• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 62
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 64
  • 64
  • 40
  • 36
  • 24
  • 14
  • 12
  • 12
  • 11
  • 11
  • 11
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analise comparativa das variações de tempos de exposição, tipo de processamento e do efeito da degradação das soluções processadoras na qualidade da imagem radiografica

Casanova, Marcia Leal Spinelli 02 August 2018 (has links)
Orientador: Francisco Haiter Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T19:32:46Z (GMT). No. of bitstreams: 1 Casanova_MarciaLealSpinelli_M.pdf: 6457913 bytes, checksum: 65052942539c07bd7dfb420a251ce972 (MD5) Previous issue date: 2002 / Resumo: O presente estudo teve como objetivo avaliar a variação no tempo de exposição, tipo de processamento e efeito da degradação das soluções processadoras na qualidade da imagem radiográfica, utilizando o filme Insight (IS-21), e comparando-o com o Ektaspeed Plus (EP 21-P), ambos da Kodak. Para isto os filmes foram expostos em variados tempos de exposição e processados, manual e automaticamente, em soluções de processamento novas e progressivamente degradadas. As comparações foram feitas a partir de análises densitométrica, subjetiva e construção de curvas características, tendo esta última permitido a avaliação das propriedades sensitométricas dos filmes. Os dados obtidos permitiram a constatação de que o filme Insight é mais sensível e menos susceptível à degradação dos líquidos de processamento do que o Ektaspeed Plus, ambos processados manual e automaticamente. O filme Insight permite uma redução da dose de radiação de 20% em relação ao Ektaspeed Plus sem prejuízos à qualidade da imagem radiográfica / Abstract: The aim of this research was to evaluate the variation of the exposure time, processing techniques and effect of the processing solution depletion in the image quality of the F-speed dental X-ray film (Insight), and to compare with Ektaspeed Plus, both from Kodak. The films were exposed in different exposure times and developed in manual and automatically conditions, in fresh and progressively depleted processing solutions. The comparison was based on densitometric analyze, subjective appraisals and on characteristics curves which allowed sensitometric properties evaluation. On the basis of the evaluation performed in this investigation, it was concluded that Insight is faster and more resistant than Ektaspeed Plus to the effects of the processing solution depletion, when processed in manual and automatically conditions. The exposure time for Insight can be reduced by 20% in comparison with Ektaspeed Plus at no detriment to image quality / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
2

Avaliação da qualidade da imagem e da dose no paciente em exames de radiografia panorâmica digital

Vanderley Brasileiro, Izabela 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T23:13:50Z (GMT). No. of bitstreams: 2 arquivo2671_1.pdf: 3459902 bytes, checksum: dcf2ef6ac9a4e650b22ffb4573954291 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A radiografia panorâmica é um importante método de diagnóstico por imagem, amplamente utilizado na odontologia. Embora as doses individuais e os riscos associados à radiografia panorâmica sejam considerados pequenos, a dose coletiva pode ser significativa, dado o elevado número de exames realizados. O objetivo deste trabalho foi efetuar um estudo dosimétrico de pacientes submetidos a exames de radiografia panorâmica digital, realizados em uma clínica radiológica do Recife e avaliar a qualidade da imagem destes exames. Foram estimados os valores do produto kerma-ar pelo comprimento (PK,L), do produto kerma-ar pela área (PK,A) e do kerma-ar na entrada da pele (Ke). Estes valores foram calculados utilizando os parâmetros de irradiação coletados de 310 pacientes adultos que realizaram exames de radiografia panorâmica na clínica com dois equipamentos Kodak 8000C (equipamentos 1 e 2). Os valores de PK,L foram obtidos através de medidas realizadas com câmara de ionização tipo lápis e a partir destes valores foi estimado o PK,A levando-se em consideração a área do campo de radiação. Os valores do Ke foram estimados utilizando dosímetros termoluminescentes posicionados sobre um fantoma de cabeça, em pontos correspondentes aos olhos, glândulas parótidas, nuca e tireóide. Para avaliação subjetiva da qualidade da imagem, foram coletadas de forma aleatória do banco de dados da clínica 200 imagens de pacientes, sendo 100 imagens de cada equipamento. Estas imagens foram avaliadas por dois radiologistas quanto à visualização de estruturas anatômicas, para determinação de um índice de qualidade da radiografia. Os valores médios encontrados para o PK,L e PK,A foram 6,9 mGy.cm e 82 mGy.cm2, respectivamente. Estes valores são similares aos encontrados na literatura e próximo ao nível de referência proposto no Reino Unido para paciente adulto. Em relação ao kerma-ar na entrada da pele, este foi mais elevado na região da nuca, cerca de quatro vezes maior que o valor das outras regiões avaliadas. Os resultados da avaliação de qualidade da imagem mostraram que o índice de qualidade das radiografias do equipamento 2 foi maior do que do equipamento 1. A partir dos resultados, conclui-se que os procedimentos podem ser ainda otimizados, principalmente para o equipamento 1, procurando-se aumentar o índice de qualidade e reduzir a dose no paciente
3

