Spelling suggestions: "subject:"reuso dde água."" "subject:"reuso dee água.""
111 |
Avaliação da qualidade virológica do efluente doméstico tratado e disponibilizado para reúso na cidade de São Paulo. / Evaluation of virological quality of treated wastewater available for urban reuse in Sao Paulo city.Garrafa, Patricia 25 May 2009 (has links)
O objetivo deste estudo foi avaliar a qualidade virológica da água de reúso produzida em uma das estações de tratamento de esgoto da cidade de São Paulo. Para tanto, foram coletadas concomitantemente 177 amostras de esgoto tratado (100L) e bruto (15L) e os vírus concentrados utilizando método Viradel-ultracentrifugação. Em seguida as amostras foram tratadas com Vertrel XF e os ácidos nucléicos extraídos para a detecção de adenovírus (HAdV), rotavírus (RV-A), norovírus e vírus da hepatite A (VHA). A detecção por PCR e/ou RT-PCR evidenciou RV-A (G1-G5), VHA e HAdV incluindo os da espécie F tanto no esgoto bruto quanto no tratado, no entanto norovírus não foram detectados em ambos os efluentes. A infectividade de RV-A e HAdV foi avaliada por cultivo celular e os rotavírus RV-A foram também quantificados por reação de imunoperoxidase direta. PCR em tempo real foi padronizada para quantificação de vírus não cultiváveis ou de difícil cultivo como os VHA. Com base nos resultados obtidos foi verificada a ocorrência e a distribuição anual de cada vírus nas águas de reúso. / The aim of the study was to evaluate the virological quality from one Sewage Treatment Plant in the state of São Paulo. From January/2005 to November/2006, 177 samples (15L) of raw sewage were collected at the entrance and another 177 (100L) at the end of treatment, twice a week. Viruses were concentrated by filtration through positively charged microporous filters, followed by ultracentrifugation. Virus concentrates were treated by using Vertrel-XF and the viral genomes extracted for detection of adenovirus (HAdV), rotavirus (RV-A), norovirus and hepatitis A virus (HAV). PCR and RT-PCR revealed RV-A (G1-G5), HAV and HAdV, including the enteric ones (species F) in sewage and treated wastewater samples. Norovirus was not detected in any samples. The infectivity of HAdV and RV-A was assayed by inoculating onto suitable cell line. Immunoperoxidase assay was used to calculate the rotavirus FFU/L in the samples. Real time-PCR was standardized for enumeration of non-cultivable virus. The occurrence and annual distribution of each virus in reuse water were analyzed.
|
112 |
Análise ambiental, energética e econômica de arranjo processual para reúso de água em refinaria de petróleo. / Environmental, energetic and economic analysis of a process design for water reuse in petroleum refinery.Gripp, Victor Sette 18 December 2013 (has links)
Foi construído um modelo representativo do ciclo de vida da água em uma refinaria de petróleo, contemplando todos os usos a que esta se presta. Nesse contexto foram avaliados do ponto de vista ambiental, energético e econômico cenários em que etapas adicionais eram incorporadas ao tratamento de efluentes de forma a viabilizar o reúso de água e o fechamento do circuito na própria refinaria, reduzindo assim a necessidade de captação e, consequentemente, de tratamento da água bruta captada pela refinaria. O Cenário I corresponde ao cenário-base, sem implantação de nenhuma ação voltada ao reúso. No Cenário II, é incorporada a etapa adicional chamada Tratamento Fase 1, constituída por um processo de Clarificação seguido de uma Eletrodiálise Reversa (EDR) que permite o reúso de 255,7 m3/h dos 350 m3/h lançados inicialmente ao corpo hídrico no Cenário I. No Cenário III, é incorporada ao arranjo do Cenário II uma etapa de Cristalização Evaporativa para tratar o concentrado salino da EDR, recuperando, assim, mais 55,4 m3/h dos 350 m3/h lançados inicialmente, utilizando, para isso, vapor residual inicialmente não aproveitado pela refinaria. A análise ambiental foi desenvolvida por Avaliação do Ciclo de Vida (ACV) e constatou um desempenho muito semelhante dos três cenários. Apesar disso, a análise em perfil aberto, de impactos de midpoint, evidenciou ganhos ambientais significativos associados ao fechamento de circuito de água e, embora com vantagens muito discretas, o Cenário III apresentou um desempenho superior ao do Cenário II em todas as categorias e, na grande maioria delas, também superior ao desempenho do Cenário I. A análise de indicador único, em endpoint, destacou o impacto em