Dosimetria em tomografia computadorizada de feixe cônico na odontologiaANDRADE, Marcos Ely Almeida 31 January 2013 (has links)
Submitted by Amanda Silva (amanda.osilva2@ufpe.br) on 2015-03-04T12:45:07Z
No. of bitstreams: 2
Tese Marcos Ely Almeida.pdf: 16844253 bytes, checksum: f826a3ada42c1b6941cd1f33a58b96fe (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-04T12:45:07Z (GMT). No. of bitstreams: 2
Tese Marcos Ely Almeida.pdf: 16844253 bytes, checksum: f826a3ada42c1b6941cd1f33a58b96fe (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Previous issue date: 2013 / CNPq / A tomografia computadorizada tem sido bastante utilizada na Odontologia, com aplicações
em diversas especialidades, destacando-se o planejamento de implantes dentários. Avanços
tecnológicos permitiram o desenvolvimento da tomografia computadorizada de feixe cônico
(CBCT), que produz imagens com resolução mais elevada que os tomógrafos helicoidais. Este
trabalho teve como objetivo realizar um estudo dosimétrico e de qualidade das imagens de
equipamentos de CBCT utilizados na Odontologia, mais especificamente no planejamento de
implantes dentários. O estudo foi realizado com três tomógrafos de feixe cônico: i-CAT
classic; PreXion 3D; e Kodak 9000, utilizando diferentes protocolos de aquisição e tamanhos
de campos de radiação (FOVs). Foram estimados os valores de produto kerma ar-área (PKA) e
kerma ar na superfície utilizando um phantom antropomórfico, modelo RS-250, um medidor
de PKA e dosímetros termoluminescentes (TLDs) posicionados na região dos olhos, glândulas
parótidas, submandibulares e tireoide. Também foram realizadas medições das doses
absorvidas nos órgãos, com dosímetros TL inseridos em um phantom Alderson RANDO, na
posição de vários órgãos, tais como olhos, tireoide, medula óssea e cérebro. A qualidade das
imagens foi avaliada utilizando simuladores de controle de qualidade, fornecidos com o
tomógrafo i-CAT classic, e analisando os parâmetros físicos, medidos nas imagens do
phantom RS-250: razão sinal-ruído (SNR); razão contraste ruído (CNR); e contraste (C). Os
resultados mostraram que os valores de PKA obtidos com o i-CAT classic variaram de 24 a
180 μGy.m2 e com o PreXion 3D, a variação foi de 70 a 138 μGy.m2, dependendo do
protocolo de irradiação. A comparação do PKA obtido com estes tomógrafos, utilizando FOV
de tamanho semelhante e o mesmo protocolo de aquisição, mostrou que os valores obtidos
com o i-CAT classic foram menores que os valores obtidos com o PreXion 3D. No caso do
Kodak 9000, foi utilizado apenas um protocolo e o PKA obtido foi de 69 μGy.m2, que é menor
que o PKA com o i-CAT para o mesmo tamanho de campo. Os valores de kerma ar na
superfície na região dos olhos variaram de 0,08 a 3,39 mGy; nas parótidas, de 0,50 a
4,14 mGy; nas submandibulares, de 0,09 a 2,95 mGy; e na tireoide, de 0,05 a 1,32 mGy.
Observou-se, para o tomógrafo i-CAT classic, que uma redução no tamanho de campo pode
resultar em redução de até 90% no kerma ar na região dos olhos. Os valores de doses
absorvidas nos órgãos foram, em grande parte, mais elevados para os exames efetuados com o
tomógrafo PreXion 3D. Porém, como o PreXion 3D utiliza um tamanho de campo menor,
alguns órgãos apresentaram doses menores em relação ao i-CAT classic, como tireoide e
esôfago. É possível concluir que os resultados de doses absorvidas obtidos foram similares a
outros trabalhos publicados e muito inferiores às doses obtidas com exames em tomógrafos
helicoidais. Os protocolos de alta-resolução resultaram em doses absorvidas mais elevadas,
porém, com relação às imagens avaliadas, apresentaram melhor resolução espacial, mas sem
variação dos valores de SNR ou CNR. Portanto, nos exames em que não há necessidade de
visualizar detalhes, os protocolos padrões são recomendados, por resultarem em metade da
dose absorvida no paciente.
