• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 53
  • 2
  • 1
  • Tagged with
  • 56
  • 23
  • 21
  • 15
  • 11
  • 9
  • 7
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Estudo do pior caso na validação de limpeza de equipamentos de produção de radiofármacos de reagentes liofilizados. Validação de metodologia de carbono orgânico total / Worst-case study for cleaning validation of equipments in the radiopharmaceutical production of lyophilized reagents. Metodology validation of total organic carbon.

Luciana Valeria Ferrari Machado Porto 18 December 2015 (has links)
Os radiofármacos são definidos como preparações farmacêuticas contendo um radionuclídeo em sua composição, são administrados intravenosamente em sua maioria, e, portanto, o cumprimento dos princípios de Boas Práticas de Fabricação (BPF) é essencial e indispensável à tais produtos. A validação de limpeza é um requisito das BPF e consiste na evidência documentada que demonstra que os procedimentos de limpeza removem os resíduos a níveis pré-determinados de aceitação, garantindo que não haja contaminação cruzada. Uma simplificação da validação dos processos de limpeza é admitida, e consiste na escolha de um produto, denominado de \"pior caso\" ou worst case, para representar a limpeza de todos os equipamentos da mesma linha de produção. Uma das etapas da validação de limpeza é o estabelecimento e validação do método analítico para quantificação do resíduo. O objetivo deste estudo foi estabelecer o pior caso para a validação de limpeza dos equipamentos de produção de reagentes liofilizados-RL para marcação com 99mTc, avaliar a utilização do teor de carbono orgânico total (COT) como indicador de limpeza dos equipamentos utilizados na fabricação dos RL, validar o método para determinação de CONP (carbono orgânico não purgável/volátil) e realizar testes de recuperação com o produto escolhido como pior caso. A escolha do produto pior caso baseou-se no cálculo de um índice denominado \"índice para pior caso - Worst Case Index (WCI)\", utilizando informações de solubilidade dos fármacos, dificuldade de limpeza dos equipamentos e taxa de ocupação dos produtos na linha de produção. O produto indicado como pior caso entre os RL foi o MIBI-TEC. Os ensaios de validação do método foram realizados utilizando-se um analisador de carbono modelo TOC-Vwp acoplado a um amostrador automático modelo ASI-V, ambos da marca Shimadzu&reg e controlados por software TOC Control-V Shimadzu&reg. Foi utilizado o método direto de quantificação do CONP. Os parâmetros avaliados na validação do método foram: conformidade do sistema, robustez, linearidade, limites de detecção (LD) e de quantificação (LQ), precisão (repetibilidade e precisão intermediária), e exatidão (recuperação) e foram definidos como: 4% acidificante, 2,5 mL de oxidante, tempo de integração da curva de 4,5 minutos, tempo de sparge de 3,0 minutos e linearidade na faixa de 40-1000 μgL-1, com coeficiente de correlação (r) e soma residual dos mínimos quadrados (r2) > 0,99 respectivamente. LD e LQ para CONP foram 14,25 ppb e 47,52 ppb, respectivamente, repetibilidade entre 0,11 4,47%; a precisão intermediária entre 0,59 a 3,80% e exatidão entre 97,05 - 102,90%. A curva analítica para Mibi mostrou-se linear na faixa de 100-800 μgL-1, com r e r2 > 0,99, apresentando parâmetros similares aos das curvas analíticas de CONP. Os resultados obtidos neste estudo demonstraram que a abordagem do pior caso para validação de limpeza é um meio simples e eficaz para diminuir a complexidade e morosidade do processo de validação, além de proporcionar uma redução nos custos envolvidos nestas atividades. Todos os resultados obtidos nos ensaios de validação de método CONP atenderam as exigências e especificações preconizadas pela norma RE 899/2003 da ANVISA para considerar a metodologia validada. / Radiopharmaceuticals are defined as pharmaceutical preparations containing a radionuclide in their composition, mostly intravenously administered, and therefore compliance with the principles of Good Manufacturing Practices (GMP) is essential and indispensable. Cleaning validation is a requirement of the current GMP, and consists of documented evidence, which demonstrates that the cleaning procedures are able to remove residues to pre-determined acceptance levels, ensuring that no cross contamination occurs. A simplification of cleaning processes validation is accepted, and consists in choosing a product, called \"worst case\", to represent the cleaning processes of all equipment of the same production area. One of the steps of cleaning validation is the establishment and validation of the analytical method to quantify the residue. The aim of this study was to establish the worst case for cleaning validation of equipment in the radiopharmaceutical production of lyophilized reagent (LR) for labeling with 99mTc, evaluate the use of Total Organic Carbon (TOC) content as indicator of equipment cleaning used in the LR manufacture, validate the method of Non-Purgeable Organic Carbon (NPOC), and perform recovery tests with the product chosen as worst case.Worst case products choice was based on the calculation of an index called \"Worst Case Index\" (WCI), using information about drug solubility, difficulty of cleaning the equipment and occupancy rate of the products in line production. The products indicated as worst case was the LR MIBI-TEC. The method validation assays were performed using carbon analyser model TOC-Vwp coupled to an autosampler model ASI-V, both from Shimadzu&reg, controlled by TOC Control-V software. It was used the direct method for NPOC quantification. The parameters evaluated in the validation method were: system suitability, robustness, linearity, detection limit (DL) and quantification limit (QL), precision (repeatability and intermediate precision), and accuracy (recovery) and they were defined as follows: 4% acidifying reagent, 2.5 ml oxidizing reagent, 4.5 minutes integration curve time, 3 minutes sparge time and linearity in 40-1000 μgL-1 range, with correlation coefficient (r) and residual sum of minimum squares (r2) greater than 0.99 respectively. DL and QL for NPOC were 14.25 ppb e 47.52 ppb respectively, repeatability between 0.11 and 4.47%; the intermediate precision between 0.59 and 3.80% and accuracy between 97.05 and 102.90%. The analytical curve for Mibi was linear in 100-800 μgL-1 range with r and r2 greater than 0.99, presenting similar parameters to NPOC analytical curves. The results obtained in this study demonstrated that the worst-case approach to cleaning validation is a simple and effective way to reduce the complexity and slowness of the validation process, and provide a costs reduction involved in these activities. All results obtained in NPOC method validation assays met the requirements and specifications recommended by the RE 899/2003 Resolution from ANVISA to consider the method validated.
52