Mudança Climática, relativo principalmente à queima de gás natural na caldeira para a geração de vapor, como o principal impacto ambiental associado ao ciclo de vida da água na refinaria, responsável por mais de 90% do valor correspondente ao resultado do indicador único. A análise energética foi desenvolvida utilizando-se o indicador de Demanda Cumulativa de Energia (CED) e resultou em um desempenho superior do Cenário I, ainda que com pequenas diferenças em relação aos Cenários II e III. O pior desempenho foi o do Cenário II. Comparando-se a contribuição relativa dos diferentes tipos de energia, destaca-se a energia de origem hidrelétrica, responsável por cerca de 80% do indicador único de CED em todos os três cenários. A análise econômica foi realizada por meio de indicadores tradicionalmente utilizados para a análise de viabilidade de projetos Taxa Interna de Retorno (TIR) e Valor Presente Líquido (VPL) , considerando, como referência, as regras de cobrança pelo uso da água vigentes na bacia do rio Paraíba do Sul. Com os preços cobrados atualmente pelo uso da água desta bacia, a implantação de ambos os cenários de reúso (II e III) não se viabiliza economicamente. Para que isso ocorra, o valor cobrado pelo uso da água teria que ser da ordem de 50 a 80 vezes maior do que o que é cobrado atualmente. Dentre os cenários de reúso, o Cenário II apresentou desempenho econômico superior ao do Cenário III. / It was built a representative model of the water life cycle within a petroleum refinery, considering all the uses in which it is applied. In this context, under environmental, energetic and economic perspective, different scenarios were analyzed, where further treatment stages were added to the wastewater treatment process so that recycled water could be provided back to the refining process, reducing, therefore, the need for freshwater intake and pretreatment by the refinery. Scenario I is the base scenario, without implementation of any water reuse aimed action. In Scenario II, it is incorporated the additional stage called Phase 1 Treatment, which consists of a Clarification process followed by an Electrodialysis Reversal (EDR).This enables the recycling of 255.7 m3/h from the 350 m3/h previously discharged to the water body in Scenario I. In Scenario III, it is incorporated to the Scenario II setting an Evaporative Crystallization process for treating the concentrated brine resulting from the EDR process. This enables the recovery of more 55.4 m3/h from the 350 m3/h initially released, using, for that, the energy from residual steam previously not used by the refinery. The environmental analysis was developed through Life Cycle Assessment (LCA) and found very similar performances for all three scenarios. Despite that, the open profile analysis, of midpoint impacts, showed significant environmental gains from the closure of the water circuit and, though with very small advantages, Scenario III showed a better performance than Scenario II in all impact categories and, in most of them, also better than Scenario I performance. The single score analysis, considering endpoint impact categories, highlighted Climate Change, specially related to the natural gas burning in the boiler for steam generation, as the main impact category associated to the water life cycle within the refinery, being responsible for more than 90% of all the value of the single score indicator. The energetic analysis was developed using the Cumulative Energy Demand (CED) indicator and resulted in a better performance of Scenario I, even if with just small differences from Scenarios II and III. The worst performance was from Scenario II. Comparing the relative contribution of the different types of energy, the hydroelectricity was the most important one, being responsible for around 80% of the CED single score in all three scenarios. The economic analysis was developed through traditional indicators used for assessing projects viability Internal Return Rate (IRR) and Net Present Value (NPV), considering, as reference, the rules of charging for water use valid nowadays at the Paraíba do Sul river basin. With the prices charged nowadays for the water use from this basin, the implementation of both reuse scenarios is not economic viable. In order to make it viable, the charged value would have to be around 50 to 80 times higher than it is today. Among the reuse scenarios, Scenario II had a better economic performance than Scenario III.
