• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • 28
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 96
  • 96
  • 64
  • 60
  • 27
  • 18
  • 16
  • 16
  • 16
  • 16
  • 14
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Analise tridimensional da distribuição de tensões na estrutura do sistema barra/clips e interface osso/implante em função do tipo de material da barra e do desajuste vertical aos implantes / 3d analysis of stress distribuition on bar/clips structure and bone implant interface due to bar material and vertical misfit to dental implant

Abreu, Ricardo Teixeira 15 February 2007 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T05:13:45Z (GMT). No. of bitstreams: 1 Abreu_RicardoTeixeira_D.pdf: 11695187 bytes, checksum: 1c61217f27d7d7cc3554126159572197 (MD5) Previous issue date: 2007 / Resumo: Este trabalho verificou tridimensionalmente a distribuição de tensões na estrutura e interface osso/implante do sistema barra/clips sobre dois implantes osseointegrados quando influenciada pelo tipo de material da barra (Liga de Au tipo III, liga de AgPd, liga de CoCr e Ti cp) e por diferentes níveis de desajuste vertical da barra a um dos implantes (5Xm, 25Xm, 50Xm, 100Xm, 200Xm e 300Xm) utilizando a metodologia através dos elementos finitos. Com o uso do programa Rhinoceros® 3.0 (NURBS Modeling for Windows, EUA), foram modelados digitalmente dois implantes Máster Screw (Conexão, Brasil) de 10 mm de comprimento, 3,75 mm de diametro de rosca e 4,1 mm de plataforma; um sistema barra/clips com dois UCLAs sem anti-rotacional (Conexão, Brasil); e uma região anterior de mandíbula com severa reabsorção óssea. O conjunto modelado foi exportado para o programa NEiNastran® 9.0 (Noran Engineering Inc., EUA) onde foram realizadas as simulações mecânicas com carregamento de 20 N/cm durante o aperto dos parafusos de retenção da barra. Os resultados obtidos foram avaliados de forma qualitativa através do gradiente de cores das tensões de von Mises e quantitativamente através do registro de três nos que apresentaram maiores níveis de tensão, localizados na barra metálica (no 470), osso cortical (no 5581) e osso medular (no 10683). Na analise qualitativa foi possível observar uma redução de tensão localizada na porção mesial da região cervical, com aumento equivalente de tensão na porção distal da região cervical do osso cortical, osso medular e barra. Na analise quantitativa os maiores e menores níveis de tensão registrados no no 470 foram 1186 MPa no desajuste de 300Xm para a liga de CoCr e 03 MPa no desajuste de 5Xm para a liga de Au tipo III. Para o no 5581, foram registrados 255 MPa no desajuste de 5Xm para a liga de Au tipo III e 225 MPa no desajuste de 300Xm para a liga de CoCr. O no 10683 registrou 215 MPa no desajuste de 300Xm para a liga de CoCr e 201 MPa no desajuste de 5Xm para a liga de Au tipo III. Foi possível concluir que o modulo de elasticidade do material da barra e o desajuste influenciaram de forma significativa as tensões registradas na barra, sem, no entanto, apresentar grande influencia na tensão gerada na interface osso/implante / Abstract: This study evaluated the 3d stress distribution around a bar/clips overdenture system on two osseointegrated implants when influenced by bar material (type III Au alloy, AgPd alloy, cp Ti and CoCr alloy) and different vertical misfit to one of the implants (5Xm, 25Xm, 50Xm, 100Xm, 200Xm e 300Xm) using finite element methodology. Using Rhinoceros® 3.0 software (NURBS Modeling for Windows, EUA), there were digitally made two Master Screw implants (Conexao, Brazil) of 10 mm width, 3.75 mm thread diameter and 4.1 mm fit platform; a bar/clips overdenture system with two UCLAs (Conexao, Brazil); and an anterior part of a severed reabsorbed jaw. The modeled set was then exported to NEiNastran® 9.0 software (Noran Engineering Inc., EUA) where the mechanic simulations were made with the screw tightened to a torque of 20 N/cm. The obtained data were evaluated by qualitative and quantitative means. The qualitative analysis was evaluated by color scale given by the program. At this analysis waspossible to observe a stress reduction at the mesial portion of the cervical region, with equivalent raising stress of the distal portion of this same region, spongy bone and overdenture bar. The quantitative analysis was measured by von Mises stress registered on three knots that showed most stress on qualitative analysis. The three knots were located at the overdenture bar (knot 470), cortical bone (knot 5581) and spongy bone (knot 10683). The greatest and smallest stress levels recorded on knot 470 were 1186 MPa at 300Xm misfit for CoCr alloy and 03 MPa at 5Xm misfit for Au type III alloy. At knot 5581, there were registered 255 MPa at 5Xm for Au type III alloy and 225 MPa at 300Xm for CoCr alloy. The 10683 knot registered 215 MPa at 300Xm for CoCr alloy and 201 MPa at 5Xm for Au type III alloy. The elastic module of the overdenture bar and misfit influenced the stress distribution at the overdenture bar itself, although it did not have great influence at the bone/implant interface / Doutorado / Protese Dental / Doutor em Clínica Odontológica
52

Validação de uma máquina de testes de flexão rotacional e seus efeitos em implantes de hexágono externo e interno / Validation of a rotating bending machine and its effects on external and internal hexagon implants