|
32 |
Comparação entre a imagem radiografica interproximal convencional e a digital direta na detecção de cáries proximais /Araujo, Elaine Aparecida Félix de. January 2001 (has links)
Orientador: Julio Cezar de Melo Castilho / Banca: Claudio de Freitas / Banca: Luiz Cesarr de Moraes / Resumo: O objetivo neste trabalho foi o de avaliar a acurâcia na detecção de cáries proximais comparando a imagem digital e a imagem digital modificada brilho e contraste com os filmes Ektaspeed Plus e INSIGHT. Foram radiografados 52 pré-molares humanos extraídos e submetidos à idêntica padronização geométrica e condições de exposição. Usando uma escala de confiança com seis escores, quatro observadores, determinaram a ausência ou presença de cárie por quatro modalidades de imagem: a) filme Ektaspeed Plus; b) filme INSIGHT; c) digital direta; d) digital com modificação de brilho e contraste. O padrão real foi determinado pela análise microscópica das secções. Com os valores obtidos foi gerada uma curva ROC, avaliando a sensibilidade e especificidade dos métodos e com o teste estatístico Kappa de Cohen foi obtida a concordância inter observadores. Os resultados mostraram diferenças insignificantes entre a imagem digital e a radiográfica convencional (P>005) / Abstract: The purpose this study was to evaluate the accuracy of proximal caries detectíon comparing enhanced and unenhanced Sidexis CCD-based digital image with Ektaspeed Plus and lnsight films. Fifty-two extracted teeth posterior were imaged under identical standardized geometric and exposure condítions. Four observes, using six point confidence scale, rated 104 proximal surfaces for the presence or absence of carious lesions by means of four image modalities: a) Ektaspeed Plus films; b) INSIGHT films; c) unenhanced Sidexis displays; d) obsever enhanced. The real pattern was determined by microscopy analysis of sections. Receiver Operating Characteristic curves were generated analyzed with Kappa the according interobservers. The results indicated that there wasn't significant difference between unenhanced Sidexis and film images (P >0,05) / Mestre
|
33 |
Comparação entre imagens digitais diretas e laser de diodo na detecção de cáries proximais e oclusais /Araujo, Elaine Aparecida Félix de. January 2004 (has links)
Orientador: Julio Cezar de Melo Castilho / Banca: Solange Maria de Almeida / Banca: Claudio Costa / Banca: Mari Elí Leonelli de Moraes / Banca: Ana Paula Martins Gomes / Resumo: O objetivo neste trabalho foi avaliar a acurácia na detecção de cáries proximais e oclusais comparando a imagem digital com o laser de diodo. Foram avaliados 33 pré-molares e 33 molares humanos extraídos e submetidos à idêntica padronização geométrica. Usando uma escala de confiança com cinco escores, quatro observadores determinaram a ausência ou presença de cárie por três sistemas auxiliares de diagnóstico: a) exame da imagem do Visualix; b) exame da imagem do RVG; c) exame utilizando o DIAGNOdent. O padrão ouro foi determinado pela análise histológica das secções. Com os valores obtidos foi gerada uma curva ROC e realizado o teste Kappa que determinou a concordância intra e ínterobservadores. Os resultados indicaram que as imagens digitais foram melhores na detecção de cáries proxímais que o laser DIAGNOdent e semelhantes na detecção de cáries oclusais / Abstract : The purpose of this study was to evaluate the accuracy of approximal and occlusal caries detection comparing Visualix and RVG CCD-based digital image with laser DIAGNOdent Sixty-six extracted posterior teeth were imaged under identical standardized geometric and exposure conditions. Four examiners, using five point confidence scale, rated 132 proximal and 66 occlusal surfaces for the presence or absence of carious lesions by means of three diagnostic systems: a) Visualix; b) RVG; c) DIAGNOdent. The gold standard was determined by microscopy analysis of sections. Receiver Operating Characteristic curves were generated analyzed with Kappa the according intra and interexaminers. The results indicated that digital images were better to detection approximal caries than laser Diagnodent and similar to occlusal caries / Doutor
|
34 |
Estudo experimental da otimização em sistemas de mamografia digital CR e DR / Experimental study of optimization in CR and DR digital mammography systemsPerez, Alessandra Maia Marques Martinez 29 January 2015 (has links)
A recente inserção e forte avanço da mamografia digital no Brasil como ferramenta de rastreamento do câncer mamário e as evidências de outras condições de otimização, quando comparadas à mamografia convencional (tela filme), requerem que novos parâmetros de qualidade sejam incluídos e estudados, bem como que as condições de otimização sejam revistas. O objetivo deste trabalho foi determinar a técnica radiográfica otimizada para dois sistemas de detecção (CR e DR) em uso em três unidades de mamografia: Mammomat 3000 Nova (Siemens), Senographe DMR (GE) e Senographe 2000D (GE). A otimização foi conduzida para uma variedade de combinações de fatores técnicos e configurações de simuladores de mama, tais como valores de kilovoltagem (26 a 32 kV), combinações anodo/filtro (Mo/Mo, Mo/Rh e