|
113 |
Avaliação de um sistema de tratamento de águas cinzas em edificação de campus universitário / Evaluation of a greywater treatment system in a building of university campusChrispim, Mariana Cardoso 01 September 2014 (has links)
O reúso de água é um instrumento importante que contribui para a redução da pressão sobre os mananciais e para redução do consumo de água potável para fins que não requeiram água de padrão potável. Neste contexto, o presente estudo teve como objetivo principal analisar um sistema de coleta e tratamento de águas cinzas provenientes de pias de banheiro, chuveiros e máquina de lavar roupas tendo em vista o reúso não-potável em edificações. Os objetivos específicos foram: caracterizar qualitativamente e quantitativamente as frações de águas cinzas; operar e monitorar um sistema de tratamento de águas cinzas sintéticas em escala piloto e analisar o efluente após tratamento. A partir de uma edificação existente no campus da EACH/USP, adaptou-se a estrutura hidráulica de forma a permitir a segregação e coleta desta fração de águas residuárias para caracterização e tratamento. A instalação de hidrômetros nas tubulações de alimentação dos pontos de uso (máquina de lavar, chuveiros e lavatórios) possibilitou analisar a produção de águas cinzas individualizada. Para o tratamento em escala piloto, adotou-se um biorreator de leito móvel com biofilme (MBBR) seguido por decantador. A avaliação do sistema de tratamento foi realizada com base no monitoramento periódico dos parâmetros físico-químicos durante o período de operação do sistema. Com base nos resultados obtidos, dentre as três frações de águas cinzas, a do chuveiro foi a que apresentou maior concentração de E.coli, enquanto que a maior concentração de coliformes totais foi na água cinza de lavatórios. As eficiências de remoção de DBO e DQO foram de 59 por cento e 70 por cento respectivamente. Houve baixa remoção de fósforo e não houve remoção de Nitrogênio Total durante o tratamento. / Water reuse is an important tool that can contribute to the reduction of the pressures from human activities on water resources and to reduce the demand for potable water for purposes that do not require high quality water. Therefore, the main objective of this study was to evaluate a greywater collection and treatment system from lavatories, showers and washing machine aiming the non-potable reuse in buildings. The specific objectives were: to characterize in terms of quality and quantity the greywater from each source, to monitor a pilot system for synthetic greywater treatment and to analyze the quality of the effluent after treatment. In an existing building in the University of Sao Paulo campus, the wastewater collection drains were modified to allow the segregated wastewater collection and the greywater characterization and treatment. To evaluate the greywater generation three water flow meters were installed in water inlet of each greywater source (washing machine, showers and lavatories). The greywater treatment included a moving bed biofilm reactor (MBBR) and a settling tank at pilot scale. The evaluation of greywater treatment was conducted based on the periodic monitoring of several physicochemical water quality parameters during the operation of the experimental system. Based on the results, amongst the three greywater sources, the greywater from showers had the highest E. coli count while the lavatories greywater had the highest total coliforms count. The removal efficiencies of BOD and COD were 59 per cent e 70 per cent respectively. In addition there was low removal of phosphorus and there was not Total Nitrogen Removal during the treatment.
|
114 |
Água: economia e uso eficiente no meio urbano / Water: economy and efficient use in urban environmentFranco Junior, Reynaldo Silveira 22 August 2007 (has links)
A água é um elemento vital para a vida, e em especial para a vida dos homens, os problemas causados pelo crescimento populacional e pelas mudanças de hábitos nas cidades, influenciam de forma determinante no estado das águas". Volumes cada vez maiores de água são captados diariamente para o uso agrícola, industrial e urbano e uma vez utilizados são lançados ao meio ambiente. Muitas vezes transportam elementos contaminantes, esgoto doméstico e industrial, produtos químicos, metais pesados, e poluição difusa ausando impactos negativos imprevisíveis. Em muitos paises no mundo e o Brasil em regiões do semi-árido nordestino, e em especial nas regiões metropolitanas de São Paulo e Rio de Janeiro, um crescente déficit hídrico, impõe novas soluções de abastecimento de água. Este estudo busca soluções para um uso mais racional da água, um uso mais eficiente e que traga a economia de um bem cada vez mais precioso. Como mecanismos de economia de água, estudamos os dispositivos de micro-drenagem, a utilização de água da chuva para fins domésticos não potáveis. A adoção de mecanismos de reúso e de reciclagem da água, em atividades que permitam a utilização de uma água de menor qualidade, também são importantes ferramentas para a economia da água. Outra forma de utilização eficiente da água é o uso da água proveniente do rebaixamento dos lençóis freáticos para construção de 4 subsolos em edifícios, estes volumes, que em geral são diretamente bombeados e descartados na rede pluvial urbana, representam grande economia quando usados para fins não potáveis. Por fim uma análise dos aspectos jurídicos que condicionam o reúso da água. / Water is a vital element for life, especially for the human race. The problems caused by population growth and changes of habits in cities have a great influence in the state of water supply" Increasing volumes of water are seized daily for agricultural, industrial and urban use and returned to the environment after that. Many times these water wastes have contaminating elements, industrial and residential sewage, chemical products, heavy metals and diffuse pollution that cause negative impacts of unknown intensity. In many countries and in Brazils semi-arid northeast region and, especially in the metropolitan areas of São Paulo and Rio de Janeiro a increasing deficit of water supplies call for new solutions in water supplying systems. The present study seeks for methods of rational use of water in an efficient way, in order to preserve an increasingly precious asset. The mechanisms for water saving studied in this dissertation are micro drainage systems and the use of rainwater for non-drinkable water uses. Adopting mechanisms of reuse and recycling of water in activities that can withstand the use of water of lower standards of quality are also important tools for water supply saving. Another method of efficient use of water is the use of undercurrent waters disposed for the construction of underground floors in buildings. These sources are usually pumped and discarded in the urban drainage systems, and if properly used for non-drinking purposes could help save great volumes of water. The study also includes an analysis of the juridical aspects that regulate water reuse.