Avaliação da qualidade de imagem e do índice volumétrico de Kerma Ar em tomografia computadorizada (CVOL) em Recife

Ely Almeida Andrade, Marcos 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T23:16:06Z (GMT). No. of bitstreams: 2 arquivo8643_1.pdf: 3667345 bytes, checksum: e277fab80293f601f00fbe9b1fc04a3d (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A Tomografia Computadorizada (TC) é um importante método de diagnóstico por imagem, amplamente utilizado. Entretanto, apesar de suas vantagens e dos avanços tecnológicos que vêm ocorrendo com os equipamentos de TC, os procedimentos tomográficos resultam em altas doses absorvidas nos pacientes. O objetivo deste trabalho foi efetuar um estudo dosimétrico nos tomógrafos localizados na cidade do Recife e avaliar a qualidade da imagem em procedimentos tomográficos efetuados nestes equipamentos. Foram estimados o índice volumétrico de kerma ar em tomografia computadorizada (CVOL) e o produto kerma ar pelo comprimento de varredura (PKL,CT). Estes valores foram calculados utilizando índices normalizados de kerma ar ponderado em fantomas dosimétricos de TC (nCW), fornecidos pelo grupo ImPACT para diversos tomógrafos, e os parâmetros de irradiação para procedimentos tomográficos de crânio de rotina, tórax de rotina e tórax alta-resolução realizados em 20 instituições. Os parâmetros de irradiação de 15 pacientes adultos para cada procedimento foram registrados em seis instituições participantes do estudo, nas quais o fantoma do programa de acreditação em tomografia do Colégio Americano de Radiologia (ACR) foi utilizado para avaliar a qualidade da imagem. Para exames de crânio, os valores de CVOL variaram entre 12 e 58 mGy (para fossa posterior) e entre 15 e 58 mGy (para o cérebro) e os valores de PKL,CT, entre 150 e 750 mGycm. Valores de CVOL de varreduras de rotina do tórax variaram de 3 a 26 mGy, enquanto que o PKL,CT variou de 120 a 460 mGycm. Com relação aos exames de tórax em alta-resolução, o CVOL apresentou valores de 1,0 a 2,7 mGy e o PKL,CT, de 24 a 67 mGycm. Os resultados da avaliação de qualidade de imagem mostraram que quase todos os tomógrafos apresentaram pelo menos uma não conformidade. Um dos equipamentos apresentou falhas em 70% dos testes. Com relação ao ruído de imagem, apenas dois tomógrafos mostraram resultados aceitáveis. A partir deste estudo, conclui-se que os valores dos índices volumétricos de kerma ar em TC para os tomógrafos estudados estão abaixo dos níveis de referência europeus. Entretanto a qualidade de imagem destes equipamentos não atende a todos os requisitos do Colégio Americano de Radiologia, sugerindo a necessidade de implantação de programas de garantia de qualidade nas instituições avaliadas
4

Avaliação da qualidade de vídeo em comunicações móveis

Costa, Daniel Alexandre Delgado Gomes da January 2010 (has links)
Tese de mestrado integrado. Engenharia Electrotécnica e de Computadores (Major Telecomunicações). Faculdade de Engenharia. Universidade do Porto. 2010
5