Luiz Alves de Oliveira Neto 24 April 2013 (has links)
O sucesso do tratamento com implantes dentários depende do conhecimento teórico-prático do profissional, condições biológicas do paciente, e das propriedades mecânicas dos seus componentes. Dois testes de fadiga podem avaliar as propriedades mecânicas destes materiais: ensaios monotônicos unidirecionais e testes de flexão rotacional. A vantagem do dispositivo de flexão rotacional é o ensaio mais rápido que fornece dados relevantes e uma previsão mais realista da longevidade clínica. Oliveira-Neto (2011) avaliou o dispositivo de flexão rotacional desenvolvido por Ferreira (2010), e mostrou que componentes do dispositivo necessitavam ser revistos para assegurar melhor fixação do implante, controle de temperatura, frequência e permitir modificação do momento de força aplicado aos espécimes. O objetivo deste trabalho foi confeccionar e avaliar novos componentes para o dispositivo de flexão rotacional de Ferreira (2010) e avaliar seus efeitos em sistemas de implante de hexágono externo e interno. Os grupos testados foram: Aimplantes Hexagono Externo (HE) com munhão (UCLA); B- implantes HE com Pilar Cônico; C- implantes Hexagono Interno (HI) com munhão (UCLA); D- implantes HI com Pilar Cônico. O novo método consistiu em modificações no: porta implante, porta rolamento, centralizador do implante, material de fixação (resina acrílica). As amostras foram submetidas a ciclagem em torno do seu eixo longitudinal enquanto uma extremidade estava fixada em um mandril à 45o e a outra extremidade recebia a carga. O objetivo foi determinar o nível de carga em que 50% dos espécimes sobreviveram e 50% fraturaram antes de 106 ciclos girando a 16Hz. Assim, a resistência a fadiga (F50) foi determinada através da técnica staircase analysis. Após a ciclagem, os componentes que não apresentaram falhas tiveram o destorque de remoção mensurado eletronicamente, e todas as amostras foram analisadas através de microscópio eletrônico de varredura, radiografia e fotografia digital. Os resultados mostraram que os grupos UCLA têm maior resistência à fadiga. O sistema de HI-UCLA mostrou um desempenho mais estável, com uma resistência igual ao HE. Os grupos com Pilar Cônico apresentaram falhas clinicamente melhor, permitindo a substituição de componentes protéticos. Os danos mais graves ocorreram em ambos os grupos HE, com danos aos implantes. O método de desinclusão do implante da resina precisa ser revisto visando a obtenção de imagens sem artefatos. O dispositivo de Ferreira (2010) associado às modificações propostas por Oliveira-Neto permitiu a execução do ensaio de flexão rotativa em sistema de implantes com variadas configurações, produzindo resultados clinicamente relevantes. / Implant success depends on professional ability, patient biological conditions and also mechanical properties. Two fatigue tests can study implant mechanical properties: unidirectional bend-release fatigue testing and rotational fatigue testing. Advantages of rotational bending devices include faster tests that can generate relevant data and provide more realistic prediction of clinical performance. Oliveira- Neto (2011) evaluated a rotational bending device developed by Ferreira (2010), and showed its components need to be revised to ensure better implant fixation, temperature control, frequency and also enable to increase force moment. The aim of this study was fabricate and evaluate new components to Ferreiras device and it evaluate it effects in external and internal hexagon implant systems.Following groups were tested: A-external hex (EH) implants with UCLA abutment, B- EH implants with Conical Abutment, C- internal hex (HI) implants with UCLA abutment, D- IH implants with Conical Abutment. The new methodology consisted in changes on implant holder, bearing case, implant centralizer and bone material simulator (acrylic resin). Samples were spun around their long axes while being clamped into a 45o revolving collet on one end and loaded normal to their long axis on the other end. The aim was to determine the load level at which 50% of the specimens survived- and 50% fractured before 106 cycles at 16Hz. Fatigue resistance (F50) were determined using the staircase procedure. After cycling, torque of survival components were measured electronically, and all samples were analyzed by scanning electron microscopy, x-ray and digital photography. Results showed that UCLA groups have higher fatigue resistence. The IH-UCLA system showed more stable performance, with equal resistance to EH. Conical Abutment groups failure clinically better, allowing replacement of prosthetic components. The most severe damage occurred in both EH groups, with implant damages. Ferreiras device with Oliveira-Neto changes enabled to perform a rotating bending test on implant system in numerous configurations, producing clinically relevant results.
53

Uso de sacaffolds de Poli L Lactide e de Poli L Lactide com hidroxiapatita em calota craniana : modelo experimental em ratos Wistar / Use of sacaffolds of Poly L Lactide and Poly L Lactide with hydroxyapatite in skullcap : experimental model in Wistar rats

Basso, Rafael de Campos Ferreira, 1974- 24 August 2018 (has links)
Orientador: Paulo Kharmandayan / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-24T15:54:40Z (GMT). No. of bitstreams: 1 Basso_RafaeldeCamposFerreira_M.pdf: 2923257 bytes, checksum: a229be9baca0180070629eab5f5e76d1 (MD5) Previous issue date: 2014 / Resumo: O tratamento de deformidades no corpo humano, principalmente deformidades ósseas craniofaciais, sejam elas causadas por trauma, infecções, deformidades congênitas ou pós exerese tumorais, continua sendo, nos dias atuais, um grande desafio ao cirurgião. Sabe-se que os enxertos de tecidos autólogos são o padrão ouro para essas reparações, porém, é notável a escassez de áreas doadoras. Nos últimos anos, com o avanço da engenharia de tecidos usando cultura de células semeadas em implantes, tem aumentado vertiginosamente a procura por polímeros biorreabsorvíveis que possam ser considerados ideais para fabricação de moldes, conhecidos cientificamente como scaffolds, carreadores de células capazes de recompor defeitos causados por perdas teciduais. O presente experimento objetiva estudar, experimentalmente, o uso de placas de Poli L Lactide (PLLA) e Poli L Lactide associada à Hidroxiapatita (PLLA + HA), obtidas por rotofiação (rotary jet spinning), como uma possibilidade de oferecer scaffolds de boa qualidade para colaborar com o avanço da engenharia tecidual. Para isso, utilizou-se 30 ratas da raça Wistar, distribuídas em 3 grupos,nas quais foram realizados defeitos críticos na calota craniana. Em seguida foram implantados scaffolds de PLLA e PLLA + HA e comparados com o grupo controle, que não recebeu implante. Os resultados mostraram que nos casos em que apenas foram realizados os defeitos nas calotas cranianas, não ocorreram a cicatrização óssea. Nos casos em que os scaffolds de PLLA e de PLLA + HA foram usados, notou-se rica neovascularização, acompanhada de reação do tipo corpo estranho e presença de osso reativo ao redor dos implantes / Abstract: The treatment of deformities in the human body, especially craniofacial bone deformities, whether caused by trauma, infection, congenital or due to resection tumors, remains, nowadays, a great challenge to the surgeon. It is known that autologous tissue grafts is the gold standard for these repairs, however, it is remarkable the scarcity of donor areas. During the last years, with the improvement of tissue engineering using cell culture growth in implants, has increased dramatically the search for an ideal polymer that can be used as a mold, known as scaffolds, for cell attachment and thus enabling the recomposition of defects caused by tissue loss. The present experiment aims to study experimentally the use of Poly L-Lactide(PLLA) plates and Poly L-Lactide(PLLA) associated with Hydroxyapatite (HA), obtained by Rotary Jet spinning, as a possibility to provide scaffolds with good quality and affordable costs to collaborate with the tissue engineering advancement. For this, were used 30 Wistar rats, distributed into 3 groups, in which critical defects were performed in the skull. Then scaffolds of PLLA and PLLA + HA (groups 2 and 3) were implanted and compared with the control group that didn¿t receive implant (group 1). The results have shown that in cases where only the defects in cranial caps were done, bone healing have not occurred. In cases where the scaffolds of PLLA and PLLA+ HA were used, rich neovascularization was noted, accompanied by foreign body type reaction and presence of reactive bone around the implants / Mestrado / Fisiopatologia Cirúrgica / Mestre em Ciências
54

