21 |
In vivo evaluations of the neutralizing effect of a hydroxyl ion-releasing resin composite and a prophylactic gel on plaque acidogenicity : measured by the microtouch methodPersson, Anitha January 2006 (has links)
The prevalence of dental caries has decreased dramatically in most developed countries since the sixties and the number of remaining teeth in adults has increased during the last decades. Elderly as a group will during aging become an increasing risk group for caries. Especially older individuals with hyposalivation are at increased risk for coronal and root caries and need increased oral care. A large part of the time spent by the dental team is occupied by prevention and treatment of secondary caries, which is the main reason of replacement or repair of restorations. Traditionally, prevention of caries is directed against the different risk factors of the individual such as oral hygiene, intake of fermentable carbohydrates, cariogenic microflora and oral dryness. In some restorative materials the release of fluoride can be used to decrease the risk of secondary caries alone or in combination with other preventive methods. New alternative preventive methods are necessary to complete traditional methods in order to decrease the caries risk in elderly and/or to prevent secondary caries. Addition of methods with buffering properties have been suggested and developed to supplement the biological buffering capacity of saliva. The neutralizing effects of a hydroxyl ion-releasing resin composite and a prophylactic gel containing buffering properties on dental plaque acidogenicity was evaluated by the microtouch method. In this method, a skin reference electrode was validated in comparison with a glass capillary reference electrode and used in the subsequent studies. Change of plaque acidogenicity on proximal surfaces of aged restorations of the hydroxyl ion-releasing resin composite was compared intra-individually a conventional hybrid resin composite and a non-filled enamel proximal surface. Relative frequencies of cariogenic microorganisms in plaque on these surfaces were studied. The effect of a single application of the prophylactic gel with buffering substances was evaluated on plaque acidogenicity in healthy individuals with low and normal salivary secretion rate. It was compared intra-individually with the same gel without buffering substances. The effect of multiple applications of the prophylactic gel on plaque acidogenicity was studied in institutionalized elderly individuals with subjectively reported oral dryness and compared intra-individually with the same gel without buffering substances. Major results and conclusions from the studies are: • The use of the skin reference electrode, in combination with the microtouch electrode, showed high validity in comparison with the conventional glass capillary reference electrode • The hydroxyl ion-releasing composite resin countered plaque acidogenicity fall at two time points of the aged restorations and maintained it at levels where lesser demineralization occurs. No influence of the ion-release on the amount of cariogenic plaque microorganisms on the resin composite surface was observed • A single application of the prophylactic gel with buffering substances showed a neutralizing effect of plaque pH in healthy individuals with normal salivary secretion rate. No effect was observed in low secretion rate individuals. • Multiple applications of the prophylactic gel did not neutralize dental plaque acidogenicity in elderly individuals with subjective oral dryness
|
22 |
Proliferation of Pathogenic Biofilms within Sealer-root Dentin Interfaces is Affected by Sealer Type and Aging PeriodRoth, Karina Adriana 20 December 2011 (has links)
Objective: To assess biofilm proliferation within the sealer-dentin interfaces of methacrylate resin-based sealers, self-etch (SE) and total-etch (TE), and an epoxy resin-based sealer (EP). Methods: Standardized human root specimens were filled with the test materials and were aged for 1 week, 1, 3 or 6 months in saline (n=3/group). Monoclonal biofilms of Enterococcus faecalis were grown on the specimens for 7 days in continuous media reactor. The extent of biofilm proliferation of E. faecalis within the sealer-dentin interface for each material at each incubation period was assessed using fluorescence microscopy of dihydroethidium-stained specimens. Results: TE had less biofilm proliferation than EP and SE (p<0.01). Deeper biofilm proliferation was detected in SE and EP specimens aged for 1 and 3 months than those aged for 1 week or 6 months (p<0.05). Conclusion: Self-etch and epoxy resin-based sealers were more susceptible to interfacial biofilm proliferation than total-etch system at shorter incubation periods.