Avaliação clínica de um sensor digital intra-oral

Corrêa, Leticia Ruhland January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-22T09:01:59Z (GMT). No. of bitstreams: 1 228903.pdf: 1408724 bytes, checksum: 24f3fd22fc7fd9dbc5c9e3b29d5260d4 (MD5) / O presente trabalho teve como objetivo comparar, através da realização de exames radiográficos periapicais completos, um sensor digital e o filme radiográfico convencional em quatro quesitos: número e tipos de erros observados nas imagens radiográficas obtidas, qualidade geral das imagens, grau de conforto ou desconforto experimentado pelos pacientes durante os exames e o tempo necessário para a realização das aquisições radiográficas com os dois sistemas. Exames radiográficos periapicais completos foram realizados por três radiologistas, em quarenta e cinco pacientes, utilizando-se filme e sensor em quadrantes cruzados, perfazendo um total de 360 radiografias convencionais e 450 digitais. O tempo de realização de cada tomada radiográfica foi cronometrado. Os pacientes foram questionados, durante a realização dos exames, quanto ao grau de conforto ou desconforto experimentado nas diferentes regiões radiografadas. Um painel de 3 radiologistas analisou as imagens quanto ao número e tipos de erros contidos nas imagens e quanto à qualidade geral das mesmas. Um maior número de erros foi observado com o uso do sensor digital quando comparado ao filme (p< 0,0001). A análise por regiões dentais demonstrou haver diferença estatisticamente significativa nas regiões de 2° molar superior, 1° molar superior, incisivos superiores, canino inferior e incisivos inferiores (p< 0,05). Houve diferença estatisticamente significativa entre o sensor digital e filme (p< 0,001) no quesito "qualidade geral" das imagens, sendo que um maior número de imagens radiográficas de melhor qualidade foi obtido com o uso do filme. Fazendo-se a individualização das regiões dentais, houve diferença estatisticamente significativa na qualidade geral das radiografias nas regiões de 2° molar superior, canino superior, incisivos superiores, 2° molar inferior, canino inferior e incisivos inferiores. (p< 0,05). Houve diferença estatisticamente significativa entre o sensor digital e o filme quanto ao grau de conforto ou desconforto com os dois sistemas (p< 0,001), sendo que o sensor digital se mostrou mais desconfortável do que o filme. Houve diferença estatisticamente significativa nas regiões 2° molar superior, canino superior e incisivos superiores, onde o filme se mostrou mais confortável que o sensor (p< 0,05). Em relação ao tempo necessário para a realização das aquisições radiográficas, observou-se que não houve diferença entre as modalidades (0,502). Os resultados permitiram concluir que: a) o uso de filme radiográfico convencional resulta em um menor número de erros quando comparado ao uso de um sensor digital na realização de exames radiográficos periapicais; b) o uso de filme radiográfico convencional resulta em imagens radiográficas de melhor qualidade geral quando comparado às imagens obtidas com o sensor digital na realização de exames radiográficos periapicais; c) o filme radiográfico convencional é menos desconfortável para o paciente que um sensor digital na realização de exames radiográficos periapicais; e d) que o tempo necessário para a realização de aquisições radiográficas periapicais com um sensor digital é semelhante ao requerido pelo filme convencional. The aim of the present study was to compare the clinical use of a digital sensor and conventional film, through the realization of full mouth periapical examinations, in four points: number and types of errors observed in the images, quality of the images, degree of patient comfort or discomfort during the examinations and the necessary time for taking the images with the two systems. Complete periapical examinations were obtained of forty-five patients using a digital sensor and film using a crossed split-mouth design, in a total of 360 conventional x-rays and 450 digital images. The operating time to position and expose the receptor was registered. The images were evaluated by a panel of three dental radiologists for the number and types of errors. Each radiograph was also given an overall rating as excellent, good, acceptable or unacceptable. A higher number of errors were observed with the use of the digital sensor when compared with film (p< 0,0001). The digital sensor showed more errors than film in the regions of upper second molar, upper first molar, upper incisors, lower canine and lower incisors (p< 0,05). The film had images with more quality in the regions of upper second molar, upper canine, upper incisors, second lower molar, lower canine and lower incisors (p< 0,05) Patients felt film more comfortable in the regions of upper second molar, upper canine and upper incisors. Operating time was similar between digital sensor and film (p= 0,502). It can be concluded that: a) the use of conventional film results in a lower number of errors and b) the use of conventional film results in radiographic images of better quality when compared with the use of a digital sensor in the accomplishment of periapical examinations; c) film is more comfortable for the patient than a digital sensor in periapical examinations; e d) the necessary time for the accomplishment of periapical images with a digital sensor is similar to that required for film.
6

Comparação das razões lineares das vértebras cervicais por tomografia computadorizada de feixe cônico (TCFC)

