• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 79
  • 9
  • 5
  • 5
  • 5
  • 5
  • 4
  • 1
  • 1
  • 1
  • Tagged with
  • 89
  • 52
  • 31
  • 25
  • 18
  • 17
  • 17
  • 14
  • 11
  • 11
  • 11
  • 11
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudio comparativo de filtración coronaria

Baden Silberstein, Nicole January 2006 (has links)
Trabajo de Investigación Requisito para optar al Título de Cirujano Dentista / El objetivo del presente estudio fue comparar la calidad de barrera a la microfiltración, in vitro, de tres materiales usados como selladores coronarios. Se seleccionaron 100 dientes humanos, con conducto único y recto, cuyas cavidades de acceso y conductos se prepararon de manera estandarizada. Todos los conductos se obturaron con gutapercha y Topseal dividieron aleatoriamente en 5 grupos de acuerdo al tipo de restauración coronal a recibir; 3 grupos de 30 dientes cada uno, uno con Óxido de Zinc Eugenol 5 mm. de espesor, otro con 2mm de adhesivo ScotchBond 2 + 3mm de vidrio ionómero y un tercer grupo con 2mm de OZE + 3mm de vidrio ionómero. En 10 dientes no se colocó ningún material de obturación coronal, 5 de ellos fueron completamente barnizados (control negativo), incluido su acceso coronario. Los 5 dientes restantes fueron barnizados exceptuando el acceso coronario (control positivo). Todas las muestras fueron articuladas en un tipodonto donde se les aplicaron 500 cargas verticales, para luego someterlas al termociclado durante 500 ciclos (5°- 55°C). Las muestras fueron completamente barnizadas, excepto 1mm alrededor del acceso coronario, para ser posteriormente inmersas en azul de metileno al 2%, durante 10 días, para determinar filtración. Las muestras fueron luego seccionadas y se registro en TM , y luego se 88 milímetros la penetración lineal del colorante. Los controles positivos exhibieron un 100% del conducto infiltrado, mientras que el control negativo no presentó filtración. Existió una diferencia estadísticamente significativa en cuanto a la micro filtración del colorante entre los tres materiales de restauración temporal (P = 0,043), pero no se encontró significancia estadística al comparar los grupos de manera individual entre sí. Todos los materiales se infiltraron en mayor o menor grado a los 10 días de inmersión en colorante.
12

Estudio in vitro de filtración apical obturando con Resilon y Topseal

Arroyo Armijo, Paula Alejandra January 2006 (has links)
Trabajo de Investigación Requisito para optar al Título de Cirujano Dentista / El propósito de este estudio fue evaluar in vitro la filtración apical en piezas dentarias humanas unirradiculares obturadas mediante condensación lateral usando gutapercha - Topseal y el sistema Resilon Epiphany, material de obturación a base de resina. Se utilizaron 64 dientes humanos uniradiculares que fueron aleatoriamente divididos en 2 grupos de 30 cada uno más 2 controles (+) y 2 controles (-). Los dientes fueron limpiados, trepanados, decoronados, conformados instrumentalmente y obturados, el grupo A con Resilon Epiphany y el grupo B con gutapercha y cemento Topseal. Fueron llevados a estufa de cultivo por 72 horas con 100% de humedad a 37° C hasta su fraguado total; posteriormente se sometieron a filtración pasiva, con azul de metileno al 2% durante 7 días, luego seccionadas longitudinalmente para medir la filtración radicular mediante microscopio estereoscópico (10x). Al aplicar el test de Student no pareado, no se encontró diferencias significativas entre los grupos experimentales, p< 0.05.
13

Influencia de irrigantes endodonticos na resistencia de união de um adesivo autocondicionante a dentina da camara pulpar