|
23 |
Proliferation of Pathogenic Biofilms within Sealer-root Dentin Interfaces is Affected by Sealer Type and Aging PeriodRoth, Karina Adriana 20 December 2011 (has links)
Objective: To assess biofilm proliferation within the sealer-dentin interfaces of methacrylate resin-based sealers, self-etch (SE) and total-etch (TE), and an epoxy resin-based sealer (EP). Methods: Standardized human root specimens were filled with the test materials and were aged for 1 week, 1, 3 or 6 months in saline (n=3/group). Monoclonal biofilms of Enterococcus faecalis were grown on the specimens for 7 days in continuous media reactor. The extent of biofilm proliferation of E. faecalis within the sealer-dentin interface for each material at each incubation period was assessed using fluorescence microscopy of dihydroethidium-stained specimens. Results: TE had less biofilm proliferation than EP and SE (p<0.01). Deeper biofilm proliferation was detected in SE and EP specimens aged for 1 and 3 months than those aged for 1 week or 6 months (p<0.05). Conclusion: Self-etch and epoxy resin-based sealers were more susceptible to interfacial biofilm proliferation than total-etch system at shorter incubation periods.
|
24 |
Avaliação da influência da técnica de fotopolimerização da resina composta e diferentes materiais protetores pulpares na formação de fendas /Souza, Niélli Caetano de. January 2007 (has links)
Resumo: O objetivo deste estudo foi avaliar a influência da fotopolimerização gradual no deslocamento de materiais protetores pulpares em função da contração de polimerização da resina composta através da formação de microfendas nas interfaces: estrutura dental/material protetor pulpar/ resina composta. Cavidades classe V, com dimensões padronizadas foram preparadas nas faces V e L de 20 terceiros molares humanos, divididos em 4 grupos de acordo com o material protetor pulpar e técnica de fotopolimerização: (1) Ketac Molar Easymix, 3M ESPE - (IVQ) + Fotopolimerização convencional - 850mW/cmø por 20s (FC); (2) IVQ + Fotopolimerização gradual - 100 mW/cm2 até 1000 mW/cm2 por 10s e 1000 mW/cm2 por 10s (FG); (3) Vitrebond 3M ESPE (IVR) + FC; (4) IVR +FG. Todas as cavidades foram restauradas com sistema adesivo Single Bond (3M ESPE) e resina composta híbrida Four Seasons (Ivoclar Vivadent). O aparelho fotopolimerizador utizado foi Optilux 501 (Demetron - Kerr) no modo convenciona e gradual (RAMP). Após ciclagem térmica um segmento longitudinal de 2 mm de espessura foi obtido na porção central de cada restauração e, em seguida, submetidos às etapas de fixação e desidratação em grau ascendente de etanol. A adaptação interna dos materiais à parede axial foi analisada em MEV, com 1000x de magnificação. A análise estatística realizada pela ANOVA a dois critérios de avaliação e pelos testes de Levene e Shapiro-Wilk (p_0,05) mostrou haver significância estatística entre as técnicas de fotopolimerização convencional e gradual (Ramp). Há evidência de que a fotopolimerização convencional produz, em 13 média, fendas maiores do que a fotopolimerização gradual. / Abstract: The aim of this study was to evaluate the influence of gradual photolymerization on the displacement of pulp protective materials due to the resinþs photopolymerization contraction trough the formation of gaps on the following interfaces: dental structure/ pulp protective material/ composite resin. Class V cavities with standardized dimensions were prepared on the buccal and lingual surfaces of 20 human sound third molars, divided into 4 groups according to their pulp protective material and photopolymerization technique:(1) Ketac Molar Easymix, 3M ESPE- (IVQ) + Conventional photopolymerization-850 mW/cm2 for 20 seconds (FC); (2) IVQ + gradual photopolymerization-100 mW/cm2 to 1000 mW/CM2 for 10 seconds and 1000 Mw/CM2 for 10 seconds (FG); (3) Vitrebond 3M ESPE (IVR)+ FC; (4) IVR + FG.All cavities were restored using the adhesive system Single Bond (3M ESPE) and hybrid composite resin Four Seasons (Ivoclar Vivadent). The device used for photopolymerization was the Optilux 501 (Demetron-Kerr) in both conventional and gradual (RAMP) modes. After thermal cycling, a longitudinal segment of 2 mm of thickness was obtained from the central part of every restoration, and submitted to fixation and dehydration with uprising levels of ethanol processes. The internal adaptation of the materials to the axial wall of the preparation was analyzed in 16 SEM with 1,000x of magnification. The statistical analysis was made using two-way ANOVA and Levene and Shapiro-Wilk (p _ 0,05) tests. Results showed statistically significant differences between the gradual (RAMP) and conventional photopolymerization techniques. There are evidences that the conventional technique creates wider gaps than the gradual technique. / Orientador: Alexandre Henrique Susin / Coorientador: Osmir Batista de Oliveira Junior / Banca: Marcelo Ferrarezi de Andrade / Banca: Roselaine Terezinha Pozzobon / Doutor