|
115 |
Irrigação com efluente de esgoto tratado na cultura da laranja: implicações nas propriedades físicas e químicas de um argissolo vermelho amarelo distrófico típico / Irrigação com efluente de esgoto tratado na cultura da laranja: implicações nas propriedades físicas e químicas de um ARGISSOLO VERMELHO AMARELO distrófico típicoSilva, Marcos Schaaf Teixeira da 19 May 2009 (has links)
A crise da água, o aumento de esgoto domésticos gerado em estações de tratamentos e o despejo destes efluentes em corpos d\'água vêm sugerindo novas soluções para esses problemas. A disposição de água residuária tratada em solos implica na reciclagem de matéria orgânica e dos nutrientes, atuando como um processo complementar ao tratamento dessas águas. Rica em nutrientes principalmente N (nitrogênio), P (fósforo) e Na (sódio), a água residual tratada vem sendo utilizada na agricultura, utilizando critérios técnicos, como fonte de nutrientes para diversas culturas. Diante deste contexto, o objetivo deste trabalho foi analisar os possíveis efeitos da irrigação com efluente tratado em algumas propriedades químicas e físicas de um solo cultivado com laranja. A área experimental esta situada ao lado da Estação de Tratamento de Esgoto (ETE) do Ribeirão Piracicamirim que se localiza nas margens da rodovia \"Luiz de Queiroz\" no município de Piracicaba-SP. Os tratamentos aplicados foram relacionados ao percentual de umidade da capacidade de campo variando em T100%, T125%, T150%, T200% e TSI (tratamento sem irrigação). O delineamento experimental utilizado foi o de blocos inteiramente casualizados com parcelas subdivididas no tempo, com três repetições. A adubação realizada foi a de metade da dose recomendada para a cultura da laranja. Em todo o estudo as amostragens de solo foram realizadas nas camadas 0-10, 10-20, 20-40, 40-60, 60-80 e 80-100, enquanto que as amostragens de solução do solo foram realizadas nas profundidades 30, 100 e 200 cm. As variáveis químicas determinadas no solo foram: pH, H + Al, Al, Na, K, Ca e Mg. Em solução do solo as variáveis determinadas foram: pH, CE, Al, Na, K, Ca e Mg. As variáveis físicas determinadas foram: fração granulométrica e grau de dispersão de argilas. O efluente de esgoto tratado (EET) utilizado apresenta baixas concentrações de Ca, Mg, Na, K, Al, CE e RAS quando comparado com valores encontrados na literatura. Por esse fato, o EET apresenta menor potencial de alterações nas propriedades químicas e físicas do solo. O teor de sódio trocável e PST aumentaram no decorrer do experimento, enquanto a concentração de sódio na solução do solo diminuiu. O cálcio trocável no solo sofreu diminuição dos teores nas camadas superficiais, e aumento nas camadas subsuperficias. As perspectivas da irrigação de efluente de esgoto tratado na cultura da laranja são promissoras, haja vista a importância da cultura no cenário brasileiro e mundial. No entanto, estudos de longo prazo são necessários a fim de monitorar os possíveis impactos que a irrigação de EET possa ocasionar na estrutura do solo. / The crisis of the water, the sewage domestic increase generated in stations of treatments and the spilling of these effluents in bodies of water are suggesting new solutions for those problems. The disposition of wastewater treated in soils implicate in the nutrient and organic matter recycling, acting as a complementary process to the treatment of those waters. Rich in nutrients mainly N (Nitrogen), P (Phosphorus) and Na (Sodium) the treated wastewater has been used in the agriculture through technical criteria as source of nutrients for several crops. Before this context, the objective of this work was to analyze the possible effects of the irrigation with effluent treated in some chemical and physical properties of a soil cultivated with Orange. The experimental area located her beside the Station of Sewage Treatment (SST) Piracicamirim that is located in the margins of the highway \"Luiz de Queiroz\" in the municipal district of Piracicaba, São Paulo State. The applied treatments were related to the percentile of humidity of the field capacity varying in T100%, T125%, T150%, T200% and TSI (treatment without irrigation). The experimental design was a split plot scheme of randomized blocks subdivided in time, with five treatments and three repetitions. The accomplished fertilization was the one of half of the dose recommends for the orange crop. In whole the study the soil samplings were accomplished in the layers 0-10, 