Mendonça, Tássia Mara Fernandes [UNESP] 16 July 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-16Bitstream added on 2014-06-13T20:19:06Z : No. of bitstreams: 1 mendonca_tmf_me_sjc.pdf: 633971 bytes, checksum: 75c31ab01e3f40e3d075fbf6ff0822ad (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo teve como objetivo avaliar possíveis diferenças das razões lineares da segunda e da terceira vértebras cervicais em cinco estágios do surto de crescimento puberal (SCP) avaliadas por tomografia computadorizada de feixe cônico (TCFC). Foram selecionados 26 exames de TCFC e as respectivas radiografias de mão e punho, de pacientes do sexo masculino e do feminino, com idades entre 8 e 18 anos e 11 meses. A amostra selecionada foi dividida em cinco grupos de acordo com os eventos de ossificação presentes nas radiografias de mão e punho, seguindo a curva de crescimento proposta por Martins e Sakima (1977), modificada por Mercadante (1996). Os exames tomográficos foram analisados por meio do próprio software do equipamento I-Cat® sob a extensão de arquivo “xstd”. De posse do plano sagital ajustado ao protocolo de imagem foram realizadas, de forma objetiva, as mensurações das vértebras C2 e C3, por meio de onze pontos, a partir dos quais oito distâncias lineares foram obtidas. Baseados nestas, foram calculadas quatro razões, sendo uma de C2 e o restante de C3. Para verificar a existência de diferenças entre as razões obtidas para os cinco grupos da curva de crescimento, foi realizado o teste estatístico de análise de variância (Anova), fator único, associado ao teste de homogeneidade de Tukey para caracterizar cada fase do SCP. O nível de significância adotado foi de 95% para todas as análises. Verificou-se que o método é reprodutível (r2=0,994), sendo crescente as razões C2R, C3R e AL conforme as fases do SCP. Já para ASAP, observou-se aumento apenas nas fases 1, 3 e 5. De acordo com os resultados obtidos foi possível concluir que houve diferenças estatisticamente... / This study aimed to evaluate possible differences of linear ratios of the second and third cervical vertebrae in five stages of pubertal growth spurt (PGS) evaluated by cone beam computed tomography (CBCT). A total of 26 CBCT scans and their hand and wrist radiographs of males and females, aged between 8 and 18 years and 11 months. The sample was divided into five groups according to the events of ossification present in the hand and wrist radiographs, following the curve of growth proposed by Martins and Sakima (1977), modified by Mercadante (1996). CT scans were analyzed using the software itself I-Cat ® equipment under the file extension xstd. Having the sagittal image adjusted to the protocol were performed in an objective way, measurements of C2 and C3, by eleven points, from which eight linear distances were obtained. Based on these, four were calculated reasons, one of C2 and C3 of rest. To check for differences between the ratios obtained for the five groups of the growth curve was performed to test statistical analysis of variance (ANOVA) single factor associated with the Tukey’s test of homogeneity to characterize each phase of the PGS. It was found that the method is reproducible (r2 = 0.994), with increasing ratios C2R, and AL C3R as phases of SCP. As for ASAP, growth observed only stages 1, 3 and 5. According to the results we conclude that statistically significant differences between the... (Complete abstract click electronic access below)
7

Comparação das razões lineares das vértebras cervicais por tomografia computadorizada de feixe cônico (TCFC) /