|
25 |
Longevidade de restaurações adesivas após a remoção total ou parcial de tecido cariado : estudo retrospectivo em dentes permanentes jovens da clínica da graduação e do curso de especialização em odontopediatria da FO-UFRGSTejeda Seminario, Alejandra January 2015 (has links)
Objetivo: Avaliar a longevidade e os possíveis fatores associados com as falhas de procedimentos restauradores adesivos diretos realizados em molares permanentes jovens portadores de lesões cariosas ativas profundas em dentina submetidos a remoção parcial (RPTC) ou total (RTTC) de tecido cariado. Métodos: A amostra de tipo censo foi composta por restaurações adesivas realizadas em molares permanentes jovens portadores de lesões cariosas ativas profundas em dentina submetidos à RPTC ou RTTC por alunos dos Cursos de Graduação e de Especialização em Odontopediatria da FO-UFRGS, Porto Alegre - RS. Foram avaliados possíveis fatores associados à sobrevida destas restaurações, tais como experiência de cárie (CPOD), índices de placa visível (IPV) e sangramento gengival (ISG), número de superfícies restauradas, nível de formação académica dos operadores e materiais capeadores e restauradores. Foi utilizada uma Curva de Sobrevida de Kaplan-Meier com teste de log-rank para analisar a longevidade das restaurações, e a Análise de regressão multivariada de Cox com fragilidade compartilhada para avaliar os fatores associados a falhas (p <0,05). Resultados: De 372 fichas clínicas, foram incluídos para análise 477 procedimentos restauradores adesivos realizados em 297 pacientes (9.14 1.75 anos). A sobrevida das restaurações alcançou um índice de 57,9% em até 36 meses de acompanhamento, com uma taxa de falha anual (TFA) de 16,7%. Não houve diferença estatisticamente significativa quando a RTTC ou a RPTC foi realizada (p = 0,163). O modelo ajustado mostrou que os pacientes com gengivite (ISG> 20%) apresentaram 2,88 vezes mais risco de falha em suas restaurações (p = 0,007). Restaurações com mais de duas superfícies envolvidas apresentaram 3 vezes mais risco de falha do que aquelas com uma única superfície, enquanto que as restaurações realizadas com cimento ionómero de vidro modificado por resina (CIVRM) apresentaram 4,11 vezes mais chance de falha do que as realizadas com resina composta (RC). Conclusão: O tipo de material restaurador, o número de superfícies restauradas e índice de sangramento gengival influenciaram na taxa de sobrevida das restaurações realizadas em lesões de cárie profunda em dentes permanentes jovens, independentemente da técnica de remoção de cárie utilizada. A falha restauradora, a qual foi determinada por uma subsequente anotação na ficha clínica de perda ou fratura da restauração, foi a principal causa de insucesso nos procedimentos restauradores adesivos, independentemente de ser removido ou não totalmente o tecido cariado. / Objective: To evaluate the longevity and factors associated with failures of restorations performed in permanent molars after complete (CCR) and partial caries removal (PCR). Methods: The sample was composed by adhesive restorations performed in deep caries lesion of permanent teeth that had been treated with CCR or PCR by undergraduate and graduate students in a public pediatric dental clinic. Factors such as caries experience (DMFT), visible plaque (VPI) and gingival bleeding (GBI) indexes, number of restored surfaces, type of capping and restorative materials were investigated. Kaplan–Meier survival curve with log-rank test was used to analyze the longevity of restorations. Multivariate Cox regression analysis with shared frailty was used to assess the factors associated with failures (p<0.05). Results: 477 restorations placed in 297 children (9.14 1.75 years) were included in the analysis. The survival of restorations reached 57.9% up to 36 months of follow-up, with overall annual failure rate) of 16.7%. There was no difference when CCR or PCR were performed (p=0.163). The adjusted model showed that patients presenting gingivitis (GBI>20%) have 2.88 times more risk of failure in their restorations (p=0.007). Multi-surface restorations showed a risk of failure more than 3 times higher than single-surface (p=0.003). Modified glass ionomer cement presented a risk of failure 4.11 times greater than composite resin (p<0.001). Conclusion: The type of restorative material, number of restored surfaces and gingivitis influenced the survival rate of restorations performed in deep carious lesion of young permanent teeth, independently of caries removal technique used.