10-20, 20-40, 40-60, 60-80 and 80-100, while the samplings of soil solution were accomplished in the depths 30, 100 and 200 cm. The chemical variables determined in the soil were pH, H + Al, Al, Na, K, Ca and Mg. In soil solution the variables were pH, CE, Al, Na, K, Ca and Mg. The certain physical variables were fraction particle sizing and degree of clay dispersion. The sewage effluent treated (SET) used presents low concentrations of Ca, Mg, In the, K, Al, CE and RAS when compared with values found in the literature. For that fact, SET present potential minor of alterations in the chemical and physical properties of the soil. The exchangeable sodium and PST increased in elapsing of the experiment, while the concentration of sodium in the soil solution decreased. The exchangeable calcium in the soil suffered decrease in the superficial layers, and increase in the subsuperficial layers. The perspectives of the irrigation of SET in the orange crop are promising, have seen the importance of the culture in the Brazilian and world scenery. However, it is suggested studies of long period in order to monitor the possible impacts to cause in the structure of the soil.
|
116 |
Osmose inversa aplicada no reúso da água do rio Sarapuí em processos industriais / Reverse osmosis applied in Sarapuí river water reuse in industrial processesRaphael da Rocha Sixel 14 December 2009 (has links)
O objetivo deste estudo foi analisar o desempenho de um sistema de captação e tratamento de água do rio Sarapuí, por meio de uma estação de tratamento composta por um sistema de pré-tratamento convencional, ligado a um sistema de separação por membranas de osmose inversa, no Município de Belford Roxo RJ, instalado para fornecer água de processo a instalações industriais. Foi verificado que a água captada encontra-se em condição bastante degradada e que a unidade de tratamento removeu, em média, 97% do teor dos poluentes presentes na água, enquadrando-a nos parâmetros requeridos pelo processo industrial. Foi possível comprovar que o processo de separação por osmose inversa pode ser utilizado em escala industrial, proporcionando ganhos econômicos consideráveis, além de evitar o consumo de água potável para fins de processos industriais e, ainda, contribuir para a retirada de carga orgânica de uma fonte degradada / The objective of this study was to analyze the performance of a system to capture and treat water from Sarapuí river through a treatment system consisting of a conventional pré-treatment stage, linked to a reverse osmosis separation system membranes, in the city of Belford Roxo - RJ, installed to provide process water for industrial plants. It was found that the water is captured in highly degraded condition and the treatment plant removed an average of 97% of the pollutants in the water, fitting the parameters required by the industrial process. It could be demonstrated that the separation process by reverse osmosis can be used on an industrial scale, providing significant economic gains, and avoid the consumption of potable water for industrial processes and also contribute to the removal of organic pollutants from a degraded source
|
117 |
Avaliação de um sistema de tratamento de águas cinzas em edificação de campus universitário / Evaluation of a greywater treatment system in a building of university campusMariana Cardoso Chrispim 01 September 2014 (has links)
O reúso de água é um instrumento importante que contribui para a redução da pressão sobre os mananciais e para redução do consumo de água potável para fins que não requeiram água de padrão potável. Neste contexto, o presente estudo teve como objetivo principal analisar um sistema de coleta e tratamento de águas cinzas provenientes de pias de banheiro, chuveiros e máquina de lavar roupas tendo em vista o reúso não-potável em edificações. Os objetivos específicos foram: caracterizar qualitativamente e quantitativamente as frações de águas cinzas; operar e monitorar um sistema de tratamento de águas cinzas sintéticas em escala piloto e analisar o efluente após tratamento. A partir de uma edificação existente no campus da EACH/USP, adaptou-se a estrutura hidráulica de forma a permitir a segregação e coleta desta fração de águas residuárias para caracterização e tratamento. A instalação de hidrômetros nas tubulações de alimentação dos pontos de uso (máquina de lavar, chuveiros e lavatórios) possibilitou analisar a produção de águas cinzas individualizada. Para o tratamento