Santos, Juliana Nascimento 04 August 2005 (has links)
Orientador: Caio Cezar Randi Ferraz / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:48:38Z (GMT). No. of bitstreams: 1 Santos_JulianaNascimento_M.pdf: 2388300 bytes, checksum: a85a059075e841f9cf9e63475002101f (MD5) Previous issue date: 2005 / Resumo: A utilização de soluções irrigadoras e medicações durante o tratamento endodôntico pode ter um efeito deletério sobre a adesão às estruturas dentinárias da cavidade pulpar. Este estudo teve como objetivo avaliar in vitro a influência dos irrigantes endodônticos na resistência de união de um sistema adesivo autocondicionante à dentina da câmara pulpar de dentes bovinos. Setenta coroas de incisivos inferiores bovinos foram seccionadas expondo a câmara pulpar. O tecido pulpar foi removido e a embocadura do canal radicular selada com material restaurador provisório. Os espécimes foram divididos aleatoriamente em 7 grupos experimentais, de acordo com o irrigante utilizado: G1- NaCl 0,9%, G2- NaOCl 5,25%, G3- NaOCl 5,25% seguido por EDTA 17%, G4- sol. de gluconato de clorexidina 2%, G5- sol. de gluconato de clorexidina 2% seguida por EDTA 17%, G6- gluconato de clorexidina gel 2%, G7- gluconato de clorexidina gel 2% seguido por EDTA 17%. Cada solução permaneceu 30 min. em contato com as paredes da câmara pulpar com exceção do EDTA, que atuou por 5 min. Após o tratamento com os irrigantes, procedeu-se à lavagem com água destilada, secagem e aplicação do adesivo Clearfil SE Bond (Kuraray) seguido do compósito Filtek Z250 (3M), que foi inserido em incrementos. Após 24h de armazenamento em água a 37oC os espécimes foram submetidos ao teste de microtração, que verificou a resistência de união na interface resina-dentina. Os resultados obtidos em MPa (G1: 37,25 ± 2,07a; G2: 26,40 ± 2,07c; G3: 20,37 ± 1,46c; G4: 35,75 ± 1,85ab; G5: 34,79 ± 2,16ab; G6: 36,20 ± 1,53ab; G7: 33,09 ± 1,53b) foram analisados pelo teste de log-rank e observou-se diferença estatisticamente significativa (p<0,05) entre os grupos que utilizaram NaOCl (G2 e G3) e os demais. Além disso,o grupo que utilizou clorexidina gel 2% associada ao EDTA 17% (G7) apresentou diferença estatisticamente significativa em relação ao grupo do NaCl (G1). Concluiu-se então que, nas condições deste estudo, a resistência de união do sistema adesivo Clearfil SE Bond à dentina da câmara pulpar foi diminuída pela irrigação endodôntica com NaOCl 5,25% associado ou não ao EDTA / Abstract: Chemical irrigants and medications used in endodontic therapy may have an adverse effect on bonding to pulp chamber dentin. The aim of this study was to evaluate in vitro the influence of endodontic irrigants on the bond strength of a self etching adhesive system to bovine teeth pulp chamber dentin. Seventy crowns of bovine mandibular incisors were cut to expose the pulp chamber. The pulp was extirpated and the root canal orifice sealed with temporary restorative material. The specimens were divided into seven experimental groups, according to the solution used: G1- 0,9% NaCl, G2- 5,25% NaOCl, G3- 5,25% NaOCl and 17% EDTA, G4- 2% chlorhexidine gluconate solution, G5- 2% chlorhexidine gluconate solution and 17% EDTA, G6- 2% chlorhexidine gluconate in a gel base, G7- 2% chlorhexidine gluconate in a gel base and 17% EDTA. Each irrigant solution remained 30 minutes in contact with pulp chamber dentin, except for EDTA, which remained for 5 minutes. After irrigation, teeth were washed with distilled water and dried. A self etching adhesive system, Clearfil SE Bond (Kuraray), was applied according to manufacturer¿s instructions, followed by Filtek Z250 resin composite, which was applied in incremental layers. After 24h storage in 37°C distilled water, the microtensile bond test was performed. Bond strength values obtained in MPa (G1: 37,25 ± 2,07a; G2: 26,40 ± 2,07c; G3: 20,37 ± 1,46c; G4: 35,75 ± 1,85ab; G5: 34,79 ± 2,16ab; G6: 36,20 ± 1,53ab; G7: 33,09 ± 1,53b) were analyzed by the log-rank test (survival analysis) and statistical significant differences (p<0.05) were found between sodium hypochlorite groups (G2 and G3) and the other groups. Bond strength values of chlorhexidine gel and EDTA group (G7) were also statistically different from NaCl (control) group (G1). It could be concluded that, in the conditions of this experiment, bond strength of Clearfil SE Bond to pulp chamber dentin decreased when endodontic irrigation with 5,25% NaOCl associated or not to 17% EDTA was performed. / Mestrado / Endodontia / Mestre em Clínica Odontológica
14

Análise do efeito da aplicação direta de materiais capeadores à base de óleo de copaíba sobre a polpa de molares murinos / Analysis of the effect of the direct application of copaiba oil based capping materials on pulp murine teeth