|
26 |
Avaliação das fendas marginais em restaurações de resina composta com variação de alguns determinanates clínicos / Evaluation of marginal gaps in composite resin restorations with some variation of clinical determinantsMarco Antonio Gallito 28 April 2008 (has links)
O objetivo deste estudo foi comparar, por meio de mensuração das fendas na interface dentina - restauração de resina composta com utilização de algumas variáveis: fotoativação com lâmpada halógena e com LED; utilização de resina microhíbrida com partículas nanométricas Filtek Z350 ou sem estas partículas Filtek Z250; variação do sistema adesivo (Adper Single Bond 2 ou Adper Scotchbond Multi Purpose); variação da temperatura da resina composta; uso de dessensibilizante dentinário ou não; remoção do colágeno da dentina ou não e variação da intensidade de luz na fotoativação. Foram utilizados 70 molares humanos recém-extraídos, com cavidades circulares na dentina superficial de cada face proximal, foram divididos em 10 amostras para cada variável citada acima. Os dentes foram devidamente restaurados, seguindo as instruções dos fabricantes, para todos os grupos e mantidos em estufa bacteriológica por um período de 7 dias, após este período, foram polidos e as réplicas de resina epoxídica foram confeccionadas a partir de uma moldagem com silicone por adição, as mesmas foram levadas ao MEV, para a análise. As fendas foram mensuradas com o auxílio do software UTHSCSA Image tool e os dados foram submetidos à análise estatística pelo teste t de Student para a obtenção dos resultados. Com base nos resultados obtidos pode-se concluir que: os menores valores de fendas marginais foram obtidos quando da utilização de luz halógena (t=3,246 e p= 0,02) e com variação da intensidade desta luz (t= - 8,808 e p= 0,00). Os menores valores relativos de fendas, mas sem diferença estatística significante, foram encontrados, também, quando a resina Filtek Z350 foi comparada com a resina Filtek Z250 (t=-0,426 e p= 0,672) e quando o adesivo Adper Scotchbond Multi Purpose foi comparado com o Sistema Adper Single Bond 2 (t= 0,883 e p= 0,382). Os maiores valores de fendas marginais foram obtidos com a resina Filtek Z350 préaquecida a 60oC (t= -3,961 e p=0,000); com o uso de dessensibilizante dentinário (t=-3,062 e p=0,004) e com a remoção do colágeno pelo hipoclorito de sódio (t= -8,808 e p= 0,000). / The objective of this study was to compare through the cracks measurements in the dentin resin interface, using some variables: light activation with halogenic lamp and with LED; the use of micro-hybrid resin with or without nanofiller (Filtek Z350 anda Filtek Z250); variation of the adhesive systems (Adper Single Bond 2 or Scotchbond Multi Purpose); variation of the temperature in the compound resin; to use or not use the dentin desensitizing; to remove or not the dentin collagen and the light intensity variation in the light-curing. It was used 70 human extracted molars, with circular cavities in the superficial dentin of each proximal face; they were divided in 10 samples to each supra cited variable. The teeth were restored, followint the manufacturer instructions, and they were kept in a bacteriologtical kiln during a seven days period. After this time, the teeth were glossed, the resin replica were made from an addition silicone casting and these were took to the MEV, to be analyzed. The cracks were measured with the help of a UTHSCSA tool image software and the data were submited to an statistical analysis with the Student t test. The results obtained give the following conclusions: the lower values of marginal cracks were obtained when it was used the halogenic light (t = 3,246 and p = 0,02) and due the intensity variation of this light (t = 8,808 and p = 0,00). The lowest values related to the cracks were found when the Filtek Z350 resin was compared to the Filtek Z250 resin (t = 0,426 and p = 0,672), and when the Adper Scotchbond Multipurpose adhesive was compared with the Adper Single Bond 2 system (t = 0,883 and p = 0,382). The greatest values of marginal cracks were obtained with Filtek Z350 resin preheated at 60 degrees (t = -3,961 and p = 0,00); with the use of dentin desensitizing (t = -3,062 and p = 0,004) and with the removal of the collagen by using sodium hypochlorite (t = -8,808 and p = 0,000).