em escala piloto, adotou-se um biorreator de leito móvel com biofilme (MBBR) seguido por decantador. A avaliação do sistema de tratamento foi realizada com base no monitoramento periódico dos parâmetros físico-químicos durante o período de operação do sistema. Com base nos resultados obtidos, dentre as três frações de águas cinzas, a do chuveiro foi a que apresentou maior concentração de E.coli, enquanto que a maior concentração de coliformes totais foi na água cinza de lavatórios. As eficiências de remoção de DBO e DQO foram de 59 por cento e 70 por cento respectivamente. Houve baixa remoção de fósforo e não houve remoção de Nitrogênio Total durante o tratamento. / Water reuse is an important tool that can contribute to the reduction of the pressures from human activities on water resources and to reduce the demand for potable water for purposes that do not require high quality water. Therefore, the main objective of this study was to evaluate a greywater collection and treatment system from lavatories, showers and washing machine aiming the non-potable reuse in buildings. The specific objectives were: to characterize in terms of quality and quantity the greywater from each source, to monitor a pilot system for synthetic greywater treatment and to analyze the quality of the effluent after treatment. In an existing building in the University of Sao Paulo campus, the wastewater collection drains were modified to allow the segregated wastewater collection and the greywater characterization and treatment. To evaluate the greywater generation three water flow meters were installed in water inlet of each greywater source (washing machine, showers and lavatories). The greywater treatment included a moving bed biofilm reactor (MBBR) and a settling tank at pilot scale. The evaluation of greywater treatment was conducted based on the periodic monitoring of several physicochemical water quality parameters during the operation of the experimental system. Based on the results, amongst the three greywater sources, the greywater from showers had the highest E. coli count while the lavatories greywater had the highest total coliforms count. The removal efficiencies of BOD and COD were 59 per cent e 70 per cent respectively. In addition there was low removal of phosphorus and there was not Total Nitrogen Removal during the treatment.
|
118 |
Reciclagem de água e nutrientes pela irrigação da cana-de-açúcar com efluente de estação de tratamento de esgoto / Water and nutrients recycling by sugarcane irrigation with sewage treatment plant effluentMagnus Dall'Igna Deon 15 June 2010 (has links)
A cultura da cana-de-açúcar, pelo alto consumo de água e de nutrientes, além da destinação industrial, apresenta características ideais para o recebimento de efluente de estações de tratamento de esgoto (EETE) sob a forma de irrigação. Esta prática tem como objetivo a reciclagem de nutrientes e de água, o incremento da produtividade e a economia de fertilizantes, de terra arável e de água potável. Apesar das múltiplas vantagens ambientais, não é desprovida de riscos, e este trabalho teve como objetivos avaliar a dinâmica de nutrientes no sistema solo-planta de canavial irrigado com efluente de esgoto tratado em dois ciclos consecutivos da cana-soca e a influência do aporte de nutrientes e outros elementos via efluente sobre a nutrição mineral da canade- açúcar. Foram aplicadas lâminas de irrigação com o esgoto tratado entre 0 (sem irrigação) e 200 % da exigência de água pela cultura, em gotejamento subsuperficial. Foram avaliados os aportes de nutrientes e outros elementos pelo efluente, os efeitos na composição nutricional da planta e da fração trocável do solo e o desempenho quantitativo e qualitativo da cultura. Concluiu-se que o efluente pode fornecer até 163 kg ha-1 de N; 14 kg ha-1 P; 145 kg ha-1 de K; 80 kg ha-1 de Ca; 28 kg ha-1 de Mg; 207 kg ha-1 de S; 0,45 kg ha-1 de B; 0,07 kg ha-1 de Cu; 0,25 kg ha-1 de Fe e 0,18 kg ha-1 de Mn, sendo fonte potencial de nutrientes à cultura da cana-de-açúcar, principalmente N, Ca e S, precisando de complementação mineral de P, K, Mg e micronutrientes. O estado nutricional da cultura, avaliado pela diagnose foliar melhorou para N, Mg, S e Cu no segundo ano avaliado. A folha +1 foi mais sensível às alterações de disponibilidade de nutrientes. A presença de elementos no efluente que podem potencialmente provocar degradação nas propriedades físicas do solo, tal como o sódio, contaminação de águas