A influência da ciclagem mecânica sobre o desajuste marginal, tensão e torque de afrouxamento no sistema implantossuportado = Influence of mechanical cycling on marginal misfit, strain and loosening torque in the implant-supported system / Influence of mechanical cycling on marginal misfit, strain and loosening torque in the implant-supported system

Marques, Isabella da Silva Vieira, 1986- 23 August 2018 (has links)
Orientadores: Marcelo Ferraz Mesquita, Jessica Mie Ferreira Koyama Takahashi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T00:57:52Z (GMT). No. of bitstreams: 1 Marques_IsabelladaSilvaVieira_M.pdf: 2460672 bytes, checksum: c23d88013ae75d0941f8cc574887e9dc (MD5) Previous issue date: 2013 / Resumo: O objetivo neste estudo foi avaliar a influência da ciclagem mecânica no torque de afrouxamento de parafusos protéticos, no desajuste marginal e na transmissão de tensões ao sistema prótese-implante. Foram confeccionadas 10 infraestruturas metálicas fundidas em titânio comercialmente puro, simulando próteses parciais fixas (PPF) de três elementos retidas por dois implantes e próteses totais fixas (PTF) retidas por cinco implantes. A partir das infraestruturas enceradas e fundidas, foram confeccionados modelos que deram origem aos 3 grupos de avaliação (n = 10): grupo I (pré-fundição), grupo II (adaptado) e grupo III (desajuste simulado), tanto para a PPF quanto para a PTF. Para cada modelo de trabalho (resina) confeccionado, foram avaliados o desajuste marginal e torque de afrouxamento, antes e após a ciclagem mecânica (1 milhão de ciclos mecânicos, 2 Hz, 280 N). Os torques de afrouxamento iniciais dos parafusos protéticos e dos parafusos de mini abutments foram mensurados 24 horas após a aplicação do torque (10 Ncm e 20 Ncm, respectivamente) utilizando um torquímetro digital. O teste do parafuso único foi realizado e o desajuste vertical foi quantificado por meio de microscópio óptico. As tensões geradas aos análogos durante a fixação da infraestrutura foram avaliadas em um modelo de gesso utilizando strain gauges, sendo cada infraestrutura parafusada ao modelo com um torque padronizado de 10 Ncm. Os resultados obtidos foram submetidos à análise exploratória seguida dos testes estatísticos ANOVA e Tukey (? = 0,05) quando obtidos dados paramétricos e Mann Whitney e Wilcoxon quando encontrados dados não paramétricos. Para todos os grupos avaliados, a ciclagem mecânica não apresentou diferença significativa quando analisados torque de afrouxamento dos parafusos protéticos, desajuste e tensão, porém houve um aumento nos valores médios de torque de afrouxamento dos mini abutments nos grupos II e III para a PPF e no grupo III para a PTF. O teste de correlação de Pearson (? = 0,05) indicou correlação positiva entre desajuste e tensão para todas as situações avaliadas e ainda correlação negativa entre torque de afrouxamento e desajuste vertical, para os grupos II e III de ambos os designs protéticos. Dentro das condições avaliadas e resultados obtidos, pode-se concluir que a ciclagem mecânica de infraestruturas de próteses múltiplas parafusadas não exerce influência relevante sobre o torque de afrouxamento, desajuste e tensão. Os parafusos protéticos apresentam maior tendência ao afrouxamento em próteses mal adaptadas. Próteses desadaptadas geram maior tensão ao sistema prótese-implante / Abstract: The aim of this study was to evaluate the influence of cyclic loading on loosening torque, misfit and strain transmitted to prosthesis-implant system. Ten Commercially pure titanium frameworks were casted simulating fixed partial dentures (FPD) of three elements retained by two implants and mandibular full-arch fixed prostheses (FFP) as bars retained by five implants. From the waxed and casted frameworks, models were fabricated, which resulted in three evaluation groups (n = 10): group I (pre-casting), group II (passive fit) and group III (simulated misfit), for both prosthetic designs. For each fabricated acrylic resin cast, the misfit and loosening torque analyses were assessed before and after mechanical loading (106 mechanical cycles, 2 Hz, 280 N). The initial prosthetic and mini abutment screws loosening torque were measured 24 hours after the tightening torque (10 Ncm and 20 Ncm, respectively) using a digital torque meter. The single-screw test was performed and the vertical misfit was quantified using an optical microscope. The strain after fixation was evaluated in a plaster cast using strain gauges analysis with each framework tightened to the cast with 10 Ncm standardized torque. The results were submitted to exploratory analysis followed by statistical tests such as ANOVA and Tukey (? = 0.05) when parametric data were found and Mann-Whitney and Wilcoxon when non-parametric data were obtained. For all groups, the cyclic loading had no significant difference when analyzed the prosthetic screw loosening torque, misfit and strain, but there was an increase of the mini abutment loosening torque mean values for FPD of groups II and III and for FFP of group III. The Pearson correlation test (? = 0.05) indicated a positive correlation between misfit and strain for all evaluated situations and a negative correlation between loosening torque and vertical misfit for both prostheses designs of groups II and III. Within the evaluated conditions and obtained results, it can be concluded that cyclic loading of screw-retained multiple prosthesis does not exert significant influence on loosening torque, misfit and strain. The prosthetic screws have a greater tendency to loosening in ill-fitting prosthesis, which induces higher strain values on prosthesis-implant system / Mestrado / Protese Dental / Mestra em Clínica Odontológica
55