Lima, Paula Loures Valle 19 March 2018 (has links)
Este estudo translacional avaliou o efeito da aplicação direta de materiais capeadores à base de óleo de copaíba sobre a polpa dentária de ratos. O biomaterial foi analisado de acordo com os processos inflamatórios, reparadores e regenerativos. Cavidades classe I foram preparadas na face oclusal dos molares superiores e inferiores de ratos da linhagem Wistar (n=120). Posteriormente, uma cavidade padronizada foi realizada com broca carbide esférica ¼. Exposições pulpares foram obtidas e após a hemostasia com algodão estéril e água destilada, foi realizado o capeamento pulpar com aplicação de biomateriais diretamente no tecido pulpar. Os biomateriais utilizados foram: COP (Óleo de Copaíba); Ca(OH)2 (hidróxido de cálcio), Ca(OH)2+COP; MTA (agregado trióxido mineral); MTA+COP; BIODENTINA (Biodentine®); BIODENTINA+COP. Todas as cavidades foram restauradas com cimento provisório. Os animais foram sacrificados após o período de 7, 14, 28 dias de acordo com os princípios de ética e experimentação animal. Vinte e um grupos foram criados a partir da combinação de tempos e materiais, cada grupo foi constituído de 5 animais. As peças foram preparadas e processadas pela técnica histológica e coradas pela HE (hemotoxilina e eosina) realizando cortes aleatórios, sendo analisados ao microscópio óptico em 100X de aumento por 2 examinadores. Os critérios avaliados foram: respostas inflamatória e degenerativa, organização tecidual, dentina reacional e reparativa. No último tempo experimental (28 dias) de todos os grupos foi analisado a superfície (mm2) e o volume (mm3) da ponte de dentina formada pela técnica da micro-CT (microtomografia computadorizada) de alta resolução. Os dados foram estatisticamente analisados utilizando o teste T pareado, determinando a superfície e volume da dentina reparadora formada entre os grupos experimentais. Nas análises histológicas foi utilizado o teste não-paramétrico de Mann-Whitney realizando comparações entre os grupos (?=5%). A BIODENTINA demonstrou uma tendência de acelerar o processo de regeneração pulpar, iniciando a deposição de dentina reparativa ao sétimo dia do capeamento. Este material apresentou uma dentina mais espessa em comparação com os outros biomateriais. O MTA também demonstrou uma eficiência na formação da ponte dentinária, entretanto em 20% das amostras não foi observada a presença de dentina reparadora. Ao acrescentar o COP nestes materiais, a formação da ponte dentinária apresentava heterogênea e incompleta, além disso esses grupos continham um processo inflamatório aumentado. A dentina reparadora do grupo de Ca(OH)2 demonstrou presença de túnel, com característica heterogênea. A adição do COP ao Ca(OH)2 aumentou a formação de dentina nas paredes ao redor da câmara pulpar em 80% das amostras, porém esta dentina não apresentava melhora na qualidade. Desta forma, o capeamento pulpar com COP isolado ou associado a Ca(OH)2, MTA e BIODENTINA não formou uma ponte de dentina completa e homogênea no local da exposição pulpar. / This translational study evaluated the effect of the direct application of copaiba oil based capping materials on the rat pulp. The biomaterial was analyzed according to inflammatory, repairing and regenerative processes. Class I cavities were prepared on the occlusal surface of the upper and lower molars of Wistar rats (n = 120). Subsequently, standardized cavities was performed with ¼ spherical carbide drill. Pulp exposures were obtained and after their hemostasis with sterile cotton and distilled water, pulp capping was done with application of biomaterials directly on the pulp tissue. The biomaterials used were: COP (Copaíba oil); Ca(OH)2 (calcium hydroxide), Ca(OH)2+COP; MTA (aggregate mineral trioxide); MTA+COP; BIODENTINE (Biodentine®); BIODENTINA+COP. All cavities were restored with temporary cement. The animals were sacrificed after the period of 7, 14, 28 days according to the principles of ethics and animal experimentation. Twenty-one groups were created from the combination of times and materials, each group consisted of 5 animals. The specimens were prepared and processed by histological technique and stained by HE (haemotoxin and eosin); randomized cuts were examined under optical microscope with 100X enlargement by two different examiners. The evaluated criteria were inflammatory and degenerative response, tissue organization, reactive and reparative dentin. In the last experimental period (28 days) of all groups, the surface (mm2) and the volume (mm3) of the reactive and reparative dentin formed were analyzed by the high-resolution micro-CT (computerized microtomography) technique. The data were statistically analyzed using the paired T-test, determining the surface and volume of the reparative dentin formed between the experimental groups. In the histological analyzes, the non-parametric Mann-Whitney test was used, comparing groups (? = 5%). BIODENTINE demonstrated a tendency to accelerate the process of pulpal regeneration, initiating the deposition of reparative dentin on the seventh day of the capping. This material had a thicker dentin compared to the other biomaterials. The MTA also demonstrated an efficiency in the formation of the dentin bridge; however, 20% of the samples did not observe the presence of reparative dentin. When adding the COP in these materials, the formation of the dentin bridge was heterogeneous and incomplete, in addition these groups contained an increased inflammatory process. The repair dentin of the Ca(OH)2 group showed a tunnel with a heterogeneous characteristic. The addition of COP to Ca(OH)2 increased dentin formation in the walls around the pulp chamber in 80% of the samples, but this dentin did not show improvement in quality. Thus, pulp cap with COP isolated or associated with Ca(OH)2, MTA and BIODENTINE did not form a complete and homogeneous dentin bridge at the site of pulp exposure.
15