subterrâneas, como o nitrogênio, ou ainda tóxicos, como cromo e cobre, exige monitoramento constante da área agrícola que recebe este resíduo. Neste trabalho de curto prazo, estes elementos não representaram problemas. A irrigação com EETE proporcionou aumento do desempenho vegetativo da cultura e um ganho de produtividade na cana-de-açúcar de até 19,84 e 40,47 Mg ha-1, na primeira e na segunda socas, respectivamente. A qualidade industrial da cana-de-açúcar não foi alterada significativamente pela irrigação com EETE. Este trabalho mostrou que a irrigação com EETE é exequível, possui potencial econômico e seria uma solução possível para parte da demanda agrícola de água e dos problemas de poluição dos corpos dágua naturais. / Sugarcane cultivation, due to the high water and nutrients consumption, besides the industrial utilization, has ideal characteristics for receiving sewage treatment plant effluent (STPE) as irrigation. This practice aims to recycle nutrients and water, increasing productivity and decreasing the use of fertilizers, agricultural land and potable water. Despite the many environmental benefits, it has risks, and this study aimed to evaluate the dynamics of nutrients in the soil-sugarcane plant system irrigated with treated sewage effluent in two consecutive sugarcane ratoon cycles and the influence of nutrient and other elements added as effluent on the sugarcane mineral nutrition. Irrigations with treated sewage were applied up to 200% of the crop water requirement by subsurface drip. Nutrient and other elements input by the effluent, its effect on plant nutritional composition, soil exchangeable fraction and the quantitative and qualitative sugarcane performance were evaluated. Effluent can provide up to 163 kg ha-1 N, 14 kg ha-1 P, 145 kg ha-1 K, 80 kg ha-1 Ca, 28 kg ha-1 Mg, 207 kg ha-1 S, 0.45 kg ha-1 B, 0.07 kg ha-1 Cu, 0.25 kg ha-1 Fe and 0.18 kg ha-1 Mn, being a potential source of N, Ca and S, needing additional P, K, Mg and micronutrients fertilization. Sugarcane nutritional status as assessed by foliar analysis was improved for N, Mg, S and Cu in the second ratoon evaluated. Top visible dewlap leaf was more sensitive to changes in the nutrients availability. The presence of elements in the effluent that can potentially cause degradation in soil physical properties, such as sodium, groundwater contamination, such as nitrogen, or toxic substances, such as chromium and copper, requires constant monitoring of the agricultural area that receives this residue. In these short-term experiments there were no such problems. The replacement of crop evapotranspiration by irrigation with STPE provided an increase in vegetative performance and a gain in productivity of the sugarcane by 19.84 and 40.47 Mg ha-1, in the first and in the second ratoon, respectively. Industrial quality of sugarcane was not significantly affected by irrigation with STPE. This study showed that irrigation with STPE is potentially feasible, has economic potential, and would be a possible solution to part of the agricultural water demand and natural water bodies pollution problems
|
119 |
Água: economia e uso eficiente no meio urbano / Water: economy and efficient use in urban environmentReynaldo Silveira Franco Junior 22 August 2007 (has links)
A água é um elemento vital para a vida, e em especial para a vida dos homens, os problemas causados pelo crescimento populacional e pelas mudanças de hábitos nas cidades, influenciam de forma determinante no estado das águas. Volumes cada vez maiores de água são captados diariamente para o uso agrícola, industrial e urbano e uma vez utilizados são lançados ao meio ambiente. Muitas vezes transportam elementos contaminantes, esgoto doméstico e industrial, produtos químicos, metais pesados, e poluição difusa ausando impactos negativos imprevisíveis. Em muitos paises no mundo e o Brasil em regiões do semi-árido nordestino, e em especial nas regiões metropolitanas de São Paulo e Rio de Janeiro, um crescente déficit hídrico, impõe novas soluções de abastecimento de água. Este estudo busca soluções para um uso mais racional da água, um uso mais eficiente e que traga a economia de um bem cada vez mais precioso. Como mecanismos de economia de água, estudamos os dispositivos de micro-drenagem, a utilização de água da chuva para fins domésticos não potáveis. A adoção de mecanismos de reúso e de reciclagem da água, em atividades que permitam a utilização de uma água de menor qualidade, também são