|
27 |
AVALIAÇÃO DA COR DE RESINAS COMPOSTAS EM MEIOS E TEMPOS DE ARMAZENAMENTO DISTINTOS USANDO DOIS ESPECTROFOTÔMETROS / COLOR EVALUATION OF RESIN COMPOSITES IN DIFFERENT MEANS AND TIMES OF STORAGE USING TWO SPECTROPHOTOMETERSDiesel, Pâmela Gutheil 07 February 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to evaluate the color of composite resins when stored in water and red wine, during different periods (immediately after polymerization, 24
hours, 30 days and 180 days) comparing the two measurements of spectrophotometers (Easyshade - Vita and SP60 - X-Rite). Four resin composites were used in two opacities (dentin and enamel): Filtek Supreme XT, Ice, and Opallis Brilliant. After confection 14 specimens (sp) for each resin composite using a metal matrix with 10 mm diameter and 2 mm thick, light cure with a LED (±800mW/cm2) by 40s, sp were polished with Sof-Lex Pop On and felt disc with diamond paste, washed with water and dried with gauze. Immediately after polishing, the initial measurement of the sp was performed, using the CIE L * a * b *. The sp of each composite resin were divided into two groups (n = 7) according to the storage media. Successive
readings were taken at 24h, 30 days and 180 days. The color change (ΔE) was calculated using the formula ΔE = ((ΔL)2 + (Δa)2 + (Δb)2)½. The data were subjected
to Student t Test and Pearson Linear Correlation for comparison of two spectrophotometers, and ANOVA and Tukey (5%) for each spectrophotometer. In both spectrophotometers, the resins immersed in red wine showed greater change than those kept in water and these values increased over time for most resins. For ΔE obtained by the SP60, the sp immersed in water remained stable, contrary to what was measured by Easyshade that had color changes over time. Although the values of ΔE measured at Easyshade and SP60 were significantly different, they
were highly correlated. / O objetivo deste trabalho foi avaliar a cor de resinas compostas quando armazenadas em água e em vinho tinto, durante períodos distintos (imediatamente após a fotoativação, 24h, 30 dias e 180 dias) comparando a leitura realizada por dois espectrofotômetros (Easyshade - Vita e SP60 - X-Rite). Foram utilizadas 4 resinas compostas em 2 opacidades (esmalte e dentina): Filtek Supreme XT, Ice, Brilliant e Opallis. Após a confecção de 14 corpos-de-prova (cps) para cada resina composta, utilizando uma matriz metálica com 10 mm de diâmetro e 2 mm de espessura,
fotoativados com um LED (±800mW/cm2), por 40s, os cps foram polidos com discos Sof-Lex Pop On e disco de feltro com pasta diamantada, lavados em água e secos
com gaze. Imediatamente após o polimento, foi feita a mensuração inicial dos cps nos dois aparelhos utilizando o sistema CIE L* a* b*. Os cps de cada resina composta foram divididos em dois grupos (n=7) de acordo com os meios de
armazenamento. Sucessivas leituras foram realizadas nos períodos de 24h, 30 dias e 180 dias. A alteração de cor (ΔE) foi calculada utilizando a formula ΔE = ((ΔL)2 +
(Δa)2 + (Δb)2)½. Os dados foram submetidos ao Teste t de Student e Correlação Linear de Pearson para comparação dos dois aparelhos e à Análise de Variância e Teste de Tukey (5%) para cada um dos aparelhos. Nos dois aparelhos, as resinas imersas em vinho tinto apresentaram maior alteração que as mantidas em água e esses valores aumentaram ao longo do tempo para a maioria das resinas. Para ΔE
obtidos pelo SP60, os cps mantidos em água mantiveram-se estáveis, ao contrário do que foi mesurado pelo Easyshade que teve alterações de cor com o passar do tempo. Embora os valores de ΔE mensurados pelo Easyshade e SP60 tenham sido significativamente diferentes, eles foram altamente correlacionados.
