• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 52
  • 11
  • 4
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 78
  • 78
  • 37
  • 35
  • 20
  • 16
  • 15
  • 14
  • 12
  • 12
  • 12
  • 11
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Avaliação da microdureza, rugosidade superficial e morfologia de dois compósitos submetidos ao clareamento dental e escovação simulada

Paulo Roberto Marão de Andrade Carvalho 17 July 2008 (has links)
O objetivo deste trabalho foi avaliar os efeitos da escovação com o uso de dentifrícios e tratamento clareador na superfície do compósito microhíbrido e nanoparticulado. Foram confeccionados corpos-de-prova com dimensões padronizadas (6 x 3 mm) das resinas Filtek Z-250 (microhíbrida, 3M/ESPE) e Filtek Z-350 (nanoparticulada, 3M/ESPE) (n= 120). Cada resina foi subdivida em seis tratamentos superficiais: controle (sem tratamento); tratamento clareador (Whiteness 16% - FGM); escovação com dentifrício convencional (Colgate Total 12); escovação com dentifrício clareador (Colgate Total 12 Whitening Gel - Palmolive); clareamento e escovação com dentifrício convencional e clareamento e escovação com dentifrício clareador. O tratamento clareador foi realizado durante quatro horas diárias por 15 dias. Após cada ciclo clareador, as amostras eram armazenadas em saliva artificial em estufa a 37 C até a próxima aplicação do gel clareador. Os grupos não clareados foram mantidos em saliva durante o experimento. Após o clareamento, foi realizada a escovação simulada (trinta mil ciclos) nos grupos préestabelecidos. Antes e após o clareamento e escovação, foi determinada a microdureza e rugosidade superficial dos compósitos. Duas amostras de cada grupo foram preparadas para observação em microscopia eletrônica de varredura (MEV). A rugosidade e microdureza obtida antes e após os tratamentos foram estatisticamente analisadas (ANOVA e Tukey/Kramer, p< 0,05). Inicialmente todos os grupos apresentaram valores de dureza e rugosidade semelhantes, entretanto, houve aumento da rugosidade da resina submetida à escovação e submetida ao clareamento associado à escovação com os dentifrícios A e B (p< 0,05). Não houve, todavia, alteração na microdureza superficial da resina Z350 após os tratamentos, enquanto o grupo 1 apresentou significante redução na dureza após o tratamento. Pode-se concluir que a escovação e o clareamento, em especial a associação destes, aumentam a rugosidade dos compósitos, mas não alteram a dureza da resina microhíbrida ou da nanoparticulada. / The aim of the present study was to evaluate the effects of simulated toothbrushing with dentifrices and bleaching treatment on the surface of microhybrid and nanofilled composites. Standardized samples (6x3 mm) Filtek Z-250 (microhybrid, 3M/ESPE) and Filtek Z-350 ( nanofilled, 3M/ESPE) were made (n= 120). Each composite was subdivided into six surface treatments: control (no treatment); bleaching treatment (Whiteness 16% - FGM); brushing with conventional dentifrice (Colgate Total 12); brushing with whitening dentifrice (Colgate Total 12 Whitening Gel Palmolive); bleaching and brushing with conventional dentifrice and bleaching and brushing with whitening dentifrice. Bleaching treatment was performed for four hours and 15 days. After each bleaching cycle, samples were stored in artificial saliva at 37 C until the next bleaching application. The non-bleached group remained stored in artificial saliva throughout all experiment. After bleaching, simulated toothbrush (thirty thousand cycles) were performed in the pre-established groups. Before and after bleaching and brushing, surface microhardness and roughness was performed on composite surface. Two samples of each group were prepared to scanning electron microscopy observation (SEM). Surface roughness and microhardness before and after treatments were statistically analyzed (ANOVA and Tukey/Kramer, p< 0,05). At baseline, all groups presented similar hardness and roughness values, however, there was a surface roughness increase on composite surface submitted to brushing and to bleaching associated to brushing with the dentifrices A and B (p< 0,05). On the other hand, there were not differences of the hardness of the Z350 composite after treatments, while 1 presented significant reduction of surface hardness after treatment. It could be concluded that brushing and bleaching, specially the association of both, increase composite surface roughness but do not alter surface microhardness of microhybrid and nanofilled composites.
42