Estudo de rotas de purificação em processos de produção de Mo-99 e I-131 de fissão / Study of purification routes in production processes of fission Mo-99 and I-131

Damasceno, Marcos Oliveira 25 April 2019 (has links)
Neste trabalho foram avaliadas novas rotas de purificação de Mo-99 e I-131 de fissão, por meio de associações inovadoras de técnicas clássicas de purificação química, presentes nos principais processos produtivos destes radioisótopos. Os processos de purificação estudados totalizaram seis combinações diferentes, divididas em dois grupos de três rotas. Foram utilizadas técnicas de cromatografia em coluna, destilação (seca e úmida), precipitação seletiva e extração por solvente. Todas as rotas utilizaram como ponto de partida uma coluna de resina aniônica, responsável por importante etapa de descontaminação, além da separação do Mo-99 e I-131. Nas etapas seguintes, as demais técnicas foram aplicadas de acordo com as configurações de cada rota. As rotas com coluna quelante e com sistema de extração por solvente apresentaram os melhores resultados de purificação para o Mo-99 (84,4%) e o I-131 (74,9%) respectivamente. Os resultados foram comparados em termos de eficiência de recuperação dos radioisótopos, grau de descontaminação e viabilidade operacional em processos de produção. As rotas de melhor desempenho apresentam potencial em termos de aprimoramentos de eficácia e aspectos operacionais, por meio de estudos em maior escala, além de poderem fornecer parâmetros para a construção de celas-piloto de Mo-99 e I-131. / In this work new purification routes of Mo-99 and I-131 fission were evaluated through innovative associations of classical chemical techniques of purification used by the main productive procedures of these radioisotopes. These purification routes were studied using six different combinations of techniques, divided into two groups of three routes. Column chromatography, distillation (dry and wet), selective precipitation and solvent extraction were the techniques applied in this investigation. In all routes, the first step was performed using a column of anionic resin in an important decontamination step, besides the separation of Mo-99 and I-131. In the following steps, other techniques were applied according to the methodology of each route. Chelating column and solvent extraction system showed the best purification results for Mo-99 (84.4 %) and I-131 (74.9 %), respectively. The final results were compared considering radioisotope recovery, decontamination degree and operational feasibility. The best-performing routes presented possibilities for improvements in efficiency and operational aspects, through larger-scale studies. Moreover, parameters for the construction of Mo-99 and I-131 mock-up cells were provided.
53