Análise do efeito da aplicação direta de materiais capeadores à base de óleo de copaíba sobre a polpa de molares murinos / Analysis of the effect of the direct application of copaiba oil based capping materials on pulp murine teeth

Paula Loures Valle Lima 19 March 2018 (has links)
Este estudo translacional avaliou o efeito da aplicação direta de materiais capeadores à base de óleo de copaíba sobre a polpa dentária de ratos. O biomaterial foi analisado de acordo com os processos inflamatórios, reparadores e regenerativos. Cavidades classe I foram preparadas na face oclusal dos molares superiores e inferiores de ratos da linhagem Wistar (n=120). Posteriormente, uma cavidade padronizada foi realizada com broca carbide esférica ¼. Exposições pulpares foram obtidas e após a hemostasia com algodão estéril e água destilada, foi realizado o capeamento pulpar com aplicação de biomateriais diretamente no tecido pulpar. Os biomateriais utilizados foram: COP (Óleo de Copaíba); Ca(OH)2 (hidróxido de cálcio), Ca(OH)2+COP; MTA (agregado trióxido mineral); MTA+COP; BIODENTINA (Biodentine®); BIODENTINA+COP. Todas as cavidades foram restauradas com cimento provisório. Os animais foram sacrificados após o período de 7, 14, 28 dias de acordo com os princípios de ética e experimentação animal. Vinte e um grupos foram criados a partir da combinação de tempos e materiais, cada grupo foi constituído de 5 animais. As peças foram preparadas e processadas pela técnica histológica e coradas pela HE (hemotoxilina e eosina) realizando cortes aleatórios, sendo analisados ao microscópio óptico em 100X de aumento por 2 examinadores. Os critérios avaliados foram: respostas inflamatória e degenerativa, organização tecidual, dentina reacional e reparativa. No último tempo experimental (28 dias) de todos os grupos foi analisado a superfície (mm2) e o volume (mm3) da ponte de dentina formada pela técnica da micro-CT (microtomografia computadorizada) de alta resolução. Os dados foram estatisticamente analisados utilizando o teste T pareado, determinando a superfície e volume da dentina reparadora formada entre os grupos experimentais. Nas análises histológicas foi utilizado o teste não-paramétrico de Mann-Whitney realizando comparações entre os grupos (?=5%). A BIODENTINA demonstrou uma tendência de acelerar o processo de regeneração pulpar, iniciando a deposição de dentina reparativa ao sétimo dia do capeamento. Este material apresentou uma dentina mais espessa em comparação com os outros biomateriais. O MTA também demonstrou uma eficiência na formação da ponte dentinária, entretanto em 20% das amostras não foi observada a presença de dentina reparadora. Ao acrescentar o COP nestes materiais, a formação da ponte dentinária apresentava heterogênea e incompleta, além disso esses grupos continham um processo inflamatório aumentado. A dentina reparadora do grupo de Ca(OH)2 demonstrou presença de túnel, com característica heterogênea. A adição do COP ao Ca(OH)2 aumentou a formação de dentina nas paredes ao redor da câmara pulpar em 80% das amostras, porém esta dentina não apresentava melhora na qualidade. Desta forma, o capeamento pulpar com COP isolado ou associado a Ca(OH)2, MTA e BIODENTINA não formou uma ponte de dentina completa e homogênea no local da exposição pulpar. / This translational study evaluated the effect of the direct application of copaiba oil based capping materials on the rat pulp. The biomaterial was analyzed according to inflammatory, repairing and regenerative processes. Class I cavities were prepared on the occlusal surface of the upper and lower molars of Wistar rats (n = 120). Subsequently, standardized cavities was performed with ¼ spherical carbide drill. Pulp exposures were obtained and after their hemostasis with sterile cotton and distilled water, pulp capping was done with application of biomaterials directly on the pulp tissue. The biomaterials used were: COP (Copaíba oil); Ca(OH)2 (calcium hydroxide), Ca(OH)2+COP; MTA (aggregate mineral trioxide); MTA+COP; BIODENTINE (Biodentine®); BIODENTINA+COP. All cavities were restored with temporary cement. The animals were sacrificed after the period of 7, 14, 28 days according to the principles of ethics and animal experimentation. Twenty-one groups were created from the combination of times and materials, each group consisted of 5 animals. The specimens were prepared and processed by histological technique and stained by HE (haemotoxin and eosin); randomized cuts were examined under optical microscope with 100X enlargement by two different examiners. The evaluated criteria were inflammatory and degenerative response, tissue organization, reactive and reparative dentin. In the last experimental period (28 days) of all groups, the surface (mm2) and the volume (mm3) of the reactive and reparative dentin formed were analyzed by the high-resolution micro-CT (computerized microtomography) technique. The data were statistically analyzed using the paired T-test, determining the surface and volume of the reparative dentin formed between the experimental groups. In the histological analyzes, the non-parametric Mann-Whitney test was used, comparing groups (? = 5%). BIODENTINE demonstrated a tendency to accelerate the process of pulpal regeneration, initiating the deposition of reparative dentin on the seventh day of the capping. This material had a thicker dentin compared to the other biomaterials. The MTA also demonstrated an efficiency in the formation of the dentin bridge; however, 20% of the samples did not observe the presence of reparative dentin. When adding the COP in these materials, the formation of the dentin bridge was heterogeneous and incomplete, in addition these groups contained an increased inflammatory process. The repair dentin of the Ca(OH)2 group showed a tunnel with a heterogeneous characteristic. The addition of COP to Ca(OH)2 increased dentin formation in the walls around the pulp chamber in 80% of the samples, but this dentin did not show improvement in quality. Thus, pulp cap with COP isolated or associated with Ca(OH)2, MTA and BIODENTINE did not form a complete and homogeneous dentin bridge at the site of pulp exposure.
16