Rh/Rh), material simulador de mama de várias espessuras (2 a 8 cm) e lesões simuladas como massas e calcificações, usando uma figura de mérito (FOM) como parâmetro. Verificou-se que o uso da combinação anodo/filtro que gera os espectros mais energéticos em cada equipamento proporcionou os maiores valores de FOM para todas as espessuras de simulador de mama e voltagens, devido a redução da dose. As combinações anodo/filtro que deram esses resultados foram Mo/Rh para o equipamento da marca Siemens e Rh/Rh para ambos os equipamentos da marca GE, correspondentes aos espectros mais energéticos de cada unidade. Foi observada ainda uma tendência de aumento do kV que maximiza FOM com o aumento da espessura. / The recent introduction and intense advance of digital mammography in Brazil as a tool in breast cancer screening and the evidences of new optimization conditions when compared to conventional mammography (screen-film) require adding and studying novel quality parameters, as well as revisiting optimization conditions. The objective of this work was to determine optimized radiographic technique for two detection systems (CR and DR) in use in three mammography units: Mammomat 3000 Nova (Siemens), Senographe DMR (GE) and Senographe 2000D (GE). Optimization was conducted for various combinations of technique factors and breast phantom configurations, such as kilovoltage settings (26 to 32 kV), target/filter combinations (Mo/Mo, Mo/Rh and Rh/Rh), breast equivalent material in various thicknesses (2 to 8 cm) and simulated mass and calcification lesions, using a figure of merit (FOM) as a parameter. When using anode/filter combination which generates higher energy spectra in each equipment, it was verified that higher FOM values were achieved for all voltages and phantom thicknesses, due to dose reduction. Anode/filter combinations which led to those results were Mo/Rh for Siemens equipment and Rh/Rh for both GE equipments, corresponding to the higher energy spectra in each unity. It was also observed an increasing tendency of kV which maximizes FOM with the increase of thickness.
|
35 |
Reconstrução espectral de tubos de radiação odontológicos usando a transformada inversa de Laplace da curva de atenuação / Spectral Reconstruction of Dental X Ray Tubes Using the Inverse Laplace Transform of the Attenuation Curve.Malezan, Alex 27 June 2013 (has links)
No estudo de imagens radiográcas, os parâmetros relacionados ao contraste objeto, SC, razão sinal ruído, SNR, e dose, estão vinculados à forma do espectro de raios X utilizado e seu conhecimento permite predizer e otimizar a qualidade da imagem. Neste trabalho foi desenvolvida uma metodologia que permite obter o espectro de tubos de raios X odontológicos de uso clínico de forma indireta. Esta metodologia é baseada na aplicação de um modelo matemático que utiliza a transformada inversa de Laplace da curva de transmissão do feixe para gerar dados sobre a distribuição espectral do mesmo. Com o auxílio de uma câmara de ionização e ltros alumínio de alta pureza, foram levantadas as curvas de transmissão de 8 tubos de raios X disponíveis comercialmente. Para a validação do método foi realizada a espectrometria direta com detector de telureto de cádmio (CdTe), cuja resposta foi determinada por simulação Monte Carlo (MC). A partir reconstrução espectral obtida, foram realizados estudos sobre os parâmetros de qualidade de imagem SNR, contraste objeto, SC, KERMA na entrada da pele. O desempenho dos tubos foi avaliado com base na relação entre SNR e KERMA na entrada da pele. Os resultados mostram que é possível determinar a distribuição espectral de tubos de raios X odontológicos com base no método proposto. A relação proposta entre SNR e KERMA na entrada da pele sugere que tubos com fótons de baixa energia possuem baixo rendimento. / In the study of radiographic images, the parameters related to the subject contrast, SC, signal to noise ratio, SNR, and dose, are linked to the shape of the X-ray spectrum used and their knowledge allows to predict and optimize the image quality. In this work we developed a methodology to obtain the spectrum of dental X-ray tubes of clinical usage in an indirety way. This methodology is based on application of a mathematical model that uses the inverse Laplace transform of the attenuation curve to generate data on the spectral distribution of the beam. With the aid of an ionization chamber and high purity aluminum lters, were raised the transmission curves of 8 X-ray tubes that are available commercially. The method validation was performed with direct spectrometry detector cadmium telluride (CdTe), whose response was determined by Monte Carlo simulation (MC). From reconstruction obtained spectral studies were carried out on the parameters of SNR image quality, contrast object, SC, KERMA entrance skin. The performance of the tubes was evaluated based on the relationship between SNR and KERMA entrance skin. The results show that it is possible to determine the spectral distribution of dental X-ray tubes based on the proposed method. The proposed relationship between SNR and KERMA entrance skin suggests that tubes with low energy photons have a low performance.