|
28 |
Avaliação da influência da técnica de fotopolimerização da resina composta e diferentes materiais protetores pulpares na formação de fendasSouza, Niélli Caetano de [UNESP] 01 February 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0
Previous issue date: 2007-02-01Bitstream added on 2014-06-13T21:02:28Z : No. of bitstreams: 1
souza_nc_me_arafo.pdf: 1115015 bytes, checksum: 8487455e45f6d12782f7b081be948890 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a influência da fotopolimerização gradual no deslocamento de materiais protetores pulpares em função da contração de polimerização da resina composta através da formação de microfendas nas interfaces: estrutura dental/material protetor pulpar/ resina composta. Cavidades classe V, com dimensões padronizadas foram preparadas nas faces V e L de 20 terceiros molares humanos, divididos em 4 grupos de acordo com o material protetor pulpar e técnica de fotopolimerização: (1) Ketac Molar Easymix, 3M ESPE - (IVQ) + Fotopolimerização convencional - 850mW/cmø por 20s (FC); (2) IVQ + Fotopolimerização gradual - 100 mW/cm2 até 1000 mW/cm2 por 10s e 1000 mW/cm2 por 10s (FG); (3) Vitrebond 3M ESPE (IVR) + FC; (4) IVR +FG. Todas as cavidades foram restauradas com sistema adesivo Single Bond (3M ESPE) e resina composta híbrida Four Seasons (Ivoclar Vivadent). O aparelho fotopolimerizador utizado foi Optilux 501 (Demetron - Kerr) no modo convenciona e gradual (RAMP). Após ciclagem térmica um segmento longitudinal de 2 mm de espessura foi obtido na porção central de cada restauração e, em seguida, submetidos às etapas de fixação e desidratação em grau ascendente de etanol. A adaptação interna dos materiais à parede axial foi analisada em MEV, com 1000x de magnificação. A análise estatística realizada pela ANOVA a dois critérios de avaliação e pelos testes de Levene e Shapiro-Wilk (p_0,05) mostrou haver significância estatística entre as técnicas de fotopolimerização convencional e gradual (Ramp). Há evidência de que a fotopolimerização convencional produz, em 13 média, fendas maiores do que a fotopolimerização gradual. / The aim of this study was to evaluate the influence of gradual photolymerization on the displacement of pulp protective materials due to the resinþs photopolymerization contraction trough the formation of gaps on the following interfaces: dental structure/ pulp protective material/ composite resin. Class V cavities with standardized dimensions were prepared on the buccal and lingual surfaces of 20 human sound third molars, divided into 4 groups according to their pulp protective material and photopolymerization technique:(1) Ketac Molar Easymix, 3M ESPE- (IVQ) + Conventional photopolymerization-850 mW/cm2 for 20 seconds (FC); (2) IVQ + gradual photopolymerization-100 mW/cm2 to 1000 mW/CM2 for 10 seconds and 1000 Mw/CM2 for 10 seconds (FG); (3) Vitrebond 3M ESPE (IVR)+ FC; (4) IVR + FG.All cavities were restored using the adhesive system Single Bond (3M ESPE) and hybrid composite resin Four Seasons (Ivoclar Vivadent). The device used for photopolymerization was the Optilux 501 (Demetron-Kerr) in both conventional and gradual (RAMP) modes. After thermal cycling, a longitudinal segment of 2 mm of thickness was obtained from the central part of every restoration, and submitted to fixation and dehydration with uprising levels of ethanol processes. The internal adaptation of the materials to the axial wall of the preparation was analyzed in 16 SEM with 1,000x of magnification. The statistical analysis was made using two-way ANOVA and Levene and Shapiro-Wilk (p _ 0,05) tests. Results showed statistically significant differences between the gradual (RAMP) and conventional photopolymerization techniques. There are evidences that the conventional technique creates wider gaps than the gradual technique.