Estudio de la transportación del canal radicular a través de tomografía computarizada Cone Beam, utilizado tres sistemas de instrumentación rotatoria

Salazar Linfati, Daniela Fernanda January 2012 (has links)
Trabajo de Investigación Requisito para optar al Título de Cirujano Dentista / En la preparación del sistema de conductos radiculares se debe lograr una conformación progresivamente cónica desde apical hacia coronal, sin generar accidentes de procedimiento. Se define como transportación al cambio de ubicación espacial del canal radicular con respecto a su ubicación original, produciéndose así un desgaste no proporcional de alguna de las paredes dentinaria en relación con la anatomía original de este. Durante la última década, se han fabricado nuevos instrumentos endodónticos rotatorios en base a Níquel-Titanio (NiTi), lo que provee una mayor flexibilidad y resistencia a la fractura, disminuye el tiempo de trabajo y la fatiga del operador, facilitando así la conformación adecuada del canal y reduciendo accidentes durante los procedimientos. El propósito de este estudio fue comparar experimentalmente el grado de transportación del tercio medio y apical del canal radicular, utilizando tres sistemas de instrumentación rotatoria: ProTaper Universal, RaCe y K3. Se realizó un estudio in vitro, de 45 canales radiculares humanos superiores e inferiores con curvaturas moderadas a severas, seleccionados a través de radiografías periapicales. Se formaron 3 grupos de 15 conductos que fueron preparados con los sistemas de instrumentación rotatoria antes mencionados. Se utilizó tecnología Cone Beam para registro de imágenes previas y posteriores a la instrumentación, las que se tomaron a través de rodetes de silicona conformando una arcada dentaria con la idea de ser un montaje reproducible postinstrumentación. Se realizaron mediciones en los cortes tomados a los 2, 4, 6, y 8 mm desde el ápice por canal instrumentado, en cada corte se realizaron 4 mediciones, pared vestibular, lingual, furca y cara libre. Los datos obtenidos fueron analizados mediante test Wilcoxon para muestras pareadas y el test ANOVA. 2 Los resultados indican que el sistema ProTaper Universal produce mayor transportación del canal radicular a nivel del tercio medio en comparación con los sistemas RaCe y K3. Además el sistema K3 mostró un desgaste más conservador a los 2, 4 y 6 mm de instrumentación de los canales radiculares haciéndolo recomendable para instrumentación de canales finos y curvos.
17