Efeito da ciclagem mecânica e da técnica de fundição sobre o desajuste marginal, tensão e torque de afrouxamento de infraestruturas de próteses múltiplas implantossuportadas = Effect of cyclic loading and casting technique over marginal fit, strain and loosening torque on frameworks of multi-unit implant-supported prostheses / Effect of cyclic loading and casting technique over marginal fit, strain and loosening torque on frameworks of multi-unit implant-supported prostheses

Bhering, Cláudia Lopes Brilhante, 1989- 21 June 2013 (has links)
Orientadores: Marcelo Ferraz Mesquita, Jessica Mie Ferreira Koyama Takahashi / Dissertação (mestrado profissional) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T08:00:41Z (GMT). No. of bitstreams: 1 Bhering_ClaudiaLopesBrilhante_M.pdf: 2599454 bytes, checksum: bd13164e8616791d20fc97e7001d9fc7 (MD5) Previous issue date: 2013 / Resumo: Este estudo teve como objetivo avaliar a influência do processo de fundição e da ciclagem mecânica sobre o desajuste marginal, tensão e torque de afrouxamento de próteses múltiplas implantossuportadas. Infraestruturas de prótese parcial fixa (PPF) suportada por dois implantes e prótese total fixa (PTF) suportada por cinco implantes foram enceradas usando cilindros de mini pilar totalmente calcináveis ou sobrefundidos (n=10). A partir das infraestruturas enceradas, os modelos de trabalho foram confeccionados utilizando análogos de implante (Hexágono Externo - 4.1mm) parafusados a mini pilares e um índex de gesso foi confeccionado utilizando análogos modificados de mini pilar. Quatro grupos foram obtidos de acordo com o tipo de prótese (PPF ou PTF) e cilindro protético (calcinável ou sobrefundido) avaliado. As infraestruturas foram fundidas em liga de CoCr e os parafusos apertados com 20Ncm (mini pilar) e 10Ncm (protético) utilizando torquímetro digital. Após 24 horas, o torque de afrouxamento e o desajuste inicial foram avaliados. O desajuste foi aferido por meio do teste do parafuso único. A análise de tensão foi realizada por meio de strain gauges colados na superfície dos análogos modificados, formando ¼ de ponte de Wheatstone. Os parafusos foram reapertados e as amostras submetidas a 106 de ciclos mecânicos (2Hz/280N). As mensurações finais foram realizadas e os resultados submetidos à Anova - 2 fatores/Teste de Tukey HSD e correlação de Pearson (?=0,05). Não houve diferença no desajuste para todos os intervalos de tempo e grupos avaliados no índex de gesso (p>0,05). As infraestruturas sobrefundidas apresentaram maior tensão que as obtidas com cilindros calcináveis (PPF: Inicial p=0,0047; Final p=0,0004; PTF: Inicial p=0,0476; Final p=0,0115). Não houve influência da ciclagem mecânica na tensão (p>0,05). No modelo de trabalho, as PPFs confeccionadas com cilindros calcináveis apresentaram maior desajuste que as sobrefundidas (Inicial: p=0,0005; Final: p=0,0007). As PTFs apresentaram desajuste similar (p>0,05). A ciclagem mecânica não influenciou o desajuste em ambos os modelos avaliados (p>0,05). Os parafusos de mini pilar das PTFs sobrefundidas apresentaram menor torque de afrouxamento que o grupo calcinável após a ciclagem mecânica (p=0,0024). Os parafusos protéticos dos grupos calcináveis apresentaram menor torque de afrouxamento que os sobrefundidos no tempo final (PPF: p=0,0013; PTF: p=0,0064). O torque de afrouxamento dos parafusos protéticos das PPFs calcináveis diminuiu após a ciclagem mecânica (p=0,0044). Correlação negativa foi observada entre o desajuste e o torque de afrouxamento dos parafusos protéticos (PPF: r=-0,49523 p=0,0012; PTF: r=-0,31423 p=0,0483). Não houve correlação entre o desajuste e a tensão (PPF: r=0,24 p>0,05; PTF: r=0,21 p>0,05). Conclui-se que o benefício do cilindro utilizado em relação à adaptação depende do tipo de prótese e componente sobre o qual o desajuste é avaliado. Próteses confeccionadas com cilindros sobrefundidos geram maior tensão e apresentam maior estabilidade dos parafusos protéticos. A ciclagem mecânica não influencia o desajuste e a tensão de próteses múltiplas, mas reduz o torque de afrouxamento em infraestruturas com maior desadaptação. Não existe correlação entre desajuste vertical decorrente da fundição e a tensão. Contudo, há correlação entre o desajuste marginal e o torque de afrouxamento dos parafusos protéticos mediante a ação de forças dinâmicas / Abstract: This study aimed to evaluate the influence of casting and cyclic loading on marginal misfit, strain and loosening torque of multiple implant-supported prostheses. Fixed partial dentures (FPD) frameworks supported by two implants and fixed full-arch dentures (FAD) frameworks supported by five implants were waxed using overcasted or calcinable mini abutment cylinders (n=10). The models were obtained with external hexagon implant analogs and mini abutments fixed to waxed frameworks. A plaster index was obtained using mini abutment modified analogs for strain gauge analysis. Four groups were obtained according to prosthesis (FPD or FAD) and cylinder (calcinable or overcasted) type. The frameworks were casted in CoCr alloy. The abutment and prosthetic screws were tightened with 20Ncm and 10Ncm, respectively, using digital torque meter. After 24 hours, initial loosening torque and marginal misfit were evaluated. The misfit readings were performed following the single screw test protocol. The prosthetic screws were tightened with 10Ncm and strain analysis performed by strain gauges bonded at the mini abutment analogs surface forming a ¼ of Wheatstone bridge. The screws were retightened and the samples submitted to 106 mechanical cycles (2Hz/280N). The final measurements were performed and the results submitted to 2 way - Anova/Tukey's HSD Test and Pearson Correlation Test (?=0.05). No difference was found in marginal misfit on all time intervals and groups on the plaster index (p>0.05). The frameworks manufactured with overcasted cylinders presented higher strain than calcinables ones, regardless of prosthesis type and time evaluated (FPD: Initial p=0.0047; Final p=0.0004; FAD: Initial p=0.0476; Final p=0.0115). No difference was observed in strain before and after cyclic loading (p>0.05). Considering the resin model, the calcinable FPD groups presented higher marginal misfit than overcasted ones (Initial: p=0.0005; Final: p=0.0007). Similar marginal misfit was noted among FAD groups (p>0.05). The cyclic loading did not affect the marginal misfit (p>0.05) in both evaluated models. The overcasted FADs abutment screws showed lower loosening torque than calcinable ones after cyclic loading (p=0.0024). The prosthetic screws of calcinable frameworks presented lower loosening torque than the overcasted at final measurement (FPD: p=0.0013; FAD: p=0.0064). After cyclic loading, the prosthetic screw loosening torque of calcinable FPDs decreased (p=0.0044). Negative correlation was observed between marginal misfit and loosening torque of prosthetic screws (FPD: r=-0.49523 p=0.0012; FAD: r=-0.31423 p=0.0483). No correlation was observed between misfit and strain (FPD: r=0.24 p>0.05; FAD: r=0.21 p>0.05). It is concluded for marginal fit, the benefit of the cylinder type depends on prosthesis design and component evaluated. Overcasted components generate higher strain and screw stability than totally calcinable ones. The cyclic loading did not influence misfit and strain of multiple-unit prostheses, but decreased the screw loosening torque in poorly fitted frameworks. There was no correlation between marginal misfit resulted from casting and strain induced on the system. There was correlation between marginal misfit and prosthetic screw loosening torque when submitted to cyclic loading / Mestrado / Protese Dental / Mestra em Clínica Odontológica
56

