectively. Among the assessed metals, the Co-Cr alloy transmitted higher tension levels to the implants. In a general way, no correlations were observed between the values of marginal fit and tensions on implants.
69

Avaliação de próteses fixas sobre implantes com diferentes níveis de ajuste pilar/prótese: efeito da ciclagem termomecânica sobre diferentes parafusos protéticos e análise fotoelástica da transmissão de tensões / Evaluation of fixed implant-supported prostheses with different levels of abutment/prosthesis fit: the effect of thermomechanical cycling on different abutment screws and photoelastic analysis of stress transmission

Rafael Candido Pedroso e Silva 05 June 2012 (has links)
O objetivo deste estudo foi verificar os efeitos da ciclagem termomecânica sobre parafusos protéticos, convencionais de titânio e com cobertura de carbono, usados para fixação de próteses parciais fixas com desajuste de 150µm entre pilar e prótese, utilizando próteses sem desajuste como controle. Após ciclagem termomecânica das próteses, foram verificadas a adaptação marginal, a perda de torque dos parafusos protéticos e análise fotoelástica da distribuição de tensões ao redor dos implantes. Foram confeccionadas 12 próteses fixas sobre implantes, as quais foram divididas inicialmente em dois grupos (n=6): grupo 1 - sem desajuste (controle); grupo 2 - com desajuste simulado de 150&mu;m. Todas as próteses foram avaliadas em relação à adaptação marginal antes e após a simulação de ciclos mastigatórios. Os conjuntos foram submetidos a um total de 2.000.000 de ciclos mastigatórios, sendo que estes ensaios foram feitos duas vezes e os grupos iniciais foram subdivididos, na primeira vez foram utilizados parafusos com cobertura de carbono: grupo 1A (adaptadas) e grupo 2A (desadaptadas) e na segunda vez parafusos de titânio convencionais: grupo 1B (adaptadas) e grupo 2B (desadaptadas). A perda de torque dos parafusos foi analisada antes (T0), após 1.000.000 (T1) e 2.000.000 de ciclos (T2). A adaptação marginal após o ensaio melhorou significativamente ao se utilizar parafusos convencionais nas próteses adaptadas: pré-molar (p=0,001) e molar (p=0,028); e desadaptadas: pré-molar (p=0,014) e molar (p=0,007); mas ao se utilizar parafusos cobertos com carbono, a adaptação melhorou somente no pré-molar (p=0,015) das próteses desadaptadas. Quanto à perda de torque dos parafusos protéticos houve diferenças significantes antes e após a simulação dos ciclos mastigatórios entre as próteses adaptadas e desadaptadas, no molar, em todos os tempos para ambos parafusos (p&le;0,05); No pré-molar houve diferença significante apenas para os parafusos cobertos com carbono em T0 (p=0,019) e T2 (p=0,044). Quando comparados os parafusos, nas próteses adaptadas houve diferenças significantes no pré-molar em T1 (p=0,026) e T2 (p=0,043); e no molar em T2 (p=0,032); nas próteses desadaptadas houve diferenças significantes apenas para o pré-molar em T1 (p=0,046). Em relação à análise fotoelástica qualitativa, observou-se que em geral a aplicação de carga (10Kgf) gerou maior concentração e intensidade de tensões nas próteses desadaptadas, quando comparadas às adaptadas. Pode-se concluir que a simulação de ciclos mastigatórios teve influência sobre a adaptação marginal das próteses; em relação a perda de torque houve diferenças estatisticamente significantes entre as próteses adaptadas e desadaptadas; o tratamento de superfície dos parafusos foi eficaz apenas para próteses adaptadas, a análise fotoelástica sugere que próteses com desadaptações marginais provocam maior tensão ao redor dos implantes. / The objective of this study was to investigate the effects of thermomechanical cycling on prosthetic screws, conventional titanium and carbon coated, used for fixation of fixed partial dentures (FDP) with 150&mu;m of misfit between abutment and prosthesis, using fitted prostheses as control. After thermomechanical cycling of prostheses were verified, the marginal fit, the torque loss of prosthetic screws and the photoelastic analysis of stress distribution around implants. Twelve implant-supported fixed partial dentures were prepared and initially divided into two groups (n=6): group 1 - fitted prostheses (control), group 2 - 150&mu;m of simulated misfit. All prostheses had their marginal fit evaluated before and after simulation of cycles. The sets were subjected to a total of 2 million of cycles. Each group was assayed twice: in the first time, carbon coated screws were used: group 1A (fitted) and group 2A (misfitted); and in a second time, conventional titanium screws were used: group 1B (fitted) and group 2B (misfitted). The torque loss of the screws was analyzed before (T0), after 1,000,000 (T1) and 2,000,000 cycles (T2). Marginal fit improved significantly when using conventional screws in fitted prostheses: premolar (p=0,001) and molar (p=0,028), and in misfitted prostheses: premolar (p=0,014) and molar (p=0,007), but when using carbon coated screws, fit improved only in the premolar (p=0,015) of the misfitted prostheses. Torque loss of prosthetic screws were significantly different before and after simulation of the cycles between the fitted and misfitted, in molar, at all times for both screws (p&le;0,05); and in the premolar, were significant differences were noted only for the carbon coated screws at T0 (p=0,019) and T2 (p=0,044).When comparing the screws in the fitted prostheses, significant differences were noted in pre-molar at T1 (p=0,026) and T2 (p=0,043), and in the molar at T2 (p=0,032); whereas in the misfitted prostheses, significant difference was noted only for premolar at T1 (p=0,046). It was observed in qualitative photoelastic analysis that the load application (10Kgf) generated higher concentration and intensity of stresses in the misfitted prostheses, when compared to fitted ones. It can be concluded that the simulation of thermomechanical cycles had an influence on marginal fit of the prostheses. In relation to torque loss, differences between fitted and misfitted prostheses were noted, but the surface treatment of screws was effective only for fitted prostheses, and the photoelastic analysis suggests that prostheses with marginal misfit causes more stress around the implants.
70