Variação da temperatura no interior da câmara pulpar em função de diferentes fontes de luz e camadas de resina composta. In vitro / In vitro temperature variation inside the pulp chamber regard different light sources and composite layers

Andreatta, Ligia Maria Lima 31 March 2015 (has links)
Este estudo in vitro avaliou a variação da temperatura no interior da câmara pulpar durante a fotoativação do sistema adesivo e incrementos de resina composta em função de diferentes fontes de luz, testando as hipóteses nulas de que estes fatores não interferem na temperatura intra câmara pulpar. Foram selecionados 10 incisivos bovinos, seccionados na região radicular 3 mm além da junção amelocementária. Uma cavidade retangular (10X8mm) foi confeccionada no centro da face vestibular, com espessura padronizada do remanescente dentinário da parede axial em 1 mm. A câmara pulpar foi preenchida com pasta térmica e o sensor termopar tipo K foi introduzido na câmara em contato com o remanescente dentinário. A elevação da temperatura foi aferida durante 40s de fotoativação do sistema adesivo (SBMP) e dos 3 incrementos consecutivos de 1mm de resina composta (Z250), com diferentes fontes de luz. As fontes utilizadas foram: Luz Halógena 755mW/cm2 (Curing Light XL 3000 3M), Luz emitida de diodo (LED) de baixa densidade de potência 400 mW/cm2 (OptiLight LD Max - Gnatus), e LED de alta densidade de potência 1500mW/cm2 (VALO Ultradent). O LED de alta densidade de potência proporcionou os maiores aumentos de temperatura, seguido da luz halógena e do LED de baixa densidade de energia. A polimerização do sistema adesivo seguido do primeiro incremento de resina determinou os maiores aumentos de temperatura. A partir do segundo incremento da resina composta, o material restaurador atuou como isolante térmico reduzindo o aumento de temperatura. Independente da fonte de luz e etapa restauradora, o aumento no tempo de polimerização foi determinante no aumento de temperatura, rejeitando as hipóteses nulas testadas. / This In vitro study evaluated the temperature variation inside the pulp chamber during the curing of the adhesive and composite layers with different light sources, testing the null hypothesis that these factors do not affect the temperature of the intra pulp chamber. Ten bovine incisors were selected and sectioned beyond the root region at 3 mm of the cementoenamel junction. A rectangular cavity (10x8mm) was made in the center of the buccal surface, with the remaining 1mm dentin thickness standardized at the axial wall. The pulp chamber was filled with thermal paste and a type K thermocouple sensor was introduced into the chamber in contact with the remaining dentin. The temperature was measured for 40s during the curing of the adhesive system (SBMP) and 3 consecutive layers of 1mm composite resin (Z250) was applied with three different light sources. The sources used were: Halogen Light 755mW/cm2 (Curing Light XL 3000 - 3M), Light emitted diode (LED) low power density 400 mW/cm2 (Optilight LD Max - Gnatus), and high power density LED 1500mW/cm2 (VALO Ultradent). For all light sources, the temperature readings decreased as the cavity was filled, with statistically significant differences until the second layer of composite resin. The high power density LED showed a significantly higher temperature average (42.78+1.56oC) than the other light sources, and the lowest was the average of the low power density LED (37.81+0.12oC). It could be concluded that both the light source, and the number of layers interfered with the temperature variation, rejecting the null hypotheses tested.
18

Avaliação da dentina de dentes decíduos submetidos à técnica de remoção parcial de tecido cariado