Vliv povrchových úprav skleněných vláken na mechanickou odezvu GF/polyester kompozitu / The influence of surface modification of glass fibers on mechanical response of the GF/polyester composite

Janeček, Pavel January 2008 (has links)
The diploma thesis is aimed at an influence of surface modifications of fibrous reinforcements on mechanical properties at the fiber-matrix interface in fiber reinforced composites. Glass fibers were used as reinforcements and polyester resin was the matrix. The sample of composite consisted of polymer matrix in a form of cylindrical body placed on bundle of glass fibers. The design of the sample was constructed with respect to results of Finite Element Analysis (FEA). The tensile test using a materials testing machine (Zwick) was employed to evaluate adhesion at the fiber-matrix interface. Untreated glass fibers, fibers with commercial sizing, and fibers modified by deposition of plasma polymer film using Plasma-Enhanced Chemical Vapor Deposition (PECVD) at different deposition conditions were used for fabrication of composite samples. The fibers and composite samples were analyzed by Scanning Electron Microscopy (SEM) and Confocal Laser Scanning Microscopy (CLSM).
43

Randschlussuntersuchung von Kompositfüllungen unter Einfluss von Brauchwasserdesinfektionsmitteln zahnärztlicher Behandlungseinheiten / Border seal investigation on resin composite fillings under the influence of disinfectants of dental units

Fischer, Franziska 03 December 2013 (has links)
No description available.
44

Comparación in vitro de la estabilidad cromática de tres resinas compuestas inmersas a sustancias amazónicas / In vitro comparison of the color stability of three composite resins immerse in Amazonian substances