|
29 |
Estudo da difusão de um corante orgânico em resinas compostas polimerizadas por duas fontes de luz : avaliação através de espectroscopia de fluorescência /Hidalgo de Andrade, Laura Elena. January 2004 (has links)
Resumo: A utilização de corantes fluorescentes tem ajudado ao estudo da penetração de sistemas adesivos na estrutura dental e alguns compósitos, bem como na avaliação da microinfiltração e fendas na interface dente restauração. No caso das resinas compostas, esta técnica pode ser útil na verificação da profundidade de polimerização e vulnerabilidade físico-química das mesmas a corantes orgânicos. Neste intuito, nos propusemos a avaliar por meio de espectroscopia de fluorescência, a difusão de um corante orgânico em resinas compostas em função dos fatores: 1. Tipo de resina, 2. Fonte de luz, 3. Tempo de polimerização e 4. Tempo de imersão no corante. Para isso, foram realizados 2 grupos experimentais de acordo com a fonte de luz: lâmpada halógena- Grupo H e sistema LEDs - Grupo L. Cada grupo foi subdividido de acordo com a resina utilizada: 1. Micropartícula (Filtek A110/ 3M), 2. Híbrida (Z100/ 3M) e 3. Compactável (P60/ 3M), onde cada subgrupo teve 2 tempos de polimerização: 40 e 60 segundos, e 3 tempos de imersão em solução de Rodamina 6G a 0,1% em etilenoglicol: 0, 24 e 48 horas. Cada subgrupo possuía 5 amostras de 4 mm de diâmetro e 4 mm de espessura. Completados os tempos de imersão, foi obtida 1 fatia de 1,5 mm de espessura de cada amostra, para traçar o perfil espacial de fluorescência e calcular o coeficiente de difusão. Os resultados mostraram que a resina híbrida obteve os menores valores de difusão quando comparada com as outras. Além disso houve uma tendência da difusão diminuir com o aumento do tempo de imersão de 24 para 48 horas, bem como com o aumento do tempo de polimerização de 40 para 60 segundos. A lâmpada halógena determinou difusão significantemente menor nos corpos de prova quando comparado com o sistema LEDs, independente do tipo de resina utilizada. Com isto, podemos concluir que a difusão de corante... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The fluorescent markers have been used to assess the teeth and composites bonding systems penetration, microleakeage and teeth-restoration interface gaps. This markers also can be used to verify the resin deep polimenization and organic dyes susceptibility. In this work, the fluorescence spectroscopy was used to assess an organic dye difussion on composite resins, considering: 1- resin type, 2- light source, 3- polimerization time and 4- dye immersion time. The experimental groups of Halogen lamp (group H) and LEDs system (group L) were sub-divided according to resin type: 1- microfilled (FilteK A110/3M), 2- hybrid (Z100/3M) and 3- packable (P60/3M) with 40 and 60 seconds of polimerization time, three immersion times on ethylene glycol rhodamine 6G 0.1% solution: 0, 24 and 48 hours, with 5 specimens for each sub-group (4 mm of diameter and thickness). Once completed the immersion times, one 1.5 mm slice was obtained for each specimen and spatial fluorescence profile was traced to calculate a difussion coeficient. The results shown that, compared to other resins, an hybrid resin has the lowest difussion values. When the immersion time was increased of 24 to 48 hours and polimerization time of 40 to 60 seconds, a difussion decrease tendency was observed. The specimens cured by halogen lamp shown significantly lower difussion than that cured by LEDs system, independent of resin type. We can conclude that dye difussion into resin mass was influencied by the same factors that affect the polimerization, and when lower polimerization was present, more quickly will be the dye difussion. / Orientador: Osmir Batista de Oliveira Júnior / Coorientador: Vanderlei Salvador Bagnato / Banca: Maria Salete Machado Cândido / Banca: José Roberto Cury Saad / Banca: João Carlos Gomes / Banca: Edson Alves de Campos / Doutor
|
30 |
Avaliação das fendas marginais em restaurações de resina composta com variação de alguns determinanates clínicos / Evaluation of marginal gaps in composite resin restorations with some variation of clinical determinantsMarco Antonio Gallito 28 April 2008 (has links)