Avaliação das tensões e do destorque de parafusos : influência do desajuste marginal e dos tipos de metais em infraestruturas protéticas retidas por implantes / Stress distribution and screw detorque analysis: : influence of misfit and alloy types in cast implant retained frameworks

Tramontino-Mesquita, Vanessa Silva, 1982- 02 October 2012 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T17:02:54Z (GMT). No. of bitstreams: 1 Tramontino-Mesquita_VanessaSilva_D.pdf: 1263598 bytes, checksum: 21599a6e0153542032add63750d48770 (MD5) Previous issue date: 2012 / Resumo: O objetivo neste estudo foi avaliar a distribuição das tensões geradas aos implantes modificados, por meio de análise extensométrica e força de destorque dos parafusos de retenção protética, de acordo com o tipo de metal da infraestrutura (Titânio comercialmente puro - Ti c.p ou Cobalto-Cromo - Co-Cr) e presença ou ausência de desajuste vertical padronizado. Um modelo metálico foi confeccionado, simulando uma mandíbula edêntula. Cinco análogos de pilares multi-unit foram fixados ao modelo metálico, posicionados de forma a reter uma prótese fixa total sobre implantes. Dez infraestruturas em titânio c.p. e 10 infraestruturas em Co-Cr foram obtidas através de fundição em monobloco. Cada infraestrutura originou dois modelos para mensuração, um adaptado e outro desadaptado em relação aos análogos. Para a obtenção dos modelos desadaptados, anéis metálicos de espessuras conhecidas (100, 200 e 300 ?m) foram posicionados entre a infraestrutura e seus análogos correspondentes. As infraestruturas foram distribuídas entre os grupos de tratamento (n=10): G1: Titânio adaptada; G2: Titânio desadaptada; G3: Co-Cr adaptada; G4: Co-Cr desadaptada. Em todos os casos, as infraestruturas foram fixadas aos análogos com torque de 10 N.cm com torquímetro digital. A força de destorque foi avaliada com torquímetro digital e o desajuste vertical, avaliado por meio de microscópio óptico (aumento de 120x), pelo teste do parafuso único. Extensometria foi utilizada para determinar as tensões geradas às fixações. As médias e desvio padrão de desajuste (?m) foram G1: 36,63 (15,84), G2: 174,45 (33,64), G3: 43,25 (14,06) e G4: 173,18 (24,45) (ANOVA e Tukey; alfa=5%), havendo diferença entre adaptados e desajuste, porém sem diferença entre Ti e Co-Cr. Não houve diferença entre os metais para tensão induzida aos implantes, mas maiores valores de desajuste promoveram maior tensão (ANOVA e Tukey; alfa=5%). Houve forte correlação positiva entre desajuste e tensão (Coeficiente de Correlação de Pearson, r=0,7475 e p<0,0001) e moderada correlação positiva entre desajuste e destorque (Coeficiente de Correlação de Pearson, r=0,3357 e p=0,0341). Para tensão e destorque, houve fraca correlação positiva (Coeficiente de Correlação de Pearson, r=0,2146 e p=0,1834). Pode-se concluir que próteses desadaptadas, independentemente do tipo de liga, promovem aumento nos valores de tensão aos implantes, mas não influenciam na força de destorque de parafusos protéticos / Abstract: This study evaluated stress induced on the implants using strain gauges analysis, and detorque loads of titanium prosthetic screws according to the type of the framework metal (c.p. Titanium or Cobalt-Chromium) and to the presence or absence of misfit. A metallic master model was fabricated, simulating an edentulous patient mandible. Five multi-unit abutment analogues were fixed on the master model, placed as though they would support a total fixed prosthesis. Ten c.p. titanium and 10 cobalt-chromium frameworks were obtained by 1-piece casting. Each framework created 2 measurement models, one passive fitted and the other misfitted to the analogues. To obtain the misfitted measurement models, metallic rings with known thickness (100, 200 and 300 ?m) were positioned between the framework and its analogues. Frameworks were distributed to treatment groups (n=10): G1: Titanium Passive Fit; G2: Titanium Misfit; G3: Cobalt-Chromium Passive Fit; and G4: Cobalt-Chromium Misfit. All infrastructures were screwed to their analogues using a digital torquimeter, with a torque of 10 N.cm. Detorque was assessed with a digital torquimeter, and misfit was evaluated by an optical microscope (120 X) according to the one-screw test. Strain gauges were used to determine stress generated on the fixations. Misfit mean values (?m) were G1: 36.63 (15.84), G2: 174.45 (33.64), G3: 43.25 (14.06) e G4: 173.18 (24.45), presenting difference between passive fit and misfit however no difference was found between the metals (ANOVA and Tukey; alfa=5%). There was no difference between materials for stress induced upon implants, but a higher level of misfit promoted higher values of stress (ANOVA and Tukey; alfa=5%). There was a strong positive correlation between fit and stress (Pearson's Correlation Coefficient, r=0.7475 and p<0.0001), and a moderate correlation between fit and detorque (Pearson's Correlation Coefficient, r=0.3357 and p=0.0341). For stress and detorque, there was a weak positive correlation (Pearson's Correlation Coefficient, r=0.2146 and p=0.1834). Misfitted prostheses, regardless of the metal type, promote high rates of stress to the implants, but do not influence the detorque of prosthetic screws / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Page generated in 0.1117 seconds