Acosta Zuñiga, Mirtha Pamela, Pineda Prado, Alejandra Priscila 05 January 2020 (has links)
Objetivo: Comparar la estabilidad cromática de tres tipos de resinas (Te-econom Plus®- Ivoclar Vivadent, Tetric® N- Ceram Bulk Fill -Ivoclar Vivadent, Filtek™ Bulk Fill - 3M) inmersas a sustancias amazónicas Myrciaria dubia (camu camu) y Mauritia flexuosa (aguaje).  Materiales y métodos: Se evaluaron 180 discos de resina (6mm de diámetro y 4mm de altura) de cada marca: Te-econom Plus®, Tetric® N- Ceram Bulk Fill, Filtek™ Bulk Fill color A2 divididas en 9 grupos inmersas a sustancias amazónicas, Myrciaria dubia (Camu Camu), Mauritia flexuosa (Aguaje) y agua destilada (Grupo control) por 30 días. Los especímenes fueron inmersos en 20 ml de sustancias diariamente a temperatura de 37 C±5°. La evaluación del color se realizó a los 7, 15 y 30 días, utilizando un espectrofotómetro Vita Easyshade® Advance 4.0, para hallar los valores de ΔE. Los resultados fueron realizados mediante estadística descriptiva e inferencial. Para el análisis univariado, se utilizó las medidas de tendencia central (media) y en las medidas de dispersión (desviación estándar). Para el análisis bivariado, se utilizó la prueba de Kruskal Wallis para comparar los valores de la estabilidad cromática de las tres resinas compuestas. Resultados: La resina Tetric® N- Ceram Bulk Fill presentó menores valores de ΔE en Mauritia flexuosa (5.06 ±2.1) y la resina Filtek™ Bulk Fill presentó mayores valores de ΔE en Myrciaria dubia (11.42 ± 3.83) a los 30 días, a diferencia de la resina Te-econom Plus® que sí presentó cambios significativos en ambas sustancias y en todos los tiempos (6.79 ± 0.67), (16.63±5.29), (11.75 ±6.57).  Conclusión: La Myrciaria dubia (Camu Camu) es la sustancia amazónica que presentó mayor valor de ΔE en las tres resinas compuestas y en los tres tiempos de evaluación. La resina Filtek™ Bulk Fill presentó mayor estabilidad cromática. La resina Te-econom Plus® presentó menor estabilidad cromática en las sustancias de inmersión en los tres tiempos establecidos. / Objective: to compare the color stability of three types of resins (Te-econom Plus® - Ivoclar Vivadent, Tetric® N- Ceram Bulk Fill -Ivoclar Vivadent, Filtek ™ Bulk Fill - 3M) immersed in Amazonian substances Myrciaria dubia and Mauritia flexuosa. Materials and methods: 180 resin discs (6mm in diameter and 4mm in height) of each brand were evaluated: Te-econom Plus® - Ivoclar Vivadent, Tetric® N- Ceram Bulk Fill -Ivoclar Vivadent, Filtek ™ Bulk Fill - 3M, divided into 9 groups immersed in Amazonian substances, Myrciaria dubia, Mauritia flexuosa and distilled water (Control group) for 30 days. The specimens were immersed in 20 ml of substances daily at a temperature of 37 ° C ± 5 °. The color evaluation was performed at 7 days, 15 days and 30 days, using a Vita Easyshade® Advance 4.0 spectrophotometer, to find the ΔE values. The results were performed using descriptive and inferential statistics. For univariate analysis, measures of central tendency(mean) and dispersion measures (standard deviation) were used. For the bivariate analysis, the Kruskal Wallis test was used to compare the chromatic stability values of the three composite resins.  Results: The Tetric® N-Ceram Bulk Fill resin had lower ΔE values in Mauritia Flexuosa (5.06 ± 2.1) and Filtek ™ Bulk Fill resin had higher ΔE values ​​in Myrciaria dubia (11.42 ± 3.83) at 30 days, unlike Te-econom Plus® resin that did show significant changes in both substances and at all times (6.79 ± 0.67), (16.63 ± 5.29), (11.75 ± 6.57). Conclusions: The Myrciaria dubia (Camu Camu) is the Amazonian substance that presented the highest value of ΔE in the three composite resins and in the three evaluation times. Filtek ™ Bulk Fill resin showed greater color stability. The Te-econom Plus® resin showed lower chromatic stability in the immersion substances in the three established times. / Tesis
45

Influence of curing-light beam profile non-uniformity on degree of conversion and micro-flexural strength of resin-matrix composite

Eshmawi, Yousef Tariq 05 October 2016 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Background. Beam profile non-uniformity of light-curing units (LCUs) may result in suboptimal properties of resin-matrix composite (RMC) restorations. Objectives: The objective of this study was to evaluate the effect of curing-light beam profile of multiple light curing units (LCUs) on the degree of conversion (DC) and micro-flexural strength (μ-flexural strength) of RMC. Methods: Forty-five nano-filled hybrid RMC (Tetric EvoCeram, Ivoclar Vivadent, Amherst, NY) specimens were fabricated. Quartz tungsten halogen (QTH) (Optilux 401) (O), multiple emission peak (VALO Cordless) (V) and single emission peak (Demi Ultra) (DU) light-emitting-diode (LED) LCUs were investigated at different light-curing locations (LCLs): 1) the center of the LCU tip; 2) 1.5 mm to the left of the center of the LCU tip; and 3) 1.5 mm to the right of the center of the LCU tip. Specimens were stored wet in deionized water at 37C for 24 hours. The DC was measured on top and bottom surfaces using Attenuated Total Reflectance-Fourier Transform Infrared (ATR-FTIR) spectroscopy. Micro-flexural strength testing was performed using a universal mechanical testing machine at crosshead speed of 1 mm/min. Multi-factorial ANOVAs were used to analyze the data (α = 0.05). Results: All LCUs exhibited significant differences in DC between top and bottom surfaces at the different LCLs. Micro-flexural strength varied with LCL for DU. Conclusions: The non-uniform curing-light beam profile could have a significant effect on μ-flexural strength and DC on top and bottom surfaces of RMC specimens cured at different LCLs.
46