Avaliação do perfil dos resíduos de serviços de saúde de Belo Horizonte quanto à presença de rejeitos radioativos na destinação final / Evaluation of the waste profile from (medical) health services of Belo Horizonte concerned to the presence of radioactive wastes in the disposal system

Adirson Monteiro de Castro 15 March 2005 (has links)
Nenhuma / Os procedimentos médicos de diagnóstico e tratamento que utilizam radiofármacos geram rejeitos radioativos que, após decaírem até o limite de eliminação, podem ser destinados pelas vias convencionais de coleta e disposição final de Resíduos Sólidos Urbanos RSU. O objetivo da pesquisa foi detectar radiometricamente a presença de rejeitos radioativos nos resíduos de serviços de saúde destinados à disposição final. Ressalta-se que o limite legal de eliminação para rejeitos sólidos estabelecido pela Comissão Nacional de Energia Nuclear CNEN é de 7,5 x 104 Bq/kg (2 Ci/kg). As medições foram feitas no conteúdo de 25 caminhões da coleta especial de Resíduos de Serviços de Saúde (RSS), no aterro sanitário de Belo Horizonte, utilizando-se um cintilômetro de iodeto de sódio. Em 60% dos casos foram encontrados valores acima do limite estabelecido. A análise espectral de 6 amostras revelou a presença do radionuclídeo tecnécio-99m (99mTc), em 5 delas, e de eodo-131 (131I), em um caso. Estes elementos, tecnécio-99m (99mTc) e iodo-131 (131I), são os mais utilizados em procedimentos de Medicina Nuclear. Conclui-se que está havendo liberação de rejeito radioativo com os de Resíduos de Serviços de Saúde (RSS), devido a inobservância do tempo de decaimento até obtenção dos níveis legalmente permitidos para liberação. / The medical procedures of diagnosis and treatment that use radiopharmaceuticals generate radioactive wastes that can, after reaching the release limit, follow the conventional ways of collection and disposal of the urban solid wastes. This research aims to detect radiometrically the presence of radioactive wastes in the health-care wastes at the final disposal. It is pointed out that the legal limit for the release of solid wastes established by Brazilian National Commission of Nuclear Energy (CNEN) is 7,5x104 Bq/kg (2 Ci/kg). Measurements in the material of the garbage trucks that make the special collect from Health Service installations are performed, at Belo Horizonte sanitary landfill, using a NaI scintillation counter. Values above the established limit were found in 60% of the cases. The spectral analysis of 6 samples showed the presence of 99mTc in 5 of them and 131I in one. These radionuclides are the most common radionuclides used in Nuclear Medicine. In conclusion there are radioactive wastes released together with the health service wastes, due to the disregard of the decay time until the legal limit is achieved.
54

Produção de 18F-Fluorocolina no Centro de Desenvolvimento da Tecnologia Nuclear: síntese e estudos de citotoxicidade in vitro / Produção de 18F-Fluorocolina no Centro de Desenvolvimento da Tecnologia Nuclear: síntese e estudos de citotoxicidade in vitro / 18F-fluorocholine production at Center of Nuclear Technology Development: synthesis and in vitro citotoxicity studies / 18F-fluorocholine production at Center of Nuclear Technology Development: synthesis and in vitro citotoxicity studies