|
36 |
[en] IMAGE QUALITY METRICS FOR FACE RECOGNITION / [pt] MEDIDAS DE QUALIDADE DE IMAGENS PARA RECONHECIMENTO FACIALJOSÉ LUIZ BUONOMO DE PINHO 09 April 2014 (has links)
[pt] O Reconhecimento Facial é o processo de identificação de uma pessoa a
partir da imagem de sua face. Na forma mais usual, o processo de identificação
consiste em extrair informações dessa imagem e compará-las com informações
relativas a outras imagens armazenadas numa base de dados e por fim indicar na
saída a imagem da base mais similar à imagem de entrada. O desempenho desse
processo está diretamente ligado à qualidade das imagens, tanto das que estão
armazenadas na base de dados, quanto da imagem do indivíduo cuja identidade
está sendo determinada. Por isso, convém que a qualidade das imagens faciais seja
avaliada antes que estas sejam submetidas ao procedimento de reconhecimento.
A maioria dos métodos apresentados até o momento na literatura baseia-se em um
conjunto de critérios, cada um voltado a um atributo isolado da imagem. A
qualidade da imagem é considerada adequada se aprovada por todos os critérios
individualmente. Desconsidera-se, portanto, o efeito cumulativo de diversos
fatores que afetam a qualidade das imagens e, por conseguinte, o desempenho do
reconhecimento facial. Essa monografia propõe uma metodologia para o projeto
de métricas de qualidade de imagens faciais que expressem num único índice o
efeito combinado de diversos fatores que afetam o reconhecimento. Tal índice é
dado por uma função de um conjunto de atributos extraídos diretamente da
imagem. O presente estudo analisa experimentalmente uma função linear e uma
rede neural do tipo back-propagation como alternativas para a estimativa de
qualidade a partir dos atributos. Experimentos conduzidos sobre a base de dados
IMM para o algoritmo de reconhecimento baseado em padrões binários locais
comprovam a o bom desempenho da metodologia. / [en] Face Recognition is the process of identifying people based on facial
images. In its most usual form the identification procedure consists of extracting
information from an input face image and comparing them to the records of other
face images stored in a face data base, and finally indicating the most similar one
to the input image. The performance of this process is directly dependent on the
input image quality, as well as on the images in the data base. Thus, it is important
that the quality of a face image is tested before it is given to the recognition
procedure, either as a input image or as a new record in the face database. Most
methods proposed thus far based on a set of criteria, each one devoted to an
isolated attribute. The image quality is considered adequate if approved by all
criteria individually. Thus, the cumulative effect of different factors affecting the
image quality is no regarded. This dissertation proposes a methodology for the
design of quality metrics of facial images that Express in a single scalar the
combined effect of multiple factors affecting the quality. Such score is given by a
function of attributes extracted directly from the image. This study investigates a
linear and a non-linear approach for quality assessment. Experiments conducted
upon the IMM face database for a Local Binary Pattern face recognition
algorithm demonstrate the good performance of the proposed methodology.