Avaliação da microdureza de resina composta polimerizada com fontes de luz halógena e LED, em função da densidade de energia luminosa irradiada / Knoop hardness analisys of a resin composite activated by halogen lamp and LED, varying the luminous density

Pereira, Rosana Aparecida 08 July 2009 (has links)
No presente estudo, avaliou-se a microdureza da resina composta Z250 (3M ESPE), quando ativada em diferentes tempos (s), diferentes densidades de potência (mW/cm²), em relação à quantidade de energia irradiada (8, 12 e 16 J/cm²), com a finalidade de estabelecer uma densidade de energia luminosa mínima capaz de polimerizar adequadamente os compósitos. Foi utilizado um aparelho com fonte de luz halógena Degulux-Degussa, com 600 mW/cm² e dois aparelhos de fonte de luz LED, Ultraled XP (Dabi-Atlante) com 150 mW/cm² e LED Ultrablue-IS (DMC) com 300 mW/cm² e 600 mW/cm². Duas matrizes bipartidas de PTFE, de 1 e de 2 mm de espessura e um orifício central de 5 mm de diâmetro, foram usadas para confeccionar 60 corpos-de-prova, 5 em cada grupo. As duas partes da matriz foram contidas em um anel metálico com as mesmas espessuras. O material foi inserido na matriz e fotoativado de acordo com os diferentes tempos e a quantidade de densidade de energia luminosa para cada fonte de luz. Para obter os valores de microdureza Knoop, os espécimes foram levados ao microdurômetro Shimadzu HMV-2, com carga estática de 300 g por 5 segundos, para aferir as superfícies exposta (topo) e oposta (base) à fonte de luz, totalizando 120 medições. Os resultados foram submetidos aos testes ANOVA e Tukey, com nível de significância de 5%. Com os dados obtidos foi possível concluir que, com valores a partir de 16 J/cm² e 12 J/cm² de densidade de energia luminosa, espessuras de 2 mm de resina composta podem ser adequadamente polimerizadas utilizando-se fonte de luz halógena (600 mW/cm²) e LED (a partir de 300 mW/cm²) respectivamente. Contudo, estudos clínicos adicionais ainda são necessários para complementar este estudo / At this study it was evaluated the microhardness of the Z250 (3M ESPE) resin composite, when light cured for different periods of time (s), with different power densities (mW/cm²), related to the irradiated luminous energy density (8 J/cm², 12 J/cm² and 16 J/cm²), in order to establish a minimal energy density capable of adequately polymerize the composites. One halogen light curing unit Degulux- Degussa, with 600 mW/cm² of power density and two light-emitting diodes curing units Ultraled XP (Dabi-Atlante) with 150 mW/cm² and LED Ultrablue-IS (DMC) with 300 mW/cm² and 600 mW/cm² were used. Two bipartite PTFE matrices, with 1 and 2 mm of depth and a central orifice of 5 mm diameter, were used to make 60 specimens, 5 per group. The halves of the matrix were positioned inside a brass ring with both depths to prepare the specimens. The resin composite was inserted and light-activated according to the different periods and energy densities of each lightcuring unit. To evaluate Knoop microhardness, specimens were taken to a microdurometer Shimadzu HMV-2 with a static load of 300 g for 5 seconds, evaluating both exposed to light (surface) and opposite to light (base) exposition surfaces, totalizing 120 measurements. Results were submitted to ANOVA and Tukeys test with 5% significance level. Based on the obtained results, it was concluded that, starting from 16 J/cm² and 12 J/cm² of energy luminous density, 2 mm depth resin composite can be adequately polymerized utilizing halogen (600 mW/cm²) and LED ( starting from 300 mW/cm²) curing-units respectively. However, additional clinical studies are necessary to complement this investigation.
47

Influência de diferentes fontes fotoativadoras na resistência adesiva de restauração indireta de resina composta