Flávia Mesquita Costa 06 June 2014 (has links)
A 18FCH é um biomarcador promissor para imagem de tumores usando a tecnologia PET, sendo eficaz no diagnóstico de tumores metastáticos e específico para tumores cerebrais, de próstata, de pulmão, entre outros. Apesar de já ser utilizada em alguns países como na França, Alemanha, Eslovênia, Polônia, România e Portugal, a 18FCH ainda não é produzida nem comercializada no Brasil. Este trabalho propôs o desenvolvimento de um novo radiofármaco baseado em colina marcada com o isótopo 18F para diagnóstico de imagens PET por ser uma demanda crescente na medicina nuclear nacional. Também foi proposto o desenvolvimento de ensaios para o controle de qualidade de modo a avaliar o radiofármaco antes de sua utilização em pacientes; testes in vitro de toxicidade em células não tumorais (MRC-5), avaliando possíveis alterações na proliferação celular causadas pelas impurezas do radiofármaco; e, testes de saturação da interação da 18FCH com células tumorais (PC-3 e U-87) e a competição com HC-3 e DMAE, realizados para caracterizar a eficiência da captação do radiofármaco por células tumorais que expressam o transportador de colina CHT. A 18FCH foi sintetizada por duas etapas principais, a primeira pela reação do dibromometano com fluoreto-18, assistida por Kryptofix2.2.2, formando o 18F-fluorobromometano (18FBrCH2) e, em seguida, o 18FBrCH2 reagiu com o segundo precursor, DMAE, gerando o produto final,18FCH. O tempo de síntese foi de 45 minutos. A 18FCH foi obtida com rendimento radioquímico de 4,68 a 8,32%, pureza radioquímica maior que 99% e mostrou-se estável por até 8 horas após a sua produção. As metodologias analíticas testadas foram adequadas para o uso rotineiro no controle de qualidade da 18FCH. A avaliação do potencial citotóxico das impurezas da 18FCH, pelo teste clonogênico, mostrou que, nas concentrações avaliadas, os componentes não alteram a capacidade proliferativa das células sadias humanas. A interação da 18FCH com as linhagens celulares foi saturável, com ligação específica maior que 94%, atestando a eficácia do radiofármaco. O HC-3 e DMAE mostraram significativa inibição da captação do radiofármaco, demonstrando que, sua captação nestas células ocorre parcialmente, pelo transportador CHT. Os valores de IC50 para HC-3 foram de 795,9+ 221,1; 409,3 + 353,6 e 778,4 + 95,3M para PC-3, U-87 e MRC-5, respectivamente e para DMAE foram de 11,0 + 8,7; 4,7 + 1,2 e 6,3 + 2,2M para PC-3, U-87 e MRC-5, respectivamente, mostrando-se potentes inibidores da captação da colina. Todos os testes realizados contribuíram, em parte, para o processo de registro conforme normas da ANVISA.
55

Estudo, desenvolvimento e construção de célula multipropósito para produção de radiofármacos, em acordo com parâmetros e padrões de Boas Práticas de Fabricação (BPF) / Study, development and assembling of a multipurpose hot cell for radiopharmaceuticals production in accordance with the Good Manufacturing Practices (GMP) requirements