The effect of platform connection and abutment material on stress distribution in single anterior implant-supported restoration = a 3D finite element analysis = A influência do material e conexão de pilares na distribuição de tensões em coroas anteriores sobre implantes: um estudo pelo método dos elementos finitos / A influência do material e conexão de pilares na distribuição de tensões em coroas anteriores sobre implantes : um estudo pelo método dos elementos finitos

Carvalho, Marco Aurélio de, 1989- 23 August 2018 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T17:33:02Z (GMT). No. of bitstreams: 1 Carvalho_MarcoAureliode_M.pdf: 8351585 bytes, checksum: 5577f7f5bed23cd367f52fac8602f7af (MD5) Previous issue date: 2013 / Resumo: A reabilitação de elementos unitários com implantes osseointegrados na região anterior da maxila é um cenário desafiador diante dos requisitos estéticos e funcionais. Nesse contexto, diferentes tipos de conexões pilar/implante e materiais constituintes do pilar surgiram no intuito de suprir as exigências estético-funcionais atuais. A distribuição de tensão no sistema de restaurações cimentadas a pilares cerâmicos parafusados a implantes é um fator importante na elucidação do processo de falha e também na previsibilidade de sucesso do tratamento. O objetivo do trabalho foi avaliar o efeito de diferentes conexões e materiais de pilar na distribuição de tensões em restaurações sobre-implante unitárias anteriores através do método dos elementos finitos. Foram obtidos 9 grupos experimentais a partir da combinação de três conexões protéticas (hexagonal externa-HE, hexagonal interna-HI e cone morse-CM) e três tipos de material constituinte do pilar (titânio-Ti, zircônia-Zr e híbrido-H): HETi, HEZr, HEH, HITi, HIZr, HIH, CMTi, CMZr, CMH. Com o auxilio do software de modelagem 3D (SolidWorks 2012 Corp., Concord, MA, EUA), foram obtidos os modelos geométricos que se constituíam de: segmento anterior de maxila; implantes HE, HI e CM construídos a partir do implante Titamax Ex 4x13mm (Neodent, Curitiba, Brasil); pilar do tipo Munhão Anatômico CM (Neodent, Curitiba, Brasil) em titânio, zircônia e híbrido (corpo em zircônia e base em titânio) para implantes HE, HI e CM; coroa do elemento 21 em dissilicato de lítio cimentada com cimento resinoso. Foi aplicada uma carga, de 49N em 45 graus em relação ao longo eixo do dente, de forma contínua em 6 etapas desde a região de cíngulo à borda incisal, no intuito de simular o movimento de excursão da guia incisal. O critério de Tensão Equivalente de von Mises (?vM) foi utilizado para a avaliação quantitativa e qualitativa dos implantes e pilares entre os nove grupos. As tensões máxima (?max) e mínima (?min) principais foram utilizadas para a avaliação quantitativa entre os pilares de zircônia e corpo de zircônia de pilares híbridos. Os maiores valores de ?vM (MPa) para o pilar foram encontrados nos grupos CMZr, CMH e CMTi (315,61; 293,61; 289,36 respectivamente), e os menores nos grupos HEH, HITi e HIH (91,70; 97,58; 100,65, respectivamente). Os valores ?max e ?min foram menores nos grupos H que nos Zr. Qualitativamente, a concentração de tensão se deu na interface pilar/implante em todos os grupos, independente da conexão ou material do pilar. Concluiu-se que o tipo de conexão teve maior influência que o material constituinte nas tensões acumuladas nos pilares, sendo que os pilares híbridos tiveram comportamento mecânico semelhante aos de titânio, que por sua vez foi melhor que os pilares em zircônia / Abstract: The anterior single crown reconstruction is still a challenging scenario in implant dentistry. Within the esthetic and functional demand, different platform connections and abutment material emerged for better outcomes. The stress distribution through the structure is an important factor to be elucidated for better fail process understanding and also to the treatment success predictability. Therefore, the aim of this study was to evaluate the effect of different abutment material and platform connection on stress distribution in single anterior implantsupported restorations, through the finite element method. Nine experimental groups were design from the combination of three platform connection (external hexagon-EH, internal hexagon-IH and morse tapered-MT) and three abutment material (titanium-Ti, zirconia-Zr and hybrid-H): EHTi, EHZr, EHH, IHTi. IHZr, IHH, MTTi, MTZr, MTH. Finite element models were obtained with the aid of a modeling software (SolidWorks 2012 Corp., Concord, MA, USA), and consisted of: EH, IH and MT implants modeled from Titamax Ex 4x13mm (Neodent, Curitiba, Brazil); abutment modeled from Anatomic Abutment CM (Neodent, Curitiba, Brazil) in titanium, zirconia and hybrid (two-piece abutment); lithium disilicate central incisor crown cemented over the abutment. The occlusal loading, consisted of a magnitude of 49N in 45 degrees to the implant long axis, was applied in six steps in order to simulate the incisal guidance. The equivalent von Mises criterion (?vM) was used for both qualitative and quantitative evaluation of implant and abutment among all groups. The maximum (?max) and (?min) minimum principal stresses were obtained for numerical comparison of zirconia abutment and zirconia abutment body. The highest abutment ?vM (MPa) occurred in MTZr, MTH and MTTi (315.61; 293.61; 289.36 respectively); and the lowest in EHH, IHTi and IHH (91.70; 97.58; 100.65, respectively). The ?max and ?min values were lower in H groups than Zr groups. The stress distribution concentrated in the abutment/implant interface in all groups, regardless the platform connection or abutment material. It was concluded that the platform connection had more influence than abutment material on stress values and distribution on abutments, and the stress values for implants were similar among different platform connections, but greater stress concentrations were observed in internal connections / Mestrado / Protese Dental / Mestre em Clínica Odontológica
57