Dalpian, Débora Martini January 2009 (has links)
O objetivo deste estudo foi avaliar a microdureza Knoop da dentina cariada remanescente de dentes decíduos submetidos ao capeamento pulpar indireto (CPI) e restaurados com sistema adesivo autocondicionante e resina composta, associado ou não a uma base forradora de cimento de hidróxido de cálcio. Para tal, molares decíduos submetidos ao CPI e restaurados com Clearfil SE Bond – Kuraray, Japão (CSE) e resina composta Filtek Z250 – 3M Espe, EUA foram acompanhados clínica e radiograficamente até a esfoliação. Foram coletados 7 dentes do grupo onde foi aplicado o Dycal – Dentsply, EUA (DY) e 10 com CSE sobre o remanescente cariado e comparados com 10 molares decíduos hígidos com preparo cavitário in vitro de 3 a 4 mm de profundidade, e 10 molares decíduos cariados, submetidos a RPTC in vitro. As mensurações de microdureza foram realizadas, após secção e polimento, a partir da porção mais profunda da cavidade em direção à câmara pulpar nas profundidades de 10, 35, 60, 85, 110, 200μm e, a partir desta, pontos equidistantes 100μm até atingir o teto da câmara pulpar. Entre os grupos CSE e DY não houve diferença nos valores de microdureza em todas as profundidades, porém quando comparados aos Cariados, o CSE apresentou valores significativamente maiores a partir da profundidade 35μm, enquanto esse aumento só foi detectado em 200μm no DY. A partir de 700μm não ocorreu diferença nos valores de microdureza entre todos os grupos. Com base nos resultados, conclui-se que os dentes decíduos submetidos ao CPI apresentaram aumento da microdureza, independentemente do uso de base forradora de Dycal ou CSE. / The aim of this study was to evaluate remaining carious dentin microhardness from deciduous teeth submitted to Indirect Pulp Treatment (IPT) and restored with self etching primer and composite, associated or not with calcium hydroxide capping. Deciduous molars treated with IPT and restored with Clearfil SE Bond – Kuraray, Japan (CSE) and composite Filtek-Z250 – 3M ESPE, EUA were clinically and radiographically evaluated until exfoliation. Seven teeth capped with calcium hydroxide (Dycal – Dentsply, EUA – DY) and 10 with CSE were collected and compared with 10 sound deciduous molars where 3- to 4-mm deep cavities were prepared, and also with 10 carious molars were partial caries removal was conducted in vitro. Microhardness analysis was performed after sample sectioning and polishing, at 10-, 35-, 60-, 85-, 110- and 200-μm depths and later each 100μm until reaching the pulpar chamber roof. No difference was observed in microhardness values between CSE and DY groups in all depths analyzed, otherwise when compared with carious group, CSE presented significantly higher values from 35μm depth, while this increase was observed only with 200μm in the DY group. From 700μm depth no difference was observed in the microhardness values between all groups in study. It can be concluded that deciduous teeth submitted to IPT presented a hardness increase, independently of the capping material type, Dycal or CSE.
19

Efeitos do tipo de sistema adesivo e região do dente sobre a resistência adesiva à dentina /

Melo, Renata Marques de. January 2005 (has links)
Orientador: Carlos Augusto Pavanelli / Banca: Paulo Sérgio Mutarelli / Banca: Carlos Rocha Gomes Torres / Resumo: Este estudo foi realizado no intuito de avaliar a resistência de união à dentina coronária e do canal radicular com dois sistemas adesivos de condicionamento total (dois e três passos) e um sistema autocondicionante. Os canais de trinta incisivos e caninos humanos superiores foram instrumentados e preparados com brocas. Os pinos usados na cimentação foram réplicas em cimento resinoso dual Duo-link do pino Aestheti Plus #2. Assim, constituíram-se três grupos (n = 10), segundo o sistema adesivo utilizado: condicionamento total três passos (CT3) - AII-Bond 2 + pino em cimento resinoso (pcr)+ Duo-link (DI); condicionamento total 2 passos (CT2) - One-Step Plus + pcr + DI; autocondicionante (AC) - Tyrian/One-Step Plus+ pcr + DI. Apôs a cimentação, foram obtidas oito secções transversais (1,5mm), a partir de 4mm acima da JEC até 4mm aquém do ápice do canal, envolvendo dentina coronária e radicular. As secções foram submetidas ao ensaio de push-out em máquina de ensaio universal EMIC (1 mm.min-1). Os dados de resistêncía adesiva foram analisados com o teste ANOVA de dois fatores de medidas repetidas (α<0,05). Foi observado que o efeito interação foi estatisticamente significante, isto é, o relacionamento entre os adesivos não foi o mesmo para as diferentes regiões. Comparando-se as médias obtidas com os adesivos em cada região (Tukey; α<0,05), observou-se que o CT3 (média± desvio padrão: 5,22 ± 1,70) foi superior ao CT2 (2,60 ± 1,74) e ao AC (1,68 ± 1,85). Para as condições estudadas, obteve-se melhor adesão à dentina com a utilização do sistema adesivo de condicionamento total com três passos, sobretudo na região coronária / Abstract: This study aimed to evaluate lhe bond strengths between two total etching adhesive systems and (two and three steps) anda self-etching system to coronal and root canal dentin. The root canal of thirty human anterior teeth were endodontically instrumented and prepared with specific burs. Aestheti Plus #2 posts were duplicated in dual resin cement (Duo-link) and three groups (n=10) were formed, according to the adhesive sysfem used: 3 steps total etching adhesive system (3TE) - All-Bond 2 + resin cement post (rcp) + Duo-link (DI); 2 steps total etching adhesive system (2TE) - One-Step Plus + rcp + DI; sef-etching system (SE) Tyrian/One-Step Plus + rcp +DI. Following cementation, the teeth were cut transversally in eight sections (1,5mm), from the CEJ to 4mm above the canal apex. The sections were subjected to the push-out test in a universal testing machine (1mm.min-1). The data of bond strength were statistically analyzed with 2-way Anova of repeated measures (α<0.05), which showed that the interaction effect was significant. This meant that the relationship between the adhesives was not the same depending on the tooth region. Regarding the "adhesive factor'' the comparison of means with Tukey test (α<0.05) showed that 3TE (mean ± standard deviation: 5,22 ± 1,70) was statistically superior to 2TE (2,60 ± 1,74) and SE (1,68 ± 1,85). Under the conditions of the present study, the three step total etching system had the highest bond strengths to dentin, especially in the coronal region / Mestre
20