O objetivo deste estudo foi comparar, por meio de mensuração das fendas na interface dentina - restauração de resina composta com utilização de algumas variáveis: fotoativação com lâmpada halógena e com LED; utilização de resina microhíbrida com partículas nanométricas Filtek Z350 ou sem estas partículas Filtek Z250; variação do sistema adesivo (Adper Single Bond 2 ou Adper Scotchbond Multi Purpose); variação da temperatura da resina composta; uso de dessensibilizante dentinário ou não; remoção do colágeno da dentina ou não e variação da intensidade de luz na fotoativação. Foram utilizados 70 molares humanos recém-extraídos, com cavidades circulares na dentina superficial de cada face proximal, foram divididos em 10 amostras para cada variável citada acima. Os dentes foram devidamente restaurados, seguindo as instruções dos fabricantes, para todos os grupos e mantidos em estufa bacteriológica por um período de 7 dias, após este período, foram polidos e as réplicas de resina epoxídica foram confeccionadas a partir de uma moldagem com silicone por adição, as mesmas foram levadas ao MEV, para a análise. As fendas foram mensuradas com o auxílio do software UTHSCSA Image tool e os dados foram submetidos à análise estatística pelo teste t de Student para a obtenção dos resultados. Com base nos resultados obtidos pode-se concluir que: os menores valores de fendas marginais foram obtidos quando da utilização de luz halógena (t=3,246 e p= 0,02) e com variação da intensidade desta luz (t= - 8,808 e p= 0,00). Os menores valores relativos de fendas, mas sem diferença estatística significante, foram encontrados, também, quando a resina Filtek Z350 foi comparada com a resina Filtek Z250 (t=-0,426 e p= 0,672) e quando o adesivo Adper Scotchbond Multi Purpose foi comparado com o Sistema Adper Single Bond 2 (t= 0,883 e p= 0,382). Os maiores valores de fendas marginais foram obtidos com a resina Filtek Z350 préaquecida a 60oC (t= -3,961 e p=0,000); com o uso de dessensibilizante dentinário (t=-3,062 e p=0,004) e com a remoção do colágeno pelo hipoclorito de sódio (t= -8,808 e p= 0,000). / The objective of this study was to compare through the cracks measurements in the dentin resin interface, using some variables: light activation with halogenic lamp and with LED; the use of micro-hybrid resin with or without nanofiller (Filtek Z350 anda Filtek Z250); variation of the adhesive systems (Adper Single Bond 2 or Scotchbond Multi Purpose); variation of the temperature in the compound resin; to use or not use the dentin desensitizing; to remove or not the dentin collagen and the light intensity variation in the light-curing. It was used 70 human extracted molars, with circular cavities in the superficial dentin of each proximal face; they were divided in 10 samples to each supra cited variable. The teeth were restored, followint the manufacturer instructions, and they were kept in a bacteriologtical kiln during a seven days period. After this time, the teeth were glossed, the resin replica were made from an addition silicone casting and these were took to the MEV, to be analyzed. The cracks were measured with the help of a UTHSCSA tool image software and the data were submited to an statistical analysis with the Student t test. The results obtained give the following conclusions: the lower values of marginal cracks were obtained when it was used the halogenic light (t = 3,246 and p = 0,02) and due the intensity variation of this light (t = 8,808 and p = 0,00). The lowest values related to the cracks were found when the Filtek Z350 resin was compared to the Filtek Z250 resin (t = 0,426 and p = 0,672), and when the Adper Scotchbond Multipurpose adhesive was compared with the Adper Single Bond 2 system (t = 0,883 and p = 0,382). The greatest values of marginal cracks were obtained with Filtek Z350 resin preheated at 60 degrees (t = -3,961 and p = 0,00); with the use of dentin desensitizing (t = -3,062 and p = 0,004) and with the removal of the collagen by using sodium hypochlorite (t = -8,808 and p = 0,000).
|
Page generated in 0.0674 seconds