Camilotti, Veridiana 15 December 2005 (has links)
Made available in DSpace on 2017-07-24T19:22:22Z (GMT). No. of bitstreams: 1 VeridianaCamilotti.pdf: 624713 bytes, checksum: f2d0756374875dd344e9aeeecdaac9cc (MD5) Previous issue date: 2005-12-15 / The following study aims to evaluate the influence between the different light sources in curing light of resin cement. The occlusal surfaces of twenty recently extractew undamaged third human molars were removed in order to expose dentine surface. Immediately after, the bond system (Adper Single Bond/3M ESPE ) and resin cement (RelyX ARC/ 3 M ESPE) was applied in accordance with manufacturer instructions. Second generation laboratory resin of 4 mm thickness was applied over tooth and light curing proceeded. According to light sources employed the teeth were divided in four groups: G1 – Control Optilux 401/ Demetron (QTH); G2 – L.E.Demetron/Demetron (LEDs ); G3 – Ultra-Lume LED5 (LEDs) e G4 – Optilight CL/ Gnatus (LEDs). Restored teeth were stored in physiologic serum for 24 h. After stored, teeth were sectioned into vestibule-tongue and mesial-distal to delimit an area with approximately 1 mm², the third cut was made on the base of the tooth in order to release the samples. The microtensile test was employed to reveal the bond strength values in MPa. The data underwent statistical analysis with p<0,05. No statistical significancent difference was found betweem the groups. In conclusion the resin cement bon strength of dual fotoative with LEDs showed similar adhesive resistance test those revelead when halogen lamp was used, and that there also were not differences among the different apparels LEDs used in that study. / Avaliou-se a influência de diferentes fontes de luz na fotoativação de um cimento resinoso dual. A superfície oclusal de 20 terceiros molares humanos hígidos foi removida para expor a superfície dentinária. Em seguida, foi aplicado sistema adesivo (Adper Single Bond/3M ESPE ) e cimento resinoso dual (RelyX ARC/ 3 M ESPE), de acordo com as recomendações do fabricante. A resina laboratorial de segunda geração (Gradia™ GC® América Inc), com espessura de 4 mm, foi adaptada sobre o dente e procedeu-se à fotoativação. De acordo com o aparelho de luz empregado, os elementos dentais foram divididos em 4 grupos: G1 – controle Optilux 401/ Demetron (QTH); G2 – L.E.Demetron 1/Demetron (LEDs ); G3 – Ultra- Lume LED5/Ultradent (LEDs) e G4 – Optilight CL/ Gnatus (LEDs). Os dentes restaurados foram armazenados em soro fisiológico por 24 h. Após o armazenamento, os dentes foram seccionados no sentido vestíbulo-lingual e mésiodistal, para delimitar uma área de 1 mm². Um terceiro corte na base do dente foi realizado com o objetivo de “soltar” os espécimes. O teste de micro-tração foi empregado para fornecer os valores da resistência adesiva em MPa. Os dados foram submetidos à análise estatística pelo teste ANOVA com p<0,05. Não houve diferenças estatisticamente significante entre os grupos testados. Concluiu-se que a resistência adesiva da interace adesiva fotoativado com LEDs foi semelhante à resistência adesiva obtida quando a lâmpada halógena foi utilizada e que também não houve diferenças entre os diferentes aparelhos LEDs empregados nesse estudo.
48

Longevidade e fatores associados à falha de restaurações adesivas de dentes decíduos / Longevity and factors associated with failure of adhesive restorations in primary teeth