Avaliação da biocompatibilidade de dois adesivos dentinários pelo estudo das reações teciduais em conjuntivo de ratos /

Gomes, Ana Paula Martins. January 1994 (has links)
Orientador: Jaime Freitas Ribeiro / Banca: Carlos Eduardo Aun / Banca: Maria Amélia Maxímo de Araújo / Resumo: A biocompatibilidade de dois adesivos dentinários (Scotchbond MultiPurpose- 3M e Optibond Multi-Use - Kerr) foi avaliada por meio de implantes em tecido conjuntivo subcutâneo de ratos. Os implantes foram realizados, utilizando-se tubos de polietileno preenchidos com os respectivos adesivos e inseridos em lojas cirúrgicas preparadas no dorso dos animais, os quais foram sacrificados nos periodos de observação de 14, 30, 60 e 84 dias. Os tecidos circunjacentes aos implantes foram removidos, incluídos em parafina e corados com hematoxilina e eosina para análise em microscopia óptica. Os resultados mostraram moderado a discreto infiltrado inflamatório nos períodos iniciais de observação (14 e 30 dias) e reparação da área nos períodos posteriores (60 e 84 dias), com formação de cápsula fibrosa envolvendo todos os implantes. Os resultados obtidos nos permitiram concluir que: a) os dois adesivos dentinários são biologicamente aceitáveis quando colocados em contato com o tecido conjuntivo subcutâneo de ratos; b) houve reação moderada do tecido conjuntivo subcutâneo de ratos aos dois adesivos dentinários no período de observação de 14 dias, a qual persistiu com o adesivo Optibond MultiUse-light cure- (Kerr) aos 30 dias; c) as reações teciduais provocadas pelos dois adesivos nos períodos de observação de 60 e 84 dias foram semelhantes e biologicamente aceitáveis / Abstract: The biocompatibility of two dentin adhesives (Scotchbond MultiPurpose- 3M and Optibond Multi-Use - Kerr) was evaluated in rats subcutaneous connective tissue implants. Polyethylene tubes filled with the adhesives were surgically implanted into the dorsal subcutaneous tissues of rats. The tubes were left implanted for periods of 14, 30, 60 and 84 days, following wich the animais were killed and the implants, together with the surrounding tissue, were excised. The specimens were then fixed in 10 per cent formalin, sectioned serially and stained with hematoxylin and eosin and then, examined by light microscopy. After 14 and 30 days the tubes were surrounded by a mild to moderate inflammatory infiltration. After 60 and 84 days microscopic examination revealed the formation of a connective tissue capsule around each tube. The microscopic examination of the biopsy specimens allowed to conclude that: a) both dentin adhesives are considered biologically acceptable when placed in contact with rats subcutaneous connective tissue; b) in the observation period of 30 days there were moderate tissue reaction to the Optibond Multi-Use -light cure- (Kerr); c) after 60 and 84 days the use of both dentine adhesives did not interfere in the healing of the surrounding connective tissue / Mestre

Page generated in 0.0442 seconds