Mendonça, Tássia Mara Fernandes. January 2012 (has links)
Orientador: Luiz Cesar de Moraes / Co-orientador: Luiz Roberto Coutinho Manhães Junior / Banca: Mauro Pedrine Santamaria / Banca: Jorge Abrão / Resumo: Este estudo teve como objetivo avaliar possíveis diferenças das razões lineares da segunda e da terceira vértebras cervicais em cinco estágios do surto de crescimento puberal (SCP) avaliadas por tomografia computadorizada de feixe cônico (TCFC). Foram selecionados 26 exames de TCFC e as respectivas radiografias de mão e punho, de pacientes do sexo masculino e do feminino, com idades entre 8 e 18 anos e 11 meses. A amostra selecionada foi dividida em cinco grupos de acordo com os eventos de ossificação presentes nas radiografias de mão e punho, seguindo a curva de crescimento proposta por Martins e Sakima (1977), modificada por Mercadante (1996). Os exames tomográficos foram analisados por meio do próprio software do equipamento I-Cat® sob a extensão de arquivo "xstd". De posse do plano sagital ajustado ao protocolo de imagem foram realizadas, de forma objetiva, as mensurações das vértebras C2 e C3, por meio de onze pontos, a partir dos quais oito distâncias lineares foram obtidas. Baseados nestas, foram calculadas quatro razões, sendo uma de C2 e o restante de C3. Para verificar a existência de diferenças entre as razões obtidas para os cinco grupos da curva de crescimento, foi realizado o teste estatístico de análise de variância (Anova), fator único, associado ao teste de homogeneidade de Tukey para caracterizar cada fase do SCP. O nível de significância adotado foi de 95% para todas as análises. Verificou-se que o método é reprodutível (r2=0,994), sendo crescente as razões C2R, C3R e AL conforme as fases do SCP. Já para ASAP, observou-se aumento apenas nas fases 1, 3 e 5. De acordo com os resultados obtidos foi possível concluir que houve diferenças estatisticamente... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to evaluate possible differences of linear ratios of the second and third cervical vertebrae in five stages of pubertal growth spurt (PGS) evaluated by cone beam computed tomography (CBCT). A total of 26 CBCT scans and their hand and wrist radiographs of males and females, aged between 8 and 18 years and 11 months. The sample was divided into five groups according to the events of ossification present in the hand and wrist radiographs, following the curve of growth proposed by Martins and Sakima (1977), modified by Mercadante (1996). CT scans were analyzed using the software itself I-Cat ® equipment under the file extension "xstd." Having the sagittal image adjusted to the protocol were performed in an objective way, measurements of C2 and C3, by eleven points, from which eight linear distances were obtained. Based on these, four were calculated reasons, one of C2 and C3 of rest. To check for differences between the ratios obtained for the five groups of the growth curve was performed to test statistical analysis of variance (ANOVA) single factor associated with the Tukey's test of homogeneity to characterize each phase of the PGS. It was found that the method is reproducible (r2 = 0.994), with increasing ratios C2R, and AL C3R as phases of SCP. As for ASAP, growth observed only stages 1, 3 and 5. According to the results we conclude that statistically significant differences between the... (Complete abstract click electronic access below) / Mestre
8

Metodologia para otimização de protocolo PET/CT harmonizado de baixa dose em tumores sólidos com reconstrução Point Spread Function