|
37 |
Reconstrução espectral de tubos de radiação odontológicos usando a transformada inversa de Laplace da curva de atenuação / Spectral Reconstruction of Dental X Ray Tubes Using the Inverse Laplace Transform of the Attenuation Curve.Alex Malezan 27 June 2013 (has links)
No estudo de imagens radiográcas, os parâmetros relacionados ao contraste objeto, SC, razão sinal ruído, SNR, e dose, estão vinculados à forma do espectro de raios X utilizado e seu conhecimento permite predizer e otimizar a qualidade da imagem. Neste trabalho foi desenvolvida uma metodologia que permite obter o espectro de tubos de raios X odontológicos de uso clínico de forma indireta. Esta metodologia é baseada na aplicação de um modelo matemático que utiliza a transformada inversa de Laplace da curva de transmissão do feixe para gerar dados sobre a distribuição espectral do mesmo. Com o auxílio de uma câmara de ionização e ltros alumínio de alta pureza, foram levantadas as curvas de transmissão de 8 tubos de raios X disponíveis comercialmente. Para a validação do método foi realizada a espectrometria direta com detector de telureto de cádmio (CdTe), cuja resposta foi determinada por simulação Monte Carlo (MC). A partir reconstrução espectral obtida, foram realizados estudos sobre os parâmetros de qualidade de imagem SNR, contraste objeto, SC, KERMA na entrada da pele. O desempenho dos tubos foi avaliado com base na relação entre SNR e KERMA na entrada da pele. Os resultados mostram que é possível determinar a distribuição espectral de tubos de raios X odontológicos com base no método proposto. A relação proposta entre SNR e KERMA na entrada da pele sugere que tubos com fótons de baixa energia possuem baixo rendimento. / In the study of radiographic images, the parameters related to the subject contrast, SC, signal to noise ratio, SNR, and dose, are linked to the shape of the X-ray spectrum used and their knowledge allows to predict and optimize the image quality. In this work we developed a methodology to obtain the spectrum of dental X-ray tubes of clinical usage in an indirety way. This methodology is based on application of a mathematical model that uses the inverse Laplace transform of the attenuation curve to generate data on the spectral distribution of the beam. With the aid of an ionization chamber and high purity aluminum lters, were raised the transmission curves of 8 X-ray tubes that are available commercially. The method validation was performed with direct spectrometry detector cadmium telluride (CdTe), whose response was determined by Monte Carlo simulation (MC). From reconstruction obtained spectral studies were carried out on the parameters of SNR image quality, contrast object, SC, KERMA entrance skin. The performance of the tubes was evaluated based on the relationship between SNR and KERMA entrance skin. The results show that it is possible to determine the spectral distribution of dental X-ray tubes based on the proposed method. The proposed relationship between SNR and KERMA entrance skin suggests that tubes with low energy photons have a low performance.
|
38 |
Avaliação automatica de parametros fisicos de qualidade de imagem em sistemas de radiologia digital odontologicaAlbuquerque, Jorge Andre Girão 29 July 2018 (has links)
Orientador : Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-29T02:59:46Z (GMT). No. of bitstreams: 1
Albuquerque_JorgeAndreGirao_M.pdf: 5796408 bytes, checksum: 09bd57e0a31a84f22f0e6c4d5ab05252 (MD5)
Previous issue date: 2001 / Mestrado
|
39 |
Estudo experimental da otimização em sistemas de mamografia digital CR e DR / Experimental study of optimization in CR and DR digital mammography systemsAlessandra Maia Marques Martinez Perez 29 January 2015 (has links)
A recente inserção e forte avanço da mamografia digital no Brasil como ferramenta de rastreamento do câncer mamário e as evidências de outras condições de otimização, quando comparadas à mamografia convencional (tela filme), requerem que novos parâmetros de qualidade sejam incluídos e estudados, bem como que as condições de otimização sejam revistas. O objetivo deste trabalho foi determinar a técnica radiográfica otimizada para dois sistemas de detecção (CR e DR) em uso em três unidades de mamografia: Mammomat 3000 Nova (Siemens), Senographe DMR (GE) e Senographe 2000D (GE). A otimização foi conduzida para uma variedade de combinações de fatores técnicos e configurações de simuladores de mama, tais como valores de kilovoltagem (26 a 32 kV), combinações anodo/filtro (Mo/Mo, Mo/Rh