Desenvolvimento de bionanocompósitos Poli(álcool vinílico)-Poliuretano/Hidroxiapatita para enxerto maxilo facial / Poly(vinyl alcohol)-Polyurethane/Hydroxyapatite bionanocomposites development for facial maxillo graft

Andrade, Sabina da Memoria Cardoso de, 1955- 20 August 2018 (has links)
Orientadores: Cecília Amélia de Carvalho Zavaglia, Carmen Gilda Barroso Tavares Dias / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-20T18:23:16Z (GMT). No. of bitstreams: 1 Andrade_SabinadaMemoriaCardosode_D.pdf: 7127568 bytes, checksum: 0ebd83d085ffff7fe81cf8749ab309fb (MD5) Previous issue date: 2012 / Resumo: A coesão de um grupo de profissionais de diversas áreas onde haverá troca de informações para a concretização de um biomaterial é fator decisivo para reunir todos os requisitos necessários de caracterizações físicas, químicas e biológicas e assim garantir biocompatibilidade e biofuncionalidade, associadas à interação entre o tecido vivo e o biomaterial. Scaffold biodegradável que combina a bioatividade de hidroxiapatita (HA) e a degradabilidade ajustável de matriz de poliuretano (PU) obtido a partir do PVAl foi desenvolvido nesta pesquisa e submetido à caracterizações morfológicas, mecânicas e biológicas. Este novo tipo de scaffold não é tóxico, apresenta interconexão de poros e microporos nas paredes dos poros, boa resistência mecânica e boa ativação de crescimento celular, propriedades que satisfazem as exigências do uso clínico. As análises através de microscopia eletrônica de varredura mostram além da conexão de poros as nanopartículas de hidroxiapatita distribuídas de maneira uniforme na matriz do bionanocompósito. Os valores médios de resistêcia à compressão da matriz e do bionanocompósito foram próximos de 60 MPa tanto para PVAl-PU como para PVAl-PU/HA com 25% de HA, e 105 MPa PVAl-PU/HA com 33% de HA. Após 24 horas de implante o biomaterial PVAl-PU/HA já apresentou em observação por MEV, detalhe de células aderidas, sugestivas provavelmente de células de fibroblasto, espraiamento com formação de uma camada celular compacta e homogênea e após 14 dias do implante foi observada a interação do biomaterial com as camadas do tecido subcutâneo e a invasão do crescimento celular pelos poros interconectados do scaffold. Portanto o scaffold desenvolvido neste trabalho é indicado com expectativas promissoras para implantes ósseos / Abstract: The cohesion of a group of professionals from many areas, exchanging information to concretize a bio material, is a crucial factor to gather all of the requirements of physical, chemical, and biological characterization and therefore ensure biocompatibility and bio functionality, associated to the interaction of the living tissue and the biomaterial. In this research it was developed and subjected to morphological, mechanical and biological characterization, a biodegradable scaffold that combines the bioactivity of hydroxyapatite (HA) and the adjustable degradability of polyurethane matrix (PU) obtained from the PVA1. This new kind of Scaffold is non toxic, has interconnected pores and micropores at the pore's wall, great mechanical resistance and great cellular growing activation. These properties meet the clinical use requirements. The scanning electronic microscopy analysis shows, beside the pore connection, the hydroxyapatite microparticles arranged evenly in the bionanocomposite. The medium values of compression resistance of the matrix and of the bionanocomposite were close to 60 MPa for PVA1-PU well as PVA1-PU/HA with 25% of HA, and 105 MPa PVA1-PUH/HA with 33% of HA. After 24 hours of insertion, the biomaterial PVA1-PU/HA presented as seen in MEV observation, adherent cells, probably coming from fibroblast cells, spreading with a cellular compact and homogeneous layer and, after 14 days of the insertion, it was observed the biomaterial interaction with the layers of the subcutaneous tissue and the invasion of the cellular growing through the scaffold's interconnected pores. Therefore, the osseous scaffold is indicated with promissing expectations to implants / Doutorado / Materiais e Processos de Fabricação / Doutora em Engenharia Mecânica
58