Dalpian, Débora Martini January 2016 (has links)
O objetivo desta tese foi avaliar a longevidade e os fatores associados à falha de restaurações adesivas em dentes decíduos. Para isto, foram desenvolvidos dois estudos retrospectivos. No primeiro, foi feita a análise da longevidade de restaurações realizadas após a remoção seletiva de tecido cariado em dentes decíduos. Foram avaliados os prontuários de pacientes atendidos durante os anos de 2007 a 2012 no ambulatório de Odontopediatria da Universidade Federal do Rio Grande do Sul. Os critérios de inclusão previram a realização de pelo menos um procedimento de restauração com remoção seletiva de tecido cariado, em dente decíduo, e o acompanhamento clínico e/ou radiográfico. A amostra foi composta por 254 dentes de 118 pacientes, com período de acompanhamento de 1 a 50 meses. A sobrevida das restaurações, após 24 meses, foi de 51%, sendo constatada uma associação positiva entre a falha do procedimento e maiores valores do índice de placa visível (p=0.01). No segundo estudo, foi realizada uma avaliação da longevidade e dos fatores associados à falha de restaurações em dentes decíduos, após a remoção total e seletiva de tecido cariado. Para isso, foi desenvolvido um estudo retrospectivo, no curso de Odontologia do Centro Universitário Franciscano, com base nos prontuários de pacientes infantis, atendidos durante os anos de 2010 a 2016, que receberam pelo menos uma restauração em dente decíduo e tiveram um acompanhamento mínimo de seis meses. Foram incluídos 123 pacientes e 316 restaurações de resina composta ou cimento de ionômero de vidro. Após 3 anos, as restaurações apresentaram sobrevida de 54,4% e taxa de falha anual de 18,3%. A análise de Log-rank mostrou que a remoção seletiva de tecido cariado (p=0,03), o uso de base forradora de hidróxido de cálcio (p<0,01) e o cimento de ionômero de vidro (p=0,04) como material restaurador, resultaram numa menor sobrevida da restauração. A regressão de Cox ajustada demonstrou que restaurações realizadas com remoção seletiva de tecido cariado apresentam 3,41 (IC 95% 1,37;8,46) vezes maior risco de falha, quando comparadas à remoção total de tecido cariado. Conclui-se, então, que as restaurações em dentes decíduos, realizadas por alunos de graduação, possuem limitadas taxas de sobrevida e que fatores relacionados ao paciente e ao procedimento influenciam no desempenho da restauração. / The aim of this thesis was to evaluate the longevity and factors associated with failure of adhesive restorations in deciduous teeth. For this, two retrospective studies were carried out. In the first, the longevity of restorations performed after the partial removal of carious tissue in deciduous teeth was analyzed. The records of patients treated during the period from 2007 to 2012 were evaluated at the School of Dentistry, Federal University of Rio Grande do Sul. The inclusion criteria predicted the accomplishment of at least one restoration procedure with partial removal of carious tissue in deciduous tooth and clinical and / or radiographic follow-up. The sample consisted of 254 teeth from 118 patients with follow-up period from 1 to 50 months. The survival rate of restorations after 24 months was 51%, with positive association between procedure failure and higher visible plaque index values (p=0.01). In the second study, longevity and factors associated with failure of restorations in deciduous teeth after total and partial removal of carious tissue were evaluated. For that, a retrospective study was developed in the Dentistry course of the Franciscan University Center, based on the records of pediatric patients treated during the period from 2010 to 2016, who received at least one restoration in a deciduous tooth and had minimum follow-up of six months. The study included 123 patients and 316 composite resin or glass ionomer cement restorations. After 3 years, restorations presented survival rate of 54.4% and annual failure rate of 18.3%. The log-rank analysis showed that the partial removal of carious tissue (p= 0.03), the use of calcium hydroxide liner (p<0.01) and glass ionomer cement (p=0.04) as restorative material, resulted in shorter survival rate of restorations. Adjusted Cox regression showed that restorations performed with partial removal of carious tissue were 3.41 (95% CI 1.37-8.46) more likely of presenting greater risk of failure when compared to total removal of carious tissue. It could be concluded that restorations in deciduous teeth performed by undergraduate students have restricted survival rate and that factors related to patient and procedure influenced the performance of restorations.
49

Avaliação ex vivo da resistência à tração, de pinos metálicos em raízes fragilizadas tratadas com laser Er:YAG e reforçadas com resina composta / Tensile bond strength of metal posts after the application of Er:YAG laser treatment to the weakened root canal reinforced with composite resin