e Rh/Rh), material simulador de mama de várias espessuras (2 a 8 cm) e lesões simuladas como massas e calcificações, usando uma figura de mérito (FOM) como parâmetro. Verificou-se que o uso da combinação anodo/filtro que gera os espectros mais energéticos em cada equipamento proporcionou os maiores valores de FOM para todas as espessuras de simulador de mama e voltagens, devido a redução da dose. As combinações anodo/filtro que deram esses resultados foram Mo/Rh para o equipamento da marca Siemens e Rh/Rh para ambos os equipamentos da marca GE, correspondentes aos espectros mais energéticos de cada unidade. Foi observada ainda uma tendência de aumento do kV que maximiza FOM com o aumento da espessura. / The recent introduction and intense advance of digital mammography in Brazil as a tool in breast cancer screening and the evidences of new optimization conditions when compared to conventional mammography (screen-film) require adding and studying novel quality parameters, as well as revisiting optimization conditions. The objective of this work was to determine optimized radiographic technique for two detection systems (CR and DR) in use in three mammography units: Mammomat 3000 Nova (Siemens), Senographe DMR (GE) and Senographe 2000D (GE). Optimization was conducted for various combinations of technique factors and breast phantom configurations, such as kilovoltage settings (26 to 32 kV), target/filter combinations (Mo/Mo, Mo/Rh and Rh/Rh), breast equivalent material in various thicknesses (2 to 8 cm) and simulated mass and calcification lesions, using a figure of merit (FOM) as a parameter. When using anode/filter combination which generates higher energy spectra in each equipment, it was verified that higher FOM values were achieved for all voltages and phantom thicknesses, due to dose reduction. Anode/filter combinations which led to those results were Mo/Rh for Siemens equipment and Rh/Rh for both GE equipments, corresponding to the higher energy spectra in each unity. It was also observed an increasing tendency of kV which maximizes FOM with the increase of thickness.
|
40 |
O metodo de empilhamento CRS : refinamento dos parametros e aplicaçõesMajana, Farid 10 September 2003 (has links)
Orientador: Martin Tygel / Dissertação (mestrado) - Universidade Estadual de Cammpinas, Faculdade de Engenharia Mecanica, Instituto de Geociencias / Made available in DSpace on 2018-08-03T19:07:26Z (GMT). No. of bitstreams: 1
Majana_Farid_M.pdf: 5710235 bytes, checksum: 07e2341b42613d548d49d3d40bcd65d7 (MD5)
Previous issue date: 2003 / Resumo: o método da superfície comum de reflexão (CRS, do Inglês Common Rejlection Surface) é uma extensão do tradicional método NMO (do Inglês Normal MoveOut). Este permite somar ou empilhar traços dispostos em configurações mais gerais que as de ponto médio comum (CMP, do Inglês Commom MidPoint). Para tal propósito, o método CRS utiliza uma equação de tempo de trânsito generalizada, que depende da tradicional velocidade NMO e de outros parâmetros. Da mesma maneira que no método NMO, os parâmetros CRS são determinados a partir de uma análise de coerência nos dados de cobertura múltipla. A construção das seções simuladas de afas-tamento nulo requer três parâmetros no caso 2D. Este trabalho trata a estimação destes parâmetros e compara três algoritmos de otimização local aplicados ao refinamento dos parâmetros CRS. As comparações são feitas usando dados sintéticos e reais / Abstract: The common Reftection Surface (CRS) method extends the well established Normal Move-Out (NMO) method, allowing the stacking process to be applied to data arranged in settings more general than the common midpoint (CMP) gathers. For that aim, the CRS method uses the general hyperbolic moveout, which depends on the classical NMO velocity and some other parameters. As in the single-parameter NMO method, the CRS parameters are estimated applying a suitable coher-ence analysis to the multicoverage data. The construction of simulated (stacked) zero offset (ZO) sections in the 2D situation requires three CRS parameters. This work focuses on the estimation of these three parameters. It explains how the coherence analysis is performed by most imple-mentations of the CRS method and compares three algorithms used to refine the CRS parameters among themselves and with the traditional NMO method. These comparisons were performed using synthetic and real data / Mestrado / Reservatórios e Gestão / Mestre em Ciências e Engenharia de Petróleo
|
Page generated in 0.0676 seconds