Bone–Biomaterial Interface:the effects of surface modified NiTi shape memory alloy on bone cells and tissue

Muhonen, V. (Virpi) 17 June 2008 (has links)
Abstract Whenever a foreign material is implanted into a human body an implant–tissue interface area forms between them. In this microenvironment, interactions take place between the implant and the surrounding tissue. The implantation of a biomaterial into tissue results in injury and initiation of the inflammatory response. This host response to biomaterials is an unavoidable series of events that occur when tissue homeostasis is disturbed by the implantation process. In bone tissue, biocompatible implants must initially be capable of strong bone implant contact and subsequently, allow the normal bone remodeling cycle around the implant. NiTi is a metal alloy composed of approximately a 50:50 ratio of nickel and titanium. It possesses shape memory and superelasticity properties, which make it an interesting biomaterial. NiTi has two phases: austenite and martensite. A decrease in temperature or applied stress induce the austenite-to-martensite transformation. Heating or removing the stress restores the parent austenite phase. The alloy in its martensite structure can be reshaped and strained several times more than a conventional metal alloy without irreversible deformation of the material. The alloy returns to its original shape as it changes from martensite-to-austenite. This transformation is seen as the macroscopic shape memory effect. This study further investigated the biocompatibility of NiTi, especially the bone cell response to both austenite and martensite. Different surface treatments were investigated in order to improve and possibly even control NiTi's bioactivity as a bone implant material. Osteoclasts grew and attached well on the austenite NiTi phase, but the results indicated that the biocompatibility of martensite NiTi was compromised. Oxidation of the NiTi surface improved osteoblast attachment and viability. This was due to the formation of a TiO2 surface layer of moderate thickness. Coating the NiTi surface with the extracellular matrix protein fibronectin was shown to enhance osteoblast proliferation and increase the number of cells in the G1 cell cycle stage. Austenite was more prone to show these effects than martensite. A sol-gel derived titania-silica surface treatment was observed to increase the bone implant contact of functional NiTi intramedullary nails. The surface treatment was most effective with the constant bending load provided by the NiTi nail.
59

Avaliação da manutenção da pre-carga de parafusos de ouro e titanio em proteses implanto-suportadas / Pre-load maintenance in abutment and prosthetic screws implant restoration after simulated load cycling: an in vitro study

Panza, Leonardo Henrique Vadenal, 1982- 12 January 2006 (has links)
Orientador: Altair Antoninha Del Bel Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-07T21:11:17Z (GMT). No. of bitstreams: 1 Panza_LeonardoHenriqueVadenal_M.pdf: 663328 bytes, checksum: 9c68a1e736e333278ff91bfba5ca2da4 (MD5) Previous issue date: 2006 / Resumo: O sucesso da terapia reabilitadora com implantes requer um equilíbrio entre fatores biológicos e mecânicos. Os fatores biológicos são multifatoriais, já os mecânicos associam-se à instabilidade da conexão implante-parafuso-intermediário. Entre os fatores responsáveis pela manutenção da estabilidade desta conexão, a manutenção da pré-carga do parafuso é o mais importante. Com base nestas informações, este estudo buscou avaliar a manutenção da pré-carga de parafusos de ouro, após a aplicação de carga simulada, por meio da realização de ciclagem mecânica do conjunto protético, e também observar a ocorrência de rotação da coroa ou do intermediário protético em relação aos implantes. Para tanto, foram utilizados 40 implantes, 20 com hexágono interno e 20 externo, conectados a intermediários protéticos do tipo Esteticone com angulação de 17° e sem angulação, todos retidos por parafusos de titânio rosqueados a 20N/cm, sobre os quais foram parafusadas coroas confeccionadas em resina acrílica simulando pré-molares superiores humanos com parafusos de ouro apertados a 10N/cm. Cada conjunto foi então submetido ao ensaio de fadiga com aplicação de forças médias de 115 N no sentido do longo eixo do implante por 0.2 s, com uma freqüência de 1 Hz, totalizando um total de 250.000 de ciclos (correspondendo aproximadamente a 3 meses de uso). A manutenção da pré-carga dos parafusos, foi avaliada pelo destorque dos parafusos, após a realização do ensaio de fadiga, com a utilização de um torquímetro digital. Os resultados foram então submetidos à análise de variância a 2 critérios e ao teste de Tuckey, através dos quais foi possível observar que, para o parafuso protético, ocorreu diferença estatisticamente significante entre os tipos de implante, mas sem interação com o tipo de intermediário. No entanto para o parafuso do intermediário ocorreu diferença significativa tanto para o tipo de implante como entre os intermediários, com interação entre os fatores. A análise estatística apontou um desempenho melhor para a manutenção da pré-carga inicial dos parafusos, nos intermediários angulados tanto nos implantes de hexágono interno, quanto nos de hexágono externo. Nenhum dos corpos de prova apresentou rotação de coroa ou intermediário protético quando analisados ao microscópio / Abstract: After osseointegration failures, screw loosening is the most common problem in implant dentistry. However, controversies still exist regarding to the influence of type connection implant to abutment in screw loosing or fracture. This study evaluated pre-tightening maintenance in abutment and prosthetic screws of external and internal implant hexagon with standard and 17° angulated abutments after fatigue testing. Also, the rotational dislodgement was checked using digital measurement microscope. Four subsets (n=10) of implants and abutments were assessed: (G1) internally hexed implant and standard abutment (G2) internally hexed implant and 17° angulated abutment (G3) externally hexed implant and standard abutments (G4) externally hexed implant and 17° angulated abutment. Abutments were retained by titanium screws tightened to 20 N/cm. Acrylic resin crowns were manufactured and were retained over the abutments with gold screws tightened at 10 N/cm, using an electronic torque controller. A vertical line was ascribed across the implant-abutment and crown-abutment interface to identify any rotational displacement. The fatigue tests were performed in a servo-hydraulic machine which delivered forces between 100 and 120 N for 250,000 cycles, through a piston to the crown. The implant-abutment interface were evaluated using a light microscope. Then, screw was removed and detorque value was recorded. Data were statistically analyzed using ANOVA and Tukey test (a=.05) No horizontal displacement of acrylic resin crown and abutments were observed. ANOVA showed significant difference for prosthetic screw between implant types, but without interaction with abutment. However, for abutment screw, there was a significant difference between implant type and abutment. Also, it was observed interaction between implant and abutments types. Internally hexed implants (G1 and G2) and externally hexed implants (G3 and G4) showed significant difference with a better performance for angulated abutment in comparison to standard abutment. Within the limitations of this study it was concluded that pre-tightening maintenance of screw was affected by the type of abutment and the type connection implant used. There was no dislodgement for crown or abutment when standard or pre-angulated abutments were used after 250.000 cycles of simulated loading. Indeed, internal and external hexed connections were effective to avoid rotation of crowns / Mestrado / Protese Dental / Mestre em Clínica Odontológica
60