Santello, Luciana Cavali 07 February 2012 (has links)
O objetivo do estudo foi avaliar ex vivo a influência da aplicação do laser de Er:YAG na parede dentinária de raízes fragilizadas, reforçadas com resina composta. Cinquenta caninos superiores tiveram suas coroas removidas próximo da junção amelo-cementária e incluídas em bloco de resina acrílica. Após tratamento endodôntico foi realizada a fragilização das raízes. Os espécimes foram distribuídos aleatoriamente em 5 grupos (n=10),: Grupo I - não irradiado, tratado com ácido fosfórico 37%; Grupo II - irradiado com laser Er:YAG, 300mJ - 10 Hz; Grupo III - irradiado com laser Er:YAG, 300mJ - 10 Hz e tratado com ácido fosfórico 37% ;Grupo IV - irradiado com laser Er:YAG, 500mJ - 10 Hz; Grupo V - irradiado com laser Er:YAG, 500mJ - 10 Hz e tratado com ácido fosfórico 37%. Todos os espécimes receberem reforço intra-radicular com resina composta, foto-polimerizada por meio de pino foto-transmissor. No espaço promovido por este pino foi cimentado o pino metálico pré-fabricado, com cimento resinoso auto-adesivo de dupla polimerização. Os espécimes foram submetidos ao teste de Tração na Máquina Universal de Ensaios - INSTRON 4444. Os maiores valores para o deslocamento foram atribuídos ao Grupo I, estatisticamente semelhante ao Grupo III. Entretanto o Grupo III ocupa uma posição intermediária, podendo pertencer também aos GruposIV e V que foram estatisticamente semelhantes entre si e ao grupo II. / The aim of this study was to assess ex vivo the effects of Er:YAG laser as dentin treatment of weakened root canal reinforced with composite resin. Fifty upper canines were decoronated at cementoenamel junction and the roots were embedded in acrylic resin. After the endodontic treatment the roots were weakened and the specimens were randomly assigned to five groups (n=10): Group I - unirradiated, treated with phosphoric acid 37%; Group II - Er:YAG laser 300mJ - 10Hz; Group III - Er:YAG laser 300mJ - 10 Hz, treated with phosphoric acid 37%; Group IV - Er:YAG laser 500mJ - 10 Hz; Group V - Er:YAG laser 500mJ - 10 Hz, treated with phosphoric acid 37%. The intraradicular reinforcement was made in all specimens with composite resin using photo-transmitter post, which creates a space for the insertion of prefabricated metal post. The metal posts were inserted using a resin cement self-adhesive dual-cured. The tensile bond strength of specimens was tested in a universal testing machine - INSTRON 4444. The results showed that Group I was statistically similar to the Group III and presented the highest bond strength values. Group III also showed statistical similarity with Group IV and V, which were similar among them and the Group II.
50

Análise comparativa e caracterização das bolhas de ar em dois modelos de técnicas restauradoras: incremental e bulk fill / Comparative analysis of voids quantity in two restorative techniques: incremental and bulk fill