Campos, Fábio Eduardo de 10 December 2018 (has links)
Em cumprimento aos requisitos normativos e regulatórios, considerados os padrões nacionais e internacionais de Boas Práticas de Fabricação (BPF) de medicamentos, o ambiente de produção de radiofármacos (célula) é determinante para a qualidade do medicamento, quanto aos limites estabelecidos na legislação vigente para níveis de contaminantes, discriminados como partículas não viáveis (partículas em geral) e microrganismos viáveis, corroborado, ainda, pelo fator de decaimento radioativo, uma vez que os radiofármacos devem ser liberados e administrados aos pacientes pouco tempo após sua produção. Tão importante quanto proteger o produto contra uma possível contaminação do meio ambiente é o operador estar protegido contra a contaminação pelo manuseio do produto. Assim, o estudo, concepção e desenvolvimento de uma célula nacional implicou em análises minuciosas de cada um dos elementos de composição do ambiente de produção e de sua operação, orientado pelo conceito de Quality by Design, metodologia que vem sendo aplicada, recentemente, na indústria farmacêutica. O conhecimento do produto, a configuração do espaço de operação por meio de mockup, a abordagem quanto aos atributos críticos da qualidade, com definições claras quanto aos parâmetros do processo produtivo, validados em experimentos, definiram uma célula multipropósito para produção de radiofármacos em acordo com BPF. / In order to fulfill the normative and regulations requirements under the national and international aspects of Good Manufacturing Practices (GMP), the radiopharmaceutical production environment (called \"hot cell\") is determinant for the quality of the medicinal product, within the limits established by the current legislation for levels of contaminants, split into non-viable particles (airborne general particles) and viable microorganisms; in addition to the radioactive decay (called \"half-life\") results radiopharmaceuticals to be released and administered to patients shortly after their production. It is not sufficient to protect the product against possible contamination from the environment, but the operator must be contamination protected when handling the product. Thus, the study, design and development of a national hot cell resulted in detailed analyzes of each single elements of the production environment and its operation, guided by the concept of Quality by Design, which is the methodology that has been applied recently at the pharmaceutical industry. The features such as the product conceptual knowledge, the configuration of the operating space (by mockups), the approaches regarding the quality critical attributes, the clear definitions regarding the parameters of the productive process, and finally the experimental validation, defined a multipurpose hot cell for the production of radiopharmaceuticals according to GMP requirements.
56

Estudo, desenvolvimento e construção de célula multipropósito para produção de radiofármacos, em acordo com parâmetros e padrões de Boas Práticas de Fabricação (BPF) / Study, development and assembling of a multipurpose hot cell for radiopharmaceuticals production in accordance with the Good Manufacturing Practices (GMP) requirements

Fábio Eduardo de Campos 10 December 2018 (has links)
Em cumprimento aos requisitos normativos e regulatórios, considerados os padrões nacionais e internacionais de Boas Práticas de Fabricação (BPF) de medicamentos, o ambiente de produção de radiofármacos (célula) é determinante para a qualidade do medicamento, quanto aos limites estabelecidos na legislação vigente para níveis de contaminantes, discriminados como partículas não viáveis (partículas em geral) e microrganismos viáveis, corroborado, ainda, pelo fator de decaimento radioativo, uma vez que os radiofármacos devem ser liberados e administrados aos pacientes pouco tempo após sua produção. Tão importante quanto proteger o produto contra uma possível contaminação do meio ambiente é o operador estar protegido contra a contaminação pelo manuseio do produto. Assim, o estudo, concepção e desenvolvimento de uma célula nacional implicou em análises minuciosas de cada um dos elementos de composição do ambiente de produção e de sua operação, orientado pelo conceito de Quality by Design, metodologia que vem sendo aplicada, recentemente, na indústria farmacêutica. O conhecimento do produto, a configuração do espaço de operação por meio de mockup, a abordagem quanto aos atributos críticos da qualidade, com definições claras quanto aos parâmetros do processo produtivo, validados em experimentos, definiram uma célula multipropósito para produção de radiofármacos em acordo com BPF. / In order to fulfill the normative and regulations requirements under the national and international aspects of Good Manufacturing Practices (GMP), the radiopharmaceutical production environment (called \"hot cell\") is determinant for the quality of the medicinal product, within the limits established by the current legislation for levels of contaminants, split into non-viable particles (airborne general particles) and viable microorganisms; in addition to the radioactive decay (called \"half-life\") results radiopharmaceuticals to be released and administered to patients shortly after their production. It is not sufficient to protect the product against possible contamination from the environment, but the operator must be contamination protected when handling the product. Thus, the study, design and development of a national hot cell resulted in detailed analyzes of each single elements of the production environment and its operation, guided by the concept of Quality by Design, which is the methodology that has been applied recently at the pharmaceutical industry. The features such as the product conceptual knowledge, the configuration of the operating space (by mockups), the approaches regarding the quality critical attributes, the clear definitions regarding the parameters of the productive process, and finally the experimental validation, defined a multipurpose hot cell for the production of radiopharmaceuticals according to GMP requirements.

Page generated in 0.0581 seconds