Análise da resposta pró-inflamatória de macrófagos cultivados em substratos contendo nanotubos de carbono de parede múltipla (MWCNTs) / Analysis of the pro-inflammatory response of macrophage grown in substrate containing carbon nanotubes multi-wall (MWCNTs)

Paula, Mirian Michelle Machado de, 1988- 26 August 2018 (has links)
Orientadores: Marcus Alexandre Finzi Corat, Anderson de Oliveira Lobo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-26T10:38:02Z (GMT). No. of bitstreams: 1 Paula_MirianMichelleMachadode_M.pdf: 2407271 bytes, checksum: 8f5ae942d781fb23b3d817baa3c8a868 (MD5) Previous issue date: 2014 / Resumo: As promessas da utilização de nanotubos de carbono (CNTs) para fins biomédicos se esbarram em algumas dificuldades. Muitos estudos de nanotoxicologia foram realizados analisando propriedades destes materiais em causar injúrias no tecido vivo. Apesar das evidências da citotoxicidade dos CNTs, existe também um grande número de publicações de estudos de biomateriais baseados em CNTs que suportam sua biocompatibilidade. Segundo Lobo et al, 2009 (1), os nanotubos de carbono de parede múltipla (MWCNT) foram suficientes para obter biocompatibilidade. As estruturas de VAMWCNT alinhados revelaram que um ínfimo contato entre as estruturas das células e a nanotopografia é decisivo para garantir a bioatividade e eficiência no crescimento e espalhamento celular sem produzir efeitos citotóxicos. Resultados do nosso grupo mostrou características da adesão celular em substrato contendo VAMWCNT alinhado através da análise de proteínas envolvidas no mecanismo de adesão, assim como, estudo comparativo de preferência de substrato para proliferação e viabilidade celular onde verificou-se um melhoramento de adesão e espalhamento celular de acordo com o substrato de VAMWCNT utilizado, com ou sem tratamento de funcionalização a plasma de oxigênio. No entanto os substratos de VAMWCNT, apesar de atóxico, parecem provocar mudanças no comportamento celular principalmente no primeiro contato e durante o processo de adesão das células ao substrato. Neste estudo verificou-se que os substratos com VAMWCNT-O promoveram respostas pró-inflamatórias comparado ao controle. Os substratos com tratamento a plasma de oxigênio mostraram promover um maior estimulo celular dos macrófagos quanto a expressão de interleucina 6 além disso, verificou uma correlação entre os substratos hidrofílicos em maior produção de citocinas com o aumento de migração celular de células mononucleares da medula óssea in vivo. Mostrando, assim, que estes substratos podem acarretar uma melhora na estimulação do recrutamento celular e que podem favorecer o processo regenerativo de um tecido lesionado. Estes resultados demonstram um potencial do uso deste biomaterial na medicina regenerativa no futuro / Abstract: The promise of the use of carbon nanotubes (CNTs) for biomedical purposes faces some difficulties. Many studies of nanotechnology has been realized by analyzing the properties of these materials causing tissue injury in vivo. Despite evidence of cytotoxicity of CNTs, there are also a large number of published studies of biomaterials based on CNTs that support the idea of their biocompatibility. According to Lobo et al, 2009 (1), carbon nanotube multi-wall (MWCNT) showed biocompatibility. Vertically aligned VAMWCNT revealed that the contact between the structures of the cells and nanotopography is crucial to ensure bioactivity, cell growing and cell spreading, avoiding cytotoxic effects. Results from our group have showed cell adhesion on substrate containing VAMWCNT, as well as, variability of cell adhesion and spreading according to wet-ability features after oxygen plasma treatment (VAMWCNT-O) and density of the VAMWCNT substrate. However, VAMWCNT-O substrates, although nontoxic, seem to cause changes in cell behavior in the first contact and during the process of cell adhesion to the substrate. To better understand the behavior of cells on the substrates of VAMWCNT-O, in the present study, we analyzed the properties of macrophages to trigger inflammatory response in contact with substrates containing CNTs correlating it with mononuclear bone marrow cells migration. It was found that substrates with carbon nanotubes promoted pro-inflammatory responses compared to the control. The substrates after oxygen plasma treatment showed higher stimulation of macrophages as expression of interleukin 6 and SDF-1. They showed direct correlation with increasing bone marrow cell migration in vitro and in vivo. These substrates leaded to an improvement to cell recruitment and stimulation, which might support the process of regenerating an injured tissue by using them in regenerative medicine / Mestrado / Clinica Medica / Mestra em Clínica Médica

Page generated in 0.0903 seconds