Díaz, Carolina Alejandra Pardo 05 December 2018 (has links)
Os materiais restauradores estão evoluindo rapidamente e novas técnicas de inserção do compósito na cavidade restauradora estão sendo propostos. Dependendo da técnica, poderá ocorrer maior ou menor formação de bolhas na restauração final. A incorporação de bolhas entre as camadas do material restaurador pode gerar uma maior degradação da restauração em virtude da menor obtenção de propriedades físico-mecânicas do material. Assim, a necessidade de estudos sobre a prevalência de bolhas em restaurações confeccionadas com diferentes técnicas de inserção se faz necessária para a melhor compreensão do uso e do manuseio dos materiais. O objetivo desse trabalho foi analisar a ocorrência de bolhas e o volume de espaços presentes no interior de restaurações com resina composta, inserida na cavidade dental através das técnicas restauradoras: incremental e bulk fill. Quarenta e oito dentes molares humanos (n=24, duas restaurações por dente) foram selecionados e, nestes, foram confeccionados dois preparos por dente, um em cada região proximal, com profundidade de 4mm, largura de 4mm e distância axio-proximal de 2mm. Posteriormente, foram restaurados de acordo com os grupos: FiltekTM One Bulk Fill Restorative (FOB; 3M Oral Care); FiltekTM Z350 XT (FXT; 3M Oral care); FiltekTM Bulk Fill Flowable Restorative (FBF+FXT; 3M Oral care) e FiltekTM Z350 XT Flow (FF+FXT; 3M Oral care) . As resinas fluidas foram cobertas com a resina FiltekTM Z350 XT (3M Oral Care). Após 24 horas, os dentes restaurados foram submetidos à ciclagem térmica (5.000 ciclos) e posteriormente foi realizada a Tomografia de Coerência Ótica (OCT). Através da análise das imagens obtidas pelo OCT foram medidos os valores de quantidade de bolhas e porcentagem de espaços presentes nas restaurações. Os dados da presença de bolhas foram analisados estatisticamente com o teste Qui-Quadrado, os dados de número de bolhas e porcentagem de espaços obtidos foram analisados com o teste de Kruskall Wallis e a comparação entre os grupos foi feita pelo método de Dunn , com nível de significância de 5%. FF+FXT, apresentou bolhas em todas as restaurações e foi significativamente maior quando comparado a FXT (p=0,015). FF+FXT apresentou quantidade significativamente maior de bolhas (p<0,05) quando comparada com os outros três grupos. FBF+FXT apresentou a maior porcentagem de porosidade, devido ao maior tamanho de bolhas, porém esta porcentagem foi significantemente maior apenas quando comparada com FXT (p<0,05). Todos os grupos apresentaram bolhas. As técnicas restauradoras que apresentaram o pior desempenho, considerando o número de bolhas e a porcentagem de porosidade, foram aquelas realizadas com resina composta fluída. Não houve diferença estatisticamente significante quanto ao número de bolhas e à porcentagem de espaços entre as restaurações confeccionadas somente com resinas de alta viscosidade para as diferentes técnicas utilizadas neste estudo. / Dental restorative materials are quickly evolving, and new techniques are being proposed to change the way of filling dental cavities. Depending on the technique, a different number of voids could be generated inside the restauration. The appearance of these voids between layers of resin composite can significate a greater degradation of the material determined by low mechanical and physical properties. Therefore, to investigate voids prevalence at different restorative techniques is needed, in order to get a better understanding of the resin composites and their best handling. The objective of this project was to analyze the voids frequency inside and between the layers of the resin composite, filling class II cavities using incremental technique and bulk fill technique. Forty eight human teeth (n=24, two restorations per tooth) were selected and two cavities per tooth were made, one per each proximal area, 4mm of depth, 4mm height and 2mm of axio-proximal distance. After, they were divided in four groups and restored using FiltekTM One Bulk Fill Restorative (FOB; 3M Oral Care); FiltekTM Z350 XT (FXT; 3M Oral care); FiltekTM Bulk Fill Flowable Restorative (FBF+FXT; 3M Oral care) e FiltekTM Z350 XT Flow (FF+F; 3M Oral care), handled according to manufacturer instructions. Flowable resin composite was covered with FiltekTM Z350 (3M Oral Care). 24 hours later, thermocycling was conducted (5,000 cycles) and later Optical Coherence Tomography was performed. By analyzing the OCT images, number of voids and percentage of void volume were calculated. Presence of voids were analyzed by Chi-squared test, number of voids and percentage of void volume were analyzed by Kruskall Wallis test, and comparisons were performed by Dunn Method, at significance level of 5%.. FF+FXT had voids in all the restorations of the group, and it was significantly greater when compared with FXT (p=0.015). FF+FXT had statistically significant more number of voids (p<0.05) when compared with the others 3 groups. FBF+FXT had the highest percentage of voids volume, because the size of its voids, but this percentage was significantly different only when compared with FXT (p<0,05). All groups had voids. Restorative techniques that presented worst performance, considering number of voids and percentage of voids volume, were the ones made with flowable resin composite. Non statistical differences referred to a number of voids, neither percentage of voids volume among restorations made using only high viscosity resin.

Page generated in 0.0971 seconds