importantes ferramentas para a economia da água. Outra forma de utilização eficiente da água é o uso da água proveniente do rebaixamento dos lençóis freáticos para construção de 4 subsolos em edifícios, estes volumes, que em geral são diretamente bombeados e descartados na rede pluvial urbana, representam grande economia quando usados para fins não potáveis. Por fim uma análise dos aspectos jurídicos que condicionam o reúso da água. / Water is a vital element for life, especially for the human race. The problems caused by population growth and changes of habits in cities have a great influence in the state of water supply Increasing volumes of water are seized daily for agricultural, industrial and urban use and returned to the environment after that. Many times these water wastes have contaminating elements, industrial and residential sewage, chemical products, heavy metals and diffuse pollution that cause negative impacts of unknown intensity. In many countries and in Brazils semi-arid northeast region and, especially in the metropolitan areas of São Paulo and Rio de Janeiro a increasing deficit of water supplies call for new solutions in water supplying systems. The present study seeks for methods of rational use of water in an efficient way, in order to preserve an increasingly precious asset. The mechanisms for water saving studied in this dissertation are micro drainage systems and the use of rainwater for non-drinkable water uses. Adopting mechanisms of reuse and recycling of water in activities that can withstand the use of water of lower standards of quality are also important tools for water supply saving. Another method of efficient use of water is the use of undercurrent waters disposed for the construction of underground floors in buildings. These sources are usually pumped and discarded in the urban drainage systems, and if properly used for non-drinking purposes could help save great volumes of water. The study also includes an analysis of the juridical aspects that regulate water reuse.
|
120 |
Avaliação da qualidade virológica do efluente doméstico tratado e disponibilizado para reúso na cidade de São Paulo. / Evaluation of virological quality of treated wastewater available for urban reuse in Sao Paulo city.Patricia Garrafa 25 May 2009 (has links)
O objetivo deste estudo foi avaliar a qualidade virológica da água de reúso produzida em uma das estações de tratamento de esgoto da cidade de São Paulo. Para tanto, foram coletadas concomitantemente 177 amostras de esgoto tratado (100L) e bruto (15L) e os vírus concentrados utilizando método Viradel-ultracentrifugação. Em seguida as amostras foram tratadas com Vertrel XF e os ácidos nucléicos extraídos para a detecção de adenovírus (HAdV), rotavírus (RV-A), norovírus e vírus da hepatite A (VHA). A detecção por PCR e/ou RT-PCR evidenciou RV-A (G1-G5), VHA e HAdV incluindo os da espécie F tanto no esgoto bruto quanto no tratado, no entanto norovírus não foram detectados em ambos os efluentes. A infectividade de RV-A e HAdV foi avaliada por cultivo celular e os rotavírus RV-A foram também quantificados por reação de imunoperoxidase direta. PCR em tempo real foi padronizada para quantificação de vírus não cultiváveis ou de difícil cultivo como os VHA. Com base nos resultados obtidos foi verificada a ocorrência e a distribuição anual de cada vírus nas águas de reúso. / The aim of the study was to evaluate the virological quality from one Sewage Treatment Plant in the state of São Paulo. From January/2005 to November/2006, 177 samples (15L) of raw sewage were collected at the entrance and another 177 (100L) at the end of treatment, twice a week. Viruses were concentrated by filtration through positively charged microporous filters, followed by ultracentrifugation. Virus concentrates were treated by using Vertrel-XF and the viral genomes extracted for detection of adenovirus (HAdV), rotavirus (RV-A), norovirus and hepatitis A virus (HAV). PCR and RT-PCR revealed RV-A (G1-G5), HAV and HAdV, including the enteric ones (species F) in sewage and treated wastewater samples. Norovirus was not detected in any samples. The infectivity of HAdV and RV-A was assayed by inoculating onto suitable cell line. Immunoperoxidase assay was used to calculate the rotavirus FFU/L in the samples. Real time-PCR was standardized for enumeration of non-cultivable virus. The occurrence and annual distribution of each virus in reuse water were analyzed.
|
Page generated in 0.0826 seconds