MACHADO, Marcos Antônio Dórea 10 February 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-07-20T22:10:35Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Marcos Antônio Dórea Machado.pdf: 2233914 bytes, checksum: b98eee9403ebcdd88d55481bc0692500 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-07-23T17:59:48Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Marcos Antônio Dórea Machado.pdf: 2233914 bytes, checksum: b98eee9403ebcdd88d55481bc0692500 (MD5) / Made available in DSpace on 2018-07-23T17:59:48Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Marcos Antônio Dórea Machado.pdf: 2233914 bytes, checksum: b98eee9403ebcdd88d55481bc0692500 (MD5) Previous issue date: 2017-02-10 / O equipamento PET, os parâmetros de aquisição e a reconstrução de imagens em exames oncológicos de PET têm impacto tanto na qualidade das imagens quanto na quantificação da atividade metabólica dos tumores. Neste trabalho é apresentado um método para otimizar os parâmetros de aquisição de imagens em exames FDG-F18 PET/CT de tumores sólidos, a partir do ruído no simulador IEC/NEMA e na região do fígado de 88 pacientes. O algoritmo de reconstrução Point Spread Function (PSF), harmonizado de acordo com os critérios da European Association of Nuclear Medicine (EANM), foi usado para gerar imagens superiores em termos de ruído. Assim, as medidas de ruído no simulador IEC/NEMA foram correlacionadas às quantificações dos coeficientes de recuperação de contraste máximos (CRCmax), em que os limites adotados pela EANM para CRCmax foram usados como critérios de qualidade que definem a relação ótima entre parâmetros de aquisição, ruído e quantificações. Adicionalmente, o ruído na região do fígado de 48 pacientes foi caracterizado para as reconstruções OSEM e PSF (CRCmáx harmonizados) com densidades de contagens tipicamente usadas em uma rotina clínica. Outro conjunto de 40 imagens em modo lista da região do fígado de pacientes foi usado para gerar 160 imagens com um amplo espectro de densidade de contagens, a fim de compreender o ruído em diferentes contextos de densidade de contagens. Aquisição de imagens com aproximadamente 350 MBq.s/kg no simulador IEC/NEMA apresentou variabilidade da quantificação em conformidade aos limites da EANM, que corresponde a um ruído no simulador de CV = 8,7%. Este mesmo parâmetro de aquisição quando aplicado a um paciente, resulta em um ruído de CV = 7,1% na região do fígado, que pode ser usado como uma medida de garantia da qualidade na rotina de exames. Entretanto, a região entre 200-320 MBq.s/kg sugere oferecer quantificações de SUVmáx reprodutíveis pois o ruído no fígado mostrou-se controlado nesta região de densidade de contagens. O uso do SUVpeak mostrou-se ainda mais reprodutível, incluindo a região entre 100-200 MBq.s/kg. Este método representa a base para um estudo que possa identificar o protocolo de aquisição otimizado, para vários equipamentos e tipos de reconstrução, a fim de executar exames de PET/CT com baixa posologia atendendo aos critérios de harmonização da EANM. / The PET/CT scanner, the image acquisition and the reconstruction parameters in oncological PET affect the image quality and the quantification of tumor activity. In this work, we presented a method for image acquisition optimization of FDG-F18 PET/CT examinations in solid tumors by using noise metrics in the IEC/NEMA phantom and in the liver of 88 subjects. The Point Spread Function (PSF) reconstruction algorithm, harmonized according to he European Association of Nuclear Medicine (EANM), was used to generate superior images in terms of noise. Then, we used the IEC/NEMA phantom to correlate noise and maximum contrast recovery coefficient (CRCmáx) quantitation measurements which the EANM CRCmáx limits were adopted as criteria to define the optimal relations among acquisition parameters, noise and quantification. Additionally, the noise in the liver of 48 subjects was characterized for OSEM and PSF reconstructions (CRCmáx harmonized) by using clinical count densities typically used in clinical routine. Another set of 40 list mode images from the liver was used to generate 160 images with a wide range count density spectrum in order to understand the noise characteristics in different count density context. Image acquisitions of about 350 MBq.s/kg in the IEC/NEMA phantom presented CRCmáx variability within EANM limits, which corresponds to 8.7% noise in phantom. Such image acquisition parameter provides 7.1% noise in the liver, which might be used as a quality assurance measurement in clinical routine. However, the 200-320 MBq.s/kg range may pose reproducible SUVmáx quantitation since noise in liver was satisfactorily controlled for such count density spectrum. When SUVpeak was used, it presented even better reproducibility, including the 100-200 MBq.s/kg spectrum. The presented method provides the basis to more robust studies to identify the optimal acquisition parameter for different scanners and reconstructions in order to perform low-dose FDF-F18 PET/CT according to EANM harmonization criteria.
9

Estudo comparativo das analises subjetiva e objetiva de quatro sistemas radiograficos digitais intrabucais

Oliveira, Ana Emilia Figueiredo de 17 July 2001 (has links)
Orientador : Frab Norberto Boscolo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T16:58:21Z (GMT). No. of bitstreams: 1 Oliveira_AnaEmiliaFigueiredode_D.pdf: 10687207 bytes, checksum: 87989b4029d419522329601c38b34367 (MD5) Previous issue date: 2001 / Resumo: O objetivo no presente trabalho foi a realização de uma análise conjunta, subjetiva e objetiva, da qualidade de imagem de quatro sistemas radiográficos digitais intrabucais, visando correlacionar seus resultados. Empregou-se dois sistemas de armazenamento de fósforo, Digora e DenOptix, e dois sistemas CCD, CDR e Sens-A-Ray. Na análise clínica, utilizou-se como objetos de estudo quatro regiões anatômicas dentais e uma escala de densidade de alumínio, que foram avaliadas por seis radiologistas, num total de 280 imagens. A análise objetiva foi realizada por meio de um Sistema Integrado, composto de phantoms específicos e um pacote computacional, que propiciaram a estimativa automática dos parâmetros físicos em 2050 imagens. Os resultados permitiram. que se concluísse que, em ambas análises, os sistemas de armazenamento de fósforo se apresentaram, de uma forma geral, com um melhor desempenho que os sistemas CCD. O Digora apresentou-se como o sistema de melhor performance física, e o Sens-A-Ray como o sistema de mais baixo desempenho. Existiu uma forte relação entre os resultados de ambas análises, excetuando-se os referentes à resolução espacial e ao MTF, onde se pôde concluir, que o "padrão ouro" para relacionar com eficiência os parâmetros físicos e a qualidade de diagnóstico dos sistemas radiográficos digitais é a análise conjunta do DQE, do SNR e do contraste da imagem / Abstract: The objective of the present work was the accomplishment of a subjective and objective analysis of the image quality of four digital intra-oral radiographic systems, aiming at to correlate its results. It was used two storage phosphor systems, Digora and DenOptix, and two CCD systems, CDR and Sens-A-Ray. In the clinical analysis, it was used as study object four dental anatomical regions and an aluminum stepwedge, that had been analyzed by six radiologist, in a total of 280 images. The objective analysis was carried through by means of an Integrated System, composed by specific phantoms and a computational package that got possible the automatic estimate of the physical parameters in more than 2000 images. The results had shown that, in both analyses, the storage phosphor systems had presented, of a general form, a better performance than CCD systems. The Digora system presented the best physical performance, with the Sens-A-Ray behaving with the lowest results. There was a strong relation between the results of both analyses, excepting itself referring the space resolution and to the MTF, where it could be concluded that the "gold pattern" to relate with efficiency the physical parameters and the capacity of diagnosis of the digital radiographic systems is the joint analysis of the DQE, the SNR and the contrast of the image / Doutorado / Radiologia Odontologica / Doutor em Radiologia Odontológica
10

Analise da qualidade de imagens obtidas em sensores do sistema DenOptix parcialmente dessensibilizados

Lopes, Sergio Lucio Pereira de Castro 09 September 2002 (has links)
Orientador : Solange Maria de Almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T16:25:53Z (GMT). No. of bitstreams: 1 Lopes_SergioLucioPereiradeCastro_M.pdf: 3060860 bytes, checksum: e901411ca2ec98db5bad48fc901f3204 (MD5) Previous issue date: 2002 / Resumo: O presente trabalho teve como objetivo avaliar a qualidade das Imagens do Sistema radiográfico digital DenOptix®, obtidas através de sensores parcialmente dessensibilizados. Para tal objetivo, foi utilizado no processo, um negatoscópio cujo tempo necessário para a total dessensibilização dos sensores já era conhecido previamente e igual a 130 segundos. Foram determinados tempos parciais de dessensibilização a serem estudados e então obtidas imagens de 10 diferentes segmentos de mandíbulas humanas maceradas, com dose de radiação fixa igual a 840 µGy. De cada um destes, obteve-se dez imagens diferentes, correspondentes aos tempos de dessensibilização a serem estudados, sumarizando no total 100 imagens. Estas foram montadas em pares, onde uma era sempre aquela obtida com o sensor totalmente dessensibilizado e a outra com tempo de dessensibilização a ser estudado. Estes pares, no total de 100, foram analisados por cinco radiologistas, que foram orientados em escolher, de cada par, apenas uma imagem como a de melhor qualidade. Após a análise estatística dos dados, concluiu-se que a dessensibilização parcial de sensores DenOptix, abaixo do tempo preconizado, não evidenciou a presença de ruído nas mesmas. Nestes grupos, não houve diferenças estatisticamente significantes entre as escolhas de imagens de sensores totais e parcialmente dessensibilizadas. Apenas nos grupos em que a imagem era obtida em sensor não dessensibilizado (zero segundo) houve alterações na qualidade das imagens detectadas pelos avaliadores / Abstract: The aim of the present work was to evaluate the DenOptix System images quality, when obtained in partially erased imaging plates. For this goal, was used to erase the imaging plate a lightbox, with erasing time of 130 seconds. Partially erasing times were chosen to be evaluated and then images from 10 diferents human jaw pieces were used, with a radiation dose of 840µGy. In each one of the pieces were taken 10 different kinds of images regarding of the erasing times to be evaluated, 100 images were taken, in total. These images were assembled in pairs, where one was that gotten in an imaging plate totally erased (130 seconds) and the other one was that gotten in a different erasing time. Five dental radiologists, who were said to choose just one image, in each pair, as the best one, analyzed these pairs, in total 100. After statistics studies, the study conc1udedthat images obtained from partially erasing plates, didn't evidence noise. In these groups, there was no significant statistic difference between the choice of total and partially erased images plates as the responsible to show the best image. Just on the groups where the images were obtained from non erased imaging plates (zero seconds) there were quality image changes / Mestrado / Mestre em Radiologia Odontológica

Page generated in 0.1379 seconds